MONTHYEARML17313B0991999-10-14014 October 1999 Forwards LER 99-005-00 Reporting Findings & Corrective Actions Taken as Result of Out of Tolerance MSSV Condition in Unit 1 Which Was Discovered During pre-outage Testing ML17313B0881999-10-12012 October 1999 Forwards Response to NRC 990831 RAI Re Several Relief Requests That Accompanied Second ten-yr Interval ISI Program Submitted on 980317.Revised Relief Request 6 Is Provided in Encl 2 ML17300B3501999-09-29029 September 1999 Forwards Revised Bases Pages,Providing Addl Discussion of Options Available to Exit Required Action G of TS 3.8.1 & Revised Page for TS 3.3.7,in Response to NRC RAI Re Proposed Amend to TS 3.8.1 & 3.3.7 ML17300B3551999-09-28028 September 1999 Responds to Aministrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams. Proposed Palo Verde Operator Licensing Exam Schedule & Estimated Number of Applicants Planning to Take Exams Encl ML17313B0851999-09-24024 September 1999 Requests Approval of Alternative to Repair Requirements of 10CFR50.55a,authorizing Alternative Use of Mechanical Nozzle Seal Assemblies,As Described in Encl,For RCS Hot Leg Instrumentation & Sampling Nozzles for Two Operating Cycles ML17313B0781999-09-20020 September 1999 Forwards Rev 22 to PVNGS Emergency Plan. Summary Description of Changes,Included ML17300B3331999-09-14014 September 1999 Forwards MOR for August 1999 & Revised MOR for Jul 1999 for Pvngs,Units 1,2 & 3 ML17300B3351999-09-0808 September 1999 Informs That Repairs to Plant EDG 2A Jacket Water Cooling sub-sys Were Completed & EDG Was Declared Operable on 990903 at Approx 21:45 Mst.Noed Was Not Necessary,Since 72 Hour Completion Time Was Met ML17313B0761999-09-0303 September 1999 Requests Enforcement Discretion to TS Section 3.8.1, AC Sources - Operating. Enforcement Discretion Would Allow,On One Time Basis,Extension of Completion Time in Required Action B.4 of TS 3.8.2 from 72 H to 108 H ML17313B0731999-08-31031 August 1999 Informs That RR Bean (License OP-50452-1) Has Been Permanently Reassigned to Position That Does Not Require License & Requests That Individuals License Be Expired Per 10CFR55.55 ML20211A9501999-08-12012 August 1999 Discusses 990720-21 Workshop Conducted in Region IV Ofc,Re Exchange of Info in Area of Use of Risk Insights in Regulatory Activities.List of Attendees,Summary of Topic & Issues,Agenda & Copies of Handouts Encl ML17313B0581999-08-0606 August 1999 Forwards Rev 1 of Changes to TS Bases Implemented Between Aug 1998 & Jul 1999.Insertion Instructions & List of Affected Pages Included ML17313B0311999-08-0303 August 1999 Submits Response to NRC AL 99-02, Operating Reactor Licensing Actions Estimates, for Fys 2000 & 2001 ML20210L1461999-08-0303 August 1999 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam on 991006.Requests Submittal of Ltr Identifying Individuals Taking Exam,Personnel Allowed Access to Exams & Mailing Address for Exams ML17313B0431999-07-30030 July 1999 Advises of Listed Senior Mgt Changes That Have Taken Place at Plant ML17313B0441999-07-30030 July 1999 Forwards Comments on Draft NRC Repts Evaluation of AOVs at Us Light-Water Reactors (1999) & Idaho Natl Engineering & Environ Lab Rept (INEEL)EXT-98-00383,Study of AOVs in Npps. ML17313B0151999-07-20020 July 1999 Submits Request to Obtain All Data Previously Sent by PVNGS & Currently in REIRS for OLs NPF-41,NPF-51 & NPF-74.Data Is Requested in Electronic Form (Ascii Format) as It Currently Exists in REIRS Sys ML17313B0091999-07-20020 July 1999 Forwards Requested Calculations Performed to Verify That Increase in Max Radially Averaged Enrichment for Fuel Assemblies from 4.3 Weight Percent to 4.8 Weight Percent Did Not Affect Requirements for TSs 3.7.15,3.7.17 & 4.3.1 ML17313B0171999-07-16016 July 1999 Forwards LER 99-005-00,re Automatic Rt Which Occurred on 990618,following Sensor Failure in Core Protection Calculators.Corrective Actions Described in LER Are Not Necessary to Maintain Compliance with Regulations ML17300B3111999-07-15015 July 1999 Forwards PVNGS Unit 2 ISI Rept for Eighth Refueling Outage. No Commitments Made to NRC by Ltr ML17300B3141999-07-15015 July 1999 Forwards Corrected Electronic Files for Individual Monitoring Repts for 1998.Original Electronic Files Were Found to Have Two Administrative Errors,Which Has Been Corrected.Encl Withheld,Per 10CFR2.790 ML20209G6771999-07-0808 July 1999 Forwards Supplemental Info to Confirm That Decommissioning Funding Plans of Public Service Co of Nm for Interests in PVNGS Have Been Reviewed by Nm Public Regulation Commission. Final Order & Recommended Decisions in Case 2742,also Encl ML17300B2931999-07-0202 July 1999 Submits Withdrawal of Relief 5 for Second ISI Interval for Units 1,2 & 3.Proposed Alternative Is Related to Exam Requirements for Component Supports for Second ISI Interval ML17313A9951999-06-26026 June 1999 Provides Response to NRC GL 98-01,Suppl 1, Y2K Readiness of Computer Sys at Nuclear Power Plants. ML17300B2831999-06-26026 June 1999 Requests NRC Approval of Proposed Alternative IAW Provisions of 10CFR50.55a(a)(3)(i) to 10CFR50.55a(g) & Requirements of ASME Boiler & Pressure Vessel Code Section XI for Repairs & Installation.Description of Proposed Alternative,Encl ML17313A9901999-06-15015 June 1999 Forwards Response to RAI Re GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Movs. No Commitments Being Made to NRC by Ltr ML17313A9521999-05-24024 May 1999 Notifies NRC That Ja Proctor,License SOP-50314,has Been Permanently Reassigned to Position That Does Not Require License.License Should Be Expired,Per 10CFR55.55 ML20206Q3111999-05-18018 May 1999 Final Response to FOIA Request for Documents.Forwards App a Records Being Released in Entirety ML17313A9311999-05-13013 May 1999 Notifies NRC That Rev 2 to COLR for Unit 2 Remains Applicable Following Recently Completed Unit 2 Reload ML17313A9481999-05-12012 May 1999 Informs of Change Needed in Order to Update Current Mailing List.Future Mailings for J Horne Should Be Forwarded to Listed Address ML17313A9261999-05-0707 May 1999 Forwards LER 99-004-00,per 10CFR50.73.LER Repts Findings & Corrective Actions Taken as Result of Unit 2 Out of Tolerance Pressurizer Safety Valve (Psv) Condition Which Was Discovered During Outage Testing ML20206H1931999-05-0303 May 1999 Forwards 1998 Annual Rept, for SONGS Units 2 & 3 & PVNGS Units 1,2 & 3.SCEs Form 10K Annual Rept to Securites & Exchange Commission for Fiscal Yr Ending 981231,encl ML17313A9091999-04-30030 April 1999 Forwards Proprietary Proposed Test Outlines for Initial License Exams to Be Administered at PVNGS in Aug/Sept 1999. No Commitments Are Contained in Ltr.Proprietary Info Withheld ML17313A9181999-04-30030 April 1999 Forwards Electronic File of Individual Monitoring Repts for 1998.Encl Withheld Per 10CFR2.790 ML17313A9191999-04-30030 April 1999 Forwards Special Rept 2-SR-99-001 Re SG Tube Plugging in PVNGS Unit 2,per TS Reporting Requirement 5.6.8.Complete Results of SG Tube Inservice Insp Will Be Submitted by 000422 ML17300B3751999-04-23023 April 1999 Forwards LER 99-003-00,reporting Condition Prohibited by TS 3.7.17 Where Spent Fuel Assembly Was Stored in Inappropriate Region in Spent Fuel Pool ML17313A9081999-04-23023 April 1999 Documents 990421 Telcon with E Emeigh,Which Requested Extension for Submitting Next Matl Balance Rept for Pvngs,As Required by 10CFR70.53 & 74.13.Required Info Will Be Submitted by 990531 ML20205T7421999-04-21021 April 1999 Forwards Partially Withheld Insp Repts 50-528/99-05, 50-529/99-05 & 50-530/99-05 on 990322-26.Determined That Security Program Properly Implemented.Insp Repts Details Withheld (Ref 10CFR73.21) ML17313B0271999-04-21021 April 1999 Forwards Proprietary Epec Pro Forma Cashflow Statement for 1999.Proprietary Info Withheld,Per 10CFR2.790.Affidavit Encl ML17313A9031999-04-21021 April 1999 Forwards Rev to Relief Request 12 Submitted 990420 to Second 10-yr ISI Interval.Revised Relief Request Discusses in More Detail Actions APS Will Take When There Is Identified Leakage from Bolted Connection ML17313A8971999-04-20020 April 1999 Requests Use of Alternatives to 10CFR50.55a(g) Inservice Insp Requirements.Proposed Alternatives Are Related to Visual Exam of Bolted Connections 05000529/LER-1999-002, Forwards LER 99-002-00 Re Findings & Corrective Actions Taken as Result of Plant Out of Tolerance MSSV Condition Which Was Discovered During pre-outage Testing1999-04-19019 April 1999 Forwards LER 99-002-00 Re Findings & Corrective Actions Taken as Result of Plant Out of Tolerance MSSV Condition Which Was Discovered During pre-outage Testing ML17313A8931999-04-14014 April 1999 Forwards LER 99-003,reporting Condition Prohibited by TSs That Existed When Surveillance Requirement to Verify Essential Chilled Water Sys Valve Positions Was Not Met ML20205Q0821999-04-13013 April 1999 Forwards Second ISI Interval Relief Request 10 from ASME Section XI & Applicable Addenda Re Visual Exams Performed Subsequent to Repair or Replacement of Component or Alteration of Item ML17313A8901999-04-13013 April 1999 Forwards LER 98-003-01 Re MSSV as-found Lift Pressures out- Side of TS Limits.Ler Suppl Provides Evaluation Findings from Unit 3 out-of-tolerance MSSVs Conditions Which Were Discovered During pre-outage Testing ML17313A8831999-04-0808 April 1999 Forwards 1998 Annual Radioactive Effluent Release Rept for Pvngs,Units 1,2 & 3 & Rev 13 to ODCM, for Pvngs,Units 1,2 & 3 IAW TS 5.6.3 ML20205F3491999-03-30030 March 1999 Forwards Proprietary & non-proprietary Info Re Status of Decommissioning Funding for Pvngs,Units 1,2 & 3,per 10CFR50.75(f)(1).Proprietary Info Withheld,Per Requirements of 10CFR2.790(b)(1) ML17313A8671999-03-24024 March 1999 Submits Info Re Present Levels & Sources of Property Insurance Maintained for Pvngs,Per 10CFR50.54(w)(3) ML17313A8601999-03-16016 March 1999 Forwards Revised Relief Requests PRR-05,PRR-06 & PRR-11 to Clarify That Proposed Design Flow Testing for Lpsi,Hpsi & Containment Spray Pumps Will Be Performed Using Instruments That Comply with Code Requirements,Per 990226 Telcon ML17313A8551999-03-0505 March 1999 Requests Proposed Code Alternative IAW 10CFR50.55a(e)(3),as Acceptable Alternative to Requirements of 10CFR50.55a(e)(1), for Installation of in-line safety-related Flow Measurement Instrument in ASME Class 3 Pipe 1999-09-08
[Table view] Category:OUTGOING CORRESPONDENCE
MONTHYEARML20211A9501999-08-12012 August 1999 Discusses 990720-21 Workshop Conducted in Region IV Ofc,Re Exchange of Info in Area of Use of Risk Insights in Regulatory Activities.List of Attendees,Summary of Topic & Issues,Agenda & Copies of Handouts Encl ML20210L1461999-08-0303 August 1999 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam on 991006.Requests Submittal of Ltr Identifying Individuals Taking Exam,Personnel Allowed Access to Exams & Mailing Address for Exams ML20206Q3111999-05-18018 May 1999 Final Response to FOIA Request for Documents.Forwards App a Records Being Released in Entirety ML20205T7421999-04-21021 April 1999 Forwards Partially Withheld Insp Repts 50-528/99-05, 50-529/99-05 & 50-530/99-05 on 990322-26.Determined That Security Program Properly Implemented.Insp Repts Details Withheld (Ref 10CFR73.21) ML17313A7751999-02-0505 February 1999 Discusses Proposed Changes to PVNGS Emergency Plan Submitted by Licensee on 980908.Rev Would Result in Two Less Radiation Protection Positions Immediately Available During Emergencies.Forwards SE Supporting Proposed Changes ML20202J4891999-02-0202 February 1999 First Final Response to FOIA Request for Records.Records in App a Available in PDR ML20196D6291998-11-20020 November 1998 Forwards Insp Repts 50-528/98-13,50-529/98-13 & 50-530/98-13 on 981019-24 & NOV Re Improper Changes to Physical Security Plan ML20151X2321998-09-0909 September 1998 Ack Receipt of & Check for $50,000 in Payment for Civil Penalty Proposed in NRC ML20236U9241998-07-28028 July 1998 Final Response to FOIA Request for Documents.Records Subj to Request Encl & Identified in App A.App B Records Being Withheld in Part (Ref FOIA Exemption 7) ML20236N0331998-07-10010 July 1998 Discusses Investigation Repts 4-97-022S & 4-98-014 on 980331 & Forwards NOV & Proposed Imposition of Civil Penalty in Amount of $50,000 ML20236N2291998-07-10010 July 1998 Discusses Investigation Repts 4-97-022S & 4-98-014 Completed on 980213,predecisional EC Conducted on 980331 & Forwards Notice of Violation Re Falsification of Surveillance Test Record at Plant IR 05000528/19980011998-02-0303 February 1998 Forwards Insp Repts 50-528/98-01,50-529/98-01 & 50-530/98-01 on 980112-16 & NOV Re Inadequate Protected Area Detection Aids.Portions of Licensee Physical Security Program Was Also Examined.Portions of Insp Repts Withheld,Per 10CFR73.21 ML20203E9011997-12-11011 December 1997 Responds to Requesting Fee Exemption Under Provision of 10CFR170.21,footnote 4,item 3 for NRC Review of NIST Natl Voluntary Lab Accreditation Program.Submittal Meets Criteria for Fee Waiver Provided in 10CFR170.21 ML20198L4511997-10-20020 October 1997 Forwards Partially Deleted Insp Repts 50-528/97-23, 50-529/97-23 & 50-530/97-23 (Ref 10CFR73.21) on 970922-26.No Violations Noted.Nrc Determined That Licensee Physical Security Program Effectively Implemented IA-97-232, Final Response to FOIA Request for Documents.Records in App a Encl & Available in PDR1997-07-23023 July 1997 Final Response to FOIA Request for Documents.Records in App a Encl & Available in PDR ML20149H8551997-07-23023 July 1997 Final Response to FOIA Request for Documents.Records in App a Encl & Will Be Available in Pdr.App B Records Being Made Available in PDR ML20196H4261997-07-23023 July 1997 Final Response to FOIA Request for Documents.Records in App a Encl & Available in PDR ML20149H8191997-07-14014 July 1997 Third Partial Response to FOIA Request for Documents. Documents Listed in App a Being Released in Entirety.Copies of Records 11-15 May Be Purchased from Government Printing Office IA-97-135, Final Response to FOIA Requests for Documents.Records in App a Encl & Will Be Available in PDR1997-04-29029 April 1997 Final Response to FOIA Requests for Documents.Records in App a Encl & Will Be Available in PDR ML20140F1961997-04-29029 April 1997 Final Response to FOIA Requests for Documents.Records in App a Encl & Will Be Available in PDR ML20138C0751997-04-22022 April 1997 Forwards Insp Repts 50-528/97-08 & 50-530/97-08 on 970317-21 & Nov.Two Violations Identified Involving Failure to Adequately Protect Safeguards Info & Maint Adequate Vehicle Barrier Sys ML20137R3801997-04-0909 April 1997 Forwards NRC Proposed change,TSB-011,to Administrative Controls Section of STS to Accommodate Changes to 10CFR20, 10CFR50.36A,10CFR50, & 10CFR55 ML20137K4711997-03-25025 March 1997 Nineteenth Partial Response to FOIA Request for Documents. Records Subj to Request Encl & Identified in App DD & Ee ML20135C4771997-02-20020 February 1997 Informs That Info Being Provided to Plant Security Manager That Could Assist in Efforts to Protect Plant Against Insider Requirement of design-basis Threat ML20140E1411997-01-31031 January 1997 Forwards Insp Repts 50-528/96-20,50-529/96-20 & 50-530/96-20 on 961007-11.No Violations Noted ML20133G1691997-01-0909 January 1997 Retracts Re Amends of 40 & 41 of Palo Verde Physical Security Plan NUREG-0908, Ack Receipt of 961030 Amend 41 to Physical Security Plan. Eleven Changes Did Not Meet Criteria of 10CFR50.54(p),two Changes Did Not Follow Acceptance Criteria of NUREG-0908 & 37 Changes Require Clarification1996-12-0909 December 1996 Ack Receipt of 961030 Amend 41 to Physical Security Plan. Eleven Changes Did Not Meet Criteria of 10CFR50.54(p),two Changes Did Not Follow Acceptance Criteria of NUREG-0908 & 37 Changes Require Clarification ML20129F3631996-10-23023 October 1996 Ack Receipt of Which Transmitted Rev 12 to Training Qualification Plan for Plant.Change Appears to Be Inconsistent W/Criteria of 10CFR50.54(p) & Being Referred to NRR ML20138F9061996-10-11011 October 1996 First Partial Response to FOIA Request for Documents.Records in App a Being Made Available in PDR IR 05000528/19960091996-08-21021 August 1996 Forwards Insp Repts 50-528/96-09,50-529/96-09 & 50-530/96-09 on 960715-19 W/Interoffice Review Continuing to 960820.No Violations Noted ML20059L5031994-01-28028 January 1994 Extends Invitation to Participate in Workshop Re Emergency Preparedness & Incident Response on 940222 in Arlington,Tx ML20059J8511994-01-19019 January 1994 Forwards Statement of Work for Task Order 2 Re Emergency Action Levels Reviews ML20059K6701994-01-13013 January 1994 Forwards Correction to Ltr Transmitting Insp Repts 50-528/93-48,50-529/93-48 & 50-530/93-48 to Correct Date of 930105 W/Correct date,940105 ML20059K6781994-01-0404 January 1994 Forwards Insp Rept 50-528/93-48,50-529/93-48 & 50-530/93-48 on 931102-1206 & Notice of Violation ML20059A1541993-12-16016 December 1993 Forwards Insp Repts 50-528/93-47,50-529/93-47 & 50-530/93-47 on 931108-10.No Violations Noted ML20059A3651993-12-16016 December 1993 Forwards Insp Repts 50-528/93-49,50-529/93-49 & 50-530/93-49 on 931115-19.No Violations Noted ML20059A3561993-12-13013 December 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp of Facility IR 05000528/19930401993-12-0909 December 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-528/93-40, 50-529/93-40 & 50-530/93-40 ML20058H4061993-12-0303 December 1993 Reissues Insp Repts 50-528/93-35,50-529/93-35 & 50-530/93-35 Due to Administrative Error When Previously Issued on 930916 ML20058H9151993-12-0303 December 1993 Forwards Insp Repts 50-528/93-35,50-529/93-35 & 50-530/93-35 on 930713-0816 & Notice of Violation.Expresses Concern Re Two Instances of Failure to Properly Document Surveillance Test Deficiencies ML20059A1761993-12-0202 December 1993 Forwards Meeting Repts 50-528/93-50,50-529/93-50 & 50-530/93-50 on 931115 IR 05000528/19930451993-11-26026 November 1993 Discusses Insp Repts 50-528/93-45,50-529/93-45 & 50-530/93-45 on 931025-29 & 1102-05.Violations Noted.Encl Withheld (Ref 10CFR73.21) ML20058H3751993-11-23023 November 1993 Forwards Insp Repts 50-528/93-43,50-529/93-43 & 50-530/93-43 on 930921-1101.No Violations Noted ML20058H2731993-11-19019 November 1993 Forwards Insp Repts 50-528/93-46,50-529/93-46 & 50-530/93-46 on 930913-1029.No Violations or Deviations Noted IR 05000528/19930351993-11-18018 November 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-528/93-35, 50-529/93-35 & 50-530/93-35 on 930916 ML20058H3151993-11-17017 November 1993 Forwards Insp Repts 50-528/93-32,50-529/93-32 & 50-530/93-32 on 931018-22.No Violations Noted ML20058A1181993-11-16016 November 1993 Forwards Safeguards Info Referenced in Preliminary Draft Guide Re Proposed Rule for Protection Against Manevolent Use of Vehicles at Nuclear Power Plants.Encl Withheld ML20059A4311993-11-0909 November 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in NOV ML20058D0471993-10-28028 October 1993 Forwards Insp Repts 50-528/93-39,50-529/93-39 & 50-530/93-39 on 930823-27.No Violations or Deviations Noted ML20058D3041993-10-19019 October 1993 Forwards Insp Repts 50-528/93-40,50-529/93-40 & 50-530/93-40 & Notice of Violation 1999-08-03
[Table view] |
Text
.. .
- !
i
,
': -
D- , s. . . , ,
( ,<
q:p '
fq"".8tQ UNITED STATES -
NUCLEAR REGULATORY COMMISSION -
.
^h '[ M50 MARIA LANE
' WALNUT CREEK. CALIFORNIA 94596-5368 -
~
';
-
p
_
Jt)t.15 199 !
. Dockets.50-528, 50-529,land 50-530
~
Arizona Public Service Compan P. 0.LBox 53999, Sta. 9082 i Phoenix, Arizona 85072-3999 Y Atiiention: William F? Conwa) .
Executive Vice P esident, Nuclear Thank 'you for your ' letter, dated July 6,1993, in response to our Notice of Violation-issued by letter, dated-June 3,1993. Your response informed us of ithe steps you have taken to correct'the items we brought to your attentio Your corrective actions will.be verified during a future inspectio .
Sincerely e
,
f Jam s . Reese,. Chief i Facilities' Radiologi al Protection Branch :
a-cc:
'Mr.LSteve-Olea, Arizona Corporation Commission
~ James A. ..Beoletto,1 Esq'., . Southern California ~ Edison Company
- Mr.4 Charles B. Brinkman, Managar, Washington- Nuclear Operations Mr?: Aubrey. Godwin,' Director, Arizona' Radiation Regulatory Age'ncy-Chairman,'Maricopa County Board.of Supervisors
. Jack R. Newman,.Esq., Newman & Holtzinger, P.C.- .
Mr;;Curtis Hoskins, Executive Vice President and Chief Operating Officer,.
Palo Verde. Services .
. Roy P. LLessey, Jr.,: Esq., Akin, Gump, ' Strauss, Hauer and Feld-Bradley W. Jones, .Esq., Akin, Gomp, Strauss, Hauer and Feld
+
. Thomas R..Bradish, Manager, Nuclear Regulatory Affairs, APS
,
19307260125 930715 T ;
PDR- ADOCK 05000529!
G PDRf I
i
'
- TEo 6
.j.jgj
,
,
,
_
-
m
.
.
,,
Dockets 50-528, 50-529, and 50-530 L Arizona Public Service Company P. O. Box 53999, Sta. 9082 Phoenix, Arizona 85072-3999 Attention: William F. Conway Executive Vice President, Nuclear
"
Thank you for your letter, dated July 6,1993, in response to our Notice of Violation issued by letter, dated June 3,1993. Your response informed us of the steps you have taken-to correct the items we brought to your attentia Your corrective. actions will be verified during a future inspectio
Sincerely James H. Reese, Chief Facilities Radiological Protection Branch cc:
Mr. Steve Olea, Arizona Corporation Commission James A. Beoletto, Esq.,- Southern California Edison Compuny Mr. Charles B. Brinkman, Manager, Washington Nuclear Operations Mr. Aubrey Godwin, Director, Arizona Radiation Regulatory Agency CFairman, Maricopa County Board of Supervisors
~ Jack R. Newman, Esq., Newman & Holtzinger, Mr. Curtis Hoskins, Executive Vice President'and Chief Operating Officer, Palo Verde Services
- Roy P. Lessey, Jr., Esq., Akin, Gump, Strauss, Hauer and Feld
- Bradley,W. Jones, Esq., Akin, Gump, Strauss, Hauer and Feld Thomas R. Bradish, Manager, Nuclear Regulatt / Affairs, APS-bec w/ copy of letter dated July 6,1993:
Docket File Resident Inspector Project Inspector G. Cook
- R. Huey B. Faulkenberry ,
'
J. Zollicoffer bec w/o copy of letter dated July 6,1993:
M. Smith-
.h,
p i-
'
.
,
, , ,n sw
.
MTYM MR ?"
- - -
TODG] .T0 PDR]
/ NO 1 S / N0 1 L
l
.)
i
- _ - _ _ _ _ _ - _ - _ _ _ _ _
, - -
.
- ,
.
.
,
.
. -
.
Arizona Public Service Company ;,,- ,. .. . ..
P.O. BOX 53999 * PHOENIX. ARIZONA 85072 3999
-
JJ
. WILLIAM F. CONWAY EKECUTivE vtCE PAC.SfDENT
""
102-02557-WFC/TRB/SAB July 6,1993 U. S. Nuclear Regulatory Commission ATFN: Document Control Desk Mail Station P1-37 _
Washington, DC 20555
.
ear Sirs: :
Subject: Palo Verde Nuclear Generating Station (PVNGS)
Units 1,2, and 3
.
Docket Nos. STN 50-528/529/530 Reply to Notices of Violation 50-528/93-18-02 and 50-528/93-18-03 File: 93-070-026 ,
Arizona Public Service Company (APS) has reviewed NRC Inspection Report _50-528/529/530/93-18 and the Notices of Violation dated June 3,1993. Pursuarit to the ~
provisions of 10 CFR 2.201, APS' responses are enclosed. Enclosure 1 to this letter is a restatement of the Notices of Violation. APS' responses are provided in Enclosure Shouid you have any questions, pleasel contact Thomas R. Bradish at (602) 393-542
Sincerely,
.
jflW WFC/TRB/SAB/rv Enclosures: " Restatement of Notices of Violation Reply to Notices of Violation cc: B. H. Faulkenberry J. A. Sloan
.- C1 - =t2 p 7n ,&r,, h x !vc 7p - .
, . .. .. .. . .. . -
- n- . . <
-
.
.
. -
-
,
.
- .--
_
.
.
.
-
.
.;
,
y
?
'
.
I r
- i
.
ENCLOSURE 1 ;
RESTATEMENT OF NOTICES OF VIOLATION 50-528/93-18-02
!
AND 50-528/93-18-03 NRC INSPECTION CONDUCTED MAY 3 THR'OUGH MAY 7,1993 -
I INSPECTION REPORT NO. 50-528/529/530/93-18-.
!
.
.! ,
.
t
-
,
<
,
'
.
'
.
.
. _ - - __
.
.
.;
~
. !
- '
. .
'
a
.
. i
-
Restatement of Notices of Violation 50-528/93-18-02 and 50-528/93-18-03 -
During an NRC inspection conducted the week of May 3 through May 7,1993, two violations of NRC requirements were identified in accordance with the General Statement i of Policy and Procedures for NRC Enforcement Actions," 10 CFR Part 2, Appendix ~ The violations are identified below:
A. Viohtion 50-528/93-18-02 RADIOLOGICAL SURVEYS ;
10 CFR 20.201(b) requires that each licensee make such surveys as may be necessary to comply with the requirements of Part 20 and which are reasonable :
under the circumstances to evaluate the extent of radiation hazards that may be ' ,
present. As defined in 10 CFR 20.201(a), " survey" means an evaluation of the radiation hazards incident to the production, use, release, disposal, or presence of radioactive materials or other sources of radiation under a specific set of l condition '
,
Contrary to the above: On November 19-20,1992, twelve 55-gallon drums of potentially radioactive oil were not surveyed as necessary to comply with the requirements of .
10 CFR 20.301,in that nonrepresentative samples of the drummed oil were used as the basis for determining whether the oil could be released for .
unrestricted us .! On November 20,1992, six 55-gallon drums of potentially radioactive oit :
v!ere not surveyed as necessary to comply with the requirements of ,
'
10 CFR 20.301, in that radiation and contamination surveys of the external surface of the drums did not detect radiation levels as high as 4 millirem per hour on contact with the surface of ;he dru , On November 20,1992, a bag marked as containing radioactive material ,
was not surveyed as necessary to comply with the requirements of 10 CFR 20.301, in that the bag was disposed of in an uncontrolled manner- -
and no radiation or contamination surveys of the bag were performe This is a Severity Level IV violation (Supplement IV). i B. Violation 50-528/93-18-03 PROCEDURAL COMPLIANCE :
,
TS 6.8.1 requires that written procedures be established, implemented and .
maintained covering the applicable procedures recommended in Appendix A of Regulatory Guide (RG) 1.33, Revision 2, February 197 Page 1 of 2-i i
m _ ____ _-__ ______ _ _ _ _ ___ .
- . - - . . .- . . . . . .. - .
,
i
'
-
,
,
,
. .
.
RG 1.33, February 1978, lists in Appendix A the following:
" Procedures for the Control of Radioactivity (For limiting ,
materials released to environment and limiting personnel exposure)"
a Licensee Procedure 75AC-9RP03, " Radiological Controls Problem Reporting dated April 5,1991, Section 2.1.3 requires that radiation protection department personnelinvestigate reported concerns and initiate appropriate documentatio ,
Section 3.1.1.6 requires that a Condition Report / Disposition Request (CRDR) be written when radioactive materialis found to be outside of a radioactive materials area. Section 3.1.1.15 requires that a CRDR be written if a personnel error is made that has adverse consequence :
~
Licensee Procedure 75AC-9RP02, " Radioactive Contamination Control," dated l
July 8,1991, Section 3.2, " Yellow, Magenta, or Yellow and Magenta Material Controls," establishes controls for use of such materials. Section 3.2.2 states that
-
these materials shall only be used within the radiologically controlled area (RCA)
or in suitably controlled and posted areas outside the RC Contrary to the above: 1 On November 24,1992, radiation protection department personnel failed to initiate a CRDR when concerns were reported involving personnel error and involving radioactive material released outside of a radioactive material are . On November 20,1992, yellow and magenta material was released for use outside the radiologically controlled area, and suitable controls and posting .
were not put in place to authorire such us .
.
This is a Severity Level IV' violation (Supplement IV).
,
.
i
.
Page 2 of 2 i
- . - - , - , , . ,,--r- , F?
i: n ;
-
.
-
.- .
,
.
-
.
'
.
1 l'
!
.
! -
t
.
.
.
~
ENCLOSURE 2 ;
i REPLY TO NOTICES OF VIOLATION 50-528/93-18-0 '!
AND 50-528/93-18-03 !
NRC INSPECTION CONDUCTED MAY 3 THROUGH MAY 7,1993 - !
INSPECTION REPORT NO. 50-528/529/530/93-18 ,
i
.
.
.
b
. !
l
5
.
'
,
.;
l
. .
,
-
1 l
. H
' '
i
.
(
! *
'.
.
-
.
' '
Reply to Notice of Violation (A) 50-528/93-18-02 l l
Admission or Denial of the Alleaed Violation l APS admits the violation. The concerns identified in this violation were identified by APS in December 1992 and a thorough investigation and evaluation of these concerns was
- performe The violations were cited following the inspector's review of the APS investigation repor ,
Reason for the Violation Notice of Violation (NOV) 93-18-02 cites three examples of failure to perform surveys that
,
were adequate to evaluate the extent of the radiation hazards present. The reasons for the violation are:
.
,
1) Failure to follow existing station operating procedure .
2) Multiple personnel errors, including inadequate supervisory contro ) Inadequacies in the program for handling and classifying used oi ,
4) Lack of procedural guidance for obtaining representative samples of oi Page 1 of G
,
, .- . .
.
..
'
.
-
r'orrective Actions Taken and Results Achieved The oil involved in the incident was either quarantined or returned to the protected are The oil was not released offsit :
APS conducted a thorough investigation of this incident and' developed a comprehensive .
.
response to the concerns identified. Corrective actions taken in response to reasons 1)
and 2) above are as follows: 9 Appropriate disciplinary action was administered to the radiation protection technicians and supervisors responsible for the release of the oil drums without adequate samples and survey Radiation protection management reiterated to supervisors the necessity of .
l reporting incidents of this nature through the station procedures developed for that purpos .
.
!
-
The Radiation Protection Support Services Manager reviewed with supervisors and senior technicians the requirements for waste sampling prior to unrestricted release. In addition, interim guidance was issued regarding waste characterization
.
and dispositio ,
T Page 2 of 6
.
f
,
- , .. .. .. . .- .. . -.
, .g
.,
+? *
'
'
-
.
.
^ ~ This' incident 'was included in the second quarter industry. eventsitraining for f radiation protect'an personnel. The need to perform adequate surveys and the ;
'
consequences of inadequate surveys were emphasized. in addition, lessons learned from this incident were presented to contract radiation protection personnel hired for the Unit 2 outag .
Corrective actions taken in response to reasons 3) and 4)~ above are as follows: .,
,_
'
.
, .
I A waste task force was created to develop guidance for the control of waste' oil to -
L ensure that the waste streams are appropriately segregated (i.e., radioactive.-
.
.
material, mixed waste, and hazardous waste), in addition, the task _ force .
addressed the programmatic deficiencies identified during the evaluation of this
,
inciden ,
!
. ,
I
Corrective Actions That Will Be Taken To Avoid Further Violations
.
Corrective actions to be taken in response to reasons 1) and 2) above are as follows: .
- ,
A manual is being formulated for lead technicians by radiation protection j
'
management delineating expectations when performing assigned tasks.' . it.is ' ,
expected that the manual will be completed by September 30,1993.'
l l
.
d Page 3 of 6
.
..
. . , . . - . _ . - - - . - - .. . - . . . . . - . . -. . . ,.
.
.: ' :
. .
,
5:
_
' i
"
( ' Corrective actions to be taken in response to reasons 3) and 4) above are as follows: ,
l
,
The findings of the. task force will be used to revise oil sampling and handling'-
procedures, as appropriate. The technicians will then be trained to the reviced'
pr,ocedures. These actions are expected to be completed by August 3,199 l
,
Procedure 75RP-9RP09, Vehicle, Equipment and Material Release, will be revised j
.
.
by August 3,1993. The revision will, in part, modify the form used to release materialin order to include such information as waste characterization and material dispositio !
-i
,
An analysis will be performed-to determine how much radioactivity could have l been released in previous oil delivered to the recycling agency' based upon the .
conservative assumption that this problem existed previously and went undetecte j
.:
This analysis will be completed by' July 23,199 :
'l
.
!
'
Date When Full Compilance Will Be Achieved
,
.t t
Full compliance was achieved on January 11,1993, when the oil and oil drums had been surveyed, accurately depicting the extent of the radiation hazard, and the contaminated -!
oil and drums were placed under the proper radiological control ,
Page 4 of 6 .;
.!
-
-
. . ., _
_ __ __-_ _ _ _ . . .
-
,
[
- L, + . ;
-
- -
,
.
U ,
Repiv to Notice of Violation (B) 50-528/93-18-03
'
'
,
t
'
..
'
Admission or Denial of the Alleaed Violation
.
t
- APS admits the violation. The concerns identified in this violation were identified by APS ,
in December 1992 and a thorough investigation and evaluation of these concerns was ,
performe The violations were cited following the inspector's review of the APS
,
._
investigation repor ..
,
!
Reason for the Violation NOV 93-18-03 cites two examples of failure to follow procedures which ' contributed to the near offsite release of radioactively contaminated oil. The reason for the violation is- f
,
personnel erro ;
i
-
.
l
<
_
,
Corrective Actions Taken and Results Achieved
' APS conducted a thorough investigation of this incident and developed a comprehensive j response to the concerns identifie The oil involved in the incident was either .
quarantined or returned to the protected area. The oil was not released offsit .
.
Page 5 of 6 3
,
_ _ . .-_ - _ . . . _
.. . - , ,
, , . _ . _ ._ . _ _ _.
x - .; ;
..,
-
-
-
~
'
. . . :
- *.
,
!
' '
< ' Appropriate disciplinary action was administered to the radiation protection technicians .
-
and supervisors responsible for the release of the oil drums without adequate samples - y i
and survey Radiation protection management reiterated to supervisors the necessity of reporting -
incidents of this nature through the station procedures developed for that purpos _
!
!
q
~
This incident was included in the second quarter industry events training for radiation !
,.
protection personnel. The need to report incidents of this nature and to comply with !
i
'
procedures for the control of radioactive material were emphasized. In addition, lessons l
~i
,
learned from this incident were presented to contract radiation protection personnel hired ;
i for the Unit 2 outage, j f
.
~
.!
Corrective Actions That Will Be Taken To Avoid Further Violations- i The actions discussed above are adequate to avoid further violation q
-
j I
Date When Full Compliance Will Be Achieved 1 l
f Full compliance was achieved on January 11,1993, after CRDR 920758 was written to evaluate this incident, and the contaminated oil and drums were adequately survey $d and placed under the proper radiological control !
. ;
i Page 6 of 6
.
'
.