0 JAN 15 T.;
MEMORANDUM FOR:
James E. Gagliardo, Director Division of Resident, Reactor Project and Engineering Programs, RIV 4
FROM:
Edward L. Jordan Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement
SUBJECT:
CRACKED WELDS AND LOOSE PARTS IN COMBUST!0h ENGINEERING (CE) STEAM GENERATORS
REFERENCE:
Memorandum from T. W. Bishop dated September 13, 1983.
Please consider the issues raised in the enclosed memorandum in your inspection of the Waterford Units.
Edward L. Jordan Director Division of Emergency Preparedness and Engineering Response, IE
Enclosure:
Veno E. L. Jordan to T. W. Bishop dated M: 1 3 1984 J
cc:
C. Rossi, IE DISTRIBUTION R. W. Starostecki, RI A5 R. C. Lewis, RI!
DEPER R/F C. E. Morelius, R111 EGCB R/F R. L. Bangart, RIV MSWegner R/F T. W. Bishop, RV SASchwartz J. M. Taylor. IE RLBaer J. G. Partlow, IE WLFisher E. B. Blackwood, ED0 MSWegner I
CONTACT:
M. W. Wegner, IE I
49-24511 Fo/4 - 8+-W3 l
S$ 5+
/
tv#.M DEPER:
DEPER:IE DEPER:!E DD:DEPER: IE D
- !E lA. Fisher RLlaer J
SASchwartz E o dar l
1/6/
_ 1/6 /84 _ 1/g /84 1/ /84 1/&/84
- E oIE8Ea %
=
=
i
/
\\
, NUCLEAR REGULATORY COMMISSION UNITED STATES wASMeseSToes. D. C.seems JAN 1 3 1984 i
MEMORANC.?! FOR:
Thomas W. Bishop. Director Division of Resident Reactor Project and Engineering Programs, RV TROM:
Edward L. Jordan. Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement i
SUBJECT:
CRACKED WELDS AND LOOSE PARTS IN COMBUSTION ENGINEERING (CE) STEAM GENERATORS l
REFERENCE:
Memorandum from T. W. Bishop dated September 13, 1983 l
The issue of loose parts in steam generators was addressed in IN 83-24. We see l
nothing basic to change or amend in the IN at this time.
Although Westinghouse was the annufacturer of the steam generators referenced in the IN, no manu-facturer was specifically mentioned and the IN is applicable to all steam generators.
l We feel that the matter of cracked welds for any steam generators manufactured in the future by CE could best be handled by the Vendor Program Branch.
Manufacturing defects of this type should have been caught by.the, vendors QC program.
By separate meno, we are requesting that the Vendor Program Branch include this item in their next scheduled inspection of the CE steam generator fabrication facility. This should reduce or eliminate the problem in any steam generators fabricated by CE either for replacement of existing equipment or for plants which any be ordered.in the future.
The regional offices should assure the inspection of any CE steam generators that have been fabricated and are now at the site of facilities not yet' operating. The enclosure to the referenced memo indicates that the licensee performed a thorough inspection of the WPPS 3 steam generators, but the extent of the inspections performed at Palo Verde is not' clear. We recommend that i
RV assure that the steam genersters at Palo Verde are inspected prior to
)
start-up, if tais has not alres% been accomplished. By separate meno, we i
are recs h ing the_sa_m_e action to RIV regarding the Waterford units.
7
\\
1 M.!. Wegner. E
'5 gg/-
CONTACT:
49-24511 g
l i
=
4 Jht,1
d-2-
l Thomas W. Bishop Further action by IE on this matter will depend upon the results of the findings by the Vendor Program Branch and the regional offices.
p Edwa rd Jordan, Director Divisio of Emergency Preparedness and 1 ineering Response, IE cc:
C. Rossi, IE R. W. Starostecki, RI R. C. Lewis, RI!
C. E. Morelius, RI!!
J. E. Gagliardo, RIV R. L. Bangart, RIV U. Potapovs. RIV J. G. Partlow, IE J. M. Taylor, IE E. B. Blackwood, EDO 9
l l
l
-,N-.-.-,--,---.,
n,,--e_.__
-n,.,.,-,,___
~. - - -
-