ML19341A083

From kanterella
Jump to navigation Jump to search
Responds to NRC 801125 Ltr Re Violations Noted in IE Insp Repts 50-566/80-17 & 50-567/80-17.Corrective Actions:Part Ii,Section 5.1 of Div of Nuclear Power Operational QA Manual Rewritten
ML19341A083
Person / Time
Site: Yellow Creek  Tennessee Valley Authority icon.png
Issue date: 12/23/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19341A081 List:
References
NUDOCS 8101220058
Download: ML19341A083 (2)


Text

&

, O l's 6 a I s -

r3,~ TENNESSEE VALLEY AUTMCRITY cs ATTA.Nces A. Tzssrss:: 27 :01 $ %, E E l

400 Chestnut Street Tower II December 23, 1980] [ r g 3 p g ,. 4 g Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, 3eorgia 30303

Dear Mr. O'Reilly:

YELLOW' CREEK NUCLEAR PLANT UNITS 1 AND 2 - NRC-OIE REGION II LETTER RII:JLC 50-566/80-17 AND 50-567/80 INSPECTION REPORT - RESPONSE TO DEFICIENCY The subject letter dated November 25, 1980, cited TVA with one deficiency in accordance with 10 CFR 2.201. Enclosed is our response.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 857-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY

, L. M. Mills, Fanager Nuclear Regulation and Safety Enclosure cc: Mr. Victor Stello, Jr., Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 I

N

3101 ~

an e=a amun s,s er

-..- ~ _.------------.. \

.?$h. .

e ENCLOSURE YELLOW CREEK NUCLEAR PLANT UNITS 1 AND 2 RESPONSE TO DEFICIENCY FAILURE TO ESTABLISH RESPONSIBILITIES FOR PRESERVICE INSPECTION WHEN INSPECTIONS ARE CONDUCTED IN VENDOR SHOPS Deficiency 50-566/80-17-01, 50-567/80-17-05 As required by Criterion I of Appendix B to 10 CFR 50, and as implemented by Tennessee Valley Authority (TVA) accepted Quality Assurance Program (Topical Report TVA-TR-75-1A) which imposes ANSI Standard N45.2 dated 1971 states in part, "The organizational structure, functional responsibilities, levels of authority and lines of internal and external communication for management, direction and execution of the quality assurance program shall be documented. Where multiple organizational arrangements exist, the responsibility of each organization shall be clearly established. The authority and responsibility of persons and organizations performing activities affecting quality shall be clearly established."

Contrary to the above, TVA's Division of Power Production Operational Quality Assurance Manual is not clearly applicable for Preservice Inspection when this inspection is performed in the vendor shops.

Activities such as procedure approval, program surveillance, and final report review being performed by the Preservice and Inservice Inspection Section are not clearly defined.

Corrective Action Taken and Results Achieved TVA has rewritten Part II, Section 5.1 of the Division of Nuclear Power Operational Quality Assurance Manual. This rewrite better addresses preservice inspection when this inspection is performed at the vendor's shops.

Corrective Steps Which Will Be Taken to Avoid Further Noncompliance The changes made in the manual should prevent further recurrence of the subject deficiency.

Date When Full Compliance Will Be Achieved The changes should be incorporated into the Division of Nuclear Power Operational Quality Assurance Manual by February 28, 1981.

l l

_ _ _ . _ _ _ _ _ . _ _ _ _ _ . _ _ . _ _ _ _ _ _