MONTHYEARML20210C3781999-07-20020 July 1999 Notice of Violation from Insp on 990318.Violations Noted: on 980224,individual Attempted to Enter Protected Area of Plant with Firearm.Search Equipment Operator Failed to Failed to Secure Item & Prevent Access ML20210C4301999-07-20020 July 1999 Notice of Violation from Investigation on 990318.Violation Noted:On 980224,recipient Caused Util to Be in Violation of Section 2.C.6 of Licenses DPR-39 & DPR-48.Recipient Attempted to Enter Protected Area of Station with Handgun ML20205P2211999-04-0909 April 1999 Notice of Violation from Insp & Investigation Completed on 981112.Violation Noted:From Approx July,1997 to 980122,SGI Was Not Stored in Locked Storage Container While Unattended ML20203H8601998-02-25025 February 1998 Notice of Violation from Insp on 971217-980202.Violation Noted:Licensee Returned to Svc Valves 2FW0038 & 2FW0042 in Locked Position Instead of Locked Closed Position ML20202D7291998-02-0606 February 1998 Notice of Violation from Insp on 970120-23.Violation Noted: on 980115,radiation Protection Technician Performed Calibration of Auxiliary Bldg Exit Personnel Contamination Monitor & Failed to Reset Monitor to Initial Setting ML20199G3271998-01-27027 January 1998 Notice of Violation from Insp on 970908-1216.Violation Noted:As of 970724,licensee Failed to Ensure That Training Provided to Selected Contractor Craft & Quality Control Insp Personnel Performing Raychem Splice Applications IR 07100011/20120161998-01-21021 January 1998 Notice of Violation from Insp on 971011-1216.Violations Noted:Procedures Were Not Appropriate to Circumstances in Listed Instances ML20198P5561998-01-15015 January 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000.Violations Noted:Three FFD Trained Supervisors Failed to Require for-cause Test for Employee W/Smell of Alcohol in Protected Area ML20203E5111997-12-0505 December 1997 Notice of Violation from Insp on 971027-31.Violation Noted:On 971017-18,entrance to Truck Bay of Radioactive High Level Waste Area Was Not Locked & Personnel Did Not Have Direct Oversight ML20202D9291997-11-28028 November 1997 Notice of Violation from Insp on 970830-1010.Violation Noted:On 970910,while Returning QA Fire Pump Breaker to Svc IAW out-of-svc Number 970009297,non-licensed Operator Did Not Close Control Power Knife Switch as Required ML20211J7991997-10-0202 October 1997 Notice of Violation from Insp on 970409-0730.Violation Noted:Zion Station Measures to Control Matls Were Inadequate & Did Not Prevent Installation of Following,From 1992 to 1997,high Efficiency Particulate Air Filters ML20217F0861997-09-30030 September 1997 Notice of Violation from Insp on 970719-0829.Violation Noted:On 970827,engineering Contractor Operated 2C Svc Water Pump Lower Bearing Suppl Isolation valve,2SW0624,w/o Authorization from Operations Dept ML20217A3371997-09-12012 September 1997 Notice of Violation from Insp on 961207-970527.Violation Noted:During 1996 Unit 2 Refueling Outage,Irradiated Fuel Was Moved & Fuel Was Stored in Pool W/Less than 60 Days Decay Time & Fuel Bldg Exhaust Sys Was Operating ML20217R2441997-09-0202 September 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $330,000.Violation Noted:Primary Nso Did Not Establish Power at or Less than Point of Adding Heat IAW GOP-4,step 5.21.f ML20216C4801997-08-28028 August 1997 Notice of Violation from Insp on 970530-0718.Violation Noted:On 970510,during Performance of OSP 97-012,section 5.58,licensee Failed to Close 3L Kiene Valve ML20217R3411997-08-26026 August 1997 Notice of Violation from Insp on 970728-0801.Violation Noted:High Radiation Area W/Radiation Levels Greater than 1000 Mrem/Hr Was Not Locked & Personnel Did Not Have Direct Oversight of & Positive Control Over Each Entry Into Area ML20217P9661997-08-15015 August 1997 Notice of Violation from Insp on 970404-0529.Violations Noted:Fire Resulted When Mechanical Maint Personnel Did Not Ensure That Adequate Natural or Mechanical Ventilation Was Established While Applying Flammable Lubricant to Rv Holes ML20149G6341997-07-17017 July 1997 Notice of Violation from Insp on 970311-0425.Violation Noted:On 970311,licensee Identified That Procedure Did Not Exist for Responding to Loss of Offsite Power That Resulted When Unit 1 Sys Auxiliary Transformer Tripped ML20148L6491997-06-17017 June 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Violation Noted:Two Licensee Personnel Were Not Trained in DOT & NRC Regulatory Requirements,Waste Burial & Instructions for Transfer & Transport of Radwaste ML20140G8161997-06-0404 June 1997 Notice of Violation from Insp on 970206-0402.Violation Noted:Periodic Test PT-6C-ST-RT, Containment Spray C Pump Sys Tests & Checks, Rev 8 Was Inadequate to Demonstrate That Containment Spray Sys Will Perform Satisfactorily ML20148B7751997-05-0606 May 1997 Notice of Violation from Insp on 970324-0414.Violation Noted:Cords & Hoses Crossing Contamination Boundaries Were Not Properly Secured on Auxiliary Bldg 617 Elevation at Exit from Fuel Bldg ML20140G0371997-04-30030 April 1997 Notice of Violation from Insp on 970317-21.Violation Noted: Review of EP Program in Site Quality Verification Audit Qaa 22-95-04, Generating Station Emergency Plan Did Not Address Adequacy of Offsite Interface W/State of Il ML20137J6801997-03-24024 March 1997 Notice of Violation from Insp on 961207-970205.Violation Noted:Control Room Operators Failed to Select Operable Instrument Channel ML20136G6251997-03-12012 March 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $100,000.Violation Noted:On 960318 Licensee Did Not Perform Adequate Safety Evaluation to Determine If Temporary Alteration 96-014 Constituted Safety Questions ML20134H0851997-02-0303 February 1997 Notice of Violation from Insp on 961012-1206.Violation Noted:On 961102,RHRS Heat Exchanger a Discharge to Letdown Heat Exchanger Valve 2RH-8734A Was Operated ML20134G0421997-01-28028 January 1997 Notice of Violation from Insp on 960824-1011.Violation Noted:On 960915,during 2B Safety Injection Pump Component Cooling Water Flow Transmitter Work Activities,Licensee Personnel Failed to Perform Actions Required by Zap 1200-08 ML20133A3291996-12-23023 December 1996 Notice of Violation from Insp on 961001-03,28-30 & 1107. Violations Noted:Licensee Failed to Take Prompt Action Prior to Returning Potentially Defective Steam Generator Tubes to Svc ML20134P1641996-11-21021 November 1996 Notice of Violation from Insp on 960923-1024.Violations Noted:Unqualified Personnel Not Following Procedure Re Radiation Detection Device,Radiation Monitors Inoperable & Grab Bags Not Taken & Analyzed Per Shift ML20129F0321996-10-22022 October 1996 Notice of Violation from Insp on 960713-0829.Violation noted:FHI-02,Step 9 Inappropriate to Circumstances & Did Not Specify How to Properly Reg Shipping Container for Lift ML20129F0551996-09-16016 September 1996 Notice of Violation from Insp on 960608-0726.Violation Noted:Licensee Designated Individuals to Be Responsible for Directing Licensed Activities of Licensed Operators,Who Were Not Licensed as Senior Operators ML20059H1221994-01-19019 January 1994 Notice of Violation from Insp on 931124-940106.Violations Noted:Procedure Chosen to Monitor Degraded IC Contaminate Spray Pump Starting Times Did Not Contain Requirements or Acceptance Criteria to Evaluate Acceptability of Delays ML20058H2421993-12-0707 December 1993 Notice of Violation from Insp on 931012-1123.Violation Noted:Removal of Fuel from Unit 1 Reactor Vessel Was Not Suspended When All Unit 1 EDG Were Rendered Inoperable Due to Isolation of Svc Water to Generators ML20059A0001993-10-15015 October 1993 Notice of Violation from Insp on 920818-1005.Violation Noted:Licensee Records or License Conditions Not Complete & Accurate in All Matls Respects ML20057A6501993-09-0909 September 1993 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Action Based on Listed Violations Including Open Door to Laundry Facility Creating Potential Unmonitored Release Path ML20128A2031993-01-26026 January 1993 Notice of Violation from Insp on 921214-930104.Violation Noted:Licensee Failed to Evaluate Results of 17 Dp Tests Completed During Spring 1992 Outage to Demonstrate That MOVs Would Perform Safety Function ML20127J0821993-01-19019 January 1993 Notice of Violation from Insp on 921027-930108.Violation Noted:On 921002,licensee Failed to Perform Independent Verification of Position of Unit 1,1B Motor Driven Afp Discharge IV Following Valve Realignment & Return Svc ML20126J2311992-12-29029 December 1992 Notice of Violation from Insp on 921207-11.Violation Noted: on 921209 Operator Failed to Review,Sign & Comply W/ Appropriate Radiation Work Permit Prior to Entering High Radiation Areas in Which Radiography About to Commence ML20125C6761992-12-0404 December 1992 Notice of Violation from Insp on 921005-29.Violations Noted: 10CFR50.59 Safety Evaluation for Temporary Alteration 90-053 Not Adequate to Provide Basis for Determination That Temporary Alteration Did Not Involve Unreviewed Question ML20062F1081990-11-0808 November 1990 Notice of Violation from Insp on 900910,24-28 & 1018. Violation Noted:Records Documenting Completion of Required Inventories Not Available for Seven Quarterly Inventories ML20058F4711990-10-31031 October 1990 Notice of Violation from Insp on 900924-1012.Violation Noted:Failure to Submit LER within 30 Days After Discovery of Reactor Head Venting Via Purge Exhaust Sys W/O Min Number of Required Channels Operable ML20059N1111990-09-21021 September 1990 Notice of Violation from Insp on 870415 & 24 & Subsequent Insp on 900424-0508 & 29.Violation Noted:Nonlicensed Shift Foreman Failed to Verify Valve Lineup for Discharge,Which Led to Radiation Control Procedures Not Being Implemented ML20059H1601990-09-0606 September 1990 Notice of Violation from Insp on 900716-0808.Violation noted:11 Incidents in Which Access to High Radiation Areas Not Controlled as Required by Procedure Zap 5-51-15 ML20059A2651990-08-14014 August 1990 Notice of Violation from Insp on 891127-1208.Violations Noted:Established Measures Failed to Assure That Cause of Significant Condition Adverse to Quality & Fretting of Emergency Diesel Generator Small Diameter Tubing Identified ML20247L1031989-09-14014 September 1989 Notice of Violation from Insp on 890717-21 & 0811.Violation Noted:Fire Marshall Not Contacted to Determine If Increased Surveillance of Elevation 579 of Auxiliary Bldg Required Due to Presence of Transient Combustible Near Redundant Sys ML20247A8221989-09-0101 September 1989 Notice of Violation from Insp on 890619-23 & 0717-21 & 24. Violations Noted:Electrolyte Levels for Battery 212 Verified Between Full & Low Level Line & Wrong Procedure Used to Repair Limitorque Operator for Valve 2MS006 ML20247J0991989-07-24024 July 1989 Notice of Violation from Insp on 890509-0629.Violation Noted:Facility Did Not Have Appropriate Prescriptive Instructions or Procedures for Sampling of safety-related Fuel Oil for Emergency Diesel Generator Storage Tanks ML20245F0351989-06-19019 June 1989 Notice of Violation from Insp on 890531.Violation Noted:Unit 1 Operated at Power Levels Up to 100% from 890311-18,period in Excess of 48 H ML20244C6281989-04-10010 April 1989 Notice of Violation from Insp on 890210-0317.Violation Noted:On 890225,both QC & QA Signed Off Hold Point as Acceptable W/O Noting That Weld 4 Data Had Been Recorded as Weld 3 ML20248C3771989-03-27027 March 1989 Notice of Violation from Insp on 881215-890104.Violation Noted:Isotopes Shipped in Overpack That Failed to Meet Marking & Labeling Requirements ML20246L3881989-03-10010 March 1989 Notice of Violation from Insp on 890104-0210.Violation Noted:Test Procedure PT-7B, Auxiliary Feedwater Pump Svc Water Valves Operability Checks, on Units 1 & 2 Failed as- Found Stroke Time 1999-07-20
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000295/19990031999-09-0101 September 1999 Insp Repts 50-295/99-03 & 50-304/99-03 on 990608-0812.No Violations Noted.Major Areas Inspected:Licensee Facility & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety ML20210C3781999-07-20020 July 1999 Notice of Violation from Insp on 990318.Violations Noted: on 980224,individual Attempted to Enter Protected Area of Plant with Firearm.Search Equipment Operator Failed to Failed to Secure Item & Prevent Access ML20210C4301999-07-20020 July 1999 Notice of Violation from Investigation on 990318.Violation Noted:On 980224,recipient Caused Util to Be in Violation of Section 2.C.6 of Licenses DPR-39 & DPR-48.Recipient Attempted to Enter Protected Area of Station with Handgun IR 05000295/19990021999-06-18018 June 1999 Insp Repts 50-295/99-02 & 50-304/99-02 on 990121-0608.No Violations Noted.Major Areas Inspected:Licensee Facility Management & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety ML20205P2211999-04-0909 April 1999 Notice of Violation from Insp & Investigation Completed on 981112.Violation Noted:From Approx July,1997 to 980122,SGI Was Not Stored in Locked Storage Container While Unattended IR 05000295/19980101998-11-0303 November 1998 Insp Repts 50-295/98-10 & 50-304/98-10 on 980814-1008.No Violations Noted.Major Areas Inspected:Facility Mgt & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000295/19980091998-09-0808 September 1998 Insp Repts 50-295/98-09 & 50-304/98-09 on 980626-0813.No Violations Noted.Major Areas Inspected:Facility Mgt & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000295/19980071998-06-26026 June 1998 Insp Repts 50-295/98-07 & 50-304/98-07 on 980425-0609.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support PNO-III-98-030, on 980517,armed Security Guard on Patrol in Owner Controlled Area Reported to Security Person Lying Near Road.Guard Subsequently Reported Being Shot.No Intruder Found.Guard Admitted Shooting Himself in Foot1998-05-18018 May 1998 PNO-III-98-030:on 980517,armed Security Guard on Patrol in Owner Controlled Area Reported to Security Person Lying Near Road.Guard Subsequently Reported Being Shot.No Intruder Found.Guard Admitted Shooting Himself in Foot IR 05000295/19980061998-04-23023 April 1998 Insp Repts 50-295/98-06 & 50-304/98-06 on 980330-0403.No Violations Noted.Major Areas Inspected:Plant Support IR 05000295/19980041998-03-31031 March 1998 Insp Repts 50-295/98-04 & 50-304/98-04 on 980203-0313.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000295/19980021998-03-0606 March 1998 Insp Repts 50-295/98-02 & 50-304/98-02 on 980112-0219.No Violations Noted.Major Areas Inspected:Plant Support ML20203H8841998-02-25025 February 1998 Insp Repts 50-295/97-32 & 50-304/97-32 on 971217-980202. Violations Noted.Major Areas Inspected:Operations, Engineering & Plant Support ML20203H8601998-02-25025 February 1998 Notice of Violation from Insp on 971217-980202.Violation Noted:Licensee Returned to Svc Valves 2FW0038 & 2FW0042 in Locked Position Instead of Locked Closed Position ML20202D7291998-02-0606 February 1998 Notice of Violation from Insp on 970120-23.Violation Noted: on 980115,radiation Protection Technician Performed Calibration of Auxiliary Bldg Exit Personnel Contamination Monitor & Failed to Reset Monitor to Initial Setting ML20202D7441998-02-0606 February 1998 Insp Repts 50-295/98-03 & 50-304/98-03 on 980120-23. Violations Noted.Major Areas Inspected:Plant Support Performance & Specifically,Evaluation of Effectiveness of Radiation Protection Program IR 05000295/19970271998-01-30030 January 1998 Insp Repts 50-295/97-27 & 50-304/97-27 on 971117-25.No Violations Noted.Major Areas Inspected:Licensed Reactor Operator & Senior Reactor Operator Requalification Training Programs ML20199G3461998-01-27027 January 1998 Insp Repts 50-295/97-23 & 50-304/97-23 on 970908-1216. Violations Noted.Major Areas Inspected:Engineering ML20199G3271998-01-27027 January 1998 Notice of Violation from Insp on 970908-1216.Violation Noted:As of 970724,licensee Failed to Ensure That Training Provided to Selected Contractor Craft & Quality Control Insp Personnel Performing Raychem Splice Applications ML20199A2461998-01-21021 January 1998 Insp Repts 50-295/97-25 & 50-304/97-25 on 971011-1216. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 07100011/20120161998-01-21021 January 1998 Notice of Violation from Insp on 971011-1216.Violations Noted:Procedures Were Not Appropriate to Circumstances in Listed Instances PNO-III-98-006, on 980115,licensee Announced Permanent Shut Down of Station.Util Plans to Maintain Plant in Safstor Decommissioning Mode Until Approx 20141998-01-15015 January 1998 PNO-III-98-006:on 980115,licensee Announced Permanent Shut Down of Station.Util Plans to Maintain Plant in Safstor Decommissioning Mode Until Approx 2014 ML20198P5561998-01-15015 January 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000.Violations Noted:Three FFD Trained Supervisors Failed to Require for-cause Test for Employee W/Smell of Alcohol in Protected Area ML20216D7411998-01-12012 January 1998 EN-98-002:on 980115,notice of Proposed Imposition of Civil Penalty in Amount of $110,000 Issued to Licensee.Action Based on Severity Level III Problem Involving Implementation of fitness-for-duty Program at Zion Station IR 05000295/19970291998-01-0909 January 1998 Insp Repts 50-295/97-29 & 50-304/97-29 on 971202-05.No Violations Noted.Major Areas Inspected:Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000295/19970211997-12-0909 December 1997 Insp Repts 50-295/97-21 & 50-304/97-21 on 970602-0919.No Violations Noted.Major Areas Inspected:Licensee Developed Phoenix Training Program as Part of Station Restart Action Plan ML20203E5111997-12-0505 December 1997 Notice of Violation from Insp on 971027-31.Violation Noted:On 971017-18,entrance to Truck Bay of Radioactive High Level Waste Area Was Not Locked & Personnel Did Not Have Direct Oversight IR 05000295/19970261997-12-0505 December 1997 Insp Repts 50-295/97-26 & 50-304/97-26 on 971027-31. Violations Noted.Major Areas Inspected:Plant Support, Performance & Evaluated Effectiveness of Radiation Protection Program IR 05000295/19970311997-12-0404 December 1997 Predecisional Enforcement Conference Repts 50-295/97-31 & 50-304/97-31 on 971201.Violations Noted.Major Areas Discussed:Violations Involving Failures to Adequately Implement fitness-for-duty Program Requirements ML20202D9291997-11-28028 November 1997 Notice of Violation from Insp on 970830-1010.Violation Noted:On 970910,while Returning QA Fire Pump Breaker to Svc IAW out-of-svc Number 970009297,non-licensed Operator Did Not Close Control Power Knife Switch as Required ML20202D9401997-11-28028 November 1997 Insp Repts 50-295/97-22 & 50-304/97-22 on 970830-1010. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000295/19970171997-10-10010 October 1997 Insp Repts 50-295/97-17 & 50-304/97-17 on 970619-0922.No Violations Noted But pre-decisional Enforcement Conference Will Be Scheduled to Discuss Violations Cited.Major Areas inspected:fitness-for-duty Related Events IR 05000295/19970181997-10-0202 October 1997 Insp Repts 50-295/97-18 & 50-304/97-18 on 970409-0730. Violations Noted.Major Areas Inspected:Engineering ML20211J7991997-10-0202 October 1997 Notice of Violation from Insp on 970409-0730.Violation Noted:Zion Station Measures to Control Matls Were Inadequate & Did Not Prevent Installation of Following,From 1992 to 1997,high Efficiency Particulate Air Filters ML20217F0861997-09-30030 September 1997 Notice of Violation from Insp on 970719-0829.Violation Noted:On 970827,engineering Contractor Operated 2C Svc Water Pump Lower Bearing Suppl Isolation valve,2SW0624,w/o Authorization from Operations Dept IR 05000295/19970191997-09-30030 September 1997 Insp Repts 50-295/97-19 & 50-304/97-19 on 970719-0829. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20217A3371997-09-12012 September 1997 Notice of Violation from Insp on 961207-970527.Violation Noted:During 1996 Unit 2 Refueling Outage,Irradiated Fuel Was Moved & Fuel Was Stored in Pool W/Less than 60 Days Decay Time & Fuel Bldg Exhaust Sys Was Operating PNO-III-97-071, on 970903,Comm Ed Announced Series of Mgt Changes & Restructuring of Nuclear Div Organization.New Site Vice Presidents at Braidwood & Quad Cities Former Plant Managers.State of Il Will Be Notified of Mgt Changes1997-09-0303 September 1997 PNO-III-97-071:on 970903,Comm Ed Announced Series of Mgt Changes & Restructuring of Nuclear Div Organization.New Site Vice Presidents at Braidwood & Quad Cities Former Plant Managers.State of Il Will Be Notified of Mgt Changes ML20217R2441997-09-0202 September 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $330,000.Violation Noted:Primary Nso Did Not Establish Power at or Less than Point of Adding Heat IAW GOP-4,step 5.21.f IR 05000295/19970161997-08-28028 August 1997 Insp Repts 50-295/97-16 & 50-304/97-16 on 970530-0718. Violations Noted.Major Areas Inspected:Operations, Maintenance & Engineering ML20216C4801997-08-28028 August 1997 Notice of Violation from Insp on 970530-0718.Violation Noted:On 970510,during Performance of OSP 97-012,section 5.58,licensee Failed to Close 3L Kiene Valve ML20211C9071997-08-27027 August 1997 EN-97-080:on 970902,notice of Proposed Imposition of Civil Penalty in Amount of $330,000 Issued to Licensee.Action Based on Three Severity Level III Violations Pertaining to Reactivity Mgt Problems & Command/Control Problems IR 05000295/19970201997-08-26026 August 1997 Insp Repts 50-295/97-20 & 50-304/97-20 on 970728-0801. Violations Noted.Major Areas Inspected:Aspects of Licensee Plant Support Performance & Specifically,An Evaluation of Effectiveness of RP Program ML20217R3411997-08-26026 August 1997 Notice of Violation from Insp on 970728-0801.Violation Noted:High Radiation Area W/Radiation Levels Greater than 1000 Mrem/Hr Was Not Locked & Personnel Did Not Have Direct Oversight of & Positive Control Over Each Entry Into Area IR 05000295/19970131997-08-15015 August 1997 Insp Repts 50-295/97-13 & 50-304/97-13 on 970404-0529. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Failure to Immediately Notify CR of Fire in Unit 1 Containment Resulting in Violation ML20217P9661997-08-15015 August 1997 Notice of Violation from Insp on 970404-0529.Violations Noted:Fire Resulted When Mechanical Maint Personnel Did Not Ensure That Adequate Natural or Mechanical Ventilation Was Established While Applying Flammable Lubricant to Rv Holes ML20149G6381997-07-17017 July 1997 Insp Rept 50-295/97-12 on 970311-0425.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering Associated W/Unit 1 Loss of Offsite Power Event That Occurred on 970311 ML20149G6341997-07-17017 July 1997 Notice of Violation from Insp on 970311-0425.Violation Noted:On 970311,licensee Identified That Procedure Did Not Exist for Responding to Loss of Offsite Power That Resulted When Unit 1 Sys Auxiliary Transformer Tripped ML20149H9961997-07-16016 July 1997 Predecisional Enforcement Conference Rept on 970703.Areas Discussed:Violations Noted in Insp Repts 50-295/97-02, 50-304/97-02,50-295/97-07 & 50-304/97-07 on 970206-0402 & 0312-0428 & Corrective Actions IR 05000295/19970151997-06-26026 June 1997 Insp Repts 50-295/97-15 & 50-304/97-15 on 970602-06.No Violations Noted.Major Areas Inspected:Licensee Plant Support Performance & Effectiveness of RP Program 1999-09-01
[Table view] |
Text
- 1-NOTICE OF VIOLATION AND PROPOSED IMPOSITION OF CIVIL PENALTY Commonwealth Edison Company Docket No. 50-295;50-304 Zion Generating Station License No. DPR-39; DPR-48 [
EA 96-355 l t
During an NRC inspection conducted on July 22 through August 22,1996, violations of NRC requirements were identified. In accordance with the " General Statement of Policy l and Procedure for NRC Enforcement Actions," NUREG-1600, the NRC proposes to impose '
a civil penalty pursuant to Section 234 of the Atomic Energy Act of 1954, as amended (Act),42 U.S.C. 2282, and 10 CFR 2.205. The particular violations and associated civil 3 penalty are set forth below:
- 1. Violations Assessed A Civil Penalty A. 10 CFR 50.59(a)(1) states, in part, that a licensee may make changes in the facility as described in the safety analysis report without prior Commission approval unless the change involves a change in the technical specification incorporated in the license or an unreviewed safety question. 10 CFR 50.59(b)(1) states, in part, that the licensee shall maintain records of changes in the facility and of changes in the facility made pursuant to this ;
section, to the extent that these changes constitute changes in the facility (
and in procedures as described in the safety analysis report. These records '
must include a written safety evaluation which provides the bases for the determination that the change does not involve an unreviewed safety question.
1
- 1. The Zion Updated Final Safety Analysis Report (UFSAR) at Section 6.3 describes the safety injection system and Figure 6.3-1 indicates ,
that there is no heat tracing installed on the safety injection (SI) pumps' minimum flow recirculation piping. j l
Contrary to the above, on March 18,1996, the licensee did not l perform an adequate safety evaluation to determine whether temporary alteration 96-014, " Installation of Heat Tracing and Insulation on the SI Recirculation Line," constituted an unreviewed safety question. Specifically, the safety evaluation was deficient because it did not provide the basis for the determination that the installation of heat tracing did not change the SI system operating characteristics. (01013)
- 2. The Zion UFSAR at Table 6.2-4 states that there is no seal water system function for containment penetration P-4. I 9703180119 970312
{DR ADOCK 05000295 PDR
~ J
Notice of Violation 2 Contrary to the above, as of October 1995, the licensee did not perform an adequate safety evaluation to determine whether the safety related plant change implemented by E22-1(2) 5 218, "MOV St-8803A/B Bypass Line Addition," constituted an unreviewed safety question. Specifically, the evaluation was deficient in that it took credit for the seal water system as a containment isolation function for penetration P-4. (01023)
- 3. The Zion UFSAR at Section 6.3.2 describes the safety injection tanks and Section 5.4.11.2 describes the pressurizer relief tank, in ;
addition, the UFSAR did not describe the acceptability of leaving temporary scaffolding in the containment during power operation. j Contrary to the above, as of November 16,1995, the licensee did not perform an adequate safety evaluation to determine whether safety evaluation 50.59/0166/95, which authorized temporary scaffolding to remain in the containment (around the safety injection tanks and in contact with the pressurizer relief tank), constituted an unreviewed safety question. Specifically, the evaluation failed to consider the effect the scaffolding could have on piping and instrumentation, pipe break effects, and/or thermal growth. (01033)
B. 10 CFR 50, Appendix B, Criterion V, " Instructions, Procedures, and Drawings," states, in part, that activities affecting quality shall be appropriate to the circumstances and shall be prescribed by documented instructions, procedures, or drawings and shall be accomplished in accordance with these instructions, procedures and drawings.
- 1. Zion administrative procedure (ZAP) 510-02, " Plant Modification Program" (Rev 5(G) dated December 19,1995), at Steps G.6.d,
" Quality Control," G.6.e, " System Engineer," G.7.c, " Modification i Coordinator," and G.7.d, " System Engineer Supervisor," required verification by each respective individual or department that the plant modification was complete prior to placing the effected equipment in service.
Contrary to the above, as of August 22,1996, the licensee failed to follow procedures, for activities affecting quality, in that the following safety-related modifications were not accomplished in accordance with ZAP 510-02. Specifically the components associated with each modification listed below were " declared operable" before the required verifications by either the Quality Control department, System Engineer, Modification Coordinator, or System Engineer Supervisor were complete. (01043)
)
^
4 Notice of Violation 3 i a. Modification E22-190-016B, "NIS source and intermediate range replacement with accident monitoring qualified instrumentation;"
s
- b. Modification E22-1(2)-93-248, " Change steam supply to
. auxiliary feed pump traps to choke traps;"
- c. Modification M22-0-84-001, " Process radiation monitor signal (OP1 A-PR29) to control room isolation and safety injection;"
and
- d. Modification M22-1(2)-84-052, " Receptacle on battery charger and test switch."
- 2. Z%. idministrative procedure (ZAP) 700-08, 0, " Problem Identification Process" (Rev 1 dated June 29,1996), at item 16 of Appendix A, required generation of Problem identification Forms (PlFs) for events or conditions identified by an assessment group.
Contrary to the above, as of August 22,1996, the licensee failed to follow procedures, for activities affecting quality, in that approximately 114 deficient conditions identified by. the UFSAR conformance review group (an assessment group) were not documented on PlFs as required by item 16 to Appendix A of ZAP 700-08. (01053)
- 3. ZAP 920-01, " Site Scaffolding Procedure" (Rev 1 dated November 7, 1995), at step F.16 requires monthly inspections of installed scaffolding.
Contrary to the above, from November 15,1995, to August 22, 1996, the licensee failed to follow procedures, for activities affecting quality, in that a monthly inspection of scaffolding installed around the safety injection accumulators was not performed as required by step F.16 of ZAP 920-01. (01063)
- 4. ZAP 500-13A, " Perform Monitoring, Evaluation, and Goal Setting Within the Maintenance Rule" (Rev 0 dated July 10), at step G requires system engineering to perform monthly updates of the material condition data base.
Contrary to the above, as of August 22,1996, the licensee failed to follow procedures, for activities affecting quality, in that the material condition data base for the Auxiliary Power system was not updated as required by ZAP-500-13A. (01073)
_ J
- .- . - - . - ~ ~ - . - - ..
- t Notice of Violation 4
- 5. ZAP 510-02, " Plant Modification Program" (Rev 5(G) dated December 19,1995), at Section G.7 requires that all drawings or diagrams affected by a design package shall be updated.
l Contrary to the above, as of August 22,1996, the licensee failed to follow procedures, for activities affecting quality, in that diagrams of safety related degraded voltage relays were not updated subsequent to relay revisions as required by ZAP 510-02. Specifically, diagrams 22E-1 -4000H, 22E-1 -4000J, 22E-2-4000H, 22E-2-4000J, 22E-1-4000C, and 22-E-2-4000C had not been revised. (01083)
- 6. ZAP 130-02, " Technical Specification Interpretation" (Rev 0 dated October 18,1995), at step G.1.h requires that a Technical Specification (TS) Interpretation (TSI) shall not change the intent of the applicable TS.
Contrary to the above, as of August 22,1996, the licensee failed to follow procedures, for activities affecting quality, in that the following TSis had not been reviewed to determine if the TSI altered the intent of the applicable TS as required by ZAP 130-02.(01093)
- a. TSI 89-03 altered the intent of TS 4.3.1.A.4.b. by allowing the use of narrow range steam generator water level to determine reactor coolant loop operability. TS 4.3.1.A.4.b. specified the use of wide range steam generator water level in determining reactor coolant loop operability.
- b. TSI 95-03 altered the intent of TS 3.13.1.A.4 by suspending residual heat removal operation for up to one hour in an eight hour period during core alterations. TS 3.13.1.A.4 requires at least one residual heat removal pump and heat exchanger be in operation during core alteration,
- c. TSI 89-02 altered the intent of TSs 3.7.2 and 4.7.2 by permitting auxiliary feedwater flowpath valve verification instead of auxiliary feedwater flowrate when verifying auxiliary feedwater pump operability,
- d. TSI 91-05 altered the intent of TSs 3.8.7.A, B, and C by increasing the time limit that the licensee can take to place the unit in hot shutdown if service water pumps become inoperable, i
. I Notice of Violation 5
- e. TSI 86-03 altered the intent of TSs 3.22.1.A,3.22.2.A, 4.22.1.A.3 and 4.22.2.A.3 by permitting a visual examination instead of an engineering evaluation for components that were attached to a snubber that had failed a functional test.
C. 10 CFR 50, Appendix B, Criterion XI, " Test Control," states, in part, that a test program shall be established to assure that all testing required to demonstrate that structures, systems, and components will perform 4
satisf actorily in service is identified and performed in accordance with written test procedures which incorporate the requirements and acceptance limits contained in applicable design documents. Test results shall be documented and evaluated to assure that test requirements have been satisfied.
Contrary to the above, the licensee failed to establish an effective testing program as evidenced by the following examples: (01103)
- 1. As of August 22,1996, the licensee's test program did not assure that all testing required to demonstrate that the following modifications would perform satisfactorily was completed prior to placing the modified systems in service.
- a. Modification E22-1-90-0168, " Replace NIS Source and Intermediate Range with Accident Monitoring Qualified Instrumentation," was placed in service in January 1994, however, the test documentation and loop calibrations for the NIS loop drawers could not be located.
l
- b. Modification E22-1(2)-93-248, " Replacement of Turbine Driven l Auxiliary Feed Pump Steam Traps," was placed in service in February 1996 without performing the testing specified in Modification E22-1(2)-93-248.
- c. Modification M22-0-84-001, " Process Radiation Monitor Signal (OP1 A-PR29) to Control Room Isolation and Safety injection,"
was placed in service in 1989 without performing the testing specified in Modification M22-0-84-001,
- d. Modification M22-1(2)-84-052, " Battery Charger Receptacle and Test Switch," was placed in service in 1986 without performing any post-modification testing.
_ _ _ . _ _ . - _ _ . . - ._ _ _ _ _ _ _ _ _ __.___.m _.m_ .
- t b
- ' Notice of Violation 6 i
a
- 2. As of August 22,1996, the emergency core cooling system full flow i test procedure TSS 15.6.84, ." Charging and Safety injection Flow I
Test" (Rev 24 dated October 25,1995), that was performed on l October 22,1995, failed to incorporate acceptance criteria to address j the Small Break Loss of Coolant Accident (LOCA) flow requirements I contained in RSA:92-217, " Zion Small Break LOCA Analysis."
i l D. 10 CFR 50, Appendix B, Criterion XVI, " Corrective Action," states, in part, j that measures shall be established to assure that conditions adverse to ]
quality, such as failures, malfunctions, deficiencies, deviations, defective '
4 material and equipment, and nonconformances are promptly identified and
!" corrected. In the case of significant conditions adverse to quality, the measures shall assure that the cause of the condition is determined and corrective action taken to preclude repetition.
Contrary to the above, the licensee f ailed to establish measures to assure that significant conditions adverse to quality are promptly identified and corrected as evidenced by the following examples (01123):
- 1. As of August 22,1996, measures were not taken to determine the cause of and correct a significant condition adverse to quality pertaining to the repetitive out of tolerance settings for the containment spray sodium hydroxide spray additive tank level indication.
- 2. As of August 22,1996, measures were not taken to correct a significant condition adverse to quality pertaining to the repetitive failures of 4KV Breaker No.1412, " Reserve Feed Breaker," for the Unit 2 Engineering Safeguard Feature Busses.
This is a Severity Level 111 problem (Supplement 1).
Civil Penalty - $100,000 ll. Violation Not Assessed a Civil Penalty 10 CFR 50, Appendix B, Criterion XIV, " Inspection, Test, and Operating Status,"
states, in part, that measures shall be established to indicate, by the use of markings or other suitable means, the status of inspections and tests performed upon individual items of a nuclear power plant. These measures shall provide for the identification of items which have satisfactorily passed required inspections and tests, where necessary to preclude inadvertent bypassing of such inspections and tests.
- e l
l l
Notice of Violation 7 l
Contrary to the above, as of August 6,1996, the following safety-related modifications did not contain measures to status tests performed upon individual items of the modifications and did not provide for the identification of items that had satisfactorily passed testing required by the modifications prior to placing them in service where necessary to preclude inadvertent bypassing of such tests.
(02014)
A. Modification E22-1-90-0168, " Replace NIS Source and Intermediate Range with Accident Monitoring Qualified Instrumentation;"
B. Modification E22-1(2)-93-248, " Replacement of Turbine Driven Auxiliary Feed Pump Steam Traps;"
C. Modification M22-0-84-001, " Process Radiation Monitor Signal (OP1 A-PR29) to Control Room isolation and Safety injection;" and D. Modification M22-1(2)-84-052, " Battery Charger Receptacle and Test Switch."
This is a Severity Level IV violation (Supplement 1).
Pursuant to the provisions of 10 CFR 2.201, Commonwealth Edison Company (Licensee) is l hereby required to submit a written statement or explanation to the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, within 30 days of the date of this Notice of Violation and Proposed imposition of Civil Penalty (Notice). This reply should be clearly marked as a " Reply to a Notice of Violation" and should include for each alleged violation: (1) admission or denial of the alleged violation, (2) the reasons for the violation if admitted, and if denied, the reasons why, (3) the corrective steps that have been taken and the results achieved, (4) the corrective steps that will be taken to avoid further l violations, and (5) the date when full compliance will be achieved. If an adequate reply is I not received within the time specified in this Notice, an order or a Demand for Information l may be issued as why the license should not be modified, suspended, or revoked or why I such other action as may be proper should not be taken. Consideration may be given to extending the response time for good cause shown. Under the authority of Section 182 of the Act,42 U.S.C. 2232, this response shall be submitted under oath or affirmation.
Within the same time as provided for the response required above under 10 CFR 2.201, the Licensee may pay the civil penalty by letter addressed to the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, with a check, draft, money order, or electronic transfer payable to the Treasurer of the United States in the amount of the civil penalty proposed above, or the cumulative amount of the civil penalties if more than one civil penalty is proposed, or may protest imposition of the civil penalty in whole or in part, l by a written answer addressed to the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission. Should the Licensee fail to answer within the time specified, an order imposing the civil penalty will be issued. Should the Licensee elect to file an answer in accordance with 10 CFR 2.205 protesting the civil penalty, in whole or in part, such 1
1 1
a e Notice of Violation 8 answer should be clearly marked as an " Answer to a Notice of Violation" and may: (1) deny the violations listed in this Notice, in whole or in part, (2) demonstrate extenuating circumstances, (3) show error in this Notice, or (4) show other reasons why the penalty should not be imposed. In addition to protesting the civil penalty in whole or in part, such answer may request remission or mitigation of the penalty, l l
In requesting mitigation of the proposed penalty, the factors addressed in Section VI.B.2 of the Enforcement Policy should be addressed. Any written answer in accordance with 10 CFR 2.205 should be set forth separately from the statement or explanation in reply pursuant to 10 CFR 2.201, but may incorporate parts of the 10 CFR 2.201 reply by specific reference (e.g., citing page and paragraph numbers) to avoid repetition. The I attention of the Licensee is directed to the other provisions of 10 CFR 2.205, regarding the )
- procedure for imposing a civil penalty. ;
i Upon failure to pay any civil penalty due which subsequently has been determined in i accordance with the applicable provisions of 10 CFR 2.205, this matter may be referred to the Attorney General, and the penalty, unless compromised, remitted, or mitigated, rnay be l collected by civil action pursuant to Section 234c of the Act,42 U.S.C. 2282c. j The response noted above (Reply to Notice of Violation, letter with payment of civil i penalty, and Answer to a Notice of Violation) should be addressed to: James Lieberman, l Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, One White Flint l North,11555 Rockville Pike, Rockville, MD 20852-2738, with a copy to the Regional l Administrator, U.S. Nuclear Regulatory Commission, Region Ill.
Because your response will be placed in the NRC Public Document Room (PDR), to the extent possible, it should not include any personal privacy, proprietary, or safeguards ,
information so that it can be placed in the PDR without redaction. If personal privacy or i proprietary information is necessary to provide an acceptable response, then please provide l a bracketed copy of your response that identifies the information that should be protected i l and a redacted copy of your response that deletes such information. If you request withholding of such material, you must specifically identify the portions of your response that you seek to have withheld and provide in detail the bases for your claim of withholding (e.g., explain why the disclosure of information will create an unwarranted invasion of personal privacy or provide the information required by 10 CFR 2.790(b) to support a request for withholding confidential commercial or financial information). If safeguards information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21.
Dated at Lisle, Illinois, this 12th day of March 1997 l