_____ _ _ _ _ _ _ _ _ _ _ _

ll I

Duke P6uerCompany T C Mcsktxn McGuire Nuclear Generation Depamnent lice President 12700Hagers ferry Road (MG01\\P)

(704)8754800 Hunters'ylle.NC 80784985 (704)8754809 Fax DUKEPOWER March 31, 1995 U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

McGuire Nuclear Station Unit 2 Docket No. 50-370 4

Section XI, Inservice Inspection Reexamination of Reactor Vessel Planar Flaw Final Report

Dear Sir:

Please find enclosed the final report involving the Unit 2 Flaw #213 Characterization Project.

l Flaw # 213, located in weld 01, has been reclassified based on recent near surface data from an unacceptable surface connected planar flaw to an acceptable subsurface volumetric flaws an acceptable subsurface volumetric flaw, no further periodic inspections are required.

Weld 01 will be examined during the 20 year ISI inspection.

This inspection is expected to occur during refueling outage 2EOC-14.

By issue of this final report, Duke Power Company considers the matter of flaw 213 to have reached final resolution.

We will inform the staff should unforeseen circumstance involving Flaw #213 arise.

This report is submitted for NRC information.

Should yoti need additional information or if questions arise, please contact John M. Washam at (704) 875-4181.

Very truly yo rs, P?at

.C.

McMeekin 4060090 950331 Q

ADDCK 05000370.,

PDR

\\x i\\

na,.a.e,,,

{

q

.U 'S. Nuclear Regulatory Commission March 31, 1995 page 2 xc.(without attachment)

Mr. S.D. Ebneter Regional Administrator, Region II U.S. Nuclear Regulatory Commission g

101 Marietta Street, NW, Suite 2900 Atlanta, Georgia

.30323

)

Mr. George F. Maxwell Senior NRC. Resident Inspector, McGuire McGuire Nuclear Station Mr. Victor Nerses, Project Manager l

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 9H3 Washington, DC 20555 l

i xc.(with attachment)

Mr. Nick Ecnomos i

Region II j

U.S. Nuclear Regulatory Commission 101 Marietta Street, 24, Suite 2900 2

Atlanta, Georgia 30323 i

l.

i l

I i

l l

c I

)

t l

}

- + -

m-e-

-,-,,,,,,m e,.-..,,, ---

-w.,,,.,,

  • ,,r,,.

.