Rev 0 to Procedure CP-CPM-18.1, Const-Maintained QA Records
ML20198K450
Person / Time
Site: Comanche Peak  
Issue date: 04/27/1981
From:
BROWN & ROOT, INC. (SUBS. OF HALLIBURTON CO.)
To:
Shared Package
ML20197J316 List: ... further results
References
FOIA-85-59 CP-CPM-18.1, NUDOCS 8606040032
Download: ML20198K450 (3)


Text

.

a r-.

'1l 6 I!!DEXto SROWN & ROOT, INC.

PROCECURE

WVE i CPSES NUMBER RE7ISION Dec, DATE ME JOB 35-1195 C P-C PM-18.1 0

4/27/81 1 of 3 TITLE:

ORIGINATOR:

~%~

M Y-29-81 CAIE j[ [ b CONSTRUCTION-REVIEWED BY:/

na4/

L T

d-g #/

R p

QA/GL CAi-APPROVED SY: WJ

& Newd:4? M'WF/

u C0t4STRUCTI0t4 PROJECT MApA)ER GATE o.1 TABLE OF CONTENTS

1.0 REFERENCES

2.0 INTRODUCTION

J.1 2.1 PURPOSE 2.2 SCCPE y

=3' 3.0 PROCEDURE 3.1 DOCUMENT CHECKLIST 3.1.1 Occument Control 3.1.2 Furenasing 3.1.3 Calibration 3.1.4 Weiding

1.0 REFERENCES

1.1 ANSI fl45.2.9, "Recuirements for Collection, Storage and Main-tenance of Quality Assurance Records for Nuclear Power Plant".

1.2 ASME Section III, paragraph 4930, " Retention of Records".

2.0 INTRODUCTION

2.1 PURPOSE The purpose of this procedure is to identify QA Records wnich dre maintained by construction.

F 2.2 SCOPE This procedure a::alies to those records that are generated fcr construction and are specified as being Quality Assurance re-cords.

Excluded from the scope of this procedure are Pose records that are of a verification nature and are currently stored by the QA Department.

l 8606040032 060527 PDR FOIA GARDE 85-59 PDR e-g d'- /22

7:

PROCEDURE i EFFECTIVE i

BROWN & RCOT, INC.

NL'MSER I REVISION l DATE l

PAGE es CPSES I

JOB 35-1195 i

CP-CPM-18.1 j 0

l 4/27/81 l

2 of 3 NOTE: For records generated prior to commercial operation, the retention pericd begins on the date of commercial ocera-tion.

record retention periods have been cmitted.

r records cited herein shall be maintained through-out construction. Prior to commencement of commercial operation, these records shall be submitted to the Per-manent Plant Records Vault Supervisor who shall be re-sponsible for the assignment of retention periods in accordance with references 1.1 and 1.2.

' 3.0 PROCEDURE 3.1 DOCUMENT CHECKLIST The following is a checklist of records, segregated by responsi-ble department, that shall be maintained by Construction.

3.1.1 Document Control 1.

All construction procedures.

2.

Welding Procedures.

3.

Storage and maintenance requirements.

4.

Design and construction drawings including:

a.

BRH's b.

Hanger Location Drawings c.

BRP's d.

Field Sketches 1.

Civil 2.

El ectrical 3.

Instrumentation 4.

Mechanical e.

Vendor Drawings f.

Gibbs & Hill, Inc. Design Drawings 1.

Architectural 2.

El ectrical 3.

Mechanfcal g.

Miscellanecus Steel Drawings x.

h.

Rebar Drawings

i. Concrete Isemetric Drawings e

~ '.V PROCEDUR:-

F:ECTIVE BROWN & RCOT, INC.

NUMBER REVISION DATE PAGE b

CPSES l

l JOB 35-1195 a

CP-CPM-18.1 l

0 l 4/27/81 l

3 of 3

j. Lighting Drawings 5.

Design Records a.

Design Change Requests 1.

DCRP - Design Change Request to Procedure 2.

FPAR

, Field Problem Action Request 3.

FICR - Field Interpretation Clarification Request 4.

FDCR - Field Design Change Request b.

Design Changes / Deviations 1.

CMC - Component Modification Card 2.

DCA - Design Change Authorization 3.

DECD - Design Engineering Change Documentation 4.

DCDD - Design Change Deviation Document 5.

DCDDA - Design Change Design Deviation Authorization 6.

Vendor Manuals - Includes design, installation, maintenance and/or operation manuals.

7.

Design Specifications, including revisions and addendums.

3.1.2 Purchasing 1.

Procurement Specifications 2.

Purchase Orders, including amendments 3.

Pre-Bid Eviluation Form 4.

Final Biddei s List 3.1.3 1.

IEI Series - Manual of Instrument Engineering Instructions For Calibration Of Measuring And Test Equipment.

2.

Personn ification and Training Record a.

Brown & Root Calibration Report b.

Deficient M&TE Evaluation Report c.

Calibration Master Irtdex h]senhwessuruu4rs3lip h

dhlvb

-[ad 3.1.4 Welding 1.

Welder Qualification Matrix e

_