h]QQ Etucraic

~

July 8,1993 CAway Phn Nuclear Regulatory Commission Document Control Desk Washington,DC 20555 ULNRC-2818

Dear Sir:

DOCKET NUMBER $0-483 CALLAWAY PLANT UNIT I FACILITY OPERATING LICENSE NPF-30 MONTHLY OPERATING REPORT JUNE.1993 The enclosed Monthly Operating Report for June,1993 is submitted pursuant to section 6.9.1.8 of the Callaway Unit 1 Technical Specifications.

k_

W. R. CampbcIl Manager, Callaway Plant WRC/DEY11AWfAM/ M/ crc Enclosure cc: Distribution attached

/ I

~

9 3 0'7 f 0'O f3 5 9 3 0 6 3 0 '

PDR' ADOCK 05000483 R PDR g

[/

t ,,

j I&vkog A11ress' PO. Box 620 Fttart, MO 65251

I

..  :- i

,_. . ]

,cc distribution for ULNRC-2818 with enclosures Mr. I. N. Jackiw, Cidef Reactor Projects Section 3C U.S. Nuclear Regulatory Commission Region til 799 Roosevelt Road Glen Ellyn,IL 60137 Mr. L. R. Wharton (2 copics)

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 1 White Flint, North, Mail Stop 13E21  !

1155 Rockville, MD 20852 NRC Resident Inspector Manager, Electric Department Missouri Public Senice Commission P.O. Box 360 Jefferson City,MO 65102 i

s t

~

' .DOCKBT NO, '50-483 UNIT NAME CALLAWAY UNIT I DATE 7-08-93 COMPLETED BY J. B. McInvale TELEPHONE 314/676-8247 PART A OPERATIONS

SUMMARY

The plant operated at approximately 100% power for the entire month with the following exception:

On 6-09-93 load was reduced to 91% to perform repairs on low pressure feedwater heaters. Full power -

operation resumed on 6-10-93.

PART B PORV AND SAFETY VALVE

SUMMARY

Nonc _

b I

Page1of4

~

PART C -

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO 50-483 UNIT Callaway Unit 1 DATE 7-08-93 COMPLETED BY J. B. McInvale TELEPIlONE 314/676-8247 MONTH: JUNE 1993 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY (MWe-Nc0 DAY (MWe-Nc0 1 1155 17 1132 2 1148 18 1134 3 1147 19 1136 4 1155 20 1141 5 1158 21 1135 6 1153 22 1136 7 1132 23 1133 8 1136 24 1134 9 1098 25 1146 10 1080 26 1142 11 1140 27 1134 12 1140 28 1133 13 1135 29 1128 14 1137 30 1105 15 1146 16 1137 Page 2 of 4 m-

. :i PART D

, OPERATING DATA REPORT DOCKET NO. 50-483 UNIT NAME CALLAWAY UNIT 1 DATE 7-08-93 COMPLETED BY J. B. McIm ale TELEPIIONE 314/676-8247 -

OPERATING STA1US OTD) (CUM)

1. REPORTING PERIOD. JUNE 1993 OROSS IlOURS IN REPORTING PERIOD: 720. 4343 74,748.5 2 CURRENTLY AtJFl!ORIZED POWER LFvrL (MWt): 3565 M AX. DEPEND. CAPACITY (MWe-Net): 1120 DESIGN ELECTRICAL RATING (MWe-Net): 11?!
3. POWER LEVEL TO WIIICII RESTRICTED (IF ANYs (MWe-Net):
4. REASONS FOR RFSTRICTION (IF ANY):

Tills MONTil YR TO DATE CUMULATIVE

5. NUMBER OF llOURS REACTOR WAS CRITICAL 720.0 4,343.0 65,720.7
6. REACTOR RESERVE SlitTFDOWN llOURS 0 0 0
7. IIOURS GENERATOR ON llNE 720.0 4,343.0 64,398.7 8 UNIT RESERVE S1RTFDOWN IIOURS.... . - . - 0 0 0
9. OROSS TIIERMAL ENEROY OENERATED (MWII)... 2,$30,244 15,130,446 216,210,396
10. OROSS ELECTRICAL ENEROY OENERATED (MWil).. 857,276 5,208,029 73,769,92$

II. NET ELECTRICAL ENEROY OENERATED (MWII) 817,544 4,971,658 70,145,756

12. > ACTOR SERVICE FACTOR.

. 100.0 100.0 87.9

13. REA )R AVAILABILITY FACTOR. 100.0 100.0 87.9
14. UNIT SERVICE FACTOR .-- 100.0 100.0 86.2 ,

I $. UNIT AVAILABILITY FACTOR - 100.0 100.0 86.2

16. UNIT CAPACITY FACTOR (Using MDC).- 101.4 102.2 83.8
17. UNIT CAPACITY FAC10R (Uning Design MWe). 97.0 97.8 80.1 18 UNIT FORCED OLTFAGE RATE _ 0.0 0.0 2.7
19. SlILTFDOWNS SCllEDULED OVER NEXT 6 MONTilS (TYPE, DATE, AND DURATION OF EACil): Refueling; Date: 10/01/93 Duration: 56 days
20. IF SIIUT DOWN AT END OF REPORTING PERIOD, ESTIMATE DATE OF STARTUP:

Page 3 of 4

~,.4

' 'L . .

PART E UNIT SIIU1 DOWNS AND PO%TR REDUCTIONS DOCKET NO. 50-483 UNIT NAME CAtlAWAY UNTT 1 DATE 7.08-93 COMPLETED BY 1 B. McInvale 1T1EPIIONE 314'67 4 247 -

REPORT MONTH: JUNE 1993 METIIOD OF TYPE SIRTI'11NG DOWN F: FORCED DURATION TIIE REACTOR OR lia DATE- 5: SCIIEDULED (FLOURS) REASON REDUCING POWER CORRECITVF/ACrlONSTOMMENTS

SUMMARY

I REASON MET 110D j' A EQUIPMENTFAILURE(EXPIAIN) 1: MANUAL i

B: MAINT,OR1EST 2: MANUAL SCRAM

j. C: REFUELING 3: AUTOMATICSCRAM D- REGULATORY RESTRICTION 4: 011IER(EXPLAIN)

E: OPERATORTRAINING AND

, LICENSE EXAMINATION I

F: ADMINISTRATION 0: OPERATIONALERROR(EXPIAIN)

II: OTHER(EXPLAIN)

I t

Page 4 of 4 '

___..m_ _-. _ - - . . - _ - s ,... . .;_.. . . . . . ~ . . . . . . - - .L, . . J .-