ML18012A305
| ML18012A305 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 01/12/2018 |
| From: | John Lamb Special Projects and Process Branch |
| To: | David Helker Exelon Corp |
| References | |
| L-2017-LLR-0156 | |
| Download: ML18012A305 (2) | |
Text
1 NRR-DMPSPEm Resource From:
Lamb, John Sent:
Friday, January 12, 2018 10:28 AM To:
'david.helker@exeloncorp.com' Cc:
Richard.Gropp@exeloncorp.com; 'David.Distel@exeloncorp.com'
Subject:
Acceptance Review - Oyster Creek - Relief Request - Relief Request for Extension of Torus Examinations in accordance with 10 CFR 50.55a(z)(1) (EPID: L-2017-LLR-0156)
Importance:
High
Dear Mr. Helker:
By letter dated December 19, 2017 (ML17353A008), Exelon Generation Company, LLC submitted a relief request for Oyster Creek Nuclear Generating Station. The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this relief request (EPID: L-2017-LLR-0156). The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed relief request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.
Based on the information provided in your submittal, the NRC staff has estimated that this licensing request will take approximately 425 hours0.00492 days <br />0.118 hours <br />7.027116e-4 weeks <br />1.617125e-4 months <br /> to complete. The NRC staff expects to complete this review in approximately 7 months, which is July 2018. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes in the forecasted hours, the reasons for the changes, along with the new estimates, will be communicated during the routine interactions with the assigned project manager.
These estimates are based on the NRC staffs initial review of the application and they could change, due to several factors including requests for additional information, unanticipated addition of scope to the review, and review by NRC advisory committees or hearing-related activities. Additional delay may occur if the submittal is provided to the NRC in advance or in parallel with industry program initiatives or pilot applications.
If you have any questions, please contact me.
John G. Lamb, Senior Project Manager Special Projects and Process Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Hearing Identifier:
NRR_DMPS Email Number:
91 Mail Envelope Properties (John.Lamb@nrc.gov20180112102800)
Subject:
Acceptance Review - Oyster Creek - Relief Request - Relief Request for Extension of Torus Examinations in accordance with 10 CFR 50.55a(z)(1) (EPID: L-2017-LLR-0156)
Sent Date:
1/12/2018 10:28:11 AM Received Date:
1/12/2018 10:28:00 AM From:
Lamb, John Created By:
John.Lamb@nrc.gov Recipients:
"Richard.Gropp@exeloncorp.com" <Richard.Gropp@exeloncorp.com>
Tracking Status: None
"'David.Distel@exeloncorp.com'" <David.Distel@exeloncorp.com>
Tracking Status: None
"'david.helker@exeloncorp.com'" <david.helker@exeloncorp.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 2743 1/12/2018 10:28:00 AM Options Priority:
High Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: