Dominion Energy Kewaunee, Inc.

N490 Hwy 42, Kewaunee, WI 54216-9511 APR I 8 2022 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 DOMINION ENERGY KEWAUNEE. INC.

KEWAUNEE POWER STATION P

Dominion jl Energy Serial No.22-116 LIC/WZ/R0 Docket No.: 50-305 License No.: DPR-43 2021 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Enclosed is the Kewaunee Power Station (KPS) 2021 Annual Radioactive Effluent Release Report for January through December 2021. This report is submitted to meet the requirements of KPS Technical Requirements Manual (TRM) Section 10.3. Also included is Revision 23 of the Radiological Environmental Monitoring Manual and Revision 0 of the Solid Radioactive Waste Process Control Program, submitted to meet the requirements of KPS TRM Section 10.1.1.

If you have questions or require additional information, please feel free to contact Mr.

William Zipp at 920-304-9729.

Sincerely,

~~~~(_~

Bradly J. McMahon Director Kewaunee Site Commitments made by this letter: NONE

1

e
e i.
e
e I *
  • 1* 1* I. * * * * * * * * * * * * * * *
e
e * * * * * * * *
  • a Dominion ta==' Energy Dominion Energy Kewaunee, Inc.

2021 Annual Radioactive Effluent Release Rep-ort Kcewarunee Power Station

I*

le i*

I * * * * * * * * * * * * * * * * *., * * * * * * * * * * * * * * * *,.

le I :.

i * *

Table of Contents Section Description 0.0 Summary............................................................................................................ 3 1.0 Introduction........................................................................................................ 4 1.1 Effluent Dose Limits.......................................................................................... 4 2.0 Gaseous Effluents.............................................................................................. 5 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents................................. 5 2.2 Gaseous Effluent Data....................................................................................... 6 Table 2.1 Gaseous Effluents - Summation of all Releases (Continuous Mode)7 Table 2.2 Dose from Gaseous Effluents............................................................ 8 3.0 Liquid Effluents............................................................................................... 10 3.1 Lower Limits of Detection (LLD) for Liquid Effluents.................................. 10 3.2 Liquid Batch Release Statistics....................................................................... 10 3.3 Liquid Effluent Data........................................................................................ 10 Table 3.1 Liquid Effluents - Summation of all Releases (Batch Mode)......... 11 Table 3.2 Dose from Liquid Effluents............................................................. 12 3.4 Ground Water Monitoring.............................................................................. 13 4.0 M.eteorological Data........................................................................................ 15

5. 0 Solid Waste Disposal....................................................................................... 15 Table 5.1 Solid Waste and Irradiated Fuel Shipments.................................... 16 6.0 Supplemental Information............................................................................... 19 Appendix A Solid Radioactive Waste Process Control Program (PCP) Revision 0 Appendix B Radiological Environmental Monitoring Manual (REMM) Revision 23 Page 2 of20
  • J

0.0

SUMMARY

On October 22, 2012, Dominion made known the decision to permanently shut down the Kewaunee Power Station (KPS). On February 25, 2013, Dominion Energy Kewaunee (DEK) submitted a certification of permanent cessation of power operations pursuant to 10 CPR 50.82(a)(l)(i), stating that DEK has decided to permanently cease power operation ofKPS on May 7, 2013. On May 15, 2013 the NRC docketed the certification for permanent removal of fuel from the reactor vessel pursuant to 10 CPR 50.82(a)(l)(ii). Therefore the 10 CPR Part 50 license no longer authorizes KPS to operate the reactor or emplace or retain fuel in the reactor vessel, as specified in 10 CFR 50.82(a)(2).

On June 15, 2017, the transfer of all spent fuel from the KPS Spent Fuel Pool (SFP) to the Independent Spent Fuel Storage Installation (ISFSI) was completed. All remaining irradiated materials were removed from the SFP in October 2017.

All radioactive liquid was drained from systems in the Auxiliary Building by the end of the first week of August 2018.

The remaining effluent release paths are continuous gaseous radioactive releases from the Auxiliary Building Vent and batch liquid radioactive waste releases to Lake Michigan. Batch gaseous radioactive releases and continuous liquid radioactive releases are no longer performed.

In 2021 there were no identified gaseous radionuclides released from the Auxiliary Building Vent, and no batch liquid radioactive waste releases to Lake Michigan.

In 2021 there were no solid and /or oil waste shipments off site.

Page 3 of20

1.0 INTRODUCTION

This report is being submitted in accordance with the requirements of Kewaunee Technical Requirements Manual, Section 10.3.2 and the Offsite Dose Calculation Manual, Section 15.2. It includes data from all effluent releases made from January 1 - December 31, 2021. The report contains summaries of the gaseous and liquid releases made to the environment including the quantity, characterization, time duration and calculated radiation dose at the site boundary resulting from these releases. The report also includes a summation of solid radioactive waste disposal and the revisions to the Solid Radioactive Waste Process Control Program (PCP) and Radiological Environmental Monitoring Manual (REMM). Values indicated as 0 (zero) in this report refer to actual values less than the detection limits. A table of these less than detectable (LLD) values is identified in sections 2.1 and 3.1.

1.1 Effluent Dose Limits Specifications are set to ensure that offsite doses are maintained as low as reasonably achievable while still allowing for practical and dependable evolutions at the Kewaunee Power Station.

The Kewaunee Offsite Dose Calculation Manual (ODCM) describes the methodology and parameters used.in:

1.

The calculation of radioactive liquid effluent monitoring instrumentation alarm/trip set points.

2.

The calculation of radioactive liquid and gaseous concentrations, dose rates and cumulative quarterly and annual doses. The ODCM methodology is acceptable for use in demonstrating compliance with 10 CFR 20.1301/1302; 10 CFR 50, Appendix I; and 40 CFR 190.

Page 4 of20

.\\ * * * * * * * * * * * * * *., * *

  • I*
  • 1 el.:

.1 * * * * * * * * * * * * * * * * * *

  • 1*

I * *

  • I. *
  • I.

!e *

  • ie :* * * * * * * * * * * *,.

2.0 GASEOUS EFFLUENTS 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents Gaseous radioactive effluents are released in the continuous mode. Batch gaseous radioactive releases are no longer performed. The Auxiliary Building ventilation stack was sampled continuously for Particulates, Gross Alpha, and Strontium 90, by an "off-line" sample train. This stack was also grab-sampled monthly for Tritium.

The LLD's for gaseous radio-analyses, as listed in Table 13.2.1-1 of the Kewaunee ODCM are:

Analysis Particulate Gamma Emitters Particulate Gross Alpha Strontium 90 Tritium (H-3)

LLD (µCi/ml) l.00E-11 l.00E-11 l.00E-11 l.00E-06 The nominal "a priori" LLD values are shown below.

Isotope a priori LLD (µCi/ml)

a. Particulate emissions:

Mn-54 Co-60 Cs-134 Cs-137 Ce-144 1.llE-13 3.57E-13 4.69E-13 l.68E-13 l.24E-12

b. Composite particulate samples:

Sr-90 Gross Alpha l.00E-14 l.00E-14 These "a priori" LLDs represent the capabilities of the counting systems in use, not an after the fact "a posteriori" limit for a particular measurement.

Page 5 of20

__J

2.2 Gaseous Effluent Data Table 2.1 presents a quarterly summation of the total activity released and average release rates of gaseous effluents ( continuous mode). Table 2.2 presents the dose limits for gaseous effluents, and the calculated doses this year from gaseous effluents.

Page 6 of20 e: * * * * * * * * * * * * * * * * * *

  • 1* :*
e,.

Table 2.1 Gaseous Effluents - Summation of all Releases (Continuous Mode) 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Total Particulates Total Activity Released (Ci)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Average Release Rate (µCi/sec)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Tritium Total Activity Released (Ci)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Average Release Rate (µCi/sec)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Gross Al:gha Released (Ci)

O.OOE+OO 0.00E+OO O.OOE+OO O.OOE+OO O.OOE+OO Page 7 of20

Table 2.2 Dose from Gaseous Effluents The offsite dose limits from radioactive materials in gaseous effluents are specified in Section 13.2.3 of the Kewaunee ODCM and can be summarized as follows:

Organ Quarterly Limit 7.5 mrem Annual Limit 15.0 mrem The following offsite doses were calculated using equation 2.2 from the Kewaunee ODCM. Calculated offsite doses versus quarterly and annual limits are shown below.

In 2021 there were no identified gaseous radionuclides released from the Auxiliary Building Vent.

1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Annual

1. Organ Dose Specification (mrem) 7.50E+00 7.50E+00 7.50E+00 7.50E+00 l.50E+0l Total Body Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Bone Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Liver Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Page 8 of20 e!*

  • 1
  • 1.,

.1 * * * * * * * * * * * * * * * * * * *

  • Table 2.2 ( continued)

Dose from Gaseous Effluents 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Annual Thyroid Actual Dose (mrem)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

% of Specification O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Kidney Actual Dose (mrem)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

% of Specification O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Lung Actual Dose (mrem)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

% of Specification O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO GI-LLI Actual Dose (mrem)

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

% of Specification O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

e * * * * * * * * * * *
  • Page 9 of20

3.0 LIQUID EFFLUENTS 3.1 Lower Limits of Detection (LLD) for Liquid Effluents Liquid radioactive effluents are released as batch releases. Continuous liquid radioactive releases are no longer performed. Each batch is sampled prior to release and analyzed for gamma emitters and tritium. A fraction of each sample is retained for a proportional composite which is then analyzed for Gross Alpha, Strontium 90, Iron 55 and Nickel 63.

The LLD's for liquid batch release radio-analyses, as listed in Table 13.1.1-1 of the Kewaunee ODCM are:

Analysis Principal Gamma Emitters Tritium (H-3)

Gross Alpha Strontium 90 Iron 55 Nickel 63 LLD (µCi/ml) 1.00 E-06 1.00 E-05 5.00 E-07 5.00 E-08 1.00 E-06 1.00 E-04 There were no batch liquid radioactive waste releases to Lake Michigan in 2021, therefore there are no "a priori" LLD values shown below.

3.2 Liquid Batch Release Statistics The following is a summation of all liquid batch releases during 2021.

Number of batch releases................................... O Total time for all batch releases (min)............... O Maximum time for a batch release (min)........... O Minimum time for a batch release (min)............ O Average time for a batch release (min)............... O 3.3 Liquid Effluent Data The following Table 3.1 presents a quarterly summation of the total activity released (batch mode) and average concentration for all liquid effluents. It also presents the gross alpha activity released, volume of waste released, and volume of dilution water used. Table 3.2 presents the doses from liquid effluents for each quarter and the calculated doses this year from liquid effluents.

Page 10 of 20 e!* * * * * * * *.,,. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

  • I * * * *
  • Table 3.1 Liquid Effluents - Summation of all Releases (Batch Mode)

I *

  • 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Total Fission and Activation Products Total Release (Ci) 0.00E+O0 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Average Concentration

(µCi/ml) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Tritium Total Release (Ci) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Average Concentration

(µCi/ml) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification Limit(3.0E-3 µCi/ml) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Gross Al12ha Activity Total Release (Ci) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Volume of Waste Released Total (liters) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Volume of Dilution Water 1*

Total (liters) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 le * * *

  • There were no batch liquid radioactive waste releases to Lake Michigan in 2021.

Page 11 of 20

Table 3.2 Dose from Liquid Effluents There were no batch liquid radioactive releases to Lake Michigan in 2021.

1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Annual Total Body Specification (mrem) l.50E+00 l.50E+00 l.50E+OO 1.50E+00 3.00E+O0 Actual Dose (mrem) 0.O0E+O0 0.00E+00 0.00E+00 O.O0E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.00E+0O 0.00E+00 Organs Specification (mrem) 5.00E+00 5.00E+00 5.00E+00 5.00E+00 l.00E+0l Bone Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 O.00E+00 0.0OE+O0 Liver Actual Dose (mrem) 0.00E+00 0.00E+O0 0.00E-+:00 O.O0E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 Thyroid Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0OE+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.O0E+00 Kidney Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 O.00E+00 0.00E+00 Lung Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GI-LLI Actual Dose (mrem) 0.00E+00 0.00E+00 0.00E+00 O.00E+00 0.00E+00

% of Specification 0.00E+00 0.00E+00 0.00E+00 0.O0E+00 O.00E+00 Page 12 of20

  • 1.I

3.4 Ground Water Monitoring The Kewaunee Power Station has 14 wells used to sample for groundwater contamination. Eight of the wells are located to monitor for leakage from the Auxiliary Building (AB). The other six wells are designated as Monitoring Wells (MW) and sample areas outside the industrial security area to identify any spread of contamination. As the data below indicates there was no gamma activity identified and the tritium in all the AB and MW wells was below Minimum Detectable Concentrations (MDC). The tritium levels have decreased to below MDC in the AB and MW wells since the plant was permanently shut down in 2013. There were no voluntary ground water communications, no spills, and no leaks in 2021.

Sample Point Tritium Total Gamma Activity Sample Date pCi/L

µ,Ci/ml AB-707 4/29/2021

<278 None Detected AB-708 4/29/2021

<278 None Detected AB-709 5/18/2021

<295 None Detected AB-710 5/17/2021

<295 None Detected AB-711 6/2/2021

<302 None Detected AB-712 6/3/2021

<302 None Detected Page 13 of 20

Sample Point Sample Date AB-715 7/15/2021 AB-717 7/15/2021 MW-701 8/19/2021 MW-702 8/19/2021 MW-703 9/9/2021 MW-704 9/9/2021 MW-705 10/6/2021 MW-706 10/6/2021 Tritium pCi/L

<317

<317

<384

<384

<273

<273

<339

<339 Page 14 of 20 Total Gamma Activity

µCi/ml None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected

!*

  • I.

I

  • 1* *,.

1*

I

  • 1*
  • 1* 1*
  • le I

I * * *.

4.0 METEOROLOGICAL DATA Meteorological data is no longer required to be reported in accordance with the Kewaunee ODCM Rev. 19, Section 15.2.

5.0 SOLID WASTE DISPOSAL Table 5.1 is a summation of solid and oil radioactive waste shipped during 2021. Presented are the types of waste streams, waste classification, and major nuclides.

In 2021 there were no solid and /or oil waste shipments off site.

Page 15 of 20

Table 5.1 Solid Waste and irradiated Fuel Shipments A. Solid Radioactive Waste Shipped Off-Site for Burial or Disposal

1.

Type of Waste with Estimate of Major Nuclide Composition Resins, Filters, and Volume Evaporator Bottoms Waste Class ft3 m3 A

0.00E+00 0.00E+00 B

0.O0E+00 0.00E+00 C

0.00E+00 0.0OE+00 Unclassified 0.00E+00 0.00E+O0 All 0.O0E+00 0.00E+O0 Major nuclides for the above table: NA Dry Active Waste Volume Waste Class ft3 m3 A

0.00E+00 0.00E+00 B

0.00E+00 0.OOE+O0 C

0.00E+00 0.00E+O0 Unclassified 0.00E+00 0.00E+O0 All 0.00E+00 0.00E+00 Major nuclides for the above table: NA Page 16 of20 Curies Shipped Curies 0.00E+00 0.00E+00 0.OOE+00 0.O0E+00 0.O0E+O0 Curies Shipped Curies 0.00E+O0 0.O0E+O0 0.00E+O0 0.00E+00 0.00E+00 e1

  • e:

e:.,.,

I ie

  • le I :e I.

I :.

1*

~. *,.

I,.

1*,.

Table 5.1 ( continued)

Solid Waste and Irradiated Fuel Shipments Irradiated Components Volume Waste Class ft3 m3 A

O.OOE+OO O.OOE+OO B

O.OOE+OO O.OOE+OO C

O.OOE+OO O.OOE+OO Unclassified O.OOE+OO O.OOE+OO All O.OOE+OO O.OOE+OO Major nuclides for the above table: NA Other Waste -Oil Volume Waste Class ft3 m3 A

O.OOE+OO O.OOE+OO B

O.OOE+OO O.OOE+OO C

O.OOE+OO O.OOE+OO Unclassified O.OOE+OO O.OOE+OO All O.OOE+OO O.OOE+OO Major nuclides for the above table: NA Sum of All Low-Level Volume Waste Waste Class ft3 m3 A

O.OOE+OO O.OOE+OO B

O.OOE+OO O.OOE+OO C

O.OOE+OO O.OOE+OO Unclassified O.OOE+OO O.OOE+OO All O.OOE+OO O.OOE+OO Major nuclides for the above table: NA Page 17 of 20 Curies Shipped Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies Shipped Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies Shipped Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

B.

Table 5.1 ( continued)

Solid Waste and Irradiated Fuel Shipments Irradiated Fuel Shipments Number of Shipments None Mode of Transportation NA Destination NA No irradiated fuel shipments were made from the Kewaunee Power Station during 2021.

Page 18 of 20

I,. I.,.

6.0 SUPPLEMENTAL INFORMATION 6.1 Abnormal Releases or Abnormal Discharges No abnormal releases or abnormal discharges were made from the Kewaunee Power Station during the report period.

6.2 Non-routine Planned Discharges No non-routine planned discharges were made from the Kewaunee Power Station during the reporting period.

6.3 Program Revisions In accordance with Technical Requirements Manual Section 10.1.1.c.3 and the Offsite Dose Calculation Manual Section 15.2.f, revisions to the Process Control Program, Offsite Dose Calculation Manual, or the Radiological Environmental Monitoring Program for the report period are listed below.

6.3.l Process Control Program Revision O of the Process Control Program was issued February 25, 2021. See Appendix A.

6.3.2 Offsite Dose Calculation Manual There were no revisions to the Offsite Dose Calculation Manual during the report period.

6.3.3 Radiological Environmental Monitoring Manual Revision 23 of the Kewaunee Power Station Radiological Enviromnental Monitoring Manual (REMM) was issued October 20, 2021. See Appendix B.

6.4 Major Changes to the Radioactive Liquid, Gaseous and Solid Waste Systems There were no changes to the radioactive liquid, gaseous, or solid waste systems during the reporting period.

6.5 Effluent Monitoring System Inoperability There were no effluent radiation monitors inoperable for the consecutive time period listed in the ODCM for this report period.

6.6 Corrections to Previous Reports None.

Page 19 of 20

6.7 Other None.

Page 20 of20 I* * * * * * * * * * *.

~ * * * * * * * * * * * * *

  • I *
  • I * *
  • le
  • 1* **

1*

  • I:

Appendix A Kewaunee Power Station Solid Radioactive Waste Process Control Program (PCP)

Revision 0 February 25, 2021

~*

This page intentionally left blank

.1 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

  • Kewaunee Power Station Cit!. Dominion ii P Energy Administrative Procedure

Title:

Solid Radioactive Waste Process Control Prgram (PCP)

Procedure Number RP-KW-114 Revision Summary Revision Number 0

Effective Date and Approvals On File This revision O procedure replaces the Word formatted procedure NAD-01.16 with this FrameMaker formatted procedure.

0 The content of the procedure was updated to reflect the current plant decommissioning SAFSTOR configuration.

INFORMATION USE

DOMINION TABLE OF CONTENTS Section RP-KW-114 Revision O Page 2 of 10 Page 1.0 PURPOSE..................................................................... 3 2.0 SCOPE....................................................................... 3 3.0 INSTRUCTIONS................................................................ 4 4.0 RECORDS..................................................................... 8 4.1 QA Records............................................................... 8 4.2 Non-QA Records........................................................... 8 5.0 ADMINISTRATIVE INFORMATION................................................. 8 5.1 Commitments.............................................................. 8 5.2 Responsibilities............................................................. 8 5.3 Definitions................................................................. 9 5.4 Reference................................................................. 9 INFORMATION USE

DOMINION RP-KW-114 Revision 0 Page 3 of 10 1.0 PURPOSE 1.1 This procedure provides instruction for describing the requirements and responsibilities for the Solid Radioactive Waste Process Control Program (PCP).

2.0 SCOPE 2.1 This procedure implements the requirements of 1 0CFR50.36(a), July 1967 Atomic Energy Commission (AEC) General Design Criteria 70, 1 0CFR61.56, and the Off-Site Dose Calculation Manual (ODCM).

2.2 This program applies to each radioactive waste stream employed on site which routinely requires preparation and packaging for off-site processing or disposal as solid radioactive waste including the following:

INFORMATION USIE

  • Spent resin media from the Liquid Radioactive Waste Processing System.
  • Filter media from the Liquid Radioactive Waste Processing System.This waste stream includes cotton mop heads used for plant area decontamination activities.

0 Dry Active Waste (DAW) consisting of plastic bags and sheeting, rags, wood, paper, scrap metal, and large components (e.g., steam generators), from activities conducted in the radiologically controlled areas of the plant.

DOMINION 3.0 INSTRUCTIONS RP-KW-114 Revision 0 Page 4 of 10 3.1 The Solid Radioactive Waste Process Control Program is implemented using the following procedures:

  • HP-09.015, High Integrity Containers Operating Guidelines
  • HP-09.017, 14-190H, 14-210H, and 14-215H Cask Shipping Procedure
  • HP-09.025, 8-1208 Cask Shipping Procedure for Shipping a Liner
  • HP-09.026, RAMSHP Operating Procedure
  • HP-09.027, FIL TRK Operating Procedure
  • HP-09.028, OSM Operating Procedure
  • HP-09.029, RADMAN Operating Procedure
  • HP-09.030, 8-120A Cask Shipping Procedure
  • RP-KW-009-003, Hydraulic Compactor Operation
  • RP-KW-009-005, Radioactive Waste Storage and Inventory
  • RP-KW-009-011, Waste Stream Analysis
  • RP-KW-009-014, Shipping Casks - Certificates/Procedures
  • RP-KW-009-024, Inspection of Low Level Radioactive Waste Packages in Storage
  • RP-KW-009-031, Radioactive Material Shipping
  • RP-KW-009-032, HIC/Liner Shipment Preparation
  • RP-KW-009-037, Energy Solutions Containerized Waste Facility Shipments 3.2 Radioactive waste shipments SHALL be sent in accordance with applicable NRC, DOT, State, Burial Site, and Processing Facilities regulations and requirements.

3.3 Radioactive waste SHALL be shipped ONLY to licensed burial sites or processing facilities in accordance with applicable NRC, DOT, and State regulations.

INFORMATION USE

i* *

1. ;. * * * * * * * * * * * * * * * *
  • DOMINION RP-KW-114 Revision 0 Page 5 of 10 3.4 A Radwaste Sampling and Analysis Program SHALL be implemented to ensure compliance with 1 0CFR61. Scaling factors will be developed to calculate concentrations of hard to measure isotopes from more easily determined isotopes. The scaling factors will enable concentrations of all 10CFR61 required isotopes to be determined for each radioactive waste shipment.

3.5 IF shipping for disposal, radioactive material content and waste class SHALL be determined based on a pre-established radionuclide distribution AND dose rate to curie content conversion in accordance with approved procedures.

3.6 Packaging of radioactive waste SHALL be in containers meeting NRC, DOT, Burial Site, and Processing Facilities requirements and regulations, EXCEPT under special exemption request approvals.

3. 7 Each radioactive waste package SHALL be assigned a unique identification number for traceability of records.

3.8 Container integrity SHALL be verified by visual or physical examination to assure an acceptable waste package for transportation and an acceptable waste form for disposal.

3.9 Wet radioactive wastes are processed through the use of High Integrity Containers (HIC) which meet the stability requirements of 1 0CFR61.56(b) for disposal.

3.1 O Wet radioactive waste processing SHALL be in accordance with the PCP to meet shipping, and processing and burial site requirements. Shipments NOT meeting the provisions of the PCP SHALL be suspended.

3.11 The dewatering process SHALL be conducted to provide a waste product with as little free standing water as possible, but in no case in excess of 1 percent by package volume.

3.12 WHEN shipping DAW:

0 During preparation and packaging, wastes SHALL be examined to ensure exclusion of unacceptable waste products such as water and oil

  • Absorbent materials may be utilized to absorb incidental liquids to ensure no free standing liquids are contained in the package.

INFORMATION USE

DOMINION RP-KW-114 Revision 0 Page 6 of 10 3.13 Quality Assurance INFORMATION USE 3.13.1 Radioactive waste procedures SHALL contain Quality Control Inspection Hold Points where applicable.

3.13.2 The appropriate QA controls required by 1 0CFR20, Appendix G, Section 111.3 are encompassed by the following:

  • DOM-QA-1, Nuclear Facility Quality Assurance Program Description
  • Routine documented QA audits of radioactive waste processing, packaging, and shipping activities
  • Management evaluations of QA audits
  • Management review and approval of procedures for waste classification and waste characteristics
  • Management review and approval of procedures for all other radioactive waste related activities 3.13.3 QA requirements of 10CFR71, Subpart H, apply only to a package containing a Type B quantity of radioactive material. These requirements are satisfied by maintaining documents appropriate to each package used to ship a Type B quantity:
  • Controlled copy of the owner's handling procedure 0 NRC user registration
  • Package safety analysis report
  • Package design analysis
  • Package design drawings
  • Package acceptance test results
  • Package maintenance program

le le le

  • L*

DOMINION RP-KW-114 Revision 0 Page 7 of 10 3.14 Use of Contractor for Waste Processing INFORMATION USE 3.14.1 Contractor supplied process or service may be used for the processing of radioactive waste for off-site disposal. For the operation of such a process, it may be.desirable to use process control measures and procedures developed by the contractor specifically for the system or process. Therefore, previously addressed process control measures for a particular type waste may be superseded by contractor supplied measures as appropriate.

3.14.2 Prior to use of a contractor supplied process or service for waste processing, a management review of the contractor's process control and procedures shall be performed to assure an operation compatible with plant operation and in accordance with regulatory requirements.

3.14.3 For contractor processing of waste that is intended to be shipped for disposal at a licensed radioactive waste burial site, additional precautions are to be taken to assure a final waste product that meets the appropriate waste stability requirements of 1 0CFR61.56. In particular, the following items, as applicable, are to be documented prior to utilization for waste processing:

a. A general description of the solidification or dewatering process, including type solidification agent (if applicable), major process equipment and interface with plant equipment, types of waste that can be processed, and operating parameters.
b. Process control measures that provide for the verification of the generation of a suitable waste product, including items (as may be appropriate for the process method) such as representative sampling, laboratory tests, and acceptance criteria, etc.
c. Specifically approved procedures for the operation of the process equipment that will assure operation within the bounds as delineated by the process control measures.
d. Appropriate acceptance criteria for evaluating the acceptability of the final waste product.

DOMINION 4.0 RECORDS RP-KW-114 Revision O Page 8 of 10 The following QA records and non-QA records are generated by or created according to this document and are listed on the KPS Records Retention Schedule. These records shall be maintained according to the KPS Records Management Program.

4.1 QA Records

  • None 4.2 Non-QA Records
  • None 5.0 ADMINISTRATIVE INFORMATION 5.1 Commitments
  • None 5.2 Responsibilities 5.2.1 Radiological Protection and Chemistry Manager (RPCM)

The RPCM is responsible for:

  • Administration of the Solid Radioactive Waste Process Control Program 0 Assigning trained and qualified personnel to implement the program
  • Ensuring any revisions to the program receive the appropriate reviews and approvals including the Facility Safety Review Group (FSRG)

[DSAR 4.1.2.1.2]

5.2.2 Nuclear Oversight Nuclear Oversight is responsible for:

  • Periodic inspection and review of all types of radioactive waste shipments to ensure procedural compliance INFORMATION USE

DOMINION RP-KW-114 Revision O Page 9 of 10 5.3 Definitions 5.3.1 Free Standing Liquid Drainable liquid or free liquid able to be removed from a waste package through a solidification, absorption, or dewatering process. It includes liquid which is still visible after solidification or dewatering is complete or is drainable from the low point of a punctured container.

5.3.2 High Integrity Container (HIC)

A waste container used as an alternative to solidifying some waste streams, especially ion exchange resins and filter media/sludges.

Provides the long term stability required to meet the structural stability requirements of 1 0CFR61. Is designed to maintain its structural integrity for 300 years while being subjected to corrosive chemicals, thermal cycling, radiation dose, ultra-violet radiation, transportation, handling, and disposal site trench compaction.

5.3.3 Off-Site Disposal Off-Site Disposal includes licensed burial or processing facilities. The processing activities are designed to minimize the volume of radwaste ultimately sent to the burial facility.

5.3.4 Radioactive Waste Any material designated as waste which also contains detectable radioactive material resulting from the operation of the plant.

5.4 Reference INFORMATION USE 5.4.1 Other

a. KPS Defueled Safety Analysis Report (DSAR)
b. Technical Requirements Manual {TRM)
c.

Off-site Dose Calculation Manual (ODCM)

d. July 1967 Atomic Energy Commission (AEC) General Design Criteria 70
e.

DOM-QA-1, Nuclear Facility Quality Assurance Program Description

f. USNRC Waste Form Technical Position, Revision 1, (Letter K-91-011 ), dated 1/24/91

DOMINION INFORMATION USE RP-KW-114 Revision 0 Page 10 of 10

g. NUREG-0800, Rev. 2, July 1981, USNRC Standard Review Plan, Section 11.4, Solid Waste Management Systems
h. USNRC Branch Technical Position - ETSB 11-3, Design Guidance for Solid Radioactive Waste Management Systems Installed in Light-Water-Cooled Nuclear Power Reactor Plants, Rev. 2, July 1981
i.

USN RC Generic Letter 84-12 (K-84-95), Compliance with 1 0CFR Part 61 and Implementation of the Radiological Effluent Technical Specifications (RETS) and Attendant Process Control Program (PCP), dated 4/30/84

j. 1 0CFR20.2006, Transfer for Disposal and Manifests and 10CFR20, Appendix G, Requirements for Transfers of Low-Level Radioactive Waste Intended for Disposal at Licensed Land Disposal Facilities and Manifests
k.

10CFR50.36(a), Technical specifications on effluents from nuclear power reactors I.

1 0CFR61, Licensing Requirements for Land Disposal of Radioactive Waste

m.

NUREG-0133, October 1978, Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants

n.

NUREG-0472, Revision 3, 9/3/82, Standard Radiological Effluent Technical Specifications for Pressurized Water Reactors

o.

1 0CFR71, Packaging and Transportation of Radioactive Material

p.

Letter NRC-84-178, Hintz to Varga, Radiological Effluent Technical Specifications - TAC #08145

q. 49CFR173, Shippers General Requirements for Shipments and Packagings; Subpart I, Radioactive Materials
r.

Barnwell Waste Management Facility Site Disposal Criteria, Chem-Nuclear Systems, Inc., Document S20-AD-010

s.

USNRC License No. 12-13536-01, Barnwell Facility Special Nuclear Material License

t.

South Carolina Department of Health and Environmental Control License No. 097, Barnwell Facility Operating License

u. NRG Generic Letter 96-07, Interim Guidance on Transportation of Steam Generator, USNRC, December 5, 1996 I

Appendix B Kewaunee Power Station Radiological Environmental Monitoring Manual (REMM)

Revision 23 October 20, 2021

This page intentionally left blank e!.I * * * * * *.,

(,,...

[.

l,..

  • t.

\\. * * * *

  • Dominion Energy Kewaunee, Inco Kewaunee Power Station RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL (REMM)

Approved By:

Approved By:

Revision 23 DATE:

October 20, 2021 DJ Shannon/

Date:

Date:

Reviewed By:

TP Olson/

,z-1-INY Date:

/tJ/.2,:,/;,;,;i./


J,,~=..e=----______c~".L_

I Facility Sat up Reviewed By:

BJ McMahon/ ~

\\_ ~ c.~

Director-Kewa~ Site Date:

10 J ~0 / ~o ~t 7

KEWAUNEE POWER STATION REMM Revision 23 October 20, 2021 RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL Table of Contents 1.0 Introduction................................................................................................................... 1-1 1.1 Purpose................................................................................................................ 1-1 1.2 Scope............................................................................................. _...................... 1-1 1.3 hnplementation......................................................................................"............. 1-2 2.0 REMP Requirements...................... _.............................................................................. 2-1 2.1 ODCM 13.5 Requirements................................................................................. 2-1 2.2 REMJVI Requirements......................................................................................... 2-2 REMJVI 2.2.1/2.3.1 Monitoring Program............................................................ 2-3 REMM 2.2.2/2.3.2 Land Use Census................................................................. 2-7 REMJVI 2.2.3/2.3.3 Interlaboratory Comparison Program................................ 2-10 REMM 2.4.1 Reporting Requirements............................................................. 2-11 3.0 UMP ][mplementation................................................................................................ 3-1 3.1 Sampling Requirements...................................................................................... 3-1 3.2 Analysis Methodolo"gy........................................................................................ 3-1 3.3 Detection capability (LLD) Requirements.......................................................... 3-1 3.4 Contracted Vendor (CV) Reporting Requirements............................................. 3-2 3.5 Quality Assurance Program................................................................................ 3-3 3.6 Sample Descriptions........................................................................................... 3-4 Table 2.2.1-A Table 2.2.l-B Table 2.2.1-C Table 2.2.1-D Table 2.3.1-A Figure 1 Figure 2 TaMes & Figures Radiological Environmental Monitoring Program Type and Frequency of Collection Sampling Locations, Kewaunee Power Station Reporting Levels for Radioactivity Concentrations in Environmental Samples Detection Capabilities for Environmental Sample Analysis Lower Limit of Detection (LLD)

Environmental Sampling Location Ground Monitoring Wells ei

1.

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL 1.0 Introduction 1.1 Purpose REMM Revision 23 October 20, 2021 The purpose of this document is to defme the Radiological Environmental Monitoring Program (REMP) for the Kewaunee Power Station (KPS). The REMP is required by the Offsite Dose Calculation Manual (ODCM) 13.5.

This document is known as the Radiological Environmental Monitoring Manual (REMM) and is intended to serve as a tool for program administration and as a guidance document for contractors which implement the monitoring program.

1.2 Scope This program defmes the sampling and analysis schedule which was developed to provide representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from plant decommissioning activities. This monitoring program implementsSection IV.B.2 of Appendix I to I 0CFR Part 5 0 and thereby verifies that the measurable concentrations of radioactivity and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Guidance for the development of this monitoring program is provided by the Radiological Assessment Branch Technical Position on Environmental Monitoring. This program has been developed in accordance with NUREG 0472.

On October 22, 2012, Dominion made known the decision to permanently shut down the Kewaunee Power Station (KPS). On February 25, 2013, Dominion Energy Kewaunee (DEK) submitted a certification of permanent cessation of power operations pursuant to IO CFR 50.82( a)(l )(i), stating that DEK has decided to permanently cease power operation ofKPS on May 7, 2013. On May 15, 2013 the NRC docketed the certification for permanent removal of fuel from the reactor vessel pursuant to 10 CFR 50.82(a)(l)(ii). Therefore, the IO CFRPart 50 license no longer authorizes KPS to operate the reactor or emplace or retain fuel in the reactor vessel, as specified in IO CFR 50.82(a)(2). On June 151\\ 2017 transfer of all spent nuclear fuel into dry cask storage was completed.

On April 24, 2017 Radiation Safety and Control Services, Inc. (RSCS) submitted Technical Support Document No.16-086 Rev. 2, Kewaunee Shut-Down Environmental Radionuclides of Concern and Radiological Environmental Monitoring Manual Changes, to KPS. This document evaluated the radionuclides of concern for environmental releases after permanent shutdown ofKPS. The result of the evaluation was the optimization of the environmental program due to radioactive decay and reduced source terms during the decommissioning phase of the plant.

The program will provide field and analytical data on the air, aquatic, and terrestrial radioecology of the area near the Kewaunee Power Station so as to:

I. Determine the effects of the decommissioning activities on the environment.

2. Serve as a gauge of the operating effectiveness of in-plant control of waste discharges; and
3. Provide data on the radiation dose to the public by direct or indirect pathways of exposure.

1-1

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL 1.3 Implementation REMM Revision 23 October 20, 2021 This document is considered, by reference, to be part of the Off site Dose Calculation Manual. This is as required by KPS Technical Requirements Manual (TRM) 10.1.1. The REMM is controlled as a separate document for ease of revision, use in the field and use by contractors. This format was approved by the NRC as part of TS Amendment No. 64, which provided Radiological Effluent Technical Specifications (RETS) for KPS.

The REMP is set up to be implemented by a vendor and controlled by KPS in accordance with procedure RP-KW-113, "Radiological Effluent and Environmental Monitoring Programs". Monthly reviews of the vendor's progress report are performed by KPS in accordance with this manual in section 3.4. Annual reviews and submittals of the vendor's report and monitoring data are checked and approved by KPS in accordance with procedure RP-KW-HSP-HPE-280, "Annual Effluent and Environmental Report Review and Submittal." All sample collection, preparation, and analysis are performed by the vendor except where noted. Procedure RP-KW-HSP-HPE-164, "Environmental Sample Collection," outlines the environmental sample collection performed by KPS.

Periodic reviews of monitoring data and an annual land use census will be used to develop modifications to the existing monitoring program. Upon approval, these modifications will be

  • incorporated into this document per RP-KW-280, Revision and Control of ODCM and REMM,"so that it will accurately reflect the current radiological environmental monitoring program in effect for KPS.

The remainder of this document is divided into two sections.

The first section,

2. 0 REMP Requirements, describes the different TRM and REMM requirements associated with the REMP. The second section, 3.0 REMP Implementation, describes the specific requirements used to implement the REMP.

1-2

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL 2.0 REMP Requirements REMM Revision 23 October 20, 2021 KPS TS Amendment No. 104 implemented the guidance provided in Generic Letter 89-01, "Implementation of Programmatic Controls for Radiological Effluent Technical Specifications (RETS)." These changes included:

1. Incorporation of programmatic controls in the Administrative Controls section of the TS to satisfy existing regulatory requirements for RETS, and
2. Relocation of the procedural details on radioactive effluents monitoring, radiological environmental monitoring, reporting details, and other related specifications from the TS to the ODCM.

Relocating the procedural details to the ODCM allows for revising these requirements using the 10CFR50.59 process instead ofrequiring prior NRC approval using the TS Amendment process.

The RETS requirements were incorporated verbatim into the ODCM, Revision 6. Several of these requirements pertain only to the environmental monitoring program and therefore have been relocated into this document (REMM, Revision 3 and 4) and are identified as REMM requirements.

All KPS TS related REMM requirements were removed from KPS TS and placed in the Technical Requirements Manual as part ofTRM Revision O on 4/26/2016.

2.1 ODCM 13.5 Requirements ODCM 13.5 provides the programmatic control, which requires a program to monitor for radiation and radionuclides in the environs of the plant. This is the reason for the existence of the REMP.

ODCM 13.5 also provides the programmatic control which requires:

a.

The program to perform the monitoring, sampling, analysis, and reporting in accordance with the methodology and parameters in the ODCM,

b.

A land use census to be performed, and

c.

Participation in an Interlaboratory Comparison Program.

The details of each requirement are described in the REMM requirements stated below.

TRM 10.3.1 requires an "Annual Radiological Environmental Operating Report," be submitted to the NRC each year. The specific contents of this report are detailed in REMM 2.4.1. Additional specific reporting requirements are listed in the other REMM requirements.

2-1

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL 2.2 REMM Requirements REMM Revision 23 October 20, 2021 The following REMM requirements include the procedural details that were originally located in the KPS RETS section and then relocated into Revision 6 of the ODCM, as discussed above. These requirements are specific to the radiological environmental monitoring program and have been relocated into this document for ease of use and completeness.

The REMM requirements for the Monitoring Program, Land Use Census, and the Interlaboratory Comparison Program include a detailed operating requirement (numbered 2.2.1, 2.2.2, and 2.2.3 respectively) and an associated verification requirement (numbered 2.3.l, 2.3.2, and 2.3.3 respectively), along with the basis for the requirement. Reporting requirements are listed in requirement REMM 2.4.1.

ODCM 13.0, USE AND APPLICATION, apply to both the ODCM and REMM.

2-2

ie I * * * *

  • I. :* * * * * * * * * * * * * * * * * * * * * *

~*

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM REMM Revision 23 October 20, 2021 REMM 2.2.1 The radiological environmental monitoring program shall be conducted as specified in Table 2.2.1-A.

APPLICABILITY:

At all times.

ACTIONS NON-CONFORMANCE CONTINGENCY MEASURES RESTORATION TIME A.

Radiological A.1 Prepare and submit to the In accordance with Environmental Monitoring NRC in the Annual the Annual Program not conducted as Radiological Environmental Radiological specified in REMM Table Operating Report, a Environmental 2.2.1-A.

description of the reasons Operating Report for not conducting the frequency.

program as required and the plans for preventing a recurrence.

B. Level of radioactivity in an B.1 -

--NOTES environmental sampling

1. Only applicable if the medium at a specified radioactivity/radionuclides location exceeds the are the result of plant reporting levels of REMM effluents.

Table 2.2.1-D when

2. For radionuclides other than averaged over any those in REMM calendar quarter.

Table 2.2.1-D, this report shall indicate the OR methodology and parameters used to estimate the potential annual dose to a MEMBER OF THE PUBLIC.

2-3

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL ACTIONS (continued)

NON-CONFORMANCE More than one of the radionuclides in REMM Table 2.2.1-D are detected in the environmental sampling medium and Concentration 1

+

Reporting level 1 Concentration 2 +.. -~ 1.0.

Reporting level 2 OR Radionuclides other than those in REMM Table 2.2.1-D are detected in an environmental sampling medium at a specified location which are the result of plant effluents and the potential annual dose to a MEMBER OF THE PUBLIC from all radionuclides is ~ the calendar year limits of DNC 13.1.2, DNC 13.2.2, DNC 13.2.3 CONTINGENCY MEASURES OR Prepare and submit to the

NRC, a Special
Report, pursuant to DNC 15.3, that (1)

Identifies the cause(s) for exceeding the limit(s) and (2)

Defines the corrective actions to be taken to reduce radioactive effluents so that the potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year limits of DNC 13.1.2, DNC 13.2.2, DNC 13.2.3 B.2 ---NOTES---

1. Only applicable if the radioactivity/radionuclides are not the result of plant effluents.
2. For radionuclides other than those in REMM Table 2.2.1-D, this report shall indicate the methodology and parameters used to estimate the potential annual dose to a MEMBER OF THE PUBLIC.

Report and describe the condition in the Annual Radiological Environmental Operating Report.

2-4 REMM Revision 23 October 20, 2021 RESTORATION TIME 30 days In accordance with the Annual Radiological Environmental Operating Report frequencv.

I !e I :e !.

I * *

  • I. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
  • KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL ACTIONS (continued)

NON-CONFORMANCE C.

Broad leaf vegetation samples unavailable from one or more of the sample locations required by REMM Table 2.2.1-A.

VERIFICATION REQUIREMENTS CONTINGENCY MEASURES C.1 Identify specific alternative locations for obtaining replacement samples and add them to the Radiological Environmental Operating Program.

C.2 When changes in sampling locations are permanent, then the sampling schedule in the REMM will be updated to reflect the new routine and alternative sampling locations. This revision will be submitted in the next Annual Radiological Environmental Operating Report.

VERIFICATION REMM 2.3.1 Collect and analyze radiological environmental monitoring samples pursuant to the requirements of REMM Table 2.2.1-A and the detection capabilities required by Table 2.2.1-A.

2-5 REMM Revision 23 October 20, 2021 RESTORATION TIME 30 days FREQUENCY In accordance with REMM Table 2.2.1-A

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL BASES REMM Revision 23 October 20, 2021 The radiological environmental monitoring program provides representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potentiai radiation exposures of MEMBERS OF THE PUBLIC resulting from the station decommissioning activities.

This monitoring program implementsSection IV.B.2 of Appendix I to 1 0CFR Part 50 and thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Guidance for this monitoring program is provided by the Radiological Assessment Branch Technical Position on Environmental Monitoring. Program changes may be initiated based on operational experience.

The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs ). The LLDs required by Table 2.3.1-A are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized that the LLD is defined as a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.

Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L.A., "Limits for Qualitative Detection and Quantitative Determination -Application to Radiochemistry," Anal. Chem. 40, 586-93 (1968), and Hartwell, J.K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).

2-6

  • * * * * * * * *
  • i. * * * * * * * * *.

J KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL REMM Revision 23 October 20, 2021 RADIOLOGICAL ENVIRONMENTAL MONITORING LAND USE CENSUS REMM 2.2.2 APPLICABILITY:

ACTIONS A land use census shall:

a.

Be conducted,

b.

Identify within a distance of 8 km (5 miles) the location, in each of the 10 meteorological sectors, of the nearest residence, and the nearest garden > 50 m2 (500 ft2) producing broad leaf vegetation. Sampling of broad leaf vegetation may be performed at the site boundary in each of two different direction sectors with the highest predicted D/Qs in lieu of the garden census. Requirements for broad leaf vegetation sampling 1n REMM Table 2.2.1-A item 4b shall be followed, including analysis of control samples.

At all times.

NON-CONFORMANCE CONTINGENCY MEASURES RESTORATION TIME A.

Land use census identifies location(s) that yields a calculated dose, dose commitment greater than the values currently being calculated in ODCM 13.2.3.1.

A.1 Identify the new location(s) in the next Radiological Environmental Operating Program.

2-7 In accordance with the Radiological Environmental Operating Report.

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL NON-CONFORMANCE

8. Land use census identifies location(s) that yields a calculated dose, or dose commitment (via the same exposure pathway) greater than 20% at a location from which samples are currently being obtained in accordance with REMM 2.2.1.

VERIFICATION REQUIREMENTS CONTINGENCY MEASURES 8.1 Add the new location(s) to the Radiological Environmental Operating Program.

8.2 Delete the sampling locations(s), excluding the control station location, having the lowest calculated dose, dose commitment(s) or D/Q value, via the same exposure pathway, from the Radiological Environmental Operating Program.

8.3 Submit in the next Radiological Environmental Operating Report documentation for a change which includes revised figures(s) and table(s) reflecting the new location(s) with information supporting the change in samplinQ locations.

VERIFICATION REMM 2.3.2 Conduct the land use census during the growing season using that information that will provide the best results, such as by a door-to-door survey, aerial survey, or by consulting local agricultural authorities.

Report the results of the land use census in the Annual Radiological Environmental Operating.

2-8 REMM Revision 23 October 20, 2021 RESTORATION TIME 30 days In accordance with Radiological Environmental Operating Report.

FREQUENCY 12 months

!e * * * * * * * * * * * * * * * *

  • KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL BASES REMM Revision 23 October 20, 2021 This requirement is provided to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the radiological environmental monitoring program are made if required by the door-to-door survey, from aerial survey or from consulting with local agricultural authorities. This census satisfies the requirements of Section IV.B.3 of Appendix I to 1 0CFR Part 50. Restricting the census to gardens of greater than 50 m2 provides assurance that significant exposure pathways via broad leaf vegetation will be identified and monitored since a garden of this size is the minimum required to produce the quantity (26 kg/yr) of broad leaf vegetation assumed in Regulatory Guide 1.109 for consumption by a child. To determine this minimum garden size, the following assumptions were made:
1.

20% of the garden was used for growing broad leaf vegetation (e.g., similar to lettuce and cabbage), and

2.

A broad leaf vegetation yield of 2 kg/m2.

2-9

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL REMM Revision 23 October 20, 2021 RADIOLOGICAL ENVIRONMENTAL MONITORING INTERLABORA TORY COMPARISON PROGRAM REMM 2.2.3 Analyses shall be performed on all radioactive materials, supplied as part of an lnterlaboratory Comparison Program that has been approved by the Commission.

APPLICABILITY:

At all times.

ACTIONS NON-CONFORMANCE CONTINGENCY MEASURES A.

Analyses not performed as required.

A.1 Report the corrective actions taken to prevent a recurrence to the NRG in the Annual Radiological Environmental Operating Report.

VERIFICATION REQUIREMENTS REMM2.3.3 BASES VERIFICATION Report a summary of the results obtained as part of the lnterlaboratory Comparison Program in the Annual Radiological Environmental Operating Report.

RESTORATION TIME In accordance with the Annual Radiological Environmental Operating Report.

FREQUENCY In accordance with the Annual Radiological Environmental Operating Report.

The requirement for participation in an approved lnterlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are valid for the purposes of Section IV.B.2 of Appendix I to 1 0CFR Part 50.

2-10

1* * * * * * :. * * * * * * * * * * * * * * * * *

Discussion

a.

Summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period, including a comparison with pre-operational studies, with operational controls as appropriate, and with previous environmental surveillance reports, and an assessment of the observed impacts of the plant decommissioning activities on the environment. The reports shall also include the results of land use censuses required by REMM 2.2.2.

b.

The results of analyses of radiological environmental samples and of environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures in the Radiological Environmental Monitoring Manual (REMM), as well as summarized and tabulated results of these analyses and measurements in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted as soon as possible in a supplementary report when applicable.

c.

A summary description of the radiological environmental monitoring program; legible maps covering all sampling locations keyed to a table giving distances and directions from the centerline of one reactor; the results-of licensee participation in the Interlaboratory Comparison Program, required by REMM 2.2.3; discussion of all deviations from the sampling schedule of Table 2.2.1-A; and discussion of all analyses in which the LLD required by Table 2.3.1-A was not achievable.

KPS TRM 10.3.1 provides the programmatic control, which requires that an Annual Radiological Environmental Operating Report be submitted to the NRC. It also states that this report shall include summaries, interpretations, and analysis of trends of the results of the REMP for the reporting period.

The procedural details of this report are included in this requirement. REMM 2.2.1/2.3.1, 2.2.2/2.3.2, and 2.2.3/2.3.3 also include specific reporting requirements. These requirements reference this REMM, along with TRM 10.3.1, as the method for reporting deviations from the current program during the reporting period, and require that this information be included in the Annual Radiological Environmental Operating Report.

2-11

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL

3. 0 REMP Implementation REMM Revision 23 October 20, 2021 The Radiological Environmental Monitoring Program for KPS is under the direction of a Contracted Vendor (CV). This section describes this program, as required by REMM 2.2.1 and the process the CV uses to perform it.

3.1 Sampling Requirements Table 2.2.1-A identifies the various samples required by the REMP. Identified in the "available sample locations" column in Table 2.2.1-A are the sample locations selected, in conjunction with the vendor, to meet or exceed the REMP requirements. Table 2.2.1-B includes the same requirements as in Table 2.2.1-A, but presents the information in a different format by identifying the type of samples required at each location and the collection frequency. Table 2.2.1-C identifies the location and description of each sample location. Figure 1 shows the physical location of each sample point on an area map.

3.2 Analysis Methodology Analytical procedures and counting methods employed by the CV will follow those recommended by the U.S. Public Health Service publication, Radioassay Procedures for Environmental Samples, January 1967; and the U.S. Atomic Energy Commission Health and Safety Laboratory, HASL Procedures Manual (HASL-300), 1972.

The manual is also available on-line at www.eml.st.dhs.gov/publications/procman.

Updated copies shall be kept on file at KPS or can be obtained from the CV with sufficient notification.

3.3 Detection Capability (LLD) Requirements The required detection capabilities for environmental sample and analysis are tabulated in terms of lower limits of detection (LLDs) in Table 2.3.1-A. The LLDs required by Table 2.3.1--A are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized that the LLD is defined as a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.

Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L.A., "Limits for Qualitative Detection and Quantitative Determination-Application to Radiochemistry," Anal. Chem. 40, 586-93 (1968), and Hartwell, J.K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).

3-1 e: * * * *

  • KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL 3.4 Contracted Vendor Reporting Requirements Monthly Progress Reports REMM Revision 23 October 20, 2021 Monthly progress reports will include a tabulation of completed analytical data on samples obtained during the previous 30 day period. Included in the report are the status of field collections and graphic representations indicating possible trends. One *copy of the reports will be submitted within 30 to 60 days of the reporting month. Monthly progress reports are reviewed for:

Reasonableness Consistency Accuracy Completeness Recognition of deficiencies Examination of any past deficiencies and corrective actions taken Recommendations for any modifications or improvements to the REMM Notify the vendor of any unusual or abnormal data noted during the review, including an evaluation of the applicability of REMM Specification 2.2.1.b.

The review shall include determination of the need to make notifications to State and Local Agencies due to levels of radioactive materials in water samples.

Annual Reports Annual reports will be submitted in two parts. Part I, to be submitted to the NRC, will be prepared in accordance with NRC Regulatory Guide 4.8. It will contain an introductory statement, a summary of results, description of the program, discussion of the results, and summary table. Part II of the annual report will include tables of analytical data for all samples collected during the reporting period, together with graphic presentation where trends are evident and statistical evaluation of the results. Gamma scan data will be complemented by figures ofrepresentative spectra ifrequested by KPS.

Non-Routine Reports If analyses of any samples collected show abnormally high levels of radioactivity, KPS will be notified by telephone immediately after data becomes available.

Action Limits The CV will report any radioactive concentrations found in the environmental samples which exceed the reporting levels shown in Table 2.2.1-D, CV to KPS column. These levels are set below the NRC required reporting levels (KPS to NRC column) so actions can be initiated to prevent exceeding the NRC concentration limits.

3-2

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL

3. 5 Quality Assurance Program REMM Revision 23 October 20, 2021 To ensure the validity of the data, the CV maintains a Quality Assurance (QA) Program, which employs quality control checks, with documentation of the analytical phase of its environmental monitoring studies. The program and procedures are defined in the CV's Quality Manual. The program shall be reviewed and meet the requirements of Regulatory Guide 4.15 and 1 0CFR21. All data related to quality control will be available for review by Dominion Energy Kewaunee upon reasonable prior notification. Proprietary information will be identified so that it may be treated accordingly.

Updated copies of the Quality Manual shall be kept on file at KPS or can be obtained from the CV with sufficient notification.

3-3

1*

i*,. * * * * * * * * * * * * * * * * * * * *

  • KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL
3. 6 Sample Descriptions A description of each of the samples required by this program follows:

Ambient Radiation REMM Revision 23 October 20, 2021 Two packets of thermo-luminescent dosimeters (CaSO4: Dy cards) are placed at fifteen locations as follows:

Four at the ISFSI fence as part of inner ring locations (K-lm, K-lo, K-lq, K-lr)

Four inner ring locations (K-lf, K-25, K-27, K-30)

Six outer ring locations (K-3, K-5, K-8, K-17, K-39, K-43)

One control location (K-2)

One packet is changed quarterly and one annually. Annual TLDs will serve as an emergency set to be read when needed. They will be exchanged annually (without reading) if not read during the year. To insure the precision of the measurement, each packet will contain two cards with four dosimeters each (four sensitive areas each for a total of eight). For protection against moisture each set of cards is sealed in a plastic bag and placed in a plastic container.

Each card is individually calibrated for self-irradiation and light response. Fading is guaranteed by the TLD vendor not to exceed 20% in one year. Minimum sensitivity for the multi-area dosimeter is 0.5 mR defined as 3 times the standard deviation of the background. Maximum Error (1 standard deviation) - 6°Co Gamma +/-0.2 mR or +/-3 %, whichever is greater. The maximum spread between areas on the same dosimeter is 3.5% at 1 standard deviation.

Reporting units for TLDs are mR/91 days for quarterly TLDs and mR/exposure period for annual TLDs.

Tests for uniformity and reproducibility of TLDs as specified in NRC Regulatory Guide 4.13 are performed annually.

Airborne Particulates Airborne particulates are collected at four locations (K-lf, K-2(control), K-8, and K-43) on a continuous basis on a 4 7 mm diameter filter at a volumetric rate of approximately one cubic foot per minute ( CFM). The filters are changed weekly, placed in protective envelopes, and delivered to the CV for Gamma Isotopic Analysis. Filter samples are analyzed weekly for gross beta activity after sufficient time (usually 3 to 5 days) has elapsed to allow decay of Radon and Thoron daughters. If gross beta concentrations in air particulate samples are greater than ten ( I 0) times the yearly mean of the control samples, gamma isotopic analysis shall be performed on the individual samples. Quarterly composites from each location receive Gamma Isotopic Analysis using a Germanium detector. All identifiable gamma-emitters are quantified. Reporting units are pCi/m3

  • 3-4

KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL Surface Water REMM Revision 23 October 20, 2021 Surface water is sampled quarterly from Lake Michigan at the KPS discharge (K-ld).

Samples are collected quarterly at the Green Bay Municipal Pumping station between Kewaunee and Green Bay (K-9) - both raw and treated water is collected.

Quarterly samples are also taken, when available, from creek locations (K-1 b, K-1 e) that pass through the reactor site. The samples are taken at a point near the mouth of each creek and at the shore of the drainage pond. The water is analyzed for gross beta activity in:

a.

The total residue,

b.

The dissolved solids, and

c.

The suspended solids.

The samples are also analyzed for K-40, Gamma Isotopic Analysis, tritium, and Sr-90. Reporting units are pCi/1.

Well Water One gallon of drinking water samples are taken once every three months from one off-site well, (K-13) and three on-site wells (K-lh, K-1 t, and K-1 u). All samples are analyzed for gross beta in the total residue, K-40, tritium, and by Gamma Isotopic Analysis. Samples from one on-site well are analyzed for Sr-90. Samples from K-lh, K-lt, and K-1 u are also analyzed for gross alpha. Reporting units are pCi/1.

Shoreline Sediment Shoreline sediment samples are taken semi-annually from three locations (K-lc, K-lj, K-9) in areas with potential for recreational value. Samples are analyzed for gross beta, Sr-90 and Gamma Isotopic Analysis. Reporting units are pCi/g dry weight.

Fish Fish are collected once per year (third quarter) near the discharge area (K-1 d). An alternate source for fish is a local fish market (e.g., LaFond's in Kewaunee). Flesh is separated from the bones and analyzed for gross beta activity and by Gamma Isotopic Analysis. The bones are analyzed for gross beta activity and Sr-90. Reporting units are pCi/g wet weight.

Vegetation Annually, during the 3rd quarter, samples of broad leaf vegetation grown and marketed for human consumption are collected from K-26 (control), depending upon the availability of samples. If samples are not available from this location, samples may be obtained from any local source so there is some sample of record. The location will be documented. In addition, two samples of broad leaf vegetation from the highest predicted X/Q and D/Q, if available, are collected annually from the farmland owned by Dominion Energy Kewaunee (K-23 a and b) and rented to a private individual for growing crops. Reporting units are pCi/g wet weight.

3-5

  • 1 ** *
  • e:
  • 1 e:* * * * * * *., * * * * * * * * * *
  • KEWAUNEE POWER STATION RADIOLOGICAL ENVIRONMENTAL MONITORING MANUAL REMM Revision 23 October 20, 2021 Twice during the growing season samples of the top two inches of soil are collected from five locations (K-lf, K-3(control), K-34, K-35 (control), K-38). The soil is analyzed for gross alpha and gross beta activities, for Sr-90, and Gamma Isotopic Analysis to identify and quantify gamma-emitting manmade radionuclides. Reporting units are pCi/g dry weight.

Cattle feed Once per year, during the first quarter when grass is not available, cattle feed (such as hay or silage) is collected from the five dairy farms (K-3 (control), K-34, K-35 (control), K-38, K-45). The analyses performed are the same as for grass. Reporting units are pCi/g wet weight.

Grass Grass is collected three times per year (2nd, 3rd, and 4th quarters) from the six dairy farms (K-3( control), K-5, K-35 ( control), K-34, K-38, and K-39) and from two on-site locations (K-1 band K-lf). The samples are analyzed for gross beta activity, for Sr-90, and Gamma Isotopic Analysis to identify and quantify gamma-emitting radionuclides. Reporting units are pCi/g wet weight.

Groundwater Monitoring Wells The Groundwater Protection Program (RP-KW-502, Groundwater Protection Program) consists of 14 wells. Figure 2 shows the locations of the 14 installed groundwater monitoring wells. The wells and locations are identified with a diamond shape in Figure 2. The wells are labeled MW (Monitoring Well) and AB (Auxiliary Building).

Results of analyses and a description of any event above Reporting Levels will be included in the Annual Radioactive Effluent Release Report for the 14 wells.

Any results exceeding the limits of Table 2.2.1-D shall be reported in accordance with section 2.2.1-B of the REMM, as well as:

D Informal notification to the State and Local Agencies before the end of the next business day.

D Providing a copy of the written 30 day NRC report to State and Local Agencies.

3-6

Exposure Pathway And/Or Sample

1.

Ambient Radiationc

2.

Airborne Particulates

3.

Waterborne

a.

Surfaceg

b.

Well

c.

Shoreline Sediment Table 2.2.1-A Radiological Environmental Monitoring Program Minimum Available Sample Required Samples a Locations h 8 Inner Ring locations K-lf, K-lm, K-lo, K-lq, K-lr, K-25, K-27,K-30, 6 Outer Ring locations K-3, K-5, K-8, K-17, K-39,K-43 1 Control location K-2 1 Population center K-43 1 Special interest location K-8 1 Nearby resident K-27 3 samples close to the site K-lf, K-8, K-43 boundary in highest averageX/Q 1 sample from the closest K-43 community having the highestX/Q 1 sample from a control K-2d location 1 Upstream sample K-lb,K-ld 1 Downstream sample K-le, K-9J 1-2 locations likely to be K-lh, K-lth, K-luh affected d K-13 1 off-site location 1 sample from K-lc,K-lj,K-9 downstream area with potential for recreational value Page 1 of 3

Sampling, Collection and Analysis Type of Analysis Frequency See Table 2.2.1-B Gamma dose See Table 2.2.1.B Continuous sampler operation Particulates Particulates; See Table 2.2.1-B gross beta analysis0 Gamma See Table 2.2.1-B isotopicf of composite (by location)

Grab sample Gross Beta, See Table 2.2.1-B Gamma isotopicf K-40 tritium, and Sr-90; Grab sample Gamma isotopicr, See Table 2.2.1-B tritium and K-40 analysis Gross Beta, One onsite well for Sr-90 3 onsite wells for gross alpha Grab sample Gamma isotopic f See Table 2.2.1-B analysis Gross Beta, Sr-90 REMM Rev.23 October 20, 2021

4.

5.

Exposure Pathway And/Or Sample Ingestion a.

Fish

b.

Food Products Miscellaneous samples not identified in NUREG-04 72k

a.

Soil

b.

Cattle feed C

  • Grass Table 2.2.1-A Radiological Environmental Monitoring Program Minimum Available Sample Required Samples
  • Locations b 1 random sample of K-ld commercially and recreationally important species in the vicinity of the plant.

Two samples of broad K-23a, K-23b leaf vegetation grown nearest each of two different offsite locations within 5 miles of the plant since milk sampling is no longer performed.k 1 sample 15-30 km distant since milk K-26 (control) sampling is no longer performed.

None required K-lf, K-34, K-35 (control)

K-38 K-3 (control)

None required K-35 ( control)

K-34, K-38, K-45 K-3 ( control)

None required K-lb, K-lf, K-35 (control), K-39 K-5, K-34, K-38 K-3 ( control)

Page 2 of 3

Sampling, Collection and Analysis Type of Analysis Frequency See Table 2.2.1-B Gamma Isotopicf and Gross Beta on edible portions, Gross Beta and Sr-90 on bones See Table 2.2.1-B Gamma Isotopicf Analysis.

Gross Alpha/Beta See Table 2.2.1-B Sr-90 Gamma Isotopicf Gross Beta See Table 2.2.1-B Sr-90 Gamma Isotopicr Gross Beta See Table 2.2.1-B Sr-90 Gamma Isotopicf REMM Rev.23 October 20, 2021

a.
b.

C.

d.
e.
f.
g.
h.
1.
j.
k.

Table Notations for Table 2.2.1-A The samples listed in this column describe the minimum sampling required to meet REMP requirements.

Additional details of sample locations are provided in Table 2.2.1-C and Figure 1. The REMP requires that samples be taken from each of the "available sample locations" listed (see section 3.1). Deviations from the required sampling schedule will occur if specimens are unobtainable due to hazardous conditions, seasonal unavailability, malfunction of automatic sampling equipment and other legitimate reasons. If specimens are unobtainable due to sampling equipment malfunction, reasonable efforts shall be made to complete corrective actions prior to the end of the next sampling period.

All deviations from the sampling schedule shall be documented, as required by REMM 2.4.1.c, in the Annual Radiological Environmental Operating Report. It is recognized that, at times, it may not be possible or practicable to continue to obtain samples of the media of choice at the most desired location or time. In these instances suitable alternative media and locations may be chosen for the particular pathway in question and appropriate substitutions made within 30 days in the REMM. The cause of the unavailability of samples for that pathway and the new location(s) for obtaining replacement samples will be identified in the Annual Radiological Environmental Operating Report.

For the purposes of this table, each location will have 2 packets ofthermoluminescent dosimeters (TLDs). The TLDs are CaSO4: Dy cards with 2 cards/packet and 4 dosimeters/card (four sensitive areas each for a total of eight dosimeters/packet). The NRC guidance of 40 stations is not an absolute number. The number of direct radiation monitoring stations has been reduced according to geographical limitations; e.g., Lake Michigan. The frequency of analysis or readout for TLD systems depends upon the characteristics of the specific system used and selection is made to obtain optimum dose information with minimal fading.

The purpose of this sample is to obtain background information. If it is not practical to establish control locations in accordance with the distance and wind direction criteria, other sites that provide valid background data may be substituted.

Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.

Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.

The "upstream sample" shall be taken at a distance beyond significant influence of the discharge. The "downstream" sample shall be taken in an area near the mixing zone.

Well water samples shall be taken when this source is tapped for drinking or irrigation purposes in areas where the hydraulic gradient or recharge properties are suitable for contamination.

In the event elevated analyses are reported by CV for gamma isotopic or tritium, a review will be conducted with the option to retest additional analysis for hard to detect isotopes or alpha emitters. The additional test may include Fe-55, Ni-63, or alpha emitters anticipated on current plant conditions.

Two samples to be collected, Raw and Treated See Regulatory Guide 4.1, Revision 2. Broad leaf vegetation, as well as grass, soil, and cattle feed, are a sufficient substitute if milk samples are not performed.

Page 3 of 3 REMM Rev.23 October 20, 2021

I !* *

  • 1: * * * * * * * * * * * * * * * * * * *,. * * * * * * * * * * * * * * * * *
  • Location Weekly Monthly K-lb K-lc K-ld K-le K-lf APg K-lh K-lj K-lm K-lo K-lq K-lr K-lt K-lu K-2 APg K-3 K-5 K-8 APg K-9 K-13 K-17 K-23a K-23b K-25 K-26 K-27 K-30 K-34 K-35 K-38 K-39 K-43 APg K-45 Table 2.2.1-B Type and Frequency of Collection Quarterly Semi-Annually SW GRa ssb SW SW GRa TLD so WW SSb TLD TLD TLD TLD WW WW TLD GRa TLD so GRa TLD TLD swr ssb WW TLD TLD TLD TLD GR*

so GR*

so GR*

so GRa TLD TLD Page 1 of 2 Annually FI0 CFd BLV0 BLV0 BLV0 CFd CFd CFd CFd REMM Rev.23 October 20, 2021

___J

a.
b.

C.

d.
e.
f.
g.

Code AP CF FI BLV Table Notations for Table 2.2.1-B Three times a year, second (April, May, June), third (July, August, September), and fourth (October, November, December) quarters To be collected in May and November Annually in third quarter (July, August, or September)

First (January, February, March) quarter only Alternate since milk sampling is no longer performed Two samples, raw and treated The frequency may be increased dependent on the dust loading.

Descril!tion Code Descril!tion Code Airborne Particulate GR Grass SW Cattle feed so Soil WW Fish ss Shoreline Sediment Broad Leaf Vegetation TLD Thermo-luminescent Dosimeter Page 2 of 2 Descril!tion Surface Water Well Water REMM Rev.23 October 20, 2021 i* * * * * * * * * * *

  • * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
  • I.

ie I :* i. * * * * * * * *

  • Code K-1 K-lb K-lc K-ld K-le K-lf K-lh K-lj K-lm K-lo K-lq K-lr K-lt K-lu K-2 K-3r K-5 Typea I

I I

I I

I I

I I

I I

I I

C I/C I

Table 2.2.1-C Sampling Locations, Kewaunee Power Station Distance (Miles t Location and Sector Onsite - generic code Middle Creek 0.12N 87°32'8.62"W 44°20'44.80"N 0.10N 500' North of Condenser Discharge 87°32'4.21"W 44°20'39.76"N 0.lOE Condenser Discharge 87°32'1.87"W 44°20'32.?l"N South Creek 0.12 S 87°32'5.03"W 44°20'25.04"N 0.12 S Maintenance Waste Oil and Material Storage Building 87°32'14"W 44°21'26N North Well 0.12NW 87°32'18.05"W 44°20'39.15N 0.10 S 500' south of Condenser Discharge 87°3 l '58.75"W 44°20'29.33"N ISFSI East 0.15N 87°32'8.78"W 44°20'37.BN ISFSINorth 0.16N 87°32'9.19"W 44°20'40.llN ISFSI West 0.16N 87°32'13.4l"W 44°20'39.86N ISFSI West 0.13 N 87°32'14.25"W 44°20'39.09N Gatehouse 0.10 ESE 87°32'4.47"W 44 °20'30. 79N 0.05 SSW Maintenance Building 87°33'21"W 44°21' 19N 8.91 NNE WPS Operations Building in Kewaunee 87°29'59.62"W 44°28'25.49N 5.9N Lyle and John Siegmund Farm, N2815 Hwy 42, Kewaunee 87°32'35.98"W 44°25'39.21N 3.2NNW Ed Paplham Farm, E4160 Old Settlers Rd, Kewaunee 87°33 '47.l0"W 44°23'2.83"N Page 1 of 3 REMM Rev.23 October 20, 2021

Code Typea K-8 I

K-9 C

K-13 C

K-17 I

K-23a I

K-23b I

K-25 I

K-26° C

K-27 I

K-30 I

K-34 I

K-35d C

K-38 I

K-39 I

K-43° I

Table 2.2.1-C Sampling Locations, Kewaunee Power Station Distance (Milest Location and Sector Saint Isadore the Fanner Church, 18424 Tisch Mills Rd, 4.85WSW Tisch Mills 87°37'50.85"W 44°19' 18.48"N Green Bay Municipal Pumping Station, six miles east of 11.5NNE Green Bay (sample source is Lake Michigan from Rostok Intake 2 miles north of Kewaunee) 87°46'16.94"W 44°29'16.55" 3.0 SSW Rand's General Store, Two Creeks 87°33'48.23"W 44°18'8.69N 4.0W Klimesh's Farm, N885 Cty Tk B, Kewaunee 87°36'47.52"W 44°21 '21.62N 0.5W 0.5 miles west of plant, Kewaunee site 87°32'3.38"W 44°21 '12.12N 0.6N 0.6 miles north of plant, Kewaunee site 87°32'43.93"W 44°20'32.36N 1.9 SW Wotachek Fann, B3968 Cty Tk BB, Two Rivers 87°34' 10.67"W 44°19'38.8lN 9.1 SSW Wilfert's Vegetable Stand 7528 Manitou Dr., Two Rivers 87°39'3.75"W 44°11 '21.60N 1.53 NW Schleis Fann, B4298 Sandy Bay Rd 87°33 '6.93"W 44°21 '22.96"N 0.8N End of site boundary 87°32'2.61"W 44 °2 l' 12.86"N 2.7N Leon & Vicky Struck Fann, Nl549 Lakeshore Dr, Kewaunee 87°3 l '14.33"W 44°22'48.13N 6.71 WNW Duane Ducat Fann, N1215 Sleepy Hollow, Kewaunee 87°40'1.53"W 44°22' 10.90N 2.45WNW Dave Sinkula Fann, N890 Town Hall Road, Kewaunee 87°34'56.92"W 44°21 '22.64"N 3.46N Francis Wotja Fann, N1859 Lakeshore Road, Kewaunee 87°31 '14.28"W 44°23'28.25"N 2.71 SSW Gary Maigatter Property, 17333 Highway 42, Two Rivers 87°33 '42.99"W 44°18'26.63"N Page 2 of 3 REMM Rev. 23 October 20, 2021

  • * * * * * * * * * * * * * * * * * * * * * *
  • I.

ie :* * * * * * * * * * * * * * * * *

  • Table 2.2.1-C Sampling Locations, Kewaunee Power Station Code Typea Distance (Milest Location and Sector K-45 I

5.lN Wakker's Dairy, N2348 Highway 42, Kewaunee 87°32 '29. 76"W 44°24'32.S"N Table Notations for Table 2.2.1-C

a. I = indicator; C = control.
b. Distances are measured from reactor stack.
c. Location K-18 was changed because Schmidt's Food Stand went out of business. It was replaced by Bertler's Fruit Stand (K-26). It was replaced with Sandy's Vegetable in 2007.

The location as of 2009 is Wilfert's Vegetable Stand.

d. Removed from the program in fall of 2001, back to program in August 2008.
e. K-7 moved to a nearby location and relabeled K-43, within 0.2 miles of original, August/September 2010.
f.

Location K-3 is an indicator for ambient radiation and a control for soil, cattle feed, and grass.

Page 3 of 3 REMM Rev.23 October 20, 2021

Table 2.2.1-D Reporting Levels for Radioactivity Concentrations in Environmental Samples Medium Radionuclide Reporting Levels CVtoKPSa KPStoNRCb Airborne Particulate (pCi/m3)

Gross Beta 1

Cs-134 1

10 Cs-137 1

20 Water (pCi/1)

Gross Alpha 10 Gross Beta

. 30 H-3 10,000 20,oooc Mn-54 100 1,000 Co-60 30 300 Cs-134 10 30 Cs-137 20 50 Sr-90 gd Grass, Cattle Feed, and Broad Leaf Gross Beta 30 Vegetation (pCi/g wet)

Cs-134 0.2 1

Cs-137 0.2 2

Sr-90 1

Soii Shoreline Sediments (pCi/g)

Gross Beta 50 Cs-134 5

Cs-137 5

Sr-90 5

Fish (pCi/g wet)

Gross Beta (Flesh, Bones) 10

a.
b.

C.

d.

Mn-54 30.0 Co-60 10.0 Cs-134 (Flesh) 1 1.0 Cs-137 (Flesh) 2 2.0 Sr-90 (Bones) 2 Radionuclides will be monitored by the CV and concentrations above the listed limits will be reported to KPS.

Concentrations above the listed limits will be reported to NRC as required by REMM 2.2.1.b.

For drinking water samples, this is 40CFR Part 141 value. Ifno drinking water pathway exists, then a value of 30,000 pCi/1 may be used.

The Sr-90 values are based on the EPA drinking water standards. See note "e" of Table 2.3.1-A for further information Page 1 of 1 REMM Rev. 23 October 20, 2021

    • * * * * * * * * * * * * * * * * * * * * * * *.i.; * * * * * * * * * * * * * * * * * *
  • * * * * * * * * * * * * * * * * * * * * * * :. i.

I :e Analysis Gross Beta H-3 Mn-54 Co-60 Cs-134 Cs-137 Sr-90e Table 2.3.1-A Detection Capabilities for Environmental Sample Analysisa Lower Limit of Detection (LLD) b,c Water Airborne Fish Food Products Particulate (pCi/kg, wet)

(pCi/1)

(pCi/m3)

(pCi/kg, wet) 4 0.01 2000d 15 130 15 130 15 0.05 130 60 18 0.06 150 80 5

Sediment (pCi/kg, dry) 150 180 REMM Rev.23 Page 1 of 3 October 20, 2021

Table Notations/or Table 2.3.1-A

a. This list does not mean that only these nuclides are to be considered. Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environment Operating Report.
b. Required detection capabilities for thermoluminescent dosimeters used for environmental measurements are given in Regulatory Guide 4.13.
c. The LLD is defined, for purposes of these requirements, as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.

For a particular measurement system, which may include radiochemical separation:

4.66sb LLD=----------------=-

E X

V X

2.22 x

Y x

e-AAt Where:

LLD is the a priori lower limit of detection as defined above, as picocuries per unit mass or

volume, Sb is the standard deviation of the background counting rate or of the counting rate of blank sample as appropriate, as counts per minute, E is the counting efficiency, as counts per disintegration, V is the sample size in units of mass or volume, 2.22 is the number of disintegrations per minute per picocurie, Y is the :fractional radiochemical yield, when applicable,
11. is the radioactive decay constant for the particular radionuclide, and

~t for environmental samples is the elapsed time between sample collection, or end of the sample collection period, and time of counting, Typical values ofE, V, Y, and ~t should be used in calculation.

Page 2 of 3 REMM Rev. 23 October 20, 2021 e! * * * * * * *

e
  • i.

L d.

e.

Table Notations/or Table 2.3.1-A (con 't)

It should be recognized that the LLD is defined as a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori ( after the fact) limit for a particular measurement. Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions. Occasionally background fluctuations, unavoidable small sample sizes, the presence of interfering nuclides, or other uncontrollable circumstances may render these LLDs unachievable. In such cases, the contributing factors shall be identified and described in the Annual Radiological Environmental Operating Report.

lfno drinking water pathway exists, a value of 3,000 pCi/1 may be used.

This is NOT a NUREG-0472 required value. It is based on EPA drinking water standards, which tie into the NEI Groundwater Protection Initiative that was implemented at KPS on August 4, 2006.

Page 3 of 3 REMM Rev.23 October 20, 2021

J

. I L

. I

lt,&LI.
f,:,11**.U FIGURE1 FIGL'-.?.E 1 ENVIRON.YENTAL $AMf'Lit;r; L()l'.:IITION' A

t:-'3 INTAKE::¢:i l<tlPP/EN\\ISL;DGN l"cge 1 01' 1


'REMM Page 1 of 1 Rev.23 October 20, 2021 el.! *.

~

1* :.

1* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

~

FIGURE2 FIGURE 2