Text
.
- V TENNESSEE VALLEY AUTHORITY CH ATTANOOGA, TENNESSEE 374C1 400 Chestnut Street Tower II May 21, 1980 Mr. James P.
'Reilly, Director Office of Inspe ion and Enforcement U.S. Nuclear Regu tory Commission Region II - Suite 00 101 Marietta Street Atlanta, Georgia 3030
Dear Mr. O'Reilly:
YELLOW CREEK NUCLEAR PLANT UNITS 1 AND 2 - CONSTRUCTION QA AUDIT -
SIGNIFICAXI DEFICIENCIES - NCR YC-C-80 FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector M. Thomas on April 21, 1980, in accordance with 10 CFR 50.55(e).
Enclosed is our first interim report. We expect to submit our next report by July 9, 1980.
If you have any questions concerning this matter, please get in touch with D. L. Lambert i4-2581.
Very truly yours, TENNESSEE VALLEY AUTliORITY
^
L. M. Mills, Manager Nuclear Regulation and Safety Enclosure cc:
Mr. Victor Stallo, Jr., Director (Enclosure)
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission l
Washington, DC 20555
%\\
8005280 69/
An Ecual Ooportumty Emoleyer