TENNESSEE VALLEY AUTHORITY ch-tTitramasaowesc1I July 9, 1980 Mr. James P. O'Reilly, Directo'r Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

, j YELLOW CREEK NUCLEAR PLANT UNITS 1 AND 2 - CONSTRUCTION QA AUDIT -

SIGNIFICANT DEFICIENCIES - YC-C-80 SECOND INTERIM REPORT ,

The subject deficiency was initially reported to NRC-0IE Inspector i M. Thomac on April 21, 1980, l'n accordance with 10 CFR 50.55(c). A first interia report was submitted on May 21, 1980. Enclosed is our second interim report. We expect to submit our next report by August 20, 1980.

i The enclosed report describea ,the final resolution for items 1 and 3 l of Construction QA Audit Deficiency, YC-C-80-03.

If you have any questions conc,arning this matter, please get in touch with D. L. Lambert at FTS 857-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure ec: Mr. Victor Stello, Jr., D'irector (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 30I7 S l i

l t .

/0 i fan Opportunity Employer l

80071 e o qj

-_ _