Notice of Violation from Insp & Investigation Completed on 981112.Violation Noted:From Approx July,1997 to 980122,SGI Was Not Stored in Locked Storage Container While Unattended
ML20205P221
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 04/09/1999
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20205P210 List:
References
50-295-98-02, 50-295-98-2, 50-304-98-02, 50-304-98-2, EA-98-558, NUDOCS 9904200082
Download: ML20205P221 (1)


Text

.

l 1

NOTICE OF VIOLATION Commonwealth Edison Company Docket Nos 50-295; 50-304 Zion Station License Nos. DPR-39; DPR-48 Units 1 and 2 EA 98-558 During an NRC inspection and an NRC investigation concluded on November 12,1998, a violation of NRC requirements was identified. In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," NUREG-1600, the violation is listed below:

10 CFR 73.21(d)(2) requires, in part, that while unattended, Safeguards Information will be stored in a locked security container.

Contrary to the above, from approximately July 1997 to January 22,1998, Safeguards information was not stored in a locked storage container while unattended. Specifically, a lead electrical designer willfully stored electrical design drawings, containing Safeguards information, in open packages on the floor of his work cubicle in the Design Engineering Department.

(01013)

This is a Severity Level lil violation (Supplement lil).

The NRC has concluded that information regarding the reason for the violation, the corrective actions taken and planned to correct the violation and prevent recurrence and the dates when full compliance was achieved is adequately addressed on the docket in NRC Inspection Report Nos. 50-295/98002/DRS); 50-304/98002(DRS) and in a March 18,1999, letter from Comed.

However, you are f quired to submit a written statement or explanation pursuant to 10 CFR 2.201, if ti- description therein does not accurately reflect your corrective actions or your position. In th. r. .se, or if you choose to respond, clearly mark your response as a " Reply to a Notice of Violath..., cA 98-560," and send it to the NRC Document Control Desk, Washington, DC 20555, with a copy to the Regional Administrator and the Enforcement Officer, U.S. Nuclear Regulatory Commission,801 Warrenville Road, Lisle, IL 60532-4351 within 30 days of the date of the letter transmitting this Notice of Violation (Notice).

If you contest this enforcement action, you should also provide a copy of your response, with the basis for your denial, to the Director, Office of Enforcement, U.S. Nuclear RSodatory Commission, Washington, DC 20555-0001.

If you choose to respond, your response will be placed in the NRC Public Document Room (PDR). Therefore, to the extent possible, the response should not include any personal privacy, proprietary, or safeguards information so that it can be placed in the PDR without redaction.

In accordance with 10 CFR 19.11, you may be required to post this Notice within two working days.

Dated this 9th day of April 1999

~