Clarification Requested (Ihpb) Extended Power Uprate License Amendment Request
ML102440139
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 08/26/2010
From: Beltz T
Plant Licensing Branch III
To: Hale S
Point Beach
beltz T, NRR/DORL/LPL3-1, 301-415-3049
References
TAC ME1044, TAC ME1045
Download: ML102440139 (2)


Text

From:

Beltz, Terry Sent:

Thursday, August 26, 2010 10:34 AM To:

'Hale, Steve' Cc:

'COSTEDIO, JAMES'; 'Flentje, Fritzie'; 'liz.abbott@fpl.com'; 'Hanneman, Harv'

Subject:

Point Beach Nuclear Plant, Units 1 and 2 - Clarification Requested (IHPB) re:

Extended Power Uprate License Amendment Request (TAC Nos. ME1044 and ME1045)

Dear Mr. Hale As we discussed during a phone call on August 25, 2010, the NRC technical staff in the Health Physics and Human Performance Branch (IHPB) of the Office of Nuclear Reactor Regulation (NRR) has requested further information related to the August 23, 2010, NextEra Energy Point Beach, LLC (NextEra) response to requests for additional information (RAI) (ADAMS Accession No. ML102370315).

The NRC staff requires additional detailed information associated with RAI response IHPB-4.

Specifically, the response provided documentation indicating that the NRC has accepted evacuation in lieu of meeting the habitability requirements of NUREG 0737 II.B.2, and NextEra referenced a 1981 submittal in response to NRC GL 81-10. The NRC staff requests that NextEra provide both the 1981 submittal and any documentation verifying the NRR review and acceptance, highlighting the issues of TSC habitability and compensatory measures in lieu of meeting II.B.2.

The NRC staff further notes that NRC GL 81-10 provided some additional clarifications on the acceptability of the emergence response facilities (OSC, TSC, and EOF). The GL 81-10 did not address TSC habitability other than to quote TMI Action Item III.A.1 that required that the TSC shall be habitable to the same degree as the control room for postulated accident conditions.

In other words, ensure adequate shielding to meet General Design Criterion 19 (as specified in TMI Action Item II.B.2) for vital areas such as the TSC.

If you have any additional questions, please dont hesitate contacting me.

Sincerely, Terry A. Beltz, Senior Project Manager NRR/ADRO/DORL/LPL3-1 (301) 415-3049 E-mail Properties Mail Envelope Properties (87B1F1BDFE5A554CA9DC5EAA75EB6D0D23116C0681)

Subject:

Point Beach Nuclear Plant, Units 1 and 2 - Clarification Requested (IHPB) re:

Extended Power Uprate License Amendment Request (TAC Nos. ME1044 and ME1045)

Sent Date: 8/26/2010 10:33:36 AM Received Date: 8/26/2010 10:33:00 AM From: Beltz, Terry

Created By: Terry.Beltz@nrc.gov Recipients:

Steve.Hale@nexteraenergy.com ('Hale, Steve')

Tracking Status: None JAMES.COSTEDIO@nexteraenergy.com ('COSTEDIO, JAMES')

Tracking Status: None Fritzie.Flentje@nexteraenergy.com ('Flentje, Fritzie')

Tracking Status: None liz.abbott@fpl.com ('liz.abbott@fpl.com')

Tracking Status: None Harv.Hanneman@nexteraenergy.com ('Hanneman, Harv')

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 11601 8/26/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: