AECM-83-0561, Part 21 Rept 2 Re Improperly Assembled Automatic Switch Co Spare Part Kits for Scram Pilot Valve Solenoids.Initially Reported on 830804.Investigation Continuing.Final Rept Will Be Provided by 840224

From kanterella
(Redirected from ML20080F299)
Jump to navigation Jump to search
Part 21 Rept 2 Re Improperly Assembled Automatic Switch Co Spare Part Kits for Scram Pilot Valve Solenoids.Initially Reported on 830804.Investigation Continuing.Final Rept Will Be Provided by 840224
ML20080F299
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 09/09/1983
From: Mcgaughy J
MISSISSIPPI POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-83 AECM-83-0561, AECM-83-561, AECM-8310561, NUDOCS 8309190256
Download: ML20080F299 (2)


Text

. e

. >a A [(j ,*II?,9 MISSISSIPPI POWER & LIGHT COMPANY.

Helping Build Mississippi < L. .l P. O. B O X 16 4 0, J A C K S O N , M I S S fS!kTjP 39205 E Ag.

JAMES P. McGAUGHY, JR. '

..c m ...m Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.

Suite 2900 Atlanta, Georgia 30303 Attention: Mr. J. P. O'Reilly , Regional Administrator

Dear Mr. O'Reilly:

SUBJECT:

Grand Gulf Nuclear Station Unit 1 Docket No. 50-416 License No. NPF-13 File 0260/15525/15526/16694.4 PRD-83/10, Interim Report No.

2, ASC0 Spare Parts Kits for Scram Pilot Valve Solenoids AECM-83/0561

Reference:

AECM-83/0445 On August 4,1983, Mississippi Power & Light Company notified Mr. Paul Fredrickson, of your office, of a Reportable Deficiency at the Grand Gulf Nuclear Station (GGNS). The deficiency concerns the receipt of improperly assembled ASCO spare parts kits for the scram pilot valve solenoids.

As previously reported, MP&L has evaluated and determined this deficiency to be reportable under the provisions of 10CFR21 for Unit 1. MP&L has no additional information to of fer at this time. The investigation is continuing to determine whether this deficiency is applicable to Unit 2.

We expect to submit our Final Report by February 24, 1984.

Yours truly,

/

p J. P. McGaughy, Jr.

ACP:dr .

cc: See page 2 0309190256 830909 PDR ADOCK 05000 g. ,

S '

Member Middle South Utilities System 8

. .a Mr. - J. P. O'Reilly AECM-83/0561 NRC Page 2 cc: Mr. J. B. Richard Mr. R. B. McGehee Mr. T. B. Conner Mr. Richard C. DeYoung, Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. C. B. Taylor South Miss. Electric Power Association P. O. Box 1589 Hattiesburg, MS 39401-i

- , , . . . - - . , __ ,_ . _ _ . _ . , _ _ _ _ _ . _ _ , . _ _ _ _ . _ _ . _ .