r e
e VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 W. L. STEWART VICE PRESIDENT NucLE..u< OPERATIONS August 24, 1984 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:
Mr. D. G. Eisenhut, Director Division of Licensing U.S. Nuclear Regulatory Commission Washington, D. C.
20555 Gentlemen:
Serial No. 376A PSE/NAS:vdu Docket Nos. :
50-280 50-281 50-338 50-339 DPR-32 DPR-37 NPF-4 NPF-7 License Nos.:
. VEPCO REACTOR SYSTEM TRANSIENT ANALYSES Attachments 1 through 3 provide supplemental information related to our Topical Report VEP-FRD-41, 11 Vepco Reactor System Transient Analysis Using the RETRAN Computer Code 11
, transmitted by our letter to you of April 14, 1981, Serial No. 215.
Mr. James L. Carter of the Division of Systems Integration informally provided us with a request for additional information which would be required to complete a review of VEP-FRD-41 by the NRC staff.
Portions of this requested information were provided in earlier submittals (Serial No. 060, dated February 27, 1984 and Serial Number 376, dated July 12, 1984).
Attachments 1 through 3 provide the balance of the requested information.
Specifically, Attachment 1 provides a description and qualification informa-tion for our RETRAN control system models.
The results of comparisons of RETRAN calculations to calculations performed with LOFTRAN, a code developed by Westinghouse Electric Corporation, are provided in Attachments 2 (Proprietary) and 3 (Non-Proprietary).
As Attachment 2 contains information proprietary to Westinghouse Elec-tric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information (see Attachment 4).
The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in para-graph (b)(4) of Section 2.790 of the Commission 1s regulations.
-- -----~-------~
8409060272 840824 PDR ADOCK 05000280 P
e vrnoINIA ELECTRIC AND PowER CoMPANY To Mr. Haro 1 d R. Denton Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission 1s regulations.
Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse affidavit should reference CAW-84-58 and should be addressed to_R. A. Wiesemann, Manager, Regulatory and Legislative Affairs, Westinghouse Electric Corporation, P. 0. Box 355, Pittsburgh, PA 15230.
As we have discussed previously with your staff, we will be happy to meet at any time to discuss the Topical Report and our use of RETRAN in order to assist you in completing your review by your target date of January 15, 1985.
Attachments cc:
Mr. D. H. Moran Standardization and Special Projects Br,anch Mr. J. L. Carter Reactors Systems Branch Mr. James P. 0 1Reilly Regional Administrator Region II Mr. James R. Miller, Chief Operating Reactors Branch No. 3 Division of Licensing Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing Mr. D.. J. Burke NRC Resident Inspector Surry Power Station Mr. M. W. Branch NRC Resident Inspector North Anna Power Station Very truly yours, W. L. Stewart