ML11272A124

From kanterella
Jump to navigation Jump to search

Request for Additional Information for the Review of Columbia Generating Station, License Renewal Application Regarding Operating Experience
ML11272A124
Person / Time
Site: Columbia 
Issue date: 09/30/2011
From: Cunanan A
License Renewal Projects Branch 1
To: Swank D
Energy Northwest
Cunanan A
References
TAC ME3058
Download: ML11272A124 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 30, 2011 Mr. David A. Swank, Vice President of Engineering Columbia Generating Station Energy Northwest MD PE23 P.O. Box 968 Richland, WA 99352

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION REGARDING OPERATING EXPERIENCE (TAC NO. ME3058)

Dear Mr. Swank:

By letter dated January 19, 2010, Energy Northwest submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54, to renew operating license NPF-21 for Columbia Generating Station, for review by the U.S. Nuclear Regulatory Commission (NRC or the staff). The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review. Further requests for additional information may be issued in the future.

Items in the enclosure were discussed with Abbas Mostala and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-3897 or bye-mail at arthur.cunanan@nrc.gov.

Sincerely, Arthur D. Cunanan, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-397

Enclosure:

As stated cc w/encl: Listserv

COLUMBIA GENERATING STATION LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION RAt 8.1.4-2

Background

In request for additional information (RAI) B.1.4-1 issued on May 24. 2011. the staff asked the applicant to describe the programmatic activities that will be used to continually identify aging issues. evaluate them and. as necessary. enhance the aging management programs (AMPs) or develop new AMPs for license renewal. In its response dated June 23. 2011. and later revised in a letter dated July 11. 2011. the applicant stated that it will use its current corrective action program (CAP) and operating experience program (OEP) to continually monitor and evaluate plant-specific and industry operating experience related to aging.

In its response. as revised. the applicant provided a general description of the processes used to evaluate operating experience on an ongoing basis; however. the applicant did not provide specifics on how aging-related issues are addressed under these processes. Specifically. the applicant did not address the following items:

(a) The applicant did not describe a means for identifying and categorizing operating experience items as related to aging.

(b) The applicant did not describe how evaluations of operating experience items related to aging consider the fundamental components of an aging management review. which are the following:

systems. structures. or components materials environments aging effects aging mechanisms AMP(s)

(c) The applicant did not describe training requirements specific to aging issues for those plant personnel responsible for screening, evaluating. and submitting operating experience items.

(d) The applicant did not describe how it will consider as operating experience the results of the AMP inspections.

ENCLOSURE

2 (e) The applicant stated that it does not consider certain guidance documents to be sources of operating experience. However, the staff believes that the content of the document, not the source, is the most important consideration. Guidance documents, such as NUREG-1801, "Generic Aging Lessons Learned (GALL) Report," provide a convenient source of operating experience information, useful recommendations, and best practices. As such, the staff believes there is significant value in considering new guidance applicable to aging management. An effective operating experience program should include a broad range of inputs and, therefore, it is inappropriate to exclude consideration of specific issues in guidance documents.

(f) The applicant stated that, under the OEP, supervisors are responsible for ensuring the timely completion of operating experience evaluations; however, the applicant provided no additional detail on what constitutes a timely evaluation.

Request Respond to each item below for both the CAP and OEP:

(a) Describe how operating experience issues will be identified and categorized as related to aging.

(b) Describe how evaluations of operating experience issues related to aging will consider the following:

  • systems, structures, or components
  • materials
  • environments
  • aging effects
  • aging mechanisms

(c) Describe the training requirements on aging issues for those plant personnel responsible for screening, evaluating, and submitting operating experience items.

(d) Describe how the results of the AMP inspections will be reviewed.

(e) Provide a plan for conSidering the content of guidance documents, such as the GALL Report, as operating experience applicable to aging management programs.

(f) Describe what constitutes a timely evaluation under the OEP.

ML11272A124

  • concurrence via e-mail OFFICE LA: DLR/RPB1 PM: DLR/RPB1 BC: DLR/RPB1 LA: DLR/RPB1 PM: DLR/RPB1 NAME SFigueroa 29/2011 ACunanan 9129/2011 DMorey 11 SFigueroa 9/29/2011 ACunanan 9/30111

Letter to David A. Swank from Arthur D. Cunanan dated September 30,2011

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION REGARDING OPERATING EXPERIENCE (TAC NO. ME3058)

DISTRIBUTION:

HARD COPY:

DLR R/F E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRapb Resource RidsNrrDIrRasb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource ACunanan DDoyie DMorey MThadani WWalker, RIV RCohen, RIV LSubin,OGC BSingal