LER 80-004/03L-0:on 800109,during Test of Equipment Hatch Emergency Escape Lock,Inner Door Seal Found Leaking When Door Opened & Lock Found to Be Under Slight Vacuum.Caused by Frequent Door Operation.Seals Replaced
ML19260D566
Person / Time
Site: North Anna Dominion icon.png
Issue date: 02/08/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19260D565 List:
References
LER-80-004-03L, LER-80-4-3L, NUDOCS 8002110425
Download: ML19260D566 (2)


Text

NRC FORM 366 U. S. NUCLEAR REGULATORY COMMISSION (7 U)

LICENSEE EVENT REPORT CONTROL BLOCK: l l l l l l (PLEASE PRINT OR TYPC ALL REQUIRED INFORMATION) io l iH i9 i vi Al 7

N Al st 11el ol 01 -1 LICENSEE CODE 14 lb o o 4 o d -1 d del a il it i 31el LICEN5k NUYHtH 24 26 LICENSE TYPE 30 I

SI C A I Sd le CON'T o 1 3

g[gf l b h}  !

] 3 ] _ dhj Q )) d4 fj dhl d d d d pl plh u 63 EVENT DATE 14 15 HEPORT DATE E3 7 6 60 61 OOGafNUMetR EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h o 2 l During testing of the equipment hatch emergency escane lock _ the innor anne co,1 mc I o a discovered leaking when the door was opened and the lock was found to be isndor n I o 4 l slight vacuuo. The outer door also exhibited excessive leakace durino mih no oit an *  !

o s I testing of door seals. The health and safety of the general public were not nfforrod 1 0 6 l by this event. Reportable pursuant to T.S. 6.9.1.9.b and c .

o I i l I

O a l SYSTE M CAUSE CAUSE COMP. VALVE CODE CODE SL8 CODE COVPON ENT CODE SUSCODE SUBCODE o 9 l Xl Xl@ [D j@ l Zl@ l Pl El Nl El Tl Rlh Wh l 7l h 7 8 9 10 1I_ 12 13 18 19 20 REVISION

,.,. SEOUEN TI AL OCCURRENCE REPORT EVENTVEAR REPORT NO. CODE TYPE No.

LER

@ ayg/RO I 81 01 1-1 1 01 01 4 l ]/] l 4 3] lJu Li L-J LIJ 32

_ 21 22 23 24 26 27 28 29 31 ACTION FilTU R E EFFECT SHUTDOWN ATT ACHV E N T NPR O-4 PRIVE COMP. COMPONENT TAKEN ACTION ON PLANT P.iE TH OD HOURS SUHYlTTED FORMhuB. SUPP LI E R MANUFACTURER I

33 E

34 G

35

[Z lg 36 l0 l0 31 0 l 40

{@

41 lN 42 l@ [A_j@

43 lC 44 l3 11 1047l@

CAUS. ,ESCRIPTION AND CORRECTIVE ACTIONS h i o l It is believed that the inner door leaked because the door was previous 1v disturbed 1

, , when someone attempted to open the door with strongback on and the outer door no,1 1

, , y1 caked due to frequent operation when working on the inner door. The inner door j

,, ,,, g gasket was cleaned and reinstalled and the gasket for the outer door was replaced . I

,, ,,, g oth B doors were then properly adjusted and the seals were retested with satisfactory I

, , 9 tesuus. 80 C Y

's^TlNTS  % POWER oTHER STATUS DISCO RY DISCOVER ' OESCRIPTION l s d@ l 0l 0l Ojgl NA l lDl@l 46 Surveillgce Teq 80 l

, 8 3 10 12 13 44 45 ACTIVITY CONTENT REL ASEO OERELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE i e NA l K,1 l F 8 9 L_l @ l10 zi@i 11 44 45 ,,

PERSONNEL E XPOSUAES 8ER TYPE DESCRIPTION NU"0 y

i 7 8 9 1 1 1 11 l@lZl@l 12 13 m

,p3 j 1

() 80 PERSONNE L INJUHIES  ; ,

9ER D ESCRt P riON I

li la l 101NU"0 IU l@l

'I LOSS OF OR O TYPE AGE TO FACILITV D E SC RIP TION 3 80 023 70p n ' I y

, 2 a 9 i zi@l to 80 PURLICITY NRC USE ONLY ,

g El D@ n DESCRIPTION i l11ll11 Iil1g4 2 o ISSU I 69 69 80 5 7 8 9 10

?

NAVE OF PAEPARER " N -t ~ i ;? ! PHONE '3 3_;,,_;;3; 3

Virginia Electric and Power Company North Anna Power Stat su, Unit #1 At tachme n t , Page 1 of 1 Docke t No. 50-338 Report No. LER 80-004/03L-0 Description of Event During required testing to verify containment integrity, the outer door of the equipment hatch escape lock was opened by mistake. When the door was opened, the lock was found to be under a slight vacuum which gave indication that the inner door seal was leaking. Subsequent testing of the escape lock door seals revealed that the inner door seal was, in fact, leaking and that the outer door seal was leaking as well.

Prcbable Consequences of Occurrence The consequences of this event were limited because when the leakage was discovered, the unit was in Mode 4 and prior to that time had been shutdown for refueling. The effects were also minimized because the integrity of the containment was restored within the time limit allowed by the Action Statement of T.S. 3. 6.1.1. As a result, the health and safety of the general public were not affected by this event. There are no generic implications associated with this occurrence.

Cause of Event It is believed that the inner door seal was previously disturbed when someone inadvertently attempted to open the door with the strongback on. The leakage of the outer door seal was attributed to traffic through the door when working on che inner coor. Investigation of this event revealed that *he door seals were not testei af ter entry into the emergency hatch to remove the strongback from the inner door.

Immediate Corrective Action The gasket for the inner door was removed , cleaned and reinstalled. The outer door gasket was replaced with a new set. Both doors were then properly adjusted and the seals were retested with acceptable results.

Scheduled Corrective Action No scheduled corrective action is required.

Actions Taken to Prevent Recurrence A program will be developed to ensure the correct sequence of future testing o' the escape lock.