ML20133B054
Text
_
e.
pse uoy
,,s jo,,
UNITED STATES y'
g NUCLEAR REGULATORY COMMISSION WASHING TON, D. C. 20555 k..... /
March 16, 1984 NOTE TO:
H. Denton II FROM:
T. Novak
SUBJECT:
GRAND GULF TECH SPECS 2
Attached is a listing of the G tech spec changes that have been identified in the following four documents:
1.
EGG-EA-6542, " Grand Gulf Nuclear Power Plant Audit of Nuclear Plant Technical Specifications," March 1984, EG&G Idaho, Inc.
2.
NRC draft inspection report No. 50-416/84-06.
Final issued March 13, 1984 3.
Memo to Eisenhut from Lewis, " Comments on Draft Appendix A Technical Specifications, Grand Gulf Ilnit 1. Docket No. 50-416," February 9,1984.
4.
Memo to the Commission from Dircks, " Grand Gulf Technical Specification Changes," February 29, 1984 To date we have not been informed of any items found from the most recent MPt.L review effort described in the March 9th meeting with the staff.
The NOTES describe the key to the tables.
I have also attached a suneary table of the numbers that come out of this listing.
In addition, the licensee has identified at'out 100 additional items mostly from an MPAL review performed during February 1984.
These items were not pro-vided to the staff untii 3/14/84 in a meeting with the licensee. Additionally, we have not considered the responses from the tech review branches in response to your memo of 2/24/84.
The Grand Gulf reactor has been critical for less than 50 days over which time it has accumulated about 20 Effective Full Power Hours nf operation.
P
) ~):[%,u Thomas M. Novak, Assistant Director for 1.icensir.c Division of Licensing cc:
E. Case D. Eisenhut f
(
8507200220 850515 PDR FOIA BELL 84-459 PDR.
M l
GRAND GULF TECH SPEC ITEM SUMitARY UNDER LICENSEE REQUEST FOR CATEGORY ISSUED DENIED UNDER NRC REVIEW CONSIDERATION ADDITIONAL INFORMATION TOTAL
,5 1
43 8
14 6
71 2
18 4
8 22 52 3
64 12 12 22 1
111 4
7 1
8 132 24 35 50 1
242 l
l I
Sheet 1
of 1~
NOTES (a) Source documents are designated; L (Date) which indicates a licensee request for amendment change submitted by letter on the date indicated in parentheses; NRC (02/09/84) which indicates Region II and MRR recommendation for char.ces after second " proof-and-review" of effective Technical Specifications as of October 4,1983, (R. C. Lewis mero 02/09/84); RII (03/09/84) which indicates a Draft of RI! Inspection Report No. 50-416/84-06, received by NRR 03/09/84; and EGAG (03/84) which indicates report of an audit by EGAG of consistency of Technical Specifications re instrumentation, ECCS, containment systems, and electrical power systems with the FSAR and SER.
d (b) Priority 1 Needed Prior to exceeding 5% power Priority ? - Needed during power escalation Priority 3 - Needed Prior to cperation indicated in parentheses, (for example, refueling) or desirable to simplify implementation and inspection (c) Request No. 14 in licensee's letter dated 04/07/83 was withdrawn (d) Request No. 4 in licensee's letter dated 06/14/83 was withdrawn (e) Pecuest No. 3 in licensce's letter dated 06/29/83 was withdrawn (f) Reauest t:o. 3 in licensee's letter dated 07/11/83 was withdrawn (g) Several requests in licensee's letter dated 09/09/83 have been superseded by subsequent requests; flo. 20 was superseded by a submittal dated 10/07/83, and No. 35 was superseded by a submittal dated 01/18/84. Request
!!o. 34 was withdrawn.
I Sheet 1
of i
l
[
GRAND GULF - 1 TECPt!ICAL SPECIFICATION CPANGES Since Issuance of Low Power License, June 16, 1982 I.
Category (1) Editorial or r.cnenclature corrections Description Source (a)
Priority (b)
Status Chance reference from Drywell to L (03/24/83)
N/A Issued in Amendment 7 Containment Correct Test Line Number for PHR C L (03/24/83)
N/A Issued in Amendment 7 Test Line Delete reference to RCIC and correct L (03/24/83)
N/A Issued in Amendment 7 description of Head Spray valve Correct reference to Scram Insertion L (03/24/83)
N/A Issued in Amendment 7 Time action statement Correct nur.ber of flow rate measure-L (03/24/83)
N/A Issued in Amendment 7 r.ent devices Add inadvertently or.itted definition L (03/24/83)
N/A Issued in Amendment 7 of Purge Frequency Correct valve description of fuel L (03/24/83)
N/A Issued in Amendment 7 Handling Area Ventilation System Dampers
I Sheet 2
of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Sirce Issuance of Low Power License, June 16, 19P.2 I.
Category (1) Editorial or nomenclature corrections a)
Priority (b)
Status Description Source Correct range of instruments for Radia-L (03/24/83)
N/A Issued in Amendment 7 tion Mcritoring Instrumentation Add inadvertently omitted Action 80 in L (03/?4/R3)
N/A Issued in Amendment 7 Yable 3.3.7.5-1 Correct designation of primary contain-L (03/74/83)
N/A Issued in Amendment 7 ment isolation function Revise Control Foom Block Instrumenta-L (03/24/83)
N/A Issued in Amendment 7 tion APPM surveillance requirements Correct Seismic Instrumentation Table L (03/?4/R3)
N/A Issued in Amendment 7 designation of seismic trigger Delete reference to incorrect ODCM L (03/24/83)
N/A Issued in Amendment 7 figure in Liquid Waste Treatment Revise audit procedures of administra-L (03/?4/83)
N/A Denied tive controls
Sheet 3
of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 198?
1.
Category (1) Editorial or nemenclature corrections fa)
Priority (b)
Description Source Status Delete reference to section regarding L (04/07/83)IC)
N/A Issued in Amendment 7 reporting of limits exceedino in tanks ont existing at GG Change notation for verification of L(04/07/83dC N/A Issued in Amendment 7 core flow to be consistert with actual requirements Correct reactor vessel material with-L (04/07/83)ICI N/A Issued in Amendment 8 drawal schedule Delete ** reference in LPCI Pump B L (03/07/83)(c)
N/A Issued in Amendment 7 I
start tire delay relay Iblete reference to footonte ## regard-L (03/07/83)IC}
N/A issued in Amendment 7 l
ing tioe delay for the Differential l
Flow-High Trip function of PWCU 1
Correct surveillance requirement to L (03/07/83)ICI N/A Issued in Amendment 8 recuire testing of the system in accordance with PG 1.108
!blete reference to a non-existing note L (03/07/83)
N/A Issued in Amendment 7 i
in Table 4.3.7.11-1 Delete # footnote of TS 3.5.1 L (04/07/83)
N/A Issued in Amendment ?
Correct reference of paragraph b of L (04/07/83)
N/A Issued in Amendment 7 4.4.7 L
Shtet 4
of GPAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1987 I.
Category (1) Editorial or nonenclature corrections Description Source *)
Priority (b)
Status I
Review TS 6.5.2.8 to giva audit respons-L (04/07/83)
N/A Issued in Amendment 8 ibility to the Manager of OA and to reassign resconsibility of evaluation to staff performance Revise Sealed Source Contanination L (04/75/83)
N/A Issued in Amendments 7 A 8 reouirec:ents (2)
Correct notes and statements on several L (06/09/83)
N/A Issued in Amendment 9 TS regarding handling of irradiated fuel assemblies Pevise footnotes on Table 3.3.2-1 to L (06/09/83)
N/A Issued in Amendment 8 reflect correct logic for several trip functions Add the unit seconds to the resperse L (06/09/83)
N/A Issued in Amendment 8 tir.es for ECCS systems Revise Radioaction Monitoring Instru-L (06/09/83)
N/A Issued in Amendment 8 u rtistion to accurately reflect nreenclature t
[
Sheet 5
of l
GRAND GULF - I TECHNICAL SPECIFICATION CHANGES l
Since Issuance of Low Power License, June 16, 1982 1.
Category (1) Editnrial or nomenclature corrections Ibscription Source (a)
Priority Status I
Pevise footnote af on the calibration L (06/09/83)
N/A Issued in Amendment 8 of the offgas Post-treatment monitors Revise footnote for Radiation Monitor-L (06/14/83)
N/A issued in Amendment 8 iag Instrurentation to accurately reflect which system isolates Revise the drywell purge subsystem flow-L (06/14/83)
N/A Issued in Amendment 8 rate C.wnge a the GG corporate structure L (06/14/83)
N/A Denied Pevise several TS to reference the L (06/14/83)
N/A Issued in Amendment 8 correct Figure 5.1.3-1 i
?+~ g SGTS and Control Poom Emernency L (06/?3/83)
N/A Denied fi.tration Systen, respectively, to celete reference to ANSI h510-1975 Perise Drywell Post-LOCA Vacuum Breakers t (06/73/83)
N/A Issued in Amendment 8
Shee2 6
of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Sirce Issuance of Low Power License, June 16, 198?
I.
Category (1) Editorial or never.clature corrections Description Source (a)
Prioritv(b)
Status Pevise to change the diesel generator L (06/23/83)
N/A Denied load testing criteria Revise Motor Operated Thernal Overload L (06/?3/83)
N/A Denied Protection l
Fevise Accident Penitorino Instrumenta-L (06/?3/83)
N/A Denied tion to specify an alternate method for calibration of the contaircent/
drywell area radiation monitors Revise Accident Ponitoring Instrumenta-L (06/?3/83)
N/A Denied tion to change the calibration fre-c,uency nf the contairwet and drywell hydrcgen conitors Develcped new TS for Eir.bankr.ent L (06/?9/83)I*
N/A issued in Amendment 8 52 ability Provide ar. exception to Spe-cification L (07/!!/83)
N/A Denied 4.0.4, for TS for Control Pod Oper-t chility
Sheet 7
of
~.
GRAND GULF - 1 TFCHNICAL SPECIFICATION CHANGES Since Issuance of Low Power Licerse, June 16, 1982 I.
Category (1) Editorial er nomenclature corrections 1
Description Source
- Priority (b)
I Status Revise Fire Cetection Instrueentation L (07/19/83)
N/A Issued in Amendcent 9 to change the crder of the Table i
Revise DPS Instrumentation to correct L (08/01/83)
N/A Issued in Amendment 0 i
existing note (b) to clarify tise daily channel check from APFF. Flow Biased l
Sirulated Thermal Power-Pigh 1
l Revise Yard Fire Hydrants and Associated L (08/01/83)
N/A
!ssued in Amendment 9 i
Pydrant Pose Hcuses to correct the elevaticr.s Pevise Fire Detection Instrurentation L (08/01/83)
N/A Issued in Amendment 9 to establish ar. alternate cethod of monitrrir.g for fire in the main steam t ur.r,el i
Pevise PPS Electric Power thr.itcring L (C8/01/83)
H/A Issued in Amendment 9 to rale the format consistent Revise Safety Review Conaittee, to L {08/01/83)
N/A Issued in Amendment 9 reflect recer.t changes in corporate structure l
I Sheet 8
of l
GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 i
(
f.
Category (1) Editorial or ocmenclature corrections l
l Scurce *)
Priority Status I
l Lescription Pevise Fire Detection Instrumentation to L (09/09/83)f9 1
Under review by NRR order the table L (09/09/83)I9}
l Under review by NRR Pevise Fadiation T.onitorir.9 Instrumenta-tion to include an inadvertently caitted minicum channels operable requirement Prise ECCS Actuatien Instrumentation to L (09/09/83)I9 3
Under review by NPR delete a footnote Reeise AC Sources-Shutdown to clarify the L (09/09/R3)I9I 3
Under review by NRR crerability requirements Reeise Atnosphere (cntrol to update the L (09/09/83) 9 3
Under review by NRR effective revision date of P.G. 1.7 Revise Suppressed Pool to correct listed L (09/09/83) 1 Urder review by NRR recuired suppression pool water levels and correspondiro volum s
I I
Sheet 9
of l
l GPAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1987 i
Category (1) Editorial or nerenclature corrections Lescription Scurce(a)
Priority Status D
Pevise Isolation Actuation Instrurenta-L (09/09/83) 3 Under review by NRR tien to correct the trip retpoints Pevise Ar.rual Peports to include f.UPEG-L (09/09/83) 1 Under review by NRR C660 requirements Pevise Motor Operated Yalves Theral L (09/09/83) 1 Under review by NRR Ocerload Protection to correct two
?ppographical errors Revise AC Sources-Operatirg to correct
- L (09/09/83) 1 Under review by NRR footnote Revise PPS Instrurentation to change L (09/09/83) 3 Under review by NRR Action 2 to verify all insertable control rocs Revise ECCS Actuation Instrucentation L (09/09/83) 1 linder review by NRR to add inadvertently omitted notation
I Sheat 10 of l
GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 I.
Category (11 Editorial or nomenclature corrections Priority (b) 3 Description Scurce Status
?evise Unrestricted Area Boundary for L (09/09/83) 3 Under review by NRR
-Gaseous Effluent and for Liquid Effluents, tn change the terminology Pevise Record Retentinn tn changa the L I.09/09/03) 3 Under review by NRR reference to the snubber Tables Changes setpcints for ECCS Instrumenta-L (Before C0A)
N/A Issued in Amendment 5 tion Corrects Table reference in Section L (Before C0A)
N/A Issued in Amendment 5 4.8.4.1 Changes clarifying statecent for drywell L (Before C0A)
N/A Issued in Amendment 5 vacuum breaker footnote AC Sources Shutdown NRC (02/09/84) 3 Under consideration by Licensee Plant Safety Review Coramittee NRC (0?/09/84) 3 Under consideration by Licensee
m l
Sheet 11'.of GRAND GULF.- 1-TECHNICAL SPECIFICATION. CHANGES Since Issuance of Low Power License, June 16, 1982 j
I.
Category.(1) Editorial or nomenclature corrections l'
Description Source (a)
Priority (b)
Status Safety Review Comittee NRC (02/09/84) 3'
.Under consideration by Licensee.
s SGTS Surveillance NRC (02/09/84) 3 Under consideration by O censee.
AC Sources NRC (02/09/84) 3 Under consideration by Licensee Records NRC (02/09/84) 3 Under consideration by Licensee Valve Number Error RII (03/09/84) 3 Under consideration by Licensee
I
. Sheet l'
of H
GRAND GllLF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of. Low Power License, June 16, 1982 II. Category _(2) Consistency within technical specifications
. Description-Source (a):
Priority ')
O Status Correct setpoint of RPCS allowable L (03/24/83):
N/A.
Issued in Amendment 7'
.~
-[ -
value Correct Main Steam Line High Padiation L (03/24/83)
N/A issued in Amendment'J Trip and Allcwable Value Setpoint-Change
- notes for Operation Condition L (03/24/83)
N/A Issued in Amendment.8 4 and 5 Add o* notation which clarifies thatL L (04/07/83)
N/A Issued in Amendment 7 certain values will he determined during startup testing Change
- regarding applicability of L (04/07/83)
N/A Issued in Amendment 7 i
surveillance of offgas Post-Treatment-Monitors Correct requirements to provent unsafe L (04/07/83)
N/A.
Denied movements of control rods
... - ~.
Sheet 2-of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16. 198?'
II. Category (2) Consistency within technical specifications l
Description Source ")
Priority (b)
I Status Pevise electrolyte level'and specific
.L (04/25/83)
N/A Issued in Amendment 12 gravity for the pilot cells of the fire pump diesel j'
Revise Ultimate Heat Sink to include L (06/09/83)
N/A Issued in Amendment 8 j,
which are applicable with one SSW j
cooling tower basin inoperable i
l Peuise TS surveillance requirements for L (06/09/83)
N/A Denied fire doors i
l Revise APPM Setpoints to'make the set-L (06/14/83)
N/A Issued in Amendment 8 points and allowable values consistent Revise the surveillance requirements for L (06/14/83)
F/A Denied i
Recirculation Loops Provide an example to Specification L (06/14/83)
N/A Issued in Amendment 10 4.0.4 for Safety / Relief Valves II
Sheet 3
of' GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since issuance of' Low Power License, June 16, 1982 d
II. Category (?) Consistency within technical specifications Description Source ")
Priority (b)
Status I
Revise AC Sources-Operating to correct L (06/23/83)
N/A Issued in Amendment 8 the required level of fuel in the i
Diesel Generator-13 day fuel tank f
Revisa ECCS Actuation Instrumentation L (06/?9/83)
N/A Issued in Amendment 8 to delete footnotes referencing injection valve interlocks l
.t Revise Radiation Monitoring Instrumenta-L (06/29/83)
N/A Denied tion and Radiactive Gaseous Effluent 3
Monitoring Instrumentation, respec-tively, to make the requirements for the pre-treatment and post-treatment offqas radiation monitors consistent i
Revise Suppression Pool to correct the L (06/29/83)
N/A Issued in Amendment 8 number of required channels per-division for suppression. pool water level. instrumentation Revise Fire Rated Assemblies. to make the L (08/01/83)
N/A Issued in Anendment 9 surveillance reauirements for fire i
doors consistent 1
e
.~
I Sheet 4
of
. GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982-II. Category (2) Consistency within technical specifications 4
Source (a)
Priority (b)
Status Description Revise Accident Monitoring Instrumenta-L (08/01/83)
N/A Issued in Amendment 9 tion to specify an alternate metand for calibratinn of the containment /
drywell area radiation monitnrs Provide exemption tn Specification 4.0.4 L (08/01/83)
N/A Issued in Amendments 9 and 10 for Control Rod Operability Revise Radiation Monitoring Instrumenta-L (09/09/83) 3 Under review by NRR tion and Radioactive Gaseous Effluent Monitoring Instrumentation to provide for consistency Revise Standby Service Water System to L (09/09/83) 1 Under review by NRR make this TS LC0 more consistent Revise Isolation System Instrumentation L (09/09/83) 3 lInder review by NRR Response Time to change footnnte ##f to address time delay required to avoid spurious isolation of the system
Sheet 5
of
~.
GRAND GULF - 1 TECHNICAL SPECIFICATION CHAT!GES Since Issuance of Low Power License, June 16, 1982
- 11. Category (2) Consistency within technical specifications Source (a)
Priority (h)
Status Description Revise RPS Instrumentation and Isolation L (09/09/83) 3 Under review by NRR Actuation Instrumentation to not require an inoperable channel be placed in the tripped condition Revise ECCS Actuation Instrumentation to L (09/09/83) 1 Under review by NRR correct LPCI Pump B and C Discharge Pressure-High allowable value Revise Control Pod Maximum Scram Inser-L (09/09/83) 3 Under review by NRR tion Times and Control Rod Scram Accumulators, to provide an examption from Specification 3.0.4 Revise Area Temperature Monitoring to L (09/09/83) 3 Under review by NRR delete the Eauipment not Operating Temperating Limit to be consistent with the actual requirement Revise Source Range Monitors and Control L (09/17/83)
N/A Issued in Amendment I?
Pod Block Instrumentation to lower the minimum SRM count rate i
~.
s.
I Sheet 6
of-GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since issuance of Low Power License, June.16,1982
- 11. Category (2) Consistency within technical ' specifications Source (a)
Priority (b)
Status Description Changes low pressure alarm setpoint for L (Before C0A)
N/A Issued in Amendment 3
" keep-filled" system Change to reflect credit for one recir--
L (Before C0A)
N/A Issued in Amendment 5 culation pump in operation AC Sources Soutdown (3)
NRC (02/09/84) 3 Under consideration by Licensee Spent Fuel Storage Pool Temperature NRC (02/09/84) 3 Under consideration by Licensee Embankment Stability NRC (07/09/84) 3 Under consideration by Licensee Isolation Actuation Instrumentation NRC (02/09/84) 3 Under consideration by Licensee Control Rod Block Instrumentation NRC (02/09/84) 3 Under consideration by Licensee Source Pange Monitors NRC (07/09/84) 3 Under cnnsideration by Licensee
Sheeti 7
of.
GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low. Power License, June 16, 1982 II. Category-(2) Consistency within technical specifications I
Description Source (a)
Priority (b)
Status Refueling Instrumentation NRC (02/09/84) 3 Under consideration by Licensee Control Rod Operability NRC (02/09/84) 3 Under consideration by Licensee Drywell Purge NRC (02/09/84) 3 Under consideratinn by Licensee 4
Chemistry-Conductino Pecorders NRC (02/09/84) 3 Under consideration by Licensee Pedwaste Reporting NRC (02/09/84) 3 Under consideration by Licensee Jet Pumps NRC (02/09/84) 3 Under consideration by Licensee Reactor Coolant System NRC (02/09/84) 1 Under consideration by Licensee Redundant Channel Trip Systems NRC (02/09/84) 3 Under consideration by 1.icensee RCS Leakage NRC (02/09/84) 3 Under consideration by Licensee
Sheet.
8 - of GRAND GULF TECHNICAL SPECIFICATION CHANGES Since issuance of Low Power License, June 16,,1982 II. Cate90ry (2) Consistency within technical specifications I
I8)
Priority (b)
Status Description Source Recirculation loop Flow NRC (02/09/84) 3-
'Jnder consideration by Licensee-Chemistry-Conductivity. and Chloride NRC (02/09/84) 3 Under consideration by Licensee Recirculation Loop FCV Movement NRC (02/09/84) 3 Under consideration by Licensee Liould Effluents Concentration NRC (02/09/84) 3 Under consideration by Licensee E0C Recirculation Pump Trip NRC (02/09/84) 3 Under consideration by Licensee APRii Setpoints L (02/27/84) 1 Under review by NRR TIP and Process Computer NRC (02/09/84) 3 Under consideration by Licensee Control Rod Scram Accumulator NRC (02/09/84) 3 Under consideration by Licensee
~
Sheet' 1
of.
GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 III. Category (3) Conformance to as-built plant Description Source ^)
Priority (b)
Status
-Delete T!P System TS L (03/24/83)
N/A Issued in Amendment 7 Clarify requirements for verifying L (03/24/83)
N/A Issued in Amendment 7 energi:ation of electrical buses
~ Change Trip Setpoint of Reactor Pump L (03/24/83)
N/A Issued in Amendment 8 Petors Trip Breakers to reflect locked motor current Change specific gravity limits to be L (03/2a/83)-
N/A Issued in Amendment 8 consistent with manufacturers recom-mendations Delete erroneous symbols from MSIV L (03/24/83)
N/A Issued in Amendment 7
!solatien Table Delete incorrect requirement for L (03/24/83)
N/A Issued in Amendment 7 automatic termination of release by ?oble Gas Activity Monitor
. Sheet 2
of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1082 III. Category (3) Conformance to as-built plant t
Description Source ^)
Priority (b)
I Status I
Change reference of generator to engine L (03/24/83)
N/A Issued in Amendment 7 to reflect actual component tempera-ture measured and correct list of Diesel Generator trip features
%dd additional valves to Motor Thermal L (03/24/83)
N/A Issued in Amendment 8 Over1nad Table Change Fuel Transfer System to reflect L (03/24/83)
N/A Issued in Amendment 7 requirer.ents for horizontal Fuel Transfer System Correct Reactor Mode Switch list of L (03/24/83)
N/A Issued in Amendment 7 interlocks Change note in Isolation Ac'tuation L (03/24/83)
N/A Issued in Amendment 7 instrumentation to reflect correct RWCU valves closed by SLCS actuation Correct Meterological Instrumentation L (03/24/83)
N/A Issued in Amendment 7 Table to reflect actual elevations of instruments i
Sheet 3
of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 111. Category (3) Conformance to as-built plant Description Source ( )
Priority (b)
Status Delete footnote to composition of SRC L (03/24/83)
N/A Denied regarding voting authority of a member Correct Area Temperature Monitoring L (04/07/83)
N/A Issued in Amendment 7 Tables to reflect temperatures specified for equipment qualification Delete requirement for testino of bypass L (04/07/83)
N/A Issued in Amendment 7 function of HEPA and charcoal filters Delete requirement to test post-LOCA L (04/07/83)
N/A Issued in Amendment 7 vacuum breakers by lever arm actuation Change Diesel Generator desien start L (04/07/83)
N/A Issued in Amendment 7 time from 13 seconds to 10 seconds Add dryer storage area to areas required L (04/07/83)
N/A Issued in Amendment 7 monitors
-= -.
. ~
f v
Sheet 4-of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since issuance of Low Power License, June 16, 1987 j
III. Category (3) Conformance to as-built plant Description Source (a)
Priority (b)
Status Delete reonirement to leak rate test the L (04/07/83)
N/A issued in Amendment 7 4
portion of the Combustible Gas Control
{
System outside containment j
2 Correct surveillance requirement to L (04/07/83)
N/A Denied ensure largest single inad is applied t
3~
during diesel generator testing j
.t Delete the requirement to verify that L (04/25/83)
N/A Denied each automatic valve in the finw path of the fire suppression water system activates to its correct position i
I Revise testing of the electro-thermal L (04/25/83)
N/A Denied links to allow verification of actual signal being received i
l
]
Revise listing of fire hose stations L-(04/25/83)
N/A Issued in Amendment 7 Revise listing of yard fire hydrants L (04/25/83)
N/A Denied
-and associated hydrant hose houses 4
Sheet
-5 of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 1
Ill.
Category (3) Conformance to as-built plant Description Source (a) b)
Priority Status Delete ionization smoke detectors in the L (04/25/83)
N/A Denied auxiliary building main steam tunnel 4
Correct trip setpoint and allowable L (06/09/83)
N/A Issued in Amendment 8 value'or Reactor Vessell Dome Pressure High instrument Revise surveillance testing of the LSS L (06/09/83)
N/A Issued in Amendment 8 Panel Revise the tolerance specified for the L (06/09/83)
N/A Issued in Amendment 9 SPVs I
l 1
Revise the tolerance specified for one L (06/09/83)
N/A Issued in Amendment 9 SRV low-low set function 4
Pevise surveillance requirements for air L (06/09/83)
N/A Issued in Amendment 8
]
lock door seal systems instrumentation Revise surveillance on SGTS actuation L (06/09/83)
N/A Issued in Amendments 8 & 9 s
j signals to include m5nual initiation 1
m Sheet 6
of GRAND GllLF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 III. Category (3) Conformance to as-built plant t
Description Source (a)
Priority (b)
Status Pevise surveillance Control Room L (06/09/83)
N/A Issued in Amendments 8 & 9 emergency filtration system actuation signals to include manual initiation Revise listing of snubbers L (06/09/83)
N/A Issued in Amendment 8 i
Revise the setpoint tolerances of the-L (06/09/83)
N/A Denied RPS electronal protection assembly 4
i Revise Refueling Platform to address the L (06/09/83) 3 Requested Additional Information equipment that may be used during fuel assembly and control rod handling 1
Revise the trip setpcints and allowable L (06/09/83)
N/A Issued in Amendment 8 values of several instruments for Isolation Actuation Instrumentation Revise the trip setpoints and allowable L (06/09/83)
N/A Issued in Amendment 8 values of several instruments for ECCS Fctuation Instrumentation e
Sheet 7
of
' GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 III. Category (3) Conformance to as-built plant Description Source (a)
Priority (b)
Status Revise the blower flow rates for the L (06/09/83)
N/A Issued in Amendment 8 inboard and outboard systems of the MSIV Leakage Control System Revise the specified pressure drop L.(06/14/83)
N/A issued in Amendment 8 across the HEPA filters of the SGTS Revise Spray / Sprinkler Systems to L (06/14/83)
N/A Denied include additional systems Revise Onsite AC Power Systems to delete L (06/14/83)
N/A Issued in Amendment 8 the requested testing of the normal circuit to alternate circuit automatic transfer feature Revise the load shedding requirements to L (06/14/83)
N/A Issued in Amendment 9 be verified on Diesel Generator 13 Revise ECCS Actuation Instrumentation to L (06/23/P3)
N/A Issued in Amendment 8 change the trip setpoint and allowable values-
1
.. Sheet 8
of GRAND GULF - 1 TECHNICAL, SPECIFICATION CHANGES Since issuance of Low Power License, June 16,11982 III. Category (3) Conformance to as-built ' plant Description Source (a)
Priority (b)
Status Revise the EOC-RPT' trip setpoints and L (06/23/83)
N/A Issued in Amendment 8 allowable values for the Turbine Stop Valve Closure l
Revise the load profile of the 125v L (06/23/83)
N/A Issued in Amendment I?
Division 2 battery system Revise E0C-RPT System and its bases, to L (06/?3/83)
N/A Issued in Amendment 12 correct the resporse time values Revise the ## notation in Tables for L (06/23/83)
N/A Issued in Amendment 12 isolation Actuation Instrumentation Provide 4.0.4 exception for Centrol Rod L (06/23/83)
N/A Issued in Amendment 9 Maximum Scram Insertion Times Revise Radiation Monitoring Instrumenta-L (06/23/83)
N/A Issued in Amendment 9 tien to correctly reflect the minimum operable channels per trip system
a Sheet 9-of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since issuance of Low Power License,. lune 16, 1982 4
III. Category (3) Conformance to as-built plant i
Description Source (a)
Priority (b)
Status Revise ECCS Systens to correc the header L (06/23/83)
N/A Denied I
p instrumentation setpoint Revise ECCS Systems to change the LPCI L (06/23/83)
N/A Denied system low pressure setpoint Correct numerous typographical and L (06/23/83)
N/A Issued in Amendment 9 editorial errors Revise Containment and Drywell Isolation L (06/?3/83)
N/A Issued in Arendment 10 Valves to delete the minimum flow valves associated with the RHR.iockey pumps Revise Isolation Actuation Instrumenta-L (06/29/83)
N/A Issued in Amendment 8 tion to correct trip setpoints and allowable values to reflect instru-ment loop' inaccuracies Revi,se ECCS Actuation Instrumentation L (06/29/83)
N/A Issued in Amendment 8 to change the LPCI pump A and LPCI B start time delay
_i
.~.
Sheet 10 of i
GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES-Since Issuance of Low Power License, June 16, 1982 III. -Category (3) Conformance to as-built plant Description
. Source ")
Priority (b)
I Status Revise Primary Containment Penetration L (06/29/83)
N/A Issued in Amendment 9-
,L Conductor Overcurrent Protective i
Devices to correct terminology and add breakers Revise ECCS Systems-0perating to correct L (06/29/83)
N/A-Issued in Amendment 9 test line pressure requirements Revise Control Rod Operability to L (06/29/83)
N/A Issued in Amendment 8 correct conditions required to perform surveillance of the SUV Revise Secondary Containment Integrity L (06/29/83)
N/A Issued in Amendment 8 to change the required negative pres-sure requirement Revise Safety / Relief Valves to include L (07/11/83)
N/A Issued in Amendment 12 a footnote which applies to the 10 relief valves
Sheet-11 of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES-Since Issuance of Low Power License, June 16, 1982 III. Category (3) Conformance to as-built plant i
Description Source (a)
Priority (b)
Status Revise isolation Actuation Instrumenta-L (07/11/83)
N/A Denied tion Containment'and Drywell Isolation Valves and Secondary Containment Ventilation System Automatic Isolation Dampers / Valves Pevise AC Sources-0perating to change L (08/01/83)
N/A Issued in Amendment 9
~.
the loads specified for the largest single load Revise CO2 Systems and Falon Systems to L (08/01/83)
N/A Issued in Amendment 9 establish appropriate surveillance reouirements Revise Spray and/or Sprinkler Systems L (08/01/83)
N/A Issued in Amendment 9 to include additional systems Revise AC Power Systems Operating to L (08/01/83)
N/A Issued in Amendment 9 correct the periodic testing of the diesel generators
-Sheet 12 of GRAND GULF TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 III. -Category (3)'Conformance to as-built plant Description Source (a)
Priority (b)
Status Revise Accident Monitoring Instrumenta-'
L (08/01/83)
N/A Issued in Amendment 9-tion to change the channel calibration frequency.
Revise the bases for Secondary Contain-L (08/01/83)
N/A Denied ment Control Room Emergency Filtration System Revis? ECCS Actuation Instrumentation L (08/01/83)
N/A Issued in Amendment 10 Reactor Vessel Water Level to accur-ately reflect the design of the HPCS system Revise Isolation (2) Actuation Instru-L (08/09/83)
N/A Issued in Amendment 9 mentation to more accurately describe L (08/29/831 the signals that operate valve groups; Primary Containment to exempt primary containraent isolation valves which are locked closed in the steam tunnel; Containment and Drywell Isolation Valves to require that corresponding containment and drywell isolation valves be operable
Sheet 13 of f
GRAND GULF - I TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 ri III. Category (3) Conformance to as-built plant Source (a)
Priority (b)
Status Description Revise Containment and Drywell Isolation L (08/09/83) 1 under review by NRR Valves and Secondary Containment l-Ventilation System hutomatic Isolation Dampers / Valves to correct the isolation times of various valves 4
Revise SGTS and Control Room Emergency L (08/09/83)
N/A Issued in Amendment 9 Filtration System to clarify the requirements by exempting a portion of the ANSI N510-1975 r
Provide a.0.4 exemption for flain Steam L (08/29/83)
N/A Issued in Amendment 9 i
Line Isolation Valves Provide 3.0.3 and 3.0.4 exemption for L (09/09/83) 3 Under review by NRR Embankment Stability to permit opera-tional flexibility Revise Idle Recirculation loop Startup L (09/09/83) 3 under review by NRR to make this applicable only when the vessel pressure is creater than 25 psig j
.oy.%
am.,.,,
s
Sheet 14 of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License,-June 16, 1982 III. Category (3) Conformance to as-built plant Description Source ")
Priority (b)
Status I
Peeise ECCS Response Times to correct' L (09/09/83) 1 Under review by NRR the response tiems of the LPCI pumps
. Revise Reactor Coolant System Pressure L (09/09/83) 1 Under review by NRR Isolation Valves to clarify the valve numbers for RHR system valves and to Reactor Coolant System Interface Valves Leakage Pressure to remove the reference to RCIC Revise Control Rod Block Instrumentation L (09/09/83) 3 Under review by NRR to provide a 3.0.4 exception Revise Radioactive Gaseous Effluent L (09/09/83) 1 Under review by NRR Fonitoring Instrumentation to delete the requirement to perform Channel Functional Tests on the flow rate monitors Revise ECCS Actuation Instrumentation L (09/09/83) 1 Under review by NRR and PCIC System Actuation Instrumenta-tion to correct allowable value for the Suppression Pool Level-High Trip Function
Shest-15 of
+
GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982
- III. Category (3) Conformance to as-built plant Source (a)
Priority (h)
Status Description Revise Drywell Internal Pressure to L (09/09/83) 1 Under review'by NRR correct both the low end of the rance of differential pressures and the maximum external differential pressure Revise Fire Hose Stations to add two L (09/09/83) 1 Under review by NRR fire hose station Pevise Safety Related Mechanical L (09/09/83) 1 Under review by NRR snubbers to make necessary additions and deletions Revise RCIC Actuation Instrumentation L (09/09/83) 1 Under review by NRR to increase the number of channels required cperable for actuation of the system Changes isolation time for secondary L (Before C0A)
N/A Issued in Amendment I containment isolation valve Changes isolation time for drywell L (Refore C0A)
N/A Issued in Amendment 3 isolation valve
s Sheet 16 of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 fil. Category (3) Conformance to as-built plant Description Source (a)
Priorit.v(b)
Status Changes time for containment spray set-L (Before COA)
N/A Issued in Amendment 3 point i
Changes response time for type NZM L (Before COA)
N/A Issued in Amendment 3 circuit breakers Removes position indication and grants L (Before C0A)
N/A Issued in Amendment 4 surveillance procedure for Drywell t
Vacuum Breakers I
Changes response time for fuses associ-L (Before C0A)
N/A Issued in Amendnent 4 l
ated with Type N7M circuit breakers CTMT and Drywell Pressure NRC (02/09/84) 3 Under consideration by Licensee Recirculation Pump Trip ATWS NRC (02/09/84) 3 Under consideration by Licensee SRVs NRC (0?/09/84) 1 Under consideration by Licensee f
i
Sheet 17 of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 III. Category (3) Ccnformance to as-built plant Description Source (a)
Priority (b)
Status RCS Leakage NRC (02/09/84) 3 Under consideration by Licensee CTMT/Drywell Isolation Valves NRC (02/09/84) 1 Under consideration by Licensee l
Operational Conditions NRC (02/09/84) 3 Under consideration by Licensee CTMT Spray NRC.(02/09/84) 3 Under consideration by Licensee l
Isolation Instrumentation (2)
NRC (02/09/84) 3 Under consideration by Licensee j
Radiation Monitoring NRC (02/09/84) 3 Under consideration by Licensee i
Seismic Monitorino NRC (02/09/84) 3 Under consideration by Licensee LOP Division 3 NRC (02/09/84) 3 Under consideration by Licensee RCS Interface Valves NRC (02/09/84) 3 Under consideration by Licensee
s Sheet 18 of GRAND GULF - 1 TECHNICAL SPECIFICATION CHANGES Since Issuance of Low Power License, June 16, 1982 III. Category (3) Conformance to as-built plant I
a)
Priority (b)
Status Description Source Gaseous Effluent Vonitoring NRC (02/09/84) 3 Under consideration by Licensee ECCS - Operation (2)
NRC (02/09/84) 2 Under consideration by Licensee ECCS - Shutdown NRC (02/09/84) 2 Under consideration by Licensee RCIC Actuation Instrumentation NRC (02/09/84) 3 Under consideratton by Licensee Contair. ment and Drywell Isolation Valves NRC (02/09/84) 2 Under consideration by Licensee Snubbers NRC (02/09/84) 3 Under consideration by Licensee Rod Pattern Control System NRC (07/09/8a) 1 Under consideration by Licensee Instrument Air Supply NRC (02/09/84) 1 Under consideration by Licensee ADS Valves NRC (02/09/84)
?
Under consideration by Licensee
Shiet-i19 of-E GRAND GULF - 1 TECHNICAL SPECIFICATION: CHANGES j'
Since Issuance of Low Power License, June 16, 1982 III. Category (3) Conformance to as-built plant' Description-Source (a)
Priority (b)
Status l
TIP System Mapping NRC (02/09/84) 3 Under consideration by Licensee Control Rod Block Instruentation NRC'(02/09/84) 3 Under consideration by Licensee Suppression Pool Cooling NPC (02/09/84) 2 Under consideration by Licensee Isolation Actuation Instrumentation NRC (02/09/84) 2 Under consideration by Licensee Main Steam Line Flow-High Setpoint EG&G (03/8a) 1 Under consideration by Licensee Suppression Pool Level Indications (5)
RII (03/09/84) 1 Under consideration by Licensee Suppression Pool Temperature Instrumen-RII (09/09/84) 1 Under consideration by. Licensee tation Containment Spray Heat Exchanger RII (03/09/84) 1 Under consideration by Licensee Battery Charger Surveillances RII (03/09/84) 3 Under consideration by Licensee-L_
.i s
Sheet 20- of GRAND GULF - 1 TECHNICAL SPECIFICATI0N' CHANGES
~<
Since Issuance of Low Power License, June 16,.1982-III. Category (3) Conformance to-as-built plant Description Source (a)
Priority (b)
Status RPS-EPA Systems RII (03/09/84) 1 Under consideration by Licensee-ADS _ Operability RII (03/09/84-1 Under consideration by Licensee HPCS-LPCS Pump Flow RII (03/09/84) 1 Under consideration.by Licensee Leak Test of Hatch Seals RII (03/09/84).
1 Under consideration by Licensee r
i e
4
s SheQt-1 of.
GRAND GULF - 1 TECHNICAL SPECIFICATION. CHANGES Since Issuance of Low Power License, June 16, 1982 t
IV. Category (4) Change to:the b'ases section s
I
^
Source *)
Priority (b)
Status Description Correct reference in Bases for-TS 3.0.3 L (03/24/83)
N/A Issued in Amendment 7 CorrectMSIVTripSeti;ointinBases L (03/74/83)
N/A Issued in Amendment 7 Figure Correct Allowable Value for Reactor L (03/24/83)
N/A Issued in Amendment 7 Water Levels Lo-lo Delete incorrect isolation group closure L (03/24/83)
N/A Issued in Amendment 8 Delete erroneous paraoraph for Control L (03/?4/83)
N/A Issued in Amendment 7 Room Emergency Filtration System Correct references to TS in Bases L (04/07/83)
N/A Issued in Amendment 7 Section Delete paragraph in all the instrumenta-L (04/25/83)
N/A Issued in Amendment 7 tion Bases sections which addresses allowable values and instrument drifts
4 Shret 2
of.
~
GRAND GULF.- 1 TECHNICAL SPECIFICATION CHANGES Since issuance of Low Power License, June 16, 1982-1; IV. ' Category (4) Change to'the bases section Description Source (a)
- Priori ty(b)
Status-t' Revise Containment Internal Pressure L (09/09/83) 3 Under review by NRR to correct range limit for the. initial
' containment-to-Auxiliary.and Enclosure Building differential pressure 4
Embankment Stability NRC (02/09/84).
3 Under consideration by Licensee
{
i
?
I l
9 4
e 1
i l
- ~ -...
a Occket No. 50-416 March 20, 1984 LICENSEE:
Mississippi Power & Light FACILITY:
Grand Gulf Unit 1
SUBJECT:
SUMMARY
OF MARCH 14, 1984, MEETING REGARDING GRAND GULF UNIT 1 TECHNICAL SPECIFICATION REVIEW The meeting was held to review the current status of processing Technical Speci-fication changes, to obtain additional information on licensee's potential technical specification change ree.uests and to give the licensee NPC staff comr:ents resulting from its review of submitted requests for technical specifi-cation changes. Enclosure 1 is a list of attendees.
The licensee reviewed and discussed additional information regarding the potential technical specification changes (Enclosure ?i.
This information includes the licensee's definition of priorities and the estimated number of potential changes assigned to each priority. They currently estimate there are 32 out of the total of 240 potential changes that should be made prior to exceeding 5% power.
The licensee presented and discussed information regarding these 32 items (Attachment 4, Enclosure 2). The licensee also discussed some of the remainder of the 240 problem areas (Attachment 3, Enclosure 2).
The NRC staff discussed its status of review of Technical Specifications which have been submitted.
Information discussed and provided to licensee for its consideration are provided in Enclosure 3.
Of the 36 requested chances still pending 5 appear to be satisfactory, 2 have been evaluated and accepted by NRC technical review branches and for 3 others, additional information is needed by NRC staff.
/S/
L. L. Kintner, Project Manager Licensing Branch No. 1 Division of Licensing
Enclosures:
1.
List of Attendees 2.
Information Received from Licensee - Priority of potential Technical Specifi-cation changes - Sources of potential Technical Specifi-cation changes g),rJY Ob I
yw
-?-
Enclosures (Con't): - Technical Speci-fication problem sheets for 240 potential changes - Backup infonna-tion for 32 high priority potential changes - January 10, 1983, letter from licensee to J. P. O'Reilly (NRC) and January 13, 1983, letter from R. C. Lewis (NRC) to licensee regarding interpretation of Technical Specifications 3/4 3.6 (Source Range Monitors) 3.
Information provided to Licensee - Exerpt from 10/28/83 NRC memo from R. W. Houston to T. Novak providing evaluation of a change request submitted 10/11/83 regarding RCIC initiation - NRC memo dated Nov. 7, 1983, from V. Benaroya to C. O. Thomas providing evaluation of Items 1 and 23 submitted 9/9/83 regarding fire protection instruments, and fire hose stations - February 9, 1984, memorandum from R. C. Lewis (RII) to D. G. Eisenhut (NRR) regarding coments on NRC staff's second proof and review in the fall of 1983 Attachment a - NRC Inspection Peport 50-416/84-06 regarding Technical Specification discrepancies - NRC staff comments and recommended changes for Item 29 of the 9/9/83 submittal reouesting a change in Tech-nical Specification nomencla-ture for radioactive effluent specifications
. Enclosures (Con't): - NRC recommended low priority changes for
,~
radioactive effluent tech-nical specifications I
cc: See.next page t
A 4-1 J(
j
(..~
DL:LB #1 DltDB#4 LKintner/hmc EAdensam 3/
84 3/i.'/84
GRAND GULF Mr. J. P. McGaughy Vice President Nuclear Production Mississippi Power & Light Company P.O. Box 1640 Jackson, Mississippi 39205 cc:
Robert B. McGehee, Esquire Wise, Carter, Child, Steen and Caraway P.O. Box 651 Jackson, Mississippi 39205 Troy B. Conner, Jr., Esquire Conner and Wetterhahn 1747 Pennsylvania Avenue, N.W.
Washington, D. C.
20006 Mr. Ralph T. Lally Manager of Ouality Middle South Energy, Inc.
225 Baronne Street P.O. Box 61000 New Orleans, Louisiana 70161 Mr. Larry Dale Mississippi Power & Light Company P.O. Box 1640 Jackson, Mississippi 39205 Mr. R. W. Jackson, Project Engineer Grand Gulf Nuclear Station Pechtel Power Corporation Gaithersburg, Maryland 20760 Mr. Alan G. Wagner Senior Resident Inspector Route 2, Box 399 Port Gibson, Mississippi 39150 James P. O'Reilly, Regional Administrator U.S. Nuclear Regulatory Commission, Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303
=
List of Attendees MP&L - NRC 3/14/84 Meeting MPAL J. P. McGaughy L. F. Dale S. H. Hobbs J. H. Starling J. C. Roberts NRC L. L. Kintner D. S. Brinkman Cecil 0. Thomas Donald R. Hoffman E. Adensam W. W. Meinke M. Virgilio J. Lee
Enclosure ?
Information Received from Licensee - Priority of potential Technical Specification changes - Sources of potential Technical Specification changes - Technical Specification problem sheets for 240 potential changes - Packup information for 32 high priority potential changes - January 10, 1983, letter from licensee to J. P. O'Reilly (NRC) and January 13, 1983, letter from R. C. Lewis (NRC) to licensee regarding interpretation of Technical Soecifi-cations 3/4 3.6 (Source Range Monitors)
4 Information provided to Licensee - Exerpt from 10/28/83 NRC memo from R. W. Houston to T. Novak providing evaluation of a change request submitted 10/11/83 regarding RCIC initiation
' - NRC memo dated Nov. 7, 1983, from V. Benaroya to C. O. Thomas providing evaluation of Items 1 and 23 submitted 9/9/83 regarding fire protection instruments, and fire hose stations - February 9, 1984, memorandum from R. C. Lewis (RII) to D. G. Eisenhut (NRR) regarding comments on NRC staff's second proof and review in the fall of 1983 - NRC Inspection Report 50-416/84-06 reoarding Technical Specifi-cation discripancies - NRC staff comments and recommended changes for Item 29 of the 9/9/83 submittal requesting a change in Technical Specifica-tion nomenclature for radioactive effluent specifications - NRC recommended low priority changes for radioactive effluent technical specifications i
s l
l l
O March 20, 1984 MEETING
SUMMARY
DISTRIBUTION Docket No: 50-416 l ~2 NRC PDR I
Local PDR NSIC PRC System LB #4 r/f Attorney, OELD
'l$2.!Adensam'.~. j Project Manager L. L. Kintner Licensing Assistant M. Duncan Donald Hoffman Candle Julian, RII NRC PARTICIPANTS L. L.Kintner D. S. Brinkman Cecil 0. Thomas Donald R. Hoffman E. Adensam W. W. Meinke M. Virgilio J. Lee bec:
Applicant & Service List
,p')
/
Y
)s
/
, ' L '.' "
/
')
/,
.,/ Qf[
/
/f