UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555*0001 October 4, 2011 APPLICANT: Energy Northwest FACILITY:

Columbia Generating Station

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON SEPTEMBER 29, 2011, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENERGY NORTHWEST, CONCERNING THE INSPECTION REPORT PERTAINING TO THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION (TAC NO. ME3058)

The U.S. Nuclear Regulatory Commission and representatives of Energy Northwest (the applicant), held a telephone conference call on September 29, 2011, to discuss and clarify the inspection report concerning the Columbia Generating Station, license renewal application. provides a listing of the participants and Enclosure 2 contains the topic discussed with the applicant, including a brief description on the status of the item.

The applicant had an opportunity to comment on this summary.

Arthur D. Cunanan, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-397

Enclosures:

As stated cc w/encls: Listserv

TELEPHONE CONFERENCE CALL COLUMBIA GENERATING STATION LICENSE RENEWAL APPLICATION PARTICIPANTS:

Arthur Cunanan Aloysius Obodoako Abbas Mostala Scott Wood Karen Clark Elisa Nguyen Jeff Scott LIST OF PARTICIPANTS September 29, 2011 AFFILIATIONS:

U.S. Nuclear Regulatory Commission (NRC)

NRC Energy Northwest (EN)

EN EN EN EN ENCLOSURE 1

TELEPHONE CONFERENCE CALL COLUMBIA GENERATING STATION LICENSE RENEWAL APPLICATION SEPTEMBER 29, 2011 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Energy Northwest (the applicant), held telephone conference calls on September 29, 2011, to discuss the inspection report concerning the Columbia Generating Station license renewal application.

LRA Section B.2.36, "Lubricating Oil Analysis Program" Discussion:

The applicant discussed how the license renewal inspection report stated that the applicant had not effectively implemented actions in response to industry operating experience related to silver content in the diesel generator lubricating oil.

The applicant stated corrective actions were implemented and resolved by requiring all emergency diesel generators to undergo the low silver test methodology; however, the applicant will not include the low silver test methodology into the Lubricating Oil Analysis Aging Management Program because the low silver test detects silver contents from the piston which is an active component.

The applicant does test for particulates in its Lubricating Oil Analysis Aging Management Program which includes silver as a particulate; however, the test does not distinguish between silver and other particulates. If the particulate test determines that particulates are out of specifications, the applicant will perform corrective actions.

The staff understands the applicant's statement and will not send a request for additional information.

ENCLOSURE 2

October 4, 2011 APPLICANT: Energy Northwest FACILITY:

Columbia Generating Station

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON SEPTEMBER 29,2011, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENERGY NORTHWEST, CONCERNING THE INSPECTION REPORT PERTAINING TO THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION (TAC NO. ME3058)

The U.S. Nuclear Regulatory Commission and representatives of Energy Northwest (the applicant), held a telephone conference call on September 29, 2011, to discuss and clarify the inspection report concerning the Columbia Generating Station, license renewal application. provides a listing of the participants and Enclosure 2 contains the topic discussed with the applicant, including a brief description on the status of the item.

The applicant had an opportunity to comment on this summary.

IRA!

Arthur D. Cunanan, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-397

Enclosures:

As stated cc wfencls: Listserv DISTRIBUTION:

See next page ADAMS Accession No'.. ML11273A066

  • concurrence via e-mail OFFICE LA: DLR/RPB1*

PM: DLR/RPB1 BC: DLR/RPB1 PM: DLR/RPB1 NAME SFigueroa ACunanan DMorey ACunanan DATE 9/30/2011 9/30/11 10/2/11 10/4/11 OFFICIAL RECORD COpy

Letter to Energy Northwest from Arthur D. Cunanan dated October 4, 2011

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON SEPTEMBER 29,2011, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENERGY NORTHWEST, CONCERNING THE INSPECTION REPORT PERTAINING TO THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION (TAC NO. ME3058)

DISTRIBUTION:

HARDCOPY:

DLR R/F E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRapb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource ACunanan DDoyle DMorey MThadani WWalker, RIV RCohen, RIV LSubin,OGC BSingal