Committed to Nuclear Excelle Kewaunee Nuclear Power Plant Operated by Nuclear Management Company, LLC NRC-03-044 10 CFR 50.36a(a)(2)
April 29, 2003 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 KEWAUNEE NUCLEAR POWER PLANT DOCKET 50-305 LICENSE No. DPR-43 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2002 Enclosed please find a copy of the Kewaunee Nuclear Power Plant Radioactive Effluent Release Report for January through December 2002. This report is submitted to meet the requirements of Technical Specification 6.9.b.2.
/
Thomas Coutu tZAf CA_,e_
Thomas Coutu Site Vice-President, Kewaunee Plant DFS cc US NRC Senior Resident Inspector US NRC Region IlIl Enclosure 1:rets N490 Highway 42
- Kewaunee, Wisconsin 54216-9510 Telephone: 920.388.2560
RADIOACTIVE EFFLUENT RELEASE REPORT m .. .m ,-I f .Me dim X0 IiII II 9-g.... , .
NUCLEAR MANAGEMENT COMPANY, LLC I
Committed to Nuclear Excellence I
L L
DOCKET 50-305 L
L I-KEWAUNEE NUCLEAR POWER PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1 - December 31, 2002 Wisconsin Public Service Corporation Green Bay, Wisconsin April 16, 2003
Table of Contents Section Description 0.0 Summary ............ 3 1.0 Introduction .......... 3 1.1 Effluent Dose ............ 3 2.0 Gaseous Effluents ............ 4 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents .................................. 4 2.2 Gaseous Batch Release Statistics .............................................. 6 2.3 Gaseous Effluent Data .............................................. 6 Table 2.1 Gaseous Effluents - Summation of all Releases ............................... 7 Table 2.2 Gaseous Effluents - Elevated Releases ............................................. 8 Table 2.3A Gaseous Release Total ............................................... 0 Table 2.3B Gaseous Release Continuous .............................................. 18 Table 2.3C Gaseous Release Batch ............................................. 26 Table 2.4 Dose From Gaseous Effluents .............................................. 34 3.0 Liquid Effluents ............................................. 36 3.1 Lower Limits of Detection (LLD) for Liquid Effluents ................................... 36 3.2 Liquid Batch Release Statistics ............................................. 38 3.3 Liquid Effluent Data ............................................. 38 Table 3.1 Liquid Effluents - Summation of all Releases ................................ 39 Table 3.2A Liquid Effluents - Batch Releases 1st Quarter .............................. 40 Table 3.2B Liquid Effluents - Batch Releases 2nd Quarter ............................. 42 Table 3.2C Liquid Effluents - Batch Releases 3rd Quarter ............................. 44 Table 3.2D Liquid Effluents - Batch Releases 4th Quarter ............................. 46 Table 3.3A Liquid Effluents - Continuous Releases 1st Quarter .................... 48 Table 3.3B Liquid Effluents - Continuous Releases 2nd Quarter ................... 50 Table 3.3C Liquid Effluents - Continuous Releases 3rd Quarter .................... 52 Table 3.3D Liquid Effluents - Continuous Releases 4th Quarter .................... 54 Table 3.4 Dose From Liquid Effluents ............................................. 56 4.0 Unplanned Releases ............................................. 58 5.0 Meteorological Data .............................................. 58 6.0 Solid Waste Disposal .............................................. 58 Table 6.1 Solid Waste and Irradiated Fuel Shipments ..................................... 59 7.0 Program Revisions .............................................. 61 8.0 Reportable Occurrences .............................................. 61 Appendix A Meteorological Data Page 2 of 61
0.0
SUMMARY
During 2002 all solid, liquid, and gaseous radioactive effluents from the Kewaunee Nuclear Plant were well below regulatory limits. For individual effluent streams, the quarterly limit most closely approached was:
GASEOUS: Ingestion Pathway-Organ Liver Quarterly Limit (mRems) 7.5 Actual Dose (mRems) 0.00002016 (2nd Quarter)
% of Specification 0.0002689 LIQUID: Ingestion Pathway-Organ GI-LLI Quarterly Limit (mRems) 5 Actual Dose (mRems) 0.008593 (1s'Quarter)
% of Limit 0.17 SOLID: No upper limit for solid radioactive waste applies.
Cubic Meters Shipped 18.4 m3 (650 fl3)
1.0 INTRODUCTION
This report is being submitted in accordance with the requirements of Kewaunee Technical Specifications, Section 6.9.b.2 and the Offsite Dose Calculation Manual, Section 3/4.7. It includes data from all effluent releases made from January 1 - December 31, 2002. The report contains summaries of the gaseous and liquid releases made to the environment including the quantity, characterization, time duration and calculated radiation dose at the site boundary resulting from these releases. The report also includes a summation of solid waste disposal, revisions to the Process Control Program and the Offsite Dose Calculation Manual, and addresses the cumulative meteorological data.
1.1 Effluent Dose Limits Specifications are set to insure that offsite doses are maintained as low as reasonably achievable while still allowing for practical and dependable operation of the Kewaunee Plant.
The Kewaunee Offsite Dose Calculation Manual (ODCM) describes the methodology and parameters used in:
1.) The calculation of radioactive liquid and gaseous effluent monitoring instrumentation alarm/trip setpoints.
2.) The calculation of radioactive liquid and gaseous concentrations, dose rates and cumulative quarterly and annual doses. The ODCM methodology is acceptable for use in demonstrating compliance with 10 CFR 20.106; 10 CFR 50, Appendix l; and 40 CFR 190.
Page 3 of 61
2.0 GASEOUS EFFLUENTS 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents Gaseous radioactive effluents are released in both the continuous mode and the batch mode. The auxiliary building stack is sampled continuously for particulates, halogens and Strontium by an "off-line" sample train. This stack is also grab-sampled daily for gaseous gamma emitters. Batch releases are sampled prior to release for principal gaseous and particulate gamma emitters, halogens and tritium.
The LLD's for gaseous radioanalyses, as listed in Table 4.4 of the Kewaunee ODCM are:
Analysis LLD (ipCi/ml)
Gaseous Gamma Emitters 1.00 E-04 Iodine 131 3.00 E-12 Particulate Gamma Emitters 1.00 E-l 1 Particulate Gross Alpha 1.00 E-l 1 Strontium 89, 90 1.00 E-l l Noble Gases, Gross Beta or Gamma 1.00 E-06 The nominal "a priori" LLD values are shown below.
Isotope a priori LLD (pICi/ml)
- a. Gaseous emissions:
Kr-87 5.61E-08 Kr-88 1.02E-07 Xe-133 6.68E-08 Xe-133m 2.75E-07 Xe-135 2.99E-08 Xe-138 1.13E-07 Page 4 of 61
- b. Particulate emissions:
Mn-54 1.11 E-13 Fe-59 2.27E-13 Co-58 2.28E-13 Co-60 3.57E-13 Zn-65 1.68E-13 Mo-99 2.73E-13 Cs-134 4.69E- 13 Cs-137 1.68E-13 Ce-141 2.08E-13 Ce-144 1.24E-12
- c. Other identifiable gamma emitters:
Ar-41 3.97E-10 Kr-85 8.63E-05 Kr-85m 4.62E-08 Kr-89 2.04E-06 Xe-127 4.20E-08 Xe-131m 1.82E-06 Xe-135m 1.90E-08 Xe-137 2.88E-07 1-131 1.32E-13
- d. Composite particulate samples:
Sr-89 1 E-14 Sr-90 1 E-14 Gross Alpha 1.00 E-14 These "a priori" LLDs represent the capabilities of the counting systems in use, not an after the fact "a posteriori" limit for a particular measurement.
Page 5 of 61
2.2 Gaseous Batch Release Statistics The following is a summation of all gaseous batch releases made during 2002.
Number of batch releases ........................... 34 Total time for all batch releases (min)............ 11264.0 Maximum time for a batch release (min)............. 1219.0 Average time for a batch release (min)............. 331.3 Minimum time for a batch release (min)............. 8.0 2.3 Gaseous Effluent Data and average The following table 2.1 presents a quarterly summation of the total activity released quarterly sums of individual release rates of four categories of gaseous effluents. Table 2.2 lists the the same data, gaseous radionuclides released by continuous and batch modes. Table 2.3 is essentially gaseous effluents, and but is presented as monthly summations. Table 2.4 presents the dose limits for the calculated doses this year from gaseous effluents.
Page 6 of 61
Table 2.1 Annual Radioactive Effluent Release Report 2002 Gaseous Effluents - Summation of all Releases Fission and Activation Gases 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Total Activity Released (Ci) 3.163E-003 6.076E-003 1.494E-002 4.15 1E-003 Average Release Rate (pCi/sec) 4.023E-004 7.7271E-004 1.900E-003 5.279E-004 lodines Total Activity Released (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Average Release Rate (piCi/sec) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Particulates Total Activity Released (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Average Release Rate (giCi/sec) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Gross Alpha Released (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Tritium Total Activity Released (Ci) 6.721E-001 9.545E-001 7.376E-001 4.751E-004 Average Release Rate (jtCi/sec) 8.548E-002 1.214E-001 9.382E-002 6.042E-005 Page 7 of 61
Table 2.2 Annual Radioactive Effluent Release Report 2002 Gaseous Effluents Nuclides Released (Ci)
Continuous Mode 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Fission Gases Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Iodines Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Particulates Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 8 of 61
Table 2.2(cont)
Annual Radioactive Effluent Release Report 2002 Gaseous Effluents Nuclides Released (Ci)
Batch Mode Fission Gases Ar-41 2.262E-005 O.OOOE+000 1.643E-003 6.988E-004 Kr-85m O.OOOE+000 O.OOOE+000 3.663E-004 4.389E-005 Kr-87 O.OOOE+000 O.OOOE+000 1.722E-005 Kr-88 O.OOOE+000 O.OOOE+000 3.408E-004 5.83 1E-005 Xe-133m 0.OOOE+000 1.009E-004 O.OOOE+000 O.OOOE+000 Xe-133 3.103E-003 5.901E-003 8.908E-003 3.01 1E-003 Xe-135 3.775E-005 7.374E-005 3.683E-003 3.217E-004 Total 3.163E-003 6.076E-003 1.494E-002 4.15 1E-003 Iodines Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Particulates Total O.OOOE+000 0.OOOE+000 0.OOOE3+000 O.OOOE+000 Page 9 of 61
Table 2.3A Annual Radioactive Effluent Release Report 2002 1st Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope January February March Total Ar-41 2.262E-005 O.OOOE+000 O.OOOE+000 2.262E-005 Xe-133 8.740E-005 0.OOOE+000 3.016E-003 3.103E-003 Xe-135 3.775E-005 O.OOOE+000 0.OOOE+000 3.775E-005 Total 1.478E-004 O.OOOE+000 3.016E-003 3.163E-003 Particulates (Curies)
Isotope January February March Total Total 0.OOOE+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope January February March Total Total O.OOOE+000 0.OOOE+000 0.OOOE+000 O.OOOE+000 Page lOof61
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2002 1st Quarter Gaseous Release Total of all Releases Summary January February March Total Total Noble Gases (Ci) 1.478E-004 0.OOOE+000 3.0166E-003 3.163E-003 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 1.530E-005 3.655E-001 3.066E-001 6.721E-001 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 11 of 61
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2002 2nd Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope April May June Total Xe-133m O.OOOE+000 1.009E-004 O.OOOE+000 1.009E-004 Xe-133 3.338E-004 5.469E-003 9.804E-005 5.901E-003 Xe-135 O.OOOE+000 7.374E-005 0.OOOE+000 7.374E-005 Total 3.338E-004 5.644E-003 9.804E-005 6.076E-003 Particulates (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 12 of 61
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2002 2nd Quarter Gaseous Release Total of all Releases Summary April May June Total Total Noble Gases (Ci) 3.338E-004 5.644E-003 9.804E-005 6.076E-003 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 6.828E-001 2.717E-001 3.949E-005 9.545E-001 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 13 of 61
Table 2.3A (con't)
Annual Radioactive Effluent Release Report 2002 3rd Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope July August September Total Ar-41 O.OOOE+000 1.643E-003 O.OOOE+000 1.643E-003 Kr-85m O.OOOE+000 3.663E-004 O.OOOE+000 3.663E-004 Kr-88 O.OOOE+000 3.408E-004 O.OOOE+000 3.408E-004 Xe-133 O.OOOE+000 6.213E-003 2.695E-003 8.908E-003 Xe-135 O.OOOE+000 3.674E-003 8.863E-006 3.683E-003 Total O.OOOE+000 1.224E-002 2.704E-003 1.494E-002 Particulates (Curies)
Isotope July August September Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope July August September Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 14of61
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2002 3rd Quarter Gaseous Release Total of all Releases Summary July August September To eta]
Total Noble L Gases (Ci) O.OOOE+000 1.224E-002 2.704E-003 1.494E-002 Total Halogens I~ (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Uf. Total Particulate Gross Beta-Gamma L Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) O.OOOE+000 2.999E-OOI 4.377E-001 7.376E-001 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 L.
Page 15 of 61
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2002 4th Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope October November December Total Ar-41 6.9888E-004 0.OOOE+000 0.OOOE+000 6.988E-004 Kr-85m 4.389E-005 0.OOOE+000 0.OOOE+000 4.389E-005 Kr-87 1.722E-005 0.OOOE3+000 0.OOOE3+O00 1.722E-005 Kr-88 5.8311E-005 0.OOOE+000 O.OOOE3+000 5.831E-005 Xe-133 2.376E-003 6.348E-004 0.OOOE3+000 3.01 IE-003 Xe-135 3.2177E-004 0.OOOE+000 0.OOOE+000 3.217E-004 Total 3.516E-003 6.3481E-004 0.OOOE+000 4.151E-003 Particulates (Curies)
Isotope October November December Total Total 0.OOOE+000 O.OOOE+00O 0.OOOE+000 0.OOOE+000 Halogens (Curies)
Isotope October November December Total Total 0.OOOE+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 Page 16 of61
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2002 4th Quarter Gaseous Release Total of all Releases Summary October November December Total Total Noble Gases (Ci) 3.516E-003 6.348E-004 O.OOOE+000 4.151E-003 Total Halogens (Ci) O.OOOE+000 0.000E+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 1.886E-004 2.864E-004 O.OOOE+000 4.751E-004 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 17 of 61
Table 2.3B Annual Radioactive Effluent Release Report 2002 1st Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope January February March Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Particulates (Curies)
Isotope January February March Total Total O.OOOE+000 0.000E+000 0.000E+000 O.OOOE+000 Halogens (Curies)
Isotope January February March Total Total O.OOOE+000 0.000E+000 0.000E+000 O.OOOE+000 Page 18 of61
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2002 1st Quarter Gaseous Release Continuous Mode Only Summary Januwiry February March Tcital Total Noble Gases (Ci) O.OOOE+000 0.000E+000 0.000E+000 O.OOOE+000 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 0.000E+000 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.000E+000 O.OOOE+000 O.OOOE+000 0.000E+000 Total Tritium (Ci) O.OOOE+000 3.655E-001 3.066E-001 6.720E-001 Total Particulate Gross Alpha (Ci) O.OOOE+000 0.000E+000 O.OOOE+000 0.000E+000 Page 19 of 61
L Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2002 2nd Quarter Gaseous Release Continuous Mode Only L Noble Gasses (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Particulates (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope April May June Total Total 0.000E+000 O.OOOE+000 O.OOOE+000 0.000E+000 Page 20 of 61
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2002 2nd QuarterGaseous Release Continuous Mode Only Summary April May June Total Total Noble Gases (Ci) 0.000E+000 O.OOOE+000 0.000E+000 O.OOOE+000 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 6.828E-001 2.712E-001 O.OOOE+000 9.540E-001 Total Particulate Gross Alpha (Ci) O.OOOE+000 0.000E+000 O.OOOE+000 O.OOOE+000 Page 21 of 61
Table 2.3B (con't)
Annual Radioactive Effluent Release Report 2002 3rd Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope July August September Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 L
Particulates (Curies)
L Isotope July August September Total O.OOOE+000 O.OOOE+000 O.OOOE+000 L Total 0.000E+000 Halogens (Curies)
Isotope July August September Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 22 of 61
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2002 3rd Quarter Gaseous Release Continuous Mode Only Summary July August September Total Total Noble Gases (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 0.000E+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 0.000E+000 0.000E+000 O.OOOE+000 Total Tritium (Ci) 0.000E+000 2.998E-001 4.375E-001 7.374E-001 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 0.000E+000 Page 23 of 61
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2002 4th Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope October November December Total Total O.OOOE+000 0.000E+000 0.000E+000 0.000E+000 Particulates (Curies)
Isotope October November December Total Total 0.000E+000 0.000E+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope October November December Total Total O.OOOE+000 0.000E+000 O.OOOE+000 O.OOOE+000 Page 24 of 61
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2002 4th Quarter Gaseous Release Continuous Mode Only Summary October November December Total Total Noble Gases (Ci) O.OOOE+000 0.000E+000 O.OOOE+000 O.OOOE+000 Total Halogens (Ci) O.OOOE+000 0.000E+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) O.OOOE+000 O.OOOE+000 0.000E+000 O.OOOE+000 Total Particulate Gross Alpha (ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 0.000E+000 Page 25 of 61
Table 2.3C Annual Radioactive Effluent Release Report 2002 1st Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope January February March Total Ar-41 2.262E-005 O.OOOE+000 O.OOOE+000 2.262E-005 Xe-133 8.740E-005 O.OOOE+000 3.016E-003 3.103E-003 Xe-135 3.775E-005 O.OOOE+000 O.OOOE+000 3.775E-005 Total 1.478E-004 O.OOOE+000 3.016E-003 3.163E-003 Particulates (Curies)
Isotope January February March Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope January February March Total Total 0.000E+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 26 of 61
L Table 2.3C (Con't)
L Annual Radioactive Effluent Release Report 2002 1st Quarter Gaseous Release Batch Mode Only L
Summary March T()tal F'ebhrarv L Janu Cas
.,y , v Total Noble 3.163E-003 L Gases (Ci) 1.478E-004 0.OOOE+000 3.0166E-003 Total Halogens 0.OOOE+000 O.000E+000 0.OOOE+000 L (Ci) 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days L (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 O.OOOE+000 Total Tritium 2.724E-005 1.530E-005 0.OOOE+000 1.194E-005 (Ci)
L Total Particulate Gross Alpha L (Ci) 0.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 L
L L
L Page 27 of 61
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2002 2nd Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope April May June Total 0.000E+000 1.009E-004 O.OOOE+000 1.009E-004 Xe-133m 3.338E-004 5.469E-003 9.804E-005 5.901E-003 Xe-133 O.OOOE+000 7.374E-005 O.OOOE+000 7.374E-005 Xe-135 Total 3.338E-004 5.644E-003 9.804E-005 6.076E-003 Particulates (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 28 of 61
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2002 2nd Quarter Gaseous Release Batch Mode Only Summary April May June Total Total Noble Gases (Ci) 3.338E-004 5.644E-003 9.804E-005 6.076E-003 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 1.450E-005 4.878E-004 3.949E-005 5.418E-004 Total Particulate Gross Alpha (Ci) 0.000E+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 29 of 61
Table 2.3C (con't)
Annual Radioactive Effluent Release Report 2002 3rd Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope July August September Total Ar-41 0.000E+000 1.643E-003 0.000E+000 1.643E-003 Kr-85m 0.000E+000 3.663E-004 O.OOOE+000 3.663E-004 Kr-88 0.000E+000 3.408E-004 0.000E+000 3.408E-004 Xe-133 O.OOOE+000 6.213E-003 2.695E-003 8.908E-003 Xe-135 0.000E+000 3.674E-003 8.863E-006 3.683E-003 Total 0.OOOE+000 1.224E-002 2.704E-003 1.494E-002 Particulates (Curies)
Isotope July August September Total Total 0.OOOE+000 O.OOOE+O000 0.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope July August September Total Total 0.OOO3+O00O 0.OOOE+000 0.OOOE+000 O.OOOE+000 Page 30 of 61
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2002 3rd Quarter Gaseous Release Batch Mode Only Summary July August September Total Total Noble Gases (Ci) O.OOOE+000 1.224E-002 2.704E-003 1.494E-002 Total Halogens (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 0.000E+000 O.OOOE+000 0.000E+000 Total Tritium (Ci) O.OOOE+000 1.024E-004 1.479E-004 2.503E-004 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 31 of 61
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2002 4th Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope October November December Total Ar-41 6.988E-004 O.OOOE+000 0.OOOE+000 6.988E-004 Kr-85m 4.389E-005 O.OOOE+000 O.OOOE+000 4.389E-005 Kr-87 1.722E-005 0.000E+000 0.OOOE+000 1.722E-005 Kr-88 5.83 lE-005 O.OOOE+000 0.OOOE+000 5.83 1E-005 Xe-133 2.376E-003 6.348E-004 0.OOOE+000 3.01 1E-003 Xe-135 3.217E-004 0.OOOE+000 0.OOOE+000 3.217E-004 Total 3.516E-003 6.348E-004 0.OOOE+000 4.151E-003 Particulates (Curies)
Isotope October November December Total Total 0.000E+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Halogens (Curies)
Isotope October November December Total Total 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Page 32 of 61
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2002 4th Quarter Gaseous Release Batch Mode Only Summary October November December Total Total Noble Gases (Ci) 3.516E-003 6.348E-004 O.OOOE+000 4.151lE-003 Total Halogens (Ci) 0.000E+000 0.000E+000 O.OOOE+000 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) O.OOOE+000 0.000E+000 0.000E+000 O.OOOE+000 L Total Tritium (Ci) 1.886E-004 2.864E-004 0.000E+000 4.751E-004 Total Particulate Gross Alpha (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 33 of 61
Table 2.4 Annual Radioactive Effluent Release Report 2002 Dose From Gaseous Effluents The offsite dose limits from radioactive materials in gaseous effluents are specified in Section 3/4.4 of the Kewaunee ODCM and can be summarized as follows:
Whole Body Skin Limit Gamma Beta Organ Quarterly 5.0 mRad 10.0 inRad 7.5 niRem Annual 10.0 mRad 20.0 mRad 15.0 mRem The total release of gaseous effluents during each quarter of 2002 was within limits. The following offsite doses were calculated using equations 2.7, 2.8, and 2.11 from the Kewaunee ODCM.
Calculated offsite doses versus quarterly limits are shown below:
1st Qtr 2nd Qtr 3rd Qtr 4th Qtr
- 1. Gamma-Whole Body Specification (mRads) 5.OOOE+000 5.OOOE+000 5.000E+000 5.000E+000 Actual Dose (mRads) 1.573E-007 2.576E-007 3.552E-006 1.053E-006
% of Specification 3.146E-006 5.153E-006 7.104E-005 2.106E-005
- 2. Beta-Skin Specification (mRads) 1.000E+001 1.000E+001 1.000E+001 1.000E+001 Actual Dose (mRads) 3.909E-007 7.448E-007 2.913E-006 7.623E-007
% of Specification 3.909E-006 7.448E-006 2.913E-005 7.623E-006
- 3. Ingestion Pathway-Organ Specification (niRems) 7.500E+000 7.500E+000 7.500E+000 7.500E+000 Actual Dose (mRems) 1.420E-005 2.016E-005 1.558E-005 1.004E-008
% of Specification 1.893E-004 2.689E-004 2.078E-004 1.338E-007 Liver Liver Liver Liver Page 34 of 61
Table 2.4 (Con't)
Annual Radioactive Effluent Release Report 2002 Dose From Gaseous Effluents In addition, the cumulative annual offsite doses for the period January 1 - December 31, 2002 versus the ODCM annual limits were:
Annual
- 1. Gamma-Whole Body Specification (mRads) 1.000E+001 Actual Dose (mRads) 5.020E-006
% of Specification 5.020E-005
- 2. Beta-Skin Specification (mRads) 2.OOOE+001 Actual Dose (mRads) 4.81 IE-006
% of Specification 2.405E-005
- 3. Ingestion Pathway-Organ Specification (mRems) 1.500E+001 Actual Dose (mRems) 4.996E-005
% of Specification 3.330E-004 Liver Page 35 of 61
3.0 LIQUID EFFLUENTS 3.1 Lower Limits of Detection (LLD) for Liquid Effluents Liquid radioactive effluents are released as both batch releases and continuous releases. Each batch is sampled prior to release and analyzed for gamma emitters and tritium. A fraction of each sample is retained for a monthly proportional composite which is then analyzed for Gross Alpha, Strontium 89, Strontium 90 and Iron 55.
The LLD's for liquid batch release radioanalyses, as listed in Table 4.3 of the Kewaunee Nuclear Power Plant Off-Site Dose Calculation Manual, are:
Analysis LLD (uCi/ml)
Principal Gamma Emitters 1.00 E-06 Iodine 131 1.00 E-06 Tritium 1.00 E-05 Gross Alpha 5.00 E-07 Strontium 89, 90 5.00 E-08 Iron 55 1.00 E-06 The actual obtained "a priori" LLD values for batch releases are shown below.
Isotope I st Quarter 2nd Quarter 3rd Quarter 4th Quarter Average a priori LLD (gCi/ml)
Mn-54 6.56E-10 6.56E-10 6.56E-08 6.56E-1 0 1.69E-08 Fe-59 1.45E-09 1.44E-09 1.45E-09 1.45E-09 1.45E-09 Co-58 6.45E-10 6.44E- 0 6.45E-10 6.45E-10 6.45E-10 Co-60 9.57E- 10 9.56E-10 9.57E-1 0 8.62E-08 2.23E-08 Zn-65 1.63E-09 1.63E-07 1.63E-09 1.63E-09 4.20E-08 Mo-99 4.65E-09 4.64E-09 4.65E-07 4.65E-09 1.20E-07 Cs-134 5.17E-08 7.83E-08 5.71E-08 5.17E- 10 4.69E-08 Cs-137 6.38E-08 6.38E-10 6.38E-10 6.38E-10 1.64E-08 Ce-141 3.90E-08 5.51E-08 l.lOE-07 3.90E-1 0 5.1 lE-08 Ce-144 1.76E-09 1.75E-09 1.76E-09 1.76E-07 4.53E-08 1-131 4.45E-08 6.97E-08 4.03E-10 4.03E-1 0 2.88E-08 H-3 3.43E-06 3.12E-06 3.66E-06 3.77E-06 3.50E-06 Sr-89 1.43E-08 3.53E-08 1.83E-08 1.23E-08 2.01E-08 Sr-90 1.05E-08 7.37E-09 7.53E-09 7.60E-09 8.25E-09 Gross Alpha 7.57E-09 5.83E-09 6.47E-09 7.50E-09 6.84E-09 Fe-55 9.23E-07 9.30E-07 7.73E-07 6.20E-07 8.12E-07 Page 36 of 61
Continuous liquid releases are grab sampled weekly and analyzed for principal gamma emitters. A fraction of each weekly sample is retained for a monthly proportional composite which is then analyzed for Tritium, Gross Alpha, Strontium 89, Strontium 90 and Iron 55.
The LLD's for liquid continuous release radioanalyses, as listed in Table 4.3 of the Kewaunee Nuclear Power Plant Off-Site Dose Calculation Manual, are:
Analysis LLD (ipCi/ml)
Principal Gamma Emitters 5.00 E-07 Iodine 131 1.00 E-06 Tritium 1.00 E-05 Gross Alpha 5.00 E-07 Strontium 89, 90 5.00 E-08 Iron 55 1.00 E-06 The actual obtained "a priori" LLD values for continuous releases are shown below.
Isotope 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Average a priori LLD (PCi/mI)
Mn-54 1.09E-08 2.67E-08 1.09E-10 1.55E-08 1.33E-08 Fe-59 2.41 E-08 2.41E-10 2.41E-10 6.82E-08 2.32E-08 Co-58 3.56E-08 2.75E-08 1.86E-08 1.07E-08 2.3 1E-08 Co-60 2.26E-08 4.84E-08 2.76E-08 1.99E-08 2.96E-08 Zn-65 2.72E-10 4.55E-08 5.12E-08 2.72E-10 2.43E-08 Mo-99 2.1 IE-07 l.99E-07 7.79E-08 1.27E-07 1.54E-07 Cs-134 8.61E-1 I 3.38E-08 8.61E-1 1 3.66E-08 1.77E-08 Cs-137 1.06E-l 0 4.18E-08 2.86E-08 1.36E-07 5.17E-08 Ce-141 1.95E-08 6.50E-1 1 1.84E-08 1.72E-08 1.38E-08 Ce-144 7.18E-08 9.71E-08 1.31 E-07 2.93E-10 7.50E-08 I-131 1.69E-08 2.27E-08 1.34E-08 2.27E-08 1.89E-08 H-3 3.43E-06 3.12E-06 3.66E-06 3.77E-06 3.50E-06 Sr-89 1.35E-08 2.97E-08 1.82E-08 1.17E-08 1.83E-08 Sr-90 7.57E-09 6.13E-09 7.92E-09 7.23E-09 7.21 E-09 Gross Alpha 5.85E-09 6.18E-09 7.73E-09 5.1 OE-09 6.22E-09 Fe-55 9.52E-07 2.35E-06 7.65E-07 6.28E-07 1.17E-06 Page 37 of 61
3.2 Liquid Batch Release Statistics The following is a summation of all liquid batch releases made during 2002.
Release Type AN1 UIlIUJ Gallons Released A SGBT Monitor Tk. 12 105900.0 B SGBT Monitor Tk. 12 107562.0 A CVC Monitor 3 18025.0 B CVC Monitor 4 20545.0 miscellaneous 1 911.0 Both WCTs 7 10405.0 Total time for all batch releases ............. 14586.0 Min.
Maximum time for a batch release .............. 694.0 Min.
Minimum time for a batch release .............. 1.0 Min.
Average time for a batch release .............. 374.0 Min.
3.3 Liquid Effluent Data The following Table 3.1 presents a quarterly summation of the total activity released and average concentration for all liquid effluents. It also presents the gross alpha activity released, volume of waste released and volume of dilution water used. Tables 3.2 and 3.3 are monthly summations of the same information in Table 3.1. Table 3.2 contains the quantity of the individual isotopes released to the unrestricted area for batch releases. Table 3.3 presents a monthly summation of gross radioactivity, tritium, gross alpha and isotopic activity for the secondary blowdown and leakage releases. It also presents the monthly total volume for these releases and dilution volumes. Table 3.4 presents the doses from liquid effluents for each quarter and the calculated doses this year from liquid effluents.
Page 38 of 61
TABLE 3.1 Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Summation of all Releases 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Fission and Activation Products Total Release Excluding H3 and Dissolved Gases (Ci) 2.424E-002 1.1 52E-002 7.489E-003 7.318E-003 Average Concentration (PCi/mi) 2.422E-010 7.111E-011 *3.673E-01 1 4.325E-0 1I Tritium Total Release (Ci) 1.016E+001 5.402E+001 9.431 E+000 6.486E+001 Average Concentration (RlCi/ml) 1.015E-007 3.334E-007 4.625E-008 3.834E-007
% of Tech. Spec.
Limit(3.OE-3 pCi/ml) 3.383E-003 1.11l E-002 1.542E-003 1.278E-002 Dissolved Gases Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Average Concentration (RCi/mi) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000
% of Tech. Spec.
Limit(2.OE-4 pCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Gross Alpha Activity Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released Batch (liters) 1.831E+005 3.379E+005 2.034E+005 2.725E+005 Continuous (liters) 4.464E+007 2.655E+007 2.099E+007 2.520E+007 Total (liters) 4.482E+007 2.689E+007 2.119E+007 2.547E+007 Volume of Dilution Water Batch (liters) 1.969E+009 4.920E+009 3.331 E+009 4.579E+009 Continuous (liters) 9.812E+010 1.571E+01 1 2.006E+01 1 1.646E+01 I Total (liters) I.OOIE+O II 1.620E+01 I 2.039E+O II 1.692E+01 I Page 39 of 61
TABLE 3.2A Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases January February March Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 3.570E-003 4.730E-003 1.355E-003 9.655E-003 Avg. Conc.
(,RCilml) 6.196E-009 4.673E-009 3.559E-009 Tritium Total Release (Ci) 1.1 82E+000 5.121E+000 3.855E+000 1.016E+001 Avg. Conc.
(PCi/ml) 2.052E-006 5.059E-006 1.012E-005 Dissolved Gases Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.
(RCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Gross Alpha Activity Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.
(RCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released (liters) 6.754E+004 7.899E+004 3.654E+004 1.831E+005 Volume of Dilution Water (liters) 5.761E+008 1.012E+009 3.808E+008 1.969E+009 Page 40 of 61
TABLE 3.2A (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases Isotope (Ci) January February March Total H-3 1.182E+O00 5.121E+000 3.855E+000 1.016E+O01 Mn-54 1.719E-005 2.901E-005 1.794E-005 6.414E-005 Fe-55 8.780E-004 l .501E-003 4.750E-004 2.854E-003 Co-58 1.205E-003 1.954E-003 4.95 1E-004 3.654E-003 Fe-59 1.446E-004 2.081E-005 0.OOOE+000 1.654E-004 Co-60 5.994E-004 5.151E-004 2.702E-004 1.385E-003 Sr-89 O.OOOE+O00 0.OOOE+000 2.558E-007 2.558E-007 Sr-90 2.364E-007 1.027E-006 O.OOOE+000 1.263E-006 Zr-95 5.236E-005 O.OOOE+O00 O.OOOE+000 5.236E-005 Nb-95 1.560E-004 5.883E-005 3.038E-005 2.452E-004 Ag-i lOm 4.675E-004 3.699E-004 6.648E-005 9.038E-004 Sn-1 13 4.953E-005 0.OOOE+O0O O.OOOE+000 4.953E-005 Sb-124 O.OOOE+O0O 4.339E-005 0.OOOE+000 4.339E-005 Sb-125 O.OOOE+OO0 2.372E-004 O.OOOE+000 2.372E-004 Total 1.186E+O00 5.126E+000 3.856E+000 1.01 7E+OOI Page 41 of 61
TABLE 3.2B Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases April May June Total Gross Radioactivity Total Release Excluding H3 and Dissolved 2.189E-003 7.063E-004 6.442E-004 3 .540E-003 Gases (Ci)
Avg. Conc.
(jiCi/ml) 1.171E-009 3.297E-010 7.091E-010 Tritium Total Release 1.322E+001 3.699E+001 3.729E+000 5.393E+001 (Ci)
Avg. Conc.
(jiCi/ml) 7.069E-006 1.727E-005 4.1 05E-006 Dissolved Gases Total Release O.OOOE+000 0.OOOE+000 0.OOOE+000 (Ci) O.OOOE+000 Avg. Conc.
(AiCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Gross Alpha Activity Total Release O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 (Ci)
Avg. Conc.
(giCi/mi) O.OOOE+000 O.OOOE+000 0.OOOE+000 Volume of Waste Released 1.772E+005 1.313E+005 2.930E+004 3.379E+005 (liters)
Volume of Dilution Water 1.870E+009 2.142E+009 9.085E+008 4.920E+009 (liters)
Page 42 of 61
TABLE 3.2B (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases Isotope (Ci) April May June Total H-3 1.322E+00I 3.699E+O01 3.729E+000 5.393E+O01 Fe-55 1.152E-003 4.597E-004 4.687E-004 2.080E-003 Co-58 3.039E-004 8.861E-005 2.473E-005 4.173E-004 Co-60 3.897E-004 4.218E-005 1.092E-005 4.428E-004 Sr-89 4.076E-006 1.576E-006 4.101E-007 6.062E-006 Sr-90 O.OOOE+OO0 0.OOOE+000 2.080E-007 2.080E-007 Ag-llOm 3.187E-004 1.142E-004 8.733E-005 5.202E-004 Sn-1 13 2.107E-005 0.OOOE+OO0 O.OOOE+000 2.107E-005 Sb-125 O.OOOE+O0O O.OOOE+000 5.185E-005 5.185E-005 Total 1.322E+001 3.699E+001 3.730E+000 5.394E+001 Page 43 of 61
TABLE 3.2C Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases July August September Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 1.61 OE-003 8.044E-004 6.421E-004 3.057E-003 Avg. Conc.
(ACi/ml) l.1 lOE-009 9.239E-010 6.357E-010 Tritium Total Release (Ci) 5.221 E+OOO 1.948E+000 2.248E+O00 9.417E+O0O Avg. Conc.
(PCi/mi) 3.600E-006 2.237E-006 2.226E-006 Dissolved Gases Total Release (Ci) O.OOOE+OOO O.OOOE+000 O.OOOE+OO0 O.OOOE+000 Avg. Conc.
(pCi/ml) O.OOOE+OOO O.OOOE+000 O.OOOE+000 Gross Alpha Activity Total Release (Ci) O.OOOE+O00 0.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Cone.
(IiCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released (liters) 6.659E+004 6.492E+004 7.189E+004 2.034E+005 Volume of Dilution Water (liters) 1.451 E+009 8.706E+008 I .OlOE+009 3.331 E+009 Page 44 of 61
TABLE 3.2C (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases Isotope (Ci) July August September Total H-3 5.221E+000 1.948E+000 2.248E+000 9.417E+000 Fe-55 3.196E-004 3.116E-004 1.078E-004 7.391E-004 Co-58 5.205E-004 1.125E-004 3.960E-005 6.726E-004 Co-60 1.253E-004 4.586E-005 8.213E-006 1.794E-004 Sr-90 1.199E-007 9.089E-008 7.908E-008 2.898E-007 Ag-i lOm 5.685E-004 2.197E-004 2.061E-004 9.943E-004 Sb-125 7.639E-005 1.147E-004 2.803E-004 4.713E-004 Total 5.223E+000 1.949E+000 2.249E+000 9.420E+000 Page 45 of 61
TABLE 3.2D Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases October November December Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 9.030E-004 1.156E-003 1.180E-003 3.239E-003 Avg. Conc.
(pCi/ml) 1.056E-009 8.079E-010 5.148E-010 Tritium Total Release (Ci) 1.821E+000 1.483E+000 6.152E+001 6.483E+001 Avg. Conc.
(gCi/mi) 2.128E-006 1.037E-006 2.684E-005 Dissolved Gases Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.
(.tCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Gross Alpha Activity Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.
(JACi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released (liters) 3.372E+004 6.851E+004 1.703E+005 2.725E+005 Volume of Dilution Water (liters) 8.555E+008 1.431E+009 2.292E+009 4.579E+009 Page 46 of 61
TABLE 3.2D (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Batch Releases Isotope (Ci) October November December Total H-3 1.821E+000 1.483E+000 6.152E+001 6.483E+001 Fe-55 3.372E-004 2.192E-004 2.895E-004 8.460E-004 Co-58 5.459E-005 7.175E-005 6.984E-005 1.962E-004 Co-60 1.315E-005 2.337E-005 2.367E-005 6.019E-005 Sr-89 6.744E-008 1.370E-007 O.OOOE+000 2.045E-007 Sr-90 3.372E-008 O.OOOE+000 2.214E-007 2.55 1E-007 Ag-lOim 1.497E-004 1.288E-004 1.599E-004 4.383E-004 Sb-125 3.483E-004 7.106E-004 6.360E-004 1.695E-003 Cs-137 O.OOOE+000 2.092E-006 9.501E-007 3.042E-006 Total 1.822E+000 1.484E+000 6.152E+001 6.483E+001 Page 47 of 61
L TABLE 3.3A Annual Radioactive Effluent Release Report 2002 I Liquid Effluents - Continuous Releases January February March Total IL Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 4.346E-005 1.188E-002 2.654E-003 1.458E-002 I Avg. Conc.
(iLCilml) 1.286E-012 3.893E-010 7.854E-01 1 L
Tritium Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.
L (PCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 i Dissolved Gases Total Release O.OOOE+000 L (Ci)
Avg. Conc.
O.OOOE+000 O.OOOE+000 O.OOOE+000 (ItCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Gross Alpha Activity L
Total Release (Ci) O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Avg. Conc.
L (1tCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released (liters) 1.642E+007 1.846E+007 9.754E+006 4.464E+007 Volume of Dilution Water (liters) 3.380E+010 3.053E+010 3.380E+010 9.812E+010 Page 48 of 61
TABLE 3.3A (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases Isotope (Ci) January February March Total Fe-55 O.OOOE+000 1.169E-002 2.625E-003 1.43 1E-002 Sr-89 2.813E-005 1.973E-004 1.928E-005 2.447E-004 Sr-90 1.534E-005 O.OOOE+000 1.048E-005 2.581E-005 Total 4.346E-005 1.1 88E-002 2.654E-003 1.458E-002 Page 49 of 61
L L TABLE 3.3B Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases Apri i May June Tcotal Gross Radioactivity i-Total Release Excluding H3 and Dissolved 1.215E-003 7.984E-003 L Gases (Ci) 2.368E-003 4.401E-003 I Avg. Conc.
(gCi/ml) 5.852E-0 1I 8.589E-011 1.857E-01 1 L
Tritium Total Release 7.896E-002 O.OOOE+000 8.848E-002 (Ci) 9.518E-003 Avg. Conc.
L (glCilml) 2.352E-010 1.541 E-009 O.OOOE+000 Dissolved Gases Total Release L (Ci)
Avg. Conc.
O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 (JACi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 L.
Gross Alpha Activity L Total Release 0.OOOE+000 L (Ci)
Avg. Conc.
O.OOOE+000 O.OOOE+000 O.OOOE+000 (pCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released 1.138E+007 7.877E+006 2.655E+007 L (liters) 7.300E+006 Volume of Dilution Water 5.124E+010 6.541E+010 1.571E+01lI (liters) 4.047E+010 Page 50 of 61
TABLE 3.3B (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases Isotope (Ci) April May June Total H-3 9.5188E-003 7.896E-002 0.OOOE+000 8.848E-002 Fe-55 2.271E-003 4.180E-003 1.202E-003 7.653E-003 Sr-89 9.704E-005 2.207E-004 O.OOOE+000 3.177E-004 Sr-90 O.OOOE+000 O.OOOE+000 1.295E-005 1.295E-005 Total 1.189E-002 8.336E-002 1.215E-003 9.646E-002 Page 51 of 61
L L TABLE 3.3C Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases L Total July August September L.
Gross Radioactivity I Total Release Excluding H3 and Dissolved 1.942E-004 3.370E-003 8.677E-004 4.432E-003 Gases (Ci)
Avg. Conc.
(RCilml) 2.873E-012 4.986E-01 1 1.326E-01 1 Tritium L Total Release 5.947E-003 O.OOOE+000 7.836E-003. 1.378E-002 (Ci)
Avg. ConC.
(iCi/ml) 8.799E-01 1 O.OOOE+000 1.198E-010 Dissolved Gases L
Total Release O.OOOE+000 L
L (Ci)
Avg. Conc.
O.OOOE+000 O.OOOE+000 O.OOOE+000 (RCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 L
Gross Alpha Activity U
Total Release O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 (Ci)
L Avg. Conc.
(PCi/ml) O.OOOE+000 O.OOOE+000 O.OOOE+000 Volume of Waste Released 6.679E+006 7.737E+006 6.569E+006 2.099E+007 (liters)
Volume of Dilution Water (liters) 6.759E+010 6.759E+010 6.541 E+010 2.006E+01 I Page 52 of 61
TABLE 3.3C (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases Isotope (Ci) July August September Total H-3 5.947E-003 0.OOOE+000 7.836E-003 1.378E-002 Fe-55 1.853E-004 3.350E-003 8.499E-004 4.385E-003 Sr-89 O.OOOE+000 8.354E-006 1.447E-005 2.283E-005 Sr-90 8.910E-006 1.205E-005 3.316E-006 2.428E-005 Total 6.141E-003 3.370E-003 8.704E-003 1.822E-002 Page 53 of 61
L TABLE 3.3D L Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases L. Octo ber November December Tcotal L Gross Radioactivity L Total Release Excluding H3 and Dissolved 4.079E-003 L Gases (Ci) 9.046E-004 1.517E-005 3.159E-003 Avg. Conc.
(gtCi/ml) 1.338E-01 1 2.577E-013 8.280E-01 1 L
Tritium L Total Release 4.675E-004 3 .657E-002 (Ci) 3.610E-002 O.OOOE+000 Avg. Conc.
L (ACi/ml) 5.341E-010 0.OOOE+000 1.225E-01 I Dissolved Gases L
Total Release 0.OOOE+O000 (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.
(gCi/ml) O.OOOE+000 0.OOOE+000 0.000E+000 L Gross Alpha Activity Total Release 0.OOOE+000 (Ci) O.OOOE+000 0.OOOE+000 0.OOOE+000 Avg. Conc.
L (tiCi/ml) O.OOOE+000 0.OOOE+000 0.000E+000 L Volume of Waste Released 9.685E+006 2.520E+007 (liters) 8.449E+006 7.062E+006 L Volume of Dilution Water 3.816E+010 1.646E+01 I (liters) 6.759E+010 5.887E+010 Page 54 of 61
TABLE 3.3D (Con't)
Annual Radioactive Effluent Release Report 2002 Liquid Effluents - Continuous Releases Isotope (Ci) October November December Total H-3 3.610E-002 O.OOOE+000 4.675E-004 3.657E-002 Fe-55 8.892E-004 O.OOOE+000 3.151E-003 4.040E-003 Sr-89 O.OOOE+000 O.OOOE+000 6.673E-006 6.673E-006 Sr-90 1.539E-005 1.517E-005 1.983E-006 3.254E-005 Total 3.700E-002 1.517E-005 3.627E-003 4.065E-002 Page 55 of 61
Table 3.4 Annual Radioactive Effluent Report 2002 Dose From Liquid Effluents The dose to a member of the public from total liquid radioactive releases for each quarter was below the ODCM limits of 1.5 mrems to the total body and less than or equal to 5 mrems to any organ.
Additionally, the dose to a member of the public from total liquid radioactive releases for the year was below the ODCM limits of 3 mrems to the total body and less than or equal to 10 mrems to any organ.
Instantaneous release concentrations are limited by the individual radionuclide concentrations established in 10 CFR 20, Appendix B, for unrestricted areas. During the report period, none ofthe isotopes released exceed the concentrations specified in Appendix B. The following offsite doses were calculated using equation 1.5 from the Kewaunee ODCM.
Organ Dose Quarterly Percent 1st Qtr Dose Total Limit of Limit mRem niRem Total Body 1.232E-004 1.5 0.01 Bone 6.326E-005 5.0 0.00 Liver 1.341E-004 5.0 0.00 Thyroid 7.379E-005 5.0 0.00 Kidney 7.699E-005 5.0 0.00 Lung 9.233E-005 5.0 0.00 GI-LLI 8.593E-003 5.0 0.17 Organ Dose Quarterly Percent 2nd Qtr Dose Total Limit of Limit mRem mRem Total Body 3.702E-004 1.5 0.02 Bone 2.983E-005 5.0 0.00 Liver 3.797E-004 5.0 0.01 Thyroid 3.587E-004 5.0 0.01 Kidney 3.587E-004 5.0 0.01 Lung 3.687E-004 5.0 0.01 GI-LLI 4.332E-004 5.0 0.01 Page 56 of 61
Table 3.4 (Con't)
Annual Radioactive Effluent Report 2002 Dose From Liquid Effluents Organ Dose Quarterly Percent 3rd Qtr Dose Total Limit of Limit mRem mRem Total Body 4.4188E-005 1.5 0.00 Bone 3.708E-005 5.0 0.00 Liver 4.341E-005 5.0 0.00 Thyroid 3.423E-005 5.0 0.00 Kidney 3.425E-005 5.0 0.00 Lung 3.872E-005 5.0 0.00 GI-LLI 6.771E-005 5.0 0.00 Organ Dose Quarterly Percent 4th Qtr Dose Total Limit of Limit mRem mRem Total Body 5.361E-004 1.5 0.04 Bone 2.882E-004 5.0 0.01 Liver 5.218E-004 5.0 0.01 Thyroid 4.590E-004 5.0 0.01 Kidney 4.668E-004 5.0 0.01 Lung 4.837E-004 5.0 0.01 GI-LLI 5.027E-004 5.0 0.01 Calculated Dose This Year Organ Dose Quarterly Percent Total Limit of Limit mRem mRem Total Body 1.074E-003 3.0 0.04 Bone 4.183E-004 10.0 0.00 Liver 1.079E-003 10.0 0.01 Thyroid 9.258E-004 10.0 0.01 Kidney 9.368E-004 10.0 0.01 Lung 9.834E-004 10.0 0.01 GI-LLI 9.597E-003 10.0 0.10 Page 57 of 61
4.0 UNPLANNED RELEASES No unplanned releases were made from the Kewaunee Plant during the report period.
The January-June 1991 Semi-Annual Effluent Release Report described an unplanned release which occurred on April 25, 1991. Offsite doses attributed to this release were well below the established ODCM (Technical Specifications at the time) limits.
As corrective action, WPSC stated in this report that valves WG-301 and WG-302 were scheduled to be replaced during 1992. Also, a new vent line was added between valves WG-300 and WG-301 to allow local leak rate testing with the Waste Gas Decay Tanks isolated. The valves were to be replaced with like-for-like replacements. However, after receipt inspection, the replacement valves failed to pass the seat leakage tests. WPSC is continuing to evaluate options associated with these valves and will continue to provide status updates in the Effluent Release Reports until resolution of this incident and completion of the corrective actions. A plant design change request, DCR-2349, was issued to address this concern.
5.0 METEOROLOGICAL DATA Meteorological data for 2002 is retained on file at the Kewaunee Nuclear Power Plant. The data on file includes a continuous strip chart recording and a 15-minute interval listing of wind speed, wind direction and atmospheric stability. This is more conservative than the requirements of ODCM Section 3/4.7. See Appendix A for missing meteorological data and the joint frequency distribution tables.
6.0 SOLID WASTE DISPOSAL Table 6.1 is a summation of solid wastes shipped during 2002. Presented are the types of wastes, major nuclide composition, disposition of the wastes and shipping containers used.
The containers utilized at Kewaunee Nuclear Power Plant have the following volumes:
High Integrity Container (HIC) 158 ft3 LSA Box (B-25) 98 ft3 Compactor Boxes 50 ft3 DOT-17H Drum 7.5 ft3 A composite sample from the 1993 dewatered resin shipments was analyzed by a contractor for transuranic nuclides. The results showed an average transuranic concentration of 4.24 E-2 nanocuries/gram, well within the disposal site limit of 10 nanocuries/gram.
Table 6.1 contains the radionuclide content (curies) and percent abundance for each type of waste.
Page 58 of 61
Table 6.1 Annual Radioactive Effluent Report 2002 Solid Waste and Irradiated Fuel Shipments Isotopes denoted by an asterisk (*) in Table 6.1 are correlated values.
A. Solid Waste Shipped Off-Site for Burial or Disposal (Not Irradiated Fuel - m3 is actual waste volume not burial volume)
- 1. Type of Waste Unit Quantity
- a. Dewatered resin m3 3.94E+00 Container: HIC Ci 3.30E+01
- b. Dewatered filter media m3 None Container: HIC Ci None
- c. DAW (Compactible) m3 9.12E+01 Container: Compactor Box Ci 5.98E-01
- d. DAW (Non-Compactible) m3 None Container: Compactor Box Ci None Average Transuranics shipped (all shipments): 7.38E-01 nCi/g
- 2. Estimate of Major Nuclide by Composition (By Type of Waste) % Ci
- a. Dewatered resin 100% 3.30E+01 Mn-54 4.99E+00 1.65E+00 Co-58 7.29E-01 2.41E-01 Co-60 4.39E+01 1.45E+01 Cs-137 1.40E+00 4.63E-01 Sb-125 2.29E+00 7.58E-01
- Fe-SS 8.78E+00 2.90E+00
- C-14 4.81E-02 1.59E-02 Ni-59 3.57E-01 1.18E-01
- Pu-241 3.84E-02 1.27E-02 T 1.92E-02 6.34E-03
- Ni-63 3. 72E+01 1.23E+01 Np-237 l.OOE-01 3.31E-02 Ce-144 1.20E-01 3.95E-02
- b. Dewatered filter media None None Page 59 of 61
- c. DAW (Compactible) 100% 5.98E-01 Mn-54 1.61E+00 9.65E-03 Co-58 1.34E+01 8.02E-02 Co-60 2.60E+01 1.55E-01 Zr-95 3.78E-01 2.26E-03 Nb-95 7.30E-01 4.37E-03 Ag-110m 1.41E-01 8.45E-04 Cs-137 1.33E-01 7.98E-04 Sb-125 8.48E-01 5.07E-03
- Fe-55 1.31E+01 7.85E-02
- C-14 3.79E-02 2.27E-04 Ni-59 3.67E-01 2.19E-03
- Pu-241 4.77E-02 2.85E-04
- Cm-242 1.19E-04 7.11E-07 T 1.02E-01 6.12E-04
- Ni-63 4.14E+01 2.48E-01 Zn-65 2.8 1E-01 1.68E-03 Be-7 1.49E-02 8.92E-05 K-40 1.20E+00 7.20E-03 U-233 2.57E-04 1.54E-06 Np-237 7.49E-02 4.48E-04 Ce-144 9.40E-02 5.62E-04
- d. DAW (Non-Compactible) None None
- 3. Solid Waste Disposition
- a. Date of Shipment Mode of Transportation Destination 06/06/02 R & R Trucking (Flatbed) US Ecology Oak Ridge, TN 08/06/02 CNSI 14-190H CASK Studsvik Processing Facility Erwin, TN 09/24/02 R & R Trucking (Flatbed) US Ecology Oak Ridge, TN 12/09/02 R & R Trucking (Sealand) RACE LLC Memphis, TN 12/16/02 R & R Trucking (Sealand) RACE LLC Memphis, TN 12/18/02 R & R Trucking (Sealand) RACE LLC Memphis, TN B. Irradiated Fuel Shipments No irradiated fuel shipments were made from the Kewaunee Nuclear Power Plant during 2002.
Page 60 of 61
7.0 PROGRAM REVISIONS In accordance with Technical Specifications 6.18.b.3 and 6.19.a, the revisions to the Process Control Program, Offsite Dose Calculation Manual and radioactive waste treatment systems are listed below.
7.1 Offsite Dose Calculation Manual The Offsite Dose Calculation Manual (ODCM) has not been revised during this report period.
7.2 Major Changes to the Radioactive Liquid, Gaseous and Solid Waste Treatment Systems Major changes to the radioactive liquid, gaseous or solid waste systems are submitted in the annual Updated Final Safety Analysis Report consistent with Technical Specification 6.19.
8.0 REPORTABLE OCCURRENCES Approximately 911 gallons of Component Cooling Water was released through a leak in "A" Component Cooling Water Heat Exchanger and discharged to Lake Michigan from May 1, 2002 through May 3, 2002. A miscellaneous discharge permit was generated to capture this event.
This occurrence is being reported per Activity Request #CA007753.
Page 61 of 6l
Appendix A Kewaunee Nuclear Power Plant 2002 Meteorological Data Missing Data First Quarter: 3.00 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> Second Quarter: 44.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> Third Quarter: 130.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> Fourth Quarter: 117.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br /> Note: A total of 295.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> of data is missing or otherwise unavailable. This represents the availability of 96.6% of the data for the year. Continuous strip chart indication for 2002 data is available onsite.
APPENDIX A Annual Radioactive Effluent Release Report 2002 FIRST QUARTER 2002 Total Hours Missing = 3.00 Total Hours = 2160 Stabitity Class A Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 4.25 16.5 4.5 0.5 0 25.75 NNE 0 0 1.75 14.75 8.25 1 1 26.75 NE 0 0.25 6.75 28.75 9 0.75 0 45.5 ENE 0 0 4 11 10 3.5 1.25 29.75 E 0 0 8.75 7.5 4.5 1 0 21.75 ESE 0 0 7 8.75 9.5 0.75 0 26 SE 0 0 10.5 8 10.25 0.25 0 29 SSE 0 1.75 7.5 20.25 14.75 4.5 0 48.75 S 0 1 3.25 11.5 16.25 3.5 0.25 35.75 SSW 0 0 4 6 6.25 0 0 16.25 SW 0 0 2.25 3.5 1.5 0 0 7.25 WSW 0 0 2.5 4.75 5.25 3.75 0 16.25 W 0 0 1.75 3.25 5.5 3.75 1.5 15.75 WNW 0 0 3.25 5 7 4.75 0.75 20.75 NW 0 0 5.5 17.25 7.25 3 0.75 33.75 NNW 0 0 6.25 29.75 3.5 1.5 0 41 TOTAL 0 3 79.25 196.5 123.25 32.5 5.5 440 Stabitity Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.75 4 0.25 0 0 5 NNE 0 0 0 1 0 0.5 1 2.5 NE 0 0 0.75 2 0.75 0.75 0 4.25 ENE 0 0 0.75 1.5 0.75 0.5 0.75 4.25 E 0 0.25 0.25 1.25 0.25 0 0 2 ESE 0 0 0.5 1.25 1.25 0 0 3 SE 0 0 2 6 1.75 0 0 9.75 SSE 0 0 0.5 2.5 1.75 0 0 4.75 S 0 0 1.25 2.75 1.75 0.75 0 6.5 SSW 0 0 2 3.75 1.75 0.5 0 8 SW 0 0.25 0.75 1 0.25 0 0 2.25 WSW 0 0 0 0.5 0.25 0 0 0.75 W 0 0 0 0.75 1.5 1 0.25 3.5 WNW 0 0 0.5 0.75 0.75 0 0 2 NW 0 0 0 2.75 0 0 0 2.75 NNW 0 0.25 1.75 6 2.5 0 0 10.5 TOTAL 0 0.75 11.75 37.75 15.5 4 2 71.75 Page A2 of Al 5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.5 3 0.5 0 0 4 NNE 0 0 0.25 1.75 2.5 2 0.75 7.25 NE 0 0.25 1.25 2.5 0.25 0.25 0 4.5 ENE 0 0 1 4.75 0.25 0 0.75 6.75 E 0 0 0.75 1 0.25 0 0.25 2.25 ESE 0 0 0.75 2.5 1.5 0 0 4.75 SE 0 0 0.5 4.25 1.25 0.25 0 6.25 SSE 0 0 1 2.75 1.5 0 0.25 5.5 S 0 0 0.5 1.75 2.25 1 0 5.5 SSW 0 0 2.25 4.5 1 0 0 7.75 SW 0 0 1 0.75 0.25 0 0 2 WSW 0 0 0.25 0.75 0.25 0 0 1.25 W 0 0 0.5 1 3.25 3.25 0.75 8.75 WNW 0 0 1 0.75 5.75 0.5 0 8 NW 0 0 0.5 3.25 0.5 0 0 4.25 NNW 0 0.5 2.25 4.75 2.5 1.75 0 11.75 TOTAL 0 0.75 14.25 40 23.75 9 2.75 90.5 Stabitity Class D Wind Directi on C' KLM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.25 8 12.5 7.75 0.25 0 28.75 NNE 0 0.75 3 14.75 13 3.75 0.5 35.75 NE 0 1.5 6.75 12.25 2.25 0.25 0 23 ENE 0 0 4.5 10.25 4 0.5 0 19.25 E 0 0 4.25 11 4.5 1.75 0.75 22.25 ESE 0 0.75 5.5 9.5 7.5 0.75 0 24 SE 0 0 5.25 5.5 5.5 0.25 0 16.5 SSE 0 0.25 4.5 9.25 8.5 0.25 0 22.75 S 0 0.5 2.25 7.25 9 1 0.25 20.25 SSW 0 0 13.75 9.5 1.75 0 0 25 SW 0 0.25 1.5 1.25 0.5 0 0 3.5 WSW 0 0.25 1.5 2.5 3.5 0.5 0 8.25 W 0 0.25 3.75 9.75 8.25 4.25 1 27.25 WNW 0 0.25 5.25 6.75 2.5 1.75 0 16.5 NW 0 0.5 3.75 4 1 0 0 9.25 NNW 0 2.5 12.5 24.75 4.25 0 0 44 TOTAL 0 8 86 150.75 83.75 15.25 2.5 346.25 Page A3 of Al 5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class E Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 2.25 0.75 7.75 14.25 4.25 0 0 29.25 NNE 0 1 5.25 7 9.5 3.75 0.75 27.25 NE 0 1 8.5 5.5 0 0.25 0 15.25 ENE 0 1.75 6.75 1.75 0.25 0 0 10.5 E 0 1.25 10.5 3.25 1.25 0 0 16.25 ESE 0 1.5 11 8.75 4.25 0.5 0 26 SE 0 3.25 13 2.25 0.25 0 0 18.75 SSE 0 6 21 4.25 4.75 4 0 40 S 0 3.25 11.75 9.75 4.5 0.75 0 30 SSW 0 2 16 9.25 1.5 0 0 28.75 SW 0 1.25 7.75 4.25 1 0 0 14.25 WSW 0 1.5 5 6.75 2 2.25 0.25 17.75 W 0 0.75 6.75 12.75 3 6 1.75 31 WNW 0.25 1.5 11 17.75 4.5 0 0 35 NW 0 0.5 5.5 1.25 2 0 0 9.25 NNW 0 8.5 18.75 8.5 1.25 0 0 37 TOTAL 2.5 35.75 166.25 117.25 44.25 17.5 2.75 386.25 Stabitity Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 1.5 6.5 5.75 0.25 0 0 14 NNE 0.5 1.5 3.5 2.5 0.25 0.75 0 9 NE 0 1 5.25 1.5 0 0 0 7.75 ENE 0 0.75 4 0.25 0 0 0 5 E 0 1.25 4.5 0.25 0 0 0 6 ESE 0 2.5 6.5 3 1.25 0.25 0.25 13.75 SE 0 1.75 11.5 2.25 0.25 0 0 15.75 SSE 0 5.5 12.5 5.5 8.25 0.75 0 32.5 S 0 2.5 8.5 6.75 4 0 0 21.75 SSW 0 3 19 11.5 0.5 0 0 34 SW 0 1 8.75 4.75 1.75 0 0.25 16.5 WSW 0 2.5 5.5 2.25 4 0.5 0 14.75 W 0 1.75 10 4 0.75 0.25 0 16.75 WNW 0 2 14.75 10 0.25 0 0 27 NW 0 1.25 6 4.25 0.75 0 0 12.25 NNW 0 8.25 32.5 6.25 1.75 0 0 48.75 TOTAL 0.5 38 159.25 70.75 24 2.5 0.5 295.5 Page A4 of Al5
L APPENDIX A Annual Radioactive Effluent Release Report 2002 L Stabitity Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 6.5 9.5 9 0.25 0 0 25.25 U NNE NE 0
0 3.5 3
7.25 2.25 4
0.5 0
0 0
0 0
0 14.75 5.75 ENE 0 2.25 2.75 0.25 0 0 0 5.25 L E ESE 0
0 4.75 3.5 3.75 6.25 0.5 1.75 0
0.5 0
0 0
0 9
12 SE 0 5 18 4.75 0 0 0 27.75 0.25 14.25 24 7.75 1.5 1 0 48.75 SSE S 0 2.75 20.5 12.25 2.25 0.25 0 38 0 3.5 15 2 0 0 0 20.5 SSW 0 4.25 26.25 16.75 0.25 0 0 47.5 SW WSW 0 4 36.75 27.25 0.75 0 0 68.75 0 4.25 43.25 16.25 1.75 0.25 0 65.75 W
0 4 19 4 0.25 0.25 0.25 27.75 WNW NW 0 3.25 12.5 1.75 0.5 0.25 0 18.25 L NNW TOTAL 0
0.25 11.5 80.25 42 289 19.25 128 0.5 8.5 0.75 2.75 0
0.25 74 509 L 2nd QUARTER 2002 Total Hours Missing = 44.75 Total Hours = 2184 Stabitity Class A L
Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL L N 0 0 4.25 16.5 4.5 0.5 0 25.75 NNE 0 0 1.75 14.75 8.25 1 1 26.75 0 0.25 6.75 28.75 9 0.75 0 45.5 NE 0 0 4 11 10 3.5 1.25 29.75 ENE E 0 0 8.75 7.5 4.5 1 0 21.75 L ESE SE 0
0 0
0 7
10.5 8.75 8
9.5 10.25 0.75 0.25 0
0 26 29 SSE 0 1.75 7.5 20.25 14.75 4.5 0 48.75 L S SSW 0
0 1
0 3.25 4
11.5 6
16.25 6.25 3.5 0
0.25 0
35.75 16.25 SW 0 0 2.25 3.5 1.5 0 0 7.25 L WSW W
0 0
0 0
2.5 1.75 4.75 3.25 5.25 5.5 3.75 3.75 0
1.5 16.25 15.75 WNW 0 0 3.25 5 7 4.75 0.75 20.75 NW 0 0 5.5 17.25 7.25 3 0.75 33.75 NNW 0 0 6.25 29.75 3.5 1.5 0 41 0 3 79.25 196.5 123.25 32.5 5.5 440 TOTAL Page AS of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.75 4 0.25 0 0 5 NNE 0 0 0 1 0 0.5 1 2.5 NE 0 0 0.75 2 0.75 0.75 0 4.25 ENE 0 0 0.75 1.5 0.75 0.5 0.75 4.25 E 0 0.25 0.25 1.25 0.25 0 0 2 ESE 0 0 0.5 1.25 1.25 0 0 3 SE 0 0 2 6 1.75 0 0 9.75 SSE 0 0 0.5 2.5 1.75 0 0 4.75 S 0 0 1.25 2.75 1.75 0.75 0 6.5 SSW 0 0 2 3.75 1.75 0.5 0 8 SW 0 0.25 0.75 1 0.25 0 0 2.25 WSW 0 0 0 0.5 0.25 0 0 0.75 W 0 0 0 0.75 1.5 1 0.25 3.5 WNW 0 0 0.5 0.75 0.75 0 0 2 NW 0 0 0 2.75 0 0 0 2.75 NNW 0 0.25 1.75 6 2.5 0 0 10.5 TOTAL 0 0.75 11.75 37.75 15.5 4 2 71.75 Stabitity Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.5 3 0.5 0 0 4 NNE 0 0 0.25 1.75 2.5 2 0.75 7.25 NE 0 0.25 1.25 2.5 0.25 0.25 0 4.5 ENE 0 0 1 4.75 0.25 0 0.75 6.75 E 0 0 0.75 1 0.25 0 0.25 2.25 ESE 0 0 0.75 2.5 1.5 0 0 4.75 SE 0 0 0.5 4.25 1.25 0.25 0 6.25 SSE 0 0 1 2.75 1.5 0 0.25 5.5 S 0 0 0.5 1.75 2.25 1 0 5.5 SSW 0 0 2.25 4.5 1 0 0 7.75 SW 0 0 1 0.75 0.25 0 0 2 WSW 0 0 0.25 0.75 0.25 0 0 1.25 W 0 0 0.5 1 3.25 3.25 0.75 8.75 WNW 0 0 1 0.75 5.75 0.5 0 8 NW 0 0 0.5 3.25 0.5 0 0 4.25 NNW 0 0.5 2.25 4.75 2.5 1.75 0 11.75 TOTAL 0 0.75 14.25 40 23.75 9 2.75 90.5 Page A6 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class D Wind Direction 1-3 4-7 8-12 13-18 19-24 >24 TOTAL CALM 0.25 8 12.5 7.75 0.25 0 28.75 N 0 0 0.75 3 14.75 13 3.75 0.5 35.75 NNE 1.5 6.75 12.25 2.25 0.25 0 23 NE 0 0 0 4.5 10.25 4 0.5 0 19.25 ENE 0 0 4.25 11 4.5 1.75 0.75 22.25 E
0.75 5.5 9.5 7.5 0.75 0 24 ESE 0 0 5.25 5.5 5.5 0.25 0 16.5 SE 0 0.25 4.5 9.25 8.5 0.25 0 22.75 SSE 0 0 0.5 2.25 7.25 9 1 0.25 20.25 S
0 13.75 9.5 1.75 0 0 25 SSW 0 0.25 1.5 1.25 0.5 0 0 3.5 SW 0 0 0.25 1.5 2.5 3.5 0.5 0 8.25 WSW 0 0.25 3.75 9.75 8.25 4.25 1 27.25 W
0.25 5.25 6.75 2.5 1.75 0 16.5 WNW 0 0 0.5 3.75 4 1 0 0 9.25 NW 2.5 12.5 24.75 4.25 0 0 44 NNW 0 8 86 150.75 83.75 15.25 2.5 346.25 TOTAL 0 Stabitity Class E Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 2.25 0.75 7.75 14.25 4.25 0 0 29.25 N
0 1 5.25 7 9.5 3.75 0.75 27.25 NNE 0 1 8.5 5.5 0 0.25 0 15.25 NE 0 1.75 6.75 1.75 0.25 0 0 10.5 ENE 0 1.25 10.5 3.25 1.25 0 0 16.25 E
1.5 11 8.75 4.25 0.5 0 26 ESE 0 3.25 13 2.25 0.25 0 0 18.75 SE 0 0 6 21 4.25 4.75 4 0 40 SSE 0 3.25 11.75 9.75 4.5 0.75 0 30 S
0 2 16 9.25 1.5 0 0 28.75 SSW 0 1.25 7.75 4.25 1 0 0 14.25 SW 0 1.5 5 6.75 2 2.25 0.25 17.75 WSW 0 0.75 6.75 12.75 3 6 1.75 31 W
1.5 11 17.75 4.5 0 0 35 WNW 0.25 0 0.5 5.5 1.25 2 0 0 9.25 NW 0 8.5 18.75 8.5 1.25 0 0 37 NNW 2.5 35.75 166.25 117.25 44.25 17.5 2.75 386.25 TOTAL Page A7 of Al 5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class F Wind Direction 1-3 4-7 8-12 13-18 19-24 >24 TOTAL CALM 1.5 6.5 5.75 0.25 0 0 14 N 0 QE5 1.5 3.5 2.5 0.25 0.75 0 9 NNE 0 1 5.25 1.5 0 0 0 7.75 NE 0 0.75 4 0.25 0 0 0 5 ENE 0 1.25 4.5 0.25 0 0 0 6 E
0 2.5 6.5 3 1.25 0.25 0.25 13.75 ESE 0 1.75 11.5 2.25 0.25 0 0 15.75 SE 0 5.5 12.5 5.5 8.25 0.75 0 32.5 SSE 0 2.5 8.5 6.75 4 0 0 21.75 S
0 3 19 11.5 0.5 0 0 34 SSW 0 1 8.75 4.75 1.75 0 0.25 16.5 SW 0 2.5 5.5 2.25 4 0.5 0 14.75 WSW 0 1.75 10 4 0.75 0.25 0 16.75 W
0 2 14.75 10 0.25 0 0 27 WNW 0 1.25 6 4.25 0.75 0 0 12.25 NW 0 8.25 32.5 6.25 1.75 0 0 48.75 NNW 159.25 70.75 24 2.5 0.5 295.5 TOTAL 0.5 38 Stabitity Class G Wind Direc tion
,ALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 0 6.5 9.5 9 0.25 0 0 25.25 N
NNE 0 3.5 7.25 4 0 0 0 14.75 NE 0 3 2.25 0.5 0 0 0 5.75 ENE 0 2.25 2.75 0.25 0 0 0 5.25 E 0 4.75 3.75 0.5 0 0 0 9 0 3.5 6.25 1.75 0.5 0 0 12 ESE 0 5 18 4.75 0 0 0 27.75 SE 0.25 14.25 24 7.75 1.5 1 0 48.75 SSE 0 2.75 20.5 12.25 2.25 0.25 0 38 S
0 3.5 15 2 0 0 0 20.5 SSW SW 0 4.25 26.25 16.75 0.25 0 0 47.5 WSW 0 4 36.75 27.25 0.75 0 0 68.75 W 0 4.25 43.25 16.25 1.75 0.25 0 65.75 0 4 19 4 0.25 0.25 0.25 27.75 WNW 0 3.25 12.5 1.75 0.5 0.25 0 18.25 NW 0 11.5 42 19.25 0.5 0.75 0 74 NNW 0.25 80.25 289 128 8.5 2.75 0.25 509 TOTAL Page A8 of A15
APPENDIX A Annual Radioactive Effluent Release Report 2002 3r' QUARTER 2002 Total Hours Missing = 130.75 Total Hours = 2208 Stabitity Class A Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 6 5 0 0 0 11 NNE 0 0 0.25 7 0.5 0 0 7.75 NE 0 0 0.25 0 0 0 0 0.25 ENE 0 0.25 0.5 0 0 0 0 0.75 E 0 0 0 2.5 0.5 0 0 3 ESE 0 0 2.75 2.5 0 0 0 5.25 SE 0 0.5 5.5 3.5 0 0 0 9.5 0 0.5 21.75 20.25 8.5 2 0 53 SSE S 0 0 8.25 0.5 0 0 0 8.75 SSW 0 0 5.75 0.75 0 0 0 6.5 SW 0 0 3 1 0.25 0.25 0 4.5 WSW 0 0 0.5 1.25 0 0 0 1.75 W 0 0 0.25 1.5 0 0 0 1.75 WNW 0 0 2.5 8.25 0.25 0 0 11 NW 0 0 4 10 1 0 0 15 NNW 0 1.25 47.25 51.5 16.75 0 0 116.75 TOTAL 0 2.5 108.5 115.5 27.75 2.25 0 256.5 Stabitity Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 1 2.75 0.25 0 0 4 NNE 0 0 1 3.5 1.5 0 0 6 NE 0 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 0 E 0 0 0.5 0.75 0 0 0 1.25 ESE 0 0 0.5 0 0 0 0 0.5 SE 0 0 0.5 0 0 0 0 0.5 0 0 1.75 3.25 0.5 0.5 0 6 SSE S 0 0 0.25 0.25 0 0 0 0.5 SSW 0 0 0.5 0 0 0 0 0.5 SW 0 0 0.5 0.25 0 0 0 0.75 WSW 0 0 0.25 0.25 0.5 0 0 1 W 0 0 0 0.25 0 0 0 0.25 WNW 0 0 0.75 0.5 0 0 0 1.25 NW 0 0 0.5 1.25 0.25 0 0 2 NNW 0 0.25 7.25 13.5 2 0.5 0 23.5 TOTAL 0 0.25 15.25 26.5 5 1 0 48 Page A9 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 0.5 4.75 0 0 0 5.25 NNE 0 0 1 0.5 1 0.25 0 2.75 NE 0 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 0 E 0 0 1 1 0.5 0 0 2.5 ESE 0 0 0 0 0 0 0 0 SE 0 0 2.25 0 0 0 0 2.25 SSE 0 0.5 4.75 2.5 0.5 0.75 0 9 S 0 0 1 1 0.5 0 0 2.5 SSW 0 0 2.25 0.25 0 0 0 2.5 SW 0 0 1 0 0 0 0 1 WSW 0 0 0.5 0.25 0.25 0 0 1 W 0 0 1 0 0 0 0 1 WNW 0 0 0.25 1.25 0 0 0 1.5 NW 0 0 0.5 1.25 1 0 0 2.75 NNW 0 0.25 8 7 2 0 0 17.25 TOTAL 0 0.75 24 19.75 5.75 1 0 51.25 Stabitity Class D Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 3.75 13 0.75 0 0 17.5 NNE 0 0.25 2 7.5 4 0.25 0 14 NE 0 0 1 0.5 0 0 0 1.5 ENE 0 0.25 2 0 0.25 0 0 2.5 E 0 0.25 1.25 4.75 3.75 0 0 10 ESE 0 0.25 1 3 0 0 0 4.25 SE 0 0.75 2.25 0 0 0 0 3 SSE 0 1 22.5 14.5 4.5 1 0 43.5 S 0 0 2 4.25 1 0 0 7.25 SSW 0 0 2.75 2.5 0.5 0 0 5.75 SW 0 0 2.5 1.25 0 0 0 3.75 WSW 0 0 0.25 2.5 1.5 0 0 4.25 W 0 0 0.5 1.75 0 0 0 2.25 WNW 0 0 0.75 2.25 0.25 0 0 3.25 NW 0 0 1.5 5.75 2 0 0 9.25 NNW 0 2.5 32.75 34.5 4.75 0.5 0 75 TOTAL 0 5.25 78.75 98 23.25 1.75 0 207 Page A10 of A15
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class E Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 0 10 6.25 0.25 0 0 16.5 N 0 0 4.25 11.25 4.5 0 0 20 NNE 0 0 0 9 1.5 0 0 0 10.5 NE 0 0 4.75 4 0 0 0 8.75 ENE 0 0.5 7.75 5.75 3.75 0 0 17.75 E
0.5 4 11.25 0.5 0 0 16.25 ESE 0 0.5 3.75 0 0 0 0 4.25 SE 0 9.5 63.25 35 6.5 0 0 114.25 SSE 0 0.25 2.75 3.25 2.5 0 0 8.75 S 0 0 0.25 6.5 1.5 0 0 0 8.25 SSW 0 0 4 1.5 0 0 0 5.5 SW 0 0.25 4 5.5 0 0 0 9.75 WSW 0 0 2.5 4.75 0.25 0 0 7.5 W
0 0 1.75 2.75 0.25 0 0 4.75 WNW 0 0 2.25 4.5 0.75 0 0 7.5 NW 0 5.5 78.75 53.5 7.5 1.25 0 146.5 NNW 0 17.25 209.25 152.25 26.75 1.25 0 406.75 TOTAL Stabitity Class F Wind Directiion 4-7 8-12 13-18 19-24 >24 TOTAL C)ALM 1-3 0 1 3.5 2.5 0 0 0 7 N
0 1 4 1.75 0 0 0 6.75 NNE 0 0.5 3 1 0 0 0 4.5 NE 0.25 2.5 3 0 0 0 5.75 ENE 0 0 2 1.5 0.25 0 0 0 3.75 E
2.25 2.5 2.5 0 0 0 7.25 ESE 0 1.25 2.5 0 0 0 0 3.75 SE 0 8.5 46 24.25 6 0 0 84.75 SSE 0 0 1.5 8.25 3.5 0.75 0 0 14 S
0 2.5 10.5 2.25 0.5 0 0 15.75 SSW 0 0.5 8.25 2 0 0 0 10.75 SW 0 0.75 9.75 3 0.75 0 0 14.25 WSW 1 8.75 4.75 0 0 0 14.5 W 0 WNW 0.25 2.25 1 0 0 0 3.5 0
0 0.25 6.75 8.25 0 0 0 15.25 NW 0 10.75 70 25 1.5 0 0.25 107.5 NNW 0 34.25 190 85 9.5 0 0.25 319 TOTAL Page All of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 0 3.25 16.5 7 0 0 0 26.75 N
0 6 5.5 0 0 0 0 11.5 NNE 0 5.25 7.75 0.25 0 0 0 13.25 NE 0 4.25 3.75 0 0 0 0 8 ENE 0 3.5 2 0 0 0 0 5.5 E
0 2.25 1.75 0.75 0 0 0 4.75 ESE 0 1.25 9.5 7 0 0 0 17.75 SE 0 17 92.25 36.25 3.5 0.5 0 149.5 SSE 0 7 19.25 3.25 0 0 0 29.5 S
0 9.25 13.5 2.75 0.25 0 0 25.75 SSW 0 7.5 26 15 0.5 0 0 49 SW 0 2.5 21.75 7 0.75 0 0 32 WSW 0 3.75 12.75 7 0.75 0 0 24.25 W
0 4.5 17.75 0.5 0 0 0 22.75 WNW 0 3 27.5 6.5 0 0 0 37 NW 0 61 220.5 47.75 2.25 0 0 331.5 NNW 0 141.25 498 141 8 0.5 0 788.75 TOTAL 4th QUARTER 2002 Total Hours Missing 117.25 Total Hours = 2208 Stabitity Class A Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 0 0 5.5 21 7.75 1 0 35.25 N
0 0 3 9 2 0 0 14 NNE 0 0 2.25 4.75 0.75 0 0 7.75 NE 0 0 4.75 12.75 5 0 0 22.5 ENE 0 0 5 14.5 3.25 0 0 22.75 E
0 0 3.75 6.25 8 8.5 0.5 27 ESE 0 0.25 3.25 2.75 17.5 3.75 0.5 28 SE 0 0 1.5 1.25 4.5 0 0.75 8 SSE S 0 0 2.5 4.75 7.5 1.5 0.5 16.75 0 0 1.75 10.25 2 0.25 0 14.25 SSW 0 0.25 5.25 17.25 10.25 1 0 34 SW 0 0 5.75 20.75 20.25 1 0 47.75 WSW W 0 0 7 22 24 10.75 1 64.75 0 0 10.25 34.25 19 1.75 0 65.25 WNW 0 0 13 19.5 4.5 1 0 38 NW 0 0 10.5 26 4.25 0.75 0 41.5 NNW 0 0.5 85 227 140.5 31.25 3.25 487.5 TOTAL Page A12 of AI5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0 1.75 7.5 4.5 0.25 0 14 NNE 0 0 1 0 0.5 0 0 1.5 NE 0 0 0.25 0.25 1 0 0 1.5 ENE 0 0 0.5 0.5 1 0 0 2 E 0 0 0.5 2.5 1.5 0 0 4.5 ESE 0 0 1.25 0.75^ 0 0 0 2 SE 0 0 1 0.25 1.75 1 0 4 SSE 0 0 0 1.25 0.75 0.75 0 2.75 S 0 0 0.25 0.5 1.5 1 0 3.25 SSW 0 0 0.5 2.25 0.25 0 0 3 SW 0 0 0.25 1.75 2.25 0 0 4.25 WSW 0 0 1 2.75 3.5 0 0 7.25 W 0 0 0 4.25 3.5 2.25 0 10 WNW 0 0 2.25 8 1.75 0.25 0 12.25 NW 0 0 3.75 4 0.25 0.25 0 8.25 NNW 0 0 2.75 7.75 5 0.25 0 15.75 TOTAL 0 0 17 44.25 29 6 0 96.25 Stabitity Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.25 2.25 7.75 2.25 0 0 12.5 NNE 0 0.25 0.5 1 0.25 0 0 2 NE 0 0 0.25 0.75 0 0 0 1 ENE 0 0 0.75 0.5 0 0 0 1.25 E 0 0 0 0 0 0 0 0 ESE 0 0 1.5 0.25 0 0 0 1.75 SE 0 0 1 1.25 1.75 1 0.25 5.25 SSE 0 0 0.25 0.25 1 1.75 0 3.25 S 0 0 0 0.5 0.75 0.75 0 2 SSW 0 0 0.75 3.25 0.25 0 0 4.25 SW 0 0 0.75 1 1.5 0 0 3.25 WSW 0 0.25 0.5 4.25 2 0 0 7 W 0 0.25 0.5 3.5 9.5 7.75 0.5 22 WNW 0 0 2 7.75 4.5 0.5 0 14.75 NW 0 0.25 1.25 3.5 0.5 0 0 5.5 NNW 0 0 2.25 4.25 5.25 0.75 0.25 12.75 TOTAL 0 1.25 14.5 39.75 29.5 12.5 1 98.5 Page A13 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class D Wind Directi on C)KLM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 16.5 25.5 7.25 0 0 49.25 N o 0 3.75 7.5 3.25 0 0 14.5 NNE O 0 1.5 3.75 0.25 0 0 5.5 NE o 0 ENE 0 0 4.25 1 0.25 0 0 5.5 0 1.25 4.5 0.25 0 0 6 E 0 0 0.5 1.25 0.5 0.25 0 0 2.5 ESE 0 0 2.75 8.25 6.75 4 0 21.75 SE o 0 0.75 2.75 3.5 11.5 2.5 21 SSE 0 0 2 10.5 4.5 1.25 0.25 18.5 S
0 7 20 1 0 0 28 SSW 0 0 0 3.75 12.5 4 0.25 0 20.5 SW 0.25 7 13.75 5.25 0 0 26.25 WSW 0 0 1.25 10.5 28.75 37.75 4.5 0 82.75 W
0 0.5 11.75 33.75 5.75 0 0 51.75 WNW 0 0.25 8 12 6 0.5 0 26.75 NW 0 0.5 21.75 23 7.5 1.25 0 54 NNW 0 3.25 103.75 208 93.5 23.25 2.75 434.5 TOTAL Stabitity Class E Wind Directi on C.,KLM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL 12.25 15.75 2.75 0 0 31.75 N 0 1 4.75 3 0 0 9.25 NNE 0 0.5 I 0.5 I 0.75 0 0 2.25 NE 0 0 0.25 0 0 0 1 ENE 0 0.25 0.5 3 0 0 0 4.25 E 0 0 1.25 1.25 1 0.25 0.5 0 3.25 ESE 0 0.25 7.25 4.5 2.75 0.25 18.75 SE 0 1 3 7.5 4.5 5.5 2.75 25 SSE 0 1.5 3.25 10 9.75 3 0 32.75 S 0 0.5 9.5 11.5 1.75 0 0 43 SSW 0 0.5 29.25 15.75 11.75 2 0 50.25 SW 0 1.75 19 23 10.25 3 0 47.25 WSW 0 1 10 14.5 37.75 16.5 3.5 0 76 W 0 3.75 33.25 7.25 0.75 0 63 WNW 0 8 13.75 7.75 I 0 0 28.25 NW 0 5.75 13.75 20.5 0.75 0 0 48.5 NNW 0 4 23.25 200 74.75 21 3 484.5 TOTAL 0 29.75 156 Page A14 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2002 Stabitity Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 0.75 2.5 1.5 0 0 0 4.75 NNE 0 0.5 0.25 0.5 0.25 0 0 1.5 NE 0 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 0 E 0 0.5 0.25 0.25 0 0 0 1 ESE 0 0.25 0 0 0 0 0 0.25 SE 0 0.75 1 0 0.5 0 0 2.25 SSE 0 2.5 7.25 3.5 1.25 0.25 0 14.75 S 0 2.75 11 2 0.25 0 0 16 SSW 0 1.25 14.25 5.5 0.75 0 0 21.75 SW 0 0.25 22 8.25 8.25 1 0 39.75 WSW 0 1.75 7.75 7.5 6 0.25 0 23.25 W 0 4 20.5 6.75 0.75 0 0 32 WNW 0 1.25 21.5 11 0 0 0 33.75 NW 0 1 14.5 4.25 0 0 0 19.75 NNW 0 2.5 7.75 10.75 0 0 0 21 TOTAL 0 20 130.5 61.75 18 1.5 0 231.75 Stabitity Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 0 1.5 4 0 0 0 0 5.5 NNE 0 0.25 0 0.25 0 0 0 0.5 NE 0 0.5 0 0 0 0 0 0.5 ENE 0 0.25 0.25 0 0 0 0 0.5 E 0 0.25 0 0 0 0 0 0.25 ESE 0 0.25 0 0 0 0 0 0.25 SE 0 0.25 1.25 0.25 0 0 0 1.75 SSE 0 2.25 5 3.5 0 0 0 10.75 S 0 1.5 6.75 0.25 0 0 0 8.5 SSW 0 1.25 16.75 1.25 0 0 0 19.25 SW 0 4 13 3.75 0 0.25 0 21 WSW 0 8 32.5 13.5 0 0 0 54 W 0 5 61.5 4 0 0 0 70.5 WNW 0 5 31.25 4.25 0 0 0 40.5 NW 0 3.25 9.75 1 0 0 0 14 NNW 0 2.25 4.75 3 0 0 0 10 TOTAL 0 35.75 186.75 35 0 0.25 0 257.75 Page A]5 of Al5