Carolina Power & Light Company Brunswick Nuclear Plant P. O. Box 10429 Southport, NC 28461 0429 June 4, 1993 FILE: B09-13510C BSEP/93-0085 U. S. Nuclear Regulatory Commission Washington, DC 20555 Attn: Document Control Desk BRUNSWICK STEAM ELECTRIC PLANT UNITS 1 AND 2 DOCKET NOS. 50-325 AND 50-324 LICENSE NOS. DPR-71 AND DPR-62 MONTHLY OPERATING REPORT Centlemen:
In accordance with Technical Specification 6.9.1.11 for the Brunswick Steam Electric Plant, Units 1 and 2, Carolina Power & Light Company herewith submits the report of operating statistics and shutdown experience for the month of i May 1993.
Very truly yours, ;
1 h
l M. Brown, Plant Manager - Unit 1 i Brunswick Nuclear Plant RHR/bc MSC/93-8524 Enclosures cc: Mr. R. A. Anderson Mr. R. G Oehl Mr. T. C. Bell Mr. R. M. Parsons Mr. R. M. Coats Mr. R. L. Prevatte Mr. S. D. Ebneter Mr. E. Scott Mr. P. S. Gore Mr. M. S. Staton Ms. E. M. Harrelson Ms. T. A. Ward Mr. M. D. Hill Mr. C. C. Warren Mr. C. S. Hinnant Mr. D. B. Waters Mr. N. B. Le Mr. F. Yost Ms. Peggy Morris INPO Mr. W. R. Murray Regulatory Compliance (Document File) 160019
- BR62inCI M8S$34 }
b
CP&L CO PLANT PERFORMANCE DATA SY 34 PAGE i RUN DATE 06/03/93 APedNDIX B - AVERAGE DAILY POhua LEVEL RPD39-000 RUN TIME 09:05:35 BRUNSWICK UNIT 1 DOCKET NO. 050-0325 COMPLETED BY RONALD RUMPLE
. TELEPHONE (919)457-2752 ,
1 MAY 1993 DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY PCWER LEVEL ,
(MWE-NET) (MWE-NE t')
1 -9 17 -7 j 2 -9 18 -7 ,
3 -9 19 -7 4 -9 20 -7 5 -9 21 -8 ;
6 -9 22 -8 7 -8 23 -7 8 -9 24 -7 ,
9 -10 25 -7 10 -9 26 -7
+
11 -8 27 -7 12 -7 28 -7 13 -8 29 -7 14 -8 30 -7 15 -8 31 -7 l
16 -8 s
i 1.16 - 8 l
t
CP&L CO PLANT PERFORMANCE DATA SY IM PAGE
'RUN DATE 06/03/93 OPERATING DATA REPORT RPD36-000 RUM TIME 09:05:33 BRUNSWICK UNIT 1 DOCKET NO. 050-0325 COMPLETED BY RONALD RUMPLE OPERATING STATUS TELEPHONE (919)457-2752
- 1. UNIT NAME: BRUNSWICK UNIT 1 NOTES
- 2. REPORTING PERIOD: MAY 93 l 3. LICENSED THERMAL POWER (MWT): 2436
- 4. NAMEPLATE RATING (GROSS MWE): 867.0
- 5. DESIGN ELECTRICAL RATING (NET MWE): 821.0
- 6. MAX DEPENDABLE CAPACITY (GROSS MWE): 791.0
- 7. MAX DEPENDABLE CAPACITY (NET MWE): 767.0 -------------------------------
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): I
- 10. REASONS FOR RESTRICTION IF ANY:
THIS YR TO CUMUL MONTH DATE ATIVE l
- 11. HOURS IN REPORTING PERIOD 744.00 3623.00 142055.00
- 12. NUMBER OF HOURS REACTOR CRITICAL .00 .00 87881.32 !
- 13. REACTOR RESERVE SHUTDOWN HRS .00 .00 1647.10 !
- 14. HOJRS GENERATOR ON LINE .00 .00 84201.37
- 15. UNIT RESERVE SHUTDOWN HOURS .00 .00 .00
- 16. GROSS THERMAL ENERGY GEN. (MWH) .00 .00 183021943.70
- 17. GROSS ELEC. ENERGY GEN. (MWH) .00 .00 60019285.00-
- 18. NET ELEC. ENERGY GENERATED (MWH) -5865.00 -32157.00 57685049.00
- 19. UNIT SERVICE FACTOR .00 .00 59.27
- 20. UNIT AVAILABILITY FACTOR .00 .00 59.27
- 22. UNIT CAP. FACTOR (USING DER NET) .96 -1.08 49.46
- 23. UNIT FORCED OUTAGE RATE .00 .00 16.07
- 24. SHUTDOWNS SCHED. OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP: 9/26/93
- 26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION) : FORECAST ACHIEVED INITIAL CRITICALITY -------- --------
INITIAL ELECTRICITY -------- --------
COMMERCIAL OPERATION -------- --------
1.16 - 9
4 DOCKET NO. 050-0325 +
UNIT NAME Brunswick i DATE _ June 1993 CDMPLETED BY Ronald Rumple TELEPHONE 919-457-2752 UNIT SHUTDOVNS AND POVER REDUCTIONS REPORT MONTH May 1993 HETH00 0F LICENSEE DURATION SHUTTING DOVN EVENT SYSTEM CODE COMPONENT CAUSE & CORRECTIVE ACTION TO NO. DATE TYPE (1) (HOURS) REASON (2) REACTOR (3) REPORT NO. (4) CODE (S) PREVENT RECURRENCE 93-002 930308 $ 744.0 C 6 N/A ZZ ZZZZZZ Normal refueling outage.
1: Type 2: Reason 3: Method 4: System Code: 5. Component Code F - Forced A- Equipment Failure 1- Manual Instruction for Instructions for S - Scheduled (explain) 2- Manual Scram preparation of data entry preparation of data B- Maintenance or test 3- Autenatic scram sheets for Licensee Event entry sheets for LER C- Refueling 4- Continuations Report (LER) file from file from IEEE D- Regulatory 5- Load reductions IEEE Standard 805-1983, Standard 803A-1983, restriction 6- Other per NUREG-1022, per NUREG-1022.
E- Operator Training & Section VI, Item 13.b Section VI, Item 13.c License Examination F- Adninistrative G- Operational error (explain)
H- Other (explain) 4 u . . , . . . . - . . , . - - - - - , - r -e -v.,..-.- 4 m...-#.,. . -w .,. .~< . . - .. -
~
CP&L CO PLANT-PERFORMANCE DATA SY EM PAGE i RUN DATE 06/03/93 APrENDIX B - AVERAGE DAILV POhgR LEVEL RPD39-000 RUN TIME 09:05:35 BRUNSWICK UNIT 2 DOCKET NO. 050-0324 COMPLETED BY RONALD RUMPLE TELEPHONE (919)457-2752 MAY 1993 DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (MWE-NET) (MWE-NET) 1 -13 17 112 2 -13 18 169 3 -15 19 184 4 -15 20 204 5 -15 21 211 6 -15 22 363 7 -14 23 387 8 -15 24 447 9 -16 25 504 10 -15 . 26 521 11 -14 27 714 12 -14 28 751 13 -14 29 662 14 -14 30 762 15 29 31 771 16 110 1.16 - 8 l
l
'CP&L CO PLANT PERFORMANCE DATA SY EM PAGE A RUN DATE 06/03/93 OPERATING DATA REPORT RPD36-000 RUN TIME 09:05:38 BRUNSWICK UNIT 2 DOCKET NO. 050-0324 COMPLETED BY RONALD RUMPLE OPERATING STATUS TELEPHONE (919)457-2752 )
- 1. UNIT NAME: BRUNSWICK UNIT 2 NOTES I
- 2. REPORTING PERIOD: MAY 93 l
- 3. LICENSED THERMAL POWER (MWT): 2436 ;
- 4. NAMEPLATE RATING (GROSS MWE): 867.0 j
- 5. DESIGN ELECTRICAL RATING (NET MWE) : 821.0 i
- 6. MAX DEPENDABLE CAPACITY (GROSS MWE): 782.0 J
- 7. MAX DEPENDABLE CAPACITY (NET MWE): 754.0 -------------------------------
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE):
- 10. REASONS FOR RESTRICTION IF ANY:
l THIS YR TO CUMUL MONTH DATE ATIVE
- 11. HOURS IN REPORTING PERIOD 744.00 3623.00 154079.00
- 12. NUMBER OF HOURS REACTOR CRITICAL 744.00 778.30 92869.68
- 13. REACTOR RESERVE SHUTDOWN HRS .00 .00 .00
- 14. HOURS GENERATOR ON LINE 388.78 388.78 87543.45
- 15. UNIT RESERVE SHUTDOWN HOURS .00 .00 .00
- 16. GROSS THERMAL ENERGY GEN. (MWH) 572958.89 572958.89 184699813.75
- 17. GROSS ELEC. ENERGY GEN. (MWH) 173135.00 173135.00 59723604.00
- 18. NET ELEC. ENERGY GENERATED (MWH) 160827.00 136437.00 57183997.00
- 19. UNIT SERVICE FACTOR 52.26 10.73 56.82 >
- 20. UNIT AVAILABILITY FACTOR 52.26 10.73 56.82 +
- 22. UNIT CAP. FACTOR (USING DER NET) 26.33 4.59 45.21
- 23. UNIT FORCED OUTAGE RATE .00 .00 13.46
- 24. SHUTDOWNS SCHED. OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP:
- 26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION): FORECAST ACHIEVED i INITIAL CRITICALITY -------- --------
INITIAL ELECTRICITY -------- --------
COMMERCIAL OPERATION -------- --------
1.16 - 9
DOCKET NO. 050-0324 LNIT NAME Brunswick 2 DATE . Jung 1993 CCWLETED BY Ronald Rumple .
TELEPHONE 919-45/-2/52 LNIT SHUTDOWh5 AND POWER REDUCTIONS i REPORT MONTH May 1093 METHOD OF LICENSEE DURATION SHUTilNG 00WN EVENT SYSTEM CODE COMPONENT CAUSE & CORRECTIVE ACTION TO NO. DATE TYPE (1) 00URS) REASON (2) REACTOR (3) REPORT NO (a) OX)E (5) PREVENT RECURRENCE e
'93-001 920430 5 351.4 8 4 1-92-12 TG XC To complete the scheduled Continued maintenance outage for from previous backlog reduction. Also, famth structural inspections completed. j 93 003 930517 5 3.9 8 N/A N/A JJ TG Mein Turbine Overspead Testing
- This event was previously 92-025. .
1: Ty.pg 2: Reason 3: Method 4: System Code: 5. Comoommt Code f - Forced A- Equipment Failure .1 Manual Instruction for Instructions for 5 - Scheduled (explain) 2- Manual Scram preparation of data entry preparation of data B- Maintenance or test 3- Automatic scram sheets for Licensee Event entry sheets for LER C- Refueling 4- Continuations Report (LEO) file from file from lEEE D- Regulatory 5- Load reductions IEEE Standard 805-1983. Standard 803A-1983. i restriction 6- Other per NUREG-1022. per NUREG-1022.
E- Oparator Training & Section VI. Item 13.b Section VI. Item 13.c License Examination F- Administrative G- Operational error (explain)
+ H- Other (explain)