CATEGORY 1 REGULAT Y INFORMATION DISTRIBUTIO SYSTEM (RIDS)
DOCKET I 05000528 05000529 05000530
SUBJECT:
Requests proposed code alternative IAW 10CFR50.55a(e) (3),as acceptable alternative to requirements of 10CFR50. 55a (e) (1),
for installation of in-line safety-related flow measurement instrument in ASME Class 3 pipe.
DISTRIBUTION CODE: A047D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: OR Submittal: Inservice/Testing/Relief from ASME Code GL-89-04 Q
05000528 0500052P 0500053 NOTES:STANDARDIZED PLANT Standardized plant.
Standardized plant.
r ACCESSION NBR:9903230162 DOC.DATE: 99/03/05 NOTARIZED: NO FACIL:STN~50q528 Palo Verde Nuclear Station, Unit 1, Arizona P'ubli ST/-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi
= STN-".50-530 Palo Verde Nuclear Station, Unit, 3, Arizona Publi AUTH.NAME AUTHOR AFFILIATION LEVINE,J.M.
Arizona Public Service Co.
(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Records Management Branch (Document Control Desk)
RECIPIENT ID CODE/NAME PD4-2 LA FIELDS,M S-BSTRACT RES/DET/EIB COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD4-2 PD AEOD/SPD/RAB NRR/DE/ECGB OGC/HDS2 RES/DET/EMMEB COPIES LTTR ENCL 1
1 1
1 1
0 1
EXTERNAL: LITCO ANDERSON NRC PDR NOAC IIIIII.III NOTE TO ALL "RZDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE.
TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)
ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:
LTTR 14 ENCL
C
Palq Verde Nuclear Generating Station James M.Levine, TEL (602)393-5300 Senior'Vice President
. =-',
.'FAX(%2)393-6077 Nuclear Mail Station 7602 P.O. Box 52034 Phoenix', AZ 85072-2034 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555-0001 102-04256-JML/AKK/RKB March 5, 1999
Reference:
Letter 102-04138 dated June 25, 1998, from J. M. Levine, APS, to USNRC.
Dear Sirs:
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Units 1, 2, and 3 Docket Nos. STN 50-528/529/530 Supplemental Information Related to Requested Code Alternative to ASME Section III Class 3 Requirements for Installation of Safety-Related Flow'easurement Instrumentation In the above referenced letter, Arizona Public Service Company (APS) requested NRC approval of a proposed code alternative in accordance with the provisions of 10 CFR 50.55a (a)(3).
APS hereby submits this letter to clarify the request made in the above reference.
Specifically, APS is requesting the proposed code alternative in accordance with 10 CFR 50.55a (a)(3), as an acceptable alternative to the requirements of 10 CFR 50.55a (e)(1), for the installation of an in-line safety-related flow measurement instrument in an ASME Class 3
pipe.
Additionally, APS has performed an evaluation in accordance with 10 CFR 50.59 to determine that, following NRC approval of the requested code alternative, no unreviewed safety questions exist and no change to station Technical Specifications is required.
Finally, APS has determined that implementation of the proposed code alternative would not require an amendment to the operating license.
Please contact Mr. Scott Bauer at (602) 393-5978 if you have any questions.