ML20070J793

From kanterella
Jump to navigation Jump to search
Forwards Rev 8 to Oyster Creek Nuclear Generating Station Pump & Valve Inservice Testing Program
ML20070J793
Person / Time
Site: Oyster Creek
Issue date: 07/15/1994
From: J. J. Barton
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20070J794 List:
References
C321-94-2113, NUDOCS 9407250318
Download: ML20070J793 (2)


Text

GPU Nuclear Corporation Nuclear

=.it:388 Forked River. New Jersey 08731-0388 609 971 4000 Wntor's Direct Dial Number:

July 15,1994 C321-94-2113 U. S. Nuclear Regulatory Commission Att: Document Control Desk Washington, DC 20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Inservice Test Program; Revision 8 l

By letter dated October 11,1991, GPU Nuclear submitted Revision 7 to the Inservice l Test Program for the Oyster Creek Nuclear Generating Station. The USNRC responded by Safety Evaluation dated September 22,1992, which requested additional

, information to be provided. GPU Nuclear provided nearly all of the requested information by letter dated December 22,1992. The USNRC then issued a second Safety Evaluation on August 24,1993. The enclosure to this letter provides the  ;

information which was not included in the December 22,1992 GPU Nuclear submittal and dockets Revision 8 to the Inservice Test Program. This closes all outstanding items previously identified by the USNRC.

A list of changes for Revision 8 has been provided on pages 2 and 3 of the enclosure to this letter to assist in the review of the program. This list includes the following two  !

NRC items:

NRC Item 7 (GPUN Relief Request 29)

Control Rod Hydraulic Control Unit rupture disks The rupture disks have been removed from the program as they are not within the ASME code class boundary as per the guidance in Regulatory Guide 1.26 " Quality Group Classifications and Standards for Water, Steam, i and Radioactive Waste Containing Components of Nuclear Power Plants",

and do not perform any safety related function. ,

e. I c 94o7250318 940715 g* PDR ADOCK 05000219 i P PDR l- >/

GPU Nuclear Corporation is a subsidiary of General Pubhc Utihties Corporation > (}

C321-94-2113 Page 2

~

NRC Item 13 (GPUN Relief Request 40)

Hydrogen / Oxygen Monitoring system valves As per the guidance in Regulatory Guide 1.26 " Quality Group Classifications and Standards for Water, Steam, and Radioactive Waste ,

Containing Components of Nuclear Power Plants", the specified valves in the Hydrogen / Oxygen Monitoring sytem are not within the ASME code class boundary. However, they have remained within the IST Program as Non-Code Class components, therefore, reliefis not required.

If any additional information or assistance is required, please contact Mr. John Rogers of my staff at 609.971.4893.

( , I

. ~

i (

Join J. BaQon ice President and Director Oyster Creek JJB/JJR Enclosure cc: Oyster Creek NRC Project Manager Administrator, Region I Senior Resident inspector l

r -

, - - 3,,n . -,i,_ 1e w-, . .n w--