Submittal of 2008 Annual Radioactive Effluent Release Report
ML091280380
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 04/28/2009
From: Wilson M
Dominion Energy Kewaunee
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
09-183, FOIA/PA-2010-0209, LIC/NW/RO
Download: ML091280380 (84)


Text

Dominion Energy Kewaunee, Inc.

N490 Highway 42, Kewaunee, WI 54216-9511 z#Domi nioN ATTN: Document Control Desk Serial No.09-183 U. S. Nuclear Regulatory Commission LIC/NW/RO Washington, DC 20555-0001 Docket No.: 50-305 License No.: DPR-43 DOMINION ENERGY KEWAUNEE, INC.

KEWAUNEE POWER STATION 2008 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Enclosed is the Kewaunee Power Station (KPS) 2008 Annual Radioactive Effluent Release Report for January through December 2008. This report is submitted to meet the requirements of KPS Technical Specification 6.9.b.2 and 10 CFR 50.36a(a)(2).

If you have questions or require additional information, please feel free to contact Mr.

Mike Hale at 920-388-8103.

Very truly yours, J. Wilson Director Safety and Licensing Commitments made by this letter: NONE Enclosure iwz4

Serial No.09-183 Page 2 of 2 cc: Regional Administrator, Region III U. S. Nuclear Regulatory Commission 2443 Warrenville Road Suite 210 Lisle, IL 60532-4352 Mr. P. S. Tam Sr. Project Manager U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector Kewaunee Power Station Mr. W. A. Nestel Institute of Nuclear Power Operations 700 Galleria Parkway Atlanta, GA 30339 Mr. Don Hendrikse WI Division of Public Health Radiation Protection Section Room 150 Madison, Wl 53701-2659 Ms. Deborah Russo American Nuclear Insurers 95 Glastonbury Blvd.

Glastonbury, CT 06033

iW~Dominio 2008 Annual Radioactive Effluent Release Report Kewaunee Power Station Dominion Energy Kewaunee, Inc.

DOCKET 50-305 KEWAUNEE POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1 - December 31, 2008 Dominion Energy Kewaunee, Inc.

Table of Contents Section Description 0 .0 Summ ary .......................................................................................................... 3 1.0 Introduction .................................................................................................. ..3 1.1 Effl uent Dose .............................................................................. ................... 3 2.0 Gaseous Effluents ........................................  :..4 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents ............................. 4 2.2 Gaseous Batch Release Statistics .................................................................. 6 2.3 Gaseous Effluent Data .................................................................................. 6 Table 2.1 Gaseous Effluents - Summation of all Releases ............................ 7 Table 2.2 Gaseous Effluents - Elevated Releases ........................................ 8 Table 2.3A Gaseous Release Total .................................................................. 10 Table 2.3B Gaseous Release Continuous ................................................... 18 Table 2.3C Gaseous Release Batch .............................................................. 26 Table 2.4 Dose from Gaseous Effluents ..................................................... 34 3.0 Liquid Effluents ........................... ............................................................... 36 3.1 Lower Limits of Detection (LLD) for Liquid Effluents ............................... 36 3.2 Liquid Batch Release Statistics ........................................................................ 38 3.3 Liquid Effluent Data ................................................................................... 38 Table 3.1 Liquid Effluents - Summation of all Releases ............................. *39 Table 3.2A Liquid Effluents - Batch Releases 1st Quarter ........................ 40 Table 3.2B Liquid Effluents - Batch Releases 2nd Quarter ......................... 42 Table 3.2C Liquid Effluents - Batch Releases 3rd Quarter ........................ 44 Table 3.2D Liquid Effluents - Batch Releases 4th Quarter ............. 46 Table 3.3A Liquid Effluents - Continuous Releases 1st Quarter ................ 48 Table 3.3B Liquid Effluents - Continuous Releases 2nd Quarter ............... 50 Table 3.3C Liquid Effluents - Continuous Releases 3rd Quarter ............... 52 Table 3.3D Liquid Effluents - Continuous Releases 4th Quarter ............... 54 Table 3.4 Dose from Liquid Effluents ........................................................ 56 Table 3.5 Ground Water Monitoring .......................................................... 58 4.0 U nplanned Releases ................................................................................... 60 5.0 M eteorological D ata ................................................................................... 60 6.0 Solid Waste D isposal ................................................................................ 60 Table 6.1 Solid Waste and Irradiated Fuel Shipments ............................... 61 7.0 Program Revisions ...................................................................................... 63 8.0 Reportable Occurrences ............. ........................ 63 Appendix A Meteorological Data Appendix B Event Notification Worksheet Page 2 of 63

0.0

SUMMARY

During 2008 all solid, liquid, and gaseous radioactive effluents from the Kewaunee Nuclear Plant were well below regulatory limits. For individual effluent streams, the quarterly limit most closely approached was:

GASEOUS: Ingestion Pathway-Organ Liver Quarterly Limit (mRems) 7.5 Actual Dose (mRems) 3.559E-4 ( 2 nd Quarter)

% of Specification 0.004745 LIQUID: Ingestion Pathway-Organ Total Body Quarterly Limit (mRems) 1.5 Actual Dose (mRems) 5.408E-4 (1st Quarter)

%of Limit 0.03606 SOLID: No upper limit for solid radioactive waste applies.

Cubic Meters Shipped 86.24 m3

1.0 INTRODUCTION

This report is being submitted in accordance with the requirements of Kewaunee Technical Specifications, Section 6.9.b.2 and the Offsite Dose Calculation Manual, Section 3/4.7. It includes data from all effluent releases made from January 1 - December 31, 2008. The report contains summaries of the gaseous and liquid releases made to the environment including the quantity, characterization, time duration and calculated radiation dose at the site boundary resulting from these releases. The report also includes a summation of solid waste disposal, revisions to the Process Control Program and the Offsite Dose Calculation Manual, and addresses the cumulative meteorological data. Values indicated as 0 (zero) in this report refer to actual values less than the detection limits. A table of these less than (LLD) values is identified in sections 2.1 and 3.1.

1.1 Effluent Dose Limits Specifications are set to insure that offsite doses are maintained as low as reasonably achievable while still allowing for practical and dependable operation of the Kewaunee Plant.

The Kewaunee Offsite Dose Calculation Manual (ODCM) describes the methodology and parameters used in:

1.) The calculation of radioactive liquid and gaseous effluent monitoring instrumentation alarm/trip setpoints.

2.) The calculation of radioactive liquid and gaseous concentrations, dose rates and cumulative quarterly and annual doses. The ODCM methodology is acceptable for use in demonstrating compliance with 10 CFR 20.106; 10 CFR 50, Appendix I; and 40 CFR 190.

Page 3 of 63

I 2.0 GASEOUS EFFLUENTS I 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents I Gaseous radioactive effluents are released in both the continuous mode and the batch mode. The auxiliary building stack is sampled continuously for particulates, halogens and Strontium by an "off-line" sample train. This stack is also grab-sampled daily for gaseous gamma emitters. Batch releases I

are sampled prior to release for principal gaseous and particulate gamma emitters, halogens and tritium.

I The LLD's for gaseous radioanalyses, as listed in Table 4.4 of the Kewaunee ODCM are:

Analysis LLD ([tCi/ml) i Gaseous Gamma Emitters Iodine 131 1.00 3.00 E-04 E-12 I

Particulate Gamma Emitters 1.00 E-1I Particulate Gross Alpha Strontium 89, 90 1.00 1.00 E-11 E-1I I

Noble Gases, Gross Beta or Gamma 1.00 E-06 I

The nominal "a priori" LLD values are shown below.

Isotope a priori LLD (jiCi/ml) 3

a. Gaseous emissions: I Kr-87 5.61E-08 Kr-88 1.02E-07 i Xe-133 6.68E-08 Xe-133m 2.75E-07 Xe-135 2.99E-08 i Xe-138 1.13E-07 I

I I

I Page 4 of 63 I I

b. Particulate emissions:

Mn-54 1.11 E-13 Fe-59 2.27E-13 Co-58 2.28E-13 Co-60 3.57E-13 Zn-65 1.68E-13 Mo-99 2.73E-13 Cs-134 4.69E-13 Cs-137 1.68E-13 Ce-141 2.08E-13 Ce-144 1.24E-12

c. Other identifiable gamma emitters:

Ar-41 3.97E-10 Kr-85 8.63E-05 Kr-85m 4.62E-08 Kr-89 2.04E-06 Xe-127 4.20E-08 Xe-131m 1.82E-06 Xe-135m 1.90E-08 Xe-137 2.88E-07 1-131 1.32E-13

d. Composite particulate samples:

Sr-89 1 E-14 Sr-90 1 E-14 Gross Alpha 1.00 E-14 These "a priori" LLDs represent the capabilities of the counting systems in use, not an after the fact "a posteriori" limit for a particular measurement.

Page 5 of 63

I 2.2 Gaseous Batch Release Statistics U The following is a summation of all gaseous batch releases made during 2008.

Number of batch releases ....................... 53 I

Total time for all batch releases (min) ............ 26,120.0  !

Maximum time for a batch release (min) ............. 2,305.0 I

Average time for a batch release (min) ............. 492.8 Minimum time for a batch release (min) ............. 7.0 i 2.3 Gaseous Effluent Data I

The following table 2.1 presents a quarterly summation of the total activity released and average release rates of four categories of gaseous effluents. Table 2.2 lists the quarterly sums of individual gaseous radionuclides released by continuous and batch modes. Table 2.3 is essentially the same data, but is presented as monthly summations. Table 2.4 presents the dose limits for gaseous effluents, and the calculated doses this year from gaseous effluents.

I I

I I

I I

I I

I Page 6 of 63 I I

Table 2.1 Annual Radioactive Effluent Release Report 2008 Gaseous Effluents - Summation of all Releases Fission and Activation Gases 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Total Activity Released (Ci) 5.882E-002 2.382E-002 2.614E-005 1.908E-005 Average Release Rate ([tCi/sec) 7.481E-003 3.030E-003 3.325E-006 2.427E-006 Iodines Total Activity Released (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 o.OOOE+000 Average Release Rate (p.Ci/sec) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Particulates Total Activity Released (Ci) O.OOOE+000 O.OOOE+000 1.744E-006 O.OOOE+000 Average Release Rate (VCi/sec) O.OOOE+000 O.OOOE+000 2.218E-007 O.OOOE+000 Gross Alpha Released (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Tritium Total Activity Released (Ci) 1.950E+000 1.685E+001 3.822E+000 3.546E+000 Average Release Rate (!iCi/sec) 2.481E-001 2.143E+000 4.861E-001 4.5 11E-001 Page 7 of 63

I Table 2.2 Annual Radioactive Effluent Release Report 2008 Gaseous Effluents I

Nuclides Released (Ci)

Continuous Mode 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter I Fission Gases Total 0.000E+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 I

lodines I Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 i

Particulates Mn-54 O.OOOE+000 0.OOOE+000 1.260E-007 0.OOOE+000 Co-58 O.OOOE+000 0.OOOE+000 1.220E-006 0.OOOE+000 Co-60 O.OOOE+000 O.OOOE+000 2.460E-007 0.OOOE+000 Cs-137 O.OOOE+000 0.OOOE+000 1.520E-007 0.OOOE+000 Total 0.00OE+000 O.OOOE+000 1 744E-006 0.OOOE+000 I

i I

I I

I I

i Page 8 of 63 I

Table 2.2(cont)

Annual Radioactive Effluent Release Report 2008 Gaseous Effluents Nuclides Released (Ci)

Batch Mode Fission Gases Ar-41 O.OOOE+000 5.376E-005 O.OOOE+000 0.OOOE+000 Kr-85m O.OOOE+000 7.537E-006 O.OOOE+000 0.OOOE+000 Xe-133m 1.299E-003 2.345E-004 0.OOOE+000 0.OOOE+000 Xe-133 5.312E-002 2.332E-002 2.614E-005 1.908E-005 Xe-135 4.402E-003 2.104E-004 0.000E+000 0.000E+000 Total 5.882E-002 2.3 82E-002 2.614E-005 1.908E-005 lodines Total 0.000E+000 O.OOOE+000 0.000E+000 0.OOOE+000 Particulates Total 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Page 9 of 63

I Table 2.3A Annual Radioactive Effluent Release Report 2008 I

1st Quarter Gaseous Release Total of all Releases I Noble Gasses (Curies)

Isotope January February March Total I

Xe-133m O.OOOE+000 0.OOOE+000 3.282E-003 1.299E-003 4.984E-002 1.299E-003 5.312E-002 3

Xe-133 O.OOOE+000 Xe-135 0.OOOE+000 0.OOOE+000 4.402E-003 4.402E-003 Total 0.OOOE+000 3.282E-003 5.554E-002 5.882E-002 1 Particulates (Curies)

I Isotope January February March Total Total 0.OOOE+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 I

Halogens (Curies)

Isotope January February March Total I

Total O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 U I

I I

I I

I Page 10 of 63 I

I

Table 2.3A (Con't)

Annual Radioactive Effluent Release Report 2008 1st Quarter Gaseous Release Total of all Releases Summary January February March Total Total Noble Gases (Ci) O.OOOE+000 3.282E-003 5.554E-002 5.882E-002 Total Halogens (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Total Tritium (Ci) 4.525E-001 6.771E-005 1.498E+000 1.950E+000 Total Particulate Gross Alpha (Ci) O.OOOE+O00 0.00OE+000 0.OOOE+000 0.OOOE+000 Page 11 of 63

I Table 2.3A (Con't)

Annual Radioactive Effluent Release Report 2008 I

2nd Quarter Gaseous Release Total of all Releases I Noble Gasses (Curies) I Isotope April May June Total I

Ar-41 O.OOOE+000 5.376E-005 0.OOOE+000 5.376E-005 Kr-85m Xe-133m O.OOOE+000 2.345E-004 7.537E-006 O.OOOE+000 O.OOOE+000 O.OOOE+000 7.537E-006 2.345E-004 I

Xe-133 2.318E-002 1.394E-004 0.OOOE+000 2.332E-002 Xe-135 Total 7.107E-005 2.348E-002 1.393E-004 3.400E-004 O.OOOE+000 0.OOOE+000 2.104E-004 2.3 82E-002 I

Particulates (Curies) i Isotope April May June Total I Total 0.OOOE+000 O.OOOE+O00 O.OOOE+O00 O.O00E+000 I

Halogens (Curies)

Isotope April May June Total I

Total 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 I I

I I

i I

Page 12 of 63

/

I

Table 2.3A (Con't)

Annual Radioactive Effluent Release Report 2008 2nd Quarter Gaseous Release Total of all Releases Summary April May June Total Total Noble Gases (Ci) 2.348E-002 3.400E-004 O.O00OE+000 2.382E-002 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Total Tritium (Ci) 1.211 E+001 4.020E+000 7.127E-001 1.685E+001 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.OOOE+000 O.O00OE+000 O.OOOE+000 Page 13 of 63

I Table 2.3A (con't)

Annual Radioactive Effluent Release Report 2008 I

3rd Quarter Gaseous Release Total of all Releases I Noble Gasses (Curies)

Isotope July August September Total I

Xe-133 O.OOOE+000 O.OOOE+000 2.614E-005 2.614E-005 I Total O.OOOE+000 O.OOOE+000 2.614E-005 2.614E-005 Particulates (Curies) i Isotope Mn-54 July O.OOOE+000 August 1.260E-007 September O.OOOE+000 Total 1.260E-007 i

Co-58 Co-60 O.OOOE+000 O.OOOE+000 1.220E-006 2.460E-007 O.OOOE+000 O.OOOE+000 1.220E-006 2.460E-007 I Cs-137 O.OOOE+000 1.520E-007 O.OOOE+000 1.520E-007 Total O.OOOE+000 1.744E-006 0.00OE+000 1.744E-006 Halogens (Curies) I Isotope July August September Total I

Total 0.OOOE+/-000 0.OOOE+000 0.OOOE+000 0.OOOE+000 I

I I

I I

I Page 14 of 63 I

I

Table 2.3A (Con't)

Annual Radioactive Effluent Release Report 2008 3rd Quarter Gaseous Release Total of all Releases Summary July August September Total Total Noble Gases (Ci) O.OOOE+000 O.OOOE+000 2.614E-005 2.614E-005 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 1.744E-006 O.OOOE+000 1.744E-006 Total Tritium (Ci) 3.952E-001 8.615E-001 2.565E+000 3.822E+000 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 15 of 63

Table 2.3A (Con't)

Annual Radioactive Effluent Release Report 2008 4th Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)

Isotope October November December Total Xe-133 1.908E-005 O.OOOE+000 O.OOOE+000 1.908E-005 Total 1.908E-005 O.OOOE+000 O.OOOE+000 1.908E-005 Particulates (Curies)

Isotope October November December Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)

Isotope October November December Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 16 of 63

Table 2.3A (Con't)

Annual Radioactive Effluent Release Report 2008 4th Quarter Gaseous Release Total of all Releases Summary October November December Total Total Noble Gases (Ci) 1.908E-005 0.000E+000 0.OOOE+O000 1.908E-005 Total Halogens (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+/-000 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+O00 0.OOOE+000 Total Tritium (Ci) 8.631E-001 5.963E-001 2.087E+000 3.546E+000 Total Particulate Gross Alpha (Ci) O.OOOE+O00 O.OOOE+000 0.OOOE+000 0.OOOE+000 Page 17 of 63

Table 2.3B Annual Radioactive Effluent Release Report 2008 1st Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)

Isotope January February March Total Total O.OOOE+000 O.OOOE+O00 O.OOOE+000 O.OOOE+000 I

Particulates (Curies) P Isotope January February March Total Total O.OOOE+000 O.OOOE+000 O.OOOE+O00 O.OOOE+O00 Halogens (Curies)

Isotope January February March Total Total O.OOOE+000 O.OOOE+O00 0.00OE+000 0.OOOE+000 Page 18 of 63

Table 2.3B (Con't)

Annual Radioactive Effluent Release Report 2008 1st Quarter Gaseous Release Continuous Mode Only Summary January February March Total Total Noble Gases (Ci) O.OOOE+000 O.OOOE+000 0.00OE+000 O.O00E+000 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Total Tritium (Ci) 4.477E-00 1 O.OOOE+O00 1.498E+000 1.945E+000 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.OOOE+000 O.OOOE+000 0.OOOE+000 Page 19 of 63

Table 2.3B (Con't)

Annual Radioactive Effluent Release Report 2008 2nd Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)

Isotope April May June Total Total O.OOOE+O00 O.OOOE+O00 O.OOOE+000 O.OOOE+000 Particulates (Curies)

Isotope April May June Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)

Isotope April May June Total Total O.OOOE+000 0.000E+000 O.OOOE+000 0.OOOE+000 Page 20 of 63

Table 2.3B (Con't)

Annual Radioactive Effluent Release Report 2008 2nd Quarter Gaseous Release Continuous Mode Only Summary April May June Total Total Noble Gases (Ci) O.OOOE+000 0.OOOE+O00 0.OOOE+/-O000 0.OOOE+OOO Total Halogens (Ci) O.OOOE+000 0.OOOE+O0O 0.OOOE+000 0.OOOE-i-000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.000E+000 Total Tritium (Ci) 1.181E+001 4.009E+000 7.126E-001 1.653E+001 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0 OOOE+000 0.OOOE+000 O.OOOE+000 Page 21 of 63

Table 2.3B (con't)

Annual Radioactive Effluent Release Report 2008 I

3rd Quarter Gaseous Release Continuous Mode Only i Noble Gasses (Curies)

I Isotope July August September Total Total O.OOOE+O00 0.000E+000 O.OOOE+O00 0.000E+000I Particulates (Curies)

Isotope July August September Total I Mn-54 Co-58 O.OOOE+000 O.OOOE+000 1.260E-007 1.220E-006 O.OOOE+000 O.OOOE+000 1.260E-007 1.220E-006 I

Co-60 O.OOOE+000 2.460E-007 O.OOOE+000 2.460E-007 Cs-137 Total O.OOOE+000 O.OOOE+000 1.520E-007 1.744E-006 O.OOOE+000 O.OOOE+000 1.520E-007 1.744E-006 I

Halogens (Curies) I Isotope July August September Total I

Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+O00 I

.I

,I I

I I

Page 22 of 63 I

I

Table 2.3B (Con't)

Annual Radioactive Effluent Release.Report 2008 3rd Quarter Gaseous Release Continuous Mode Only Summary July August September Total Total Noble Gases (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 0.00OE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 1.744E-006 O.OOOE+000 1.744E-006 Total Tritium (Ci) 3.952E-001 8.615E-001 2.565E+000 3.822E+000 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.0003E+000 O.OOOE+000 0.OOOE+000 Page 23 of 63

Table 2.3B (Con't)

Annual Radioactive Effluent Release Report 2008 4th Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)

Isotope Octc ber November December Total Total O.OOOE+O00 0.000E+000 0.00OE+000 0.000E+000 Particulates (Curies)

Isotope October November December Total Total 0.OOOE+000 0.00OE+000 O.OOOE+O00 O.OOOE+000 Halogens (Curies)

Isotope October November December Total Total O.OOOE+000 0.OOOE+000 0.OOOE+000 O.OOOE+O00 Page 24 of 63

Table 2.3B (Con't)

Annual Radioactive Effluent Release Report 2008 4th Quarter Gaseous Release Continuous Mode Only Summary October November December Total Total Noble Gases (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 o.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 8.546E-001 5.890E-001 2.078E+000 3.521E+000 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+O00 Page 25 of 63

I Table 2.3C Annual Radioactive Effluent Release Report 2008 I

1st Quarter Gaseous Release Batch Mode Only I Noble Gasses (Curies)

Isotope January February March Total I

Xe-133m Xe-133 O.OOOE+000 O.OOOE+000 O.OOOE+000 3.282E-003 1.299E-003 4.984E-002 1.299E-003 5.312E-002 I

.Xe-135 O.OOOE+000 Total 0.00OE+000 O.OOOE+000 3.282E-003 4.402E-003 5.554E-002 4.402E-003 5.882E-002 I Particulates (Curies)

Isotope January February March. Total I Total O.OOOE+000 O.OOOE+000 O.OOOE+O00 O.OOOE+000 U Halogens (Curies) I Isotope January February March Total Total O.OOOE+O00 O.OOOE+000 O.OOOE+000 O.O00E+O00I I

I I

I I

I I

Page 26 of 63 I

Table 2.3C (Con't)

Annual Radioactive Effluent Release Report 2008 1st Quarter Gaseous Release Batch Mode Only Summary January February March Total Total Noble Gases (Ci) O.OOOE+000 3.282E-003 5.554E-002 5.882E-002 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE-000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 4.797E-003 6.771E-005 2.940E-004 5.159E-003 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 27 of 63

I Table 2.3C (Con't)

Annual Radioactive Effluent Release Report 2008 I

2nd Quarter Gaseous Release Batch Mode Only I Noble Gasses (Curies)

Isotope April May June Total I

Ar-41 Kr-85m O.OOOE+000 O.OOOE+000 5.376E-005 7.537E-006 O.OOOE+000 O.OOOE+000 5.376E-005 7.537E-006 I

Xe-133m Xe-133 2.345E-004 2.318E-002 O.OOOE+000 1.394E-004 O.OOOE+000 O.OOOE+000 2.345E-004 2.332E-002 I Xe-135 7.107E-005 1.393E-004 O.OOOE+000 2.104E-004 Total 2.348E-002 3.400E-004 0.OOOE+000 2.382E-002 I

Particulates (Curies)

I Isotope April May June Total Total 0.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 I Halogens (Curies)

I Isotope April May June Total I Total O.OOOE+000 0.OOOE+000 0.OOOE+000 O.OOOE+O00 I

I I

I I

I Page 28 of 63 I

I

Table 2.3C (Con't)

Annual Radioactive Effluent Release Report 2008 2nd Quarter Gaseous Release Batch Mode Only Summary April May June Total Total Noble Gases (Ci) 2.348E-002 3.400E-004 0.OOOE+000 2.382E-002 Total Halogens (Ci) 0.000E+000 0.OOOE+000 0.OOOE+/-000 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 0.OOOE+000 0.000E+/-000 O.OOOE+000 Total Tritium (Ci) 3.032E-001 1.059E-002 1.143E-004 3.139E-001 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.000E+000 0.OOOE+000 O.OOOE+000 Page 29 of 63

I Table 2.3C (con't)

I Annual Radioactive Effluent Release Report 2008 3rd Quarter Gaseous Release Batch Mode Only I

Noble Gasses (Curies)

I Isotope July August September Total 2'.14E-005I Xe-133 0.OOOE+000 0OOOOE+OOO 2.614E-005 Total 0.OOOE+000 0.OOOE+/-000 2.614E-005 2.614E-005 Particulates (Curies)

Isotope July August September Total I

Total O.OOOE+000 0.OOOE+000 0.OOOE+000 O.OOOE+000 I

Halogens (Curies)

I Isotope July August September Total I O.OOOE+O00 Total 0.000E+000 0.OOOE+000 0.OOOE+000 I

I I

I I

I I

Page 30 of-63 I

I

Table 2.3C (Con't)

Annual Radioactive Effluent Release Report 2008 3rd Quarter Gaseous Release Batch Mode Only Summary July August September Total Total Noble Gases (Ci) O.OOOE+O00 0.00OE+000 2.614E-005 2.614E-005 Total Halogens (Ci) O.OOOE+O00 O.OOOE+000 0.OOOE+000 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+/-000 0.OOOE+O000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) O.OOOE+/-000 0.OOOE+000 1.060E-005 1.060E-005 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.OOOE+000 O.OOOE+O00 0.000E+000 Page 31 'of 63

Table 2.3C (Con't)

Annual Radioactive Effluent Release Report 2008 4th Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)

Isotope October November December Total Xe-133 1.908E-005 O.OOOE+000 O.OOOE+000 1.908E-005 Total 1.908E-005 O.OOOE+000 O.OOOE+000 1.908E-005 Partiulats (Cries Isotope October November December Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)

Isotope October November December Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 32 of 63

Table 2.3C (Con't)

Annual Radioactive Effluent Release Report 2008 4th Quarter Gaseous Release Batch Mode Only Summary October November December Total Total Noble Gases (Ci) 1.908E-005 0.OOOE+000 0.0OOE+000 1.908E-005 Total Halogens (Ci) 0.OOOE+000 0.OOOE+000 O.OOOE+000 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+/-000 0.OOOE+000 0.OOOE+/-000 o.OOOE+000 Total Tritium (Ci)- 8.501E-003 7.27 1E-003 9.223E-003 2.499E-002 Total Particulate Gross Alpha (Ci) 0.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Page 33 of 63

I Table 2.4 Annual Radioactive Effluent Release Report 2008 I Dose from Gaseous Effluents The offsite dose limits from radioactive materials in gaseous effluents are specified in Section 3/4.4 of I the Kewaunee ODCM and can be summarized as follows:

Whole Body Skin Limit Gamma Beta Organ Quarterly 5.0 mRad 10.0 mRad 7.5 mRem I

Annual 10.0 mRad 20.0 mRad 15.0 mRem The total release of gaseous effluents during each quarter of 2008 was within limits. The following I

offsite doses were calculated using equations 2.7, 2.8, and 2.11 from the Kewaunee ODCM.

Calculated offsite doses versus quarterly limits are shown below: I 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr I

1. Gamma-Whole Body I Specification (mRads) 5.OOOE+000 5.OOOE+000 5.OOOE+000 5.OOOE+000 Actual Dose (mRads)

% of Specification 3.153E-006 6.306E-005 1.052E-006 2.104E-005 1.053E-009 7.687E-010 2.106E-008 1.537E-008 I

2. Beta-Skin Specification (mRads) 1.000E+001 1.000E+001 1.000E+001 1.OOOE+001 I

Actual Dose (mRads) 7.820E-006 2.914E-006 3.132E-009 2.287E-009

% of Specification 7.820E-005 2.914E-005 3.132E-008 2.287E-008 I

3. Ingestion Pathway-Organ Specification (mRems) 7.500E+000 Actual Dose (mRems) 4.120E-005 7.500E+000 3.559E-004 7.500E+000 8.289E-005 7.500E+000 7.492E-005 I

% of Specification 5.494E-004 1.105E-003 Liver 4.745E-003 Liver Liver 9.989E-004 Liver I I

I Page 34 of 63 i I

Table 2.4 (Con't)

Annual Radioactive Effluent Release Report 2008 Dose from Gaseous Effluents In addition, the cumulative annual offsite doses for the period January 1 - December 31, 2008 versus the ODCM annual limits were:

Annual I. Gamma-Whole Body Specification (mRads) 1.OOOE+001 Actual Dose (mRads) 4.207E-006

% of Specification 4.207E-005

2. Beta-Skin Specification (mRads) 2.OOOE+001 Actual Dose (mRads) 1.074E-005

% of Specification 5.370E-005

3. Ingestion Pathway-Organ Specification (mRems) 1.500E+001 Actual Dose (mRems) 5.549E-004

% of Specification 3.699E-003 Liver Page 35 of 63

I 3.0 LIQUID EFFLUENTS 3 3.1 Lower Limits of Detection (LLD) for Liquid Effluents Liquid radioactive effluents are released as both batch releases and continuous releases. Each batch is i sampled prior to release and analyzed for gamma emitters and tritium. A fraction of each sample is retained for a monthly proportional composite which is then analyzed for Gross Alpha, Strontium 89, Strontium 90 and Iron 55.

The LLD's for liquid batch release radioanalyses, as listed in Table 4.3 of the Kewaunee Nuclear Power Plant Off-Site Dose Calculation Manual, are:

Analysis Principal Gamma Emitters LLD (UCi/ml) 1.00 E-06 3

Iodine 131 1.00 E-06 Tritium 1.00 E-05 i Gross Alpha 5.00 E-07 Strontium 89, 90 5.00 E-08 Iron 55 1.00 E-06 The actual obtained "a priori" LLD values for batch releases are shown below. 3 Isotope 1st 2nd 3rd 4th Average a Quarter Quarter Quarter Quarter priori LLD Mn-54 7.81E-10 7.88E-10 7.88E-10 7.88E-10

([LCi/ml) 7.86E-10 3 Fe-59 1.75E-09 1.75E-09 1.75E-09 1.75E-07 4.51E-08 Co-58 7.73E-10 7.73E-10 1.09E-07 7.73E-10 2.78E-08 Co-60 1.04E-09 1.05E-07 1.17E-09 1.05E-09 2.71E-08i Zn-65 1.97E-09 2.79E-07 1.98E-09 1.98E-09 7.12E-08 Mo-99 5.55E-09 5.56E-09 7.44E-07 5.56E-09 1.90E-07 Cs-134 6.12E-08 1.31E-07 6.13E-10 6.13E-10 4.84E-08 Cs-137 7.59E-10 7.59E-10 7.59E-10 1.28E-07 3.26E-08 Ce-141 Ce- 144 4.77E-08 1.76E-09 9.80E-08 4.45E-07 1.04E-07 4.59E-07 1.05E-07 5.18E-07 8.87E-08 3.56E-07 3

1-131 5.18E-08 4.64E-10 9.76E-08 5.19E-08 5.04E-08 H-3 2.96E-06 2.58E-06 2.91E-06 2.92E-06 2.84E-06 Sr-89 1.28E-08 1.56E-08 1.84E-08 1.08E-08 1.44E-08 Sr-90 6.32E-09 8.62E-09 8.48E-09 9.28E-09 8.18E-09 1.00E-08 3

Gross Alpha 9.75E-09 9.94E-09 8.79E-09 1.17E-08 Fe-55 6.55E-07 6.53E-07 6.95E-07 8.84E-07 7.22E-07 Page 36 of 63 I I

Continuous liquid releases are grab sampled weekly and analyzed for principal gamma emitters. A fraction of each weekly sample is retained for a monthly proportional composite which is then analyzed for Tritium, Gross Alpha, Strontium 89, Strontium 90 and Iron 55.

The LLD's for liquid continuous release radioanalyses, as listed in Table 4.3 of the Kewaunee Nuclear Power Plant Off-Site Dose Calculation Manual, are:

Analysis LLD (ltCi/ml)

Principal Gamma Emitters 5.00 E-07 Iodine 131 1.00 E-06 Tritium 1.00 E-05 Gross Alpha 5.00 E-07 Strontium 89, 90 5.00 E-08 Iron 55 1.00 E-06 The actual obtained "a priori" LLD values for continuous releases are shown below.

Isotope 1 st 2nd 3rd' 4th Average a Quarter Quarter Quarter Quarter priori LLD

([tCi/ml)

Mn-54 1.31E-10 1.49E-08 142E-08 5.64E-11 7.32E-09 Fe-59 2.92E-10 1.52E-08 2.19E-08 1.27E-08 1.25E-08 Co-58 1.28E-10 6.65E-09 2.72E-08 2.50E-08 1.47E-08 Co-60 4.34E-08 1.07E-08 8.48E-09 1.66E-08 1.98E-08 Zn-65 3.29E- 10 1.60E-08 1.43E-10 1.43E-08 7.69E-09 Mo-99 1.90E-07 1.18E-07 3.98E-10 9.59E-08 1.O1E-07 Cs-134 3.38E-08 4.34E- 11 1.09E-08 1.38E-08 1.46E-08 Cs-137 1.26E-10 1.64E-08 1.98E-08 5.39E- 11 9.09E-09 Ce-141 6.60E-08 2.58E-08 1.44E-08 2.94E-11 2.66E-08 Ce-144 1.72E-07 9.82E-08 7.16E-08 9.96E-08 1.1OE-07 1-131 2.99E-08 3.24E- 11 1.49E-08 9.60E-09 1.36E-08 H-3 2.96E-06 2.58E-06 2.91E-06 2.92E-06 2.84E-06 Sr-89 1.36E-08 1.92E-08 1.63E-08 1.12E-08 1.51E-08 Sr-90 7.67E-09 1.06E-08 8.36E-09 8.66E-09 8.82E-09 Gross Alpha 7.OOE-09 6.96E-09 1.48E-09 5.71E-09 5.29E-09 Fe-55 6.61E-07 6.43E-07 7.15E-07 8.07E-07 7.07E-07 Page 37 of 63

I 3.2 Liquid Batch Release Statistics I The following is a summation of all liquid batch releases made during 2008.

I Release Type A SGBT Monitor Tk.

B SGBT Monitor Tk.

Number 13 14 Gallons Released 120,281 122,655 I

A CVC Monitor B CVC Monitor 6

6 39,830

.38,815 I Both WCTs 3 4,385 I

Total time for all batch releases ................ 15,315 Min.

Maximum time for a batch release ............... 629 Min.

i Minimum time for a batch release ................. 5 Min. I Average time for a batch release .............. 364.6 Min.

I I

3.3 Liquid Effluent Data I The following Table 3.1 presents a quarterly summation of the total activity released and average concentration for all liquid effluents. It also presents the gross alpha activity released, volume of waste I released and volume of dilution water used. Tables 3.2 and 3.3 are monthly summations of the same information in Table 3.1. Table 3.2 contains the quantity of the individual isotopes released to the unrestricted area for batch releases. Table 3.3 presents a monthly summation of gross radioactivity, I tritium, gross alpha and isotopic activity for the secondary blowdown and leakage releases. It also presents the monthly total volume for these releases and dilution volumes. Table 3.4 presents the doses from liquid effluents for each quarter and the calculated doses this year from liquid effluents.

I I

I I

Page 38 of 63 I

I

TABLE 3.1 Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Summation of all Releases 1st Qtr 2nd Qtr 3rdQtr 4th Qtr Fission and Activation Products Total Release Excluding H3 and Dissolved Gases (Ci) 4.629E-003 1.611E-002 1.534E-003 5.760E-004 Average Concentration (iiCi/ml) 3.176E-0 11 1.019E-010 7.520E-012 3.317E-012 Tritium Total Release (Ci) 6.305E+001 3.944E+001 1.761E+001 3.917E+001 Average Concentration

([Ci/ml) 4.327E-007 2.495E-007 8.630E-008 2.256E-007

% of Tech. Spec.

Limit(3.OE-3 VCi/ml) 1.442E-002 8.317E-003 2.877E-003 7.520E-003 Dissolved Gases Total Release (Ci) 5.389E-005 1.027E-004 O.OOOE+000 O.OOOE+000 Average Concentration (jiCi/ml) 3.698E-013 6.496E-0 13 O.OOOE+000 0.00OE+000

% of Tech. Spec.

Limit(2.0E-4 pCi/ml) 1.849E-007 3.248E-007 O.OOOE+000 0.OOOE+000 Gross Alpha Activity Total Release (Ci) O.OOOE+000 O.OOOE+O00 O.OOOE+000 0.00OE+000 Volume of Waste Released Batch (liters) 3.582E+005 3.244E+005 3.034E+005 2.477E+005 Continuous (liters) 2.265E+007 2.497E+007 1.712E+007 1.999E+007 Total (liters) 2.301E+007 2.530E+007 1.742E+007 2.024E+007 Volume of Dilution Water Batch (liters) 4.411E+009 3.836E+009 5.170E+009 3.945E+009 Continuous (liters) 1.413E+O11 1.542E+011 1.988E+01 1 1.697E+O 11 Total (liters) 1.457E+01 1 1.580E+O11 2.040E+O1 1 1.736E+O 11 Page 39 of 63

TABLE 3.2A Annual Radioactive Effluent Release Report 2008

'Liquid Effluents - Batch Releases March Total Gross Radioactivity January February I

Total Release I

Excluding H3 and Dissolved Gases (Ci) 2.525E-004 7.13 8E-004 3.663E-003 4.629E-003 Avg. Cone.

([iCi/ml) 9.161E-010 9.382E-010 1.085E-009 Tritium Total Release (Ci) 4.379E+000 7.036E+000 5.163E+001 6.305E+001 Avg. Cone.

([iCi/ml) 1.589E-005 9.247E-006 1.530E-005 Dissolved Gases Total Release (Ci) O.OOOE+000 0.OOOE+000 5.389E-005 5.3 89E-005 Avg. Cone.

(VCi/ml) O.OOOE+000 0.OOOE+000 1.597E-01 1 Gross Alpha Activity Total Release (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+000 0.000E+000 Avg. Conc.

(ýICi/ml) O.OOOE+000 0.OOOE+000 0.OOOE+000 Volume of Waste Released (liters) 3.705E+004 7.345E+004 2.477E+005 3.582E+005 Volume of Dilution Water (liters) 2.755E+008 7.608E+008 3.375E+009 4.41 1E+009 Page 40 of 63

TABLE 3.2A (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases Isotope (Ci) January February March Total Ag-i10m 1.980E-005 3.41OE-005 2.048E-004 2.587E-004 Alpha O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Ar-41 O.OOOE+000 0.OOOE+000 1.224E-005 1.224E-005 Co-58 1.229E-005 8.321E-006 2.544E-004 2.750E-004 Co-60 3.525E-005 4.804E-005 5.489E-004 6.322E-004 Cr-51 O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 Cs-137 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Fe-55 1.578E-004 3.129E-004 1.055E-003 1'.52'6E-003 Fe-59 O.OOOE+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 H-3 4.379E+000 7.036E+000 5.163E+001 6.305E+001 Mn-54 O.OOOE+000 0.OOOE+000 9.505E-005 9.505E-005 Nb-95 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Sb- 125 2.728E-005 3.105E-004 1.504E-003 1.842E-003 Sr-89 o.OOOE+000 0.OOOE+000 O.OOOE+000 0.OOOE+000 Sr-90 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Xe-133 O.OOOE+000 0.OOOE+000 3.817E-005 3.817E-005 Xe-135 o.OOOE+000 O.OOOE+000 3.477E-006 3.477E-006 Total 4.3 80E+000 7.036E+000 5.164E+001 6.305E+001 Page 41 of 63

TABLE 3.2B Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases April May June Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 8.258E-003 6.049E-003 1.804E-003 1.611E-002 Avg. Conc.

([tCi/ml) 5.360E-009 4.266E-009 2.054E-009 Tritium Total Release (Ci) 2.609E+001 1.185E+001 1.491E+000 3.944E+001 Avg. Conc.

(jtCi/ml) 1.694E-005 8.359E-006 1.698E-006 Dissolved Gases Total Release (Ci) 1.027E-004 O.OOOE+000 O.OOOE+000 1.027E-004 Avg. Conc.

([tCi/ml) 6.665E-01 1 O.OOOE+000 O.OOOE+000 Gross Alpha Activity Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.

(ýtCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released (liters) 1.849E+005 1.022E+005 3.729E+004 3.244E+005 Volume of Dilution Water (liters) 1.540E+009 1.418E+009 8.781E+008 3.836E+009 Page 42 of 63

TABLE 3.2B (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases Isotope (Ci) April May June Total Ag-li0m 1.698E-004 3.198E-005 4.072E-005 2.425E-004 Alpha O.OOOE+000 0.00OE+000 o.OOOE+000 O.OOOE+000 Ar-41 O.OOOE+000 0.000E+000 0.OOOE+000 0.OOOE+000 Co-58 8.928E-004 1.992E-003 4.411E-004 3.326E-003 Co-60 9.724E-004 1.351E-004 1.195E-004 1.227E-003 Cr-51 1.535E-004 5.186E-004 0.OOOE+000 6.721E-004 Cs-137 9.991 E-007 O.OOOE+000 O.OOOE+000 9.991E-007 Fe-55 5.472E-003 3.026E-003 1.104E-003 9.602E-003 Fe-59 2.682E-004 2.488E-004 5..727E-005 5.742E-004 H-3 2.609E+00 1 1.185E+001 1.49 1E+000 3.944E+00 1 Mn-54 3.283E-004 3.329E-005 o.OOOE+000 3.616E-004 Nb-95 O.OOOE+000 6.344E-005 4.154E-005 1.050E-004 Sb-125 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Sr-89 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Sr-90 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Xe-133 1.027E-004 0.000E+000 O.OOOE+000 1.027E-004 Xe-135 O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 Total 2.610E+001 1.186E+001 1.493E+001 3.945E+001 Page 43 of 63

TABLE 3.2C Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases July August September Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 1.199E-003 1.485E-004 1.864E-004 1.534E-003 Avg. Conc.

(ýLCi/ml) 2.782E-0 10 3.382E-010 4.428E-010 Tritium Total Release (Ci) 1.430E+001 6.919E-001 2.53 1E+000 1.753E+001 Avg. Conc.

([ICi/ml) 3.318E-006 1.576E-006 6.013E-006 Dissolved Gases Total Release (Ci) 0.OOOE+000 0.000E+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

(jtCi/ml) 0.OOOE+000 0.OOOE+000 0.OOOE+000 Gross Alpha Activity Total Release (Ci) 0.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

(PCi/ml) 0.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released (liters) 2.304E+005 3.372E+004 3.925E+004 3.034E+005 Volume of Dilution Water (liters) 4.31 OE+009 4.391E+008 4.209E+008 5.170E+009 Page 44 of 63

TABLE 3.2C (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases Isotope (Ci) July August September Total Ag-110m 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Alpha o.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Ar-41 O.OOOE+000 o.OOOE+000 0.000E+000 0.OOOE+000 Co-58 6.524E-004 5.506E-005 1.071E-004 8.146E-004 Co-60 8.122E-005 2.532E-005 0.OOOE+000 1.065E-004 Cr-51 O.OOOE+000 o.OOOE+000 0.OOOE+000 0.OOOE+000 Cs-137 0.OOOE+000 O.OOOE+000 0.000E+000 0.OOOE+000 Fe-55 4.655E-004 6.811E-005 7.928E-005 6.1129E-004 Fe-59 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 11-3 1.430E+001 6.919E-001 2.531E+000 1.753E+001 Mn-54 0.OOOE+000 0.OOOE+000 0.000E+000 0.000E+000 Nb-95 0.OOOE+000 O.OOOE+000 0.000E+000 0.000E+000 Sb-125 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Sr-89 o.OOOE+000 0.OOOE+000 0.OOOE+000 0.000E+000 Sr-90 o.OOOE+000 0.OOOE+000 0.000E+000 0.OOOE+000 Xe-133 0.OOOE+000 0.OOOE+000 0.000E+000 0.000E+000 Xe- 135 O.OOOE+000 0.OOOE+000 0.000E+000 0.OOOE+000 Total 1.430E+001 6.920E-00 1 2.531E+000 1.753E+001 Page 45 of 63

TABLE 3.2D Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases Gross Radioactivity October November December Total I

Total Release Excluding H3 I

and Dissolved Gases (Ci) 0.OOOE+000 1.327E-004 4.432E-004 5.760E-004 Avg. Cone.

([tCi/ml) 0.OOOE+000 1.223E-010 2.141E-0 10 Tritium Total Release (Ci) 4.632E+000 1.234E+001 2.206E+001 3.904E+00 1 Avg. Cone.

([LCi/ml) 5.872E-006 1.137E-005 1.065E-005 Dissolved Gases Total Release (Ci) 0.000E+000 0.OOOE+000 0.000E+000 0.00OE+000 Avg. Cone.

(ýICi/ml) 0.OOOE+000 0.OOOE+000 0.000E+000 Gross Alpha Activity Total Release (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Cone.

(ýICi/ml) 0.OOOE+000 0.OOOE+000 0.000E+000 Volume of Waste Released (liters) 3.531E+004 6.889E+004 1.435E+005 2.477E+005 Volume of Dilution Water (liters) 7.888E+008 1.086E+009 2.070E+009 3.945E+009 Page 46 of 63

TABLE 3.2D (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Batch Releases Isotope (Ci) October November December Total Ag-ll10m O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Alpha 0.00OE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Ar-41 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.000E+000 Co-58 0.OOOE+000 9.382E-005 3.198E-004 4.136E-004 Co-60 0.OOOE+000 3.893E-005 0.000E+000 3.893E-005 Cr-51 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Cs-137 O.OOOE+000 *.OOOE+000 O.OOOE+000 o.OOOE+000 Fe-55 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Fe-59 0.OOOE+000 0.000E+000 10.000E+000 0.OOOE+000 H-3 4.632E+000 1.234E+001 2.206E+001 3.904E+001 Mn-54 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Nb-95 O.OOOE+000 O.000E+000 0.OOOE+000 0.OOOE+000 Sb-125 O.OOOE+000 O.OOOE+000 1.234E-004 1.234E-004 Sr-89 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Sr-90 o.OOOE+000 0.00OE+000 0.OOOE+000 0.00OE+000 Xe-133 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Xe-135 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.000E+000 Total 4.632E+000 1.234E+001 2.206E+001 3.904E+00 1 Page 47 of 63

TABLE 3.3A Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases January February March Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 0.000E+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

([.Ci/ml) 0.OOOE+000 0.000E+000 0.OOOE+000 Tritium O.OOOE+/-O0O Total Release (Ci) 0.OOOE+000 0.000E+000 0.OOOE+/-000 0.OOOE+000 Avg. Conc.

(ýLCi/ml) 0.OOOE+000 0.000E+000 0.OOOE+/-000 Dissolved Gases Total Release (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

(PCi/ml) 0.OOOE+000 0.OOOE+000 0.OOOE+000 Gross Alpha Activity Total Release (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

([LCi/ml) 0.OOOE+000 0.OOOE+000 0.OOOE+000 Volume of Waste Released (liters) 7.062+006 6.421E+006 9.165E+006 2.265E+007 Volume of Dilution Water (liters) 5.050E+0 10 3.078E+010 6.OOOE+010 1.413E+01 1 Page 48 of 63

TABLE 3.3A (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases Isotope (Ci) January February March Total Alpha O.OOOE+000 o.OOOE+000 O.OOOE+000 0.00OE+000 Fe-55 0.00013+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 H-3 O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+/-000 Sr-89 O.OOOE+O00 O.OOOE+000 O.OOOE+000 0.OOOE+O000 Sr-90 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total O.OOOE+O( )0 O.OOOE+O( )0 O.OOOE+OC )0 .OOOE+000 Page 49 of 63

TABLE 3.3B Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases April May June Tc )tal Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+000 0.000E+000 Avg. Conc.

([ICi/ml) O.OOOE+000 0.OOOE+000 O.OOOE+000 Tritium Total Release (Ci) 0.OOOE+000 O.OOOE+000 5.832E-003 5.832E-003 Avg. Conc.

(RCi/ml) 0.OOOE+000 O.OOOE+000 7.232E-01 1 Dissolved Gases Total Release (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

([iCi/ml) O.OOOE+000 O.OOOE+000 0.OOOE+000 Gross Alpha Activity Total Release (Ci) 0.OOOE+000 O.OOOE+000 0.OOOE+000 0.000E+000 Avg. Conc.

(PCi/ml) 0.OOOE+000 0.OOOE+000 0.OOOE+000 Volume of Waste Released (liters) 1.31 1E+007 5.797E+006 6.069E+006 2.497E+007 I

Volume of Dilution Water (liters) 1.846E+010 5.511E+010 8.063E+010 1.542E+01 1 Page 50 of 63

TABLE 3.3B (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases Isotope (Ci) April May June Total Alpha O.OOOE+000 O.OOOE+000 o.OOOE+000 O.OOOE+000 Fe-55 O.OOOE+000 0.00OE+000 O.OOOE+000 O.OOOE+000 H-3 O.OOOE+000 0.OOOE+000 5.832E-003 5.832E-003 Sr-89 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Sr-90 O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 Total O.OOOE+000 O.OOOE+000 5.832E-003 5.832E-003 Page 51 of 63

TABLE 3.3C Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases July August September Total Gross Radioactivity Total Release I Excluding H3 and Dissolved Gases (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Cone.

([ICi/ml) O.000E+000 0.000E+000 0.OOOE+000 Tritium Total Release (Ci) 2.583E-002 1.890E-002 3.501E-002 7.975E-002 Avg. Cone.

([ICi/ml) 4.167E-0 10 3.134E-010 4.576E-010 Dissolved Gases Total Release (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

( 1 iCi/ml) O.OOOE+000 0.00OE+000 0.OOOE+000 Gross Alpha Activity Total Release (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

(jiCi/ml) O.OOOE+000 0.OOOE+000 0.00OE+000 Volume of Waste Released (liters) 5.786E+006 4.242E+006 7.089E+006 1.712E+007 Volume of Dilution Water (liters) 6.200E+0 10 6.031+010 7.650E+010 1.988E+01 1 Page 52 of 63

TABLE 3.3C (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases Isotope (Ci) July August September Total Alpha O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Fe-55 O.OOOE+000 0.OOOE+000 0.OOOE+000 O.OOOE+000 H-3 2.583E-002 1.890E-002 3.501E-002 7.975E-002 Sr-89 O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 Sr-90 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total 2.583E-002 1.890E-002 3.501E-002 7.975E-002 Page 53 of 63

TABLE 3.3D Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases Octolber November December Tc tal Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 0.OOOE+000 O.OOOE+000 0.00OE+000 0.OOOE+000 Avg. Conc.

(ptCi/ml) 0.OOOE+000 0.OOOE+000 0.OOOE+000 Tritium Total Release (Ci) 4.095E-002 3.702E-002 5.339E-002 1.314E-001 Avg. Conc.

(p.Ci/ml) 6.501E-010 6.13 6E-010 1.152E-009 Dissolved Gases Total Release (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.

(pýCi/ml) 0.OOOE+000 O.OOOE+000 0.OOOE+000 Gross Alpha Activity Total Release (Ci) 0.000E+000 0.000E+000 0.000E+000 0.000E+/-000 Avg. Conc.

(PCi/ml) 0.OOOE+000 O.000E+000 0.OOOE+000 Volume of Waste Released (liters) 6.204E+006 5.650E+006 8.138E+006 1.999E+007 Volume of Dilution Water (liters) 6.299E+0 10 6.032E+010 4.635E+010 1.697E+01 1 Page 54 of 63

TABLE 3.3D (Con't)

Annual Radioactive Effluent Release Report 2008 Liquid Effluents - Continuous Releases Isotope (Ci) October November December Total Alpha O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Fe-55 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 H-3 4.095E-002 3.702E-002 5.339E-002 1.314E-001 Sr-89 0.OOOE+000 0.000E+000 0.OOOE+000 0.OOOE+000 Sr-90 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Total 4.095E-002 3.702E-002 5.339E-002 1.314E-001 Page 55 of 63

I Table 3.4 Annual Radioactive Effluent Report 2008 I

Dose from Liquid Effluents The dose to a member of the public from total liquid radioactive releases for each quarter was below I

the ODCM limits of 1.5 mrems to the total body and less than or equal to 5 mrems to any organ.

Additionally, the dose to a member of the public from total liquid radioactive releases for the year was below the ODCM limits of 3 mrems to the total body and less than or equal to 10 mrems to any organ.

I Instantaneous release concentrations are limited by the individual radionuclide concentrations I established in 10 CFR 20, Appendix B, for unrestricted areas. During the report period, none of the isotopes released exceed the concentrations specified in Appendix B. The following offsite doses were calculated using equation 1.5 from the Kewaunee ODCM. I Organ 1st Qtr Dose Dose Total Quarterly Limit Percent of Limit I

mRem mRem Total Body 5.408E-004 1.5 3.606E-02 I

Bone 7.716E-005 5.0 1.543E-03 Liver Thyroid 5.976E-004 4.526E-004 5.0 5.0 1.195E-02 9.053E-03 I

Kidney 5.010E-004 5.0 1.002E-02 Lung GI-LLI 4.808E-004 7.234E-004 5.0 5.0 9.616E-03 1.447E-02 I

Organ Dose Quarterly Percent 2nd Qtr Dose Total Limit of Limit mRem mRem I

Total Body Bone 2.399E-004 4.912E-005 1.5 5.0 1.599E-02 9.824E-04 I Liver 2.666E-004 5.0 5.331E-03 Thyroid Kidney 2.092E-004 2.135E-004 5.0 5.0 4.183E-03 4.270E-03 I

Lung 2.281E-004 5.0 4.562E-03 GI-LLI 4.480E-004 5.0 8.959E-03 I I

I Page 56 of 63 I

I

Table 3.4 (Con't)

Annual Radioactive Effluent Report 2008 Dose from Liquid Effluents Organ Dose Quarterly Percent 3rd Qtr Dose Total Limit of Limit mRem mRem Total Body 6.735E-005 1.5 4.490E-03 Bone 4.469E-006 5.0 8.939E-05 Liver 6.835E-005 5.0 1.367E-03 Thyroid 6.414E-005 5.0 1.283E-03 Kidney 6.414E-005 5.0 1.283E-03 Lung 6.588E-005 5.0 1.318E-03 GI-LLI 8.798E-005 5.0 1.760E-03 Organ Dose Quarterly Percent 4th Qtr Dose Total Limit of Limit mRem mRem Total Body 1.832E-004 1.5 1.221E-02 Bone 1.649E-008 5.0 3.298E-07 Liver 1.823E-004 5.0 3.646E-03 Thyroid 1.816E-004 5.0 3.633EB-03 Kidney 1.816E-004 5.0 3.633E-03 Lung 1.816E-004 5.0 3.633E-03 GI-LLI 1.953E-004 5.0 3.907E-03 Calculated Dose This Year Organ Dose Quarterly Percent Total Limit of Limit mRem mRem Total Body 1.041E-003 3.0 3.468E-02 Bone 1.708E-004 10.0 1.708E-03 Liver 1.156E-003 10.0 1.156E-02 Thyroid 9.492E-004 10.0 9.492E-03 Kidney 9.667E-004 10.0 9.667E-03 Lung 1.016E-003 10.0 1.016E-02 GI-LLI 4.190E-003 10.0 4.190E-02 Page 57 of 63

I 3.5 GROUND WATER MONITORING Sample Point I

MW-0706 I

AB-707 AB-708 10/30/2008 10/30/2008

<500

<500 None Detected None Detected I AB-709 10/29/2008 <500 None Detected AB-710 AB-711 10/30/2008 10/30/2008

<500

<500 None Detected None Detected I

AB-712 10/29/2008 <500 None Detected AB-715 AB-717 10/30/2008 10/29/2008

<500

<500 None None Detected Detected U

Settling Plug B Settling Plug C Inner Settling Plug C Outer 06/30/2008 06/30/2008 06/30/2008

<500

<500 515 None None Detected Detected I None Detected Settling Plug G Inner Settling Plug G Outer 06/30/2008 06/30/2008

<500 1510 None None Detected Detected I Settling Plug B 09/19/2008 <500 None Detected Settling Plug C Inner Settling Plug C Outer 09/19/2008 09/19/2008

<500

<500 None None Detected Detected I

Settling Plug G Inner 09/19/2008 <500 None Detected Settling Plug G Outer Settling Plug H Inner 09/19/2008 09/19/2008 3450

<500 None None Detected Detected I

Settling Plug B Inner Settling Plug B Outer 12/03/2008 12/03/2008

<500 2360 None None Detected Detected I Settling Plug C Inner 12/03/2008 <500 None Detected Settling Plug C Outer Settling Plug G Outer 12/03/2008 12/03/2008 6080 2.61E-07 None Detected I

MW-0701 06/25/2007 <500 <1.OE-7 MW-0702 MW-0703 06/28/2007 06/28/2007

<500

<500

<1.OE-7

<l.OE-7 U

MW-0704 MW-0705 MW-0706 06/29/2007 06/25/2007 06/26/2007

<500

<500

<500

<l.OE-7

<1.OE-7

<1.OE-7 I

AB-707 AB-708 06/26/2007 06/27/2007

<500

<500

<1.OE-7

<l.OE-7 I AB-709 #1 06/26/2007 <500 <l.OE-7 AB-709 #2 AB-710 06/27/2007 06/26/2007

<500 <l.OE-7 I

AB-711 06/26/2007 <500 <1.OE-7 AB-712 AB-715 06/26/2007 06/27/2007

<500

<500

<1.OE-7

<1.OE-7 I

Page 58 of 63 I I

Sample Point AB-717 06/27/2007 <500 <1.OE-7 Settling Plug B-inner 08/25/2006 5272 None Detected Settling Plug B-outer 08/25/2006 5516 None Detected Settling Plug C-inner 08/25/2006 4048 None Detected Settling Plug C-outer 08/25/2006 16340 None Detected Settling Plug A 08/10/2006 None Detected Settling Plug A 08/05/2006 96330 102111 Settling Plug B 08/05/2006 <LLD None Detected 275 Settling Plug C 08/05/2006 <LLD None Detected <246 Settling Plug E 08/05/2006 8656 None Detected 8807 Settling Plug G 08/05/2006 <LLD None Detected 1793 Settling Plug A 08/05/2006 101800 Settling Plug B 08/05/2006 <LLD Settling Plug C 08/05/2006 <LLD Settling Plug E 08/05/2006 9287 Settling Plug G 08/05/2006 <LLD Settling Plug A 08/05/2006 102500 Settling Plug B 08/05/2006 <LLD Settling Plug C 08/05/2006 8101 Settling Plug E 08/05/2006 13970 Settling Plug G 08/05/2006 6187 IFISI well S-1 05/24/2006 <LLD IFISI well S-5 05/24/2006 <LLD IFISI well S-9 05/24/2006 <LLD IFISI well MW-4 05/24/2006 <LLD IFISI well S-5 04/05/2006 <LLD IFISI well MW-4 04/05/2006 <LLD Settling Plug C 01/11/2006 <LLD None Detected Settling Plug G 01/11/2006 <LLD None Detected Settling Plug C 01/10/2006 <LLD None Detected Settling Plug G 01/10/2006 <LLD None Detected Settling Plug B 01/10/2006 5081 Settling Plug C 01/10/2006 <LLD Settling Plug D 01/10/2006 4248 Settling Plug G 01/10/2006 3903 Settling Plug B 10/31/2005 <LLD None Detected Settling Plug C 10/31/2005 <LLD None Detected Settling Plug D 10/31/2005 <LLD None Detected Settling Plug G 10/31/2005 <LLD None Detected Settling Plug A Oct-04 110000 Page 59 of 63

4.0 UNPLANNED RELEASES No unplanned releases were made from the Kewaunee Plant during the report period.

5.0 METEOROLOGICAL DATA See Appendix A for missing meteorological data and the joint frequency distribution tables.

6.0 SOLID WASTE DISPOSAL Table 6.1 is a summation of solid wastes shipped during 2008. Presented are the types of wastes, major nuclide composition and disposition of the wastes. Table 6.1 contains the radionuclide content (curies) and percent abundance for each type of waste.

Page 60 of 63

Table 6.1 Annual Radioactive Effluent Report 2008 Solid Waste and Irradiated Fuel Shipments A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL

1. Type of Waste Ci
a. Resins, Filters and Evap Bottoms 3.44E+01 2.44E+00
b. Dry Active Waste (DAW) 1.01E-01 8.38E+01
c. Irradiated Components 0.OOE+00 0.OOE+00
d. Other Waste 0.OOE+00 0.OOE++/-0
2. Estimate of Major Nuclide by Composition
a. Resins, Filters and Evap Bottoms Nuclide  % Abundance Ci H-3 0.038 1.31E-02 C-14 0.007 2.53E-03 Cr-51 0.944 3.24E-01 Mn-54 3.863 1.33E+00 Fe-55 28.226 9.70E+00 Fe-59 0.252 8.67E-02 Co-57 0.034 1.17E-02 Co-58 38.499 1.32E+01 Co-60 10.685 3.67E+00 Ni-63 10.266 3.53E+00 Zn-65 0.579 1.99E-01 Zr-95 0.918 3.15E-01 Nb-95 2.522 8.66E-01 Tc-99 0.618 2.12E-01 Ag-il0m 1.672 5.75E-01 Sb- 125 0.563 1.94E-01 Cs-137 0.021 7.12E-03 Ce-144 0.290 9.98e-02 U-233 0.000 9.38E-05 U-238 0.000 5.9 1E-05 Pu-238 0.001 2.50E-04 Am-241 0.000 6.10E-05 Page 61 of 63

I

b. Dry Active Waste (DAW)

Nuclide  % Abundance Ci I

H-3 C-14 0.524 0.520 5.3 1E-04 5.26E-04 I Cr-51 0.548 5.54E-04 Mn-54 Fe-55 3.394 31.654 3.44E-03 3.20E-02 I Fe-59 0.100 1.01E-04 Co-57 Co-58 0.092 34.441 9.34E-05 3.49E-02 I Co-60 8.072 8.17E-03 Ni-63 Zn-65 11.448 0.195 1.16E'02 1.97e-04 I

Zr-95 0.468 4.74e-04 Nb-95 Tc-99 0.900 0.603 9.1 le-04 6.1OE-04 I

Ag-110m 5.594 5.66E-03 Sb-125 Cs-137 0.634 0.263 6.42e-04 2.66e-04 I

Ce-144 0.548 5.55e-04 Pu-238 Pu-239 0.001 0.000 1.42E-06 4.53e-07 I

c. Irradiated Components Nuclide  % Abundance Ci I

None N/A N/A I

d. Other Waste Nuclide None

% Abundance N/A Ci N/A I

3. Solid Waste Disposition I

Date of Shipment Mode of Transportation Destination 03/18/08 05/20/08 Hittman Transport Hittman Transport Duratek Inc.

Barnwell Disposal Facility I

12/09/08 Hittman Transport Clive Disposal Facility (Bulk)

I B. IRRADIATED FUEL SHIPMENTS No irradiated fuel shipments were made from the Kewaunee Nuclear Power Plant during 2008.

I I

Page 62 of 63 I I

7.0 PROGRAM REVISIONS In accordance with Technical Specifications 6.18.b.3 and 6.19.a, the revisions to the Process Control Program, Offsite Dose Calculation Manual and radioactive waste treatment systems are listed below.

7.1 Offsite Dose Calculation Manual The Offsite Dose Calculation Manual (ODCM) has not been revised during this report period.

7.2 Major Changes to the Radioactive Liquid, Gaseous and Solid Waste Treatment Systems Major changes to the radioactive liquid, gaseous or solid waste systems are submitted in the annual Updated Final Safety Analysis Report consistent with Technical Specification 6.19.

8.0 REPORTABLE OCCURRENCES No reportable occurrences in 2008.

The Event Notification Worksheet 2006 is being included because all the ground water results prior to 2008 are included in this report.

Page 63 of 63

Appendix A Kewaunee Power Station Meteorological Data

Appendix A Kewaunee Power Station.

2008 Meteorological Data Missing Data First Quarter: 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> Second Quarter: 344.0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> Third Quarter: 114.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br /> Fourth Quarter: 1.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br /> Note: A total of 461 hours0.00534 days <br />0.128 hours <br />7.622354e-4 weeks <br />1.754105e-4 months <br /> of data is missing or otherwise unavailable. This represents the availability of 94.75% of the data for the year.

APPENDIX A Annual Radioactive Effluent Release Report 2008 FIRST QUARTER 2008 3 Stability Class A Total Hours Missing = 1.5 Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

N NNE 0

0 0.75 0 3.75 1.25 21.5 22 15.25 23.75 10.75 0 0 3.75 40.5 62.25 I NE 0 0 9.75 40.75 10.5 0 0 61 ENE E

0 0

0,25 2.25 7.5 7.5 13.25 10.25 9.5 4.25 0

0 0

0 30.5 24.25 I ESE 0 0.75 8.5 7.5 1.75 0.25 0 18.75 SE SSE 0

0 1.25 1.5 4.25 1.75 19.25 6.25 15.5 18.25 0.25 9.5 0

0 40.5 37.25 I

S 0 1 11.75 18.25 8 0.75 0 39.75 SSW SW 0

0 0.25 2

26.75 35.25 24.25 12.75 4.75 1 0 0

0 0

52.25 54.75 I

WSW 0.25 1.75 31 19.5 11.5 0 0 64 W

WNW 0.25 0

1.75 1.75 22.5 19.5 67.75 21.5 23.5 10 9.75 8.5 0.25 0.25 125.75 61.5 I

NW NNW TOTAL 0

0 0.5 0.25 0.25 15.75 11.25 5.5 207.75 25.25 43.25 373.25 10.25 16.25 184 1.25 41 0 0 0

4.25 47 66.5 826.5 I

Stability Class B I

Wind Direction I

CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL a N 0 0.5 2 2 0 0 4.5 Ui NNE 0.25 0 1.75 0.75 1.5 4.25 NE ENE E 0375 0

0 1.25 0.25 2.25 0.25 2.25 1.5 0

0 0

0 0

0 1.5 2.5 4.5 I

ESE SE 0.75 0 0.25 0.25 2.25 1 0.75 0

0.25 0 2.5 3 I SSE 0.25 0 1.75 2.75 0 4.75 S

SSW 0.25 0.75 5.75 15.25 3.5 7.5 2.25 1

0 0

11.75 24.5 I SW 0.75 4.25 2.5 0.75 0.25 8.5 WSW W

0 0

5.75 6

4.75 14.75 1.5 2

4.25 0

16.25 22.75 I

WNW 0 2.25 10 2.25 0 14.5 NW NNW 0.25 0

2.25 1

9.5 7.25 4.5 1

0 0

16.5 9.25 I

TOTAL 4 47.25 72.5 21.5 6.25 151.5 Page A2 of A15 I

I

APPENDIX A Annual Radioactive Effluent Release Report 2008 Stability Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.5 1.25 1 1.25 0 0 4 NNE 0 0 0.5 2.25 2.25 0.25 0 5.25 NE 0 0 1.25 2 0 0 0 3.25 ENE 0 0.25 0.75 2.5 0 0 0 3.5 E 0 0.25 0.75 2 1.25 0 0 4.25 ESE 0 0.5 0.5 2.25 0.25 0 0 3.5 SE 0 0.5 3.25 0.75 1 0 0 5.5 SSE 0 0.5 0.5 0.75 1.5 0 0 3.25 5 0 0 2.5 0.25 0.75 0 0 3.5 SSW 0 0.25 9.25 7.25 0.75 0 0 17.5 SW 0 0 8 2.25 0.75 0 0 11 WSW 0 0.25 5 2.25 5.75 0 0 13.25 W 0 0.25 3.75 13 4.25 0 0 21.25 WNW 0 0 0.75. 8.5 5.25 .0 0 14.5 NW 0 0.75 3 12 2 0 0 17.75 NNW 0 0.25 1.75 8 0.5 0 0 10.5 TOTAL 0 4.25 42.75 67 27.5 0.25 0 141.75 Stability Class D Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.5 5.75 3.5 0.75 0 0 10.5 NNE 0 0 2.25 3.5 1 0 0 6.75 NE 0 0 5 0.25 0.5 0 0 5.75 ENE 0 1.75 6.5 1.25 1 0 0 10.5 E 0 0.75 2.75 2.25 0.75 0.75 0 7.25 ESE 0 1.25 3.5 10.25 3.25 0 0 18.25 SE 0 1.25 5 6 3 0 0 15.25 SSE 0 0.5 1.5 1.5 4.25 0.5 0 8.25 5 0 2 4 15 19.5 1.25 0 41.75 SSW 0.25 0.5 13.25 9 1.25 0 0 24.25 SW 0 1 13.25 11 5.75 1 0 32 WSW 0 1 12.5 19.75 2.5 0 0 35.75

.W 0 2 12.5 46 12 3.25 0 75.75.

WNW 0 0.5 8 23.5 8.5 0 0 40.5 NW 0 0.25 12 30.25 5.25 0 0 47.75 NNW 0 0.25 13.75 19.5 3.75 0 0 37.25 TOTAL 0.25 13.5 121.5 202.5 73 6.75 0 417.5 Page A3 of Al 5

APPENDIX A Annual Radioactive Effluent Release Report 2008 I

Stability Class E I

Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I N 0 0.25 4.5 6.25 0 0 0 11 NNE NE 0

0 0.25 0.25 2.25 2.5 3

0 0

0 0

0 0

0 5.5 2.75 I

ENE 0 1 0.5 0 0 0 0 1.5 E

ESE 0

0 0.25 0.5 0.5 1.75 0.5 1.25 0

0.25 0

0 0

0 1.25 3.75 I

SE 0 0.5 0.25 0.25 0 0 0 1 SSE S

0 0

0 1

1.75 7.75 1.75 10.75 0

0.5 0.5 0.75 0

0 20.75 4 I 5.25 0.25 0 0 27.75 SSW SW WSW 0

0.25 0.25 2.75 3

1 19.25 22 25.75 17.25 19.25 0

0.5 0

0 0

0 42.25 46.75 I

w WNW NW 0

0 0

1.25 1.75 1.25 17.25 9.25 15.75 24.25 19.25 15.5 0

0.25 3.75 0

0 0

0 0

0 42.75 30.5 36.25 I

NNW TOTAL 0

0.5 1

16 16.25 147.25 148.5 0

5.5 0

1.25 0

0 41.25 319 I Stability Class F U Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

N NNE 0

0 0.25 0

1.5 0

0.25 0

0 0

0 0

0 0

2 0 I NE 0 0 0 0 0 0 0 0 ENE E

0 0

1.75 1.5 0.75 0 0 0

0 0

0 0

0 0

1.75 2.25 I ESE 0 0.25 1 0.5 0 0 0 1.75 SE SSE 0

0 0

0 0.5 0.5 0.25 0 0 0

0 0

0 0

0.5 0.75 I

S 0 0.75 7 0 0 0 0 7.75 SSW SW 0

0 1.75 1.5 13.5 17.25 2.25 6.25 0

1.5 0

0 0

0 17.5 26.5 I

WSW 0 2.5 11 7.75 0 0 0 21.25 W 0 0

2.75 1.75 15 17 11 14 0

0 0

0 0

0 28.75 32.75 I

WNW NNW TOTAL 0

0 0 15.75 1

0 13.75 6.75 105.5 5.5 3.75 51.5 0

0 1.5 0

0 0

0 0

0 20.25 10.5 174.25 I

I Page A4 of A15 I

APPENDIX A Annual Radioactive Effluent Release Report 2008 Stability Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.25 0 0 0 0 0.25

~NNE 0 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 0 SSE 0 0 0 0.75 0 0 0 0.75 S 0 0 1.75 0 0 0 0 1.75 SSW 0 0 5.25 1 0 0 0 6.25 SW 0 0 6.5 5.5 0 0 0 12 WSW 0 1 16.5 15 0 0 0 32.5 W 0 3 29.25 13 0 0 0 45.25 WNW 0 3 25.25 5.25 0 0 0 33.5 NW 0 2.5 11.75 0 0 0 0 14.25 NNW 0 0.75 4.5 0.25 0 0 0 5.5 TOTAL 0 10.25 101 40.75 0 0 0 152 2 nd QUARTER 2008 Stability Class A Total Hours Missing = 344 Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 1..5 6.25 8.25 0.5 0 16.5 NNE 0 0 7 19 25.5 29.25 0 80.75 NE 0 0.25 14.25 15.75 2.5 0 0 32.75 ENE 0 0 13.75 2.25 0 0 0 16 E 0 0 12.75 0.25 0 0 0 13 ESE 0 0 8 0 0 0 0 8 SE 0 0 8 1.75 0 0 0 9.75 SSE 0 0 4.75 8 7.5 1.25 0 21.5 S 0 0 1.5 10.25 3.75 0 0 15.5 SSW 0 0 1 4.25 0 0 0~ 5.25 SW 0 0 2.75 13 3.25 5.75 0 24.75 WSW 0 0 4.75 26.75 9 1.5 0 42 W 0 0.5 4.5 14 3 0 0 22 WVNW 0 0 7.25 15.75 9.25 0 0 32.25 NW 0 0.25 6 14 9 0 0 29.25 NNW 0 0 1.75 17.5 12.5 0 0 31.75 TOTAL 0 1 99.5 168.75 93.5 38.25 0 401 Page AS of A15

APPENDIX A 3 Annual Radioactive Effluent Release Report 2008 Stability Class B I

Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

N 0 0.5 0.5 1 0 0 2 NNE NE 0.25 0 1.5 1.5 3.25 1.75 7.75 0

1.75 0

0 0

14.25 3.5 I

ENE E

0 0

0 0.5

.1 0.75 0.25 0

0 0.5 0

0 0

0 0

0 0

0 1.25 0.75 1 I ESE SE SSE 0

0 0.75 1 0 0.5 0

1 0

0 0

0 2.25 1

I S 0 0.5 3.5 0.75 0 0 4.75 SSW SW 0

0 0.75 0

0.25 1.25 0

1 0

0 0

0 2.25 1

I WSW 0 0.5 2.5 0.25 1 0 4.25 WNW W 0.25 0

1 0

1.5 0.5 0.75 0.5 0

0 0

0 3.5 1

I NW 0 0.5 1.25 1.25 0 0 3 NNW TOTAL 0

0.5 0.25 11 20 3

16.75 2 0 2.75 0

0 5.25 51 I

Stability Class C I Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL U

N NNE 0

0 0

0 0.75 3.25 5.75 1 3.25 11 0

1 0

0 5

21 I

NE 0 0 1 4.25 2 0 0 7.25 ENE E

0 0

0 0

2.5 0.75 0.25 1 0.5 0

0 0

0 0

4 1

I ESE 0 0.25 2 0.25 0 0 0 2.5 SE SSE 0

0 0

0 1.5 1

0.75 1 0.75 0

0.25 0 0 0

2.25 3

I 2.25 4.5 SSW SW S 0 0

0 0

0 0

0.75 1.25 0.5 1.25 1.5 1.5 1.25 0

0 0

0 0

0 0

2.5 3.25 I

WSW W

0 0

0 0 0.25 1 1.75 1.75 1.25 1.25 0.25 0

0 0

4.25 3.25 I WNW 0 0 0.25 2 1.5 0 0 3.75 NW NNW 0

0 0

0 1.25 0.5 3.25 1.5 0.75 1.75 0

0 0

0 5.25 3.75 I TOTAL 0 0.25 18.5 29.5 26.75 1.5 0 76.5 I

Page A6 of A15 I

APPENDIX A Annual Radioactive Effluent Release Report 2008 Stability Class D Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.25 2 .2 2.75 0 0 7 NNE 0 0.25 7 24.75 18.5 4.5 0 55 NE 0 1.5 14, 6 0.5 0 0 22 ENE 0 .0.25 6.5 4.5 1.5 0 0 12.75 E 0 0.5 7.25 1.75 0.5 0 0 10 ESE 0 1 5 1.75 0 0 0 7.75 SE 0 0.25 3.25 .2 0 0 0 5.5 SSE 0 0 5.25 8.25 12.5 2.25 0 28.25 S 0 0.25 8 17 7 0 0 32.25 SSW 0 0 7.75 6.25 0 *0 0 14 SW 0 0.25 1.5 3.75 3.75 0 0 9.25 WSW 0 0.5 3 5.25 5.25 3 0 17 W 0 0.75 1.75 1.75 0 0 0 4.25 WNW 0 0 1.75 4 1.5 0 0 7.25 NW 0 0.5 4.25 7 6.25 0 0 18 NNW 0 0 6.25 7.25 6 0 0 19.5 TOTAL 0 6.25 84.5 10125 66 9.75 0 269.75 Stability Class E Wind Direction ICALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 1.75 2.5 2.75 4.25 0 0 11.25 NNE 0.75 12.75 15.5 8.25 6.5 0.25 44 NE 3 14.25 6 1.5 0 0 24.75 ENE 4.5 8.25 0.75 0 0 0 13.5 E 3.75 7.5 0.5 0 0 0 11.75 ESE 6.25 10 0.5 0 0 0 16.75 SE 1.75 10.25 1.25 0 0 0 13.25 SSE 2.25 8.5 7.25 3.75 0.5 0 22.25 S. 3.25 20 30.25 2.25 0.25 0 56 SSW 1 14.75 14 0.75 0 0 30.5 SW 1.75 8 7 1.75 0.25 0 18.75 WSW 0.75 6.75 2.75 3.25 0 0 13.5 W 0.75 10.75 7.25 0 0 0 18.75 WNW 2 5.5 6 0 0 0 13.5 NW 0.75 4.5 5 0.25 0 0 10.5 NNW 1 5.5 1.5 3.5 0 0 11.5 TOTAL 35.25 149.75 108.25 29.5 7.5 0.25 330.5 Page A7 of A15

APPENDIX A Annual Radioactive Effluent Release Report 2008 I

Stability Class F I

Wind Direction N

CALM 0

1-3 1.5 4-7 5.25 8-12 0.25 13-18 1.25 19-24 0

>24 0

TOTAL 8.25 I

NNE NE ENE 0

0 0

0.75 1.75 3

6.75 7.75 3.5 4.25 1.5 1

0 0

1 0

0 0

0 0

0 11.75 11 8.5 I

E ESE 0

0 0

2.25 1.75 1.75 3.75 0.25 0

1.75 0

0 0.5 0.25 0

0 0

0 0

4 6 I SE 2.75 5.75 10.75 SSE S

0 0

3.75 4

12 17 9.75 11.75 3.25 1.5 0

0 0

0 28.75 34.25 I SSW 0 2.5 21.5 7.5 0.5 0 0 32 SW WSW 0

0 3.75 1

8.75 17.75 9.5 7

0.25 0.5 0

0 0

0 22.25 26.25 I

W 0 1.25 14.75 2.25 0 0 0 18.25 WNW NW 0

0 1.5 2.25 10.5 11.75 2.5 2.25 0

0 0

0 0

0 14.5 16.25 I

NNW 0 1.75 7.75 0;25 0.75 0 0 10.5 TOTAL 0 35.5 156.25 61.75. 9.5 0.25 0 263.25 I Stability Class G I Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

N 0 1.5 6 0.75- 0 0 0 8.25 NNE NE 0

0 2.75 2.75 6.5 4.75

.3 1.5 0

0 0

0 0

0 12.25 9

U 0 7.5 ENE E

ESE 0

0 0

0.75 2.25 0.5 6.5 4.5 8

0.25 0.25 1.75 2.25 0

0 0.25 0

0 0 0 12.75 7 I SE SSE S

0 0

0 1.5 2.25 1.75 15.25 48.25 34.25 5.25 44.25 19.75 1.25 9

1 0.25 0.25 0

0.5 0.5 0

24 104.5 56.75 I

SSW SW 0

0 2.5 5.5 28.75 35 33.5 4.25 5.5 3.75 0

0 0

0 0

0 0

0 35.5 46 38.75 I

WSW 0 1.5 0 WNW W 0 0

3.25 2.75 28 9

9.75 4.5 0

0 0

0 0

0 41 16.25 I NW 0 1.5 9.5 3 0 0 0 14 NNW TOTAL 0

0 37 4

286.75 9 1.5 109 13.5 0 0 0.75 0

1 14.5 448 I

Page A8 of A15 U

I

APPENDIX A Annual Radioactive Effluent Release Report 2008 3rd QUARTER 2008 Stability Class A Total Hours Missing 114.25 Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.5 13.25 20.5 0.75 0 0 35 NNE 0 0 16 27.25 14 0.25 0 57.5 NE 0 1 31.75 10.75 0 0 0 43.5 ENE 0 0 20 7.75 0 0 0 27.75 E 0 0 12.5 7.5 0 0 0 20 ESE 0 0 13.25 2 0 0 0 15.25 SE 0 0.5 16 10.5 0 0 0 27 SSE 0 0.75 7.25 31.75 29 0.5 0.25 69.5 S 0 0.25 15.5 20.5 9 1.25 0 46.5 SSW 0 0 3.5 7 0.25 0 0 10.75 SW 0 0 5.5 22.25 1.75 0 0 29.5 WSW 0 0 10.5 37.25 0 0 0 47.75 W 0 0 21.25 31.75 1.75 0 0 54.75 WNW 0 0.5 26.25 16.5 0.5 0 0.25 44 NW 0 1.25 37.25 28.75 0.5 0 0 67.75 NNW 0 0.25 24.25 25.75 2 0 0 52.25 TOTAL 0 5 274 307.75 59.5 2 0.5 648.75 Stability Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 1.25 0.5 0 0 0 1.75 NNE 0 0.25 2.5 3.25 1 0 0 7 NE 0 0 5 3.25 0 0 0 8.25 ENE 0 0 2.25 0.25 0 0 0 2.5 E 0 0 1.5 0 0 0 0 1.5 ESE 0 0 3.25 0.5 0 0 0 3.75 SE 0 0 2 0.25 0 0 0 2.25 SSE 0 0 1 2.75 0.75 0 0 4.5 S 0 0 3.5 2.25 0 0 0 5.75 SSW 0 0 0.75 1 0 0 0 1.75 SW 0 0.25 1 1.75 0 0 0 3 WSW 0 0.25 2 3.5 0 0 0 5.75 W 0 0 1.25 4 0.25 0 0 5.5 WNW 0 0.25 2 3 0 0 0.25 5.5 NW 0 0 2 1.75 0 0 0 3.75 NNW 0 0.25 2 1.25 0 0 0 3.5 TOTAL 0 1.25 33.25 29.25 2 0 0.25 66 Page A9 of A15

APPENDIX A Annual Radioactive Effluent Release Report 2008 I

Stability Class C I Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

NNE N

NE 0

0 0

2.25 12.25 1

7.75 1

7 0.25 0

1 0

0 0

2.25 11 19.25 I

ENE E

0 0

12.75 4.25 1.5 1

0 0

0 0.25 0

0 0

13.75 5.75 6.75 I

ESE 0 6.5 SE SSE 0

0 2.25 7 9.25 3.25 0.25 1

0 0

16.5 6.5 I S 0.25 7.75 3.75 0 0 11.75 SSW SW 0.25 0

1.25 1.25 0.25 0 0 0

0 0

1.5 1.5 I

WSW 0 1.75 4 0 0 5.75 WNW W 0 0

2.5 2.75 3.25 1.75 1.25 1.25 0

0 5.75 7

I NW 0 1.5 1 0 0 2.5 NNW TOTAL 0.5 1

1.25 68.25 0.25 45 5.25 0 0 0 119.5 2 I Stability Class D I

Wind Direction I

CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N

NNE 0

0 0.5 1

1.5 3.25 2.25 12.25 1.25 0.25 0

0 0

0 5.5 16.75 I

0 0 0 18.75 NE ENE E

0 0

0 1.25 0.25 1

14.5 12 5 1.75 3

1.5 0 0

0 0

0 0

14.5 7

I ESE SE SSE 0

0 0

1.5 0.5 1.5 12.75 12.5 10.75 0.5 12.5 15 0.75 0

3 0

0 0

0 0

0 15.5 25.5 30.25 I

SSW S 0 0

2.5 1

9.75 7.5 8.25 1

1.5 0

0 0

0 0

0 0

0 0

20.5 9.5 7.25 I

SW 0 0.25 5.5 WSW W

0 0

1.75 1.5 11.25 8 4.5 5 0 0 0 0 0 0

18 14 I WNW 0 1 5.5 8 0.25 0 0 14.75 NW NNW 0

0 1.25 0.75 3.25 4.25 3.25 0.75 0

0 0

0 0

0 7.75 5.75 I

TOTAL 0 17.5 127.25 81 5.5 0 0 231.25 Page A10 of A15 3

I

APPENDIX A Annual Radioactive Effluent Release Report 2008 Stability Class E Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.75 5.25 2.5 0.25 0 0 8.75 NNE 0 2.25 10 3.75 0 0 0 16 NE 0 0.75 10.5 0.75 0 0 0 12 ENE 0 1.25 2.25 0 0 0 0 3.5 E 0 1.5 3 0 .0 0 0 4.5 ESE 0 0.75 3.25 0.25 0 0 0 4.25 SE 0 4..25 2.5 2.25 0.25 0 0 9.25 SSE 0 3.5 13.75 11.75 9.25 0 0 38.25 S 0 4.5 36.75 8 0.25 0 0 49.5 SSW 0 5.75 17.75 1 0 0 0 24.5 SW 0 2.5 15.5 0.75 0 0 0 18.75 WSW 0 2.25 14.25 6.5 0 0 0 23 W 0 1 16.25 3 0.75 0 0 21 WNW 0 1.75 7.75 3.5 0 0 0 13 NW 0 1.25 8.25 2 0 0 0 11.5 NNW 0 3 6 2.25 0 0 0 11.25 TOTAL 0 37 173 48.25 10.75 0 0 269 Stability Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.5 5.5 0.25. 0 0 0 6.25 NNE 0 0.5 2.5 2.5 0.5 0 0 6 NE 0 1.25 2 0.25 0 0 0 3.5 ENE 0 1.25 1.25 0 0 0 0 2.5 E 0 0.5 0.75 0 0 0 0 1.25 ESE 0 0.75 2.25 0 0 0 0 3 SE 0 1.5 2.75 0.5 0 0 0 4.75 SSE 0 3.25 6.5 10.75 5.5 0 0 26 5 0 3.25 22.75 5.25 0.5 0 0 31.75 SSW 0 5.75 22.25 0.5 0 0 0 28.5 SW 0 3 10.25 0.25 0 0 0 13.5 WSW 0 3.5 30.5 6.75 0 0 0 40.75 W 0 3.5 31.75 0.25 0 0 0 35.5 WNW 0 2 15.5 0.5 0 0 0 18 NW 0 2.75 19.75 0 0 0 0 22.5 NNW 0 2.25 8.25 0.25 0 0 0 10.75 TOTAL 0 35.5 184.5 28 6.5 0 0 254.5 Page All of Al 5

APPENDIX A Annual Radioactive Effluent Release Report 2008 I

Stability Class G I

Wind Direction N

CALM 0

1-3 1.5 4-7 1.5 8-12 0

13-18 0

19-24 0

>24 0

TOTAL 3

I NNE NE ENE 0

0 0

0.75 1.25 1

3.25 4

2.5 0.25 0

0 0

0 0

0 0

0 0

0 0

5 3.5 4.5 U

E ESE SE 0

0 0

1.75 0.5 1.5 1.25 3.5 7

0 0

0.5 0

0 0

0 0

0 0

0 0

3 4

9 I

SSE S

0 0 7.25 2 24 23 30.5 19.5 2.75 0.5 0

0 0

0 59.25 50.25 I SSW 0 9.75 43.75 0.75 0 0 0 54.25 SW WSW 0

0 13.75 10.75 69.25 29 0 1 0 0 0 0

0 0

42.75 81 I

W 0 17.75 52.25 4 0 0 0 74 WNW NW 0

0 15 8.75 37.75 29 0

0 0

0 0

0 0

0 52.75 37.75 I

NNW 0 3.75 17 0 0 0 0 20.75 TOTAL 0 97 348 56.5 3.25 0 0 504.75 I 4 th QUARTER 2008 Stability Class A Total Hours Missing = 1.25 I Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

N 0 0 1.5 4.75 '14 2.75 0 23 NNE NE 0

0 0.25 0.25 4.25 9.5 9.5 12 10.5 6 2 0.25 0

0 22 32.5 I

ENE E

ESE 0

0 0

0.25 0

0 6.75 9

12-6.25 17 23.25 4.5 1.5 15.25 2.25 0

3 0

0 0

19.75 27.75 53.5 I

SE SSE S

0 0

0 0.75 0.25 0

6.5 2.5 17 13.5 11 54.75 50.75 21.25 10.25 4.75 29.25 0.5 4.75 0

0 76.25 69 82.5 I

SSW SW 0

0 0.25 1.75 18.25 15.25 41 19.25 1.5 6.5 0

0 0

0 61 42.75 I WSW 0 2.75 21.5 20.5 16.5 10.25 2.25 73.75 WNW W 0 0

3.75 2.5 38.25 27.5 78.5 60.75 22.5 11.5 14.25 0

3.25 0

160.5 102.25 I

NW 0 1 13.75 50 30 7.75 0 102.5 NNW TOTAL 0

0 0.75 14.5 4.25 207.75 18 440 16.75 239.25 4

81 10.25 0 43.75 992.75 I

Page A12 of A15 I

I

APPENDIX A Annual Radioactive Effluent Release Report 2008 Stability Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.25 0.5 0.75 0 0 0 1.5 NNE 0 0 0 0.25 0.5 0 0 0.75 NE 0 0.25 0.25 0.75 0 0 0 1.25 ENE 0 0 0 1.75 0 0 0 1.75 E 0 0 1.5 0 0 0 0 1.5 ESE 0 0 0.25 0 0.75 0 0 1 SE 0 0 0.25 0.25 0.25 0 0 0.75 SSE 0 0 0.25 0.5 0.25 0.25 0 1.25 S 0 0.25 0.75 8.75 0.5 0 0 10.25 SSW 0 0 8 2.25 0 0 0 10.25 SW 0 0.25 2.25 1.25 0 0.75 0 4.5 WSW 0 0.25 0.5 1.5 1 1.5 0 4.75 W 0 0.5 1.25 7.25 2.75 0.5 0 12.25 WNW 0 1 3.5 10.5 5.75 0.5 0 21.25 NW 0 0.25 2.25 3.75 4.25 0 0 10.5 NNW 0 0 0.75 1 0.25 0 0 2 TOTAL 0 3 22.25 40.5 16.25 3.5 0 85.5 Stability Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.25 0 0 0 0 0.25 NNE 0 0 0.5 0.5 0.25 0 0 1.25 NE 0 0.25 0.5 2.25 0 0 0 3 ENE 0 0 0 0.75 0 0 0 0.75 E 0 0 4.5 0 0 0 0 4.5 ESE 0 0 0.25 0.5 0.25 0 0 1 SE 0 0 1.25 0.5 0 0 0 1.75 SSE 0 0 0 0.25 0.25 0.75 0 1.25 3.5 5 0.75 0 0 9.5 S 0 0.25 SSW 0 0 6.25 2.5 0.25 0 0 9 SW 0 0 1.25 0.75 0.25 1.25 0 3.5 WSW 0 0.5 1.5 2.5 1 0 0 5.5 W 0 0.25 2 .16 7 0 0 25.25 WNW 0 0 3.25 "9.5 3.25 0 0 16 NW 0 .0 1.5 3.75 6 0 0 11.25 NNW 0 0 0.25 .1.25 0.25 0 0 1.75 TOTAL 0 1.25 26.75 46 19.5 2 0 95.5 Page A13 of A15

APPENDIX A Annual Radioactive Effluent Release Report 2008 U

Stability Class D I

Wind Direction N

CALM 1-3 0.25 4-7 1.25 8-12 1.5 13-18 0

19-24 0

>24 0

TOTAL 3

I NNE NE ENE 0

0 0

3.25 3.75 3.25 2.25 2

0.5 1.25 0

0 0

0 0

0 0

0 6.75 5.75 3.75 U

E ESE 0

0

  • 4.5 0.25 1.75 0.75 0 0 0

0 0

0 0

0 0

0 4.5 3.25 1 I SE 0 1.5 SSE S 0.25 0 1.25 13.25 2.75 23.75 2.25 4.25 0.25 0

0 0

6.5 41.5 I SSW 0.25 15.5 18.25 0.75 0 0 34.75 SW WSW 1.25 0.5 10.75 6.25 4

7.5 0.5 0.5 0

0 0

0 16.5 14.75 I W 1.25 13.75 26.75 9 0.25 0 51 WNW NW 1.5 1

18.75 5

22.75 23.75 8.5 10.5 0

0 0

0 51.5 40.25 I

NNW 0 0.5 5.75 0.75 0 0 7 TOTAL 6.25 103 143.75. 38.25 0.5 0 291.75 I Stability Class E I Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I

N 0 0.25 1.75 2.25 0 0 0 4.25 NNE NE 0

0 0

0.5 0.25 4

0.25 0.5 0

0 0

0 0

0 0.5 5

I ENE 0 0.25 1.25 0 0 0 0 1.5 E

ESE 0

0 0.5 1.75 0.5 0.5 0

0 0

0 0

0 0

0 2.25 1 I SE SSE S

0 0

0 0.5 0.25 1.5 1.75 17.5 0 3.5 5.5 10.75 0

9.75 1.25 0

1.5 0

0 0

0 18.75 4

31 I

SSW SW 0

0 4.25 5.5 26.5 16.75 9

4.25 20.25

-0 1.25 0

0 0

0 0

0 0

39.75 27.75 36.5 I

WSW 0 4.75 11.5 W

WNW 0

0 2

1.75 17 9.75 25.75 15.75 2.75 0 0 0

0 0

44.75 30 I NW 0 4.25 16.5 14.75 0 0 0 35.5 NNW TOTAL 0

0 0.25 28.25 7.25 132.75 4.5 117 0.5 15.5 0

1.5 0

0 12.5 295 I

Page A14 of A15 I

I

APPENDIX A Annual Radioactive Effluent Release Report 2008 Stability Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.75 0.5 0 0 0 1.25 NNE C0 0 0.75 0 0 0 0 0.75 NE C) 0.25 2 0 0 0 0 2.25 ENE 0 0.75 0 0 0 0 0 0.75 E 0 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 0 SE C) 1 0 0 0 0 0 1 SSE 0 1 6 6.5 3.75 0.25 0 17.5 S 0 4.5 15 4.5 0 0 0 24 SSW 0 2.5 25.5 1 0 0 0 29 SW 0 4 7.5 0.75 0 0 0 12.25 WSW 0 3 7.5 16.75 0 0 0 27.25 W 0 1.5 14 7.5 0 0 0 23 WNW 0 1 5.75 7 0 0 0 13.75 NW 0 2.5 14.75 1.25 0 0 0 18.5 NNW 0 0.25 5.25 0 0 0 0 5.5 TOTAL 0 22.25 104.75 45.75 3.75 0.25 0 176.75 Stability Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 1.5 1.25 0.25 0 0 0 3 NNE 0 0.25 0.5 0 0 0 0 0.75 NE 0 0.75 0.75 0 0 0 0 1.5 ENE 0 0.75 0 0 0 0 0 0.75 E '0 1.25 0 0 0 0 0 1.25 ESE 0 1 0 0 0 0 0 1 SE 0 3.25 0 0 0 0 0 3.25 SSE 0 2.75 8 8 0 0 0 18.75 S 0 5.75 15.5 2.5 0 0 0 23.75 SSW 0 3.5 25 2 0 0 0 30.5 SW 0 8.5 20.75 0 0 0 0 29.25 WSW 0 4.75 .32.75 5.5 0 0 0 43 W 0 5.5 51.25 1 0 0 0 57.75 WNW 0 3.25 28 1.5 0 0 0 32.75 NW 0 4 10.5 0 0 0 0 14.5 NNW 0 1.25 6.5 0 0 0 0 7.75 TOTAL 0 48 200.75 20.75 0 0 0 269.5 Page A15 ofAl5

Appendix B Kewaunee Power Station Event Notification Worksheet

PAGE 1 OF 2 NRC FORM 361 U.S. NUCLEAR REGULATORY COMMISSION (12-2000) REACTOR PLANT OPERATIONS CENTER EVENT NOTIFICATION WORKSHEET EN # 'LIZ 76,L-NRC OPERATION TELEPHONE NUMBER: PRIMARY -- 301-816-5100 or 800-532-3469", BACKUPS - [1st] 301-951-0550 or 800-449-3694",

[2ndl 301-415-0550 and [3rdl 301-415-0553 "Licensees who maintain their own ETSare provided these telephone numbers.

NOTIFICATION TIME FACILITY OR ORGANIZATION UNIT NAME OF CALLER CALL BACK #

,(4 8 Kewaunee Fower Station N/A David Karst (920) 388-8235 EVENT TIME & ZONE EVENT DATE POWERMv.ODE BEFORE POWERIMODE AFTER 1400 Central 08/10/2006 Operating Operating EVENT CLASSIFICATIONS 1-Hr. Non-Emergency 10 CFR 50.72(b)(1) (v)(A) Safe S/D capability AINA GENERAL EMfERGENCY GEWAAEC TS Deviation ADEV (v)(B) RHR Capablity AINB SITEAREA EMERGENCY SIT/AAEC 4-Hr. Non-EmerqencV 10 CFR 50.72(b)(2) (v)(C) Controlof Rad Release AINC ALERT ALEIAAEC (i) TS Required 5/D ASHU (v)(D) Accident Mitigation AIND UNUSUAL EVENT UNU/AAEC (iv)(A) ECCS Discharge to RCS ACCS (xii) Offsito Medical AMIED 5072 NON-EMERGENCY (see next columns) (Iv)(B) RPS Actuation (scram) ARPS (xiii) Loss Comm/AsmrVResp AOOM PHYSICAL SECURITY (73,71) I V' (xi) Oftsite Notification APRE 60-Day Optional 10 CFR 50.73(a)(1)

MATERIALIEXPOSURE B?.? 8-Hr. Non-Emergency 10 CFR 50.72(b)(3) Invalid Specified Systern Actuation AiNV FITNESS FOR DUTY IfFITr (ii)(A) Degraded Condition ADEG Other Unspecified Requirement (Identify)

OTHER UNSPECIFIED REQMT. (see !ast column) i. t() Unanalyzed Condition AUNA INFORMATION ONLY W'F (Iv)(A) Specified System Actuation AESF NOW DESCRIPTION include: Systems affected, actuations and their initiating signals, causes, effect of event on plant, actions taken or planned. etc. (Conlinue on back)

At 1400 on 8/10/06 KPS is planning on making a notification to the State and Local Government that samples taken at settling plugs in the basement of the Auxiliary Building and Turbine Building show elevated tritium levels. Detected tritium levels were between 6,000 and 103,000 pico curries per liter. The Radiological Effluent Program has not detected any elevated tritium levels outside the plant.

RCS leakage is .19 gpm, stable and within Technical Specification limits and there is currently no identified leakage from the Spent Fuel Pool.

Investigation is continuing to identify the reason for the increase in tritium levels.

/~VIUfce.4&' 1L4_-J4a..'ý6 Cix.'ry,,r~,h T' !, 709ý.fto AV4k 461azot /.)eO/ Zit:-

'a')AT 10c~ C 7- . c-4 %J z)-: -AA 4

- It if)

I-01-l

,) W -* -C c -)ý,J -',,AJ 91--_61C-1,44- 61ýý7Jc'E NOTIFICATIONS YES NO WILL BE ANYTHING UNUSUAL OR -YES (Explainabove) NO NRC RESIDENT j NOT UNDERSTOOD?

STATE(s} V- DID ALL SYSTEMS FUNCTION AS REQUIRED?

Z YES [] NO (Explain above)

LOCAL VI OTHER GOV AGENCIES I- MODE OF OPERATION ESTIMATED ADDITIONAL INFO ON BACK MEDIA/PRESS RELEASE j ," UNTIL CORRECTED Op RESTARI DATE: ,.J/J WYES NO NRC FORM 361 (12,2000)