UNITED STATES NUCLEAR REGULATORY COMMISSION ust 21, 2009
SUBJECT:
VC SUMMER NUCLEAR PLANT - NRC OPERATOR LICENSE EXAMINATION REPORT 05000395/2009301
Dear Mr. Archie:
During the period June 30 - July 8, 2009, the Nuclear Regulatory Commission (NRC)
administered operating tests to employees of your company who had applied for licenses to operate the V.C. Summer Nuclear Plant Unit. At the conclusion of the tests, the examiners discussed preliminary findings related to the operating tests and the written examination submittal with those members of your staff identified in the enclosed report. The written examination was administered by your staff on July 10, 2009.
Three RO applicants and five SRO applicants passed both the operating test and written examination. One RO applicant and one SRO applicant passed the operating test but did not pass the written examination. Three RO applicants and three SRO applicants were issued licenses. There were two borderline grades. One SRO applicant passed the operating test, but passed the written examination with an overall score between 80% and 82%. One SRO applicant passed the operating test, but passed the SRO portion of the written examination with a score between 70% and 74%. Because these are borderline grades, their licenses are being held in abeyance pending any examination appeals. There were six post-examination comments. A Simulator Fidelity Report is included in this report as Enclosure 3.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRCs document system (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm.adams.html (the Public Electronic Reading Room).
SCE&G 2 If you have any questions concerning this letter, please contact me at (404) 562-4550.
Sincerely,
/RA/
Malcolm T. Widmann, Chief Operations Branch Division of Reactor Safety Docket No: 50-395 License No: NPF-12
Enclosures:
1. Report Details 2. Facility Post-Examination Comments and NRC Resolutions 3. Simulator Fidelity Report
REGION II==
Docket No.: 50-395 License No.: NPF-12 Report No.: 05000395/2009301 Licensee: South Carolina Electric and Gas Facility: V.C. Summer Location: Jenkinsville, South Carolina Dates: Operating Test - June 30 - July 8, 2009 Written Examination - July 10, 2009 Examiners: Ronald F. Aiello, Chief Examiner, Senior Operations Engineer Bruno L. Caballero, Operations Engineer Michael K. Meeks, Operations Engineer Approved by: Malcolm T. Widmann, Chief Operations Branch Division of Reactor Safety Enclosure 1
SUMMARY OF FINDINGS
ER 05000395/2009301, operating test June 30 - July 8, 2009 & written exam July 10, 2009;
V.C. Summer; Operator License Examinations.
Nuclear Regulatory Commission (NRC) examiners conducted an initial examination in accordance with the guidelines in Revision 9, Supplement 1, of NUREG-1021, "Operator Licensing Examination Standards for Power Reactors." This examination implemented the operator licensing requirements identified in 10 CFR §55.41, §55.43, and §55.45, as applicable.
Members of the V.C. Summer training staff developed both the operating tests and the written examination. The NRC developed the written examination outlines.
The NRC administered the operating tests during the period June 30 - July 8, 2009. Members of the V.C. Summer training staff administered the written examination on July 10, 2009. Three RO applicants and five SRO applicants passed both the operating test and written examination.
One RO applicant and one SRO applicant passed the operating test but did not pass the written examination. Three RO applicants and three SRO applicants were issued licenses. There were two borderline grades. One SRO applicant passed the operating test, but passed the written examination with an overall score between 80% and 82%. One SRO applicant passed the operating test, but passed the SRO portion of the written examination with a score between 70% and 74%.
There were six post-examination comments.
One Licensee-Identified Violation (LIV) of very low safety significance in the area of examination security has been reviewed by the inspectors. Corrective actions taken or planned by the licensee have been entered into the licensees corrective action program. This violation and corrective actions are listed in Section 4OA7 of this report.
REPORT DETAILS
OTHER ACTIVITIES
4OA5 Operator Licensing Examinations
a. Inspection Scope
Members of the V.C. Summer training staff developed both the operating tests and the written examination. The NRC developed the written examination outlines. All examination material was developed in accordance with the guidelines contained in Revision 9, Supplement 1, of NUREG-1021, "Operator Licensing Examination Standards for Power Reactors." The NRC examination team reviewed the proposed examination. Examination changes agreed upon between the NRC and the licensee were made per NUREG-1021 and incorporated into the final version of the examination materials.
The NRC reviewed the licensees examination security measures while preparing and administering the examinations in order to ensure compliance with 10 CFR §55.49, Integrity of examinations and tests. One Licensee-Identified Violation (LIV) of very low safety significance in the area of examination security has been reviewed by the inspectors.
The NRC examiners evaluated four Reactor Operator (RO) and six Senior Reactor Operator (SRO) applicants using the guidelines contained in NUREG-1021. The examiners administered the operating tests during the period June 30 - July 8, 2009.
Members of the V.C. Summer training staff administered the written examination on July 10, 2009. Evaluations of applicants and reviews of associated documentation were performed to determine if the applicants, who applied for licenses to operate the V.C.
Summer Nuclear Plant, met the requirements specified in 10 CFR Part 55, Operators Licenses.
b. Findings
The NRC determined, using NUREG-1021, that the licensees examination submittal was within the range of acceptability expected for a proposed examination.
One Licensee-Identified Violation (LIV) of very low safety significance in the area of examination security has been reviewed by the inspectors. Corrective actions taken or planned by the licensee have been entered into the licensees corrective action program (Condition report (CR) 09-02791). This violation and corrective actions are listed in Section 4OA7 of this report.
Three RO applicants and five SRO applicants passed both the operating test and written examination. One RO applicant and one SRO applicant passed the operating test but did not pass the written examination. Three RO applicants and three SRO applicants were issued licenses. There were two borderline grades. One SRO applicant passed the operating test, but passed the written examination with an overall
score between 80% and 82%. One SRO applicant passed the operating test, but passed the SRO portion of the written examination with a score between 70% and 74%.
These applicants were issued a letter stating that they passed the examination and issuance of their license has been delayed pending any written examination appeals that may impact the licensing decision for their application.
The following operating test concerns were noted:
- The NRC received the final operating test late which caused a one day delay in starting the exam.
- Problems with locks in the training building caused a one hour delay in starting the second day of simulator scenarios.
- On one occasion, a surrogate Shift Technical Engineer informed an applicant SRO that the integrity critical safety function was met, when in actuality there was a red path on integrity and an immediate transition to EOP-16.0 was required.
- Inconsistencies were identified in the area of control room communications and the use of PA announcements.
The following discrepancies were identified:
- Emergency Operating Procedure (EOP) - 4.0,Steam Generator Tube Rupture, Rev. 18, step 18 b) Alternative Action: For the specific case of a steam generator tube rupture coincident with a stuck-open Pressurizer Power Operated Relief Valve (PORV) and PORV block valve, this step directed operators to transition from EOP-4.0 to EOP-4.2, SGTR With Loss Of Reactor Coolant: Subcooled Recovery Desired with a maximum rate Reactor Coolant System (RCS) cool down in progress. The issue with this transition was that EOP-4.2 did not contain procedural guidance to stop the maximum rate cool down at the required temperature determined in EOP-4.0. Instead, the initial 14 steps of EOP-4.2 essentially contained guidance to prepare the plant to commence cooling down; then, step 15 of EPO-4.2 directed operators to Initiate RCS Cooldown to Cold Shutdown: a.
Maintain the cooldown rate in RCS cold legs Less Than 100°F/hr. In a worst-case example, if operators were to transition to EOP-4.2 and continue cooling down at a maximum rate beyond the EOP-4.0 required temperature, an Orange path could be generated in Integrity due to improper operator actions and entry into EOP-16.0, Response To Imminent Pressurized Thermal Shock, would be required to stop the excessive cool down. The procedural deficiency was discovered by the NRC during validation week.
- Alarm Response Procedure (ARP) 614 1-3 (CC Loop A RM-L2A HI RAD): This procedure required placing excess letdown in service before isolating letdown and stopping the leak into the Component Cooling Water (CCW) system. The Abnormal Operating Procedure (AOP) AOP-102.1, Loss Of Letdown, Rev. 2 required isolating letdown first followed by placing excess letdown in service.
- EOP-2.0, Loss of Reactor or Secondary Coolant, Rev. 13: The reference page of this procedure contained different criteria for transitioning to EOP-2.4, Loss of Emergency Coolant Recirculation, Rev. 11, than was used at step 16 in the body of the EOP-2.0. The confusion over the different criteria led one team of applicants to fail to recognize a loss of recirculation condition, and therefore the team failed to transition to EOP-2.4 when that transition was required.
- There was a caution tag on valve HCV-186, INJ flow, that referenced a commitment to isolate air to the valve (and thereby render it non-functional) in Modes 1 and 2.
One alarm response procedure, ARP XCP-644-1-3 CC Loop A RM-L2A HI RAD, did not reflect the correct status of this valve in MODES 1 and 2. Specifically, there was a procedural step in ARP- XCP-644-1-3 that directed the operators to Adjust HCV-186, INJ flow, to maintain 6-13 gpm per Reactor Coolant Pump (RCP) even though the air was isolated to the pneumatic operator. No option is provided to use an alternate means to throttle RCP seal injection flow. One simulator crew verbalized the issue and discussed using operators in the field to throttle RCP seal injection flow; two other crews read the step in the ARP and did not identify any problem with using HCV-186.
All of these items (operating test concerns and procedure discrepancies) as well as several others are being tracked via Condition Report (CR) 09-02791.
Copies of all individual examination reports were sent to the facility Training Manager for evaluation of weaknesses and determination of appropriate remedial training.
The licensee submitted six post-examination comments concerning the written examination. A copy of the final written examination (RO and SRO) and answer keys, with all changes incorporated, and the licensees post-examination comments may be accessed in the ADAMS system (ADAMS Accession Number(s) ML092290932, ML092290946, and ML092260752.
4OA6 Meetings, Including Exit
Exit Meeting Summary
On July 8, 2009, the NRC examination team discussed generic issues associated with the operating test with Jeff Archie, Site Vice President, and members of the V.C.
Summer staff. The examiners asked the licensee if any of the examination material was proprietary. No proprietary information was identified.
4OA7 Licensee Identified Violations
The following violation, of very low safety significance (Green), was identified by the licensee and is a violation of NRC requirements which met the criteria of Section VI of the NRC Enforcement Policy, NUREG-1600, for being dispositioned as a non-cited violation (NCV).
The significance of this event was that four questions were left unsecure in violation of NTM-30.03A, Development, Review, and Validation of Initial Licensing NRC and Audit Examinations, Rev 0, Change B and 10 CFR 55 requirements. On July 9, 2009, the licensee called the NRC at Region II to report that four questions on the RO written examination had been left in the copy machine sorter for a period of approximately 15 -
30 minutes. The Chief Examiner in consultation with the Branch Chief discussed the preliminary information with the licensee and allowed the written examination to proceed with the understanding that it could become invalid if it was determined that the examination had actually been compromised.
The licensee is required by 10 CFR 55.40 (b)(2) to establish, implement, and maintain procedures to control examination security and integrity in accordance with 10 CFR 55.49. Procedure NTM-30.03A requires the person that has control and makes copies to verify that no exam material is left in the copy machine. An inadequate check was made at the copy machine which resulted in four questions of the RO exam being left in the copy machine sorter for less than 30 minutes before being identified by a facility instructor, familiar with the sensitivity of such material, who immediately brought it to the attention of the training department.
The licensee completed its investigation and NRC follow-up occurred during the week of July 27, 2009. The inspector concurred with the licensee's bases for no apparent actual compromise and the inspector noted a very low potential for compromise. The bases was that the four questions of the RO written examination were left in the copier for a short length of time (less than 30 minutes) and other factors, such as copier location and applicant whereabouts during the time in question, were taken into consideration.
This licensee identified finding had a very low safety significance (low potential for compromise) for the bases noted above. The issue has been entered into the corrective action system for resolution (CR- 09-02700). This violation of NRC examination security requirements is being treated as a non-cited violation (NCV 05000395/2009301-01).
KEY POINTS OF CONTACT Licensee personnel J. Archie, Site Vice President L. Blue, Nuclear Training Manager R. Ellis, Operations Training Instructor D. Gatlin, Plant Manager F. Lucas, Operations Supervisor B. Thompson, Nuclear Licensing Manager R. Quick, Supervisor, Development R. Ray, Operations Training Supervisor S. Zarandi, General Manager, Nuclear Support Services NRC personnel J. Zeiler, Senior Resident Inspector
FACILITY POST-EXAMINATION COMMENTS AND NRC RESOLUTIONS
A complete text of the licensees post-examination comments can be found in ADAMS under
Accession Number ML092260752.
Item
RO Question 16, K/A 005K5.02
Licensee Comment
The licensee recommended that the question be deleted since there are no correct answers.
The question asks, based upon conditions stated in the stem, which of the choices describes
the operability of Train A RHR with respect to Technical Specification 3.5.3, ECCS Subsystems
- Tavg < 350°
- F. The licensee contends that for Train A RHR, with respect to Technical Specification 3.5.3, in the cooldown alignment, it is neither Operable nor Inoperable. In
accordance with Technical Specification 3.5.3, ECCS Subsystems - Tavg < 350°F, only one
ECCS subsystem is required to be operable. The stem of the question states Mode 4 was just
entered and Train A RHR was just started in the cooldown mode. There is no information in
the stem regarding re-alignment of Train B RHR or abnormalities associated with Train B
RH
- R. The licensee contends that for the conditions stated, Train B RHR is assumed in its
normal ECCS alignment (and is the Train taken credit for Operability per T.S. 3.5.3). In
accordance with GOP-6 Plant Shutdown From Hot Standby to Cold Shutdown (Mode 3 to Mode
5) and SOP-115, Residual Heat Removal, with RCS temperature greater than 250°F, only one
train of RHR should be in service for heatup or cooldown to ensure RHR injection capability.
Because Train B RHR is still in its ECCS alignment and only one ECCS subsystem is required
to be Operable, the licensee contends that Train A RHR is not applicable to the specification as
asked by the question, and is neither Operable nor Inoperable.
NRC Resolution
The licensees recommendation was not accepted. Additionally, upon further review, it was
determined that choices A and B are both correct.
Tech Spec 3.5.3, requires that one ECCS subsystem SHALL be OPERABLE, including an
operable flow path capable of taking suction from the refueling water storage tank.
SOP-115, Residual Heat Removal, Rev 20, Section C (Plant Cooldown Using RHR Train A),
page 15 of 132 states:
Initiating cooldown on RHR while RCS Hot Leg temperatures are greater than 250°F
renders RHR Loop A incapable of being aligned to the RWST (reference Technical Specification 3.5.3.d) until the Hot Leg temperatures are reduced to less than 250°F.
Because SOP-115, Section C, stated that Train A was incapable of being aligned to the RWST
while aligned for shutdown cooling, Train A loop cannot be considered operable with respect to
Tech Spec 3.5.3. [The licensee contends that the Train A loop (when aligned for plant
cooldown) is neither operable nor inoperable.]
The stem question, as administered, was worded verbatim (including bolded portions) as
follows:
Which ONE (1) of the following describes the operability of RHR Train A with respect
to Technical Specification 3.5.3, ECCS SUBSYSTEMS - TAVG <350°F?
The question did NOT ask the applicants to decide if the requirements of LCO 3.5.3 were still
met. The question asked the applicants whether or not Train A was operable.
Furthermore, SAP-205, Status Control and Removal and Restoration, Rev 10, Section 4
(Definitions), Item 4.5 defines the term removal from service as follows:
Removal from Service: Alignment of a system or component or associated controls
such that the system is unavailable to perform its intended function as specified in the
Technical Specifications.
The licensees procedure for cooling down the plant (GOP-6, Plant Shutdown From Hot Standby
to Cold Shutdown, Mode 3 to Mode 5, Rev 11) includes the following Caution 3.5.d, on page 22
of 53:
In Mode 4, one train of ECCS must be capable of taking a suction from the RWST and
being manually realigned.
GOP-6 provides steps to ensure the adjacent train is protected which ensures that
requirements of Tech Spec 3.5.3 can still be met even though one of the RHR trains is being
used for plant cooldown and cannot be used to fulfill the operability requirements for Tech Spec 3.5.3.
Additionally, because both answer choices A and B deal with the flow path requirement
portion of Tech Spec 3.5.3, i.e., the loop being used for plant cooldown is not capable of being
aligned to the RWST due to pipe voiding concerns, then B is also correct. This was not initially
contended by the licensee. However, during the post exam analysis, the wording of answer
choice B was reviewed in detail. Even though the plant cooldown alignment, by itself, does
not render train A inoperable, it can be stated that the injection lineup cannot be achieved
when aligned to the RWST due to the voiding concerns at temperatures > 250oF.
Item
RO Question 33, K/A 027AK2.03
Licensee Comment
The licensee recommended that both choices B and D be accepted as correct answers.
The question is asking what is the output on the Master Pressure Controller in relationship to
the original value when the controller is placed in MANUAL by the operator. The licensee
contends that neither the Which One Of The Following (WOOTF) statement nor the conditions
stated in the stem clearly define what is meant by the ORIGINAL value. The licensee
contends that the correct answer to this question is dependent on the operators interpretation of
the ORIGINAL value.
The licensee contends that there are two possible interpretations of original:
1) The output of the Master Pressure Controller when PT-444 begins to drift HIGH
2) The output of the Master Pressure Controller when the Master Pressure Controller is
placed in MANUAL
If the point of reference is from when PT-444 begins to drift HIGH, then Choice B will be correct.
The output of the Master Pressure Controller will begin to increase in value above the output
signal of the Master Pressure Controller prior to the point where PT-444 began to drift HIG
- H.
Basically, this is testing how will the Master Pressure controller respond to the PT-444 failure?
The licensee contends that if the point of reference is from when the Master Pressure Controller
is placed in MANUAL, then Choice D will be correct. The manual control signal tracks the auto
signal if the applicant considers the ORIGINAL value to the controller output at the time the
controller was taken to MANUA
- L. Basically, this is testing the bumpless transfer function of
going from AUTO to MANUAL on the Master Pressure Controller. Therefore, depending on
how original is interpreted, the licensee contends that an applicant could determine either
Choice B or Choice D is correct.
NRC Resolution
The licensees recommendation was not accepted.
The licensee comment centers on whether it was clear what is meant by the word original in
the question statement: When placed in MANUAL, the output on the Master Pressure
Controller is _____ than its original output, AND the PZR Spray Valves will be approximately
____ open.
The bullets in the question stem were as follows:
Given the following plant conditions:
- 100% power
- PZR pressure control is in AUTO at 2235 psig
- Group 1 Backup Heaters are ON
- Group 2 Backup Heaters are OFF
- PT-444, PZR Pressure Transmitter, starts to slowly drift HIGH
- The operator places the Master Pressure Controller in MANUAL when PT-444 reads
275 psig, but does NOT adjust the output of the controller.
With the above in mind, there were three states in time:
state (i): 100% power, PZR pressure control in AUTO at 2235 psig, Group 1 B/U heaters ON
and Group 2 B/U heaters OFF
state (ii): beginning from state (i), PT-444 starts to slowly drift HIGH from 2235 to 2275 psig
state (iii): the moment the operator placed the controller in MANUAL but did NOT adjust the
output of the controller, at which time PT-444 read 2275 psig.
The question asks: When placed in MANUAL, the output is ___ than its original output, the
question is requiring the applicant to compare the controller at state (iii) to the controller at state
(i), which is the original condition provided in the question.
Furthermore, there were no requests from the applicants to clarify the meaning of this word
during the administration of the exam. Therefore, B was the only technically correct answer as
stated in the key.
Item
RO Question 35, K/A 029EK1.02
Licensee Comment
The licensee recommended that the question be deleted since there are no correct answers.
The question is asking what is the LOWEST Intermediate Range SUR that would generate an
Orange path to EOP-13.0. The licensee contends that none of the four choices defines the
LOWEST IR SUR that would generate the Orange Path. The licensee contends that any one of
the following could be the correct answer:
- just above zero
- >0.0
- not zero or negative
The licensee contends that while +0.2 would generate an Orange Path, it is not the lowest
possible IR SUR that would generate an Orange Path. The licensee contends that in order for
+0.2 to be correct, the stem would have to be worded similar to Of the following choices, which
ONE (1) is the LOWEST
Since the stem was worded Which ONE (1) of the following is the LOWEST the licensee
contends that none of the choices is correct (actually the lowest SUR).
NRC Resolution
The licensees recommendation was not accepted.
The licensee was essentially contending that the words in the question stem Which ONE (1) of
the following is the LOWEST Intermediate Range Startup Rate that will generate an ORANGE
Path transition to EOP-13.0, Response to Abnormal Nuclear Power Generation should be read
as follows: Which ONE (1) of the following is [the absolute lowest possible] IR SUR that will
generate an ORANGE Path transition However, that interpretation was an assumption,
which is not allowed in accordance with Appendix E of NUREG-1021.
Furthermore, that interpretation was a mis-reading of the question stem, which was linked to the
provided answer choices (Which one of the following ). Answer choices B, C, and D did
NOT require a transition to EOP-13.0 based on an ORANGE path. Answer choice A required a
transition to EOP-13.0. Therefore, A was the only technically correct answer as stated in the
key.
Item
RO Question 37, K/A 033G2.4.11
Licensee Comment
The licensee recommended that the question be deleted since there are no correct answers.
The question is asking what is the required action and maximum allowed power level, per
- T.S.
3.3.1, for an Intermediate Range (IR) channel failure. An IR channel failure is covered by
- T.S.
Table 3.3-1, Functional Unit 5, Action 3. The licensee contends that Action 3 consists of two
parts, neither of which requires placing the Level Trip Bypass Switch in BYPASS. The licensee
contends that placing the Level Trip Bypass Switch to Bypass is directed by AOP-401.8, Step 2;
not T.S. 3.3.1 (as stipulated in the stem). The licensee contends that choices A & B are not
correct, since T.S. does not require placing the Level Trip Bypass Switch in BYPAS
- S.
Furthermore, the licensee contends that the stem does not state that AOP-401.8 was entered.
Since examinees are not supposed to assume operator actions have occurred unless otherwise
told, they should not assume that AOP actions have been taken place. Because of this rule of
exam taking (from NUREG-1021, Appendix E, part B, Item #7), the licensee contends that the
applicants would eliminate Choices A & B.
Since bistables are not tripped (because this would result in a Reactor Trip) choices C & D are
not correct. Therefore, the licensee contends that there are no correct answers to the question.
NRC Resolution
The licensees recommendation was not accepted.
The licensee was contending that the words in accordance with Technical Specification 3.3.1 in the following question statement Which ONE (1) of the following is the required
action and the MAXIMUM allowed power level increase in accordance with Technical Specification 3.3.1 refer to both parts of the question statement. This was an incorrect
assumption (see below). Additionally, since IR detector N-35 had failed low as stated in the
stem, the entry conditions for AOP-401.8, Intermediate Channel Failure, had been met.
The question statement was asking a two part question: (1) what is the required action for
Intermediate Range Detector N-35 failing LOW [at 7% power], and (2) what is the MAXIMUM
allowed power level increase in accordance with TS 3.3.1? The fact that the required actions
for an IR range failure were covered in an AOP did not render the question invalid.
Furthermore, part (2) of the answer pertained to power limitations as delineated in the Technical
Specifications. Additionally, there were no questions raised during the examination from any of
the applicants. Therefore, A was the only technically correct answer as stated in the key.
Item
SRO Question 5 (Exam question 80), K/A 003AA2.03
Licensee Comment
The licensee recommended that the question be deleted since there are no correct answers.
The question asks how a Quadrant Power Tilt Ratio (QPTR) is confirmed with a failed Power
Range NI. Choice D was originally considered correct because of the provisions of Technical
Specification (TS). 4.2.4.2. The licensee contends that since the stem of the question
specifically asks in accordance with
- T.S. 3.2.4, there is no correct answer.
Actions under T.S. LCO 3.2.4 assume the QPTR will be calculated by the normal method per
STP-108.001. However, if a Power Range (PR) channel is out of service, the normal method is
precluded and its affect on QPTR is addressed in T.S. Table 3.3-1. The licensee contends that
Table 3.3-1, Functional Unit 3, Action 2# (not T.S. 3.4.2) requires the QPTR verification every
hours, using the Power Distribution Monitoring System (PDMS) or in-core detectors.
NRC Resolution
The licensees recommendation was not accepted.
The licensee contends that because the question asked in accordance with TS 3.2.4, and the
correct answer was taken from a surveillance requirement numbered 4.2.4.2, that the question
was invalid and has no correct answers.
T.S. 3/4.2.4 Surveillance Requirement 4.2.4.2 required that the QPTR shall be determined
within the limit when above 75 percent rate thermal power with one Power Range Channel
inoperable at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by using the PDMS or Movable Incore Detectors to
confirm that the normalized symmetric power distribution is consistent with the indicated QPTR.
The surveillance requirement in question was part of the overall technical specification that was
correctly referenced in the question stem. Therefore, D was the only technically correct
answer as stated in the key.
Item
SRO Question 21 (Exam question 96), K/A G2.4.41
Licensee Comment
The licensee recommended that both choices A & D be accepted as correct answers.
The question asks which set of conditions would require declaration of a Site Area Emergency
(SAE). Choice D clearly meets the conditions stated in SS1.1 (Via Table S-3 and Note 3). The
licensee contends that choice A, part 2), contains conditions (<108 VDC on both Train A and
Train B vital 125 VDC systems) which, by themselves, would require declaration of an SAE.
NRC Resolution
The licensees recommendation was accepted.
The licensee contends that the key answer of D was correct, and also that the set of conditions
in choice A was correct because they would also led to a declaration of Site Area Emergency
(SAE).
Based on a review of EPP-001 Attachment 2, the licensee is correct. Choices B and C were
double-checked to ensure they were not also correct. Therefore, both A and D were correct
answers. The answer key was changed to reflect this.
SIMULATOR FIDELITY REPORT
Facility Licensee: V.C. Summer
Facility Docket No.: 50-395
Operating Test Administered: June 30 - July 8, 2009
This form is to be used only to report observations. These observations do not constitute audit
or inspection findings and, without further verification and review in accordance with Inspection
Procedure 71111.11 are not indicative of noncompliance with 10 CFR 55.46. No licensee
action is required in response to these observations.
While conducting the simulator portion of the operating test, examiners observed the following:
Item Description
Rad Monitors Radiation recorders (R/R 1 thru R/R 12) located at panels XCP-
200 were not working. (i.e., not advancing or ON). R/R 5 did not
reflect increases on Pt 1 for the RML2A meter increases.
Pressurizer Backup A Group 1 heater switch malfunctioned on simulator performance
Heater Control Group 1 day 1 and then again on day 2. (On day 1, the applicant could not
get the heater group to re-start. On day 2, another applicant had
the heater group in pull-to-lock with the heater still energized).
Generator Turbine Trip On day 2, during the last two scenarios, the generator output
Relay (TTR) breaker/exciter breaker did not auto-open after the 30 second time
delay. The applicants identified it and manually opened it.
Additionally, it is unclear whether the simulator would reflect a
reverse power condition if the applicants had not manually
opened the breaker.
Critical Safety Function The Critical Safety Function Status Tree for Integrity may not have
Status Trees adequate tolerance bands for the good data values for cold leg
temperatures. This status tree frequently went purple (i.e., bad
data). Interviews with the applicants indicated that this frequently
happens because of the proximity of the SI injection to the cold leg