SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION OF USl A-46 PROGRAM IMPLEMENTATION AT BRUNSWICK STEAM ELECTRIC PLANT. UNIT NOS 1 AND 2 DOCKET NOS. 50-324 AND 50-325 OPERATING LICENSE NOS. DPR-71 AND 62
1.0 BACKGROUND
On February 19,1987, the NRC issued Generic Letter (GL) 87-02, " Verification of Seismic Adequacy of Mechanical and Electrical Equipment in Operating Reactors, Unresolved Safety issue (USI) A-46." In the GL, the NRC staff set forth the process for resolution of USl A-46, and encouraged the affected nuclear power plant licensees to participate in a generic program to resolve the seismic verification issues associated with USl A-46. As a result, the Seismic Qualification Utility Group (SOUG) developed the
" Generic implementation procedure (GIP) for Seismic Verification of Nuclear Plant Equipment," Revision 2 (GIP-2, Reference 1).
On May 22,1992, the NRC issued Supplement 1 to GL 87-02 including the staff's Supplemental Safety Evaluation Report No. 2 (SSER-2, Reference 2), pursuant to the provisions of 10 CFR 50.54(f), which requ, red that all addressees provide either (1) a commitment to use both the SQUG commitments and the implementation guidance described in GlP-2 as supplemented by the staff's SSER-2, or (2) an alternative method for responding to GL 87-02. The supplement also required that those addressees committing to implement GIP-2 provide an implementation schedule as well as detailed information including the procedures and criteria used to generate the in-structure response spectra (IRS) to be used for USl A-46.
By letter dated September 19,1992 (Reference 3), Carolina Power & Light Company (CP&L), the licensee, provided its response to Supplement 1 to GL 87-02 for the Brunswick Steam Electric Plant (BSEP) Unit Nos.1 and 2. In that letter, CP&L committed to follow the SQUG commitments set forth in GlP-2, including the clarifications, interpretations, and exceptions identified in SSER-2. The staff issued its evaluation of the licensee's response by letter dated November 23,1992 (Reference 4).
By letter dated September 15,1995 (Reference 5), CP&L submitted a summary report containing the results of the USI A-46 program implementation at BSEP. By letter dated June 17,1997 (Reference 6), CP&L provided its response to the staffs request for additional information (RAl) dated March 12,1997 (Reference 7).
ENCLOSURE 9908110053 990805 PDR ADOCK 05000324 P
PDR c
2 This report provides the staffs evaluation of the licensee's USI A-46 implementation program based on the staffs review of the summary report, supplemental information, clarification and documentation provided by the licensee in response to the staffs RAls.
2.0 DISCUSSION AND EVALUATION CP&L's walkdown summary report (Reference 5) provides the licensee's implementation results of the USl A-46 program at BSEP. The report identifies a safe shutdown equipment list (SSEL) and contains a summary of the screening verification and walkdown of mechanical and electrical equipment, as well as the relay evaluation. The report also contains the evaluation of seismic adequacy for tanks and heat exchangers, cable and conduit raceways, and outlier identification and resolution including proposed schedules. By letter dated July 11,1997 (Reference 8), the licensee provided an updated equipment modification schedule for resolving outliers. By "BSEP-98-0145, Informs That Util Completed Final Outlier Resolutions for Bsep,Units 1 & 2,in Response to GL 87-02 Re USI A-46.Outlier Resolutions Are Documented in Encl Partial Calculations 1SEIS-0028 & [[SSC" contains a listed "[" character as part of the property label and has therefore been classified as invalid.|letter dated September 11,1998]] (Reference 9), the licensee informed the staff that it had completed all outlier resolutions for both BSEP, Units 1 and 2.
2.1 Seismic Demand Determination The licensee stated in Reference 5 that the A-46 equipment are located in four Category I structures. The four structures are the reactor / containment, control, diesel generator, and service water intake buildings. The seismic input ground motion in the horizontal
- direction for the diesel generator building and the control building is the design basis earthquake (DBE), which is a Newmark shape spectrum normalized to a peak ground acceleration of 0.16. The seismic input ground motion in the horizontal direction for the 9
service water intake building and the reactor / containment building is the RG 1.60 spectrum with a peak ground acceleration of 0.16g. The vertical ground motion component is taken as two-thirds of the horizontal component. The seismic input motions and the method for developing the IRS had been evaluated and accepted by the staff, and were documented in Reference 4. The licensee stated in Reference 5 that the IRS, as discussed in the 120-day response to Supplement No.1 to GL 87-02, were used in the A-46 walkdowns and evaluations. Conservative design IRS were chosen and generated. The rtaff finds this seismic demand acceptable for use in the A-46 program.
2.2 Seismic Evaluation Personnel The seismic capability engineers (SCEs) for the BSEP walkdown consisted of numerous 1
experts of CP&L and EQE Engineering Consultants identified in Section 2.2 of the Seismic Evaluation Report (Reference 5). Two engineers from VECTRA Technologies performed the third-party audit. The resumes of the SCEs and the independent reviewers were also provided in Appendix A of Reference 5.
The SSEL items were compiled in accordance with the guidelines of Section 3
" Identification of Safe Shutdown Equipment," and Appendix A, " Procedure for identification of Safe Shutdown Equipment" of the gip-2. The licensee indicated that the BSEP Plant Operations personnel who have a comprehensive understanding of the plant
o i
3 layout and the function and operation of the equipment and systems in the plant have also reviewed the SSEL for compatibility with the approved plant normal and emergency operating orocedures used for shutdown of the plant and associated operator training.
The staff finds that the SCEs' qualifications fully satisfy the provisions of GIP-2. The staff also notes that the " Third Party" reviewer and the SCEs are highly recognized for their experience in the field of seismic evaluation of structures, systems and components.
2.3 Safe-Shutdown Path GL 87-02 specifies that the licensee should be able to bring the plant to, and maintain it in, a hot shutdown condition during the first 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following a safe shutdown earthquake (SSE). To meet this provision, the licensee, in Reference 5, addressed the following plant safety functions: reactor reactivity control, pressure control, inventory control, and decay heat removal. Primary and alternate safe shutdown success paths including their support systems and instrumentation were identified for each of these safety functions to ensure that the plant is capable of being brought to, and maintained in, a hot shutdown condition for 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following an SSE. Section 4 of Reference 5 provides the safe shutdown success paths. Appendix B of Reference 5 provides the SSEL.
Brunswick plant operating procedures direct the operators to go to cold shutdown condition following a seismic event. The reactor decay heat removal function is accomplished by relieving steam from the reactor via the safety / relief valves into the suppression pool. The reactor coolant system (RCS) inventory is controlled by injecting water into the RCS by one train of the core spray system. During the early stages of the plant shutdown procedures, decay heat removalis achieved by placing one train of the residual heat system (RHR)in the suppression pool cooling (SPC) mode. During the SPC mode, the RHR system takes suction from, and discharges to, the suppression pool via the RHR heat exchangers. in the later stages of the plant shutdown, decay heat removalis achieved by placing one train of the RHR in the shutdown cooling (SDC) mode. During the SDC mode of RHR, the system takes suction from, and discharges to, the reactor water recirculation loop via the RHR heat exchangers. The other train of RHR is available as an alternate success path.
The piant Operations Department reviewed the safe shutdown success paths and concluded that the plant operating procedures and operator training were adequate to establish and maintain the plant in a safe shutdown condition using the equipment identified in Appendix B.
The staff concludes that the approach to achieve and maintain cold shutdown for 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> during and following a seismic event is acceptable.
2.4 Seismic Screenino Verification and Walkdown Mechanical and Electrical Eauipment The seismic screening of components is documented on Screening Evaluation Work Sheets (SEWS) in accordance with the requirements of GIP-2. SEWS are sorted by the 20 classes of equipment covered in GlP-2 (Reference 1) and the "other" equipment class
1 4
not covered in GIP-2. The results are further condensed and summanzed on Screening Verification Data Sheets (SVDS), sorted by equipment class and presented as Appendix C of the Seismic Evaluation Report of Reference 5.
2.4.1 Adeauacy of Eauioment Seismic Capacity Compared to Seismic Demand The licensee stated in Reference 5 that, at the 5% of critical damping, SQUG Bounding Spectrum enveloped the Brunswick DBE ground motion response spectrum, and that the GIP-2 Method A was used for equipment located within 40 feet of the effective grade whose natural frequencies are greater than 8 Hz. The staff made a comparison of the IRS at about 40 feet above the effective grade, to the design ground spectrum, and found that the ratio of the IRS to the design ground spectrurn is about 1.5. Therefore, the licensee has appropriately used GIP-2, Method A. The licensee also used GIP-2, a
Method B when Method A was not applicable. Graphs comparing the 1.5 Bounding
{
Spectrum to IRS for the reactor, control, diesel generator, and service water intake buildings were generated to evaluate seismic capacity versus seismic demand.
The staff noted that the licensee has followed the GIP-2 procedures for comparing equipment seismic capacity to seismic demand, and concludes that the evaluation is adequate for the resolution of A-46.
2.4.2 Assessment of Eauipment " Caveat" In order to apply the experience-based approach and use the equipment seismic capacity defined in GlP-2, the plant-specific equipment must meet some restrictions or caveats described in GIP-2. The licensee indicated, in Reference 5, that the SCEs verified that the caveats listed in Appendix B of GIP-2 for each equipment class were met for BSEP. Caveats are the inclusion and exclusion rules, which represent specific characteristics and features particularly important for seism lc adequacy of a specific class of equipment when the equipment seismic capacity is determined based on the experience-based data. The use of" meeting the intent of the caveats"is typically intended to demonstrate seismic adequacy of equipment that did not meet the specific wording in certain caveats, but is deemed seismically adequate based on the judgment of the SCE.
The applicable caveats and the results of the licensee's evaluations for conformance with the caveats were documented in SEWS and SVDS (Appendix G of the Seismic Evaluation Report of Reference 5). In many cases, equipment which do not meet the GlP-2 caveats, were considered as outliers and were documented in the Outlier Seismic Verification Sheet (OSVS) of the BSEP summary report for USl A-46 resolution in some cases, if an item of equipment was judged to meet the intent of the caveats, but the specific wording of the caveat rule is not met, then the equipment item was considered to have met the caveat rule, in accordance with GIP-2. Equipment items that met the intent rather than the specific wording of the caveats are summarized in Appendix D of the Seismic Evaluatien Report of Reference 5.
in its response of June 17,1997 (Reference 6), to the staff's RAl, dated March 12,1997 (Reference 7), the licensee provided supplemental information, for some equipment i
J
E
]
5 items, to demonstrate how the intents of certain caveats were met rather than the wordings. For instance, for numerous backup N2 discharga valves and pressure relief valves as well as the scram outlet isolation valves, the licensee identified them as
{
meeting the intent but not the letter of the equipment class caveat. These valves a'e mounted on a pipe smaller than one inch in diameter. One inch js the lower bound pipe size supporting valves in the earthquake experience equipment clasa The concern is that valves with heavy operators on smalllines may cause an overstressed condition in the adjacent piping. There is no concern if the valve, the operator, and the pine are well-supported and anchored to the same support structures, in response to the staff's concern, the licensee stated that in all such instances, the valve, operator and pipe are i
well-supported and anchored to the same support structures.
In Appendix 0 of the Seismic Evaluation Report of Reference S, the licensee also identified some adjacent cabinets as meeting the intent, but not the letter of the j
equipment class caveat. These adjacent cabinets are not bolted together.. The concem l
is that adjacent cabinets not bolted together may respond out of phase to one another and impact each other during an earthquake. In response to the statt's concem, the licensee stated that evaluations have been performed in all such instances and the configuration was determined to be acceptable based on any of the fcl lowing:
)
(1) determination that either !.he existing anchorage or bracing are adequate to preclude i
impact with the adjacent cabincts; (2) existing gap was judged adequate to preclude impact with the adjacent cabinato due to the stiffness of the cabinets in the lineup; or (3) the missing hardware parts (e.g., bolts) were installed.
I
' in general, the staff finds that the seismic adequacy determination for equipment identified in Section 5 of the BSEP summary report conformed with the GIP-2 guidance on the caveats, and is acceptable in the instances where the intent rather than the wording of the caveats was met.
I 2.4.3 Eauipment Anchora,;Le The GlP specifies the following four steps in regard to equipment anchorage verification:
(1) anchorage installation inspection, (2) anchorage capacity determination, (3) seismic demand determination, and (4) comparison between capacity and demand.
The licensee indicated that its screening approach for verifying the seismic adequacy of equipment reachorage is based cn a combination of field inspections, analytical calculations and engineering judgment.
During the prescreening of equipment, existing calculations, drawings, vendor manuals, and other plant documentation were reviewed to determine the type of anchorage used for the specific component. If the information was available, it was documented in the SEWS for reference by the SCEs during the walkdown. Special review teams (SRTs) used this information to confirm that plant documentaticn accurately represented the as-installed anchorage, if no information was available, this was noted in the prescribing notes so that the SRT could identify the as-installed anchorage and incorporate it into the SEWS.
p 1
[.,
u
[.
i 6
During the field inspection process, the SRT noted attributes relating to equipment characteristics, type of anchorage, size and location of anchorage, installation adequacy,
- a
. embedment length, gaps, spacing, and edge distance. Expansion anchors were also
)
l checked for tightness. In its Seismic Evaluation Report (Reference 5), the licensee I
indicated that the SRT typically used a box or open-end wrench on the bolt head or nut and applied a sufficient torque by hand to determine if the anchor was wrench tignt. This L
inspection was performed on all accessible anchorages.
in cases where the SRT could confirm that the installed anchorage configuration matched available plant documentation, the anchorage caveat was marked as seismically adequate. If no plant documentation was available but the SRT was able to specifically identify and accept the as-built anchorage attributes, engineering judgment was utilized. if no plant documentation was available and the SRT was unable to clesrly identify and evaluate all attributes of the anchorage, then the component anchorage was identified as requiring analytical calculations to compare its seismic capacity against the seismic demand.
In Section 5.1.3 of the Seismic Evaluation Report of Reference 5, the licensee stated that most components were determined to have adequate anchorage capacity based on a combination of field inspection, analytical evaluation, and engineering judgment. Any components whose anchorage capac.ty could not tLa verified using these methods were identified as outliers. As discussed in Section 2.9 of this Safety Evaluation (SE), all such outliers have been resolved by the licensee as indicated in its "BSEP-98-0145, Informs That Util Completed Final Outlier Resolutions for Bsep,Units 1 & 2,in Response to GL 87-02 Re USI A-46.Outlier Resolutions Are Documented in Encl Partial Calculations 1SEIS-0028 & [[SSC" contains a listed "[" character as part of the property label and has therefore been classified as invalid.|letter dated September 11, 1998]] (Reference 9).
The staff finds that the licensee has followed the GIP-2 procedures for verifying equipment anchorage adequacy. Therefore, the equipment anchorage evaluation is considered acceptable for the resolution of USl A-46.
2.4.4 Seismic SpatialInteraction Evaluation The SRT seismic walkdowns included evaluation for potential seismic interaction concerns. The licensee stated that the evaluation was performed in accordance with the GIP-2 provisions in Section 11.4.5 and Appendix D. The interactions of concern are 1) proximity effects,2) structural failure and failing,3) flexibility of attached lines and cables, and 4) any other possible interactions. The SRT evaluated the possible seismic spatial intractions for all the safe shutdown components and documented them on the SEWS.
Several seismic interaction concerns including some housekeeping issues were identified during the walkdown and were identified as outliers in Appendices E1 and E2 of the Seismic Evaluation Report of Reference 5. As discussed in Section 2.9 of this SE, all these outfiers have been resolved by the licensee as indicated in its letter dated September 11,.1998 (Reference 9).
In general, the staff finds the licensee's spatial interaction evaluation acceptable for the
(
resolution of USI A-46.
i r
i e
7
)
2.5 Tanks and Heat Exchange _rS The licensee stated that tanks and heat exchangers were evaluated as stated by the l
requirements of GlP-2 and documented them on Equipment Class 21 SEWS. Although some of the anchorages for the tanks and exchangers were determined to be adequate through engineering judgment, anchorage calculations were performed for most of the anchorages for tanks and heat exchangers. Large flat bottom tanks, such as the Condensate Storage Tank, Refueling Water Storage Tank, and Primary Water Storage Tank, are not on the SSEL list because at Brunswick these large flat bottom tanks are not needed for safe shutdown function during an earthquake. Therefore, no outlier relating to large flat bottom tanks were noted. One accumulator was identified as an outlier for problems related to its proper connection to the frame, corrosion at the frame base, and proper load path from the accumulator to the rack. The problems were resolved by calculations. In general, the staff finds the licensee's evaluation of tanks and heat exchangers adequate for the resolution of USl A-46.
2.6 Cable and Conduit Racewats On April 21,1992, both units of the Brunswick plant were shut down because of concems with the seismic qualification of masonry walls 3 the Diesel Generator Building.
CP&L management committed to numerous pre-startu-
' ions to improve the condition of the plant. Two walkdowns were performed. The ir
/ of the deficiencies identified were related to conduit or cable tray systems, and they.,re resolved using either plant design basis documents or the GIP-2 methodology. An A-46 raceway walkdown was later performed, and F. > walkdown included all areas of the plant containing safety-related trays a. J conduits, with emphasis on areas known from prior experience to be heavily congested and /or loaded. A limited number of samples of the raceway system were selected for analysis for the A-46 program in addition to the large number of calculations and modifications generated during the previous programs. Four outliers were identified. Two outliers were resolved by analysis. The remaining two outliers were resolved by physical modifications and additional analysis. The staff concludes that the licensee's evaluation of the cable and conduit raceways is adequate for the resolution of A-46.
j 2.7 Seismic Adecuacy of Essential Relavs The purpose for the review of seismic adequacy of essential relays is to determine if the plant's safe shutdown systems could be adversely affected by relay malfunction in the event of an SSE. The licensee stated that its relay evaluations were performed in accordance with the procedure outlined in GIP-2 and in EPRI NP-7148-SL. The licensee also stated that, for the relays identified as low ruggedness and the relays which could not be shown as seismically adequate, procedures and techniques described in EPRI NP-7148 were used to evaluate the consequences of a malfunction of these relays on system performance. Relays for which chatter did not affect systera performance were classified as " chatter acceptable." Relays for which chatter would affect system performance, but for which operator actions would mitigate the relay chatter impact were classified as " operator action" acceptable. Those relays which were neither chatter acceptable nor operator action acceptable were listed as outliers. Appendix F of the
8 Relay Evaluation Report provides the details of some of the licensee's relay chatter evaluations. Appendices G and H provide the summary of the relay chatter evaluations for all of the essential relays for Units 1 and 2.
In Section 2.3 of the Relay Evaluation Report of Reference 5, the licensee stated that, as a result of its relay evaluations, a total of 76 relays and process switches were identified as potential outliers and were still under evaluation. In Reference 9, the licensee indicated that the evaluation has been completed. These relays and process switches have been shown to be chatter acceptable. The results of the relays and switches evaluation have been documented in a revision to the "USl A-46 Relay Evaluation Report." The staff finds the licensee's seismic relay evaluation to be reasonable and acceptable.
2.8 Human Factors Aspect As part of the resolution to the " Veri 6 cation of Seismic Adequacy of Mechanical and Electrical Equipment in Operating Reactors," USl A-46, the SQUG developed GlP-2 for use in part by licensees to identify and verify an SSEL and ensure adequate procedures and training were in place for plant operators to mitigate the consequences of an SSE.
GIP-2 was reviewed and approved by the staff in Reference 2.
GlP-2 described the use of operator action as a means of accomplishing those activities required to achieve safe shutdown. Section 3.2.7, " Operator Action Permitted," states, in part, that " Timely operator action is permitted as a means of achieving and maintaining a safe shutdown condition provided procedures are available and the operators are trained I
in their use." Additionally, Section 3.2.6, " Single Equipment Failure," states that manual operator action of equipment which is normally power operated is permitted as a backup operation provided that sufficient manpower, time, and procedures are available.
}
Section 3.2.8, " Procedures," states, in part, that " Procedures should be in place for operating the selected equipment for safe shutdown and operators should be trained in
)
their use. It is not necessary to develop new procedures specifically to address the USl i
A-46 program."
I l
in Section 3.7, "Opercions Department Review of SSEL " of GIP-2, the SQUG also described three methods for accomplishing the operations department reviews of the SSEL against the plant operating procedures. Licensees were to decide which method
)
or combination of methods were to be used for their plant-specific reviews. These methods included:
1.
a " desk-top" review of applicable normal and emergency operating procedures, 2.
use of a simulator to model the expected transient, and 3.
performing a limited control room and localin-plant walk-down of actions required by plant procedures.
The staffs evaluation of the SQUG approach for the identification and evaluation of the safe shutdown equipment list, including the use of operator actions, was provided in i
J
r
~
9 Section 11.3 of the staff's SSER (Reference 2). The evaluation concluded that the SQUG approach was acceptable.
As a result of its review of the licensee's A-46 program implementation (Reference 5),
the staff requested additionalinformation regarding operator actions specified in the licensee's report in a letter dated May 16,1996 (Reference 10). By letter dated August 15,1996 (Reference 11), the licensee provided the staff with a response to the RAl.
The staff's review focused on verifying that the licensee had used one or more of the GIP-2 methods for conducting the operations department review of the SSEL, and had considered aspects of human performance in determining what operator actions could be used to achieve and maintain safe shutdown (e.g., resetting relays, manual operation of plant equipment).
The licensee provided information which outlined the use of the " desk-top" evaluation method by a licensed senior reactor operator to verify that existing normal, abnormal and emergency operating procedures were adequate to mitigate the postulated transient and that operators could place and maintain the plant in a safe shutdown condition. The staff verified that the licensee had considered its operator training programs and verified that its training was sufficient to ensure that those actions specified in the procedures could be accomplished by the operating crews. In addition, the staff requested verification that the licensee had adequately evaluated potential challenges to operators, such as lost or diminished lighting, harsh environmental conditions, potential for damaged equipment interfering with the operator's tasks, and th'.i potential for placing an operator in unfamiliar or inhospitable surroundings. The licensee provided information regarding its seismic interaction evaluations and " desk-top" evaluations to substantiate that operator actions could be accomplished in a timeframe required to mitigate the transient.
The staff has completed its review of the human factors aspects of the licensee's submittal regarding the verification of seismic adequacy of mechanical and electrical equipment in operating reactors. The licensee has provided the staff with sufficient information to demonstrate its conformance to the methodology outli ;d in SQUG GIP-2 and is, therefore, acceptable.
2.9 Outlier Idgntification and Resolutions The licensee identified equipment and relay outliers resulting from the A-46 implementation effort in the summary report. A detailed description of each equipment outlier condition was provided in the OSVS (Appendices E1, F1, F2 anc G of the Seismic Evaluation Report of Reference 5) and summarized in Appendix E2 of the same report.
A detailed description of each relay outlier condition was provided in Section 5.2.3 of the Relay Evaluation Report of Reference 5. The majority of the equipment outliers are related to seismic spatial interaction issues while the relay outliers included the seismically sensitive relays and relays with unknown makes and models or with unknown seismic capacities. The outlier documentation included identification of the affected component, description of the associated defects or inadequacies, and proposed method of outlier resolution (e.g., modifications and/or replacement for outliers). In Reference 5,
l e
10 the licensee stated that it will dispose of all outliers before the end of Spring 1998. The licensee also stated that all outliers were reviewed to determine compliance with BSEP seismic licensing / design criteria. All were found to be in compliance and, therefore, none werejudged to present a significant impact on the health and safety of the public. In Reference 8, the licensee indicated that final outlier resolution for certain Unit 2 components associated with the Control Building Heating Ventilation and Air Conditioning system would ndt be completed by the end of Refueling Outage 11 for Unit 1.
In its submittal of September 11,1998 (Reference 9), the licensee indicated that it has completed the outlier resolution for both BSEP, Units 1 and 2 and the results are 4
documented as part of the A-46 design calculation records. In Reference 9, the licensee provided a table containing a breakdown of outliers resolved by calculations, outliers resolved by physical modifications, and outliers resolved by a combination of calculations and physical modifications. The table contains outlier numbers, equipment numbers identified in the SEWS, problem description of the outlier, identification of calculations associated with resolution, and descriptions of resolutions. The staff reviewed the table and found it to be informative and acceptable.
Based on a review of the above information, the staff determined that the licensee's completed actions for resolution of outiiers are reasonable and acceptable.
3.0
SUMMARY
OF STAFF FINDINGS The staffs review of the licensee's USI A-46 implementation program, as provided for each area discussed above, did not identify any significant or programmatic deviation from the GIP-2 methodology regarding the walkdown and the seismic adequacy evaluations at BSEP.
4.0 CONCLUSION
in general, the licensee conducted the USl A-46 implementation in accordance with GIP-
- 2. The licensee's submittal on the USl A-46 implementation indicated that all the safe shutdown equipment included in References 5 and 6 were examined during walkdowns to verify their seismic adequacy. Numerous equipment containing relays were classified as outliers and were included in Attachments E1, F1, F2, and G as well as Section 5.2.3 of Reference 5. The licensee's implementation program did not identify any instance where the operability of a particular system or component was questionable. In Reference 9, the licensee indicated that it has completed all the outlier resolutions. As described in Section 3.0, the staffs review did not identify any areas where the licensee's program deviated from GIP-2 and the staffs SSER No. 2 on SQUG/ GIP-2 issued in
~ 1992.
The staff concludes that the licensee's USl A-46 implementation program has, in general, met the purpose and intent of the criteria in GIP-2 and the staffs SSER No. 2 for the resolution of USI A-46. The staff has determined that the licensee's corrective actions and completed physical modifications for resolution of outliers will result in safety enhancements which, in certain aspects, are beyond the original licensing basis. As a
I1 result, the licensee's actions provide sufficient basis to close the USl A-46 review at the facility. The staff also concludes that the licensee's implementation program to resolve USl A-46 at the facility has adequately addressed the purpose of the 10 CFR 50.54(f) request. Licensee activities related to the USl A-46 implementation may be subject to NRC inspection.
Regarding future use of GlP-2 in licensing activities, the licensee may revise its licensing basis in accordance with the guidance in Section 1.2.3 of the staffs SSER No. 2 on SQUG/ GIP-2, and the staffs letter to SQUG's Chairman, Mr. Neil Smith on June 19, 1998. Where plants have specific commitments in the licensing basis with respect to i
seismic qualification, these ~ commitments should be carefully considered. The overal!
cumulative effect of the incorporation of the GIP-2 methodology, considered as a whole, should be assessed in making a determination under 10 CFR 50.59. An overall conclusion that no unresolved safety question (USO) is involved is acceptable so long as any changes in specific commitments in the licensing basis have been thoroughly evaluated in reaching the overall conclusion. If the overall cumulative assessment leads a licensee to conclude a USQ is involved, incorporation of the GIP-2 methodology into the licensing basis would require the licensee to seek an amendment under the provisions of 10 CFR 50.59.
Principal Contributors:
Y. C. Li J.Ma i
G. Galletti K. Desai Date: August 5, 1999
P T
- p
- ~..
3 s
5.0,
REFER.RLCES._
1.
. Genenc Impigmentation Precedure (GIP) for Seismic Verification of Nuclear Power Plant Equipment," Revision 2, corrected February 14,1992, Seismic Qualification Utility Group 2.
' " Supplemental Safety Evaluation Report No. 2 on Seismic Qualification Utiti:y Group's Generic implementaticn Procedure, Revision 2, corrected February 14,1992,"
May 22,1992 l
' 3.
Letter, CP&L to NRC Document Centrol Desk, " Response to Supplement No.1 to Generic Letter 87-02, SQUG Resolution of USl A-46," dated September 19,1992 4.
Letter, NRC to CP&L " Evaluation of the Brunswick Steam Electric Plant,120-Day Response to Supplement No.1 to Generic Letter 87-02," dated November 23.1992 5.
. Letter, CP&L to NRC Document Control Desk, " Generic Letter 87-02, USl A-46 l
-Walkdown Surnmary Report for Brunswick Steam Electric Plant, Unit Nos.1 and 2,"
daied September 15,1995 6~
Letter, CP&L to NRC Document ControfDesk, " Response to Request for Additional Information on the Resolution of Unresolved Safety issue A 46 at Brunswick Steam Electric Plant, Unit Nos.1 and 2," dated June 17,1997 7.:
Letter, NRC to CP&L', " Request for Additionalinformation on the Resolution of Unresolved Safety issua A-46, Brunswick Steam Electric Plant, Unit Nos.1 and 2," dated March 12,1997 8.
Letter, CP&L to NRC Document Control Desk," Revision to Schedule for Resolution of USI A-46 at Brunswick Steam Electric Plant Unit No. 2," dated July 11,1997
]
- 9. -
Letter, CP&L to NRC Document Control Desk, " Inform that Utility Completed Final OutI;er Resolution for BSEP, Units 1&2 in Response to GL 87-02 re USI A-46," dated September 11, 1998 j
10.
Letter, NRC to'CP&L, " Request for Additional Information on the Resolution of Unresolved
' Safety loue A-46 Brunswick Steam Electric Plant, Unit Nos.1 and 2," dated May 16,1996
- 11.
Letter, CP&L to NRC Document Control Desk, " Response to Request for Additional Information on the Resolution of Unresolved Safety issue A-46, Brunswick Steam Electric
' Plant, Unit Nos.1 and 2," dated August 15,1996 e
p 't m Therefore, we consider GL 87-02 closed for your facility. However, activities related to the A-46 implementation are subject to NRC inspection. If you have any questions regarding this matter, please contact me at 301-415-1390.
Sincerely, Original signed bY:
Allen Hansen, Project Manager, Section 2 Project Directorate ll Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-325 and 50-324
Enclosure:
Safety Evaluation cc w/ encl: See next page Distribution:
Docket File OGC PUBLIC ACRS PDil Rdg.
B. Bonser, Ril E. Dunnington Y.C.Li A. Hansen J.Ma S. Peterson G. Galletti R. Scholl(eMail SE) K. Desai DOCUMENT NAME:G:\\PDil-2\\ Brunswick \\M69433.se.wpd LA:PDil-2_ _
PM:PDil-2, EMCB SRXB SQ;PDJI-2 EDunnin$NnAHansenM bbsh KWichman*
RCaruso*
8/y/99 7/[ /99 3/3/99 6/3/99
/
T / % /99 OFFICIAL RECORD COPY s
(c.
x.