Io UNITED STATES g

[

g NUCLEAR REGULATORY COMMISSION 4

E WASHINGTON, D. C. 20555 k.....,o April 23, 1985 Docket No. 50-323 MEMORANDUM FOR: Thomas M. Novak, Assistant Director for Licensing Division of Licensing FROM:

Dennis M. Crutchfield, Assistant Director for Safety Assessment Division of Licensing

SUBJECT:

DIABLO CANYON UNIT 2 FINAL DRAFT TECHNICAL SPECIFICATIONS The enclosed Technical Specifications for Diablo Canyon Unit 2 should be transmitted to the applicant for review and certification as being con-sistent with the FSAR, SER and as-built plant. The licensee should be requested to document in some detail the resources and process used to review and certify the Technical Specifications for issuance of an operating license for Diablo Canyon Unit 2.

The applicant had proposed technical specifications for Diablo Canyon Unit 2 by letter dated September 21, 1984 At the later re applicant the Standards and Special Projects Branch (SSPB) quest of the reviewed and updated those proposed technical specifications for issuance as combined Final Draft Technical Specifications for Diablo Canyon Units 1 and 2.

However, since inconsistencies between those specifications and the FSAR were thought to exist, by the Reactor System Branch, the Final Draft Spect-fications were not forwarded to the applicant for review and certification.

Rather, by my memorandum of December 17, 1934, the staff was asked to confirm that the proposed Final Draft Technical Specifications were acceptable.

Several connents by the staff were received. Our contractor EG&G provided comments by letter of January 30, 1985. Region V provided comments by memorandum dated January 16, 1985. By my memoranda to you dated March 6 and March 20, 1985 we forwarded 10 items of additional information needed for completion 'hf our technical specifications review. The applicant provided responses by its letters of April 11 and April 15, 1985.

All matters. identified by the staff review, the EG&G audit and by Region V have been resolved in an appropriate manner in the enclosed Final Draft Technical Specifications or deferred for resolution at the Full Power licensing stage by mutual agreement of all the parties involved.~,

CONTACT:

C. Moon 49-29786 r

b e-p

~

Y..

Thomas M. Novak 2-April 23, 1985 s

In response to your request, due to the time constraints of the Sholly Notice process the enclosed technical specifications are for Unit 2 only rather than combined technical specifications for Unit I and Unit 2.

Combined technical specifications for Units 1 and 2 will be prepared prior to full power licensing of Unit 2.

To provide assurance that the attached Technical Specifications accurately reflect the Diable Canyon FSAR, SER and Unit 2 as-built plant, we discussed all of these changes with representatives of the applicant at some length.

Therefore, we expect that the Technical Specifications that will be issued as Appendix A to the Diablo Canyon Unit 2 operating license will be identical to the attached version.

M Dennis 'M. Crute field,.ssis ant Director for Safety Assessme Division of Licensing

Enclosure:

Diablo Canyon Unit 2 Final Draft Technical Specifications 1

i f

4 O

%w'-emmiu"~%i-w MW & em W m'

A D*'

.-.e e-w-y

--9-i

--ww

-w gr.-

m

.m

.- w y y

-+. --

y 4.-

[

. If Sher bdf p'p** **%g$

y' UNITED STATES NUCLEAR REGULATORY COMMISSION

[

- WASHINGTON, D. C. 20005 T.

s **"* /

m e s es 9el > /4 DH ~ gzmf NN MEMORANDUM FOR: Albert Schwencer, Chief Licensing Branch #2-j Division of Licensing FROM:

William H. Regan, Jr., Acting Chief l

Human Factors Engineering Branch Division of Human Factors Safety 4

SUBJECT:

TECHNICAL EVALUATION REPORTS (TERs) FOR SALEM ATWS ITEM 1.2 (GENERIC LETTER 83-28)

Enclosed are 25 Salem ATWS Item 1.2 TERs covering the 37 units described in a memorandum from D. Beckham to F. Miraglia dated March 20, 1985. Additional information is required from the licensees so that we can provide closeout SERs to you by June 15, 1985. We have agreed that this information can be j

obtained by telecon.

l.

Please arrange for each Project Manager to transmit his/her TER to the licensee on an expedited schedule, indicating that the technical evaluation represents the staff's initial judgment and that the staff believes that open issues can be resolved by telecon. We should allow each licensee approximately five (5) working days to review the TER and prepare for the telecon.

My staff would like to complete all calls in a one-week time period, starting approximately May 20, 1985.

Each DL Project Manager should set up the telecon and include the Lead Project Manager, Mr. Bournia; the reviewer, Mr. Kramer; our contractor, and the Resident Inspector.

The TERs were prepared by our consultants from Science Applications j

International Corporation (SAIC). The staff agrees with the technical

]

content and conclusions of the contractor's reports. Please advise us when N

c~

Contact:

duck hk[(

gh cL j

J.Kramer x29853

$ %C c

$0h u

b CA D/ earm/,Q f

D ' " N U T IIC)

/t r

]

r b

i

_ _!?

\\1

j ',

g33g i.

Albert Schwencer, Chief the TERs have been sent to the licensees and when you have a preliminary-schedule for the phone calls.

Individual P.Ms should arrange their calls for either a~ morning or afternoon time period. Mr. Bournia could then coordinate specific ti,mes.

Yk

. Regan, J h,

ing Chief William Human Factors Engingerin ranch Division.of Human Fa4tors afety

Enclosure:

As stated cc:

T. Bournia R. Liner (SAIC)

D. Gallagher (SAIC) 4 h

e*

,,,p.,,y..

+uwe,...

=--

- + -

  • a

SAIC-85/iS14-1 REVIEW OF LICENSEE AND APPLICANT RESPONSES TO NRC GENERIC LETTER 83-28 (Required Actions. Based on Generic Implications of Salem ATWS Events), Item 1.2

-~

" POST-TRIP REVIEW: DATA AND INFORMATION CAPABILITIES" FOR DIABLO CANYON, UNIT 1 (50-275

)

l l

Technical Evaluation Report

~

Prepared by i

Science Applications International Corporation 1710 Goodridge Drive McLean, Virginia 22102 Prepared for U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Contract No. NRC-03-82-096

- - - + - -

w r

7, w,4-m S

,r

-9

[.

i

~~

FOREWORD.

This report contains the technical evaluation of the Diablo Canyon, Unit I response to Generic Letter 83-28 (Pequired Actions Based on Generic Implications of Salem ATWS Events)

Item 1.2 " Post Trip Review:

i Data and Information Capabilities."

For the purposes of this evaluation, the review criteria, presented in part 2 of this report, were divided into five separate categories. These are:

1.

The parameters monitored by.the sequence of events and the time 4

history recorders, i

4 2.

The performance characteristics of the sequence of events recorders, 3.

The performance characteristics of the time history recorders, 4.

The data output fomat, and 5.

The long-term data retention capability for post-trip review material.

All available responses to Generic Letter 83-28 were evaluated. The plant for which this report is applicable was found to have adequately responded to, and met, categories 2, 3, 4 and 5.

The report describes the specific methods used to determine the cate-goritation of the responses to Generic Letter 83-28.

Since this evaluation i

report was intended to apply to more than one nuclear power plant specifics regarding how each plant met (or' failed to meet) the requirements are not presented.

Instead, the evaluation presents a categorization of the responses according to which categories of requirements are satisfied and which are not.

The evaluations are based on specific criteria (Section 2) derived from the requirements as stated in the generic letter.

)

1 I

1

?

J

~-~~<+ -

-~r v.

y gi-y-+

g,

-w,.

wvy.i-,

,.,p, nn._y-

.g.g--,-

_..,_._m__

.,9,,y,,,..,

,,.,, v 99,,-wy,,

q

-,q,if

-7%.

-+.-y,p.,,,.a, g-9

-e.eee9 g.gy--

TABLE OF CONTENTS Section

~

Page Introduction.........................

1 1.

Background..........................

2 2.

Review Criteria.......................

3 3.

Evaluation..........................

8 4.

Conclusion..........................

8 5.

Re fe re nc e s..........................

10

(,. Conv1ms-docuwy pk),0 rnunciou.

tI

,. ~ -

c

.,m..,.

m.

g._.,

p q

y y

y

.w-9-wy e-

.,r

-eg.,

T 1

1 INTRODUCTION _

SAIChasreviewedthej fals prepared in response to Generic Letter 83-28, item 1.2 " Post-Trip Review:

Data and Information Capability".

The submittab (see references) contained sufficient information to determine that the data and information capabilities at this 11 ant are acceptable in the following areas.

e The sequence-of-events recorder (s) performance charac-teristics.

e The time history recorder (s) performance characteris-tics.

e The output format of the recorded data.

e The long-term data retention, record keeping, capa-bility.

However, the data and information capabilities, as described in the submittal, either fail to meet the review criteria or provide insufficient information to allow determination of the adequacy of the data and information capabilities in the following area.

e The parameters monitored by both the sequence-of-events and time. history recorders.

9 9

1

.m i :

c

===1.

Background===

On February 25, 1984, both of the scram circuit breakers at Unit 1 of

~

the Salam Nuclear Power Plant failed to open upon an automatic reacto'r trip signal from the reactor protection system.

This incident occurred during the plant startup and the reactor was tripped manually by the operator about 30 seconds after the initiation of the automatic trip signal. The failure of the circuit breakers has been determined to be related to the, sticking of the under voltage trip attachment. Prior to this. incident; on February 22, 1983; at Unit 1 of the Salen Nuclear Power Plant an automatic trip signal was generated based on steam generator low-low level during plant startup.

In this case the reactor was tripped manually by the operator almost coinci-dentally with the automatic trip. At that time, because the utility did not have a requirement for the systematic evaluation of the reactor trip, no investigation was performed to determine whether the reactor was tripped automatically as expected or manually. The utilities' written procedures required only that the cause of the trip be determined and identified the responsible personnel that could authorize'a restart if the cause of the trip is known.

Following the second trip which clearly indicated the problem with the trip breakers, the question was raised on whether the circuit breakers had functioned properly during the earlier incident.

The most useful source of information in this case, namely the sequence of svents printout which would have indicated whether the reactor was tripped automatically er manually during the February 22 incident, was not retained after the incident. Thus, no A,dgment on the proper functioning of the trip system during the earlier incident cc,uld be made.

Following these incidents; on February 28,1983; the NRC Executive Director for Operations (EDO), directed the staff to investigate and report on the generic implications of these occurrences at Unit 1 of the Salem Nuclear Power Plant.' The results of the staff's inquiry into the generic implications.of the Salem Unit incidents is reported in NUREG-1000. " Generic Implications of ATWS Events at the S&lem Nuclear Power Plant." Based on the results of this study, a set of required actions were developed and included in Generic l.etter 83-28 which was issued on July 8,1983 and sent to all licensees of operating reactors, applicants for operating license, and construction permit holders. The required actions in this generic letter consist of four categories. These are:

(1) Post-Trip Review, (2) Equipment 2

i

-s

,--.-,,n-a w - e

--mm-mv+=~~r'~

" '" ""*'~'""

t

~.

Classification and Vender Interface. '(3) Post Maintenance Testing, and (4)

Reactor Trip System Reliability Improvements.

The first required action of the generic letter. Post-Trip Review, is the subject of this TER and consists of action item 1.1 " Program Description and Procedure" and action item 1.2 " Data and Information Capability." In the next section the review criteria used to assess the adequacy of the utilities' responses to the requirements of action item 1.2 will be discussed.

2.

Review Criteria The intent of the Post Trip Review requirements of Generic Letter 83-28 is to ensure that the licensee has adequate procedures and data and information sources to understand the causehnd progression of a reactor trip. This understanding should go beyond a simple identification of the course of the event. It should include the capability to determine the root cause of the reactor trip and to determine whether safety limits have been exceeded and if so to what extent. Sufficient information about the reactor trip event should be available so that a decision on the acceptability of a reactor restart can be made.

The following are the review criteria developed for the requirements of l

Generic Letter 83-28. action item 1.2:

The equipment that provides the digital sequence of events (SOE) record and the analog time history records of an unscheduled shutdown should pro-vide a reliable source of the necessary information to be used in the post trip review.

Each plant variable which is necessary to determine the cause(s) and progression of the event (s) following a plant trip should be monitored by at least one recorder Quch as a sequence-of-events recorder or a plant process computer for digital parameters; and strip charts, a plant process computer or analog recorder for analog (time history) variableQ.

Ea.ch device used to record an analog or digital plant variable should be described in sufficient detail so that a determination can be made as to whether the following performance characteristics are met:

3 w

-.mmen.sy+,,

.~

w

' +

~ w ~

__._________.____=_J H

1 Each sequer.ce-of-events recorder should be capable of detecting j

e

- e i

and recording the sequence of events with a sufficient time discrimination capability to ensure that the time responses..asso-i l

ciated with each monitored safety-related system can be ascer-tained, and that a determination can be made as to whether the time response is within acceptable limits based on FSAR Chapter 15 Accident Analyses.

The recommended guideline for the SOE time discrimination is approxi-i mately 100 esec.

If current SOE recorders do not have this time discrimination capability the licensee or applicant should show that the current time discrimination capability is sufficient for an adequate reconstruction of the course of the reactor trip.

As a minimum this should include the ability to adequately recon-l struct the accident scenarios presented in Chapter 15 of the plant FSAR.

Each analog time history data recorder should have a sample inter-o val small enough so that the incident can be accurately reconstr'ucted following a reactor trip.

As a minimum, the i

licensee or applicant should be able to reconstruct the course of the accident sequences evaluated in the accident analysis of the plant FSAR (Chapter 15). The recommended guideline for the sample interval is 10 sec.

If the time history equipment does not meet this guideline, the licensee or applicant should show that the current time history c,apability is suffletent to accurately recon-struct the accident sequences presented in Chapter 15 of the FSAR.

To support the post trip analysis of the cause of the trip and the e

l proper functioning of involved safety related equipment, each analog time history data recorder should be capable of updating and retaining information from approximately five minutes prior to the trip until at least ten minutes after the trip.

e The information gathered by the sequence-of-events and time history data collectors should be stored in a manner that will allow for retrieval and analysis. The data may be retained q

in either hardcopy (computer printout, strip chart output, etc.)

or in an accessible memory (magnetic disc or tape).

This 4

4 i

.my--,-g-he

  • -m*'"

-rN**7'F

'-**WBMe=

+ - -

,w-e-

- ---mewm.

e information should be presented in a readable and meaningful format, taking into consideration good human factors practices (such as those outlined in NUREG-0700).

~~

~

i e

All equipment used to record sequence of events and time history information should be powered from a reliable and non-interruptible power source. The power source used need not be safety related.

4, j

The sequence of events and time history recording equipment should monitor sufficient digital and analog parameters, respectively, to assure that the course of the reactor trip can be reconstructed. The parameters monitored should provide sufficient information to determine the root cause of the reactor trip, the progression of the reactor trip, and the response of the plant parameters and systems to the reactor trip.

Specifically, all input parameters associated with reactor trips, safety injections and other safety-related systems as well as output parameters sufficient to record the proper functioning of these systems should be recorded for use in the post i

trip review. The parameters deemed necessary, as a minimum, to perform a post-trip review (one that would determine if the plant remained within its design envelope) are presented on Tables 1.2-1 and 1.2-2.

If the appli-cants' or licensees' SOE recorders and time history recorders do not monitor i

all of the parameters suggested in these tables the applicant or licensee l

should show that the existing set of monitored parameters are sufficient to l

establish that the plant remain *d within the design envelope for the appro-j priate accident conditions; such as those analyzed in Chapter 15 of the j

plant Safety Analysis Report.

Information gathered during the post trip review is required input for j

future post trip reviews.

Data from all unscheduled shutdowns provides a valuable reference source for the determination of the acceptability of the l

plant vital parameter and equipment response to future unscheduled shut-i downs.

It is therefore necessary that information gathered during all post trip reviews be maintained in an accessible manner for the life of the i

plant.

l 5

j um

t 1

Table 1.2-1.

PWR Parameter List

~

SOE Time History Recorder Recorder Parameter / Signal (l) x Reactor Trip (1) x Safety Injection x

Containment Isolation (1) x Turbine Trip x

Control Rod Position (1) x.

x Neutron Flux, Power x

A Containment Pressure (2)

Containment Radiation x

Containment Sump Level (1) x x

Primary System Pressure (1) x x

Primary System Temperature (1) x Pressurizer Level (1) x Reactor Coolant Pump Status (1) x x

Primary System Flow (3)

Safety Inj.; Flow. Pump / Valve Status x

MSIV Position x

x Steam Generator Pressure (1) x x

Steam Generator Luel (1) x x

Feedwater Flow (1) x x

Steam Flow (3)

Auxiliary Feedwater System; Flow.

Pump /Value Status AC and DC System Status (Bus Voltage) x Diesel Generator Status (Start /Stop, x

On/Off) x PORY Position (1.): Trip parameters (2): Parameter may be monitored by either an SOE or time history recorder.

(3): Acceptable recorder options are: (a) system flow recorded on an SOE recorder (b) system flow recorded on a time history recorder, or (c) equipment status recorded on an SOE recorder.

6 l

(

Table 1.2-2.

BWR Parameter List

~~

SOE Time History Recorder Recorder Parameter / Signal x

Reactor Trip x

Safety Injection x

Containment Isolation x

Turbine Trip x

Control Rod Position x (1) x Neutron Flux, Power x (1)

Main Steam Radiation (2)

Containment (Dry Well) Radiation

}

x (1) x Drywell Pressure (Containment Pressure)

(2)

Suppression Pool Temperature x (1) x Primary System Pressure x(1) x Primary System Level j

x MSIV Position i

x (1)

Turbine Stop Valve / Control Valve Position x

Turbine Bypass Valve Position j

x Feedwater Flow l

x Steam Flow (3)

Recirculation; Flow Pump Status

)

x (1)

Scram Discharge Level x (1)

Condenser Vacuum l

AC and DC System Status (Bus Voltage) x l

(3)(4)

Safety Injection; Flow. Pump / Valve Status x

Diesel Generatcr Status (On/Off, Start /Stop) i (1):Tripparameters.

(2): Parameter may be recorded by either an SOE or time history recorder.

(3.): Acceptable recorder options are: (a) system flow recorded on an SOE recorder (b) system flow recorded on a time history recorder, or (c) equipment status recorded on an SOE recorder.

(4): Includes recording of parameters for all appitcable systems from the following: HPCI, LPCI, LPCS, IC, RCIC.

7 n ~ ~ ns

~--om~~

  • ~'

- - = -

3.

Evaluation

~

The parameters identified in part 2 of this report as a part Of the review criteria are those deemed necessary to perform an adequate post-trip l

review. The recording of these parameters on equipment that meets the l

guidelines of the review criteria will result in a source of information that can be used to determine the cause of the reactor trip and the plant response to the trip, including the responses of important plant systems.

The parameters identified 1.n this submittal as being recorded by the sequence of events and time history recorders do not correspond to the parameters specified in part 2 of this report.

The information provided in the submittal indicates that the equipment used to monitor the digital and analog parameters meets the minimal requirements set forth in part 2 of this report. The sequence of events and analog time history recorders are powered from a non-interruptable power supply. The monitoring characteristics are all within the guidelines of the review criteria.

The data and information recorded for use in the post-trip review should be output in a format that allows for ease of identification and use of the data to meet the review criterion that calls for information in a readable and meaningful format. The information contained in this submittal indicates that this requirement is met.

~

The data and information used during a post-trip review should be retained as part of the plant files. This information could prove useful during future post-trip revfews. Therefore one requirement presented in part 2 of this report is that information used during a post-trip review be maintained in an accessible manner for the life of the plant.

Information contained within this submittal indicates that this criterion will be met.

4.

Conclusion The information supplied in response to Generic Letter 83-28 indicates that the current post-trip review data and information capabilities are adequate in the following areas:

8 i

1.

The SOE recorders meet the minimum performance characteristics.

2.

The time history recorders meet the minimum performance character-istics.

3 ',

The recorded data is output in a readable and meaningful format.

4.

The information recorded for the post-trip review is maintained in an accessible manner for the life of-the plant.

The information supplied.in response to Generic Letter 83-28 does not indicate that the post-trip review data and information capabilities are adequate in the following area:

1.

As described in the submittal, sufficient analog and digital parameters are not recorded for use in the post-trip review.

It is possible that the current data and information capabilities at this l

nuclear power plant are adequate to meet the intent of these requirements, j

but were not completely described. Under these circumstances, the licensee should provide an updated, more complete, description to show in more detail the data and information capabilities at this nuclear power plant.

If the information provided accurately represents all current data and information capabilties, then the licensee should either show that the parameters currently recorded will enable,the licensee to determine that the reactor trip progressed within the design limits of the Safety Analysis Report accident analysis, or detail future modifications that would enable the licensee to meet the intent of the evaluation criteria.

9 l

l

n REFERENCES MRC Generic Letter 83-28.

" Letter to all licer. sees of operating reactors, applicants for operating license, and holders of construction permits regarding Required Actions Based on Generic Implications of Salem ATWS Events." July 8, 1983.

NUREG-1000 Generic Implications of ATWS Events at the Sales Nuclear Power Plant, April 1983.

Letter from J.0. Schuyler, Pacific Gas and Electric Company, to 0.G.

Eisenhut, NRC, dated November 7,1983, Accession Number 8311110160 in response to Generic Letter 83-28 of July 8,1983, with attachment.

Response to Generic Letter 83-28, Status of Current Conformance, Plans, and Schedules.

Letter from J.O. Schuyler, Pacific Gas and Electric Company to 0.G.

Eisenhut, NRC, dated June 27,1984, DCL-84-242, in response to Item 1.2 of Generic Letter 83-28 of July 8,1983, with attachment.

Response to Action Item.1.2 of Generic Letter 83-28. " Post-Trip Review-

- Data and Information Capability.

10 tr---

we----r---,-wi

--ww--rr----,,--w---

---y w-e--w-------m e-----y

-,e-

---=+w--w+-m----mw---+-w----

w

-+

m

== - - - - >----e+

Suf/*4 % pm m y 9 mecw Diablo Canyon 3

4 1.

Parameters recorded: Unsatisfactory See attached table for discrepancies.

2.

SOE recorders performance characteristics: Satisfactory Plant process computer:

16.6 msec time discrimination with a non-interruptible power supply l

ERFDS:

16.6 msec time discrimination with a non-interruptible power supply i

3.

Time history recorders performance characteristics: Satisfactory

~

Plant process computer:

parameters are sampled at 2 and 8 sec intervals for the period from 2 min before to 3 min after the trip ERFDS: parameters are sampled at 1 sec intervals for the period from 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> before to 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> after the trip (This device samples the required analog parameters.)

4.

Data output format: Satisfactory SOE data output includes time, event descriptor, and sensor 10.

Analog data output includes time, parameter name and value, and sensor ID.

5.

Data retention capability: Satisfactory Post-trip review dt.ta is' maintained for the life of the plant.

i i

l h\\

l

r e

Required PWR Parameters for Post Trip Review (circled parameters are not recorded)

~~

SOE Time History Recorder Recorder Parameter / Signal

" Q) x Reactor Trip (1)

Safety Injection Containment Isolation (1)

Turbine Trip Control Rod Position (1) x x

Neutron Flux, Power x

X Containment Pressure (2)

Containment Radiation x

Containment Sump Level (1)(3)

Primary System Pressure (Vessel Pressure, Pressurizer Pressure)

(1) x x

Primary System Temperature (1) x Pressurizer Level (1) x Reactor Coolant Pump Status (1) x x

Primary System Flow (4)

Safety Inj.; Flow Pump / Valve Status x

MSIV Position x

x Steam Generator Pressure (1) x x

Steam Generator Level (1) x x

Feedwater Flow (1) x x

Steam Flow (4)

Auxiliary Feedwater System; Flow.

Pump /Value Status x

AC and DC System Status Diesel Generator Status-x PORY Position (1): Trip parameters; pressurizer or primary pressure is a trip parameter (depending on plant).

(2): Parameter may be monitored by either an SOE or time history recorder.

(3): Acceptable recorder options are:

(a) reactor vessel pressure recorded on both an SOE and time history recorder, or (b) pressurizer pressure recorded on both an SOE and time history recorder.

(4): Acceptable recorder options are: (a) system flow recorded on an SOE recorder, (b) system flow recorded on a time history recorder, or (c) equipment status recorded on an SOE recorder.

\\O

-.