Submittal of 2016 Annual Radiological Environmental Operating Report
ML17138A298
Person / Time
Site: Kewaunee 
Issue date: 05/10/2017
From: Yuen S
Dominion Energy Kewaunee
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
17-192
Download: ML17138A298 (159)


Text

Dominion Energy Kewaunee, Inc.

N490 Highway 42, Kewaunee, WI 54216-9511 MAY 1, 0 2017 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 DOMINION ENERGY KEWAUNEE. INC.

KEWAUNEE POWER STATION Serial No.17-192 UC/RR/RO Docket No.:

50-305 License No.: DPR-43 2016 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT Enclosed is the 2016 Annual Radiological Environmental Operating Report for the Kewaunee Power Station (KPS). This report was prepared by ATI Environmental Inc.

and satisfies the requirements of KPS Technical Specification 5.6.1.

The results of the 2016 Land Use Census, submitted in accordance with the KPS Radiological Environmental Monitoring Manual, Section 2.2.2/2.3.2, are also included in th is report.

Please feel free to contact Mr. Richard Repshas at 920-388-8217 if you have questions or require additional information.

Sincerely, Stewart J. Yuen Plant Manager, Kewaunee Power Station Commitments made by this letter: NONE

cc:

Regional Administrator, Region Ill U. S. Nuclear Regulatory Commission 2443 Warrenville Road Suite 210 Lisle, IL 60532-4352 Mr. Ted H. Carter NRC Senior Project Manager U.S. Nuclear Regulatory Commission Two White Flint North, Mail Stop T-8F5 11555 Rockville Pike Rockville, MD 20852-2738 Mr. Robert Busch Wisconsin Division of Public Health Radiation Protection Section Room 150 Madison, WI 53701-2659 Ms. Deborah Russo

  • American Nuclear Insurers 95 Glastonbury Blvd.

Glastonbury, CT 06033 Serial No.17-192 Page 2 of 2

I 2016 Annual Radiological EnvironIDental Operating Report Kewaunee Power Station Dominion Energy Kewaunee, Inc.

2016 Annual Radiological Environillental Operating Report Kewaunee Power Station Part!

Summary and Interpretation Dominion Energy Kewaunee, Inc.

~

~

~

f *

~~!J.> ATI Environmental, Inc.

V'~\\!}. /"\\.D Midwest Laboratory 700 Landwehr Road

  • Northbrook. IL 60062-2310 phone (847) 5 64..0700
  • fax (847) 564-45 17 Approved:

ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERA TING REPORT TO DOMINION NUCLEAR RADIOLOGICAL MONITORING PROGRAM FOR THE KEWAUNEE POWER STATION KEWAUNEE, WISCONSIN PART 1-

SUMMARY

AND INTERPRETATION January 1 to December 31, 2016 Prepared and submitted by:

ATI ENVIRONMENTAL Inc.

Midwest Laboratory Project No. 8002 J. Michael Hale Radiation Protection I Chemistry Mgr., KPS

PREFACE The staff of ATI Environmental, Inc., Midwest Laboratory were responsible for the acquisition of data presented in this report. Assistance in sample collection was provided by Kewaunee Power Station personnel. The report was prepared by staff members of ATI Environmental, Inc., Midwest Laboratory.

ii

This Page Intentionally Left Blank

TABLE OF CONTENTS Preface......................................................................................................................................................... ii List of Figures.......................................................................................,...................................................... iv List of Tables............................................................................................................................................... iv

1.0 INTRODUCTION

......................................................................................................................................... 1 2.0

SUMMARY

................................................................................................................................................... 2 3.0 RADIOLOGICAL SURVEILLANCE PROGRAM.......................................................................................... 3 3.1 Methodology.................................................................................................................................. 3 3.1.1 The Air Program.............................................................................................................. 3 3.1.2 The Terrestrial Program.................................................................................................. 4 3.1.3 The Aquatic Program...................................................................................................... 5 3.1.4 Program Execution.......................................................................................................... 6 3.1.5 Program Modifications.................................................................................................... 6 3.2 Results and Discussion................................................................................................................. 7 3.2.1 Atmospheric Nuclear Detonations and Nuclear Accidents.............................................. 7 3.2.2 The Air Environment....................................................................................................... 7 3.2.3 The Terrestrial Environment.......................................................................................... 10 3.2.4 The Aquatic Environment.............................................................................................. 12 3.3 Land Use Census........................................................................................................................ 13 3.4 Laboratory Procedures................................................................................................................ 14 4.0 FIGURES AND TABLES............................................................................................................................ 15

5.0 REFERENCES

.......................................................................................................................................... 28 APPENDICES A

lnterlaboratory Comparison Program Results............................................................................ A-1 B

Data Reporting Conventions...................................................................................................... 8-1 C

Effluent Concentrations............................................................................................................. C-1 iii

LIST OF FIGURES 4-1 Sampling. locations, Kewaunee Power Station............................................................................ 16 4-2 Groundwater Monitoring Wells, Kewaunee Power Station........................................................... 17 LIST OF TABLES 4.1 Sampling locations, Kewaunee Power Station............................................................................ 18 4.2 Type and frequency of collection................................................................................................ 19 4.3 Sample codes used in Table 4.2................................................................................................ 19 4.4 Sampling summary, January - December, 2016........................................................................ 20 4.5 Environmental Radiological Monitoring Program Summary....................................................... 21 4.6 Land Use Census....................................................................................................................... 27 In addition, the following tables are in the Appendices:

Appendix A A-1 lnterlaboratory Comparison Program Results............................................................................ A1-1 A-2 Thermoluminescent dosimeters (TLDs)..................................................................................... A2-1 A-3 In-house Spiked Samples.......................................................................................................... A3-1 A-4 A-5 A-6 A-7 In-house "Blank" Samples......................................................................................................... A4-1 In-house "Duplicate" Samples.................................................................................................... A5-1 Department of Energy MAPEP comparison results.................................................................... A6-1 Environmental Resources Associates, Crosscheck Program Results (MRAD).......................... A7-1 Attachment A: Acceptance criteria for spiked samples................................................................ A-2 iv

1.0 INTRODUCTION

The Kewaunee Power Station is a 598 megawatt pressurized water reactor located on the Wisconsin shore of Lake Michigan in Kewaunee County. The Plant became critical on March 7, 1974. Initial power generation was achieved on April 8, 1974, and the Plant was declared commercial on June 16, 1974.

On February 25, 2013, Dominion Energy Kewaunee submitted a certification of intent to cease power operations to the Nuclear Regulatory Committee. Power Operation of the Kewaunee Power Station ceased on May 7, 2013. The fuel was permanently removed from the reactor and placed in the spent fuel pool for storage on May 14, 2013.

This report summarizes the environmental operation data collected during the period January -

December 2016.

Dominion Energy Kewaunee, operator and owner of the Kewaunee Power Station, assumes responsibility for the environmental program at the Plant. Any questions should be directed to Mr. J.

Michael Hale, Radiation Protection I Chemistry Manager, at (920) 388-8103.

2.0

SUMMARY

Results of sample analyses during the period January - December 2016 are summarized in Table 4.5. Radionuclide concentrations measured at indicator locations are compared with levels measured at control locations and in preoperational studies. In no instance were REMP threshold reporting levels exceeded.

2

3.0 RADIOLOGICAL SURVEILLANCE PROGRAM Following is a description of the Radiological Surveillance Program and its execution.

3.1 METHODOLOGY The sampling locations are shown in Figure 4-1.

Table 4.1 describes the locations, lists for each direction and distance from the reactor, and defines which are indicators and control locations.

The sampling program monitors the air, terrestrial, and aquatic environments. The types of samples collected at each location and the frequency of collections are presented in Table 4.2, using sample codes defined in Table 4.3. The collections and analyses that comprise the program are described below. Finally, the execution of the program in the current reporting year is discussed.

3.1.1 The Air Program Ambient Gamma Radiation - TLDs Ambient gamma radiation is monitored at the six air sampling locations (K-1f, K-2, K-8, K-31, K-41 and K-43), at three milk sampling locations (K-3, K-5, and K-39), and from five additional sites (K-15, located 9.25 miles northwest of the plant; K-17, located 4.0 miles west of the plant; K-25, located 1.9 miles southwest of the plant; K-27, located 1.53 miles northwest of the plant and K-30, located 0.8 miles north of the plant ) by thermoluminescent dosimetry (TLD). Two TLD cards, each having four main readout areas containing CaS04:Dy phosphor, are placed at each location (eight TLDs at each location). One card is exchanged quarterly, the other card is exchanged annually and read only on an emergency basis.

Dosimeters have also been placed at eight additional locations (K-1 L through K-1 S), to monitor an Independent Spent Fuel Storage Installation (ISFSI). They are replaced and measured quarterly.

Airborne Particulates Airborne particulates are collected on 47 mm diameter, 1 µm porosity glass fiber filters, at a volumetric rate of approx. one cubic foot per minute. The filters are collected weekly from six locations (K-1f, K-2, K-8, K-31, K-41 and K-43), and dispatched by mail to ATI Environmental, Inc..

for radiometric analysis. The particulate filters are counted for gross beta activity, a minimum of three days after the date of collection, to allow for the decay of naturally-occurring short-lived radionuclides.

Quarterly composites from each sampling location are analyzed for gamma-emitting isotopes on a high-purity germanium (HPGe) detector.

Airborne Iodine Charcoal traps are located at locations K-1f, K-2, K-8, K-31, K-41 and K-43. The traps are changed weekly and analyzed for iodine-131 immediately after arrival at the laboratory.

Precipitation Monthly composites of precipitation samples are collected at K-11 and analyzed for tritium.

3

3.1.2 The Terrestrial Program Milk samples are collected from two herds grazing within three miles of the reactor site (K-34 and K-38 ); from four herds that graze between 3-7 miles of the reactor site (K-3, K-5, K-35, and K-39);

and one from a dairy in Green Bay (K-42), 28.1 miles from the reactor site.

The samples are collected twice per month during the grazing period (May through October) and monthly for the rest of the year. The samples are analyzed for iodine-131, strontium-89 and strontium-90, calcium, stable potassium and gamma-emitting isotopes.

Well Water Groundwater is collected quarterly from the four off-site well locations K-10, K-11, K-13 and K-38 and from two on-site wells located at K-1g and K-1h.

Gamma spectroscopic analysis, tritium and gross beta on the total residue are performed for each water sample. The concentration of potassium-40 is calculated from total potassium. Samples of water from the two on-site wells (K-1 g and K-1 h) are analyzed for gross alpha. Water samples from K-1g are also tested for strontium-89 and strontium-90.

Domestic Meat Domestic meat is collected annually (if available) during the third quarter, from three locations in the vicinity of the plant (K-24, K-29, and K-32). The flesh is separated from the bone and analyzed for gross alpha, gross beta and gamma emitting isotopes.

Eggs are collected quarterly from locations K-24 and K-32. Samples are analyzed for gross beta, strontium-89, strontium-90 and gamma-emitting isotopes.

Vegetables and Grain Annually, during the third quarter, five varieties of vegetables and samples of grain are collected from location K-26. Samples may also be obtained from other local sources to supplement the program (eg., K-3, and K-24). In addition, two varieties of grain or leafy vegetables are collected annually from farmland owned by Dominion Energy Kewaunee (K-23a and K-23b) and rented to a private individual for growing crops. The samples are analyzed for gross beta, strontium-89, strontium-90 and gainma emitting isotopes.

Cattle Feed Cattle feed (e.g., hay and silage) is collected during the first quarter from dairy farm locations (K-3, K-5, K-34, K-35, K-38 and K-39). The samples are analyzed for gross beta, strontium-89, strontium-90 and gamma emitting isotopes.

Grass Grass is collected during the second, third and fourth quarters from twq on-site locations (K-1 band K-1f) and from the dairy farm locations (K-3, K-5, K-34, K-35, K-38 and K-39). The samples are analyzed for gross beta, strontium-89, strontium-90 and gamma emitting isotopes.

Soil Soil samples are collected twice a year on-site at K-1f and from the dairy farm locations (K-3, K-5, K-34, K-35, K-38 and K-39). The samples are analyzed for gross alpha, gross beta, strontium-89, strontium-90 and gamma emitting isotopes.

4

3.1.3 The Aquatic Program Surface Water Surface water samples are taken monthly from three locations on Lake Michigan: 1) at the point where the service water is discharged into Lake Michigan (K-1 d);

2) Two Creeks Park (K-14) located 2.6 miles south of the reactor site; and 3) at the main pumping station located approximately equidistant from Kewaunee and Green Bay, which pumps water from the Rostok water intake (K-9) located 11.5 miles NNE of the reactor site. Both raw and tap water are collected at K-9. One-gallon water samples are taken monthly from three creeks that pass through the site (K-1 a, K-1 b, and K-1 e). Samples from North and Middle Creeks (K-1a, K-1b) are collected near the mouth of each creek. Samples from the South Creek (K-1e) are collected about ten feet downstream from the point where the outflow from the two drain pipes meets. Additionally, the drainage pond (K-1k),

located approximately 0.6 miles southwest of the plant, is included in the sampling program. Water samples at K-14 are collected and analyzed in duplicate.

The water is analyzed for gamma emitting isotopes, gross beta activity in total residue, dissolved and suspended solids, and potassium-40. The concentration of potassium-40 is calculated from the total potassium concentration. In addition, quarterly composites of monthly grab samples are analyzed for tritium, strontium-89 and strontium-90.

Fish samples are collected during the second, third and fourth quarters near location K-1 d. The flesh is separated from the bones, gamma scanned and analyzed for gross beta activity. Bone samples are analyzed for gross beta, strontium-89 and strontium-90. Lafond's Fish Market (K-36) may be used for backup fish samples, if needed.

Aquatic Slime Periphyton algae (slime) or aquatic vegetation is collected during the second and third quarters from three Lake Michigan locations (K-1d, K-9 and K-14), from three creek locations (K-1a, K-1b and K-1e) and from the drainage pond (K-1k), if available. The samples are analyzed for gross beta activity. If the quantity is sufficient, analyses for gamma-emitting isotopes and strontium-89 and strontium-90 activities are performed.

Bottom Sediment Bottom sediments are collected in May and November from five locations (K-1 c, K-1d, K-1j, K-9 and K-14). The samples are analyzed for gross beta, strontium-89, strontium-90 and gamma emitting isotopes.

5

3.1.4 Program Execution Program execution is summarized in Table 4.4. The program was executed for the year 2016 as described in the preceding sections, with the following exceptions:

Air Particulates I Air Iodine No air particulate I air iodine sample (0 m3) was collected at location K-2, for the sample period ending 6/28/16. Power to the sample pump was found off. (CR 689)

A partial air particulate I air iodine sample (262 m3) was collected at location K-31, for the sample period ending 8/16/16. A mechanical failure with the sample pump resulted in a reduced runtime of 145 hours0.00168 days <br />0.0403 hours <br />2.397487e-4 weeks <br />5.51725e-5 months <br />. (CR 746)

A partial air particulate I air iodine sample (281 m3) was collected at location K-41, for the sample period ending 8/16/16. A mechanical failure with the sample pump resulted in a reduced runtime of 156 hours0.00181 days <br />0.0433 hours <br />2.579365e-4 weeks <br />5.9358e-5 months <br />. (CR 7 46)

A partial air particulate I air iodine sample (224 m3) was collected at location K-1f, for the sample period ending 8/23/16. A mechanical failure with the sample pump resulted in a reduced runtime of 124 hours0.00144 days <br />0.0344 hours <br />2.050265e-4 weeks <br />4.7182e-5 months <br />. (CR 756)

A partial air particulate I air iodine sample (189 m3) was collected at location K-31, for the sample period ending 8/23/16. A mechanical failure with the sample pump resulted in a reduced runtime of 105 hours0.00122 days <br />0.0292 hours <br />1.736111e-4 weeks <br />3.99525e-5 months <br />. (CR 756)

A partial air particulate I air iodine sample (155 m3) was collected at location K-41, for the sample period ending 8/23/16. A mechanical failure with the sample pump resulted in a reduced runtime of 86 hours9.953704e-4 days <br />0.0239 hours <br />1.421958e-4 weeks <br />3.2723e-5 months <br />. (CR 756)

A partial air particulate I air iodine sample (169 m3) was collected at location K-8, for the sample period ending 9/20/16. A mechanical failure with the sample pump resulted in a reduced runtime of 94 hours0.00109 days <br />0.0261 hours <br />1.554233e-4 weeks <br />3.5767e-5 months <br />. (CR 784)

The mechanical failures on the air sample pumps were determined to be caused by failure of the carbon blades. (CR746, CR 756 and CR784). When discovered, the sample pumps were replaced with rebuilt pumps and a midweek check for proper operation was completed as a follow up action. Recurring failures happened after this midweek check. When the cause was determined to be a faulty batch of carbon blades, the sample pumps were rebuilt with a carbon blades from a different batch/lot.

3.1.5 Program Modifications None.

6

3.2 RESULTS AND DISCUSSION Results for the reporting period January to December, 2016 are presented in summary form in Table 4.5. For each type of analysis, of each sampled medium, the table shows the annual mean and range for all indicator and control locations. The location with the highest annual mean and the results for this location are also given.

The discussion of the results has been divided into three broad categories: the air, terrestrial, and aquatic environments. Within each category, samples will be discussed in the order listed in Table 4.4.

Any discussion of previous environmental data for the Kewaunee Power Station refers to data collected by Environmental Inc., Midwest Laboratory.

Results of all measurements made in 2016 are not included in this section, although references to these results will be made in the discussion. A complete tabulation of results is provided in Part II of the 2016 annual report on the Radiological Monitoring Program for the Kewaunee Power Station.

3.2.1 Atmospheric Nuclear Detonations and Nuclear Accidents There were no atmospheric nuclear tests or accidents reported in 2016. The Chernobyl and Fukushima Daiichi nuclear accidents occurred on April 26, 1986 and March 11, 2011, respectively.

The last reported atmospheric nuclear test was conducted by the People's Republic of China on October 16, 1980. Contributions from these events have resulted in the presence of long-lived radioisotopes of cesium and strontium still detectable in the environment.

3.2.2 The Air Environment Ambient Gamma Radiation -TLDs Ambient gamma radiation was monitored by TLDs at fourteen locations, eight indicators and six controls. TLDs at the indicator locations measured a mean dose equivalent of 16.5 mR/91 days, in close agreement with the control locations 15.9 mR/91 days. The readings are similar to the averages obtained from 2002 (and prior to) through 2015.

For eight TLDs monitoring the Independent Spent Fuel Storage Installation (Protected Area), (K-1 L through K-1S), measurements averaged 14.5 mR/91 days.

No plant effect on ambient gamma radiation was indicated. These values are lower than the United States average value of 19.5 mR/91 days due to natural background radiation (National Council on Radiation Protection and Measurements, 1975). The highest annual mean was 18.0 mR/91 days, measured at indicator location K-27.

Year Avera e Indicators Avera e Controls Dose rate mR/91 da s 2002 16.1 15.1 2003 14.1 13.7 2004 14.8 14.0 2005 15.7 14.3 2006 16.4 15.0 2007 16.2 15.2 2008 15.6 14.2 2009 15.2 13.9 7

Year AveraQe (Indicators)

AveraQe (Controls)

Dose rate <mR/91 davs) 2010 15.2 14.3 2011 15.0 14.5 2012 16.1 15.3 2013 16.2 15.5 2014 15.0 14.8 2015 16.2 16.1 2016 16.5 15.9 Ambient gamma radiation as measured by thermoluminescent dosimetry.

Average quarterly dose rates.

Using ANSl/HPS N13.37-2014 as guidance, a determination of facility related dose was performed using quarterly TLD data from control and indicator locations from 2005 through 2015. A baseline background dose (B0 ) was computed for each TLD location. Then a Quarterly Minimum Differential Dose (MDD0 )

was calculated as 3 times the 90 1

h percentile of the standard deviations of the historical quarterly results.

The result of this calculation was 6.9 mrem. Transit and storage doses weren't considered since the TLD's currently are, and have historically been, collected in the field and delivered to the laboratory for immediate processing.

2016 results at all locations both indicator and control were lower than the sum of the Baseline Background Dose(B0 ) and the Quarterly Minimum Differential Dose(MDD0 ), which according to ANSl/HPS-N13.37-2014 indicates no detection(ND) which supports the conclusion that there is no plant effect Normalized Quarterly Monitoring Data Quarterly Facility Dose Monitoring Quarterly Mo (mrem per standard quarter)

Fa = Mo - [Bo+MDDo](mrem)

Baseline Location Bo(mrem) 1*t Qtr 2nd Qtr 3rd Qtr 4th Qtr 1*t Qtr 2nd Qtr 3rd Qtr 4th Qtr K-1f 12.9 12.0 16.1 14.6 16.3 ND ND ND ND K-5 17.3 14.7 17.7 17.0 17.7 ND ND ND ND K-17 14.9 13.9 17.6 17.4 17.3 ND ND ND ND K-25 17.3 13.9 18.8 16.9 18.7 ND ND ND ND K-27 16.0 16.3 17.6 20.5 17.6 ND ND ND ND K-30 15.2 15.3 17.3 16.7 17.0 ND ND ND ND K-39 15.6 15.5 18.7 17.0 18.3 ND ND ND ND K-43 16.6 14.9 14.3 14.0 13.9 ND ND ND ND K-2 15.7 15.9 16.4 17.9 16.8 ND ND ND ND K-3 17.0 16.6 17.1 17.5 17.6 ND ND ND ND K-8 14.9 14.8 17.0 17.0 16.9 ND ND ND ND K-15 14.2 12.4 15.7 14.9 15.0 ND ND ND ND K-31 12.5 12.7 13.3 14.5 13.2 ND ND ND ND K-41 14.6 14.9 16.9 20.2 16.0 ND ND ND ND Table assumes 1 roentgen = 1 rem (per NRC -Health Physics Positions Based on 1 O CFR Part 20, October 2015) 8

Airborne Particulates The annual gross beta concentration in air particulates averaged 0.021 pCi/m3 at the indicator location and 0.020 pCi/m3 at the control locations, similar to the means observed from 2002 (and prior to) through 2015. There is no indication of a plant effect, the average readings were evenly distributed between indicator and control locations. New sampler pumps were installed in the third quarter of 2010. The slight increases in beta activity may be due to a change in the calculated volume. Results are tabulated below.

Year Averaoe (Indicators)

Averaqe (Controls)

Concentration <oCi/m3) 2002 0.023 0.023 2003 0.022 0.022 2004 0.019 0.020 2005 0.023 0.023 2006 0.021 0.021 2007 0.022 0.021 2008 0.022 0.022 2009 0.023 0.023 2010 0.023 0.022 2011 0.029 0.029 2012 0.029 0.030 2013 0.024 0.025 2014 0.019 0.019 2015 0.022 0.022 2016 0.021 0.020 Average annual gross beta concentrations in airborne particulates.

Variation in the gross beta activity throughout the year is not unusual. Typically, higher beta averages occur during the months of January and December, and the first and fourth quarters, as noted in data from 2002 through 2016.

Gamma spectroscopic analysis of quarterly composites of air particulate filters yielded similar results for indicator and control locations.

Beryllium-7, produced continuously in the upper atmos:rhere by cosmic radiation, was detected in all samples, with an average activity of 0.070 pCi/m at the indicator locations and an average of 0.069 pCi/m3 at the control locations. All other gamma-emitting isotopes were below their respective LLD limits.

Airborne Iodine Levels of airborne iodine-131 were below the lower limit of detection (LLD) of 0.030 pCi/m3 at all locations. There was no indication of a plant effect on the local air environment.

Precipitation Precipitation was monitored for tritium at indicator location, K-11. The concentration was below the LLD level of 180 pCi/L in all samples.

9

3.2.3 The Terrestrial Environment 126 milk samples were tested for the presence of iodine-131, all measured below an LLD level of 0.5 pCi/L.

Strontium-89 concentrations measured below an LLD level of 1.5 pCi/L in all samples. Measurable levels of strontium-90 above an LLD level of 0.9 pCi/L were detected in six of eighty-four samples tested. Mean values were 0.9 pCi/L for indicator locations and 1.0 pCi/L for control locations and are similar to averages seen from 1990 through 2015.

For gamma emitting isotopes, concentrations measured below the required limits of 15 pCi/L for barium-lanthanum-140 and 10 pCi/L for cesium-134 and cesium-137. Potassium-40 results were comparable at the indicator and control locations (1376 and 1371 pCi/L, respectively), and are consistent with levels observed from 1990 through 2015.

Detection of strontium, iodine and potassium activity is consistent. with findings of the National Center for Radiological Health (1968). Most radiocontaminants in cattlefeed do not find their way into milk, exceptions are radioisotopes of potassium, cesium, strontium, barium, and iodine. Due to chemical* similarities between strontium and calcium, and cesium and potassium, organisms tend to deposit strontium-89 and strontium-90 in bone and cesium-137 in the soft tissue and muscle Consequently, ratios of strontium-90 activity to the weight of calcium in milk and cesium-137 activity to the weight of potassium in milk were monitored in order to detect potential environmental accumulation of these radionuclides. Measured concentrations of calcium are in agreement with previously determined values and averaged 0.99 g/L at the indicator location and 0.96 at the control locations. Measured concentrations of stable Potassium were averaged 1.69 g/L at the indicator locations and 1.67 g/L at the control locations.

There was no indication of any effect due to the operation of the Kewaunee Power Station.

Well Water One of eight samples tested for gross alpha from on-site well K-1 h was slightly above the LLD of 4.8 pCi/L with an activity of 5.0 pCi/L. Gross beta activity above a detection limit of 3.7 pCi/L, was measured in three of the twenty-four indicator samples tested at an average of 12.9 pCi/L. The largest contribution to this average was the sample collected April 41h from location K-38 with a gross beta activity of 29.9 pCi/L. The primary contribution to this high gross beta result was due to naturally-occurring potassium-40 which was detected at an activity of 31.3 pCi/L. It is not unusual to see high potassium-40 levels in an agricultural setting. Potassium-40 is present wherever stable potassium is found. Therefore this result can be attributed to agricultural runoff. The gross alpha activities are most likely contributions from naturally-occurring daughters of radium and thorium when detected in the ground water.

Levels of strontium-89 and strontium-90 were measured for the on-site well (K-1g). The concentrations measured below LLD values of 0.7 and 0.5 pCi/L, respectively.

Samples were tested for tritium and gamma emitting isotopes. All tritium concentrations measured below a detection level of 149 pCi/L. Gamma-emitting isotopes measured below respective LLDs.

Domestic Meat In domestic meat samples, gross alpha measured below the LLD of 0.036 pCi/g wet for both samples tested, while the gross beta concentrations measured 2.79 pCi/g wet and 2.54 pCi/g wet for indicator and control samples respectively. Gamma-spectroscopic analyses showed that most beta activity was due to naturally occurring potassium-40 (2.53 pCi/g wet for the indicator and 2.29 pCi/g wet for the control). AIL other gamma-emitting isotopes measured below detection limits.

10

In samples of eggs tested, the gross beta concentrations averaged 1.58 pCi/g wet at the indicator location and 1.38 pCi/g wet for the control location, similar to observed concentrations of naturally-occurring potassium-40 (1.36 and 1.35 pCi/g wet respectively). Other gamma-emitting isotopes were below their respective LLDs.

Levels of strontium-89 measured less than 0.008 pCi/g wet in all samples. Strontium-90 measured less than 0.003 pCi/g wet in all samples tested.

Vegetables and Grain In vegetables an average gross beta concentration of 2.97 pCi/g wet was measured at the two indicator samples and an average of 2.70 pCi/g wet was measured for the six control samples from location K-26, due primarily to potassium-40 activity. All other gamma emitting isotopes measured below detection levels.

No strontium-89 was detected above an LLD of 0.009 pCi/g wet.

No strontium-90 was detected above an LLD of 0.005 pCi /g wet.

In two samples of grain consisting of clover and wheat collected from indicator location K-23, the gross beta concentrations averaged 7.31 pCi/g wet, due primarily to activity from potassium-40 and beryllium-?. Strontium-89 measured below an LLD of 0.031 pCi/g wet. Strontium-90 was measured at one of the two grain samples from indicator location K-23 at level of 0.031 pCi/g wet. The other sample measured below an LLD of 0.004 pCi/g wet.

These results compare with results from past years and do not indicate a plant effect.

Cattle Feed For cattlefeed, average gross beta concentrations were 12.26 and 12.73 pCi/g wet at the indicator and control locations respectively, and reflected average potassium-40 levels observed of 9.98 and 10.54 pCi/g wet, at the indicator and control locations respectively. No strontium-89 activity was detected above an LLD of 0.044 pCi/g wet. Strontium-90 was measured in five of the eight indicator samples tested at an average activity of 0.018 pCi/g wet. Strontium-90 was also found in three of the four control location samples and averaged 0.017 pCi/g wet.

No plant effect is indicated.

In grass, mean gross beta measured 7.83 and 8.78 pCi/g wet at indicator and control locations, respectively, In all cases the activity was predominantly due to naturally occurring potassium-40 and beryllium-?. Other gamma-emitting isotopes were below respective LLDs.

Strontium-89 tested below detection limits of 0.066 pCi/g wet for all samples and Strontium-90 was measured below the detection limit of 0.026 pCi/g in all samples.

With the exception of the naturally-occurring beryllium and potassium, gamma-emitting isotopes were below detection levels.

Gross alpha concentrations in soil averaged 8.45 pCi/g dry in all ten indicator location samples and 6.96 pCi/g dry at the two control locations. Mean gross beta levels measured at indicator and control locations averaged 28.10 and 24.66 pCi/g dry, respectively, primarily due to potassium-40 activity. Strontium-89 was below an LLD level of 0.11 pCi/g dry in all samples. Strontium-90 was below an LLD of 0.039 pCi/g for all fourteen samples analyzed.

Cesium-137 was detected in all fourteen soil samples at an average of 0.10 pCi/g dry at both the indicator and control locations. Trace levels of Cs-137 in the environment can be attributed to 11

nuclear testing and accidents. Potassium-40 was detected in all samples and averaged 19.98 and 18.08 pCi/g dry for indicator and control locations, respectively. All other gamma-emitting isotopes were below respective LLD's. The levels of detected activities are similar to those observed from 1990 through 2015. The data suggests no evidence of a plant effect.

3.2.4 The Aquatic Environment Surface Water Gross beta activity in surface water measured higher at the indicator locations (5.2 pCi/L) than at the control locations (1.6 pCi/L). A similar pattern of activity has been observed since 1978. In 2016, the highest activities measured were sampled from the K-1a. The average activity was 13.4 pCi/L, with a range of 3.9 to 62.6 pCi/L, due primarily to potassium-40 activity.

The potassium-40 concentrations averaged 12.1 pCi/L and ranged from 3. 7 to 64.1 pCi/L.

Year Averaae (Indicators)

Averaae (Controls)

Gross Beta (oCi/L) 2002 5.7 2.2 2003 7.3 2.4 2004 6.2 2.3 2005 5.2 1.7 2006 5.5 1.8 2007 5.7 1.8 2008 4.7 1.5 2009 4.7 1.5 2010 4.7 1.4 2011 5.0 1.5 2012 6.1 1.4 2013 5.7 1.5 2014 4.4 1.9 2015 4.2 1.4 2016 5.2 1.6 Average annual gross beta concentrations in surface water.

These differences in activity are due in part to the indicator location (K-1 k), a pond formed by drainage of surrounding fields to the southwest. The control sample is Lake Michigan water, which varies very little in gross beta concentration during the year, while indicator samples include the two creek locations (K-1a and K-1e) which are much higher in gross beta concentration and exhibit large month-to-month variations. The K-1a creek draws its water from the surrounding fields which are heavily fertilized; and the K-1e creek draws its water mainly from the Sewage Treatment Plant. In general, gross beta concentrations were high when potassium-40 levels were high and low when potassium-40 levels were low, indicating that fluctuations in beta concentration were due to variations in potassium-40 concentrations and were not due to plant operations.

The fact that similar fluctuations at these locations were observed in pre-operational studies conducted prior to 197 4 supports this assessment.

No tritium was detected above an LLD of 173 pCi/L in the thirty-six samples tested, (quarterly composites of monthly samples).

All analyses for strontium-89 measured below an LLD of 2.0 pCi/L. All analyses for Strontium-90 measured below an LLD of 0. 7 pCi/L.

With the exception of naturally occurring potassium-40, gamma-emitting isotopes measured below their respective LLDs in all samples.

12 4

4

In fish, gross beta concentrations averaged 4.00 pCi/g wet in flesh and 3.19 pCi/g wet in bone fractions. In flesh, the gross beta concentration was primarily due to potassium-40 activity.

Excluding potassium-40, gamma-emitting isotopes measured below their respective LLDs in all samples.

Strontium-89 concentrations in the bone were below an LLD of 0.33 pCi/g wet. Strontium-90 was detected in two of the three samples at an average of 0.18 pCi/g wet.

Aquatic Slime In periphyton algae(slime) and aquatic vegetation samples, mean gross beta concentrations for indicator and control locations measured 3.01 and 6.15 pCi/g wet, respectively, due primarily to combined potassium-40 and beryllium-7 activity of 3.72 and 5.09 pCi/g wet, respectively.

Trace Antimony-125 activity was detected in one of fifteen indicator samples at 0.054 pCi/g wet compared to a detection level of 0.032 pCi/g wet. Cesium-137 was measured in eight of fifteen indicator samples, at a level of 0.012 pCi/g wet. Other gamma-emitting isotopes, with the exception of naturally-occurring beryllium-7 and potassium-40, were below their respective LLDs.

No strontium-89 was measured above the detection level of 0.056 pCi/g wet. Strontium-90 activity was measured at an average of 0.018 pCi/gwet at six of fifteen samples from the indicator locations.

Strontium-90 was also measured at 0.018 pCi/g wet at one of the two control samples tested.

These measurements are consistent with measurements obtained in past years and do not indicate a plant effect.

Bottom Sediments In bottom sediment samples, the mean gross beta concentrations measured an average 8.91 pCi/g dry at the indicator locations versus an average of 18.92 pCi/g dry at the control location.

Cesium-134 measured below the LLD level of 0.020 pCi/g dry for all samples tested. Cesium-137 measured below an LLD of 0.027 pCi/g dry for all locations. Other gamma-emitting isotopes, with the exception of naturally-occurring potassium-40, were below their respective LLDs.

Strontium-89 was measured below an LLD of 0.086 pCi/g dry for all samples. Strontium-90 was measured below an LLD of 0.037 pCi/g dry for all locations.

3.3 LAND USE CENSUS The Land Use Census satisfies the requirements of the KPS Radiological Environmental Monitoring Manual. Section 2.2.2 states:

"A land use census shall be conducted and shall identify within a distance of 8 km (5 mi.) the location, in each of the 10 meteorological sectors, of the nearest milk animal, the nearest residence and the nearest garden of greater than 50m2 (500 ft2) producing broad leaf vegetation." (Figure 4-1)

The 2016 Land Use Census was completed to identify the presence of the nearest milk animals, gardens and farm crops surrounding the Kewaunee Power Station. The Land Use Census was completed on September 6, 2016. The census is conducted annually during the growing season per Health Physics Procedure RP-KW-001-014.

In summary, the highest D/Q locations for nearest garden, nearest residence and nearest milk animal did not change from the 2015 census.

13

3.4 LABO RA TORY PROCEDURES Analytical Procedures used by Environmental, Inc. are on file and are available for inspection.

Procedures are based on those prescribed by the Health and Safety Laboratory of the U.S. Dep't of Energy, Edition 28, 1997, U.S. Environmental Protection Agency for Measurement of Radioactivity in Drinking Water, 1980, and the U.S. Environmental Protection Agency, EERF, Radiochemical Procedures Manual, 1984.

Environmental, Inc., Midwest Laboratory has a comprehensive quality control/quality assurance program designed to assure the reliability of data obtained. Details of the QA Program are presented elsewhere (Environmental, Inc., Midwest Laboratory, 2016). The QA Program includes participation in lnterlaboratory Comparison (crosscheck) Programs. Results obtained are presented in Appendix A.

14

4.0 FIGURES AND TABLES 15

A K-9./!--,

!NTAXE "-r-'

~

  • lli-:lrneAYI

~1'l£R's DAIRYl--t-~~+--~--t i...

SCALE Figure 4-1. Sampling locations, Kewaunee Power Station.

16

L LOCATICINS Ill' -lllRIHI: llEUS SlJIV[Y£I) 8Y STS 1111.utE 21. 200T.

r.UJCAllOllS or W&UA 5111'1'1.Y IEU.S &112 ESTW&lil>.

Fl.ANf PARKING LOT Figure 4-2. Groundwater Monitoring Wells, Kewaunee Power Station.

17

Table 4.1. Sampling locations, Kewaunee Power Station.

Distance (miles)b Code Type 8

and Sector Location K-1 Onsite K-1a 0.62 N North Creek K-1b 0.12 N Middle Creek K-1c 0.10 N 500' north of condenser discharge K-1d 0.10 E Condenser discharge K-1e 0.12 s South Creek K-1f 0.12 s Meteorological Tower K-1g 0.06W South Well K-1h 0.12 NW North Well K-1j 0.10 s 500' south of condenser discharge K-1k 0.60 SW Drainage Pond, south of plant K-11 0.13 N ISFSI Southeast K-1m 0.15 N ISFSI East K-1n 0.16 N ISFSI Northwest K-1o 0.16 N ISFSI North K-1p 0.17 N ISFSI Northwest K-1q 0.16 N ISFSI West K-1r 0.13 N ISFSI West K-1s 0.12 N ISFSI Southwest K-2 c

8.91 NNE WPS Operations Building in Kewaunee K-3 c

5.9 N Lyle and John Siegmund Farm, N2815 Hy 42, Kewaunee K-5 3.2 NNW Ben Paplham Farm, E4160 Old Settlers Rd, Kewaunee K-8 c

4.85WSW St. Isadore the Farmer Church, 18424 Tisch Mills Rd, Tisch Mills K-9 c

11.5 NNE Green Bay Municipal Pumping Station, six miles east of G.reen Bay (sample source is Lake Michigan from Rostok Intake two miles north of Kewaunee.

K-10 1.35 NNE Turner Farm, Kewaunee site K-11 0.96 NW Louise Ihlenfeld! Farm, N879 Hy 42, Kewaunee K-13 c

3.0SSW Rand's General Store, Two Creeks K-14 2.6 s Two Creeks Park, 2.6 miles south of site K-15 c

9.25 NW Gas Substation, 1.5 miles north of Stangelville K-17 I

4.0W Klimesh's' Farm, N885 Tk B, Kewaunee K-23a 0.5W 0.5 miles west of plant, Kewaunee site K-23b 0.6 N 0.6 miles north of plant, Kewaunee site K-24 5.4 N Fictum Farm, N2653 Hy 42, Kewaunee K-25 1.9SW Wotachek Farm, 3968 E. Cty Tk BB, Two Rivers K-26 c

10.8 SSW Wilfert Farms Vegetable Stand (8.0 miles south of "BB")

K-27 1.53 NW Schleis Farm, E4298 Sandy Bay Rd, Kewaunee K-29 5.34W Kunesh Farm, E3873 Cty Tk G, Kewaunee K-30 I

0.8 N End of site boundary K-31 c

6.35 NNW E. Krok Substation, Krok Road K-32 c

7.8 N Piggly Wiggly, 931 Marquette Dr., Kewaunee K-34 I

2.7 N Leon and Vicki Struck, N1549 Lakeshore Dr., Kewaunee K-35 c

6.71 mi. WNW Duane Ducat, N1215 Sleepy Hollow Rd., Kewaunee K-36 8.0 mi NNE Lafond's Fish market, 216 Milwaukee, Kewaunee K-38 2.45mi. WNW Dave Sinkula Farm, N890 Town Hall Road, Kewaunee K-39 3.46 mi. N Francis Wojta, N1859 Lakeshqre Dr., Kewaunee K-41 c

22NW Point Beach-EOF, 3060 Voyager Dr., Green Bay K-42 c

28.1 NW Lamers Dairy Products obtained from Green Bay Markets K-43 2.71 SSW Gary Maigatter Property, 17333 Hwy 42, Two Rivers K-44 2.63 SW Gerald Schleis Property, 4728 Schleis Rd., Two Rivers

  • I = indicator; C = control b Distances are measured from reactor stack.

18

Table 4.2. Type and frequency of collection.

Location Weeklv K-1a K-1b K-1c K-1d K-1e K-1f AP 9,AI K-1a, K-1h K-1i K-1k K-11 throuah K-1s K-2 AP 9,AI K-3, K-5 K-8 AP 9,AI K-9 K-10, K-13 K-11 K-14 K-15, K-17 K-23a, b K-24 K-25 K-26 K-27 K-29 K-30 K-31 AP 9,AI K-32 K-34, K-35 K-36 K-38 K-39 K-41 AP 9,AI K-42 K-43 AP 9,AI K-44

  • Three times a year, second, third and fourth quarters.

bCollected in May and November.

Monthlv SW SW SW SW SW Ml 0

sw; PR swh Ml 0

Ml 0

Ml 0

Ml 0

Ml c Monthly from November through April; semimonthly May through October.

d First quarter (January, February or March) only.

  • Alternate, if milk is not available.

Table 4.3. Sample Codes:

Code Description Al Airborne Iodine AP Airborne particulates BS Bottom sediments CF Cattlefeed DM Domestic Meat EG Eggs Fl Fish GLV Green Leafy Vegetables GRN Grain 19 Quarterlv Semiannuallv Annuallv SL 1 GR" SL 1 BS b Fl a SL 1 BS b SL 1 GR" TLD so WW BS b SL 1 TLD TLD GR" TLD so CF d TLD SL 1 BS b WW WW SL 1 BS b TLD GRN/GLVe EG DM TLD VE/GLVe TLD DM TLD TLD EG DM GR" so CF d Fl a,i GR" WW so CF d GR" TLD so CF d TLD TLD 1 Second and third quarters.

gThe frequency may be increased dependent on the dust loading.

"Two samples are collected, North (K-14a) and South (K-14b) of Two Creeks Road.

1 Two samples, raw and tap water.

'Location dropped, dairy herd was sold in February, 2013.

Code Description GR Grass Ml Milk PR Precipitation SL Slime so Soil SW Surface water TLD Thermoluminescent Dosimeter VE Vegetables WW Well water

Table 4.4. Sampling Summary, January-December, 2016.

Sample Type Air Environment TL D's Airborne particulates Airborne Iodine Precipitation Terrestrial Environment Milk (May-Oct)

(Nov-Apr)

Well water Domestic meat Eggs Vegetables - 5 varieties Grain - clover Cattle feed Grass Soil Aguatic Environment Surface water Fish Slime Bottom sediments Collection Type and Frequency a CIQ C/W C/W CIM GISM GIM GIQ GIA GIQ GIA GIA GIA GITA GISA GIM GITA GISA GISA

  • Type of collection is coded as follows: C =continuous; G =grab.

Number of Locations 22 6

6 7

7 6

2 2

2 3

6 8

7 7

7 5

Frequency is coded as follows: W =weekly; BW =bi-weekly; SM= semimonthly; M =monthly; Number of Samples Collected 88 317 317 12 84 42 24 2

8 6

4 12 24 14 108 3

14 10 Q =quarterly; SA= semiannually; TA= three times per year; A= annually.

20 Number of Samples Missed 0

1 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

Table 4.5 Environmental Radiation Monitoring Program Summary.

Name of Facility Location of Facility Sample Type and Type Number of (Units)

Analyses*

TLDs (Quarterly)

Gamma 56 (mR/91days)

TLDs, Quarterly Gamma 32 (Protected Area)

(mR/91days)

Airborne GB 317 Particulates (pCi/m3)

GS 24 Be-7 Nb-95 Zr-Nb-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Airborne Iodine 1-131 317 (pCi/m 3)

Precipitation H-3 12 (pCi/L)

Milk 1-131 126 (pCi/L)

Sr-89 84 Sr-90 84 GS 126 K-40 Cs-134 Cs-137 Ba-La-140 (g/L)

K-stable 84 (g/L)

Ca 84 Kewaunee Nuclear Power Plant Docket No.

50-305

~~~~~~~~~-

Kewaunee County, Wisconsin Reporting Period January-December, 2016 (County, State)

Indicator Location with Highest Control Number Locations Annual Mean Locations Non-LLDb Mean (F) 0 Mean (F)° Mean (F) 0 Routine Range 0

Locationd Range 0

Range 0

Results*

3.0 16.5 (32132)

K-27, Schlies Farm 18.0 (4/4) 15.9 (24/24) 0 (12.0-20.5) 1.53 NW (16.3-20.5)

(12.4-20.2) 3.0 14.5 (32132)

K-1-S, ISFSI SW 18.6 (4/4) none 0

(9.5-19.4) 0.12 N (17.6-19.4) 0.005 0.021 (106/106)

K-1f, Met. Tower 0.022 (53/53) 0.020 (211/211) 0 (0.005-0.044) 0.12 s (0.009-0.041)

(0.004-0.045) 0.020 0.070 (8/8)

K-2, WPSBldg.

0.074 (4/4) 0.069 (16/16) 0 (0.045-0.092) 8.91 NNE (0.047-0.093)

(0.047-0.093) 0.0024

<LLD

<LLD 0

0.0023

<LLD

<LLD 0

0.0019

<LLD

<LLD 0

0.0097

<LLD

<LLD 0

0.0011

<LLD

<LLD 0

0.0011

<LLD

<LLD 0

0.0029

<LLD

<LLD 0

0.0053

<LLD

<LLD 0

0.03

<LLD

<LLD 0

180

<LLD none 0

0.5

<LLD

<LLD 0

1.5

<LLD

<LLD 0

0.9 0.9 (4/48)

K-3, Siegmund Farm 1.0 (2/12) 1.0 (2136) 0 (0.9-0.9) 5.9 N (1.0-1.0)

(1.0-1.0) 50 1376 (72/72)

K-35, Ducat 1396 (18/18) 1371 (54/54) 0 (1163-1535) 6.71 mi. WNW (1227-1505)

(1168-1505) 8.1

<LLD

<LLD 0

9.2

<LLD

<LLD 0

15.0

<LLD

<LLD 0

1.00 1.69 (48/48)

K-5, Paplham Farm 1.70 (12112) 1.67 (36/36) 0 (1.42-1.82) 3.2 NNW (1.59-1.80)

(1.42-1. 79) 0.40 0.99 (48/48)

K-39, Wojta Farm, 1.01 (12/12)

0. 96 (36/36) 0 (0.87-1.11) 3.46 mi. N (0.88-1.11)

(0.80-1.10) 21

Table 4.5 Environmental Radiation Monitoring Program Summary.

Name of Facility Location of Facility Sample Type and Type Number of (Units)

Analyses" Well Water GA 8

(pCi/L)

GB 24 H-3 24 K-40 24 Sr-89 4

Sr-90 4

GS 24 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Domestic Meat GA 2

(pCi/gwet)

GB 2

GS 2

Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Eggs GB 8

(pCi/gwet)

Sr-89 8

Sr-90 8

GS 8

Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Kewaunee Nuclear Power Plant Docket No.

50-305 Kewaunee County, Wisconsin Reporting Period January-December, 2016 (County, State)

Indicator Location with Highest Control Number Locations Annual Mean Locations Non-LLD" Mean (F)° Mean (F)"

Mean (F)° Routine Range*

Location" Range*

Range*

Results" 4.8 5.0 (1/8)

K-1g, South Well 5 (1/4)

None 0

0.06W 3.7 12.9 (3/20)

K-38, Sinkula 29.9 (1/4)

<LLD 0

(3.9-29.9) 2.45 mi. WNW 149

<LLD

<LLD 0

0.30 3.65 (18/20)

K-38, Sinkula 11.39 (3/4) 0.98 (4/4) 0 (0.60-31.32) 2.45 mi. WNW (1.08-31.32)

(0.96-1.02) 0.7

<LLD None 0

0.5

<LLD None 0

5.1

<LLD

<LLD 0

11.9

<LLD

<LLD 0

4.3

<LLD

<LLD 0

4.4

<LLD

<LLD 0

7.9

<LLD

<LLD 0

5.6

<LLD

<LLD 0

6.1

<LLD

<LLD 0

5.3

<LLD

<LLD 0

7.5

<LLD

<LLD 0

0.036

<LLD

<LLD 0

0.10 2.79 (1/1)

K-24, Fictum Farm 2.79 (1/1) 2.54 (1/1) 0 5.4 mi. N 0.32

<LLD

<LLD 0

0.50 2.53 (1/1)

K-24, Fictum Farm 2.53 (1/1) 2.29 (1/1) 0 5.45 mi. N 0.044

<LLD

<LLD 0

0.055

<LLD

<LLD 0

0.037

<LLD

<LLD 0

0.18

<LLD

<LLD 0

0.022

<LLD

<LLD 0

0.022

<LLD

<LLD 0

0.067

<LLD

<LLD 0

0.16

<LLD

<LLD 0

0.008 1.58 (4/4)

K-24, Fictum Farm 1.58 (4/4) 1.38 (4/4) 0 (1.42-1.72) 5.45 mi. N (1.42-1.72)

(1.21-1.48) 0.008

<LLD

<LLD 0

0.003

<LLD

<LLD 0

0.074

<LLD

<LLD 0

0.50 1.36 (4/4)

K-24, Fictum Farm 1.36 (4/4) 1.35 (4/4) 0 (1.18-1.69) 5.45 mi. N (1.18-1.69)

(1.23-1.57) 0.012

<LLD

<LLD 0

0.017

<LLD

<LLD 0

0.015

<LLD

<LLD 0

0.058

<LLD

<LLD 0

0.007

<LLD

<LLD 0

0.006

<LLD

<LLD 0

0.039

<LLD

<LLD 0

0.063

<LLD

<LLD 0

22

Table 4.5 Environmental Radiation Monitoring Program Summary.

Name of Facility Location of Facility Sample Type and Type Number of (Units)

Analyses a Vegetables GB 8

(pCi/gwet)

Sr-89 8

Sr-90 8

GS 8

Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Grain -

GB 2

(Wheat, Clover)

(pCi/gwet)

Sr-89 2

Sr-90 2

GS 2

Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Cattlefeed GB 12 (pCi/gwet)

Sr-89 12 Sr-90 12 GS 12 Be-7 K-40 Kewaunee Nuclear Power Plant Docket No.

50-305 Kewaunee County, Wisconsin Reporting Period January-December, 2016 (County, State)

Indicator Location with Highest Control Number Locations Annual Mean Locations Non-LLD D Mean (F)° Mean (Ff Mean (F)° Routine Range*

Location ° Range 0

Range 0

Results*

0.010 2.97 (2/2)

K-26, Wilfert Farms 2.70 (6/6) 2.70 (6/6) 0 (2.75-3.15) 9.1 SSW (1.88-4.37)

(1.88-4.37) 0.009

<LLD

<LLD 0

0.005

<LLD

<LLD 0

0 0.16

<LLD

<LLD 0

0.50 2.11 (2/2)

K-26, Wilfert Farms 2.36 (6/6) 2.36 (6/6) 0 (1.97-2.24) 9.1 SSW (1.55-4.15)

(1.55-4.15) 0.012

<LLD

<LLD 0

0.008

<LLD

<LLD 0

0.006

<LLD

<LLD 0

0.06

<LLD

<LLD 0

0.006

<LLD

<LLD 0

0.007

<LLD

<LLD 0

0.016

<LLD

<LLD 0

0.052

<LLD

<LLD 0

0.010 7.31 (2/2)

K-23, Kewaunee 7.31 (2/2) 0 (5.12-9.50)

Site, 0.5 mi. W (5.12-9.50) 0.031

<LLD 0

0.004 0.031 (1/2)

K-23, Kewaunee 0.031 (1/2) 0 Site, 0.5 mi. W 0.082 0.76 (2/2)

K-23, Kewaunee 0.76 (2/2) 0 (0.58-0.94)

Site, o.5 mi. W (0.58-0.94) 0.50 4.92 (2/2)

K-23, Kewaunee 4.92 (2/2) 0 (3.85-5.99)

Site, 0.5 mi. W (3.85-5.99) 0.011

<LLD

<LLD 0

0.021

<LLD

<LLD 0

0.013

<LLD

<LLD 0

0.09

<LLD

<LLD 0

0.011

<LLD

<LLD 0

0.015

<LLD

<LLD 0

0.019

<LLD

<LLD 0

0.07

<LLD

<LLD 0

0.10 12.26 {8/8)

K-39, Wojta Farm 14.10 (2/2) 12.73 (4/4) 0 (3.89-22.56) 3.46 mi. N (10.15-18.05)

(4.92-19.34) 0.044

<LLD

<LLD 0

0.016 0.018 (5/8)

K-38, Sinkula Farm 0.026 (1/2) 0.017 (3/4) 0 (0.005-0.026) 2.45 mi. WNW (0.005-0.023) 0.23 0.50 (5/8)

K-5, Paplham Farm 1.37 (1/2) 0.45 (214) 0 (0.13-1.37) 3.2 NNW (0.31-0.58) 0.10 9.98 (8/8)

K-39, Wojta Farm 11.48 (2/2) 10.54 (4/4) 0 (2.99-17.69) 3.46 mi. N (7.86-15.10)

(3.50-18.30) 23

Table 4.5 Environmental Radiation Monitoring Program Summary.

Name of Facility Location of Facility Sample Type and Type Number of (Units)

Analyses" Cattlefeed Nb-95 (continued)

Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Grass GB 24 (pCi/gwet)

Sr-89 24 Sr-90 24 GS 24 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Soil GA 14 (pCi/gdry)

GB 14 Sr-89 14 Sr-90 14 GS 14 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Kewaunee Nuclear Power Plant Docket No.

50-305 Kewaunee County, Wisconsin Reporting Period January-December, 2016 (County, State)

Indicator Location with Highest Control Number Locations Annual Mean Locations Non-LLD" Mean (Ff Mean (I-)

Mean (Ff Routine Range" Location" Range" Range" Results" 0.029

<LLD

<LLD 0

0.052

<LLD

<LLD 0

0.029

<LLD

<LLD 0

0.22

<LLD

<LLD 0

0.030

<LLD

<LLD 0

0.030

<LLD

<LLD 0

0.051

<LLD

<LLD 0

0.23

<LLD

<LLD 0

0.10 7.83 (18/18)

K-3, Siegmund Farm 10.00 (3/3) 8.78 (6/6) 0 (5.48-9.94) 5.9 N (8.54-12.09)

(6.4-12.09) 0.066

<LLD

<LLD 0

0.026

<LLD

<LLD 0

2.36 (18/18)

K-1b, Middle Creek 3.05 (3/3) 1.63 (6/6) 0 (0.36-6.31) 0.12 N (0.79-5.33)

(0.26-3.81) 0.50 6.59 (18/18)

K-5, Paplham Farm 7.42 (3/3) 7.16 (6/6) 0 (4.67-8.72) 3.2 NNW (6.35-8.72)

(6.97-9.11) 0.010

<LLD

<LLD 0

0.014

<LLD

<LLD 0

0.012

<LLD

<LLD 0

0.10

<LLD

<LLD 0

0.009

<LLD

<LLD 0

0.010

<LLD

<LLD 0

0.013

<LLD

<LLD 0

0.067

<LLD

<LLD 0

4.6 8.45 (10/10)

K-1f, Met Tower 9.52 (2/2) 6.96 (4/4) 0 (7.53-9.79) 0.12 s (9.25-9. 79)

(4.12-7.98) 2.0 28.10 (10/10)

K-38, Sinkula Farm 31.46 (2/2) 24.66 (4/4) 0 (24.77-32.63) 2.45 mi. WNW (30.29-32.63)

(22.66-28.33) 0.11

<LLD

<LLD 0

0.039

<LLD

<LLD 0

0.50

<LLD

<LLD 0

1.4 19.98 (10/10)

K-38, Sinkula Farm 22.51 (2/2) 18.08 (4/4) 0 (17. 75-23.22) 2.45 mi. WNW (21.80-23.22)

(16.22-19.50) 0.080

<LLD

<LLD 0

0.093

<LLD

<LLD 0

0.068

<LLD

<LLD 0

0.30

<LLD

<LLD 0

0.034

<LLD

<LLD 0

0.000 0.10(10/10)

K-3, Siegmund Farm 0.12 (2/2) 0.10 (4/4) 0 (0.06-0.13) 5.9 N (0.11-0.13)

(0.07-0.13) 0.15

<LLD

<LLD 0

0.22

<LLD

<LLD 0

24

Table 4.5 Environmental Radiation Monitoring Program Summary.

Name of Facility Location of Facility Sample Type and Type Number of (Units)

Analyses" Surface Water GB(TR) 108 (pCi/L)

GS 108 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 H-3 36 Sr-89 36 Sr-90 36 K-40 108 Fish (Muscle)

GB 3

(pCi/gwet)

GS 3

K-40 Mn-54 Fe-59 Co-58 Co-60 Cs-134 Cs-137 Fish (Bones)

GB 3

(pCi/gwet)

Sr-89 3

Sr-90 3

Kewaunee Nuclear Power Plant Docket No.

50-305 Kewaunee County, Wisconsin Reporting Period January-December, 2016 (County, State)

Indicator Location with Highest Control Number Locations Annual Mean Locations Non-LLD 0

Mean (F) 0 Mean (Ft Mean (F) 0 Routine Range 0

Location" Range 0

Range 0

Results" 1.5 5.2 (84/84)

K-1 a, North Creek 13.4 (12/12) 1.6 (24/24) 0 (1.1-62.6) 0.62 N (3.9-62.6)

(0.6-2.3) 15

<LLD

<LLD 0

30

<LLD

<LLD 0

15

<LLD

<LLD 0

15

<LLD

<LLD 0

30

<LLD

<LLD 0

15

<LLD

<LLD 0

10

<LLD

<LLD 0

10

<LLD

<LLD 0

15

<LLD

<LLD 0

173

<LLD

<LLD 0

2.0

<LLD

<LLD 0

0.7

<LLD

<LLD 0

0.87 4.1 (84/84)

K-1a, North Creek 12.1 (12/12) 1.2 (24/24) 0 (1.1-64.1) 0.62 N (3.7-64.1)

(1.0-1.3) 0.5 4.00 (3/3)

K-1d, Cond. Discharge 4.00 (3/3)

None 0

(3.45-4.51) 0.10 mi. E (3.45-4.51) 0.5 3.58 (3/3)

K-1d, Cond. Discharge 3.58 (3/3)

None 0

(3.39-3.76) 0.10 mi. E (3.39-3.76) 0.030

<LLD None 0

0.072

<LLD None 0

0.026

<LLD None 0

0.018

<LLD None 0

0.030

<LLD None 0

0.037

<LLD None 0

0.5 3.19 (3/3)

K-1d, Cond. Discharge 3.19 (3/3)

None 0

(2.13-4.48) 0.10 mi. E (2.13-4.48) 0.33

<LLD None 0

0.11 0.18 (2/3)

K-1d, Cond. Discharge 0.18 (2/3)

None 0

(0.18-0.18) 0.10 mi. E (0.18-0.18) 0 25

Table 4.5 Environmental Radiation Monitoring Program Summary.

Kewaunee Nuclear Power Plant Docket No.

50-305 Name of Facility Location of Facility Kewaunee County, Wisconsin Reporting Period January-December, 2016 (County, State)

Indicator Location with Highest Control Nuinber Sample Type and Locations Annual Mean Locations Non-Type Number of LLD 0

Mean (F) 0 Mean (F)

Mean (F) 0 Routine (Units)

Analyses" Range" Location" Range 0

Range 0

Results*

Periphyton GB 17 0.10 3.01 (15/15)

K-9, Rostok Intake 6.15 (2/2) 6.15 (2/2) 0 (Algae)

(0.87-5.28) 11.5 NNE (5.99-6.30)

(5.99-6.30)

(pCi/gwet)

Sr-89 17 0.056

<LLD

<LLD 0

Sr-90 17 0.014

0. 018 (6/15)

K-1b,Middle Creek 0.022 (3/5) 0.018 (1/2) 0 (0.007-0.030) 0.12 N GS 17 Be-7 0.75 (13/15)

K-1e, South Creek 0.94 (4/4) 0.37 (2/2) 0 (0.15-2.29) 0.12 s (0.22-1.32)

(0.16-0.58)

K-40 0.5 2.97 (15/15)

K-9, Rostok Intake 4.72 (2/2) 4.72 (2/2) 0 (1.00-4. 73) 11.5 NNE (4.49-4.94)

(4.49-4.94)

Mn-54 0.008

<LLD

<LLD 0

Co-58 0.008

<LLD

<LLD 0

Co-60 0.018

<LLD

<LLD 0

<LLD Nb-95 0.019

<LLD

<LLD 0

Zr-95 0.016

<LLD

<LLD 0

Ru-103 0.013

<LLD

<LLD 0

Ru-106 0.06

<LLD

<LLD 0

Cs-134 0.007

<LLD

<LLD 0

Cs-137 0.008

0. 012 (8/15)

K-1d, Cond. Discharge 0.016 (3/3)

<LLD 0

(0.005-0.024) 0.10 mi. E (0.012-0.024)

Ce-141 0.025

<LLD

<LLD 0

Ce-144 0.04

<LLD

<LLD 0

Sb-125 0.032 0.054 (1/15)

K-1d, Cond. Discharge 0.054 (1/3) 0.10 mi. E Bottom GB 10 1.0 8.91 (8/8)

K-9, Rostok Intake 18.92 (2/2) 18.92 (2/2) 0 Sediments (6.08-10.26) 11.5 NNE (18.80-19.04)

(18.8-19.04)

(pCi/gdry)

Sr-89 10 0.086

<LLD

<LLD 0

Sr-90 10 0.037

<LLD

<LLD 0

GS 10 K-40 0.5 5.76 (8/8)

K-9, Rostok Intake 13.07 (2/2) 13.07 (2/2) 0 (3.66-6.86) 11.5 NNE (12.30-13.83)

(12.30-13.83)

Co-58 0.038

<LLD

<LLD 0

Co-60 0.024

<LLD

<LLD 0

Cs-134 0.020

<LLD

<LLD 0

Cs-137 0.027

<LLD

<LLD 0

  • GA= gross alpha, GB = gross beta, GS = gamma spectroscopy, TR = total residue.

0 LLD = nominal lower limit of detection based on a 4.66 sigma counting error for background sample.

0 Mean and range are based on detectable measurements only (i.e., >LLD) Fraction of detectable measurements at specified locations is indicated in parentheses (F).

0 Locations are specified by station code (Table 4.1) and distance (miles) and direction relative to reactor site.

  • Non-routine results are ttiose which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

26

Table 4.6 Land Use Census 2

The following table lists an inventory of residence, gardens <!: 500 ft and milk animals found nearest to the plant in each of the 10 meteorological sectors within a five mile radius of the Kewaunee Power Station. (Figure 4-1)

Sector Township No.

Residence Garden Milk Animals Distance From Location ID Plant (miles)

A 1

x 4.62 A

12 x

3.71 A

24 x

1.12 B

18 x

2.70 K-34 B

24 x

1.01 K-10 B

18 x

2.12 R

23 x

x 2.16 R

26 x

0.96 K-11 Q

23 x

1.27 Q

23 x

x 1.53 K-27 p

27 x

x 2.45 K-38 p

26 x

1.35 N

26 x

1.03 N

28 x

2.37 N

35 x

0.94 M

3 x

2.47 M

35 x

1.38 M

4 x

2.89 L

35 x

x 1.00 L

4 x

3.26 K

15 x

3.40 K

36 x

x 0.91 J

11 x

x (Note 2) 2.72 Note 1. Bold Type denotes change from previous census.

Note 2. There were no milk animals located in Sector J within five miles of the Kewaunee Power Station.

No changes to the nearest residence, nearest garden or nearest milk animal locations were identified.

27

5.0 REFERENCES

Arnold. J. R. and H. A. Al-Salih. 1955. Beryllium-7 Produced by Cosmic Rays. Science 121: 451-453.

Eisenbud, M. 1963. Environmental Radioactivity, McGraw-Hill, New York, New York, pp. 213, 275, and 276.

Gold, S., H. W. Barkhau, B. Shlein, and B. Kahn, 1964 Measurement of Naturally Occurring Radionuclides in Air, in the Natural Radiation Environment, University of Chicago Press, Chicago, Illinois, 369-382.

AT.I Environmental, Inc., Midwest Laboratory.

____ 2001 to 2014. Annual Report. Radiological Monitoring Program for the Kewaunee Power Station, Kewaunee, Wisconsin, Final Report, Part II, Data Tabulations and Analysis, January - December 2000 - 2014.

____ 1984 to 2000. (formerly Teledyne Brown Engineering Environmental Services, Midwest Laboratory)

Annual Reports. Radiological Monitoring Program for the Kewaunee Power Station, Kewaunee, Wisconsin, Final Report, Part II, Data Tabulations and Analysis, January-December 1983 through January-December 1999.

____ 1979 to 1983.

(formerly Hazleton Environmental Sciences Corporation)

Annual Reports.

Radiological Monitoring for the Kewaunee Power Station, Kewaunee, Wisconsin, Final Report - Part II, Data Tabulations and Analysis, January-December, 1978 through 1982.

____ 1977 to 1978.

(formerly NALCO Environmental Sciences Corporation)

Annual Reports.

Radiological Monitoring for the Kewaunee Power Station, Kewaunee, Wisconsin, Final Report - Part II, Data Tabulations and Analysis, January-December, 1976 to 1977.

____ 2016.

Quality Manual, Rev. 2, 9 May 2016.

____ 2012.

Quality Assurance Program Manual, Rev. 3, 14 November 2012.

____ 2009.

Quality Control Procedures Manual, Rev. 2, 08 July 2009.

____ 2009.

Quality Control Program, Rev. 2, 12 November 2009.

Industrial BIO-TEST Laboratories, Inc. 1974.

Annual Report.

Pre-operational Radiological Monitoring Program for the Kewaunee Power Station. Kewaunee, Wisconsin. January - December 1973.

Industrial BIO-TEST Laboratories, Inc. 1975 Semi-annual Report. Radiological Monitoring Program for the Kewaunee Power Station, Kewaunee, Wisconsin. Jan. - June, 1975.

National Center for Radiological Health. 1968. Section 1. Milk Surveillance. Radiological Health Data Rep., December 9:

730-746.

National Council on Radiation Protection and Measurements. 1975. Natural Radiation Background in the United States.

NCRP Report No. 45.

Solon, L. R., W. M. Lowder, A. Shambron, and H. Blatz. 1960. Investigations of Natural Environmental Radiation. Science.

131: 903-906.

U.S. Environmental Protection Agency, 2007.

RadNet, formerly Environmental Radiation Ambient Monitoring System, Gross Beta in Air (WI) 1981 - 2000.

Wilson, D.W., G. M. Ward, and J.E. Johnson, 1969. Environmental Contamination by Radioactive Materials. International Atomic Energy Agency, p. 125 American National Standards Institute/Health Physics Society (ANSl/HPS) N13.37 - 2014, Environmental Dosimetry - Criteria for System Design and Implementation.

28

~*L All Eqvironmental, Inc.

'+" l'"'\\I Midwest Laboratory 700 Landwehr Road* Northbrook, IL 60062-2310 phone (847) 564-0700 *fax (847) 564-4517 NOTE:

APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD lntercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

January, 2016 through December, 2016

Appendix A lnterlaboratorv Comparison Program Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the RAD PT Study Proficiency Testing Program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

Table A-2 lists results for thermoluminescent dosimeters (TLDs), via irradiation and evaluation by the University of Wisconsin-Madison Radiation Calibration Laboratory at the University of Wisconsin Medical Radiation Research Center.

Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve months. Acceptance is based on the differe11ce of the results being less than the sum of the errors.

Complete analytical data for duplicate analyses is available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

Results in Table A-7 were obtained through participation in the MRAD PT Study Proficiency Testing Program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).

Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteria in Table A-3 is set at +/- 2 sigma.

Out-of-limit results are explained directly below the result.

A1

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSES" Analysis Gamma Emitters Strontium-89b Strontium-90b Potassium-40 Gross alpha Gross beta Tritium Radium-226,-228 Plutonium lodine-131, lodine-129b Uranium-238, Nickel-63b Technetium-99b lron-55b Other Analyses b Level 5 to 100 pCi/liter or kg

> 100 pCi/liter or kg 5 to 50 pCi/liter or kg

> 50 pCi/liter or kg 2 to 30 pCi/liter or kg

> 30 pCi/liter or kg

<:: 0.1 g/liter or kg

20 pCi/liter

> 20 pCi/liter

100 pCi/liter

> 100 pCi/liter

4,000 pCi/liter

> 4,000 pCi/liter

<:: 0.1 pCi/liter

<:: 0.1 pCi/liter, gram, or sample

55 pCi/liter

> 55 pCi/liter

35 pCi/liter

> 35 pCi/liter 50 to 100 pCi/liter

> 100 pCi/liter a From EPA publication, "Environmental Radioactivity Laboratory lntercomparison Studies Program", Fiscal Year, 1981-1982, EPA-600/4-81-004.

b Laboratory limit.

A2 One standard deviation for single determination 5.0 pCi/liter 5% of known value 5.0 pCi/liter 10% of known value 5.0 pCi/liter 10% of known value 5% of known value 5.0 pCi/liter 25% of known value 5.0 pCi/liter 5% of known value

+/- 10' =

169.85 x (known)0*0933 10% of known value 15% of known value 10% of known value 6 pCi/liter 10% of known value 6 pCi/liter 15% of known value 10 pCi/liter 10% of known value 20% of known value

TABLEA-1. lnterlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)*.

RAD study Concentration (pCi/L)

Lab Code Date Analysis Laboratory ERA Control Result Result Limits Acceptance ERW-1392 4/4/2016 Sr-89 43.5 +/- 4.3 48.2 37.8 - 55.6 Pass ERW-1392 4/4/2016 Sr-90 27.5+/-1.9 28.5 20.7 - 33.1 Pass ERW-1394 b 4/4/2016 Ba-133 65.2 +/- 3.8 58.8 48.7 - 64.9 Fail ERW-1394 c 4/4/2016 Ba-133 57.8 +/- 5.3 58.8 48.7 - 64.9 Pass ERW-1394 4/4/2016 Cs-134 43.7 +/- 3.0 43.3 34.6 -47.6 Pass ERW-1394 4/4/2016 Cs-137 86.1 +/- 5.3 78.4 70.6 - 88.9 Pass ERW-1394 4/4/2016 Co-60 108 +/-44 102 91.8 -114 Pass ERW-1394 4/4/2016 Zn-65 240+/-13 214 193 - 251 Pass ERW-1397 4/4/2016 Gr. Alpha 52.0 +/- 2.2 62.7 32.9 - 77.8 Pass ERW-1397 4/4/2016 Gr. Beta 33.9+/-1.2 39.2 26.0 -46.7 Pass ERW-1400 4/4/2016 1-131 24.7 +/- 0.6 26.6

. 22.1 -31.3 Pass ERW-1402 4/4/2016 Ra-226 15.6 +/- 0.5 15.2 11.3-17.4 Pass ERW-1402 4/4/2016 Ra-228 5.28 +/- 0.76 5.19 3.12 - 6.93 Pass ERW-1403 4/4/2016 Uranium 4.02 +/- 0.42 4.64 3.39 - 5.68 Pass ERW-1405 4/4/2016 H-3 8,150 +/- 270 7,840 6,790 - 8,620 Pass SPW-2845 7/7/2015 Ba-133 60.3 +/- 5.7 64.7 53.9 - 71.2 Pass SPW-2845 7/7/2015 Cs-134 48.8 +/- 9.3 50.1 40.3 - 55.1 Pass SPW-2845 7/7/2015 Cs-137 101 +/- 8 89.8 80.8 - 101 Pass SPW-2845 7/7/2015 Co-60 65.1 +/- 5.8 59.9

. 53.9 - 68.4 Pass SPW-2845 717/2015 Zn-65 288 +/- 29 265 238 - 310 Pass ERW-3485 7/11/2016 Sr-89 43.3 +/- 6.5 53.3 42.3 - 60.9 Pass ERW-3485 7/11/2016 Sr-90 39.0 +/- 2.8 39.2 28.8 - 45.1 Pass ERW-3487 7/11/2016 Ba-133 83.3 +/-4.9 82.9 69.7 - 91.2 Pass ERW-3487 7/11/2016 Cs-134 62.5 +/-4.4 65.3 53.1 - 71.8 Pass ERW-3487 7/11/2016 Cs-137 98.1 +/- 5.6 95.2 85.7 - 107 Pass ERW-3487 7/11/2016 Co-60 122 +/- 5 117 105 - 131 Pass ERW-3487 7/11/2016 Zn-65 124 +/- 9 113 102 - 134 Pass ERW-3490 7/11/2016 Gr. Alpha 46.6 +/- 2.2 48.1 25.0 - 60.5 Pass ERW-3490 7/11/2016 Gr. Beta 26.8 +/- 1.1 28.6 18.2 - 36.4 Pass ERW-3492 7/11/2016 1-131 23.7 +/- 1.0 24.9 20.7 -29.5 Pass ERW-3493 7/11/2016 Ra-226 12.9 +/- 0.4 12.3 9.2 - 14.2 Pass ERW-3493 7/11/2016 Ra-228 5.8 +/- 0.8 5.8 3.5 - 7.6 Pass ERW-3493 7/11/2016 Uranium 32.8 +/- 0.8 25.2 28.4 - 39.3 Pass ERW-3495 7/11/2016 H-3 12,400 +/- 334 12,400 10,800 - 13,600 Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates {ERA).

b No reason determined for failure of Ba-133 result.

0 The result of reanalysis (Compare to original result, footnoted "b" above).

Al-1

TABLE A-2. Thermoluminescent Dosimetry, (TLD, CaS04: Dy Cards).

ab mrem Lab Code Irradiation Delivered Reported Performance c Date Description Dose Dose Quotient (P)

Environmental, Inc.

Group 1 2016-1 10/7/2016 Spike 1 135.0 148.3 0.10 2016-1 10/7/2016 Spike 2 135.0 144.3 0.07 2016-1 10/7/2016 Spike 3 135.0 133.2

-0.01 2016-1 10/7/2016 Spike 4 135.0 139.6 0.03 2016-1 10/7/2016 Spike 5 135.0 128.4

-0.05 2016-1 10/7/2016 Spike 6 135.0 123.9

-0.08 2016-1 10/7/2016 Spike 7 135.0 124.0

-0.08 2016-1 10/7/2016 Spike 8 135.0 121.5

-0.10 2016-1 10/7/2016 Spike 9 135.0 148.3 0.10 2016-1 101712016 Spike 10 135.0 126.8

-0.06 2016-1 10/7/2016 Spike 11 135.0 123.3

-0.09 2016-1 1017/2016 Spike 12 135.0 137.9 0.02 2016-1 10/7/2016 Spike 13 135.0 126.0

-0.07 2016-1 10/7/2016 Spike 14 135.0 127.2

-0.06 2016-1 10/7/2016 Spike 15 135.0 144.5 0.07 2016-1 1017/2016 Spike 16 135.0 140.5 0.04 2016-1 10/7/2016 Spike 17 135.0 146.0 0.08 2016-1 10/7/2016 Spike 18 135.0 127.7

-0.05 2016-1 10/7/2016 Spike 19 135.0 146.8 0.09 2016-1 10/7/2016 Spike 20 135.0 122.6

-0.09 2016-1 1017/2016 Spike 21 135.0 108.6

-0.20 2016-1 10/7/2016 Spike 22 135.0 119.6

-0.11 2016-1 10/7/2016 Spike 23 135.0 135.1 0.00 2016-1 10/7/2016 Spike 24 135.0 116.2

-0.14 2016-1 10/7/2016 Spike 25 135.0 118.9

-0.12 2016-1 10/7/2016 Spike 26 135.0 128.5

-0.05 2016-1 10/7/2016 Spike 27 135.0 115.6

-0.14 2016-1 10/7/2016 Spike 28 135.0 126.4

-0.06 2016-1 10/7/2016 Spike 29 135.0 115.0

-0.15 2016-1 10/7/2016 Spike 30 135.0 147.3 0.09 Mean (Spike 1-30) 130.4 0.03 Passd Standard Deviation (Spike 1-30) 11.5 0.09 Passd

  • Table A-2 assumes 1 roentgen = 1 rem (NRG -Health Physics Questions and Answers 1 O CFR Part 20 - Question 96 - Page Last Reviewed/Updated Thursday, October 01, 2015).

b TLD's were irradiated by the University of Wisconsin-Madison Radiation Calibration Laboratory following ANSI N13.37 protocol from a known air kerma rate. TLD's were read and the results were submitted by Environmental Inc. to the University of Wisconsin-Madison Radiation Calibration Laboratory for comparison to the delivered dose.

0 Performance Quotient (P) is calculated as ((reported dose - conventially true value) + conventially true value) where the conventially true value is the delivered dose.

d Acceptance is achieved when neither the absolute value of mean of the P values, nor the standard deviation of the P values exceed 0.15.

A2-1

TABLE A-2 Thermoluminescent Dosimetry, (TLD, CaS04: Dy Cards). ab mrem Lab Code Irradiation Delivered Reported Performance c Date Description Dose Dose Quotient (P)

Environmental, Inc.

Group 2 2016-2 10/7/2016 Spike 31 87.0 83.0

-0.05 2016-2 10/7/2016 Spike 32 87.0 88.3 0.01 2016-2 1017/2016 Spike 33 87.0 83.1

-0.04 2016-2 10/7/2016 Spike 34 87.0 81.4

-0.06 2016-2 10/7/2016 Spike 35 87.0 78.9

-0.09 2016-2 10/7/2016 Spike 36 87.0 80.3

-0.08 2016-2 10/7/2016 Spike 37 87.0 101.1 0.16 2016-2 10/7/2016 Spike 38 87.0 78.3

-0.10 2016-2 10/7/2016 Spike 39 87.0 86.6 0.00 2016-2 10/7/2016 Spike 40 87.0 81.8

-0.06 2016-2 10/7/2016 Spike 41 87.0 84.8

-0.03 2016-2 10/7/2016 Spike 42 87.0 79.9

-0.08 2016-2 10/7/2016 Spike 43 87.0 80.8

-0.07 2016-2 10/7/2016 Spike 44 87.0 80.2

-0.08 2016-2 10/7/2016 Spike 45 87.0 82.7

-0.05 2016-2 10/7/2016 Spike 46 87.0 104.0 0.20 2016-2 10/7/2016 Spike 47 87.0 86.1

-0.01 2016-2 10/7/2016 Spike 48 87.0 104.0 0.20 2016-2 10/7/2016 Spike49 87.0 86.1

-0.01 2016-2 10/7/2016 Spike 50 87.0 90.8 0.04 2016-2 10/7/2016 Spike 51 87.0 85.7

-0.01 2016-2 10/7/2016 Spike 52 87.0 86.5

-0.01 2016-2 1017/2016 Spike 53 87.0 86.4

-0.01 2016-2 10/7/2016 Spike 54 87.0 92.6 0.06 2016-2 10/7/2016 Spike 55 87.0 88.6 0.02 2016-2 1017/2016 Spike 56 87.0 78.9

-0.09 2016-2 10/7/2016 Spike 57 87.0 82.6

-0.05 2016-2 10/7/2016 Spike 58 87.0 80.6

-0.07 2016-2 10/7/2016 Spike 59 87.0 89.9 0.03 2016-2 10/7/2016 Spike 60 87.0 85.0

-0.02 Mean (Spike 31-60) 86.0 0.01 Passd Standard Deviation (Spike 31-60) 6.9 0.08 Pass ct

~

I a Table A-2 assumes 1 roentgen = 1 rem (NRG -Health Physics Questions and Answers 10 CFR Part 20 - Question 96 - Page Last Reviewed/Updated Thursday, October 01, 2015).

b TLD's were irradiated by the University of Wisconsin-Madison Radiation Calibration Laboratory following ANSI N13.37 protocol from a known air kerma rate. TLD's were read and the results were submitted by Environmental Inc. to the University of Wisconsin-Madison Radiation Calibration Laboratory for comparison to the delivered dose.

0 Performance Quotient (P) is calculated as ((reported dose - conventially true value) + conven!ially true value) where the conventially true value is the delivered dose.

d Acceptance is achieved when neither the absolute value of mean of the P values, nor the standard deviation of the P values exceed 0.15.

A2-2

TABLE A-3. In-House "Spiked" Samples Concentration a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 ° Activity Limits d Acceptance SPW-290 1/21/2016 Sr-90 38.6 +/- 1.5 37.3 22.4 - 52.2 Pass SPW-292 1/21/2016 Sr-90 35.8 +/- 1.6 37.3 22.4 - 52.2 Pass SPW-294 1/21/2016 C-14 4,689 +/- 18 4,735 2,841 - 6,629 Pass SPW-414 2/1/2016 Ra-228 18.4 +/- 2.2 17.7 10.6 - 24.8 Pass W-020416 2/4/2016 Gr. Alpha 20.8 +/- 0.4 20.1 12.0 - 28.1 Pass W-020416 2/4/2016 Gr. Beta 29.7 +/- 0.3 28.9 17.3 -40.4 Pass W-021716 2/17/2016 Ra-226 17.9 +/- 0.5 16.7 10.0 - 23.4 Pass W-030716 3/7/2016 Gr.Alpha 16.3 +/- 0.8 20.1 12.0 - 28.1 Pass W-030716 3/7/2016 Gr. Beta 27.0 +/- 0.7 28.9 17.3 - 40.4 Pass SPDW-70046 3/29/2016 Ra-226 13.4+/-0.4 16.7 10.0 - 23.4 Pass SPW-1163 3/22/2016 Ra-228 4.2 +/- 0.7 4.4 2.6 - 6.2 Pass SPW-1235 3/29/2016 Gr. Alpha 21.0 +/- 0.4 20.1 12.0 - 28.1 Pass SPW-1235 3/29/2016 Gr. Beta 29.4 +/- 0.3 28.9 17.3 -40.4 Pass SPW-1739 4/21/2016 Ra-228 16.2 +/- 2.0 17.7 10.6 - 24.8 Pass SPW-2052 4/21/2016 Ra-226 16.0 +/- 0.5 16.7 10.0 - 23.4 Pass W-042616 4/21/2016 Fe-55 1,519+/-61 1,482 889 - 2,075 Pass SPW-1823 4/23/2016 Gr. Alpha 21.0 +/- 0.4 20.1 12.0 - 28.1 Pass SPW-1823 4/23/2016 Gr. Beta 26.6 +/- 0.3 28.9 17.3 -40.4 Pass SPW-1998 4/29/2016 Cs-134 35.9 +/- 6.0 36.2 21.7 - 50.6 Pass SPW-1998 4/29/2016 Cs-137 82.5 +/- 7.6 71.9 43.1 -100.6 Pass SPW-2097 5/3/2016 H-3 3,349 +/- 184 3,280 1,968 - 4,592 Pass SPW-2132 5/4/2016 H-3 3,174 +/- 178 3,280 1,968 - 4,592 Pass SPW-2229 5n/2016 H-3 3,182 +/- 179 3,280 1,968 - 4,592 Pass SPW-2313 5/13/2016 H-3 3,183 +/- 179 3,280 1,968 - 4,592 Pass SPW-2341 5/13/2016 H-3 3,201 +/- 178 3,280 1,968 - 4,592 Pass SPW-2374 5/14/2016 H-3 3,037 +/- 175 3,280 1,968 - 4,592 Pass SPW-2411 5/17/2016 Sr-90 37.3+/-1.6 37.3 22.4 - 52.2 Pass SPW-2455 5/19/2016 Gr. Alpha 19.3 +/- 0.4 20.1 12.0 -28.1 Pass SPW-2455 5/19/2016 Gr. Beta 28.6 +/- 0.3 28.9 17.3 - 40.4 Pass SPW-2457 5/19/2016 U-238 48.2 +/- 2.4 41.7 25.0 - 58.4 Pass SPW-2504 5/20/2016 H-3 3,181 +/- 178 3,280 1,968 - 4,592 Pass SPW-2528 5/23/2016 H-3 2,998 +/- 175 3,280 1,968 - 4,592 Pass SPW-2566 5/24/2016 Gr. Alpha 19.8 +/- 0.5 20.1 12.0 -28.1 Pass SPW-2566 5/24/2016 Gr. Beta 30.4 +/- 0.3 28.9 17.3-40.4 Pass W-053116 4/29/2016 Cs-134 34.0 +/- 5.0 36.2 21.7 - 50.6 Pass W-053116 4/29/2016 Cs-137 78.8 +/- 7.0 71.9 43.1 -100.6 Pass SPW-2704 6/1/2016 Sr-90 38.0 +/- 1.6 37.3 22.4 - 52.2 Pass SPW-2719 6/2/2016 Ra-228 18.1 +/- 2.1 17.7 10.6 - 24.8 Pass SPW-2749 6/3/2016 H-3 3,197 +/- 180 3,280 1,968 - 4,592 Pass SPW-2843 6/7/2016 H-3 3,133 +/- 179 3,280 1,968 - 4,592 Pass SPW-3227 6/17/2016 Ra-226 18.6+/-0.4 16.7 10.0 - 23.4 Pass W-061716 4/29/2016 Cs-134 37.3 +/- 8.2 36.2 21.7 - 50.6 Pass W-061716 4/29/2016 Cs-137 79.7 +/- 10.8 71.9 43.1 -100.6 Pass SPW-3240 6/28/2016 Gr. Alpha 25.3 +/- 0.5 20.1 12.0 - 28.1 Pass SPW-3240 6/28/2016 Gr. Beta 27.1 +/- 0.3 28.9 17.3 -40.4 Pass A3-1

TABLE A-3. In-House "Spiked" Samples Concentration a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limits d Acceptance SPW-3241 7/1/2016 H-3 8,821 +/- 283 8,650 5,190 -12,110 Pass SPW-3309 711/2016 H-3 8,619 +/- 278 8,650 5,190 -12,110 Pass SPW-3313 7/1/2016 Ra-228 16.6 +/- 2.0 17.7 10.6 -24.8 Pass SPW-3328 7/6/2016 Sr-89 13.4 +/- 9.2 14.8 8.9 - 20.7 Pass SPW-3328 7/6/2016 Sr-90 12.3+/-1.3 11.4 6.8 - 16.0 Pass SPAP-3365 717/2016 Gr. Beta 39.7 +/- 0.1 42.2 25.3 - 59.0 Pass SPAP-3367 717/2016 Cs-134 1.2 +/- 0.7 1.2 0.7 - 1.7 Pass SPAP-3367 7/7/2016 Cs-137 94.4 +/- 2.8 94.0 56.4-131.6 Pass SPW-3370 7/7/2016 C-14 4,444 +/- 17 4,735 2,841 - 6,629 Pass SPW-3373 7/7/2016 Ni-63 446 +/- 5 401 241 - 561 Pass SPW-3375 7/7/2016 Tc-99 545 +/- 9 539 324 - 755 Pass SPW-3519 7/14/2016 H-3 8,621 +/- 279 8650 5,190 -12,110 Pass SPW-3688 6/29/2016 Ra-226 17.5 +/- 0.4 16.7 10.0 - 23.4 Pass SPW-3711 7/20/2016 H-3 44,368 +/- 612 43,766 26,260 - 61,273 Pass SPW-3774 7/22/2016 H-3 45,259 +/- 619 43,766 26,260 -*61,273 Pass SPW-3776 7/22/2016 Gr. Alpha 23.3 +/- 0.5 20.1 12.0 - 28.1 Pass SPW-3776 7/22/2016 Gr. Beta 27.5 +/- 0.3 28.9 17.3 - 40.4 Pass SPW-3884 7/26/2016 H-3 45,850 +/- 623 43,766 26,260 - 61,273 Pass SPW-3950 7/28/2016 Ra-228 17.8+/-1.8 16.7 10 - 23 Pass SPW-3982 7/29/2016 H-3 45,273 +/- 619 43,766 26,260 - 61,273 Pass W-073016 4/29/2016 Cs-134 36.5 +/- 6.1 36.2 21.7 - 50.6 Pass W-073016 4/29/2016 Cs-137 80.6 +/- 7.5 71.9 43.1 -100.6 Pass SPW-4134 8/4/2016 Ra-228 5.5 +/- 0.8 6.7 4.0 - 9.3 Pass SPW-4340 8/17/2016 Ra-228 19.9 +/- 2.0 16.7 10.0 - 23.4 Pass SPW-4386 7/15/2016 Ra-226 18.0 +/- 0.4 16.7 10.0 - 23.4 Pass W-082716 4/29/2016 Ra-228 32.5 +/- 5.2 36.2 21.7 -50.6 Pass W-082716 4/29/2016 Ra-226 78.5 +/- 8.3 71.9 43.1 - 100.6 Pass SPW-4642 9/6/2016 U-238 45.8 +/- 2.5 41.7 25.0 - 58.4 Pass SPW-4999 9/26/2016 Sr-90 35.1 +/- 2.2 36.8 22.1 -51.5 Pass SPW-5091 9/12/2016 Ra-226 18.2 +/- 0.4 16.7 10.0 - 23.4 Pass W-092716 4/29/2016 Cs-134 37.3+/-11.8 36.2 21.7 - 50.6 Pass W-092716 4/29/2016 Cs-137 78.3+/-11.2 71.9 43.1 -100.6 Pass SPW-5165 9/30/2016 Gr. Alpha 22.2 +/- 0.4 20.1 12.0 - 28.1 Pass SPW-5165 9/30/2016 Gr. Beta 27.2 +/- 0.3 28.9 17.3 - 40.4 Pass SPW-5426 9/28/2016 Ra-226 18.2 +/- 0.4 16.7 10.0 - 23.4 Pass SPW-5510 10/18/2016 H-3 44,398 +/- 618 43,766 26,260 - 61273 Pass SPW-5553 10/19/2016 U-238 50.0 +/- 2.6 41.7 25.0 - 58.4 Pass SPW-5555 10/19/2016 Ra-228 17.4+/-1.9 16.7 10.0 - 23.4 Pass SPW-5612 10/20/2016 H-3 44,681 +/- 622 43,766 26,260 - 61,273 Pass SPW-5741 10/25/2016 H-3 44,946 +/- 624 43,766 26,260 - 61,273 Pass SPU-5833 10/26/2016 H-3 10,018 +/-946 8,622 5,173 -12,071 Pass SPW-5862 10/28/2016 H-3 18,061 +/- 374 17,244 10,346 - 24,141 Pass W-103116 4/29/2016 Cs-134 36.0 +/-4.6 36.2 21.7 - 50.6 Pass W-103116 4/29/2016 Cs-137 81.1 +/- 7.3 71.9 43.1 -100.6 Pass A3-2

TABLE A-3. In-House "Spiked" Samples Concentration a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 ° Activity Limits d Acceptance SPW-5984 11/2/2016 H-3 17,727 +/- 399 17,244 10,346 - 24, 141 Pass SPW-6008 11/4/2016 H-3 17,854 +/-402 17,244 10,346 -24,141 Pass SPW-6124 11/8/2016 Ra-228 14.4+/-1.9 16.0 9.6 - 22.4 Pass SPW-6132 11/9/2016 H-3 18,135 +/-374 17,243 10,346 - 24,140 Pass SPW-6135 10/12/2016 Ra-226 18.9 +/- 0.4 16.7 10.0 - 23.4 Pass SPW-6146 11/10/2016 H-3 17,488 +/- 398 17,243 10,346 - 24,140 Pass SPW-6222 11/12/2016 H-3 17,787 +/-408 17,243 10,346 - 24,140 Pass SPW-6318 11/16/2016 H-3 17,379 +/-408 17,243 10,346 - 24,140 Pass SPW-6349 11/17/2016 H-3 17,893 +/- 371 17,243 10,346 - 24,140 Pass SPW-6424 11/19/2016 H-3 18,258 +/- 379 17,243 10,346 - 24,140 Pass W-112616 4/29/2016 Cs-134 35.0 +/-6.0 36.2 21.7 - 50.6 Pass W-112616 4/29/2016 Cs-137 75.0 +/- 7.1 71.9 43.1 - 100.6 Pass SPW-6456 11/28/2016 Sr-90 41.9+/-2.5 36.8 22.1 - 51.5 Pass SPW-6486 11/30/2016 Sr-90 35.6 +/-2.2 36.6 21.9-51.2 Pass SPW-6490 11/29/2016 Ra-226 18.8 +/- 0.4 16.7 10.0 - 23.4 Pass SPW-6519 11/30/2016 Ni-63 438 +/-4 400 240 - 560 Pass SPW-6527 12/1/2016 U-238 49.5 +/- 2.5 41.7 25.0 - 58.4 Pass SPW-6616 12/3/2016 H-3 18,018 +/- 374 17,243 10,346 - 24,140 Pass SPW-6669 12/5/2016 H-3 18,237 +/- 377 17,243 10,346 - 24,140 Pass SPW-6735 12/9/2016 H-3 17,939 +/- 396 17,243 10,346 - 24,140 Pass SPW-6880 12/21/2016 H-3 17,835 +/- 396 17,243 10,346 - 24,140 Pass SPW-6947 12/22/2016 Ni-63 450 +/-4 400 240 - 560 Pass W-122316 4/29/2016 Cs-134 36.0 +/-2.2 36.2 21.7 -50.6 Pass W-122316 4/29/2016 Cs-134 76.1 +/-2.9 71.9 43.1 - 100.6 Pass SPW-6948 12/30/2016 H-3 17,999 +/- 398 17,243 10,346 - 24,140 Pass SPW-6974 12/29/2016 Ra-226 17.6 +/- 0.4 16.7 10.0 - 23.4 Pass

  • Liquid sample results are reported in pCi/Liter, air filters ( pCi/m3), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).

b Laboratory codes: W (Water), Ml (milk), AP (air filter), SO (soil), VE (vegetation), CH (charcoal canister), F (fish), U (urine).

0 Results are based on single determinations.

d Control limits are established from the precision values listed in Attachment A of this report, adjusted to+/- 2s.

NOTE: For fish, gelatin is used for the spike matrix. For vegetation, cabbage is used for the spike matrix.

A3-3

TABLE A-4. In-House "Blank" Samples Lab Code SPW-289*

SPW-291 SPW-293 SPW-413 W-020416 W-020416 W-020916 W-030716 W-030716 Sample Type Water Water Water Water Water Water Water Water Water SPDW-70045 Water SPDW-1234 Water SPDW-1234 Water SPW-1738 SPW-1822 SPW-1822 SPW-2051 SPW-2069 SPW-2133 SPW-2230 SPW-2314 SPW-2342 SPW-2364 SPW-2375 SPW-2410 SPW-2454 SPW-2454 SPW-2456 SPW-2485 SPW-2505 SPW-2529 SPW-2530 SPW-2565 SPW-2565 SPW-2703 SPW-2703 SPW-2718 SPW-2720 SPW-2750 SPW-2844 SPMl-2959 SPW-3137 SPW-3226 SPW-3239 SPW-~239 SPW-3687 Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Milk Water Water Water Water Water Date 1/21/2016 1/21/2016 1/21/2016 2/1/2016 2/4/2016 2/4/2016 2/9/2016 317/2016 317/2016 3/29/2016 3/30/2016 3/30/2016 4/21/2016 4/23/2016 4/23/2016 4/12/2016 5/3/2016 5/4/2016 517/2016 5/13/2016 5/13/2016 5/13/2016 5/14/2016 5/17/2016 5/19/2016 5/19/2016 5/19/2016 5/20/2916 5/20/2016 5/23/2016 5/23/2016 5/24/2016 5/24/2016 6/1/2016 6/1/2016 6/2/2016 6/2/2.016 6/3/2016 617/2016 6/14/2016 6/23/2016 6/17/2016 6/28/2016 6/28/2016 6/29/2016 Analysisb Sr-90 Sr-90 C-14 Ra-228 Gr. Alpha Gr. Beta Ra-226 Gr. Alpha Gr. Beta Ra-226 Gr. Alpha Gr. Beta Ra-228 Gr. Alpha Gr. Beta Ra-226 1-131 H-3 H-3 H-3 H-3 1-131 H-3 Sr-90 Gr. Alpha Gr. Beta U-238 1-131 H-3 H-3 Ra-228 Gr. Alpha Gr. Beta Sr-89 Sr-90 Ra-228 1-131 H-3 H-3 1-131 1-131 Ra-226 Gr. Alpha Gr. Beta Ra-226 Concentration a Laboratory results (4.66cr)

LLD Activity 0

0.55 0.61 147 0.86 0.43 0.73 0.02 0.90 1.59 0.03 0.44 0.79 1.05 0.50 0.08 0.02 0.15 148 149 150 143 0.22 146 0.59 0.47 0.77 0.15 0.18 144 152 0.96 0.47 0.77 0.68 0.55 0.67 0.16 151 148 0.16 0.15 0.02 0.40 0.73 0.04 0.28 +/-0.29 0.15+/-0.30

-12 +/- 89 1.86 +/- 0.60

-0.17 +/- 0.28 0.36 +/- 0.53 0.01 +/- 0.01

-0.36 +/- 0.32

-0.62 +/- 0.71 0.01 +/- 0.02

-0.05 +/- 0.30

-0.54 +/- 0.54 0.13 +/-0.50

-0.18 +/- 0.33

-0.35 +/- 0.51 0.03 +/- 0.02 0.06 +/- 0.09 55 +/-76

-11 +/- 73

-29 +/-72 50 +/-74

-0.03 +/- 0.12 1 +/-70 0.10+/-0.29

-0.21 +/- 0.31

-0.49 +/- 0.52 0.00 +/- 0.09

-0.01 +/- 0.10 64 +/-75

-3 +/- 75

-0.12 +/- 0.43 0.03 +/- 0.33

-0.23 +/- 0.53

-0.13 +/- 0.50 0.11 +/- 0.27 0.23 +/- 0.34 0.01 +/- 0.09

-31 +/- 73

-55 +/- 75 0.09 +/-0.10

-0.03 +/- 0.08

-0.01 +/- 0.04

-0.15+/-0.26 0.14 +/- 0.52 0.03 +/- 0.03 Acceptance Criteria (4.66 cr) 200 2

2 4

2 2

4 2

2 4

2 2

4 2

200 200 200 200 1

200 1

2 4

1 200 200 2

2 4

5 2

200 200 1

2 2

4 2

  • Liquid sample results are reported in pCi/Liter, air filters ( pCUm3), charcoal (pCi/charcoal canister), and solid samples (pCi/g).
  • l-131(G); iodine-131 as analyzed by gamma spectroscopy.

0 Activity reported is a net activity result.

A4-1

TABLE A-4. In-House "Blank" Samples Lab Code SPW-3312 SPW-3327 SPW-3327 SPAP-3364 SPW-3370 SPW-3372 SPW-3374 SPW-3710 SPW-3775 SPW-3775 SPW-3884 SPW-3949 SPW-3982 SPW-4133 SPW-4257 SPW-4339 SPW-4385 SPW-4641 SPW-4684 SPW-4872 SPW-4998 SPW-4998 SPW-5090 SPW-5164 SPW-5164 SPW-5425 SPW-5323 SPW-5552 SPW-5554 SPW-5611 SPW-5613 SPW-5613 SPW-5740 SPW-5743 SPW-5861 SPW-5983 SPW-6007 SPW-6131 SPW-6134 SPW-6145 SPW-6317 SPW-6348 SPW-6423 SPW-6455 SPW-6455 SPW-6489 Sample Type Water Water Water AP Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Water Date 7/1/2016 7/6/2016 7/6/2016 717/2016 7/7/2016 7/7/2016 717/2016 7/20/2016 7/22/2016 7/22/2016 7/26/2016 7/28/2016 7/29/2016 8/4/2016 8/11/2016 8/17/2016 7/15/2016 9/6/2016 9/8/2016 9/16/2016 9/26/2016 9/26/2016 8/19/2016 9/30/2016 9/30/2016 9/28/2016 10/7/2016 10/19/2016 10/19/2016 10/20/2016 10/21/2016 10/21/2016 10/25/2016 10/25/2016 10/28/2016 11/2/2016 11/4/2016 11/9/2016 10/12/2016 11/10/2016 11/16/2016 11/17/2016 11/19/2016 11/28/2016 11/28/2016 11/29/2016 Analysisb Ra-228 Sr-89 Sr-90 Gr.Beta C-14 Ni-63 Tc-99 H-3 Gr. Alpha Gr. Beta H-3 Ra-228 H-3 Ra-228 1-131 Ra-228 Ra-226 U-238 H-3 1-131 Sr-89 Sr-90 Ra-226 Gr. Alpha Gr. Beta Ra-226 H-3 U-238 Ra-228 H-3 Gr. Alpha Gr. Beta H-3 Sr-90 H-3 H-3 H-3 H-3 Ra-226 H-3 H-3 H-3 H-3 Sr-89 Sr-90 Ra-226 Concentration a Laboratory results (4.66cr)

LLD Activity 0

0.67 0.67 0.60 0.002 115 122 6.07 147 0.73 0.45 151 0.76 145 0.80 0.17 0.73 0.09 0.21 151 0.21 0.54 0.53 0.03 0.46 0.74 0.02 157 0.18 0.72 153 0.76 0.42 154 1.26 179 156 156 180 0.05 171 180 182 181 0.58 0.67 0.03 0.35 +/- 0.35 0.51 +/- 0.51

-0.14 +/- 0.26 0.005 +/- 0.001 49 +/-71 115 +/- 76 1.00 +/- 3.70 35 +/-75 0.41 +/- 0.53

-0.14 +/- 0.30

-1 +/- 73 0.32 +/- 0.39 49 +/-75 0.26 +/- 0.40

-0.01 +/- 0.10 0.36 +/- 0.39 0.75 +/- 0.09 0.00 +/- 0.13 48 +/-78 0.05 +/- 0.11 0.06 +/- 0.39

-0.03 +/- 0.24 0.03 +/- 0.02

-0.05 +/- 0.32

-0.02 +/- 0.52 0.07 +/- 0.05

-12 +/- 75 0.00 +/- 0.11 0.22+/- 0.36 67 +/-80

-0.55 +/- 0.51 0.02 +/- 0.29

-2 +/-72 0.72 +/- 0.67 129 +/- 91 8 +/-78

-34 +/- 73 80 +/- 92

-0.02 +/- 0.12

-46 +/- 80

-43 +/- 82

-45 +/- 88 8 +/-95

-0.15 +/-0.46 0.09 +/- 0.32 0.03 +/- 0.02 Acceptance Criteria (4.66 cr) 2 5

1 0.01 200 200 10 200 2

4 200 2

200 2

1 2

2 200 1

5 2

2 4

2 200 2

200 2

4 200 1

200 200 200 200 2

200 200 200 200 5

2

' Liquid sample results are reported in pCi/Liter, air filters ( pCiim\\ charcoal (pCi/charcoal canister), and solid samples (pCi/g).

b l-131(G); iodine-131 as analyzed by gamma spectroscopy.

0 Activity reported is a net activity result.

A4-2

I TABLE A-4. In-House "Blank" Samples Concentration a Lab Code Sample Date Analysisb Laboratory results (4.66cr)

Acceptance Type LLD Activity° Criteria (4.66 cr)

SPW-6529 Water 12/1/2016 1-131 0.18

-0.03 +/- 0.10 SPW-6616 Water 12/3/2016 H-3 180 72 +/- 92 200 SPW-6670 Water 12/5/2016 H-3 174 28 +/- 92 200 SPW-6735 Water 12/9/2016 H-3 152 2 +/- 73 200 SPW-6792 Water 12/15/2016 1-131 0.17 0.03 +/- 0.12 1

SPW-6819 Water 12/16/2016 H-3 158 14 +/-77 200 SPW-6879 Water 12/21/2016 H-3 147 80 +/- 75 200 SPW-6947 Water 12/22/2016 Ni-63 93 26 +/-57 200 SPW-6973 Water 12/29/2016 Ra-226 0.03 0.03 +/- 0.02 2

a Liquid sample results are reported in pCi/Liter, air filters ( pCi/m 3), charcoal (pCi/charcoal canister), and solid samples (pCi/g).

b l-131(G); iodine-131 as analyzed by gamma spectroscopy.

0 Activity reported is a net activity result.

A4-3

TABLE A-5. In-House "Duplicate" Samples Lab Code AP-010416 SPS-62, 63 WW-125, 126 SPS-199, 200 SPS-199, 200 AP-011116 AP-011216 WW-262, 263 WW-346, 347 WW-283, 284 AP-011916 AP-012016 AP-020116 SWU-472, 473 SG-493, 494 SG-493, 494 SG-493, 494 AP-020816 AP-020916 SPS-619, 620 WW-640, 641 AP-021916 WW-822, 823 DW-70010, 70011 DW-70010, 70011 SW-934, 935 SPS-913, 914 SPS-913, 914 SPS-913, 914 SPS-913, 914 AP-030716 F-1303, 1304 SG-976, 977 SG-976, 977 Date 1/4/2016 1/7/2016 117/2016 1/7/2016 117/2016 1/11/2016 1/12/2016 1/14/2016 1/14/2016 1/18/2016 1/19/2016 1/20/2016 2/1/2016 2/2/2016 2/6/2016 2/6/2016 2/6/2016 2/8/2016 2/9/2016 2/18/2016 2/18/2016 2/19/2016 2/26/2016 2/29/2016 2/29/2016 3/1/2016 3/3/2016 3/3/2016 3/3/2016 3/3/2016 317/2016 3/7/2016 3/8/2016 3/8/2016 PM-1094, 1095 3/9/2016 Ml-1042, 1043 317/2016 DW-70023, 70024 317/2016 DW-70023, 70024 317/2016 DW-70014, 70015 3/7/2016 DW-70026, 70027 317/2016 DW-70038, 70039 3/8/2016 DW-70035, 70036 3/8/2016 DW-70035, 70036 3/8/2016 AP-031516 3/15/2016 AP-032116 AP-1218,1219 AP-1719, 1720 AP-033016 SPS-1260, 1261 XW-1467, 1468 XWW-1530, 1531 AP-1827, 1828 AP-1323, 1324 LW-1446,1447 3/21/2016 3/24/2016 3/28/2016 3/30/2016 3/30/2016 3/30/2016 3/30/2016 3/30/2016 3/31/2016 3/31/2016 Analysis Gr. Beta K-40 H-3 Cs-137 K-40 Gr. Beta Gr. Beta H-3 H-3 H-3 Gr. Beta Gr. Beta Gr. Beta Gr. Beta Ac-228 K-40 Pb-214 Gr. Beta Be-7 K-40 H-3 Gr. Beta H-3 Ra-226 Ra-228 Gr. Beta Cs-137 K-40 Ra-226 Ra-228 Gr. Beta K-40 Ra-226 Ra-228 K-40 K-40 Ra-226 Ra-228 Gr. Alpha Gr. Alpha Gr. Alpha Ra-226 Ra-228 Gr. Beta Gr. Beta Be-7 Be-7 Gr. Beta K-40 H-3 H-3 Be-7 Be-7 Gr. Beta First Result 0.044 +/- 0.006 21.1 +/- 1.9 659+/-102 0.09 +/- 0.02 7.60 +/- 0.60 0.024 +/- 0.005 0.030 +/- 0.004 153 +/- 78 1,036+/-117 437 +/- 92 0.042 +/- 0.005 0.023 +/- 0.003 0.023 +/- 0.005 4.37 +/- 0.47 2.10 +/- 0.20 5.79 +/- 0.57 1.84 +/- 0.11 0.020 +/- 0.004 0.032 +/- 0.005 20.0 +/- 1.8 90.1 +/- 75.0 0.021 +/- 0.003 2,770 +/- 173 4.88 +/- 0.29 3.00 +/- 0.77 0.94 +/- 0.52 0.08 +/- 0.03 17.45 +/- 0.94 1.02 +/- 0.08 1.09 +/-0.15 0.018 +/- 0.005 3.320 +/- 0.475 6.75 +/- 0.25 9.21 +/- 0.49 14.01 +/- 0.68 1,684 +/- 124 3.40 +/- 0.43 4.46 +/- 0.83 13.38 +/- 1.58 3.46 +/- 0.79 1.14 +/-0.89 0.47 +/- 0.10 0.56 +/- 0.45 0.014 +/- 0.003 0.014 +/- 0.004 0.135 +/- 0.065 0.075 +/- 0.008 0.023 +/- 0.004 18.00 +/- 1.92 310 +/- 87 198 +/- 84 0.069 +/- 0.011 0.206 +/- 0.120 2.36 +/- 0.93 AS-1 Concentration a Second Result 0.051 +/- 0.006 21.2+/-2.1 748 +/- 106 0.08 +/- 0.03 8.62 +/- 0.62 0.027 +/- 0.005 0.034 +/- 0.004 141 +/- 78 959+/-115 427 +/- 91 0.037 +/- 0.004 0.030 +/- 0.004 0.023 +/- 0.005 4.60 +/- 0.49 2.13 +/- 0.20 5.50 +/- 0.69 1.91 +/- 0.11 0.019 +/- 0.004 0.041 +/- 0.006 19.1+/-1.6 153.6 +/- 78.4 0.025 +/- 0.004 2,974 +/- 178 4.93 +/- 0.28 1.90 +/- 0.62 1.36 +/- 0.60 0.10 +/- 0.03 16.83 +/- 0.95 1.13 +/-0.17 1.13 +/-0.17 0.021 +/- 0.005 3.508 +/- 0.396 6.28 +/- 0.22 9.09 +/- 0.49 14.47 +/- 0.72 1,804+/-119 2.68 +/- 0.35 5.74 +/- 0.94 11.40 +/- 1.43 3.08 +/- 0.74 1.73 +/- 0.95 0.45 +/- 0.09 0.47 +/- 0.44 0.016 +/- 0.004 0.020 +/- 0.004 0.167 +/- 0.081 0.076 +/- 0.007 0.025 +/- 0.004 19.67+/-1.77 295 +/- 86 162 +/- 82 0.072 +/- 0.011 0.197 +/- 0.091 2.23 +/- 1.01 Averaged Result 0.047 +/- 0.004 21.2 +/- 1.4 703 +/- 74 0.08 +/- 0.02 8.11 +/-0.43 0.026 +/- 0.003 0.032 +/- 0.003 147 +/- 55 997 +/- 82 432 +/- 65 0.040 +/- 0.003 0.027 +/- 0.002 0.023 +/- 0.004 4.49 +/- 0.34 2.12 +/-0.14 5.65 +/- 0.45 1.88 +/- 0.08 0.020 +/- 0.003 0.036 +/- 0.004 19.5 +/- 1.2 121.8 +/-54.2 0.023 +/- 0.002 2,872 +/- 124 4.91 +/- 0.20 2.45 +/- 0.49 1.15 +/- 0.40 0.09 +/- 0.02 17.14 +/-0.67 1.07 +/- 0.09 1.11 +/- 0.11 0.019 +/- 0.003 3.414 +/- 0.309 6.52 +/- 0.17 9.15 +/- 0.35 14.24 +/- 0.49 1,744 +/-86 3.04 +/- 0.28 5.10+/-0.63 12.39 +/- 1.07 3.27 +/- 0.54 1.44 +/- 0.65 0.46 +/- 0.07 0.52 +/- 0.31 0.015 +/- 0.002 0.017 +/- 0.003 0.151 +/- 0.052 0.076 +/- 0.005 0.024 +/- 0.003 18.84+/-1.30 303 +/- 61 180 +/- 59 0.071 +/- 0.008 0.202 +/- 0.076 2.29 +/- 0.69 Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

TABLE A-5. In-House "Duplicate" Samples Lab Code AP-010416 SPS-62, 63 WW-125, 126 SPS-199, 200 SPS-199, 200 AP-011116 AP-011216 WW-262, 263 WW-346, 347 WW-283, 284 AP-011916 AP-012016 AP-020116 SWU-472, 473 SG-493, 494 SG-493, 494 SG-493, 494 AP-020816 AP-020916 SPS-619, 620 WW-640, 641 AP-021916 WW-822; 823 DW-70010, 70011 DW-70010, 70011 SW-934, 935 SPS-913, 914 SPS-913, 914 SPS-913, 914 SPS-913, 914 AP-030716 F-1303, 1304 SG-976, 977 SG-976, 977 PM-1094, 1095 Ml-1042, 1043 Date 1/4/2016 117/2016 117/2016 117/2016 117/2016 1/11/2016 1/12/2016 1/14/2016 1/14/2016 1/18/2016 1/19/2016 1/20/2016 2/1/2016 2/2/2016 2/6/2016 2/6/2016 2/6/2016 2/8/2016 2/9/2016 2/18/2016 2/18/2016 2/19/2016 2/26/2016 2/29/2016 2/29/2016 3/1/2016 3/3/2016 3/3/2016 3/3/2016 3/3/2016 317/2016 317/2016 3/8/2016 3/8/2016 3/9/2016 317/2016 DW-70023, 70024 3/7/2016 DW-70023, 70024 317/2016 DW-70014, 70015 3/7/2016 DW-70026, 70027 317/2016 DW-70038, 70039 3/8/2016 DW-70035, 70036 3/8/2016 DW-70035, 70036 3/8/2016 AP-031516 AP-032116 AP-1218, 1219 3/15/2016 3/21/2016 3/24/2016 AP-1719, 1720 3/28/2016 AP-033016 3/30/2016 SPS-1260, 1261 3/30/2016 XW-1467, 1468 3/30/2016 XWW-1530, 1531 3/30/2016 AP-1827, 1828 3/30/2016 AP-1323,1324 3/31/2016 LW-1446,1447 3/31/2016 Analysis Gr. Beta K-40 H-3 Cs-137 K-40 Gr. Beta Gr. Beta H-3 H-3 H-3 Gr. Beta Gr. Beta Gr. Beta Gr. Beta Ac-228 K-40 Pb-214 Gr. Beta Be-7 K-40 H-3 Gr. Beta H-3 Ra-226 Ra-228 Gr. Beta Cs-137 K-40 Ra-226 Ra-228 Gr. Beta K-40 Ra-226 Ra-228 K-40 K-40 Ra-226 Ra-228 Gr.Alpha Gr. Alpha Gr. Alpha Ra-226 Ra-228 Gr. Beta Gr. Beta Be-7 Be-7 Gr. Beta K-40 H-3 H-3 Be-7 Be-7 Gr. Beta First Result 0.044 +/- 0.006 21.1 +/- 1.9 659 +/- 102 0.09 +/- 0.02 7.60 +/- 0.60 0.024 +/- 0.005 0.030 +/- 0.004 153 +/- 78 1,036+/-117 437 +/- 92 0.042 +/- 0.005 0.023 +/- 0.003 0.023 +/- 0.005 4.37 +/- 0.47 2.10 +/- 0.20 5.79 +/- 0.57 1.84 +/- 0.11 0.020 +/- 0.004 0.032 +/- 0.005 20.0 +/- 1.8 90.1 +/- 75.0 0.021 +/- 0.003 2,770 +/- 173 4.88 +/- 0.29 3.00 +/- 0.77 0.94 +/- 0.52 0.08 +/- 0.03 17.45 +/- 0.94 1.02 +/- 0.08 1.09 +/-0.15 0.018 +/- 0.005 3.320 +/- 0.475 6.75 +/- 0.25 9.21 +/- 0.49 14.01 +/- 0.68 1,684 +/- 124 3.40 +/- 0.43 4.46 +/- 0.83 13.38 +/- 1.58 3.46 +/- 0.79 1.14+/-0.89 0.47 +/-0.10 0.56 +/- 0.45 0.014 +/- 0.003 0.014 +/- 0.004 0.135 +/- 0.065 0.075 +/- 0.008 0.023 +/- 0.004 18.00 +/- 1.92 310 +/- 87 198 +/- 84 0.069 +/- 0.011 0.206 +/- 0.120 2.36 +/- 0.93 AS-2 Concentration a Second Result 0.051 +/- 0.006 21.2 +/- 2.1 748 +/- 106 0.08 +/- 0.03 8.62 +/- 0.62 0.027 +/- 0.005 0.034 +/- 0.004 141 +/- 78 959+/-115 427 +/- 91 0.037 +/- 0.004 0.030 +/- 0.004 0.023 +/- 0.005 4.60 +/- 0.49 2.13+/-0.20 5.50 +/- 0.69 1.91 +/- 0.11 0.019 +/- 0.004 0.04.1 +/- 0.006 19.1 +/- 1.6 153.6 +/- 78.4 0.025 +/- 0.004 2,974 +/- 178 4.93 +/- 0.28 1.90 +/- 0.62 1.36 +/- 0.60 0.10 +/- 0.03 16.83 +/- 0.95 1.13 +/- 0.17 1.13 +/- 0.17 0.021 +/- 0.005 3.508 +/- 0.396 6.28 +/- 0.22 9.09 +/- 0.49 14.47 +/- 0.72 1,804+/-119 2.68 +/- 0.35 5.74 +/- 0.94 11.40 +/- 1.43 3.08 +/- 0.74 1.73 +/- 0.95 0.45 +/- 0.09 0.47 +/- 0.44 0.016 +/- 0.004 0.020 +/- 0.004 0.167 +/- 0.081 0.076 +/- 0.007 0.025 +/- 0.004 19.67+/-1.77 295 +/- 86 162 +/- 82 0.072 +/- 0.011 0.197 +/- 0.091 2.23 +/- 1.01 Averaged Result 0.047 +/- 0.004 21.2 +/- 1.4 703 +/- 74 0.08 +/- 0.02 8.11 +/- 0.43 0.026 +/- 0.003 0.032 +/- 0.003 147 +/- 55 997 +/- 82 432 +/- 65 0.040 +/- 0.003 0.027 +/- 0.002 0.023 +/- O.OP4 4.49 +/- 0.34 2.12 +/- 0.14 5.65 +/- 0.45 1.88 +/- 0.08 0.020 +/- 0.003 0.036 +/- 0.004 19.5+/-1.2 121.8 +/- 54.2 0.023 +/- 0.002 2,872 +/- 124 4.91 +/- 0.20 2.45 +/- 0.49 1.15 +/-0.40 0.09 +/- 0.02 17.14 +/- 0.67 1.07 +/- 0.09 1.11 +/-0.11 0.019 +/- 0.003 3.414 +/- 0.309 6.52 +/- 0.17 9.15 +/- 0.35 14.24 +/- 0.49 1,744 +/- 86 3.04 +/- 0.28 5.10 +/-0.63 12.39 +/- 1.07 3.27 +/- 0.54 1.44 +/- 0.65 0.46 +/- 0.07 0.52 +/- 0.31 0.015 +/- 0.002 0.017 +/- 0.003 0.151 +/- 0.052 0.076 +/- 0.005 0.024 +/- 0.003 18.84+/-1.30 303 +/- 61 180 +/- 59 0.071 +/- 0.008 0.202 +/- 0.076 2.29 +/- 0.69 Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass I

4 4

4

TABLE A-5. In-House "Duplicate" Samples Lab Code WW-1740, 1741 SPS-1344, 1345 SPS-1344, 1345 SPS-1344, 1345 SPS-1344, 1345 P-1509, 1510 AP-041116 SS-1551, 1552 SS-1551, 1552 SS-1551, 1552 SS-1551,1552 SS-1551, 1552 SS-1551, 1552 SS-1551, 1552 SS-1593, 1594 WW-1677, 1678 WW-1783,1784 BS-1804, 1805 WW-2021,2022 XWW-2240, 2241 XWW-2109, 2110 SPS-2130, 2131 AP-042516 BS-2065, 2066 AP-042716 SPS-1999, 2000 S0-2153,2154 S0-2153,2154 S0-2153,2154 S0-2153,2154 W-2394,2395 VE-2284,2285 AP-051016 SG-2261, 2262 SG-2261, 2262 BS-2439, 2440 WW-2534,2535 AP-051716 SPS-2945, 2946 SPS-2945, 2946 SPS-2578, 2579 AP-052516 G-2642,2643 S0-2663, 2664 S0-2663, 2664 S0-2663, 2664 S0-2663, 2664 S0-2663, 2664 S0-2663, 2664 SPS-2817, 2818 DW-70091, 70092 DW-70091, 70092 BS-2925,2926 SPS-2796, 2797 SPS-2882, 2883 SPS-2882, 2883 DW-70102, 70103 Date 4/2/2016 4/4/2016 4/4/2016 4/4/2016 4/4/2016 4/8/2016 4/11/2016 4/12/2016 4/12/2016 4/12/2016 4/12/2016 4/12/2016 4/12/2016 4/12/2016 4/12/2016 4/14/2016 4/14/2016 4/18/2016 4/18/2016 4/18/2016 4/19/2016 4/25/2016 4/25/2016 4/25/2016 4/27/2016 4/28/2016 5/2/2016 5/2/2016 5/2/2016 5/2/2016 5/5/2016 5/9/2016 5/10/2016 5/10/2016 5/10/2016 5/12/2016 5/16/2016 5/17/2016 5/19/2016 5/19/2016 5/24/2016 5/25/2016 5/26/2016 5/26/2016 5/26/2016 5/26/2016 5/26/2016 5/26/2016 5/26/2016 5/31/2016 6/1/2016 6/1/2016 6/3/2016 6/2/2016 617/2016 617/2016 6/13/2016 Analysis H-3 K-40 Pb-214 Ac-228 Cs-137 H-3 Gr. Beta Gr. Beta K-40 Tl-208 Bi-214 Pb-212 Ra-226 Ac-228 K-40 Ra-226 H-3 K-40 H-3 H-3 H-3 K-40 Gr. Beta K-40 Gr. Beta K-40 K-40 Cs-137 Ra-226 Pb-214 H-3 K-40 Gr. Beta Ac-228 Pb-214 K-40 H-3 Gr. Beta K-40 Be-7 Pb-214 Gr. Beta Be-7 Cs-137 K-40 Tl-208 Pb-212 Ra-226 Ac-228 K-40 Ra-226 Ra-228 K-40 K-40 K-40 Be-7 Ra-226 First Result 21,162 +/- 120 17.98 +/- 0.93 1.12 +/-0.09 1.23 +/- 0.15 0.13 +/-0.03 1,084 +/- 120 0.020 +/- 0.004 8.71+/-1.11 3.50 +/- 0.25 0.05 +/- 0.02 0.10 +/- 0.02 0.13 +/-0.02 0.35 +/- 0.17 0.16 +/-0.05 14.80 +/- 0.73 0.23 +/- 0.13 768+/-111 0.79 +/- 0.02 5,548 +/- 221 638 +/- 104 3461 +/- 185 7.80 +/- 0.84 0.020 +/- 0.004 14.40 +/- 1.50 0.023 +/- 0.003 19.84 +/- 1.76 21.80 +/- 0.81 0.11 +/- 0.03 1.50 +/- 0.29 0.56 +/- 0.06 736 +/- 106 3.50 +/- 0.25 0.020 +/- 0.005 34.4+/-1.2 29.5 +/- 3.0 9.96 +/- 0.91 14,342 +/- 354 0.014 +/- 0.004 30.71 +/- 0.74 1.55 +/- 0.24 0.96 +/- 0.12 0.022 +/- 0.004 0.443 +/- 0.178 0.08 +/- 0.03 12.44 +/- 0.68 0.13 +/- 0.02 0.43 +/- 0.04 1.19 +/- 0.34 0.45 +/- 0.09 12.10 +/- 0.70 5.61 +/- 0.29 1.45 +/- 0.58 7.74 +/- 0.44 20.91 +/- 2.38 14.64 +/- 0.52 2.00 +/- 0.25 0.34 +/- 0.09 AS-3 Concentration a Second Result 21,091 +/- 427 17.14 +/- 0.96 1.04 +/- 0.08 1.33 +/- 0.19 0.13 +/- 0.03 1,038+/-119 0.019 +/- 0.004 8.88 +/- 1.13 3.06 +/- 0.28 0.05 +/- 0.02 0.09 +/- 0.02 0.11 +/- 0.02 0.30 +/- 0.17 0.17 +/- 0.05 14.89 +/- 0.78 0.35 +/- 0.15 632 +/- 107 0.87 +/- 0.19 5,707 +/- 224 543+/-101 3250 +/- 180 6.80 +/- 0.60 0.023 +/- 0.004 14.72+/-1.19 0.019 +/- 0.003 18.963 +/- 2.42 21.17 +/- 0.85 0.11 +/- 0.07 1.22 +/- 0.29 0.57 +/- 0.06 631 +/-102 3.06 +/- 0.28 0.018 +/- 0.005 34.4+/-1.4 31.9+/-3.3 10.27 +/- 0.76 14,613 +/- 357 0.015 +/- 0.004 31.75 +/- 0.78 1.90 +/- 0.35 0.80 +/- 0.14 0.022 +/- 0.004 0.247 +/- 0.247 0.07 +/- 0.03 11.64 +/- 0.63 0.14 +/- 0.03 0.41 +/- 0.04 0.87 +/- 0.28 0.53 +/-0.10 11.05 +/-0.70 5.53 +/- 0.30 1.91 +/- 0.62 7.86 +/- 0.42 21.16+/-1.82 14.60 +/- 0.52 1.94 +/- 0.20 0.36 +/- 0.08 Averaged Result 21,126 +/-222 17.56 +/- 0.67 1.08 +/- 0.06 1.28 +/- 0.12 0.13 +/-0.02 1,061 +/- 85 0.019 +/- 0.003 8.80 +/- 0.79 3.28+/-0.19 0.05 +/- 0.01 0.10 +/-0.02 0.12 +/- 0.01 0.32 +/-0.12 0.17 +/-0.04 14.85 +/- 0.53 0.29 +/-0.10 700 +/- 77 0.83 +/- 0.10 5,627 +/- 157 591 +/- 72 3356 +/- 129 7.30 +/- 0.52 0.022 +/- 0.003 14.56 +/- 0.96 0.021 +/- 0.002 19.40 +/-1.50 21.48 +/- 0.59 0.11 +/- 0.04 1.36 +/- 0.21 0.57 +/- 0.04 683 +/- 74 3.28 +/- 0.19 0.019 +/- 0.003 34.4 +/- 0.9 30.7 +/- 2.2 10.11 +/-0.59 14,477 +/- 252 0.014 +/- 0.003 31.23 +/- 0.54 1.73 +/- 0.21 0.88 +/- 0.09 0.022 +/- 0.003 0.345 +/- 0.152 0.07 +/- 0.02 12.04 +/- 0.46 0.14 +/- 0.02 0.42 +/- 0.03 1.03 +/- 0.22 0.49 +/- 0.07 11.58 +/- 0.49 5.57 +/- 0.21 1.68 +/- 0.42 7.80 +/- 0.30 21.04+/-1.50 14.62 +/- 0.37 1.97 +/- 0.16 0.35 +/- 0.06 Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

TABLE A-5. In-House "Duplicate" Samples Lab Code DW-70102, 70103 AP-061416 SG-3144, 3145 SG-3144, 3145 SPS-3165, 3166 SPS-3323, 3324 WW-3231, 3232 AP-3830,3831 AP-070516A AP-070516B XWW-3605,3606 DW-70135,70136 DW-70132,70133 DW-70132,70133 AP-071216 DW-70150,70151 SPS-3649,3650 SPS-3649,3650 SPS-3649,3650 SPS-3649,3650 AP-071816 DW-70163,70164 WW-3761,3762 SPS-4003,4004 AP-072516 VE-3936,3937 VE-3936,3937 VE-3936,3937 VE-3959,3960 VE-3959,3960 VE-3959,3960 DW-70169,70170 DW-70169,70170 AP-080116 SS-4131,4132 SS-4131,4132 SPS-4087,4088 WW-4976,4977 SPS-4266,4267 AP-081616 VE-4399,4400 VE-4399,4400 WW-5394,5395 SPS-4441,4442 AP-082216 VE-4462,4463 VE-4462,4463 WW-4594,4595 WW-4663,4664 SPS-4529,4530 AP-083016A AP-083016B VE-4615,4616 Date 6/13/2016 6/14/2016 6/17/2016 6/17/2016 6/22/2016 6/24/2016 6/27/2016 6/29/2016 7/5/2016 7/5/2016 717/2016 7/8/2016 7/8/2016 7/8/2016 7/12/2016 7/14/2016 7/15/2016 7/15/2016 7/15/2016 7/15/2016 7/18/2016 7/19/2016 7/20/2016 7/23/2016 7/25/2016 7/25/2016 7/25/2016 7/25/2016 7/27/2016 7/27/2016 7/27/2016 7/28/2016 7/28/2016 8/1/2016 8/1/2016 8/1/2016 8/2/2016 8/4/2016 8/10/2016 8/16/2016 8/18/2016 8/18/2016 8/18/2016 8/22/2016 8/22/2016 8/22/2016 8/22/2016 8/26/2016 8/26/2016 8/26/2016 8/30/2016 8/30/2016 8/31/2016 Analysis Ra-228 Gr. Beta Be-7 K-40 K-40 K-40 H-3 Gr. Beta Gr. Beta Gr. Beta H-3 Gr. Alpha Ra-226 Ra-228 Gr. Beta Gr. Alpha Cs-137 K-40 Pb-214 Ac-228 Gr. Beta Gr. Alpha H-3 K-40

.Gr. Beta Sr-90 Be-7 K-40 Sr-90 Be-7 K-40 Ra-226 Ra-228 Gr. Beta K-40 Cs-137 K-40 H-3 K-40 Gr. Beta K-40 Be-7 H-3 K-40 Gr. Beta Be-7 K-40 H-3 H-3 K-40 Gr. Beta Gr. Beta K-40 First Result 0.93 +/- 0.47 0.026 +/- 0.004 2.23 +/- 0.12 7.57 +/- 0.25 21.14 +/- 2.27 18.67 +/- 1.57 414 +/- 104 0.088 +/- 0.012 0.018 +/- 0.002 0.025 +/- 0.005 3,316 +/- 186 3.68 +/- 1.01 1.32 +/-0.14 3.92 +/- 0.94 0.014 +/- 0.004 5.00 +/- 1.06 0.12 +/- 0.03 16.68 +/- 0.79 1.20 +/- 0.08 1.28 +/- 0.16 0.022 +/- 0.005 1.08 +/- 0.66 347 +/- 90 7.15 +/- 1.59 0.023 +/- 0.004 0.048 +/- 0.007 0.49 +/-0.15 4.70 +/- 0.35 0.002 +/- 0.002 0.30 +/-0.14 4.01 +/- 0.37 0.83 +/- 0.11 1.85 +/- 0.63 0.029 +/- 0.003 12.47 +/- 0.71 0.10 +/- 0.03 17.06 +/- 1.58 17,043 +/- 390 1.06 +/- 0.47 0.029 +/- 0.005 3.85 +/- 0.23 0.30 +/- 0.08 947 +/- 122 20.55 +/- 2.23 0.021 +/- 0.005 0.91 +/- 0.09 7.48 +/- 0.26 675+/-107 607 +/- 104 21.98 +/- 2.52 0.030 +/- 0.003 0.032 +/- 0.009 2.96 +/-0.16 AS-4 Concentration "

Second Result 1.11 +/- 0.53 0.023 +/- 0.004 2.24 +/- 0.12 7.09 +/- 0.23 22.88 +/- 1.60 21.53 +/- 1.65 498 +/- 108 0.093 +/- 0.015 0.014 +/- 0.002 0.026 +/- 0.005 3,316 +/- 181 2.76 +/- 0.98 1.11 +/- 0.15 2.94 +/- 0.90 0.018 +/- 0.004 4.43 +/- 1.04 0.12 +/- 0.03 16.52 +/- 0.86 1.17 +/- 0.08 1.28 +/- 0.16 0.024 +/- 0.005 1.36 +/- 0.70 466 +/- 96 6.86 +/- 1.21 0.020 +/- 0.004 0.058 +/- 0.010 0.51 +/- 0.15 4.86 +/- 0.37 0.003 +/- 0.001 0.25 +/-0.12 4.16 +/-0.34 0.69 +/- 0.11 1.31 +/- 0.84 0.033 +/- 0.003 13.24 +/- 0.81 0.13+/-0.04 19.5+/-1.97 16,821 +/- 388 1.69 +/- 0.52 0.025 +/- 0.004 3.27 +/- 0.41 0.45 +/- 0.20 846+/-119 19.69 +/- 1.74 0.015 +/- 0.005 0.89 +/- 0.11 7.60 +/- 0.23 788 +/- 111 501 +/- 100 21.85 +/- 1.56 0.035 +/- 0.004 0.026 +/- 0.004 3.11 +/-b.17 Averaged Result 1.02 +/- 0.35 0.024 +/- 0.003 2.24 +/- 0.08 7.33 +/- 0.17 22.01 +/- 1.39 20.10 +/- 1.14 456 +/- 75 0.091 +/- 0.010 0.016 +/- 0.002 0.025 +/- 0.004 3,316 +/- 130 3.22 +/- 0.70 1.22 +/- 0.10 3.43 +/- 0.65 0.016 +/- 0.003 4.72 +/- 0.74 0.12 +/-0.02 16.6 +/- 0.58 1.19 +/- 0.06 1.28 +/- 0.11 0.023 +/- 0.003 1.22 +/- 0.48 407 +/- 66 7.00 +/- 1.00 0.022 +/- 0.003 0.053 +/- 0.006 0.50 +/-0.10 4.78 +/- 0.25 0.003 +/- 0.001 0.27 +/- 0.09 4.08 +/- 0.25 0.76 +/- 0.08 1.58 +/- 0.53 0.031 +/- 0.002 12.86 +/- 0.54 0.12 +/- 0.02 18.28+/-1.26 16,932 +/- 275 1.375 +/- 0.35 0.027 +/- 0.003 3.56 +/- 0.24 0.37 +/- 0.11 896 +/- 85 20.12+/-1.41 0.018 +/- 0.003 0.90 +/- 0.07 7.54 +/- 0.17 731 +/- 77 554 +/-72 21.92 +/- 1.48 0.033 +/- 0.002 0.029 +/- 0.005 3.03 +/- 0.11 Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

TABLE A-5. In-House "Duplicate" Samples Concentration a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance AP-110116 11/1/2016 Gr. Beta 0.021 +/- 0.004 0.024 +/- 0.004 0.023 +/- 0.003 Pass S-5963, 5964 11/1/2016 K-40 20.35 +/- 2.29 18.59 +/- 1.90 19.47+/-1.49 Pass SG-6119, 6120 11/1/2016 Ac-228 5.70 +/- 0.44 6.28 +/- 0.57 5.99 +/- 0.36 Pass SG-6119, 6120 11/1/2016 Gr. Alpha 21.59+/-1.88 24.35 +/- 1.93 22.97 +/- 1.35 Pass SG-6119, 6120 11/1/2016 K-40 4.89 +/- 1.10 5.90 +/- 1.08 5.40 +/- 0.77 Pass SG-6119, 6120 11/1/2016 Pb-214 3.99 +/- 0.21 4.35 +/- 0.32 4.17 +/- 0.19 Pass S-6051, 6052 11/4/2016 K-40 7.05 +/- 0.60 7.56 +/- 0.53 7.31 +/- 0.40 Pass WW-6297, 6298 11/8/2016 H-3 207 +/- 98 165 +/- 97 186 +/- 69 Pass WW-6341,6342 11/8/2016 H-3 1,356 +/- 140 1,404+/-141 1,380 +/- 99 Pass S0-6406,6407 11/9/2016 Cs-137 0.36 +/- 0.04 0.43 +/- 0.05 0.40 +/- 0.03 Pass S0-6406,6407 11/9/2016 K-40 10.90 +/- 0.68 11.29 +/- 0.74 11.09 +/-0.50 Pass AP-111416 11/14/2016 Gr. Beta 0.024 +/- 0.005 0.021 +/- 0.006 0.022 +/- 0.004 Pass WW-6829,6830 11/15/2016 H-3 39,982 +/- 589 40,315 +/- 591 40,149 +/-417 Pass DW-70239, 70240 11/17/2016 Gr. Alpha 7.99 +/- 1.15 6.41 +/- 1.05 7.20 +/- 0.78 Pass AP-112216 11/22/2016 Gr. Beta 0.049 +/- 0.005 0.045 +/- 0.005 0.047 +/- 0.003 Pass S-6473, 6474 11/24/2016 K-40 19.37 +/- 1.97 23.80 +/- 3.54 21.58 +/- 2.02 Pass SG-6938, 6939 11/28/2016 Ac-228 18.99 +/- 0.59 19.92 +/- 0.79 19.46 +/- 0.49 Pass SG-6938, 6939 11/28/2016 Pb-214 15.28 +/- 0.34 14.96 +/- 0.43 15.12 +/- 0.27 Pass AP-120116 12/1/2016 Gr. Beta 0.029 +/- 0.003 0.030 +/- 0.003 0.030 +/- 0.002 Pass F-6567,6568 12/1/2016 K-40 3.76 +/- 0.40 3.83 +/- 0.46 3.80 +/- 0.30 Pass S-6522,6523 12/1/2016 Ac-228 1.08 +/- 0.13 1.29 +/- 0.16 1.19+/-0.10 Pass S-6522, 6523 1211/2016 Pb-214 1.00 +/- 0.08 1.01 +/- 0.09 1.01 +/- 0.06 Pass S-6609, 6610 12/1/2016 K-40 15.57+/-1.01 15.99 +/- 0.78 15.78 +/- 0.64 Pass S-6718, 6719 12n/2016 K-40 18.19 +/- 2.13 18.76 +/- 1.80 18.48 +/- 1.39 Pass WW-6784, 6785 12/7/2016 H-3 922 +/- 117 905+/-116 914 +/- 82 Pass AP-121216 12/12/2016 Gr. Beta 0.026 +/- 0.005 0.028 +/- 0.005 0.027 +/- 0.003 Pass AP-7178,7179 1/3/2017 Be-7 0.047 +/- 0.015 0.062 +/- 0.017 0.054 +/- 0.012 Pass Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.

  • Results are reported in units of pCi/L, except for air filters (pCi/Filter or pCi/m3), food products, vegetation, soil and sediment (pCi/g).

A5-5

TABLEA-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration a Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance MAS0-1053 2/1/2016 Ni-63 1,206 +/- 20 1250 875 - 1625 Pass MAS0-1053 2/1/2016 Sr-90 0.65 +/- 1.27 0.00 NA c Pass MAS0-1053 2/1/2016 Tc-99 0.1 +/- 5:5 0.0 NA 0

Pass MAS0-1053 2/1/2016 Cs-134 908 +/- 26 1030 721 - 1339 Pass MAS0-1053 2/1/2016 Cs-137 0.10 +/- 6.20 0.00 NA 0

Pass MAS0-1053 2/1/2016 Co-57 1058 +/- 26 992 694 - 1290 Pass MAS0-1053 2/1/2016 Co-60 1229 +/-28 1190 833 - 1547 Pass MAS0-1053 2/1/2016 Mn-54 1235 +/- 43 1160 812 - 1508 Pass MAS0-1053 2/1/2016 Zn-65.

753 +/- 64 692 484 - 900 Pass MAS0-1053 2/1/2016 K-40 753+/-140 607 425 - 789 Pass MAS0-1053 2/1/2016 Am-241 79 +/-6 103 72 - 134 Pass MAS0-1053 2/1/2016 Pu-238 73.9 +/- 9.2 63.6 44.5 - 82.7 Pass MAS0-1053 2/1/2016 Pu-239/240 0.76+/-1.34 0.21 NAd Pass MAS0-1053 2/1/2016 U-234/233 45.0 +/- 5.1 45.9 32.1 - 59.7 Pass MAS0-1053 2/1/2016 U-238 129 +/- 9 146 102 - 190 Pass MAW-989 2/1/2016 Am-241 0.018 +/- 0.015 0.00 NA 0

Pass MAW-989 2/1/2016 H-3 0.2 +/- 2.8 0.0 NA 0

Pass MAW-989 2/1/2016 Ni-63 12.8 +/- 2.7 12.3 8:6 - 16.o Pass MAW-989 2/1/2016 Sr-90 8.70 +/- 1.20 8.74 6.12 - 11.36 Pass MAW-989 2/1/2016 Tc-99

-1.1 +/-0.6 0.0 NA 0

Pass MAW-989 2/1/2016 Cs-134 15.5 +/- 0.3 16.1 11.3 +/- 20.9 Pass MAW-989 2/1/2016 Cs-137 23.7 +/- 0.5 21.2 14.8 - 27.6 Pass MAW-989° 2/1/2016 Co-57 1.38+/-0.12 0.00 NA c Fail MAW-989 2/1/2016 Co-60 12.5 +/- 0.3 11.8 8.3 - 15.3 Pass MAW-989 2/1/2016 Mn-54 12.2 +/- 0.4 11.1 7.8 - 14.4 Pass MAW-989 2/1/2016 Zn-65 15.7 +/- 0.7 13.6 9.5 - 17.7 Pass MAW-989 2/1/2016 K-40 288 +/-5 251 176 - 326 Pass MAW-989 2/1/2016 Fe-55 17.3 +/- 7.0 16.2 11.3 -21.1 Pass MAW-989 2/1/2016 Ra-226 0.710 +/- 0.070 0.718 0.503 - 0.933 Pass MAW-989 2/1/2016 Pu-238 1.280 +/- 0.110 1.244 0.871 +/- 1.617 Pass MAW-989 2/1/2016 Pu-239/240 0.640 +/- 0.080 0.641 0.449 - 0.833 Pass MAW-989 2/1/2016 U-234/233 1.39 +/-0.12 1.48 1.04 - 1.92 Pass MAW-989 2/1/2016 U-238 1.43+/-0.12 1.53 1.07 - 1.99 Pass MAW-893 2/1/2016 Gross Alpha 0.600 +/- 0.050 0.673 0.202 -1.144 Pass MAW-893 2/1/2016 Gross Beta 2.10 +/- 0.06 2.15 1.08 - 3.23 Pass MAW-896 2/1/2016 1-129 3.67 +/- 0.20 3.85 2.70 - 5.01 Pass MAAP-1056 2/1/2016 Gross Alpha 0.39 +/- 0.05 1.20 0.36 -2.04 Pass MAAP-1056 2/1/2016 Gross Beta 1.03 +/- 0.07 0.79 0.40-1.19 Pass A6-1

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration a Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits 0

Acceptance MAAP-1057 2/1/2016 Sr-90 1.34 +/- 0.15 1.38 0.97+/-1.79 Pass MAAP-1057 2/1/2016 Cs-134

-0.01 +/- 0.03 0.00 NA 0

Pass MAAP-1057 2/1/2016 Cs-137 2.57 +/- 0.10 2.30 1.61 - 2.99 Pass MAAP-1057 2/1/2016 Co-57 3.01 +/- 0.06 2.94 2.06 - 3.82 Pass MAAP-1057 2/1/2016 Co-60 4.28 +/- 0.10 4.02 2.81 - 5.23 Pass MAAP-1057 2/1/2016 Mn-54 4.90 +/- 0.13 4.53 3.17-5.89 Pass MAAP-1057 2/1/2016 Zn-65 4.09 +/- 0.18 3.57 2.50 -4.64 Pass MAAP-1057 2/1/2016 Am-241 0.059 +/- 0.015 0.0805 0.0564 - 0.1047 Pass MAAP-1057 2/1/2016 Pu-238 0.066 +/- 0.020 0.0637 0.0446 - 0.0828 Pass MAAP-1057 2/1/2016 Pu-239/240 0.074 +/- 0.020 0.099 NA d Pass MAAP-1057 2/1/2016 U-234/233 0.151 +/- 0.026 0.165 0.116 -0.215 Pass MAAP-1057 2/1/2016 U-238 0.160.+/- 0.026 0.172 0.120 - 0.224 Pass MAVE-1050 2/1/2016 Cs-134 9.83 +/- 0.19 10.62 7.43 - 13.81 Pass MAVE-1050 2/1/2016 Cs-137 6.06 +/- 0.19 5.62 3.93 - 7.31 Pass MAVE-1050 2/1/2016 Co-57 13.8 +/- 0.2 11.8 8.3 -15.3 Pass MAVE-1050 2/1/2016 Co-60 0.022 +/- 0.040 0.00 NA 0

Pass MAVE-1050 2/1/2016 Mn-54 0.009 +/- 0.044 0.000 NA 0

Pass MAVE-1050 2/1/2016 Zn-65 10.67 +/- 0.39 9.60 6.70 - 12.50 Pass MAS0-47801 8/1/2016 Ni-63 648+/-14 990 693 - 1287 Fail MAS0-47809 8/1/2016 Ni-63 902 +/-46 990 693 -1287 Pass MAS0-4780 8/1/2016 Sr-90 757+/-16 894 626 - 1162 Pass MAS0-4780 8/1/2016 Tc-99 559 +/- 12 556 389 - 723 Pass MAS0-4780 8/1/2016 Cs-134 0.93 +/- 2.92 0.00 NA 0

Pass MAS0-4780 8/1/2016 Cs-137 1061 +/- 12 1067 747 - 1387 Pass MAS0-4780 8/1/2016 Co-57 1178 +/- 8 1190 833 - 1547 Pass MAS0-4780 8/1/2016 Co-60 841+/-9 851 596 -1106 Pass MAS0-4780 8/1/2016 Mn-54 0.69 +/- 2.53 0.00 NA 0

Pass MAS0-4780 8/1/2016 Zn-65 724 +/- 19 695 487 - 904 Pass MAS0-4780 8/1/2016 K-40 566 +/- 52 588 412 - 764 Pass MAS0-4780 8/1/2016 Am-241 0.494 +/- 0.698 0.000 NA 0

Pass MAS0-4780 8/1/2016 Pu-238 69.7 +/- 7.4 70.4 49.3 - 91.5 Pass MAS0-4780 8/1/2016 Pu-239/240 53.9 +/- 6.3 53.8 37.7 - 69.9 Pass MAS0-4780h 8/1/2016 U-233/234 46.8 +/- 3.9 122 85 - 159 Fail MAS0-4780h 8/1/2016 U-238 46.6 +/- 3.9 121 85 - 157 Fail MAW-4776 8/1/2016 1-129 4.40 +/- 0.20 4.54 3.18 - 5.90 Pass MAVE-4782 8/1/2016 Cs-134

-0.01 +/- 0.05 0.00 NA 0

Pass MAVE-4782 8/1/2016 Cs-137 6.18 +/- 0.20 5.54 3.88 - 7.20 Pass MAVE-4782 8/1/2016 Co-57 8.13 +/- 0.16 6.81 4.77 - 8.85 Pass MAVE-4782 8/1/2016 Co-60 5.30 +/- 0.15 4.86 3.40 - 6.32 Pass MAVE-4782 8/1/2016 Mn-54 8.08 +/- 0.24 7.27 5.09 - 9.45 Pass MAVE-4782 8/1/2016 Zn-65 6.24 +/- 0.36 5.40 3.78 - 7.02 Pass A6-2

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration a Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits 0

Acceptance MAAP-4784 8/1/2016 Sr-90 1.18 +/- 0.10 1.03 0.72 -1.34 Pass MAAP-4784 8/1/2016 Cs-134 1.58 +/- 0.08 2.04 1.43 - 2.65 Pass MAAP-4784 8/1/2016 Cs-137 1.85 +/- 0.09 1.78 1.25 - 2.31 Pass MAAP-4784 8/1/2016 Co-57 2.39 +/- 0.52 2.48 1.74 - 3.22 Pass MAAP-4784 8/1/2016 Co-60 3.22 +/- 0.08 3.26 2.28 -4.24 Pass MAAP-4784 8/1/2016 Mn-54 2.82 +/- 0.12 2.75 1.93 - 3.58 Pass MAAP-4784 8/1/2016 Zn-65

-0.015 +/- 0.062 0.00 NA c Pass MAAP-4784 8/1/2016 Am-241

-0.001 +/- 0.006 0.00 NA c Pass MAAP-4784 8/1/2016 Pu-238 0.075 +/- 0.022 0.069 0.049 - 0.090 Pass MAAP-4784 8/1/2016 Pu-239/240 0.048 +/- 0.015 0.054 0.038 - 0.070 Pass MAAP-4784 8/1/2016 U-234/233 0.151 +/- 0.036 0.150 0.105 - 0.195 Pass MAAP-4784 8/1/2016 U-238 0.147 +/- 0.034 0.156 0.109 - 0.203 Pass MAW-4778 8/1/2016 H-3 365 +/- 11 334 234 -434 Pass MAW-4778 8/1/2016 Fe-55 23.6 +/- 16.3 21.5 15.1 +/- 28.0 Pass MAW-4778 8/1/2016 Ni-63 17.0 +/- 2.8 17.2 12.0 +/- 22.4 Pass MAW-4778 8/1/2016 Sr-90 0.17 +/- 0.28 0.00 NA c Pass MAW-4778 8/1/2016 Tc-99 9.50 +/- 0.41 11.60 8.10 -15.10 Pass MAW-4778 8/1/2016 Cs-134 22.6 +/- 0.4 23.9 16.7-31.1 Pass MAW-4778 8/1/2016 Cs-137 0.018 +/- 0.117 0.00 NA 0

Pass MAW-4778 8/1/2016 Co-57 27.6 +/- 0.2 27.3 19.1 +/- 35.5 Pass MAW-4778 8/1/2016 Co-60 0.018 +/- 0.090 0.00 NA 0

Pass MAW-4778 8/1/2016 Mn-54 16.2 +/- 0.4 14.8 10.4 - 19.2 Pass MAW-4778 8/1/2016 Zn-65 19.3 +/- 0.7 17.4 12.2 -22.6 Pass MAW-4778 8/1/2016 K-40 286 +/- 6 252 176 - 328 Pass MAW-4778 8/1/2016 Ra-226 1.48 +/- 0.09 1.33 0.93 - 1.73 Pass MAW-4778 8/1/2016 Pu-238 1.09 +/- 0.13 1.13 0.79 - 1.47 Pass MAW-4778 8/1/2016 Pu-239/240 0.003 +/- 0.011 0.016 NA d Pass MAW-4778 8/1/2016 U-234/233 1.80+/-0.13 1.86 1.30 - 2.42 Pass MAW-4778 8/1/2016 U-238 1.77 +/- 0.13 1.92 1.34 - 2.50 Pass MAW-4778 8/1/2016 Am-241 0.678 +/- 0.086 0.814 0.570 +/- 1.058 Pass

  • Results are reported in units of Bq/kg (soil), Bq/L (water) or Sq/total sample (filters, vegetation).

b Laboratory codes as follows: MAW (water), MAAP (air filter), MASO (soil), MAVE (vegetation).

0 MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". MAPEP does not provide control limits.

d Provided in the series for "sensitivity evaluation". MAPEP does not provide control limits.

  • The laboratory properly identified the Sn-75 interfering peak in the vicinity of Co-57 and stated so in the comment field. MAPEP requires results to be reported as an activity with an uncertainty. Since the calculated uncertainty was less than the activity MAPEP interpreted the submitted result as a "false positive" resulting in a failure.

1 Original analysis for Ni-63 failed.

9 Reanalysis with a smaller aliquot resulted in acceptable results. An investigation is in process to identify better techniques for analyzing samples with complex matrices.

h MAPEP states that samples contain two fractions of Uranium; one that is soluble in concentrated HN03 and HCl acid and one that is "fundamentally insoluble in these acids". They also state that HF treatment can not assure complete dissolution.

Results are consistent with measuring the soluble form.

A6-3

TABLEA-7. lnterlaboratory Comparison Crosscheck Program, Environmental Resource Associates (ERA)*.

MRAD Study Concentration a Lab Code b Date Analysis Laboratory ERA Control Result Result Limits Acceptance ERAP-1101 3/14/2016 Am-241 37.3 45.9 28.3 - 62.1 Pass ERAP-1101 3/14/2016 Co-60 637 623 482 - 778 Pass ERAP-1101 3/14/2016 Cs-134 251 304 193 - 377 Pass ERAP-1101 3/14/2016 Cs-137 1,273 1,150 864 -1,510 Pass ERAP-1101 3/14/2016 Fe-55

< 162 126 39.1 -246 Pass ERAP-1101 3/14/2016 Mn-54

< 2.64

< 50.0 0.00 -50.0 Pass ERAP-1101 3/14/2016 Pu-238 68.0 70.5 48.3 -92.7 Pass ERAP-1101 3/14/2016 Pu-239/240 54.1 54.8 39.70 - 71.60 Pass ERAP-1101 3/14/2016 Sr-90 139 150 73.3 -225.0 Pass ERAP-1101 3/14/2016 U-233/234 59.3 64.8 40.2 - 97.7 Pass ERAP-1101 3/14/2016 U-238 55.5 64.2 41.5 - 88.8 Pass ERAP-1101 3/14/2016 Zn-65 428 356 255 -492 Pass ERAP-1101 3/14/2016 Gr. Alpha 98.0 70.1 23.5 - 109 Pass ERAP-1101 3/14/2016 Gr. Beta 78.6 54.4 34.4 - 79.3 Pass ERS0-1105 3/14/2016 Am-241 1,030 1,360 796 - 1,770 Pass ERS0-1105 3/14/2016 Ac-228 1,540 1,240 795 - 1,720 Pass ERS0-1105 3/14/2016 Bi-212 1,550 1,240 330 -1,820 Pass ERS0-1105 3/14/2016 Bi-214 3,100 3,530 2,130 - 5,080 Pass ERS0-1105 3/14/2016 Co-60 5,600 5,490 3,710 - 7,560 Pass ERS0-1105 3/14/2016 Cs-134 3,030 3,450 2,260 -4,140 Pass ERS0-1105 3/14/2016 Cs-137

_4,440 4,310 3,300 - 5,550 Pass ERS0-1105 3/14/2016 K-40 10,300 10,600 7,740 - 14,200 Pass ERS0-1105 3/14/2016 Mn-54

< 50.8

< 1000 0.0 - 1,000 Pass ERS0-1105 3/14/2016 Pb-212 1,140 1,240 812 - 1,730 Pass ERS0-1105 3/14/2016 Pb-214 3,190 3,710 2,170 - 5,530 Pass ERS0-1105 3/14/2016 Pu-238 680 658 396 - 908 Pass ERS0-1105 3/14/2016 Pu-239/240 460 496 324 -0,685 Pass ERS0-1105 3/14/2016 Sr-90 7,740 8,560 3,260 - 13,500 Pass ERS0-1105 3/14/2016 Th-234 3,630 3,430 1,080 - 6,450 Pass ERS0-1105 3/14/2016 U-233/234 3,090 3,460 2, 110 - 4,430 Pass ERS0-1105 3/14/2016 U-238 3,280 3,430 2, 120 - 4,350 Pass ERS0-1105 3/14/2016 Zn-65 2,940 2,450 1,950 - 3,260 Pass ERW-1115 3/14/2016 Gr. Alpha 105.0 117.0 41.5 -181.0 Pass ERW-1115 3/14/2016 Gr. Beta 76.2 75.5 43.2 - 112.0 Pass ERW-1117 3/14/2016 H-3 8,870 8,650 5,800 -12,300 Pass A7-1

TABLEA-7. lnterlaboratory Comparison Crosscheck Program, Environmental Resource Associates (ERA)".

MRAD Study Concentration a Lab Code b Date Analysis Laboratory ERA Control Result Result Limits Acceptance ERVE-1108 3/14/2016 Am-241 1,930 2,120 1,300 - 2,820 Pass ERVE-1108 3/14/2016 Cm-244 1,294 1,560 764 -2,430 Pass ERVE-1108 3/14/2016 Co-60 1,164 1,100 759 - 1,540 Pass ERVE-1108 3/14/2016 Cs-134 1,056 1,070 687 - 1,390 Pass ERVE-1108 3/14/2016 Cs-137 930 838 608 - 1, 170 Pass ERVE-1108 3/14/2016 K-40 32,200 31,000 22,400 - 43,500 Pass ERVE-1108 3/14/2016 Mn-54

<24.5

<300 0.00 - 300 Pass ERVE-1108 3/14/2016 Zn-65 3,320 2,820 2,030 - 3,960 Pass ERVE-1108 3/14/2016 Pu-238 3,410 2,810 1,680 c 3,850 Pass ERVE-1108 3/14/2016 Pu-239/240 4,120 3,640 2,230 - 5,010 Pass ERVE-1108 3/14/2016 Sr-90 8,120 8,710 4,960 - 11,500 Pass ERVE-1108 3/14/2016 U-233/234 4,350 4,160 2,740 - 5,340 Pass ERVE-1108 3/14/2016 U-238 4,220 4,120 2,750 - 5,230 Pass ERW-1111 3/14/2016 Am-241 113 121 81.5-162 Pass ERW-1111 3/14/2016 Co-60 1, 120 1,050 912 -1,230 Pass ERW-1111 3/14/2016 Cs-134 806 842 618 - 968 Pass ERW-1111 3/14/2016 Cs-137 1,190 1,100 934 - 1,320 Pass ERW-1111 3/14/2016 Mn-54

<5.89

< 100 0.00 -100 Pass ERW-1111 3/14/2016 Pu-238 159 138 102 - 172 Pass ERW-1111 3/14/2016 Pu-239/240 113 98.7 76.6 - 124 Pass ERW-1111 3/14/2016 U-233/234 46.9 52.7 39.6 - 68.0 Pass ERW-1111 3/14/2016 U-238 50.4 52.3 39.9 - 64.2 Pass ERW-1111 3/14/2016 Zn-65 1,160 1,010 842 - 1,270 Pass ERW-1111 3/14/2016 Fe-55 1,600 1,650 984 - 2,240 Pass ERW-1111 3/14/2016 Sr-90 430 434 283 - 574 Pass

  • Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).

b Laboratory codes as follows: ERW (water), ERAP (air filter), ERSO (soil), ERVE (vegetation). Results are reported in units of pCi/L, except for air filters (pCi/Filter), vegetation and soil (pCi/kg).

0 Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

A7-2

APPENDIX 8.

DATA REPORTING CONVENTIONS Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Single Measurements Each single measurement is reported as follows:

x +/- s where:

x = value of the measurement; s = 2cr counting uncertainty (corresponding to the 95% confidence level).

In cases where the activity is less than the lower limit of detection L, it is reported as: < L, where L = the lower limit of detection based on 4.66cr uncertainty for a background sample.

3.0. Duplicate analyses If duplicate analyses are reported, the convention is as follows. :

3.1 Individual results: For two analysis results; x1 +/- s1 and x2 +/- s2 Reported result:

x +/- s; where x = (1/2) (x1 +~)ands= (1/2) ~ s; + s~

3.2.

Individual results:

< L1, < L2 Reported result: < L, where L = lower of L1 and L2 3.3.

Individual results:

x +/- s, < L Reported result:

x +/- s if x ~ L; < L otherwise.

4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an ~nnual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation "s" of a set of n numbers x1, x2... xn are defined as follows:

--~

s-

-\\J~

4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1. If the number following those to be retained is less than 5, the number is dropped, and the retained numbers are kept unchanged. As an example, 11.443 is rounded off to 11.44.

4.5.2.

If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1.

As an* example, 11.445 is rounded off B-1

APPENDIX C Table C-1.

Maximum permissible concentrations of radioactivity in air and water above natural a

background in unrestricted areas.

Air (pCi/m 3

)

Water (pCi/L)

-3 Gross alpha 1x10 Strontium-89 8,000 Gross beta 1

Strontium-90 500 b

-1 lodine-131 2.8 x 10 Cesium-137 1,000 Barium-140 8,000 lodine-131 1,000 c

Potassium-40 4,000 Gross alpha 2

Gross beta 10 6

Tritium 1x10 a

Taken from Table 2 of Appendix B to Code of Federal Regulations Title 10, Part 20, and appropriate footnotes.

Concentrations may be averaged over a period not greater than one year.

b Value adjusted by a factor of 700 to reduce the dose resulting from the air-grass-cow-milk-child pathway.

c A natural radionuclide.

C-1

2016 Annual Radiological Environinental Operating Report Kewaunee Power Station Part II, Data Tabulations And Analyses Dominion Energy Kewaunee, Inc.

- ~~/!1 ATI Environmental, Inc.

~~~/"'\\I Midwest Laboratory 700 Landwehr Road

  • Northbrook, IL 60062-2310 phone (847) 564-0700 *fax (847) 564-4517 REPORT TO DOMINION NUCLEAR RADIOLOGICAL MONITORING PROGRAM FOR THE KEWAUNEE POWER STATION KEWAUNEE, WISCONSIN Approved:

ANNUAL REPORT - PART II DAT AT ABULATIONS AND ANALYSES January 1 to December 31, 2016 Prepared and submitted by ATI ENVIRONMENTAL, Inc.

Midwest Laboratory Project No. 8002 J Michael Hale adiation Protection I hemistry Mgr., KPS

This Page Intentionally Left Blank

PREFACE Staff members of ATI Environmental, Inc., Midwest Laboratory were responsible for the acquisition of data presented in this report. Samples were collected by personnel of ATI Environmental, Inc.,

Midwest Laboratory and the Kewaunee Power Station.

ii

This Page Intentionally Left Blank

TABLE OF CONTENTS Section Page Preface....................................................................................................................................................

ii List of Figures..........................................................................................................................................

iv List of Tables...........................................................................................................................................

v

1.0 INTRODUCTION

2.0 3.0 GRAPHS OF DATA TRENDS.................................................................................................................

DATA TABULATIONS.............................................................................................................................

iii 7

20

No.

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 LIST OF FIGURES Caption Sampling locations, Kewaunee Power Station Airborne particulates, weekly averages; gross beta, Airborne particulates, gross beta, monthly averages, Well water, gross alpha in total residue, Well water, gross beta in total residue, Milk, strontium-90 activity, Surface water, gross beta (total residue),

Surface water, tritium activity, iv Location K-1f Location' K-2 Location K-8 Location K-31 Location K-41 Location K-43 Location K-1f Location K-2 Location K-8 Location K-31 Location K-41 Location K-43 Location K-1g Location K-1 h Location K-1g Location K-1 h Location K-10 Location K-11 Location K-13 Location K-38 Location K-3 Location K-5 Location K-34 Location K-35 Location K-38 Location K-39 Location K-39 Location K-44 Location K-1a Location K-1 b Location K-1d Location K-1e Location K-1 k Location K-9 Location K-14a Location K-1d Location K-14a Location K-9 Page 2

8 8

8 9

9 9

10 10 10 11 11 11 12 12 13 13 13 13 14 14 15 15 15 15 16 16 16 16 17 17 17 17 18 18 18 19 19 19

No.

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 LIST OF TABLES Sampling locations, Kewaunee Power Station Type and frequency of collection Sample codes used in Table 2 Title Airborne particulates and iodine, analysis for gross beta and iodine-131 Location K-1f Location K-2 Location K-8 Location K-31 Location K-41 Location K-43 Airborne particulates, gross beta, monthly averages, minima and maxima Airborne particulates, quarterly composites of weekly samples, analysis for gamma-emitting isotopes Ambient gamma radiation (TLD), quarterly exposure Precipitation, collected at Location K-11, analysis for tritium Milk, analysis for iodine-131 and gamma emitting isotopes Milk, analysis for strontium-89, strontium-90, calcium and potassium-40 Well water, analysis for gross alpha, gross beta, tritium, strontium-89, strontium-90, potassium-40, and gamma-emitting isotopes.

Well water, analysis for gross beta, tritium, potassium-40 and gamma-emitting isotopes Domestic meat, analysis of flesh for gross alpha, gross beta, and gamma-emitting isotopes Eggs, analysis for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes Vegetables, analysis for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes Cattlefeed, analysis for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes Grass, analysis for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes Soil, analysis for gross alpha, gross beta, strontium-89, strontium-90 and gamma-emitting isotopes Surface water, analysis for gross beta, potassium-40, and gamma-emitting isotopes Surface water, analysis for tritium, strontium-89, and strontium-90 Fish samples, analysis for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes Slime, analysis for gross beta, strontium-89, strontium-90 and gamma emitting isotopes Bottom sediments, analysis for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes v

Pae 3

5 6

21 22 23 24 25 26 27 29 32 33 34 38 41 42 44 45 46 48 50 53 56 74 76 77 80

This Page Intentionally Left Blank

1.0 INTRODUCTION

The following constitutes Part II of the final report for the 2016 Radiological Monitoring Program conducted at the Kewaunee Power Station (KPS), Kewaunee, Wisconsin.

Included are tabulations of data for all samples collected in 2016 along with graphs of data trends.

A summary and interpretation of the data presented here are published in Part I of the 2016 Annual Report on the Radiological Monitoring Program for the Kewaunee Power Station.

1

Figure 1. Sampling locations, Kewaunee Power Station

  • ~BAY!
  • l"MER'S DAD!YI ---"""--+---""'-----<

I...

$CALE 2

A

Table 1. Sampling locations, Kewaunee Power Station.

Distance (miles)b Code Type 8

and Sector Location K-1 Onsite K-1a 0.62 N North Creek K-1b 0.12 N Middle Creek K-1c 0.10 N 500' north of condenser discharge K-1d 0.10 E Condenser discharge K-1e 0.12 s South Creek K-1f 0.12 s Meteorological Tower K-1g 0.06W South Well K-1h 0.12 NW North Well K-1j 0.10 s 500' south of condenser discharge K-1k 0.60 SW Drainage Pond, south of plant K-11 0.13 N ISFSI Southeast K-1m 0.15 N ISFSI East K-1n 0.16 N ISFSI Northwest K-1o 0.16 N ISFSI North K-1p 0.17 N JSFSI Northwest K-1q 0.16 N ISFSI West K-1r 0.13 N ISFSI West K-1s 0.12 N ISFSI Southwest K-2 c

8.91 NNE WPS Operations Building in Kewaunee K-3 c

5.9 N Lyle and John Siegmund Farm, N2815 Hy 42, Kewaunee K-5 3.2 NNW Ed Paplham Farm, E4160 Old Settlers Rd, Kewaunee K-8 c

4.85WSW St. Isadore the Farmer Church, 18424 Tisch Mills Rd, Tisch Mills K-9 c

11.5NNE Green Bay Municipal Pumping Station, six miles east of Green Bay (sample source is Lake Michigan water from Rostok Intake, two miles north of Kewaunee).

K-10 1.35 NNE Turner Farm, Kewaunee site K-11 0.96 NW Louise Ihlenfeld Farm, N879 Hy 42, Kewaunee K-13 c

3.0 SSW Rand's General Store, Two Creeks K-14 I

2.6 s Two Creeks Park, 2.6 miles south of site K-15 c

9.25 NW Gas Substation, 1.5 miles north of Stangelville K-17 4.0W Klimesh's Farm, N885 Tk B, Kewaunee K-23a 0.5W 0.5 miles west of plant, Kewaunee site K-23b 0.6 N 0.6 miles north of plant, Kewaunee site K-24 5.4 N Fictum Farm, N2653 Hy 42, Kewaunee K-25 1.9SW Wotachek Farm, 3968 E. Cty Tk BB, Two Rivers K-26 c

9.1 SSW Wilfert Farms (9.1 miles south of "BB")

3

Table 1. Sampling locations, Kewaunee Power Station (continued).

Distance (miles)b Code Type 8

and Sector Location K-27 1.53 NW Schleis Farm, E4298 Sandy Bay Rd, Kewaunee K-29 5.34W Kunesh Farm, E3873 Cty Tk G, Kewaunee K-30 0.8 N End of site boundary K-31 c

6.35 NNW E. Krok Substation, Krok Road K-32 c

7.8 N Piggly Wiggly, 931 Marquette Dr., Kewaunee K-34 2.7 N Leon and Vicki Struck, N1549 Lakeshore Dr., Kewaunee K-35 c

6.71 mi. WNW Duane Ducat, N1215 Sleepy Hollow Rd., Kewaunee K-36 8.0 mi. NNE Lafond's Fish market, 216 Milwaukee, Kewaunee K-38 2.45 mi. WNW Dave Sinkula Farm, N890 Town Hall Road, Kewaunee K-39 I

3.46 mi. N Francis Wojta, N1859 Lakeshore Dr., Kewaunee K-41 c

22NW Point Beach-EOF, 3060 Voyager Dr., Green Bay K-42 c

28.1 w Lamers Dairy Products obtained from Green Bay markets.

K-43 2.71 SSW Gary Maigatter Property, 17333 Hwy 42, Two Rivers K-44 2.63 SW Gerald Schleis Property, 4728 Schleis Rd., Two Rivers a I = indicator; C = control.

b Distances are measured from reactor stack.

4

Table 2. Type and frequency of collection.

Location Weekly K-1a K-1b K-1c K-1d K-1e K-1f AP 9,AI K-1a, K-1h K-1i K-1k K-11 throuah K-1s K-2 AP 9,AI K-3, K-5 K-8 AP 9,AI K-9 K-10, K-13 K-11 K-14 K-15, K-17 K-23a, b K-24 K-25 K-26 K-27 K-29 K-30 K-31 AP 9, Al K-32 K-34, K-35 K-36 K-38 K-39 K-41 AP 9,AI K-42 K-43 AP 9,AI K-44

  • Three times a year, second, third and fourth quarters.

b Collected in May and November.

0 Monthly November - April; semimonthly May-October.

d First quarter (January, February or March) only.

  • Alternate, if milk is not available.

1 Second and third quarters.

Monthly SW SW SW SW SW Ml 0

sw; PR swh Ml 0

Ml 0

Ml 0

Ml 0

Ml 0

5 Quarterly Semiannually Annually SL 1 GR" SL 1 BS b Fl a SL 1 BSb SL 1 GR" TLO so WW BSb SL 1 TLO TLD GR" TLO so CFd TLO SL 1 BS b WW WW SL 1 BS b TLO GRN /GLV" EG OM TLO VE/GLV" TLO OM TLO TLO EG OM GR" so CFd Fl aj GR" WW so CFd GR" TLO so CFd TLO TLO 9 Frequency may be increased dependent on dust loading.

h Two samples are collected, North (K-14a) and South (K-14b) ofTwo Creeks Road.

Two samples, raw and tap water.

i Collected at K-36 if K-1 d is unavailable

Table 3. Sample Codes:

Code Al AP BS CF DM EG Fl GLV GRN GR Ml PR SL so SW TLD VE WJV Description Airborne Iodine Airborne particulates Bottom sediments Cattlefeed Domestic Meat Eggs Fish Green Leafy Vegetables Grain Grass Milk Precipitation Slime Soil Surface water Thermolum inescent Dosimeter Vegetables Well water 6

GRAPHS OF DATA TRENDS Note: Conventions used in trending data.

The following conventions should be used in the interpretation of the graphs of data trends:

1. Both solid and open data points may be used in the graphs. A solid point indicates an activity, an open point, a lower limit of detection (LLD) value.
2. Data points are connected by a solid line. A break in the plot indicates missing data.

7

0.100 0.080 0.060 pCi/m3 0.040 0.020 0.100 0.080 0.060 pCi/m3 0.040 0.020 0.100 0.080 0.060 pCi/m3 0.040 0.020 I\\/\\

v

~

I ft.

I\\ I\\

\\/. '.J

!\\ "

v ' ~

Air Particulates - Gross Beta KPS I\\ /\\

-r "\\

/\\

/\\ - /\\ /\\ I \\/

!\\_ /Y

- \\j - "'._ J \\ V"'--./

"' "' fl '

Figure 2. Location K-1f (weekly samples, 2016).

/\\..

/\\ IV* "/v "J ~. /'

1....-

v....

\\....

~

[\\ r" v

Figure 3. Location K-2 (weekly samples, 2016).

I\\

!\\ I \\

fr-.

./.....

......-\\

I \\f yv-v ~

I\\ I" ~~

"\\./ fl

\\--

v Figure 4. Location K-8 (weekly samples, 2016).

8

0.100 0.080 0.060 pCi/m3 0.040

~ \\/",

Air Particulates - Gross Beta r--...

A

. /\\

0.020

"--V V""-~ /--. ~/\\, /-....--.. v 0.100 0.080 0.060 pCi/m3 0.040 0.020 0.000 0.100 0.080 0.060 pCi/m3 0.040 0.020 V\\ /\\

v "'I\\

J Y---1

/\\.

\\/'\\

. "--_/

Figure 5. Location K-31 (weekly samples, 2016).

f-1-<t

/\\

'J V\\ /'-/' vY

,,..- V\\/

v v

Figure 6. Location K-41 (weekly samples, 2016).

/'-.-.. ~A

~

~

~

~..,,/

~

y Figure 7. Location K-43 (weekly samples, 2016).

9 KPS

. /\\

/\\ !" \\. /V v......,

1\\

..--'\\ IV " I\\~

v v

1\\

f\\ I\\

/\\ I y I\\ ;-I

\\...-

v

0.100 0.080 0.060 pCVm3 0.040

\\

0.020 0.000 2012 0.100 0.080 0.060 pCi/m3 0.040

\\

0.020 0.000 2012 0.100 0.080 0.060 pCi/m3 0.040 0.020 0.000 2012 Air Particulates - Gross Beta KPS

~

-'\\

. I

\\

A

,..... h

"'-.. _/V

\\.___

J ~

A J hi \\

/'J \\

~ I'

~v

~-

\\_J

~.......,......

2013 2014 2015 2016 Figure 8. Location K-1f (monthly averages, 2012-2016).

r r--.

I \\

I

~

'-..._/ "./"

~

) ~ A./

h" \\

(\\/ \\

/'

T v

'"'-/VV

~/

~

\\J 2013 2014 2015 2016 Figure 9. Location K-2 (monthly averages, 2012-2016).

,,, I\\

J

\\

II.

""---- /

~~- I ~

).J \\

Al \\

. I\\

. v

'...._/ ".---" v

'-----./

v~V--

2013 2014 2015 2016 Figure 10. Location K-8 (monthly averages, 2012-2016).

10

0.100 0.080 0.060 pCi/m3 0.040

~

0.020 0.000 2012 0.100 0.080 0.060 pCi/m3

/~

Air Particulates - Gross Beta KPS

~

I \\

)

~. J ~,...

,,,-1\\

/\\./ \\

/\\

____.,, v

"~ \\___/

.... "--../

2013 2014 2015 2016 Figure 11. Location K-31 (monthly averages, 2012-2016).

/ \\

I"._

(

\\

~

J-.....

0.040 0.020 0.000 2012 0.100 0.080 0.060 pCi/m3 0.040 0.020 0.000 2012 VJ"'

~---

j ~,...

f--/ \\

/V \\

/"

v

'"-._/..._.... v

\\_,-J

~

2013 2014 2015 2016 Figure 12. Location K-41 (monthly averages, 2012-2016).

-r\\

I \\

/I.

!\\

~

~/\\

)\\

.?..

J ~\\

Ar '\\

_/

v '--/

~v \\__._/

~

2013 2014 2015 2016 Figure 13. Location K-43 (monthly averages, 2012-2016).

11

Well Water - Gross Alpha KPS 6 -<-~~~~~~--t-~~~~~~-+~~~~~~~t--~~~~~~-+-~~~~~~~

pCi/L 4 -<-~~~~~~--t-~~~~~~-+~~~~~~~t--~~~~~~-+--+---+~~~~->

0 +-~~~~~~-t-~~~~~~-+~~~~~~~+-~~~~~~-+-~~~~~~__J 2012 2013 2014 2015 2016 Figure 14. Location K-1g. Total Residue. Quarterly collection.

6 +-~~~~~~-t-~~~~~~-+~~~~~~~+-~~~~~~-+-~~~~~~-"

pCi/L 4 -',.._~~~~~-t-~~~~--/-"<---+~~~~~~~+-~~~~~~-+--+-4~~~~-"

0 -<-~~~~~~--t-~~~~~~-+~~~~~~~-t--~~~~~~-+-~~~~~~~

2012 2013 2014 2015 2016 Figure 15. Location K-1h. Total Residue. Quarterly collection.

12

Well Water - Gross Beta pCi/L 6 -i-~~~~~~--1~~~~~~~-+-~~~~~~~-i-~~~~~~--1~~~~~~~~

0 +-~~~~~~--1~~~~~~~-1-~~~~~~~+-~~~~~~-+~~~~~~----J 2012 2013 2014 2015 2016 Figure 16. Location K-1g. Total Residue. Quarterly collection.

pCi/L 6 -i-~~~~~~---1~~~~~+-'----+-~~~~~~~+-~~~~~~--lf--~~~~~~-1 o +-~~~~~~--1~~~~~~~-+-~~~~~~~+-~~~~~~---1~~~~~~~-'

2012 2013 2014 2015 2016 Figure 17. Location K-1h. Total Residue. Quarterly collection.

pCi/L 6 -i-~~~~~~--1~~~~~~~--t-~~~~~~~+-~~~~~~---1~~~~~~~-1 10 8

pCi/L 6

4 2

r-...

o 2012 2013 2014 2015 2016 Figure 18. Location K-10. Total Residue. Quarterly collection.

~~

~

L-'

2013 2014 2015 2016 Figure 19. Location K-11. Total Residue. Quarterly collection.

Note: An open data point indicates activity less than the lower limit of detection (LLD).

13 J\\ /\\ \\-

KPS

Well Water - Gross Beta

  • pCi/L 6 +-~~~~~~~+-~~~~~~~+-~~~~~~~+-~~~~~~~-+-~~~~~~~~

0 +-~~~~~~~+-~~~~~~~+-~~~~~~~+-~~~~~~~-+-~~~~~~~~

2012 2013 2014 2015 2016 Figure 20. Location K-13. Total Residue. Quarterly collection.

35 i==============i==============i===============i===============i==============i 30 +-~~~~~~~+-~~~~~~~+--~~~~~~~+--~~~~~~~-+--~~n~~~~~--<

I pCi/@5 -J:=:::::::=:::::::=:::::::::::::::::::::::=:::::::=$:::::::=:::::::=:::::::::::::::::::::::=:::::::==$:::::::=:::::::=::::::::::::::::::::::::::::::::::::::::1==:::::::::::::::::::::::::::::::::::::::=:::::::=$=J'.=:\\=:::::::=:::::::=::::::::::::::::=1 20 +-~~~~~~~+-~~~~~~~+-~~~~~~~+-~~~~~~~+--1-~r--~~~----1 15 i===============:t===============:t===============:t===============:t:=~'==:=!i;::=========1 10 +-~~~~~~~+-~~~~~~~+-~~~~~~~-1-~~~~~~~-r-i'~~-+-'~~~-1 5 -l================t=================t======---:::;~===-=====t================'tf:====:::::i~,====/~

o.t:=:==t:==1;::::::~::;j;;~::::::;;;;;;;;;;;~===*==~'.::::::~::::::$=:::!::~==~~====:i:::::::::!'.'.=:j 2012 2013 2014 2015 2016 Figure 21. Location K-38. Total Residue. Quarterly collection.

14 KPS

Milk - Strontium-90

...J a 1.5 +--~~~~~~--+~~~~~~~-+--~~~~~~--+~~~~~~~-+--~~~~~~---l

0.

1.0 +-~~-=----7'r--.,.-A-+f-~~-=-~~~*°""'~'"""=:--~--o-~-+-=-_,..~~~~~+-~---,jt-~~~1H 0.5 -!--'=-~~~--=-~--+~~~--=~=--~+-~~~~'--=¥---F'---------=-~--"="""'~+-~"------"~~¥---1 0.0 +-~~~~~~--+~~~~~~~-1--~~~~~~--+~~~~~~~-I--~~~~~~-'

2012 2013 2014 2015 2016 Figure 22. Milk samples. Location K-3.

3.0 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

2.5 +-~~~~~~--+~~~~~~~-1--~~~~~~--+~~~~~~~-+-~~~~~~---l

...J 0 2.0

0.

...J a

0.

1.5 +-~~~~~~--+~~~~~~~-1--~~~~~~--+~~~~~~~-+-~~~~~~---l 1.0 +-~~~~~~--+~~~~~~l-\\--l--~~~~~~---1...-~~~~~~-+-~~~~~~---l 0.5~~~~'.'.........:~4-~:!::!'.'.::::__~::::!_..\\.4~~~~~~-J_..":~.d..._~{__..:_~~~~~,L:_:.J,L:::j 0.0 -t-~~~~~~--+~~~~~~~-+-~~~~~~--+~~~~~~~-+-~~~~~~---'

2012 2013 2014 2015 2016 Figure 23. Milk samples. Location K-5.

1.5 -t-~~~~~~--+~~~~~~~-1--~~~~~~--+~~~~~~~-1--~~~~~~-j 1.0.P..,.~~---~~~-J?.--~~--~~~-1--~~-J.J.~~~--+~~~~~~~-1--~~~~~~-4 0.5 +---~~~~~~--1-___.:~~----\\l~~.4-~"""'""""'f.--~'--~~.},....,,~~~~............,f....)....!~.F-~""-<?--:.'>l-----I o.o+-~~~~~~--+~~~~~~~-1--~~~~~~--+~~~~~~~-1--~~~~~~-'

2012 3.0 2.5 2.0 1.5 1.0 0.5 0.0 2012

~ /\\....-".. ~

v 2013

~

"V 2013 2014 2015 2016 Figure 24. Milk samples. Location K-34.

/""-....

~

~.

~ /' V\\.

l

?-..

~

2014 2015 2016 Figure 25. Milk samples. Location K-35.

15 KPS

...J

~

+~~~~~~~--+~~~~~~~-1-~~~~~~~-+-~~~~~~~-+-~~~~~~---1

0. 2.0 1.5 +-~~~~~~~+-~~~~~~~t--~~~~~~----1f--~~~~~~----<~~~~~~~-<

1.0-b-"'7-"""<--~~-J'~..--,,,___:.\\--Jt;--A--J'..;.=--+"-\\--=-"'-'\\-----iA-----t--f-'-----¥---\\-,--~...,..~f--~--:--~-=:=----I 0.5 +-~~~4/-~~~+-~~~__;:.._...::.._~1--~~~~~--==>?11--~~~.::._--=--~---'1--=--->or---=-~~'¥---"

0.0 +-~~~~~~~+-~~~~~~~t--~~~~~~----11--~~~~~~---1~~~~~~~~

2012 2013 2014 2015 2016 Figure 26. Milk samples. Location K-38.

3.,--~~~~~~~.,--~~~~~~~~~~~~~~~.--~~~~~~~.--~~~~~~~

2.5 +-~~~~~~~+-~~~~~~~t--~~~~~~~t----~~~~~~~f--~~~~~~--<

0 +-~~~~~~~+-~~~~~~~+-~~~~~~~f--~~~~~~~f--~~~~~~~

2012 2013 2014 2015 2016 Figure 27. Milk samples. Location K-39.

~ 2.0 +-~~~~~~~+-~~~~~~~+-~~~~~~~+-~~~~~~~-+-~~~~~~~~

(3

0. 1.5 +-~~~~~~~+-~~~~~~~+-~~~~~~~+-~~~~~~~-+-~~~~~~--I 1.0 -J>o<;r>r~~~~~--j,.---~-;;-~~~--j..-n""w"""~~~~~-j---,~~---;,.---~--j~~~~~~~~

0_5_j____:__:~~c:___j____:':!!___::~==:__j__~-=~~--=:._+..:'"".'.'._~~___:o~~c__~:::::.o~~~

0.0 +-~~~~~~~-+-~~~~~~~-+-~~~~~~~-+-~~~~~~~-+-~~~~~~~~

2012 2013 2014 2015 2016 Figure 28. Milk samples. Location K-42.

3 2.5 s

2

(.)

0. 1.5 0.5

~

0 2012 2013 2014.

2015 2016 Figure 29. Milk samples. Location K-44.a a Last collection Jan. 2013. Dairy out of business. Cows sold.

16

80 70 60 50 pCi/L 40 30 20 10 -

0 2012 pCi/L

~

II II I I I

I I

.L

.r I

T Surface Water-Gross Beta II I

I I

I I

I I

I I

I I

/I r

\\

. r I

I V'

\\

..../ '\\

I 1.....- -

./

'\\ "

~

i

~.

2013 2014 2015 2016 Figure 30. Surface water. North Creek, Onsite (K-1 a).

10 +-~~~~~~-+-~~~~~~-+-~~-1+-~~~-+-~~~~~~-+-~~~~~-+~

0 +-~~~~~~-+-~~~~~~-+-~~~~~~-+-~~~~~~-+-~~~~~~~

2012 20.0 pCi/L 10.0 0.0 2012 40 30 pCi/L 20 10

~

V-'

0 2012 2013 2014 2015 2016 Figure 31. Surface water. Middle Creek, Onsite (K-1 b).

/'. ~~

~

~

. /~

~ v T

~

T.

2013 2014 2015 2016 Figure 32. Surface water. Lake Michigan, condenser discharge, On site (K-1 d).

~

I f \\

I \\

~

\\

~ I \\/\\

I \\--\\

\\

~y-.J

+-¥ v.,,

T A

............/

~

T T

2013 2014 2015 2016 Figure 33. Surface water. South Creek, Onsite (K-1e).

17 KPS

Surface Water-Gross Beta KPS 30.0 --------11---------+-------+-------t---------1 pCi/L 20.0 -t-------..~---11-------\\----t---------j-----t11---t---------1 0.0 --------1--------+-------+-------t---------1 2012 2013 2014 2015 2016 Figure 34. Surface water. School Forest Pond (K-1k).

pCi/L 10 +---------1--------+--------+-------+---------I o.f::!:'.~::!::!:~~+:!=~~~~-+=-'---'.'.:::!:::!::::!:::~q_::~-=~~:!:::+=:__..:::!::~L__~

2012 2013 2014 2015 2016 Figure 35. Surface water (raw). Lake Michigan, Rostok Intake (K-9) pCi/L 0 +-------1--'---~----+----~--1--------1------~

2012 2013 2014 2015 2016 Figure 36. Surface water. Lake Michigan, Two Creeks Park (K-14a).

18

Surface Water - Tritium 5000 s4ooo

(.)

c.

3000 2000 1000

""-"'¥ 0

2012 A.

,J 2013 I\\ I\\

I

\\

\\.

~

A 2014 2015 2016 Figure 37. Surface water. Lake Michigan, condenser discharge, K-1d. Quarterly collection.

1000 900 s 800

()

a.700 600 500 400

.300 200 100 2012 I\\.

I \\

,./

\\.

~

~

v-2013 2014 2015 2016 Figure 38. Surface water. Lake Michigan, Two Creeks Park, K-14a. Quarterly collection.

1000..-~~~~~~.--~~~~~----.~~~~~~-.~~~~~~--.--~~~~~~

900 +-~~~~~~1--~~~~~-+~~~~~~--+-~~~~~~-+-~~~~~---.

~800 +-~~~~~~t---~~~~~--t-~~~~~~-+-~~~~~~-t-~~~~~-----j C3 a.700 +-~~~~~~1--~~~~~-+~~~~~~--+-~~~~~~-+-~~~~~---.

600 +-~~~~~~t---~~~~~--t-~~~~~~-+-~~~~~~-t-~~~~~-----j 500 +-~~~~~~t---~~~~~--t-~~~~~~-+-~~~~~~-t-~~~~~-----j 400 +-~~~~~~1---~~~~~--t-~~~~~~-+-~~~~~~-t-~~~~~___,

300 +-~~~~~~1--~~~~~-+~~~~~~--+-~~~~~~-;-~~~~~--,

200 +-~~~~~~r-~~~~~-t~~~~~~--,t--~~~~~~-r--~~~~~___,

A 100 +-~~~~~~1---~~~~~--t-~~~~~~-+-~~*~~~~-t-~~~~~~

2012 2013 2014 2015 2016 Figure 39. Surface water. Lake Michigan, Rostek Intake, K-9. Quarterly collection.

19 KPS

KPS DATA TABULATIONS 20

KPS Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131°.

Location: K-1f Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3)

Gross Beta Collected (m3)

Gross Beta Reguired LLD 0.010 Reguired LLD 0.010 01-05-16 294 0.040 +/- 0.005 07-05-16 303 0.016 +/- 0.004 01-12-16 302 0.026 +/- 0.004 07-12-16 302 0.020 +/- 0.004 01-19-16 301 0.039 +/- 0.005 07-19-16 303 0.021 +/- 0.004 01-26-16 303 0.032 +/- 0.005 07-26-16 303 0.021 +/- 0.004 02-02-16 301 0.027 +/- 0.005 08-02-16 303 0.016 +/- 0.004 02-09-16 303 0.022 +/- 0.005 08-09-16 302 0.023 +/- 0.004 02-16-16 302 0.018 +/- 0.004 08-16-16 302 0.027 +/- 0.004 02-23-16 303 0.016 +/- 0.005 08-23-16 224 0.019 +/- 0.005 03-01-16 302 0.025 +/- 0.004 08-30-16 305 0.018 +/- 0.004 03-08-16 312 0.019 +/- 0.004 09-06-16 302 0.021 +/- 0.004 03-15-16 291 0.021 +/- 0.005 09-13-16 301 0.017 +/- 0.004 03-22-16 304 0.013 +/- 0.004 09-20-16 302 0.027 +/- 0.004 03-29-16 302 0.029 +/- 0.004 09-27-16 303 0.019 +/- 0.004 1st Quarter Mean +/- s.d.

0.025 +/- 0.008 3rd Quarter Mean +/- s.d.

0.020 +/- 0.004 04-05-16 302 0.025 +/- 0.004 10-04-16 304 0.015 +/- 0.004 04-12-16 304 0.019 +/- 0.004 10-11-16 300 0.023 +/- 0.004 04-19-16 304 0.020 +/- 0.004 10-18-16 302 0.027 +/- 0.004 04-26-16 301 0.016 +/- 0.004 10-25-16 303 0.018 +/- 0.004 05-03-16 299 0.012 +/- 0.004 11-01-16 301 0.015 +/- 0.004 05-10-16 301 0.009 +/- 0.004 11-08-16 307 0.035 +/- 0.005 05-17-16 303 0.015 +/- 0.004 11-15-16 300 0.020 +/- 0.004 05-24-16 302 0.029 +/- 0.005 11-22-16 302 0.041 +/- 0.005 05-31-16 303 0.021 +/- 0.004 11-29-16 304 0.032 +/- 0.005 06-07-16 302 0.012 +/- 0.003 12-06-16 302 0.023 +/- 0.004 06-14-16 302 0.016 +/- 0.004 12-13-16 302 0.019 +/- 0.004 06-21-16 303 0.019 +/- 0.004 12-20-16 304 0.031 +/- 0.005 06-28-16 305 0.016 +/- 0.004 12-27-16 302 0.025 +/- 0.004 01-03-17 302 0.029 +/- 0.004 2nd Quarter Mean +/- s.d.

0.018 +/- 0.005 4th Quarter Mean +/- s.d.

0.025 +/- 0.008 Cumulative Average 0.022 0 lodine-131 concentrations are< 0.03 pCi/m3 unless otherwise noted.

21

KPS Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8 Location: K-2 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3)

Gross Beta Collected (m3)

Gross Beta Reguired LLD 0.010 Reguired LLD 0.010 01-05-16 295 0.036 +/- 0.005 07-05-16 300 0.016 +/- 0.004 01-12-16 299 0.018 +/- 0.004 07-12-16 302 0.019 +/- 0.004 01-19-16 306 0.030 +/- 0.005 07-19-16 258 0.019 +/- 0.004 01-26-16 303 0.045 +/- 0.005 07-26-16 303 0.018 +/- 0.004 02-02-16 302 0.022 +/- 0.004 08-02-16 303 0.018 +/- 0.004 02-09-16 302 0.017 +/- 0.005 08-09-16 301 0.020 +/- 0.004 02-16-16 303 0.014 +/- 0.004 08-16-16 302 0.025 +/- 0.004 02-23-16 296 0.011 +/- 0.004 08-23-16 303 0.020 +/- 0.004 03-01-16 304 0.024 +/- 0.004 08-30-16 305 0.019 +/- 0.004 03-08-16 301 0.019 +/- 0.004 09-06-16 302 0.020 +/- 0.004 03-15-16 300 0.014 +/- 0.004 09-13-16 301 0.015 +/- 0.004 03-22-16 298 0.014 +/- 0.004 09-20-16 305 0.022 +/- 0.004 03-29-16 302 0.020 +/- 0.004 09-27-16 301 0.017 +/- 0.004 1st Quarter Mean+/- s.d.

0.022 +/- 0.010 3rd Quarter Mean +/- s.d.

0.019 +/- 0.003 04-05-16 303 0.020 +/- 0.004 10-04-16 304 0.018 +/- 0.004 04-12-16 304 0.016 +/- 0.004 10-11-16 299 0.019 +/- 0.004 04-19-16 304 0.017 +/- 0.004 10-18-16 302 0.029 +/- 0.004 04-26-16 301 0.016 +/- 0.004 10-25-16 303 0.016 +/- 0.004 05-03-16 299 0.012 +/- 0.004 11-01-16 303 0.015 +/- 0.004 05-10-16 260 0.005 +/- 0.004 11-08-16 305 0.034 +/- 0.005 05-17-16 313 0.012 +/- 0.004 11-15-16 308 0.021 +/- 0.004 05-24-16 292 0.019 +/- 0.004 11-22-16 300 0.034 +/- 0.005 05-31-16 303 0.016 +/- 0.004 11-29-16 305 0.027 +/- 0.004 06-07-16 303 0.009 +/- 0.003 12-06-16 295 0.023 +/- 0.004 06-14-16 302 0.013 +/- 0.004 12-13-16 303 0.018 +/- 0.004 06-21-16 302 0.014 +/- 0.004 12-20-16 303 0.027 +/- 0.004 06-28-16 NDb 12-27-16 308 0.024 +/- 0.004 01-03-17 305 0.027 +/- 0.004 2nd Quarter Mean +/- s.d.

0.014 +/- 0.004 4th Quarter Mean +/- s.d.

0.024 +/- 0.006 Cumulative Average 0.020 a lodine-131 concentrations are< 0.03 pCi/m3 unless otherwise noted.

b ND - No Data. 6/28/16 Power was found off. Power was restored and filter changed.

22

KPS Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a.

Location: K-8 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3)

Gross Beta Collected (m3)

Gross Beta Reguired LLD 0.010 Reguired LLD 0.010 01-05-16 294 0.039 +/- 0.005 07-05-16 300 0.017 +/- 0.004 01-12-16 302 0.024 +/- 0.004 07-12-16 302 0.018 +/- 0.004 01-19-16 300 0.036 +/- 0.005 07-19-16 305 0.016 +/- 0.004 01-26-16 312 0.026 +/- 0.005 07-26-16 301 0.019 +/- 0.004 02-02-16 294 0.021 +/- 0.004 08-02-16 303 0.016 +/- 0.004 02-09-16 300 0.016 +/- 0.005 08-09-16 303 0.020 +/- 0.004 02-16-16 302 0.015 +/- 0.004 08-16-16 305 0.024 +/- 0.004 02-23-16 303 0.011 +/- 0.004 08-23-16 300 0.020 +/- 0.004 03-01-16 302 0.024 +/- 0.004 08-30-16 305 0.020 +/- 0.004 03-08-16 311 0.020 +/- 0.004 09-06-16 302 0.018 +/- 0.004 03-15-16 293 0.021 +/- 0.005 09-13-16 301 0.012 +/- 0.004 03-22-16 304 0.013 +/- 0.004 09-20-16 169 0.016 +/- 0.006 b

03-29-16 302 0.025 +/- 0.004 09-27-16 256 0.020 +/- 0.005 c

1st Quarter Mean+/- s.d.

0.022 +/- 0.008 3rd Quarter Mean +/- s.d.

0.018 +/- 0.003 04-05-16 302 0.022 +/- 0.004 10-04-16 304 0.015 +/- 0.004 04-12-16 304 0.015 +/- 0.004 10-11-16 300 0.022 +/- 0.004 04-19-16 304 0.018 +/- 0.004 10-18-16 305 0.025 +/- 0.004 04-26-16 301 0.015 +/- 0.004 10-25-16 300 0.015 +/- 0.004 05-03-16 299 0.014 +/- 0.004 11-01-16 302 0.017 +/- 0.004 05-10-16 241 0.004 +/- 0.004 11-08-16 306 0.038 +/- 0.005 05-17-16 304 0.012 +/- 0.004 11-15-16 300 0.019 +/- 0.004 05-24-16 301 0.021 +/- 0.004 11-22-16 303 0.045 +/- 0.005 05-31-16 303 0.017 +/- 0.004 11-29-16 304 0.030 +/- 0.004 06-07-16 302 0.011 +/- 0.003 12-06-16 301 0.027 +/- 0.004 06-14-16 302 0.015 +/- 0.004 12-13-16 303 0.022 +/- 0.004 06-21-16 304 0.016 +/- 0.004 12-20-16 303 0.030 +/- 0.005 06-28-16 303 0.013 +/- 0.004 12-27-16 302 0.027 +/- 0.004 01-03-17 302 0.030 +/- 0.004 2nd Quarter Mean +/- s.d.

0.015 +/- 0.005 4th Quarter Mean +/- s.d.

0.026 +/- 0.009 Cumulative Average 0.020 a lodine-131 concentrations are< 0.03 pCi/m3 unless otherwise noted.

b Sample pump found not running 9/20/16.

c Sample pump replaced 9/21/16.

23

KPS Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131°.

Location:

K-31 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3)

Gross Beta Collected (m3)

Gross Beta Reguired LLD 0.010 Reguired LLD 0.010 01-05-16 295 0.040 +/- 0.005 07-05-16 300 0.015 +/- 0.004 01-12-16 299 0.020 +/- 0.004 07-12-16 302 0.019 +/- 0.004 01-19-16 306 0.029 +/- 0.005 07-19-16 303 0.017 +/- 0.004 01-26-16 305 0.026 +/- 0.005 07-26-16 303 0.018 +/- 0.004 02-02-16 301 0.023 +/- 0.004 08-02-16 304 0.015 +/- 0.004 02-09-16 302 0.016 +/- 0.005 08-09-16 301 0.019 +/- 0.004 02-16-16 303 0.017 +/- 0.004 08-16-16 262 0.025 +/- 0.005 02-23-16 302 0.012 +/- 0.004 08-23-16 189 0.020 +/- 0.006 03-01-16 304 0.021 +/- 0.004 08-30-16 304 0.018 +/- 0.004 03-08-16 301 0.016 +/- 0.004 09-06-16 302 0.021 +/- 0.004 03-15-16 301 0.017 +/- 0.004 09-13-16 301 0.017 +/- 0.004 03-22-16 297 0.017 +/- 0.004 09-20-16 305 0.027 +/- 0.004 03-29-16 302 0.024 +/- 0.004 09-27-16 300 0.019 +/- 0.004 1st Quarter Mean+/- s.d.

0.021 +/- 0.007 3rd Quarter Mean+/- s.d.

0.019 +/- 0.003 04-05-16 303 0.024 +/- 0.004 10-04-16 304 0.016 +/- 0.004 04-12-16 304 0.014 +/- 0.004 10-11-16 299 0.019 +/- 0.004 04-19-16 304 0.019 +/- 0.004 10-18-16 302 0.030 +/- 0.004 04-26-16 301 0.017 +/- 0.004 10-25-16 303 0.018 +/- 0.004 05-03-16 299 0.013 +/- 0.004 11-01-16 303 0.016 +/- 0.004 05-10-16 291 0.008 +/- 0.004 11-08-16 305 0.031 +/- 0.005 05-17-16 313 0.015 +/- 0.004 11-15-16 307 0.026 +/- 0.004 05-24-16 293 0.019 +/- 0.004 11-22-16 301 0.038 +/- 0.005 05-31-16 303 0.017 +/- 0.004 11-29-16 304 0.029 +/- 0.004 06-07-16 303 0.013 +/- 0.003 12-06-16 296 0.021 +/- 0.004 06-14-16 301 0.011 +/- 0.004 12-13-16 303 0.016 +/- 0.004 06-21-16 302 0.020 +/- 0.004 12-20-16 303 0.029 +/- 0.004 06-28-16 305 0.012 +/- 0.004 12-27-16 308 0.025 +/- 0.004 01-03-17 305 0.029 +/- 0.004 2nd Quarter Mean +/- s.d.

0.016 +/- 0.004 4th Quarter Mean +/- s.d.

0.025 +/- 0.007 Cumulative Average 0.020 a lodine-131 concentrations are< 0.03 pCi/m3 unless otherwise noted.

24

KPS Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131°.

Location: K-41 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ms)

Gross Beta Collected (ms)

Gross Beta Reguired LLD 0.010 Reguired LLD 0.010 01-05-16 294 0.036 +/- 0.005 07-05-16 300 0.017 +/- 0.004 01-12-16 303 0.023 +/- 0.004 07-12-16 302 0.021 +/- 0.004 01-19-16 304 0.036 +/- 0.005 07-19-16 306 0.015 +/- 0.004 01-26-16 303 0.029 +/- 0.005 07-26-16 300 0.021 +/- 0.004 02-02-16 302 0.024 +/- 0.004 08-02-16 303 0.014 +/- 0.004 02-09-16 302 0.016 +/- 0.005 08-09-16 301 0.020 +/- 0.004 02-16-16 304 0.018 +/- 0.004 08-16-16 281 0.023 +/- 0.005 02-23-16 302 0.016 +/- 0.005 08-23-16 155 0.021 +/- 0.007 03-01-16 303 0.024 +/- 0.004 08-30-16 304 0.020 +/- 0.004 03-08-16 302 0.019 +/- 0.004 09-06-16 302 0.020 +/- 0.004 03-15-16 300 0.017 +/- 0.004 09-13-16 304 0.015 +/- 0.004 03-22-16 302 0.012 +/- 0.004 09-20-16 302 0.024 +/- 0.004 03-29-16 301 0.023 +/- 0.004 09-27-16 300 0.024 +/- 0.004 1st Quarter Mean +/- s.d.

0.023 +/- 0.007 3rd Quarter Mean +/- s.d.

0.020 +/- 0.003 04-05-16 303 0.022 +/- 0.004 10-04-16 304 0.015 +/- 0.004 04-12-16 305 0.015 +/- 0.004 10-11-16 300 0.022 +/- 0.004 04-19-16 304 0.019 +/- 0.004 10-18-16 307 0.024 +/- 0.004 04-26-16 303 0.018 +/- 0.004 10-25-16 298 0.013 +/- 0.004 05-03-16 299 0.011 +/- 0.004 11-01-16 307 0.017 +/- 0.004 05-10-16 342 0.013 +/- 0.004 11-08-16 301 0.034 +/- 0.005 05-17-16 305 0.012 +/- 0.004 11-15-16 304 0.022 +/- 0.004 05-24-16 300 0.018 +/- 0.004 11-22-16 301 0.033 +/- 0.005 05-31-16 303 0.017 +/- 0.004 11-29-16 304 0.027 +/- 0.004 06-07-16 303 0.012 +/- 0.003 12-06-16 297 0.026 +/- 0.004 06-14-16 302 0.016 +/- 0.004 12-13-16 302 0.017 +/- 0.004 06-21-16 305 0.017 +/- 0.004 12-20-16 303 0.029 +/- 0.004 06-28-16 303 0.013 +/- 0.004 12-27-16 305 0.024 +/- 0.004 01-03-17 303 0.024 +/- 0.004 2nd Quarter Mean +/- s.d.

0.016 +/- 0.003 4th Quarter Mean +/- s.d.

0.023 +/- 0.006 Cumulative Average 0.020 a lodine-131 concentrations are< 0.03 pCi/m 3 unless otherwise noted.

25

KPS Table 9. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: K-43 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m:.)

Gross Beta Collected (m:.)

Gross Beta Reguired LLD 0.010 Reguired LLD 0.010 01-05-16 294 0.036 +/- 0.005 07-05-16 300 0.013 +/- 0.004 01-12-16 302 0.018 +/- 0.004 07-12-16 302 0.015 +/- 0.004 01-19-16 301 0.031 +/- 0.005 07-19-16 305 0.015 +/- 0.004 01-26-16 311 0.026 +/- 0.005 07-26-16 300 0.016 +/- 0.004 02-02-16 302 0.018 +/- 0.004 08-02-16 303 0.014 +/- 0.004 02-09-16 302 0.014 +/- 0.004 08-09-16 301 0.016 +/- 0.004 02;16-16 302 0.013 +/- 0.004 08-16-16 305 0.027 +/- 0.004 02-23-16 303 0.012 +/- 0.004 08-23-16 300 0.023 +/- 0.004 03-01-16 302 0.020 +/- 0.004 08-30-16 304 0.021 +/- 0.004 03-08-16 311 0.016 +/- 0.004 09-06-16 303 0.022 +/- 0.004 03-15-16 293 0.014 +/- 0.004 09-13-16 301 0.019 +/- 0.004 03-22-16 304 0.011 +/- 0.004 09-20-16 302 0.026 +/- 0.004 03-29-16 302 0.018 +/- 0.004 09-27-16 303 0.022 +/- 0.004 1st Quarter Mean +/- s.d.

0.019 +/- 0.008 3rd Quarter Mean +/- s.d.

0.019 +/- 0.005 04-05-16 302 0.016 +/- 0.004 10-04-16 304 0.020 +/- 0.004 04-12-16 304 0.011 +/- 0.004 10-11-16 300 0.022 +/- 0.004 04-19-16 304 0.017 +/- 0.004 10-18-16 305 0.028 +/- 0.004 04-26-16 301 0.014 +/- 0.004 10-25-16 300 0.014 +/- 0.004 05-03-16 299 0.010 +/- 0.004 11-01-16 302 0.015 +/- 0.004 05-10-16 257 0.005 +/- 0.004 11-08-16 306 0.038 +/- 0.005 05-17-16 304 0.014 +/- 0.004 11-15-16 300 0.022 +/- 0.004 05-24-16 301 0.014 +/- 0.004 11-22-16 303 0.044 +/- 0.005 05-31-16 303 0.016 +/- 0.004 11-29-16 304 0.031 +/- 0.005 06-07-16 302 0.013 +/- 0.003 12-06-16 301 0.028 +/- 0.004 06-14-16 302 0.013 +/- 0.004 12-13-16 303 0.016 +/- 0.004 06-21-16 304 0.015 +/- 0.004 12-20-16 303 0.026 +/- 0.004 06-28-16 303 0.012 +/- 0.004 12-27-16 302 0.025 +/- 0.004 01-03-17 302 0.031 +/- 0.004 2nd Quarter Mean +/- s.d.

0.013 +/- 0.003 4th Quarter Mean +/- s.d.

0.026 +/- 0.009 Cumulative Average 0.019 a lodine-131 concentrations are< 0.03 pCi/m 3 unless otherwise noted.

26

KPS Table 10. Airborne particulate data, gross beta analyses, monthly averages, minima and maxima.

January April Location Average Minima Maxima Location Average Minima Maxima Indicators 0.030 0.018 0.040 Indicators 0.016 0.010 0.025 K-1f 0.033 0.026 0.040 K-1f 0.018 0.012 0.025 K-43 0.026 0.018 0.036 K-43 0.014 0.010 0.017 Controls 0.029 0.018 0.045 Controls 0.017 0.012 0.024 K-2 0.030 0.018 0.045 K-2 0.016 0.012 0.020 K-8 0.029 0.021 0.039 K-8 0.017 0.014 0.022 K-31 0.028 0.020 0.040 K~31 0.017 0.013 0.024 K-41 0.030 0.023 0.036 K-41 0.017 0.013 0.024 February May Location Average Minima Maxima Location Average Minima Maxima Indicators 0.018 0.012 0.025 Indicators 0.015 0.004 0.030 K-1f 0.020 0.016 0.025 K-1f 0.019 0.009 0.029 K-43 0.015 0.012 0.020 K-43 0.012 0.005 0.016 Controls 0.018 0.011 0.024 Controls 0.014 0.004 0.021 K-2 0.017 0.011 0.024 K-2 0.013 0.005 0.019 K-8 0.017 0.011 0.024 K-8 0.014 0.004 0.021 K-31 0.017 0.012 0.021 K-31 0.015 0.008 0.019 K-41 0.019 0.016 0.024 K-41 0.015 0.012 0.018 March June Location Average Minima Maxima Location Average Minima Maxima Indicators 0.018 0.011 0.029 Indicators 0.015 0.012 0.019 K-1f 0.021 0.013 0.029 K-1f 0.016 0.012 0.019 K-43 0.015 0.011 0.018 K-43 0.013 0.012 0.015 Controls 0.019 0.012 0.025 Controls 0.017 0.009 0.030 K-2 0.017 0.014 0.020 K-2 0.012 0.009 0.014 K-8 0.020 0.013 0.025 K-8 0.014 0.011 0.016 K-31 0.019 0.016 0.024 K-31 0.014 0.011 0.020 K-41 0.018 0.012 0.023 K-41 0.015 0.012 0.017 Note: Samples collected on the first, second or third day of the month are grouped with data of the previous month.

27

KPS Table 10. Airborne particulate data, gross beta analyses, monthly averages, minima and maxima.

July October Location Average Minima Maxima Location Average Minima Maxima Indicators 0.017 0.013.

0.021 Indicators 0.020 0.014 0.028 K-1f 0.019 0.016 0.021 K-1f 0.020 0.015 0.027 K-43 0.015 0.013 0.016 K-43 0.020 0.014 0.028 Controls 0.018 0.014 0.021 Controls 0.019 0.013 0.030 K-2 0.018 0.016 0.019 K-2 0.019 0.015 0.029 K-8 0.017 0.016 0.019 K-8 0.019 0.015 0.025 K-31 0.017 0.015 0.019 K-31 0.020 0.016 0.030 K-41 0.018 0.014 0.021 K-41 0.018 0.013 0.024 August November Location Average Minima Maxima Location Average Minima Maxima Indicators 0.022 0.016 0.027 Indicators 0.033 0.020 0.044 K-1f 0.022 0.018 0.027 K-1f 0.032 0.020 0.041 K-43 0.022 0.016 0.027 K-43 0.034 0.022 0.044 Controls 0.021 0.018 0.025 Controls 0.031 0.019 0.045 K-2 0.021 0.019 0.025 K-2 0.029 0.021 0.034 K-8 0.021 0.020 0.024 K-8 0.033 0.019 0.045 K-31 0.021 0.018 0.025 K-31 0.031 0.026 0.038 K-41 0.021 0.020 0.023 K-41 0.029 0.022 0.034 September December Location Average Minima Maxima Location Average Minima Maxima Indicators 0.022 0.017 0.027 Indicators 0.025 0.016 0.031 K-1f 0.021 0.017 0.027 K-1f 0.025 0.019 0.031 K-43 0.022 0.019 0.026 K-43 0.024 0.016 0.028 Controls 0.020 0.012 0.027 Controls 0.024 0.016 0.030 K-2 0.019 O.D15 0.022 K-2 0.023 0.018 0.027 K-8 0.017 0.012 0.020 K-8 0.027 0.022 0.030 K-31 0.021 0.017 0.027 K-31 0.023 0.016 0.029 K-41 0.021 0.015 0.024 K-41 0.024 0.017 0.029 Note: Samples collected on the first, second or third day of the month are grouped with data of the previous month.

28

KPS Table 11. Airborne particulate samples, quarterly composites of weekly samples, analysis for gamma-emitting isotopes.

Sample Description and Concentration (pCi/m3) 1st Quarter 2nd Quarter 3rd Quarter Indicator K-1f Lab Code KAP-1724 KAP-3832 KAP-5678 Volume (m3) 3920 3931 3855 Be-7 0.059 +/- 0.014 0.092 +/- 0.017 0.085 +/- 0.023 Nb-95

< 0.0009

< 0.0019

< 0.0012 Zr-95

< 0.0015

< 0.0019

< 0.0012 Ru-103

< 0.0009

< 0.0006

< 0.0010 Ru-106

< 0.0081

< 0.0096

< 0.0097 Cs-134

< 0.0009

< 0.0009

< 0.0009 Cs-137

< 0.0006

< 0.0007

< 0.0004 Ce-141

< 0.0017

< 0.0019

< 0.0021 Ce-144

< 0.0033

< 0.0029

< 0.0031 K-43 Lab Code KAP-1729 KAP-3837 KAP-5684 Volume (m3) 3929 3886 3929 Be-7 0.045 +/- 0.012 0.085 +/- 0.014 0.082 +/- 0.020 Nb-95

< 0.0008

< 0.0008

< 0.0014 Zr-95

< 0.0015

< 0.0011

< 0.0017 Ru-103

< 0.0010

< 0.0011

< 0.0011 Ru-106

< 0.0044

< 0.0025

< 0.0055 Cs-134

< 0.0007

< 0.0008

< 0.0009 Cs-137

< 0.0005

< 0.0003

< 0.0006 Ce-141

< 0.0010

< 0.0015

< 0.0029 Ce-144

< 0.0022

< 0.0023

< 0.0033 29 4th Quarter KAP-7177 4235 0.050 +/- 0.013

< 0.0010

< 0.0014

< 0.0011

< 0.0051

< 0.0008

< 0.0008

< 0.0013

< 0.0037 KAP-7183 4235 0.056 +/- 0.014

< 0.0010

< 0.0015

< 0.0011

< 0.0066

< 0.0007

< 0.0007

< 0.0018

< 0.0031

KPS Table 11. Airborne particulate samples, quarterly composites of weekly samples, analysis for gamma-emitting isotopes, (continued).

Sample Description and Concentration (pCi/m3) 1st Quarter 2nd Quarter 3rd Quarter Control K-2 Lab Code KAP-1725 KAP-3833 KAP-5679 Volume (m3) 3911 3586 3886 Be-7 0.070 +/- 0.022 0.084 +/- 0.018 0.093 +/- 0.016 Nb-95

< 0.0012

< 0.0017

< 0.0016 Zr-95

< 0.0016

< 0.0016

< 0.0020 Ru-103

< 0.0009

< 0.0015

< 0.0012 Ru-106

< 0.0079

< 0.0090

< 0.0030 Cs-134

< 0.0010

< 0.0011

< 0.0006 Cs-137

< 0.0009

< 0.0011

< 0.0006 Ce-141

< 0.0011

< 0.0028

< 0.0018 Ce-144

< 0.0053

< 0.0050

< 0.0029 K-8 Lab Code KAP-1726 KAP-3834 KAP-5680 Volume (m3) 3919 3870 3752 Be-7 0.058 +/- 0.014 0.091 +/- 0.015 0.060 +/- 0.012 Nb-95

< 0.0010

< 0.0011

< 0.0009 Zr-95

< 0.0020

< 0.0014

< 0.0012 Ru-103

< 0.0014

< 0.0011

< 0.0010 Ru-106

< 0.0078

< 0.0045

< 0.0052 Cs-134

< 0.0009

< 0.0009

< 0.0006 Cs-137

< 0.0007

< 0.0007

< 0.0004 Ce-141

< 0.0021

< 0.0018

< 0.0012 Ce-144

< 0.0039

< 0.0035

< 0.0020 30 4th Quarter KAP-7178 4243 0.047 +/- 0.015

< 0.0009

< 0.0013

< 0.0010

< 0.0074

< 0.0008

< 0.0005

< 0.0011

< 0.0036 KAP-7180 4235 0.048 +/- 0.010

< 0.0011

< 0.0013

< 0.0011

< 0.0055

< 0.0007

< 0.0005

< 0.0013

< 0.0021

KPS Table 11. Airborne particulate samples, quarterly composites of weekly samples, analysis for gamma-emitting isotopes, (continued).

Sample Description and Concentration (pCi/m3) 1st Quarter 2nd Quarter 3rd Quarter Control K-31 Lab Code KAP-1727 KAP-3835 KAP-5681 Volume (m3) 3918 3922 3776 Be-7 0.057 +/- 0.016 0.088 +/- 0.017 0.079 +/- 0.019 Nb-95

< 0.0014

< 0.0013

< 0.0024 Zr-95

< 0.0023

< 0.0017

< 0.0016 Ru-103

< 0.0012

< 0.0010

< 0.0014 Ru-106

< 0.0068

< 0.0061

< 0.0078 Cs-134

< 0.0009

< 0.0008

< 0.0011 Cs-137

< 0.0010

< 0.0007

< 0.0006 Ce-141

< 0.0021

< 0.0022

< 0.0026 Ce-144

< 0.0052

< 0.0037

< 0.0030 K-41 Lab Code KAP-1728 KAP-3836 KAP-5683 Volume (m3) 3922 3977 3760 Be-7 0.056 +/- 0.012 0.080 +/- 0.017 0.082 +/- 0.018 Nb-95

< 0.0007

< 0.0024

< 0.0012 Zr-95

< 0.0012

< 0.0015

< 0.0014 Ru-103

< 0.0011

< 0.0019

< 0.0013 Ru-106

< 0.0045

< 0.0080

< 0.0076 Cs-134

< 0.0009

< 0.0011

< 0.0008 Cs-137

< 0.0008

< 0.0008

< 0.0009 Ce-141

< 0.0016

< 0.0025

< 0.0025 Ce-144

< 0.0034

< 0.0039

< 0.0038 31 4th Quarter KAP-7181 4243 0.051 +/- 0.015

< 0.0012

< 0.0009

< 0.0011

< 0.0032

< 0.0008

< 0.0005

< 0.0014

< 0.0046 KAP-7182 4236 0.050 +/- 0.016

< 0.0018

< 0.0016

< 0.0008

< 0.0066

< 0.0011

< 0.0009

< 0.0015

< 0.0045

32

Table 13.

Date Collected 01/04/16 02/01/16 03/01/16 04/04/16 05/02/16 06/01/16 07/05/16 08/01/16 09/06/16 10/03/16 11/01/16 12/01/16 KPS Precipitation samples collected at Location K-11; analysis for tritium.

Lab Code KP-104 KP-451 KP-843 KP-1343 KP-2096 KP-2748 KP-3348 KP-4040 KP-4709 KP-5177 KP-5986 KP-6607 H-3 pCi/L T.U. (100 T.U. = 320 pCi/L)

< 145

<45

< 148

<46

< 155

<48

< 152

<48

< 148

<46

< 151

<47

< 146

<46

< 150

<47

< 155

<48

< 157

<49

< 180

< 56

< 180

< 56 33

KPS Table 14.

Milk, analyses for iodine-131 and gamma-emitting isotopes.

Collection: Semimonthly during grazing season, monthly at other times.

Collection Lab Concentration (pCi/L)

Date Code 1-131 Cs-134 Cs-137 Ba-La-140 K-40 Indicators K-5 01-05-16 KMI-2

< 0.2

< 4.4

< 4.4

< 8.5 1463 +/- 135 02-02-16 KMI-435

< 0.2

< 2.9

< 3.7

< 1.9 1300 +/- 100 03-01-16 KMI-846

< 0.3

<4.0

< 3.7

< 2.4 1447+/-109 04-04-16 KMI-1349

< 0.5

< 3.8

< 3.1

< 1.4 1360+/-108 05-03-16 KMI-2075

< 0.5

< 3.3

< 3.3

< 3.2 1394+/-103 05-17-16 KMI-2423

< 0.3

< 4.2

< 3.5

< 1.9 1414+/-112 06-02-16 KMI-2738

< 0.2

< 4.1

< 4.1

< 3.0 1437 +/- 121 06-21-16 KMI-3128

< 0.4

< 3.6

<4.0

< 1.2 1214 +/- 108 07-05-16 KMI-3338

< 0.2

< 3.7

< 3.4

< 2.8 1402 +/- 108 07-19-16 KMI-3713

< 0.2

< 3.0

< 2.9

< 1.6 1402+/-109 08-02-16 KMI-4048

< 0.2

< 4.1

< 3.9

< 9.4 1397 +/- 118 08-16-16 KMlc 4344

< 0.3

< 4.0

< 4.4

<2.3 1333. +/- 114 09-07-16 KMI-4712

< 0.3

< 3.6

< 3.0

< 9.2 1298+/-105 09-20-16 KMI-4928

< 0.4

< 3.6

< 3.5

< 1.5 1311 +/- 112 10-03-16 KMI-5180

< 0.2

< 2.7

< 3.2

< 3.2 1535 +/- 101 10-18-16 KMI-5557

< 0.4

< 3.9

< 2.5

< 2.2 1412 +/- 120 11-02-16 KMI-5994

<0.2

< 3.9

< 3.3

< 6.0 1441+/-111 12-02-16 KMI-6570

< 0.3

< 3.6

< 2.3

< 6.4 1423 +/- 119 K-34 01-04-16 KMI-3

< 0.4

< 6.6

< 3.2

<4.0 1163 +/- 199 02-01-16 KMI-436

< 0.4

< 4.1

< 3.6

< 2.4 1434+/-109 03-01-16 KMI-847

< 0.3

< 3.5

< 3.4

< 1.7 1492+/-113 04-04-16 KMI-1350

< 0.5

< 4.0

< 2.7

< 1.3 1473 +/-114 05-02-16 KMI-2076

< 0.3

< 3.1

< 3.5

< 5.5 1390+/-106 05-17-16 KMI-2424

< 0.3

< 3.8

< 2.5

< 1.2 1393 +/- 116 06-01-16 KMI-2739

< 0.4

< 3.7

< 3.3

<2.2 1407 +/- 108 06-21-16 KMI-3129

< 0.2

< 3.5

< 3.5

< 1.4 1396 +/- 110 07-05-16 KMI-3339

< 0.5

< 3.2

< 3.8

< 1.1 1339 +/- 111 07-19-16 KMI-3714

< 0.4

< 3.5

< 2.3

<2.7 1313+/-110 08-01-16 KMI-4049

< 0.2

< 3.6

< 2.5

< 7.3 1423+/-105 08-16-16 KMI-4345

< 0.3

<4.0

< 3.3

<2.3 1361 +/-114 09-06-16 KMI-4713

< 0.3

< 4.7

< 2.7

<4.0 1442+/-127 09-20-16 KMI-4929

< 0.3

< 8.0

< 5.4

<5.6 1354+/-170 10-03-16 KMI-5181

< 0.5

< 2.9

< 3.0

< 11.4 1390 +/- 97 10-18-16 KMI-5558

< 0.4

< 4.1

< 4.1

< 1.6 1499 +/- 120 11-01-16 KMI-5995

< 0.5

< 3.7

< 1.9

< 10.4 1397+/-104 12-01-16 KMI-6571

< 0.4

< 3.6

< 3.0

< 5.1 1433 +/- 115 34

KPS Table 14.

Milk, analyses for iodine-131 and gamma-emitting isotopes (continued).

Collection Lab Concentration (pCi/L)

Date Code 1-131 Cs-134 Cs-137 Ba-La-140 K-40 Indicators K-38 01-05-16 KMI-5

< 0.2

<4.6

< 5.1

< 8.1 1370 +/- 138 02-02-16 KMI-438

< 0.4

< 3.2

< 3.4

<5.3 1486+/-105 03-02-16 KMI-849

< 0.3

< 3.1

< 1.9

<4.5 1315 +/-95 04-05-16 KMI-1352

< 0.2

< 3.0

< 3.0

< 1.4 1472+/-107 05-03-16 KMI-2078

< 0.2

< 3.7

< 3.6

< 5.1 1317+/-110 05-17-16 KMI-2426

< 0.3

< 3.4

< 3.2

<2.2 1377 +/- 116 06-01-16 KMI-2741

< 0.3

< 3.1

< 2.8

< 2.4 1257+/-110 06-21-16 KMI-3131

< 0.2

< 3.4

< 3.0

< 4.1 1412+/-116 07-05-16 KMI-3341

< 0.3

< 4.4

< 3.1

< 3.1 1534 +/- 136 07-19-16 KMI-3716

< 0.3

< 3.4

< 4.1

< 1.9 1413+/-119 08-01-16 KMI-4051

< 0.2

<2.8

< 2.6

< 9.4 1352 +/- 104 08-16-16 KMI-4347

< 0.4

< 5.1

< 4.4

<4.8 1311 +/- 124 09-06-16 KMI-4715

< 0.2

<3.5

< 2.0

< 7.7 1322+/-106 09-20-16 KMI-4931

< 0.2

<3.9

< 3.7

< 2.0 1272 +/- 113 10-03-16 KMI-5183

< 0.4

< 3.7

< 3.6

< 7.9 1439+/-109 10-18-16 KMI-5560

< 0.3

< 6.2

< 7.6

< 1.9 1266+/-154 11-01-16 KMI-5997

< 0.2

< 3.7

< 3.5

< 10.5 1385+/-109 12-01-16 KMI-6573

< 0.3

< 3.0

< 3.6

< 3.7 1350+/-102 K-39 01-05-16 KMI-6

< 0.2

<4.3

< 3.9

< 2.0 1399 +/-121 02-02-16 KMI-439

< 0.2

< 3.6

< 3.5

<4.6 1394+/-104 03-01-16 KMI-850

< 0.4

< 2.7

< 3.0

<2.0 1469 +/- 103 04-04-16 KMI-1353

< 0.2

<2.9

< 3.6

< 1.2 1350 +/- 111 05-02-16 KMI-2079

< 0.2

< 3.5

< 3.8

< 3.6 1370+/-101 05-17-16 KMI-2427

< 0.3

< 8.1

< 9.2

< 4.1 1235+/-174 06-01-16 KMI-2742

< 0.3

< 3.6

< 3.0

<4.2 1384+/-106 06-21-16 KMI-3132

< 0.4

<4.3

< 2.0

< 1.6 1333 +/- 118 07-05-16 KMI-3342

< 0.4

< 3.2

< 3.6

< 3.2 1358+/-104 07-19-16 KMI-3717

< 0.3

<4.5

<4.2

<2.0 1284+/-124 08-02-16 KMI-4052

< 0.2

< 3.9

< 2.7

< 9.2 1317+/-101 08-16-16 KMI-4348

< 0.4

< 4.1

< 2.7

<2.8 1283 +/- 117 09-07-16 KMI-4716

< 0.3

< 3.4

< 3.7

< 9.2 1321 +/- 104 09-20-16 KMI-4932

< 0.5

< 3.7

< 3.6

< 1.5 1301 +/- 108 10-03-16 KMI-5184

< 0.2

< 3.0

< 2.3

< 10.8 1412 +/- 83 10-18-16 KMI-5561

< 0.2

<4.5

< 4.1

< 3.2 1331 +/- 114 11-02-16 KMI-5998

< 0.2

< 3.5

< 2.5

< 15.0 1399 +/- 111 12-02-16 KMI-6574

< 0.4

< 3.6

< 3.9

< 5.3 1374 +/-109 35

KPS Table 14.

Milk, analyses for iodine-131 and gamma-emitting isotopes (continued).

Collection Lab Concentration (pCi/L)

Date Code 1-131 Cs-134 Cs-137 Ba-La-140 K-40 Controls K-3 01-04-16 KMI-1

< 0.2

<7.5

< 8.4

< 7.5 1168 +/- 176 02-01-16 KMI-434

< 0.2

< 3.4

< 3.9

< 1.3 1305 +/- 116 03-01-16 KMI-845

< 0.2

< 3.7

< 4.1

<2.2 1280 +/- 99 04-04-16 KMI-1348

< 0.2

<4.2

< 4.4

< 1.6 1400 +/- 120 05-03-16 KMI-2074

< 0.4

<3.6

< 2.6

< 2.3 1316+/-100 05-17-16 KMI-2422

< 0.5

< 5.9

< 5.4

< 1.8 1320+/-143 06-02-16 KMI-2737

< 0.2

< 3.1

< 2.7

< 1.7 1367 +/- 98 06-21-16 KMI-3127

< 0.2

<4.1

< 3.9

< 1.7 1409 +/-119 07-06-16 KMI-3337

< 0.2

<4.6

< 4.9

<2.5 1311 +/- 120 07-19-16 KMI-3712

< 0.3

< 3.7

<4.2

< 1.9 1421+/-114 08-01-16 KMI-4047

< 0.2

< 3.9

< 3.9

< 11.0 1394+/-106 08-16-16 KMI-4343

< 0.3

< 3.6

< 2.8

<4.0 1489 +/- 123 09-06-16 KMI-4711

< 0.3

< 5.1

< 3.6

< 3.8 1454 +/- 129 09-20-16 KMI-4927

< 0.2

<4.3

< 4.4

< 2.4 1487 +/-116 10-03-16 KMI-5179

< 0.5

<4.6

< 3.0

< 5.1 1288 +/- 124 10-18-16 KMI-5556

< 0.2

<4.3

< 3.2

< 1.4 1426 +/- 130 11-01-16 KMI-5993

< 0.2

<3.3

<4.3

< 5.1 1429 +/- 111 12-01-16 KMI-6569

< 0.3

<4.0

<2.5

< 3.8 1325+/-121 K-35 01-05-16 KMI-4

< 0.5

<3.8

<2.5

< 5.4 1377 +/-116 02-02-16 KMI-437

< 0.4

< 3.3

< 3.1

< 3.2 1339+/-103 03-02-16 KMI-848

< 0.4

< 3.4

< 3.8

< 1.9 1462+/-106 04-05-16 KMI-1351

< 0.4

<3.5

< 2.2

< 1.3 1378 +/-112 05-03-16 KMI-2077

< 0.2

<4.5

<4.5

< 7.6 1483 +/- 121 05-17-16 KMI-2425

< 0.3

<3.6

<2.9

< 1.9 1375+/-116 06-01-16 KMI-2740

< 0.4

< 3.9

< 3.4

< 2.9 1227 +/-101 06-21-16 KMI-3130

< 0.2

<4.5

<4.7

< 3.6 1425+/-130 07-06-16 KMI-3340

< 0.3

< 2.9

<4.0

< 2.0 1405+/-117 07-19-16 KMI-3715

< 0.2

< 3.5

< 3.8

< 2.7 1404+/-108 08-02-16 KMI-4050

< 0.2

< 3.5

< 3.3

< 8.3 1326+/-106 08-16-16 KMI-4346

< 0.5

< 7.0

< 5.7

< 2.6 1479+/-179 09-07-16 KMI-4714

< 0.3

< 3.8

<2.8

< 11.6 1505+/-114 09-20-16 KMI-4930

< 0.3

< 5.2

<4.3

< 2.0 1437 +/- 121 10-04-16 KMI-5182

< 0.4

< 1.4

< 1.6

< 8.1 1408 +/-43 10-18-16 KMI-5559

< 0.4

< 3.3

< 3.7

< 3.3 1360+/-122 11-02-16 KMI-5996

< 0.2

<3.3

< 3.3

< 10.4 1367+/-108 12-01-16 KMI-6572

< 0.4

< 3.9

<4.6

<5.3 1366+/-114 36

KPS Table 14.

Milk, analyses for iodine-131 and gamma-emitting isotopes (continued).

Collection Lab Concentration (pCi/L)

Date Code 1-131 Cs-134 Cs-137 Ba-La-140 K-40 Control K-42 01-04-16 KMI-7

< 0.2

< 4.9

< 3.9

< 9.1 1369 +/- 124 02-01-16 KMI-440

< 0.2

< 3.6

< 2.7

<2.2 1415+/-112 03-01-16 KMI-851

< 0.5

< 3.0

< 3.7

<2.9 1315 +/- 95 04-04-16 KMI-1354

< 0.2

< 4.1

< 3.4

<2.3 1394 +/- 121 05-02-16 KMI-2080

<0.2

< 3.0

< 3.5

< 7.7 1411 +/- 110 05-17-16 KMI-2428

<0.3

< 3.9

< 2.7

< 1.2 1421 +/- 103 06-01-16 KMI-2743

< 0.2

< 2.8

< 3.4

< 2.9 1261 +/- 95 06-21-16 KMI-3133

< 0.2

< 3.7

< 2.3

< 2.4 1316+/-110 07-05-16 KMI-3343

< 0.4

< 3.8

< 3.8

< 3.2 1347+/-117 07-19-16 KMI-3718

< 0.3

< 3.9

< 3.7

< 1.9 1341 +/- 121 08-01-16 KMI-4053

< 0.2

< 3.7

< 3.5

< 9.4 1358 +/- 110 08-16-16 KMI-4349

< 0.4

< 5.0

< 3.5

<2.7 1356+/-125 09-06-16 KMI-4717

< 0.3

< 3.2

< 2.5

< 13.1 1308 +/- 96 09-20-16 KMI-4933

< 0.3

< 7.5

< 6.2

<4.9 1311 +/-160 10-03-16 KMI-5185

< 0.2

< 1.6

< 1.9

< 5.6 1373 +/- 45 10-18-16 KMI-5562

< 0.2

< 3.5

< 3.1

< 3.1 1345 +/- 108 11-01-16 KMI-5999

< 0.2

< 3.3

< 2.9

< 5.7 1379+/-105 12-01-16 KMI-6575

< 0.3

< 3.9

< 3.9

< 5.2 1320 +/- 108 37

KPS Table 15.

Milk, analyses for strontium-89, strontium-90, stable potassium, stable calcium, and ratios of strontium-90 per gram of calcium and cesium-137 per gram of potassium.

Collection: Monthly composites.

Concentration Ratios Collection Lab Sr-89 Sr-90 K

Ca Sr-90per Cs-137 per Period Code (pCi/L)

(pCi/L)

(g/L)

(g/L) gram Ca gram K Indicators K-5 January KMI -2

< 1.2

< 0.5 1.78 +/- 0.16 0.92

< 0.54

< 5.62 February KMI -435

< 1.5

< 0.7 1.59 +/- 0.12 1.03

< 0.68

< 6.29 March KMI -846

< 1.0

< 0.6 1.76 +/-0.13 1.08

< 0.56

< 5.68 April KMI - 1349

< 1.0 0.7 +/- 0.3 1.66 +/- 0.13 1.00 0.70

< 6.02 May KMI -2820

< 0.9

< 0.6 1.71 +/-0.13 0.96

< 0.63

< 5.85 June KMI -3640

< 0.7

< 0.6 1.62 +/- 0.14 1.03

< 0.58

< 6.17 July KMI -3995

< 0.7

< 0.5 1.71 +/-0.13 0.94

< 0.53

<5.85 August KMI -4563

< 0.9 0.7 +/- 0.4 1.66+/-0.14 0.95 0.74

< 6.02 September KMI -5027

< 0.7

< 0.7 1.59 +/- 0.13 0.94

< 0.74

< 6.29 October KMI - 5968

< 1.1

< 0.8 1.80 +/- 0.13 0.90

< 0.89

< 5.56 November KMI - 5994

< 1.0

< 0.5 1.76 +/-0.14 0.90

< 0.56

< 5.68 December KMI -6570

< 0.9 0.7 +/- 0.3 1.74 +/-0.15 0.95 0.74

< 5.75 K-34 January KMI -3

< 0.9 0.8 +/- 0.4 1.42 +/- 0.24 0.92 0.87

< 7.04 February KMI -436

< 1.2 0.6 +/- 0.3 1.75 +/-0.13 1.00 0.60

< 5.71 March KMI -847

< 0.9

< 0.6 1.82 +/- 0.14 0.98

< 0.61

< 5.49 April KMI - 1350

< 0.8

< 0.5 1.80 +/- 0.14 0.99

< 0.51

< 5.56 May KMI - 2821

< 0.7 0.9 +/- 0.3 1.70 +/- 0.14 1.11 0.81

< 5.88 June KMI - 3641

< 0.7

< 0.6 1.71 +/- 0.13 0.87

< 0.69

< 5.85 July KMI -3996

< 0.6 0.5 +/- 0.3 1.62 +/- 0.13 1.00 0.50

< 6.17 August KMI -4564

< 0.6

< 0.5 1.70 +/-0.13 0.95

< 0.53

< 5.88 September KMI -5028

< 0.6 0.7 +/- 0.4 1.70 +/-0.18 0.94 0.74

< 5.88 October KMI -5969

< 0.6 0.5 +/- 0.3 1.76 +/-0.13 0.96 0.52

< 5.68 November KMI -5995

< 0.9 0.8 +/- 0.3 1.70 +/- 0.13 1.02 0.78

< 5.88 December KMI - 6571

< 0.9 0.7 +/- 0.4 1.75 +/-0.14 0.90 0.78

< 5.71 38

KPS Table 15. Milk, analyses for strontium-89, strontium-90, stable potassium, stable calcium, and ratios of strontium-90 per gram of calcium and cesium-137 per gram of potassium (continued).

Concentration Ratios Collection Lab Sr-89 Sr-90 K

Ca Sr-90 per Cs-137 per Period Code (pCi/L)

(pCi/L)

(g/L)

(g/L) gram Ca gram K Indicators K-38 January KMI -5

< 0.7 0.6 +/- 0.3 1.67 +/- 0.17 1.03 0.58

< 5.99 February KMI -438

< 0.8

< 0.6 1.81 +/- 0.13 0.98

< 0.61

< 5.52 March KMI - 849

< 0.9 0.7 +/- 0.4 1.60 +/-0.12 0.93 0.75

< 6.25 April KMI - 1352

< 0.8 0.5 +/- 0.3 1.80 +/-0.13 1.05 0.48

< 5.56 May KMI -2823

< 0.7 0.9 +/- 0.4 1.64 +/-0.14 0.99 0.91

< 6.10 June KMI -3643

< 0.6 0.6 +/- 0.3 1.63 +/- 0.14 0.98 0.61

< 6.13 July KMI -3998

< 0.6 0.8 +/- 0.3 1.80 +/-0.16 1.03 0.78

< 5.56 August KMI -4566

< 0.6 0.9 +/- 0.3 1.62 +/- 0.14 0.95 0.95

< 6.17 September KMI - 5030

< 0.9

< 0.9 1.58 +/- 0.13 1.00

< 0.90

< 6.33 October KMI - 5971

< 0.6 0.6 +/- 0.3 1.65 +/-0.16 1.05 0.57

< 6.06 November KMI - 5997

< 0.9

< 0.5 1.69 +/- 0.13 0.98

< 0.51

< 5.92 December KMI -6573

< 1.0 0.7 +/- 0.4 1.65 +/- 0.12 1.04 0.67

< 6.06 K-39 January KMI -6

< 0.9

< 0.6 1.71 +/-0.15 1.11

< 0.54

< 5.85 February KMI -439

< 0.8

< 0.6 1.70+/-0.13 1.06

< 0.57

< 5.88 March KMI - 850

< 1.1 0.8 +/- 0.4 1.79 +/-0.13 0.99 0.81

< 5.59 April KMI - 1353

< 0.9

< 0.6 1.65 +/-0.14 1.08

< 0.56

< 6.06 May KMI -2824

< 0.7

< 0.5 1.59 +/- 0.17 1.07

< 0.47

< 6.29 June KMI - 3644

< 0.7

< 0.6 1.66 +/- 0.14 1.03

< 0.58

< 6.02 July KMI - 3999

< 0.7 0.8 +/- 0.4 1.61 +/-0.14 0.99 0.81

< 6.21 August KMI -4567

< 0.9 0.9 +/- 0.4 1.59 +/-0.13 0.88 1.02

< 6.29 September KMI - 5031

< 0.7

< 0.7 1.60 +/- 0.13 0.98

< 0.71

< 6.25 October KMI -5972

< 0.7

< 0.5 1.67 +/-0.12 0.94

< 0.53

< 5.99 November KMI -5998

< 0.9

< 0.5 1.71 +/-0.14 1.02

< 0.49

< 5.85 December KMI - 6574

< 1.0

< 0.7 1.68 +/- 0.13 0.98

< 0.71

< 5.95 39

KPS Table 15. Milk, analyses for strontium-89, strontium-90, stable potassium, stable calcium, and ratios of strontium-90 per gram of calcium and cesium-137 per gram of potassium (continued).

Concentration Ratios Collection Lab Sr-89 Sr-90 K

Ca Sr-90 per Cs-137 per Period Code (pCi/L)

(pCi/L)

(g/L)

(g/L) gram Ca gram K Control K-3 January KMI -1

< 0.8 0.8 +/- 0.3 1.42 +/- 0.21 0.97 0.82

< 7.04 February KMI -434

< 1.0 0.7 +/- 0.4 1.59 +/- 0.14 1.00 0.70

< 6.29 March KMI -845

< 1.3 0.7 +/- 0.3 1.56 +/- 0.12 1.08 0.65

< 6.41 April KMI - 1348

< 1.0

< 0.6 1.71 +/-0.15 1.01

< 0.59

< 5.85 May KMI - 2819

< 0.8 1.0 +/- 0.4 1.61 +/- 0.15 0.98 1.02

< 6.21 June KMI -3639

< 0.7

< 0.6 1.69 +/- 0.13 0.99

< 0.61

< 5.92 July KMI -3994

< 0.7 0.8 +/- 0.4 1.67 +/- 0.14 1.00 0.80

< 5.99 August KMI -4562

< 0.8 0.8 +/- 0.3 1.76 +/-0.14 0.97 0.82

< 5.68 September KMI -5026

< 0.7 0.7 +/- 0.3 1.79 +/- 0.15 0.93 0.75

< 5.59 October KMI -5967

< 0.7

< 0.5 1.65 +/- 0.15 0.92

< 0.54

<6.06 November KMI - 5993

< 1.0 0.8 +/- 0.3 1.74 +/-0.14 0.95 0.84

< 5.75 December KMI -6569

< 0.9 1.0 +/- 0.4 1.62 +/- 0.15 0.99 1.01

< 6.17 K-35 January KMI -4

< 1.0

< 0.6 1.68 +/-0.14 0.95

< 0.63

< 5.95 February KMI -437

< 0.9

< 0.6 1.63 +/- 0.13 1.07

< 0.56

< 6.13 March KMI - 848

< 0.9 0.6 +/- 0.3 1.78 +/-0.13 1.10 0.55

< 5.62 April KMI -1351

< 0.8

< 0.5 1.68 +/-0.14 1.01

< 0.50

< 5.95 May KMI -2822

< 0.7

< 0.5 1.74 +/-0.14 1.00

< 0.50

< 5.75 June KMI -3642

< 0.7

< 0.6 1.62 +/- 0.14 0.95

< 0.63

< 6.17 July KMI -3997

< 0.6 0.5 +/- 0.3 1.71 +/- 0.14 0.94 0.53

< 5.85 August KMI -4565

< 0.7 0.5 +/- 0.3 1.71 +/-0.17 0.98 0.51

< 5.85 September KMI - 5029

< 0.6

< 0.5 1.79 +/-0.14 1.01

< 0.50

< 5.59 October KMI - 5970

< 0.7

< 0.5 1.69 +/- 0.10 0.95

<0.53

< 5.92 November KMI - 5996

< 0.9

< 0.5 1.67 +/- 0.13 0.94

< 0.53

< 5.99 December KMI -6572

< 0.9 0.7 +/- 0.3 1.67 +/-0.14 0.90 0.78

< 5.99 K-42 January KMI -7

< 0.9

< 0.6 1.67 +/-0.15 0.89

< 0.67

< 5.99 February KMI -440

< 1.0 0.8 +/- 0.4 1.73 +/-0.14 0.89 0.90

< 5.78 March KMI - 851

< 1.0 0.8 +/- 0.4 1.60 +/-0.12 0.95 0.84

< 6.25 April KMI - 1354

< 1.1

< 0.6 1.70 +/-0.15 0.94

< 0.64

< 5.88 May KMI -2825

< 0.9 0.7 +/- 0.4 1.73 +/-0.13 0.96 0.73

< 5.78 June KMI -3645

< 0.7

< 0.6 1.57 +/- 0.13 0.97

< 0.62

< 6.37 July KMI -4000

< 0.8 0.6 +/- 0.4 1.64 +/-0.14 1.01 0.59

< 6.10 August KMI -4568

< 1.0

< 0.7 1.65 +/-0.14 0.80

< 0.88

< 6.06 September KMI -5032

< 0.8

< 0.7 1.60 +/- 0.13 0.87

< 0.80

< 6.25 October KMI -5973

< 0.8

< 0.6 1.66 +/- 0.13 0.91

< 0.66

< 6.02 November KMI -5999

< 1.6

< 0.6 1.68 +/-0.13 0.90

< 0.67

< 5.95 December KMI -6575

< 0.9

< 0.5 1.61 +/-0.13 0.88

< 0.57

< 6.21 40

Table 16.

Indicator Date Collected Lab Code Gross alpha Gross beta H-3 Sr-89 Sr-90 K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Date Collected Lab Code Gross alpha Gross beta H-3 K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 KPS Well water, analyses for gross alpha, gross beta, tritium, strontium-89", strontium-90",

potassium-40 and gamma-emitting isotopes.

Collection:

Quarterly.

Sample Description and Concentration (pCi/L) 01-04-16 04-04-16 07-05-16 KWW-96 KWW-1367 KWW-3358

< 2.0 5.0 +/- 3.3

< 1.6

< 1.6

< 3.7 3.9 +/- 1.2

< 145

< 148

< 149

< 0.6

< 0.7

<0.7

< 0.5

< 0.4

< 0.4 2.19 2.07 1.44

< 3.3

< 3.4

< 2.1

< 1.8

< 3.2

< 5.4

< 1.2

< 4.0

< 2.6

< 2.4

< 2.9

< 2.6

< 2.3

< 3.4

< 4.0

< 2.3

< 3.5

< 1.5

< 2.9

< 3.9

< 2.7

< 2.8

< 2.5

< 2.5

< 2.1

< 4.2

< 4.3 01-04-16 04-04-16 07-05-16 KWW-97 KWW-1368 KWW-3359 2.7 +/- 1.6

< 4.8

< 1.9 2.9 +/- 1.2

< 3.5 2.9 +/- 1.1

< 145

< 148

< 149 2.36 2.09 2.15

< 3.6

< 3.0

< 1.9

< 3.7

< 5.5

< 2.1

< 2.3

< 4.0

< 0.9

< 2.0

< 3.5

< 1.9

< 5.2

< 5.8

< 1.2

< 2.6

< 5.0

< 2.6

< 3.8

< 3.4

< 1.9

< 3.1

< 2.8

< 1.7

< 3.8

< 6.6

< 2.0 "Strontium analyses required on samples from K-1g only.

41 10-03-16 KWW-5317

< 1.9

< 1.8

< 142

< 0.7

< 0.4 1.67

< 3.0

< 3.3

< 1.7

< 1.8

< 3.8

< 3.4

< 4.3

< 3.2

< 4.8 10-03-16 KWW-5318

< 2.0

< 1.7

< 142 2.28

< 2.8

< 3.4

< 2.4

< 2.6

< 2.5

< 2.1

< 3.0

< 3.4

< 4.8

Table 17.

Indicator Date Collected Lab Code Gross beta H-3 K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Date Collected Lab Code Gross beta H-3 K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 KPS Well water, analyses for gross beta; tritium, potassium-40, and gamma-emitting isotopes.

Collection:

Quarterly.

Sample Description and Concentration (pCi/L) 01-04-16 04-04-16 07-05-16 10-03-16 KWW-98 KWW-1369 KWW-3360 KWW-5319 1.3 +/- 0.8 2.9 +/- 1.4

< 1.0 1.2 +/- 0.3

< 145

< 148

< 149

< 142 2.43 2.83 0.60 1.01

< 3.0

< 2.5

< 2.2

< 3.8

< 4.0

< 5.4

< 3.7

< 11.9

< 2.7

< 2.2

< 1.7

< 4.3

< 3.1

< 1.7

< 1.6

< 4.4

< 2.6

< 4.0

< 1.7

< 4.7

< 2.0

< 3.0

< 2.1

< 5.1

< 3.2

< 2.5

< 2.3

< 6.1

< 1.8

< 2.8

< 2.1

< 4.7

< 1.9

< 4.0

< 3.8

< 3.7 01-04-16 04-04-16 07-05-16 10-03-16 KWW-99 KWW-1370 KWW-3361 KWW-5320 0.5 +/- 0.3

< 1.1 4.8 +/- 0.4 0.5 +/- 0.3

< 145

< 148

< 149

< 142 0.90 0.95 6.42

< 0.30

< 2.6

< 2.5

< 4.6

< 2.0

< 8.3

< 4.4

< 6.1

< 4.3

< 3.6

< 1.9

< 3.1

< 2.7

< 4.4

< 2.0

< 3.6

< 2.6

< 5.0

< 4.1

< 4.6

< 4.8

< 5.6

< 3.7

< 3.4

< 4.1

< 5.2

< 2.2

< 4.0

< 3.0

< 5.3

< 2.8

< 3.4

< 3.1

< 4.8

< 3.7

< 4.4

< 3.o 42

KPS Table 17.

Well water, analyses for gross beta, tritium, potassium-40, and gamma-emitting isotopes.

Collection:

Quarterly.

Sample Description and Concentration (pCi/L)

Indicator K-38 Date Collected 01-04-16 04-04-16 07-05-16 10-03-16 Lab Code KWW-101 KWW-1372 KWW-3363 KWW-5322 Gross beta

< 0.5 29.9 +/- 2.1 0.8 +/- 0.4 1.4 +/- 0.4 H-3

< 145

< 148

< 149

< 142 K-40 (ICP)

< 0.30 31.32 1.08 1.76 Mn-54

< 2.7

< 1.7

< 1.0

< 3.2 Fe-59

< 4.2

< 5.1

< 3.8

< 3.3 Co-58

< 2.6

< 3.0

< 1.8

< 3.5 Co-60

< 2.5

< 1.9

< 1.5

< 1.8 Zn-65

< 3.3

< 4.5

< 2.6

< 3.5 Zr-Nb-95

< 3.0

< 3.3

< 1.9

< 3.1 Cs-134

< 2.6

< 2.4

< 2.1

< 3.4 Cs-137

< 3.8

< 2.4

< 2.0

< 3.2 Ba-La-140

< 3.0

< 2.1

< 3.3

< 2.9 Control K-13 Date Collected 01-04-16 04-04-16 07-05-16 10-03-16 Lab Code KWW-100 KWW-1371 KWW-3362 KWW-5321 Gross beta 0.7 +/- 0.3

< 1.1 0.7 +/- 0.3 0.5 +/- 0.3 H-3

< 145

< 148

< 149

< 142 K-40 (ICP) 0.97 0.97 0.96 1.02 Mn-54

< 2.9

< 5.1

< 1.8

< 2.2 fe-59

< 4.2

< 10.5

< 2.2

< 2.7 Co-58

< 2.8

< 4.2

< 1.5

< 2.6 Co-60

< 1.9

< 4.0

< 1.5

< 3.3 Zn-65

< 4.9

< 7.9

< 2.3

< 2.6 Zr-Nb-95

< 2.9

< 4.9

< 1.7

< 3.3 Cs-134

< 2.8

< 5.1

< 2.0

< 4.5 Cs-137

< 3.4

< 3.3

< 2.3

< 4.0 Ba-La-140

< 2.5

< 7.5

< 3.6

< 5.4 a Result of reanalysis 22.9 +/- 0.9 43

Table 18.

Location Date Collected Lab Code Gross Alpha Gross Beta Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Domestic meat samples (chickens), analyses of flesh for gross alpha, gross beta, and gamma-emitting isotopes. Annual collection.

Sample Description and Concentration (pCi/g wet)

Indicator Control K-24 K-32 09-06-16 09-06-16 KME-4758 KME-4759

< 0.023

< 0.036 2.79 +/- 0.044 2.54 +/- 0.073

< 0.32

< 0.26 2.53 +/- 0.48 2.29 +/- 0.35

< 0.044

< 0.029

< 0.055

< 0.027

< 0.037

< 0.030

< 0.179

< 0.137

< 0.022

< 0.020

< 0.014

< 0.022

< 0.045

< 0.067

< 0.163

< 0.108 44

KPS Table 19. Eggs, analyses for gross beta, strontium-89, strontium-90 and gamma emitting isotopes.

Collection: Quarterly Sample Description and Concentration (pCi/g wet)

Location K-24 Date Collected 01-04-16 04-04-16 07-05-16 10-03-16 Lab Code KE-102 KE-1364 KE-3345 KE-5175 Gross beta 1.62 +/- 0.05 1.42 +/- 0.04 1.55 +/- 0.06 1.72 +/- 0.07 Sr-89

< 0.004

< 0.005

< 0.003

< 0.008 Sr-90

< 0.002

< 0.002

< 0.001

< 0.003 Be-7

< 0.034

< 0.050

< 0.074

< 0.047 K-40 1.18 +/- 0.12 1.69 +/- 0.16 1.25 +/- 0.14 1.33 +/- 0.15 Nb-95

< 0.006

< 0.008

< 0.011

< 0.011 Zr-95

< 0.006

< 0.012

< 0.009

< 0.015 Ru-103

< 0.005

< 0.007

< 0.010

< 0.013 Ru-106

< 0.043

< 0.030

< 0.053

< 0.058 Cs-134

< 0.004

< 0.006

< 0.005

< 0.006 Cs-137

< 0.003

< 0.006

< 0.004

< 0.005 Ce-141

< 0.016

< 0.015

< 0.024

< 0.029 Ce-144

< 0.031

< 0.050

< 0.032

< 0.048 Location K-32 Date Collected 01-04-16 04-04-16 07-05-16 10-03-16 Lab Code KE-103 KE-1365 KE-3346 KE-5176 Gross beta 1.44 +/- 0.04 1.38 +/- 0.04 1.21 +/- 0.05 1.48 +/- 0.06 Sr-89

< 0.004

< 0.004

< 0.005

< 0.007 Sr-90

< 0.002

< 0.002

< 0.002

< 0.002 Be-7

< 0.065

< 0.053

< 0.065

< 0.062 K-40 1.26 +/- 0.14 1.23 +/- 0.13 1.35 +/- 0.16 1.57 +/- 0.17 Nb-95

< 0.007

< 0.004

< 0.012

< 0.010 Zr-95

< 0.011

< 0.010

< 0.014

< 0.017 Ru-103

< 0.006

< 0.006

< 0.006

< 0.015 Ru-106

< 0.049

< 0.037

< 0.040

< 0.053 Cs-134

< 0.005

< 0.006

< 0.007

< 0.005 Cs-137

< 0.003

< 0.006

< 0.005

< 0.004 Ce-141

< 0.011

< 0.011

< 0.022

< 0.039 Ce-144

< 0.027

< 0.048

< 0.043

< 0.063 45

Table 20.

Location Date Collected Lab Code Type Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Vegetable and grain samples, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes. Annual collection.

Sample Description and Concentration (pCi/g wet)

Indicator K-23 K-1a K-43 08-01-16 08-01-16 09-06-16 10-03-16 KVE-4044 KVE-4045 KVE-4742 KVE-5306 Clover Wheat Corn Pumpkin 5.12 +/- 0.11 9.50 +/- 0.23 3.19 +/- 0.07 2.75 +/- 0.07

< 0.011

< 0.031

< 0.009

< 0.007

< 0.004 0.031 +/- 0.010

< 0.005

< 0.002 0.58 +/- 0.15 0.94 +/- 0.155

< 0.082

< 0.039 3.85 +/- 0.35 5.99 +/- 0.37 2.24 +/- 0.20 1.97 +/- 0.13.

< 0.011

< 0.011

< 0.009

< 0.006

< 0.021

< 0.017

< 0.008

< 0.004

< 0.013

< 0.007

< 0.005

< 0.005

< 0.081

< 0.092

< 0.038

< 0.018

< 0.011

< 0.011

< 0.006

< 0.004

< 0.015

< 0.011

< 0.007

< 0.005

< 0.019

< 0.014

< 0.016

< 0.008

< 0.065

< 0.050

< 0.052

< 0.021 46

Table 20.

Location Date Collected Lab Code Type Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Date Collected Lab Code Type Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Vegetable and grain samples, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/g wet)

K-26 (control) 09-06-16 09-06-16 09-06-16 KVE-4743 KVE-4744 KVE-4745 Carrots Zucchini Kohlrabi 4.37 +/- 0.08 2.35 +/-" 0.04 3.25 +/- 0.06

< 0.006

< 0.005

< 0.004

< 0.003

< 0.002

< 0.002

< 0.068

< 0.037

< 0.053 4.15 +/- 0.25 1.96 +/- 0.14 2.85 +/- 0.16

< 0.005

< 0.008

< 0.005

< 0.008

< 0.005

< 0.006

< 0.005

< 0.006

< 0.004

< 0.057

< 0.041

< 0.032

< 0.006

< 0.005

< 0.005

< 0.003

< 0.004

< 0.005

< 0.013

< 0.016

< 0.014

< 0.043

< 0.043

< 0.051 K-26 (control)

K-26 (control) 09-07-16 10-04-16 KVE-4747 KVE-5305 Corn Pumpkin 2.11 +/- 0.04 1.88 +/- 0.05

< 0.005

< 0.002

< 0.002

< 0.001

< 0.073

< 0.035 1.90 +/- 0.18 1.55 +/- 0.11

< 0.012

< 0.006

< 0.008

< 0.006

< 0.006

< 0.003

< 0.069

< 0.020

< 0.006

< 0.003

< 0.005

< 0.003

< 0.011

< 0.011

< 0.031

< 0.033 47 09-06-16 KVE-4746 Watermelon 2.21 +/- 0.04

< 0.003

< 0.002

< 0.036 1.74 +/- 0.13

< 0.006

< 0.009

< 0.004

< 0.034

< 0.004

< 0.004

< 0.010

< 0.028

KPS Table 21.

Cattlefeed, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection:

First Quarter.

Sample Description and Concentration (pCi/g wet)

Control Location K-3 K-35 K-3 K-35 Date Collected 01-04-16 01-04-16 01-04-16 01-04-16 Lab Code KCF-25 KCF-28 KCF-31 KCF-34 Type Hay Hay Silage Silage Gross beta 19.34 +/- 0.42 14.75 +/- 0.36 4.92 +/- 0.11 11.90 +/- 0.24 Sr-89

< 0.034

< 0.044

< 0.010

< 0.032 Sr-90

< 0.015 0.022 +/- 0.012 0.005 +/- 0.003 0.023 +/- 0.009 Be-7

< 0.232 0.58 +/- 0.27 0.31 +/- 0.10

< 0.10 K-40 18.13 +/- 0.96 11.04 +/- 0.92 3.50 +/- 0.23 9.47 +/- 0.41 Nb-95

< 0.025

< 0.029

< 0.012

< 0.014 Zr-95

< 0.048

< 0.038

< 0.012

< 0.011 Ru-103

< 0.019

< 0.029

< 0.008

< 0.010 Ru-106

< 0.170

< 0.215

< 0.039

< 0.068 Cs-134

< 0.022

< 0.030

< 0.007

< 0.008 Cs-137

< 0.030

< 0.028

< 0.008

< 0.008 Ce-141

< 0.034

< 0.046

< 0.020

< 0.015 Ce-144

< 0.112

< 0.225

< 0.050

< 0.039 Indicator Location K-5 K-34 K-38 K-39 Date Collected 01-04-16 01-04-16 01-04-16 01-04-16 Lab Code KCF-26 KCF-27 KCF-29 KCF-30 Type Hay Hay Hay Hay Gross beta 19.41 +/- 0.44 22.56 +/- 0.47 14.23 +/- 0.31 18.05 +/- 0.45 Sr-89

< 0.034

< 0.028

< 0.021

< 0.039 Sr-90

< 0.013 0.015 +/- 0.007 0.026 +/- 0.007

< 0.016 Be-7 1.37 +/- 0.19

< 0.23 0.32 +/- 0.16 0.40 +/- 0.23 K-40 15.28 +/- 0.71 17.69 +/- 0.87 13.24 +/- 0.67 15.10 +/- 0.82 Nb-95

< 0.011

< 0.022

< 0.019

< 0.017 Zr-95

< 0.027

< 0.052

< 0.035

< 0.027 Ru-103

< 0.017

< 0.017

< 0.020

< 0.024 Ru-106

< 0.096

< 0.189

< 0.110

< 0.199 Cs-134

< 0.018

< 0.026

< 0.018

< 0.022 Cs-137

< 0.014

< 0.029

< 0.009

< 0.022 Ce-141

< 0.020

< 0.051

< 0.037

< 0.044 Ce-144

< 0.116

< 0.136

< 0.100

< 0.116 48

Table 21.

Location Date Collected Lab Code Type Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Cattlefeed, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/g wet)

Indicator K-5 K-34 K-38 K-39 01-04-16 01-04-16 01-04-16 01-04-16 KCF-32 KCF-33 KCF-35 KCF-36 Silage Silage Silage Silage 3.89 +/- 0.08 3.89 +/- 0.08 5.86 +/- 0.15 10.15 +/- 0.24

< 0.009

< 0.013

< 0.022

< 0.021 0.012 +/- 0.003 0.006 +/- 0.003

< 0.009 0.009 +/- 0.005

< 0.04

< 0.06 0.13 +/- 0.09 0.30 +/- 0.09 2.99 +/- 0.20 3.10 +/- 0.22 4.61 +/- 0.21 7.86 +/- 0.36

< 0.007

< 0.007

< 0.008

< 0.009

< 0.007

< 0.013

< 0.015

< 0.017

< 0.004

< 0.006

< 0.007

< 0.012

< 0.044

< 0.066

< 0.044

< 0.073

< 0.005

< 0.007

< 0.007

< 0.008

< 0.007

< 0.007

< 0.008

< 0.008

< 0.008

< 0.018

< 0.011

< 0.019

< 0.040

< 0.048

< 0.034

< 0.064 49

KPS Table 22.

Grass, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection: Quarterly, April through December Units: pCi/g wet Sample Description and Concentration Indicator Location K-1b K-1f K-5 Date Collected 06-01-16 06-01-16 06-01-16 Lab Code KG-2728 KG-2729 KG-2731 Gross beta 7.77 +/- 0.15 6.41 +/- 0.12 8.24 +/- 0.15 Sr-89

< 0.010

< 0.006

< 0.012 Sr-90

< 0.007

< 0.004

< 0.008 Be-7 0.79 +/- 0.22 0.38 +/- 0.19 0.61 +/-0.17 K-40 6.44 +/- 0.53 4.98 +/- 0.43 7.18+/-0.47 Mn-54

< 0.021

< 0.014

< 0.011 Co-58

< 0.016

< 0.014

< 0.009 Co-60

< 0.012

< 0.009

< 0.011 Nb-95

< 0.017

< 0.009

< 0.014 Zr-95

< 0.022

< 0.027

< 0.027 Ru-103

<0.015

< 0.015

< 0.014 Ru-106

<0.161

< 0.128

< 0.124 Cs-134

< 0.019

< 0.017

<0.015 Cs-137

< 0.019

< 0.019

< 0.016 Ce-141

< 0.033

< 0.031

< 0.025 Ce-144

< 0.095

< 0.122

< 0.106 Indicator Location K-38 K-39 K-3 Date Collected 06-01-16 06-01-16 06-01-16 Lab Code KG-2735 KG-2736 KG-2730 Gross beta 8.01 +/- 0.15 5.48 +/- 0.10 12.09 +/- 0.21 Sr-89

< 0.008

< 0.004

< 0.006 Sr-90

< 0.004

< 0.002

< 0.004 Be-7 0.36 +/- 0.11 0.39 +/- 0.13 0.26 +/- 0.11 K-40 5.98 +/- 0.34 4.67 +/- 0.32 6.23 +/- 0.42 Mn-54

< 0.007

<0.010

< 0.008 Co-58

< 0.011

< 0.005

< 0.009 Co-60

< 0.003

< 0.009

< 0.008 Nb-95

< 0.009

< 0.011

< 0.009 Zr-95

< 0.014

<0.010

< 0.018 Ru-103

< 0.007

< 0.011

< 0.013 Ru-106

< 0.105

< 0.087

< 0.115 Cs-134

< 0.008

< 0.010

< 0.011 Cs-137

< 0.008

< 0.010

< 0.014 Ce-141

< 0.017

< 0.023

< 0.021 Ce-144

< 0.059

< 0.058

< 0.063 50 K-34 06-01-16 KG-2733 6.47 +/- 0.11

< 0.006

< 0.004 0.58 +/- 0.24 5.13 +/- 0.59

< 0.020

< 0.017

< 0.013

< 0.015

< 0.036

< 0.018

< 0.133

< 0.020

< 0.020

< 0.036

< 0.157 Control K-35 06-01-16 KG-2734 6.40 +/- 0.12

< 0.007

< 0.004 0.50 +/- 0.18 5.54 +/- 0.41

< 0.011

< 0.011

< 0.009

< 0.012

< 0.021

< 0.015

< 0.138

< 0.013

. < 0.010

< 0.032

< 0.088

KPS Table 22.

Grass samples, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes (continued).

Sample Description and Concentration Indicator Location K-1b K-1f K-5 K-34 Date Collected 08-01-16 08-01-16 08-01-16 08-01-16 Lab Code KG-4098 KG-4099 KG-4101 KG-4102 Gross beta 8.05 +/- 0.19

.7.40 +/- 0.17 8.90 +/- 0.18 8.88 +/- 0.18 Sr-89

< 0.025

< 0.017

< 0.014

< 0.023 Sr-90

< 0.014

< 0.009

< 0.008

< 0.014 Be-7 3.02 +/- 0.32 1.48 +/- 0.26 0.96 +/- 0.19 1.11 +/- 0.29 K-40 6.67 +/- 0.51 7.43 +/- 0.55 8.72 +/- 0.49 8.31 +/- 0.70 Mn-54

< 0.014

< 0.012

< 0.013

< 0.023 Co-58

< 0.017

< 0.010

< 0.017

< 0.023 Co-60

< 0.014

< 0.015

< 0.016

< 0.014 Nb-95

< 0.021

< 0.022

< 0.009

< 0.026 Zr-95

< 0.024

< 0.036

< 0.028

< 0.037 Ru-103

< 0.020

< 0.015

< 0.013

< 0.027 Ru-106

<0.101

< 0.111

<0.144

< 0.260 Cs-134

< 0.018

<0.018

< 0.016

< 0.026 Cs-137

< 0.014

< 0.017

< 0.016

<0.019 Ce-141

< 0.031

< 0.026

< 0.037

< 0.044 Ce-144

< 0.119

< 0.120

<0.117

< 0.142 Indicator Control Location K-38 K-39 K-3 K-35 Date Collected 08-01-16 08-01-16 08-01-16 08-01-16 Lab Code KG-4104 KG-4105 KG-4100 KG-4103 Gross beta 9.94 +/- 0.20 7.10 +/- 0.18 9.38 +/- 0.19 8.55 +/- 0.19 Sr-89

< 0.021

< 0.022

< 0.026

< 0.015 Sr-90

<0.012

< 0.012

< 0.015

< 0.008 Be-7 2.09 +/- 0.34 2.58 +/- 0.23 1.40 +/- 0.21 1.70 +/- 0.31 K-40 8.03 +/- 0.73 4.71 +/- 0.37 7.26 +/- 0.50 9.11 +/- 0.75 Mn-54

< 0.022

< 0.012

< 0.012

< 0.021 Co-58

< 0.022

< 0.011

< 0.007

< 0.019 Co-60

< 0.009

< 0.013

< 0.010

< 0.016 Nb-95

< 0.019

< 0.017

< 0.010

< 0.023 Zr-95

< 0.032

< 0.019

< 0.016

< 0.035 Ru-103

< 0.025

< 0.014

< 0.011

< 0.019 Ru-106

< 0.158

< 0.099

< 0.131

< 0.115 Cs-134

< 0.024

< 0.014

< 0.015

< 0.022 Cs-137

< 0.026

<0.013

< 0.009

< 0.027 Ce-141

< 0.040

< 0.028

< 0.031

< 0.042 Ce-144

< 0.173

< 0.103

< 0.125

< 0.099 51

KPS Table 22.

Grass samples, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/g wet)

Indicator Location K-1b K-1f K-5 K-34 Date Collected 10-03-16 10-03-16 10-03-16 10-03-16 Lab Code KG-5297 KG-5298 KG-5300 KG-5301 Gross beta 7.60 +/- 0.27 6.74 +/- 0.30 8.51 +/- 0.26 9.29 +/- 0.28 Sr-89

< 0.021

< 0.040

< 0.016

< 0.019 Sr-90

< 0.013

< 0.026

< 0.009

< 0.012 Be-7 5.33 +/- 0.34 4.59 +/- 0.37 3.72 +/- 0.30 5.32 +/- 0.18 K-40 5.01 +/- 0.38 5.83 +/- 0.50 6.35 +/- 0.45 8.24 +/- 0.26 Mn-54

< 0.012

< 0.017

< 0.017

< 0.010 Co-58

< 0.010

< 0.021

< 0.009

< 0.009 Co-60

< 0.010

< 0.014

< 0.009

< 0.005 Nb-95

< 0.015

< 0.021

< 0.013

< 0.011 Zr-95

< 0.017

< 0.032

< 0.033

< 0.016 Ru-103

< 0.018

< 0.019

< 0.019

< 0.008 Ru-106

< 0.098

< 0.195

< 0.085

< 0.084 Cs-134

< 0.013

< 0.019

< 0.015

< 0.008 Cs-137

< 0.015

< 0.022

< 0.019

< 0.009 Ce-141

< 0.030

< 0.045

< 0.030

< 0.018 Ce-144

< 0.078

< 0.109

< 0.101

< 0.070 Indicator Control Location K-38 K-39 K-3 K-35 Date Collected 10-03-16 10-03-16 10-03-16 10-03-16 Lab Code KG-5303 KG-5304 KG-5299 KG-5302 Gross beta 9.06 +/- 0.34 7.12 +/- 0.24 8.54 +/- 0.27 7.72 +/- 0.20 Sr-89

< 0.019

< 0.016

< 0.021

< 0.013 Sr-90

< 0.012

< 0.010

< 0.013

< 0.008 Be-7 6.31 +/- 0.32 2.87 +/- 0.26 3.81 +/- 0.31 2.12 +/- 0.25 K-40 7.75 +/- 0.44 7.15 +/- 0.51 8.53 +/- 0.54 6.26 +/- 0.43 Mn-54

< 0.010

< 0.015

< 0.017

< 0.013 Co-58

< 0.014

< 0.014

< 0.015

< 0.012 Co-60

< 0.011

< 0.013

< 0.011

< 0.015 Nb-95

< 0.018

< 0.013

< 0.016

< 0.008 Zr-95

< 0.022

< 0.027

< 0.026

< 0.016 Ru-103

< 0.011

< 0.018

< 0.013

< 0.020 Ru-106

< 0.107

< 0.130

< 0.112

< 0.113 Cs-134

< 0.012

< 0.015

< 0.015

< 0.013 Cs-137

< 0.015

< 0.017

<: 0.018

< 0.011 Ce-141

< 0.017

< 0.034

< 0.029

< 0.031 Ce-144

< 0.071

< 0.106

< 0.093

< 0.113 52

Table 23.

Location Date Collected Lab Code Gross alpha Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Date Collected Lab Code Gross alpha Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Soil samples, analyses for gross alpha, gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection: Semiannually Sample Description and Concentration (pCi/g dry)

Indicator K-1f K-5 05-02-16 05-02-16 KSO-2148 KSO-2150 9.79 +/- 3.30 8.69 +/- 3.29 26.93 +/- 2.95 30.13 +/- 3.17

< 0.111

< 0.066

< 0.039

< 0.022

< 0.35

< 0.30 21.86 +/- 1.02 20.92 +/- 0.79

< 0.066

< 0.072

< 0.093

< 0.051

< 0.063

< 0.034

< 0.216

< 0.134

< 0.025

< 0.017 0.10 +/- 0.04 0.06 +/- 0.02

< 0.147

< 0.096

< 0.124

< 0.157 10-03-16 10-03-16 KSO-5349 KSO-5352 9.25 +/- 1.62 7.96 +/- 1.49 26.75 +/- 1.53 24.77 +/- 1.26

< 0.070

< 0.073

< 0.028

< 0.029

< 0.22

< 0.37 18.94 +/- 0.80 17.75 +/- 0.87

< 0.048

< 0.051

< 0.057

< 0.046

< 0.038

< 0.049

< 0.186

< 0.207

< 0.014

< 0.024 0.13 +/- 0.02 0.07 +/- 0.03

< 0.093

< 0.082

< 0.173

< 0.112 53

Table 23.

Location Date Collected Lab Code Gross alpha Gross beta Sr~89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Date Collected Lab Code Gross alpha Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Soil samples, analyses for gross alpha, gross beta, strontium-89, strontium-90, and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/g dry)

Indicator K-34 K-38 K-39 05-02-16 05-02-16 05-02-16 KSO-2151 KSO-2153 KSO-2155 7.75 +/- 3.67 8.63 +/- 2.37 7.77 +/- 3.34 26.65 +/- 2.96 30.29 +/- 2.22 30.07 +/- 3.32

< 0.054

< 0.095

< 0.092

< 0.018

< 0.033

< 0.032

< 0.28

< 0.26

< 0.26 19.41 +/- 0.73 21.80 +/- 0.81 21.29 +/- 0.86

< 0.058

< 0.076

< 0.070

< 0.038

< 0.035

< 0.072

< 0.034

< 0.040

< 0.045

< 0.153

< 0.192

< 0.162

< 0.013

< 0.014

< 0.016 0.10 +/- 0.02 0.11 +/- 0.03 0.10 +/- 0.03

< 0.092

< 0.088

< 0.108

< 0.142

< 0.154

< 0.133 10-03-16 10-03-16 10-03-16 KSO-5353 KSO-5355 KSO-5356 7.89 +/- 1.89 9.23 +/- 1.63 7.53 +/- 1.94 27.63 +/- 1.69 32.63 +/- 1.50 28.37 +/- 1.83

< 0.096

< 0.083

< 0.067

< 0.036

< 0.033

< 0.028

< 0.34

< 0.50

< 0.41 19.09 +/- 0.79 23.22 +/- 1.21 21.42 +/- 1.07

< 0.073

< 0.047

< 0.051

< 0.057

< 0.088

< 0.053

< 0.048

< 0.056

< 0.063

< 0.243

< 0.301

< 0.279

< 0.024

< 0.029

< 0.031 0.11 +/- 0.03 0.11 +/- 0.06 0.12 +/- 0.05

< 0.106

< 0.115

< 0.119

< 0.140

< 0.134

< 0.179 54

Table 23.

Location Date Collected Lab Code Gross alpha Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Date Collected Lab Code Gross alpha Gross beta Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 KPS Soil samples, analyses for gross alpha, gross beta, strontium-89, strontium-90, and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/g dry)

Control K-3 K-35 05-02-16 05-02-16 KSO-2149 KSO-2152 4.12 +/- 2.39 7.98 +/- 3.12 24.79 +/- 2.99 22.87 +/- 2.74

< 0.076

< 0.060

< 0.025

< 0.022

< 0.41

< 0.31 19.50 +/- 1.14 16.22 +/- 0.68

< 0.080

< 0.031

< 0.061

< 0.031

< 0.055

< 0.041

< 0.292

< 0.164

< 0.024

< 0.015 0.13 +/- 0.04 0.08 +/- 0.02

< 0.148

< 0.100

< 0.224

< 0.131 10-03-16 10-03-16 KSO-5350 KSO-5354 7.80 +/- 1.75 7.95 +/- 2.21 28.33 +/- 1.69 22.66 +/- 1.59

< 0.090

< 0.079

< 0.036

< 0.032

< 0.32

< 0.44 19.45 +/- 1.13 17.15 +/- 0.97

< 0.078

< 0.070

< 0.090

< 0.072

< 0.068

< 0.040

< 0.213

< 0.163

< 0.034

< 0.026 0.11 +/- 0.05 0.07 +/- 0.03

< 0.125

< 0.118

< 0.117

< 0.197 55

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40 and gamma-emitting isotopes.

Collection:

Monthly Sample Description and Concentration (pCi/L)

Indicator K-1a Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1b Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 01-04-16 KSW-87

< 0.7 4.6 +/- 1.0 4.6 +/- 1.0 4.38

< 2.7

< 6.7

< 2.4

< 4.0

< 4.5

< 4.6

< 3.5

< 4.3

< 3.9 01-04-16 KSW-88

< 0.8 2.0 +/- 0.6 2.0 +/- 0.6 2.17

< 2.3

< 2.9

< 2.5

< 2.1

< 1.9

< 4.5

< 3.0

< 3.2

< 2.2 02-01-16 KSW-441

< 0.7 3.9 +/- 0.7 3.9 +/- 0.7 4.44

< 2.5

< 7.2

< 2.7

< 2.4

< 4.1

< 2.4

< 4.4

< 3.1

< 4.2 02-01-16 KSW-442

< 0.7 2.5 +/- 0.5 2.5 +/- 0.5 1.85

< 2.3

< 6.6

< 1.6

< 2.6

< 4.9

< 2.8

< 3.0

< 2.4

< 5.2 56 03-01-16 KSW-853 0.9 +/- 0.4 7.4 +/- 0.9 8.3 +/- 1.0 4.12

< 2.6

< 6.2

< 3.7

< 1.9

< 4.2

< 2.8

< 3.5

< 2.0

< 2.1 03-01-16 KSW-854

< 0.7 4.1 +/- 0.7 4.1 +/- 0.7 2.52

< 2.3

< 4.7

< 2.3

< 2.4

< 4.7

< 3.3

< 3.1

< 3.1

< 2.7

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1a Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1b Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 04-04-16 05-02-16 06-01-16 KSW-1355 KSW-2134 KSW-2826

< 0.7

< 0.7

< 0.7 6.1+/-1.1 5.3 +/- 1.5 6.6 +/- 1.5 6.1 +/- 1.1 5.3 +/- 1.5 6.6 +/- 1.5 3.69 3.93 4.59

< 1.9

< 1.5

< 4.3

< 6.2

< 6.6

< 7.5

< 1.7

< 3.3

< 3.9

< 2.3

< 1.8

< 2.9

< 2.0

< 2.1

< 14.8

< 3.5

< 4.6

< 5.3

< 2.9

< 3.2

< 5.5

< 2.0

< 2.6

< 3.0

< 5.6

< 7.3

< 3.6 04-04-16 05-02-16 06-01-16 KSW-1356 KSW-2135 KSW-2827

< 0.7

< 0.7

< 0.7 4.1 +/- 0.9 3.9 +/- 1.1 4.2 +/- 1.2 4.1 +/- 0.9 3.9 +/- 1.1 4.2 +/- 1.2 1.93 2.04 2.02

< 1.7

< 1.7

< 2.7

< 4.1

< 3.1

< 3.9

< 2.7

< 2.3

< 1.4

< 1.1

< 2.0

< 2.5

< 2.6

< 2.4

< 4.3

< 3.4

< 4.4

< 2.9

< 2.8

< 2.8

< 3.7

< 3.6

< 3.1

< 3.6

< 2.6

< 5.9

< 3.6 57

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1a Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1b Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 07-05-16 08-01-16 KSW-3349 KSW-4076

< 0.7

< 0.7 7.6 +/- 0.9 19.0 +/- 1.7 7.6 +/- 0.9 19.0 +/- 1.7 6.00 20.50

< 2.4

< 2.2

< 5.1

< 4.6

< 2.6

< 2.1

< 1.1

< 0.9

< 2.4

< 3.9

< 2.8

< 4.0

< 2.6

< 3.1

< 2.0

< 3.3

< 4.5

< 7.5 07-05-16 08-01-16 KSW-3350 KSW-4077 1.5 +/- 0.5

< 0.7 3.1 +/- 0.7 4.5 +/- 0.9 4.6 +/- 0.9 4.5 +/- 0.9 2.04 2.17

< 2.4

< 2.4

< 3.7

< 2.5

< 2.2

< 2.4

< 2.2

< 1.1

< 4.2

< 4.7

< 3.3

< 3.1

< 2.3

< 2.8

< 2.9

< 1.8

< 2.9

< 5.2 58 09-06-16 KSW-4733

< 1.5 62.6 +/- 3.6 62.6 +/- 3.6 64.12

< 4.8

< 4.7

< 2.0

< 3.8

< 6.3

< 3.0

< 4.6

< 5.8

< 4.1 09-06-16 KSW-4734

< 0.7 2.2 +/- 0.6 2.2 +/- 0.6 1.71

< 2.7

< 4.9

< 3.9

< 2.0

< 1.7

< 2.6

< 4.0

< 3.0

< 2.1

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1a Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1b Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 10-03-16 11-01-16 KSW-5308 KSW-5974

< 0.5

< 1.0 11.2 +/- 1.5 14.9 +/- 1.9 11.2 +/- 1.5 14.9 +/- 1.9 6.55 14.76

< 2.0

< 4.0

< 1.8

< 5.0

< 1.8

< 3.8

< 1.6

< 3.7

< 2.5

< 4.5

< 3.2

< 3.8

< 3.1

< 4.1

< 2.6

< 3.3

< 4.3

< 4.9 10-03-16 11-01-16 KSW-5309 KSW-5975

< 0.5 0.7 +/- 0.5 5.0 +/- 0.9 3.8 +/- 0.9 5.0 +/- 0.9 4.5 +/- 1.0 3.47 3.44

< 5.0

< 4.4

< 10.6

< 6.2

< 3.9

< 2.2

< 3.9

< 3.2

< 9.6

< 5.5

< 4.2

< 4.5

< 6.4

< 4.4

< 5.3

< 2.7

< 3.8

< 2.0 59 12-01-16 KSW-6642

< 0.7 10.5 +/- 0.9 10.5 +/- 0.9 7.81

< 3.5

< 5.0

< 4.3

< 4.1

< 7.7

< 4.1

< 4.4

< 3.8

< 4.0 12-01-16 KSW-6643

< 0.7 5.5 +/- 0.6 5.5 +/- 0.6 4.71

< 3.6

< 7.0

< 3.1

< 3.0

< 4.1

< 5.0

< 3.9

< 4.6

< 3.9

KPS Table 24. Surface water samples, analyses for gross beta, potassium~40 and gamma-emitting isotopes (continued).

Indicator K-1d Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1e Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 01-04-16 02-01-16 KSW-89 KSW-443

< 0.7

< 0.7 1.5 +/- 0.4 1.4 +/- 0.3 1.5 +/- 0.4 1.4 +/- 0.3 1.49 1.21

< 3.6

< 2.9

< 12.0

< 5.2

< 5.2

< 1.1

< 3.8

< 3.3

< 7.5

< 3.1

< 2.8

< 3.1

< 6.0

< 3.1

< 4.6

< 1.9

< 7.4

< 2.6 01-04-16 02-01-16 KSW-90 KSW-444

< 0.7

< 0.8 1.6 +/- 0.8 2.9 +/- 0.7 1.6 +/- 0.8 2.9 +/- 0.7 1.66 2.16

< 3.0

< 6.0

< 3.9

< 8.6

< 2.9

< 5.7

< 2.4

< 3.7

< 2.2

< 10.0

< 3.3

< 5.6

< 3.3

< 5.3

< 1.9

< 5.0

< 2.7

< 5.8 60 03-01-16 KSW-855

< 0.8 1.8 +/- 0.3 1.8 +/- 0.3 1.60

< 2.8

< 4.1

< 2.9

< 1.0

< 3.3

< 3.6

< 2.7

< 3.2

< 2.4 03-01-16 KSW-856

< 0.7 2.1 +/- 0.8 2.1 +/- 0.8 1.80

< 3.3

< 5.7

< 1.2

< 1.9

< 2.8

< 2.0

< 3.0

< 2.8

< 1.6

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1d Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1e Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co~60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 04-04-16 05-02-16 KSW-1357 KSW-2136

< 0.7

< 0.7 2.5 +/- 0.5 2.6 +/- 0.8 2.5 +/- 0.5 2.6 +/- 0.8 1.35 1.34

< 3.1

< 2.0

< 4.4

< 6.6

< 2.8

< 2.8

< 2.1

< 2.6

< 3.1

< 3.7

< 3.5

< 5.6

< 2.6

< 3.7

< 2.0

< 2.5

< 3.2

< 3.8 04-04-16 05-02-16 KSW-1358 KSW-2137

< 0.7

< 0.8 3.3 +/- 1.1 2.4 +/- 1.3 3.3 +/- 1.1 2.4 +/- 1.3 1.47 1.65

< 2.4

< 2.4

< 6.5

< 8.8

< 1.7

< 2.7

< 1.6

< 1.9

< 3.1

< 3.7

< 2.4

< 2.9

< 3.0

< 2.9

< 2.1

< 3.0

< 3.2

< 7.4 61 06-01-16 KSW-2828

< 0.7 1.6 +/- 0.6 1.6 +/- 0.6 1.16

< 2.2

< 6.1

< 2.6

< 2.1

< 5.2

< 3.2

< 3.0

< 2.5

< 3.0 06-01-16 KSW-2829

< 0.7 2.7+/-1.3 2.7+/-1.3 1.56

< 4.0

< 13.1

< 3.8

< 4.2

< 6.0

< 4.2

< 6.2

< 7.5

< 10.0

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1d Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1e Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 07-05-16 08-01-16 KSW-3351 KSW-4078

< 0.7

< 0.7 1.1 +/- 0.4 1.8 +/- 0.5 1.1 +/- 0.4 1.8 +/- 0.5 1.12 1.17

< 1.8

< 1.6

< 6.9

< 4.0

< 3.1

< 2.6

< 3.2

< 1.4

< 7.0

< 5.5

< 2.8

< 2.4

< 3.0

< 2.6

< 3.2

< 3.7

< 3.2

< 6.7 07-05-16 08-01-16 KSW-3352 KSW-4079

< 0.7

< 0.7 2.9 +/- 0.9 6.5 +/- 1.3 2.9 +/- 0.9 6.5 +/- 1.3 2.50 4.09

< 2.0

< 2.1

< 3.7

< 4.0

< 1.9

< 1.8

< 1.2

< 2.2

< 4.5

< 5.8

< 2.8

< 4.0

< 3.0

< 3.2

< 2.6

< 3.0

< 1.9

< 4.6 62 09-06-16 KSW-4735

< 0.7 1.2+/-0.4 1.2 +/- 0.4 1.08

< 3.1

< 7.1

< 3.2

< 2.8

< 5.8

< 3.5

< 4.7

< 5.0

< 2.8 09-06-16 KSW-4736

< 0.7 3.9 +/- 0.9 3.9 +/- 0.9 2.03

< 3.1

< 6.4

< 2.7

< 2.3

< 3.2

< 2.4

< 3.5

< 2.4

< 1.6

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1d Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-1e Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 10-03-16 11-01-16 KSW-5310 KSW-5976

< 0.5

< 0.7 1.8 +/- 0.5 1.5 +/- 0.4 1.8 +/- 0.5 1.5 +/- 0.4 1.19 1.16

< 2.6

< 2.8

< 4.0

< 6.1

< 2.6

< 3.5

< 2.6

< 3.7

< 4.6

< 3.7

< 2.7

< 3.3

< 3.2

< 4.7

< 2.9

< 2.5

< 3.0

< 2.6 10-03-16 11-01-16 KSW-5311 KSW-5977

< 0.5

< 0.7 3.8 +/- 1.2 3.2 +/- 0.9 3.8 +/- 1.2 3.2 +/- 0.9 3.43 2.66

< 2.7

< 5.2

< 3.1

< 7.5

< 3.4

< 3.7

< 3.7

< 4.0

< 7.4

< 7.4

< 2.9

< 4.9

< 3.9

< 6.6

< 5.4

< 5.2

< 3.3

< 4.0 63 12-01-16 KSW-6644

< 0.7 1.9 +/- 0.4 1.9+/-0.4 1.16

< 6.5

< 7.9

< 3.8

< 4.9

< 6.2

< 3.5

< 6.2

< 3.1

< 6.9 12-01-16 KSW-6645

< 0.7 4.7 +/- 0.8 4.7 +/- 0.8 2.71

< 3.6

< 4.5

< 3.1

< 3.0

< 2.9

< 3.6

< 4.0

< 3.8

< 2.2

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40 and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/L)

Indicator K-1k Date Collected 01-04-16 02-01-16 03-01-16 Lab Code KSW-91 KSW-445 KSW-857 Gross beta Suspended Solids

< 0.8

< 0.7

< 0.8 Dissolved Solids 7.5 +/- 0.8 9.5 +/- 0.8 7.8 +/- 0.6 Total Residue 7.5 +/- 0.8 9.5 +/- 0.8 7.8 +/- 0.6 K-40 (ICP) 7.12 8.36 7.17 Mn-54

< 3.0

< 2.1

< 2.7 Fe-59

< 6.5

< 6.5

< 4.4 Co-58

< 2.4

< 1.3

< 2.7 Co-60

< 2.1

< 2.5

< 1.4 Zn-65

< 2.7

< 1.9

< 6.3 Zr-Nb-95

< 3.2

< 4.0

< 2.6 Cs-134

< 3.3

< 2.3

< 3.6 Cs-137

< 3.5

< 2.1

< 3.9 Ba-La-140

< 3.5

< 4.7

< 2.5 Date Collected 04-04-16 05-02-16 06-01-16 Lab Code KSW-1359 KSW-2138 KSW-2830 Gross beta Suspended Solids

< 0.7

< 0.7

< 0.7 Dissolved Solids 6.2 +/- 0.7 8.3 +/- 1.1 8.8 +/- 1.0 Total Residue 6.2 +/- 0.7 8.3 +/- 1.1 8.8 +/- 1.0 K-40 (ICP) 4.13 7.58 5.77 Mn-54

< 2.2

< 1.8

< 2.6 Fe-59

< 5.8

< 4.0

< 6.4 Co-58

< 3.0

< 3.8

< 2.7 Co-60

< 1.7

< 2.1

< 2.2 Zn-65

< 5.3

< 3.3

< 2.5 Zr-Nb-95

< 4.3

< 4.9

< 2.2 Cs-134

< 3.0

< 3.6

< 3.2 Cs-137

< 2.6

< 3.4

< 2.4 Ba-La-140

< 2.8

< 10.0

< 1.8 64

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

Indicator K-1k Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 07-05-16 08-01-16 KSW-3353 KSW-4080

< 0.7

< 0.7 6.1 +/- 0.7 10.6 +/- 0.8 6.1 +/- 0.7 10.6 +/- 0.8 5.66 9.59

< 2.7

< 1.8

< 4.5

< 4.3

< 3.0

< 1.8

< 1.3

< 1.4

< 3.1

< 2.8

< 3.2

< 3.1

< 2.7

< 3.4

< 2.5

< 2.7

< 5.6

< 6.2 10-03-16 11-01-16 KSW-5312 KSW-5978

< 0.5

< 1.2 17.1 +/- 1.2 8.3 +/- 1.5 17.1+/-1.2 8.3 +/- 1.5 9.27 6.74

< 2.9

< 5.2

< 2.9

< 3.3

< 3.2

< 4.5

< 2.0

< 4.6

< 5.7

< 8.4

< 3.3

< 5.8

< 3.6

< 7.1

< 2.5

< 6.7

< 2.1

< 5.9 65 09-06-16 KSW-4737 1.4 +/- 0.4 9.1 +/-0.8 10.5 +/- 0.9 11.64

< 3.6

< 3.1

< 3.0

< 2.9

< 5.9

< 2.9

< 4.0

< 3.0

< 2.9 12-01-16 KSW-6646

< 0.3 11.8 +/- 1.0 11.8 +/- 1.0 7.10

< 6.8

< 3.8

< 2.7

< 3.6

< 5.1

< 2.9

< 5.1

< 3.7

< 3.9

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40 and gamma-emitting isotopes.

Collection:

Monthly K-9 (Raw)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-9 (Tap)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 01-04-16 02-01-16 KSW-92 KSW-446

< 0.7

< 0.7 1.6 +/- 0.4 1.9 +/- 0.3 1.6 +/- 0.4 1.9 +/- 0.3 1.17 1.21

< 2.2

< 3.7

< 3.5

< 8.8

< 4.8

< 5.2

< 2.8

< 3.4

< 4.7

< 4.4

< 4.1

< 5.4

< 4.4

< 5.6

< 2.8

< 5.2

< 8.4

< 5.3 01-04-16 02-01-16 KSW-93 KSW-447

< 0.8

< 0.7 1.0 +/- 0.4 1.7+/-0.4 1.0 +/- 0.4 1.7+/-0.4 1.18 1.17

< 2.7

< 1.9

< 4.3

< 5.1

< 2.7

< 2.8

< 2.7

< 2.2

< 4.7

< 4.7

< 3.0

< 3.0

< 3.5

< 2.3

< 2.4

< 3.0

< 2.7

< 5.0 66 03-01-16 KSW-858

< 0.7 2.3 +/- 0.4 2.3 +/- 0.4 1.16

< 1.8

< 4.4

< 2.3

< 2.2

< 1.7

< 3.2

< 2.8

< 2.7

< 3.2 03-01-16 KSW-859

< 0.8 1.7 +/- 0.5 1.7 +/- 0.5 1.31

< 3.3

< 6.3

< 2.1

< 1.0

< 6.6

< 3.3

< 3.4

< 3.1

< 1.5

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

K-9 (Raw)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-9 (Tap)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 04-04-16 05-02-16 KSW-1360 KSW-2139

< 0.7

< 0.8 2.3 +/- 0.5 1.5 +/- 0.7 2.3 +/- 0.5 1.5 +/- 0.7 1.12 1.21

< 2.6

< 2.3

< 6.5

< 7.1

< 3.0

< 1.9

< 1.2

< 2.5

< 4.8

< 5.1

< 3.6

< 4.5

< 2.9

< 3.3

< 2.4

< 2.9

< 4.2

< 5.4 04-04-16 05-02-16 KSW-1361 KSW-2140

< 0.8

< 0.7 2.1 +/- 0.6 2.2 +/- 0.7 2.1 +/- 0.6 2.2 +/- 0.7 1.12 1.21

< 2.0

< 1.9

< 4.8

< 6.2

< 2.2

< 2.1

< 2.3

< 1.7

< 4.1

< 4.3

< 3.1

< 4.2

< 2.5

< 2.7

< 2.8

< 2.3

< 4.2

< 6.5 67 06-01-16 KSW-2831

< 0.8 1.2 +/- 0.6 1.2 +/- 0.6 1.11

< 3.4

< 4.1

< 2.6

< 2.5

< 3.7

< 5.7

< 4.5

< 5.2

< 4.7 06-01-16 KSW-2832

< 0.7 1.9 +/- 0.7 1.9 +/- 0.7 1.13

< 2.3

< 5.5

< 2.4

< 1.6

< 2.7

< 3.8

< 2.6

< 1.9

< 3.5

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

K-9 (Raw)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-9 (Tap)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 07-05-16 08-01-16 KSW-3354 KSW-4081

< 0.7

< 0.6 1.2 +/- 0.4 1.9 +/- 0.5 1.2 +/- 0.4 1.9 +/- 0.5 1.06 1.16

< 2.7

< 1.9

< 3.7

< 4.6

< 2.7

< 2.3

< 1.7

< 1.2

< 3.8

< 1.6

< 3.3

< 3.5

< 2.4

< 2.7

< 2.9

< 2.7

< 3.3

< 7.8 07-05-16 08-01-16 KSW-3355 KSW-4082

< 0.7

< 0.8 1.0 +/- 0.4 2.0 +/- 0.6 1.0 +/- 0.4 2.0 +/- 0.6 1.11 1.21

< 3.3

< 1.5

< 5.6

< 4.0

< 3.0

< 2.8

< 5.7

< 1.7

< 4.1

< 5.0

< 5.3

< 3.8

< 5.7

< 3.4

< 4.1

< 1.7

< 5.2

< 6.5 68 09-06-16 KSW-4738

< 0.7 0.6 +/- 0.4 0.6 +/- 0.4 1.03

< 2.4

< 2.7

< 2.4

< 2.0

< 3.9

< 2.9

< 3.2

< 2.9

< 2.7 09-06-16 KSW-4739

< 0.7 1.3 +/- 0.4 1.3 +/- 0.4 1.06

< 3.1

< 3.3

< 2.9

< 1.7

< 4.7

< 1.9

< 2.7

< 2.8

< 2.6

KPS Table 24. Surface water samples, analyses for gross beta, potassium-40, and gamma-emitting isotopes (continued).

K-9 (Raw)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-9 (Tap)

Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 10-03-16 11-01-16 KSW-5313 KSW-5979

< 0.5

< 0.6 1.7 +/- 0.5 2.2 +/- 0.5 1.7 +/- 0.5 2.2 +/- 0.5 1.16 1.16

< 2.3

< 3.4

< 5.0

< 5.9

< 2.1

< 2.9

< 2.3

< 3.9

< 2.4

< 5.0

< 2.5

< 4.4

< 3.0

< 4.5

< 2.9

< 4.1

< 4.2

< 5.1 10-03-16 11-01-16 KSW-5314 KSW-5980

< 0.7

< 0.8 1.9 +/- 0.5 1.0 +/- 0.2 1.9 +/- 0.5 1.0 +/- 0.2 1.18 1.13

< 5.0

< 2.8

< 8.6

< 5.3

< 3.0

< 1.8

< 4.1

< 1.9

< 6.1

< 3.0

< 4.4

< 2.3

< 6.1

< 2.3

< 6.6

< 3.9

< 4.1

< 4.0 69 12-01-16 KSW-6647

< 0.7 1.2 +/- 0.3 1.2 +/- 0.3 1.13

< 3.8

< 3.3

< 3.9

< 3.5

< 3.6

< 4.3

< 3.8

< 4.6

< 2.3 12-01-16 KSW-6648

< 0.6 1.4 +/- 0.3 1.4 +/- 0.3 1.19

< 4.3

< 3.4

< 4.2

< 4.3

< 7.4

< 4.8

< 6.7

< 6.6

< 3.2

KPS Table 24. Surface water, analyses for gross beta, potassium-40 and gamma-emitting isotopes (continued).

Indicator K-14a Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 K-14b Date Collected Lab Code Gross beta Suspended Solids Dissolved Solids Total Residue K-40 (ICP)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Description and Concentration (pCi/L) 01-04-16 02-01-16 KSW-94 KSW-448

< 0.7

< 0.8 2.4 +/- 0.5 1.5 +/- 0.4 2.4 +/- 0.5 1.5 +/- 0.4 1.35 1.38

< 3.0

< 2.3

< 3.9

< 3.2

< 2.1

< 1.7

< 2.1

< 1.7

< 2.5

< 3.3

< 2.7

< 2.5

< 3.1

< 2.7

< 1.9

< 2.5

< 5.7

< 3.3 01-04-16 02-01-16 KSW-95 KSW-449

< 0.7

< 0.7 2.9 +/- 0.5 1.4+/-0.4 2.9 +/- 0.5 1.4 +/- 0.4 1.38 1.36

< 4.0

< 3.3

< 4.5

< 5.4

< 3.2

< 3.5

< 4.2

< 3.7

< 6.3

< 2.8

< 5.9

< 2.9

< 5.0

< 3.3

< 5.5

< 2.8

< 5.8

< 4.0 70 03-01-16 KSW-860

< 0.7 1.5 +/- 0.3 1.5 +/- 0.3 1.45

< 2.9

< 2.7

< 1.4

< 2.0

< 3.0

< 2.3

< 3.2

< 2.5

< 3.9 03-01-16 KSW-861

< 0.8 2.3 +/- 0.5 2.3 +/- 0.5 1.54

< 2.4

< 6.0

< 1.9

< 2.3

< 3.9

< 3.5

< 2.8

< 2.8

< 1.9

KPS Table 24. Surface water, analyses for gross beta, potassium-40 and gamma-emitting isotopes (continued}.

Sample Description and Concentration (pCi/L)

Indicator K-14a Date Collected 04-04-16 05-02-16 06-01-16 Lab Code KSW-1362 KSW-2141 KSW-2833 Gross beta Suspended Solids

< 0.7

< 0.7

< 0.7 Dissolved Solids 2.5 +/- 0.4 3.1 +/- 0.7 1.2 +/- 0.6 Total Residue 2.5 +/- 0.4 3.1 +/- 0.7 1.2 +/- 0.6 K-40 (ICP) 1.94 1.75 1.16 Mn-54

< 2.1

< 1.7

< 3.9 Fe-59

< 4.4

< 6.0

< 9.6 Co-58

< 1.9

< 2.1

< 4.7 Co-60

< 1.4

< 1.9

< 6.4 Zn-65

< 2.9

< 2.1

< 2.8 Zr-Nb-95

< 2.3

< 4.0

< 4.3 Cs-134

< 2.3

< 2.3

< 4.8 Cs-137

< 1.9

< 3.0

< 4.4 Ba-La-140

< 5.9

< 6.6

< 4.0 K-14b Date Collected 04-04-16 05-02-16 06-01-16 Lab Code KSW-1363 KSW-2142 KSW-2834 Gross beta Suspended Solids

< 0.8

< 0.7

< 0.8 Dissolved Solids 2.3 +/- 0.4 3.3 +/- 0.8 2.3 +/- 0.7 Total Residue 2.3 +/- 0.4 3.3 +/- 0.8 2.3 +/- 0.7 K-40 (ICP) 1.91 1.81 1.15 Mn-54

< 1.9

< 1.6

< 2.4 Fe-59

< 6.0

< 4.2

< 3.4 Co-58

< 1.8

< 2.1

< 2.3 Co-60

< 1.7

< 2.5

< 2.4 Zn-65

< 5.9

< 3.1

< 3.4 Zr-Nb-95

< 2.7

< 2.6

< 4.2 Cs-134

< 2.8

< 2.7

< 2.7 Cs-137

< 2.1

< 2.6

< 3.7 Ba-La-140

< 3.1

< 3.2

< 4.3 71

KPS Table 24. Surface water, analyses for gross beta, potassium-40 and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/L)

Indicator K-14a Date Collected 07-05-16 08-01-16 09-06-16 Lab Code KSW-3356 KSW-4083 KSW-4740 Gross beta Suspended Solids

< 0.7

< 0.5

< 0.7 Dissolved Solids 1.0 +/- 0.4 2.1 +/- 0.5 2.4 +/- 0.5 Total Residue 1.0+/-0.4 2.1 +/- 0.5 2.4 +/- 0.5 K-40 (ICP) 1.12 1.21 1.12 Mn-54

< 2.1

< 2.7

< 2.8 Fe-59

< 4.2

< 6.5

< 4.4 Co-58

< 2.3

< 1.8

< 1.9 Co-60

< 1.8

< 1.4

< 2.7 Zn-65

< 3.2

< 3.1

< 2.2 Zr-Nb-95

< 2.3

< 3.3

< 2.4 Cs-134

< 2.6

< 3.3

< 3.8 Cs-137

< 2.5

< 1.7

< 2.6 Ba-La-140

< 3.9

< 8.6

< 2.9 K-14b Date Collected 07-05-16 08-01-16 09-06-16 Lab Code KSW-3357 KSW-4084 KSW-4741 Gross beta Suspended Solids

< 0.7

< 0.5 1.3 +/- 0.4 Dissolved Solids 1.1 +/- 0.4 1.9 +/- 0.6 2.7 +/- 0.5 Total Residue 1.1 +/- 0.4 1.9 +/- 0.6 4.0 +/- 0.6 K-40 (ICP) 1.11 1.19 1.11 Mn-54

< 3.5

< 1.9

< 3.1 Fe-59

< 4.7

< 5.8

< 5.0 Co-58

< 2.3

< 2.5

< 3.7 Co-60

< 1.7

< 1.4

< 2.9 Zn-65

< 4.7

<4.6

< 6.5 Zr-Nb-95

< 4.8

< 4.1

< 4.1 Cs-134

< 3.2

< 2.9

< 4.7 Cs-137

< 3.1

< 2.4

< 4.0 Ba-La-140

< 2.3

< 7.6

< 1.9 72

KPS Table 24. Surface water, analyses for gross beta, potassium-40 and gamma-emitting isotopes (continued).

Sample Description and Concentration (pCi/L)

Indicator K-14a Date Collected 10-03-16 11-01-16 12-01-16 Lab Code KSW-5315 KSW-5981 KSW-6649 Gross beta Suspended Solids

< 0.7

< 0.7

< 0.8 Dissolved Solids 2.9 +/- 0.6 1.9 +/- 0.2 1.7 +/- 0.3 Total Residue.

2.9 +/- 0.6 1.9 +/- 0.2 1.7 +/- 0.3 K-40 (ICP) 1.25 1.33 1.96 Mn-54

< 1.8

< 4.8

< 2.5 Fe-59

< 3.3

< 7.8

< 3.6 Co-58

< 2.7

< 2.8

< 2.3 Co-60

< 1.2

< 4.2

< 3.4 Zn-65

< 4.2

< 4.4

< 4.4 Zr-Nb-95

< 3.9

< 2.7

< 2.8 Cs-134

< 2.5

< 5.4

< 4.4 Cs-137

< 2.2

< 5.1

< 4.3 Ba-La-140

< 4.6

< 6.5

< 3.2 K-14b Date Collected 10-03-16 11-01-16 12-01-16 Lab Code KSW-5316 KSW-5982 KSW-6650 Gross beta Suspended Solids

< 0.8

< 0.7

< 0.4 Dissolved Solids 2.8 +/- 0.5 2.5 +/- 0.7 2.1 +/- 0.4 Total Residue 2.8 +/- 0.5 2.5 +/- 0.7 2.1 +/- 0.4 K-40 (ICP) 1.26 1.30 1.94 Mn-54

< 3.4

< 3.7

< 3.5 Fe-59

< 5.4

< 7.3

< 2.4 Co-58

< 2.8

< 2.7

< 3.2 Co-60

< 3.6

< 3.1

< 2.6 Zn-65

< 5.4

< 2.8

< 5.3 Zr-Nb-95

< 2.7

< 4.2

< 4.0 Cs-134

< 3.9

< 3.9

< 3.4 Cs-137

< 3.3

< 3.4

< 3.9 Ba-La-140

< 3.0

< 4.3

< 3.1 73

KPS Table 25. Surface water, analyses for tritium, strontium-89 and strontium-90.

Collection: Quarterly composites of monthly samples.

Location and Collection Period Indicator K-1a 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter K-1b 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter K-1d 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter K-1e 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code KSW -1081 KSW -3065 KSW -4851 KSW -6810 KSW -1082 KSW -3066 KSW -4852 KSW -6811 KSW -1083 KSW -3067 KSW -4853 KSW -6812 KSW -1084 KSW -3068 KSW -4854 KSW -6813 74 H-3

< 149

< 148

< 149

< 160

< 149

< 148

< 149

< 160

< 149

< 148

< 149

< 160

< 149

< 146

< 173

< 160 Concentration pCi/L Sr-89

< 1.3

< 1.3

< 1.9

< 1.1

< 1.4

< 1.7

<2.0

< 1.2

< 1.2

< 1.3

< 1.6

< 1.0

< 1.2

< 1.1

< 1.3

< 1.0 Sr-90

< 0.5

< 0.5

< 0.7

< 0.6

< 0.5

< 0.6

< 0.7

< 0.6

< 0.5

< 0.5

< 0.6

< 0.5

< 0.4

< 0.4

< 0.4

< 0.5

KPS Table 25. Surface water, analyses for tritium, strontium-89 and strontium-90 (continued).

Location and Concentration pCi/L Collection Period H-3 Sr-89 Sr-90 Indicator K-14a 1st Quarter KSW -1088

< 149

< 1.1

< 0.4 2nd Quarter KSW -3072

< 146

< 1.3

< 0.5 3rd Quarter KSW -4858

< 149

< 1.5

< 0.5 4th Quarter KSW -6817

< 160

< 1.4

< 0.5 K-14b 1st Quarter KSW -1089

< 149

< 1.1

< 0.4 2nd Quarter KSW -3073

< 146

< 1.4

< 0.6 3rd Quarter KSW -4859

< 149

< 1.3

< 0.5 4th Quarter KSW -6818

< 160

< 1.0

< 0.5 K-1k 1st Quarter KSW -1086

< 149

< 1.4

< 0.5 2nd Quarter KSW -3069

< 148

< 1.1

< 0.4 3rd Quarter KSW -4855

< 173

< 1.3

< 0.5 4th Quarter KSW -6814

< 160

< 1.0

< 0.6 Control K-9 1st Quarter KSW -1087 (Raw)

< 149

< 1.1

< 0.4 KSW -1088 (Tap)

< 149

< 1.1

< 0.4 2nd Quarter KSW -3070 (Raw)

< 148

< 1.4

< 0.6 KSW -3071 (Tap)

< 148

< 1.7

< 0.6 3rd Quarter KSW -4856 (Raw)

< 149

< 1.5

< 0.5 KSW -4857 (Tap)

< 149

< 1.5

< 0.5 4th Quarter KSW -6815 (Raw)

< 160

< 1.1

< 0.6 KSW -6816 (Tap)

< 160

< 1.2

< 0.6 75

Table 26.

Collected Lab Code Type Portion Gross beta Sr-89 Sr-90 K-40 Mn-54 Fe-59 Co-58 Co-60 Cs-134 Cs-137 Collected Lab Code Type Portion Gross beta Sr-89 Sr-90 K-40 Mn-54 Fe-59 Co-58 Co-60 Cs-134 Cs-137 KPS Fish, collected at K-1d, analyses for gross beta, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Three times a year Sample Description and Concentration (pCi/g wet) 04-21-16 KF-2072 Brown Trout 3.45 +/- 0.07 NA 8

NA 3.39 +/- 0.44

< 0.016

< 0.072

< 0.026

< 0.018

< 0.020

< 0.021 2.96 +/- 0.87

< 0.33 0.18 +/- 0.07 NA 8

NA NA NA NA NA NA 12-01-16 KF-6566 Coho Salmon Flesh Bones 4.51 +/- 0.09 2.13 +/- 0.49 NA a

< 0.18 NA

< 0.11 3.76 +/- 0.40 NA 8

< 0.009 NA

< 0.029 NA

< 0.015 NA

< 0.010 NA

< 0.016 NA

< 0.013 NA 09-29-16 KF-5173 Salmon Flesh 4.04 +/- 0.08 NA 8

NA 3.58 +/- 0.62

< 0.030

< 0.059

< 0.024

< 0.017

< 0.030

< 0.037 4.48 +/- 0.74

< 0.25 0.18 +/- 0.06 NA 8

NA NA NA NA NA NA a NA= Not analyzed; analyses not required.

76

KPS Table 27.

Slime or aquatic vegetation, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection: Semiannually Sample Description and Concentration (pCi/g wet)

Indicators Control Location K-1a K-1b K-1d K-9 Date Collected 06-01-16 06-01-16 06-01-16 06-01-16 Lab Code KSL-2757 KSL-2758 KSL-2759 KSL-2762 Gross beta 4.56 +/- 0.09 5.03 +/- 0.09 1.18 +/- 0.05 5.99 +/- 0.12 Sr-89

< 0.006

< 0.006

< 0.014

< 0.015 Sr-90

< 0.002

< 0.002 0.007 +/- 0.003

< 0.007 Be-7 0.53 +/- 0.06 0.15 +/- 0.049 0.44 +/- 0.06 0.16 +/- 0.06 K-40 3.89 +/- 0.14 4.73 +/- 0.14 3.80 +/- 0.13 4.49 +/- 0.13 Mn-54

< 0.004

< 0.004

< 0.005

< 0.005 Co-58

< 0.005

< 0.005

< 0.004

< 0.005 Co-60

< 0.005

< 0.005

< 0.005

< 0.003 Nb-95

< 0.007

< 0.006

< 0.007

< 0.005 Zr-95

< 0.005

< 0.010

< 0.010

< 0.009 Ru-103

< 0.004

< 0.005

< 0.003

< 0.006 Ru-106

< 0.042

< 0.035

< 0.039

< 0.041 Cs-134

< 0.005

< 0.005

< 0.004

< 0.004 Cs-137

< 0.005

< 0.004 0.013 +/- 0.005

< 0.004 Ce-141

< 0.011

< 0.008

< 0.011

< 0.012 Ce-144

< 0.033

< 0.036

< 0.029

< 0.034 Sb-125

< 0.026

< 0.025

< 0.017

< 0.021 Location K-1e K-1k K-14 Date* Collected 06-01-16 06-01-16 06-01-16 Lab Code KSL-2760 KSL-2761 KSL-2763 Gross beta 2.87 +/- 0.15 4.44 +/- 0.08 1.71 +/- 0.10 Sr-89

< 0.036

< 0.004

< 0.022 Sr-90

< 0.014

< 0.002

< 0.009 Be-7 1.32 +/- 0.05

< 0.05 0.91 +/- 0.07 K-40 1.90 +/- 0.08 3.49 +/- 0.13 2.44 +/- 0.11 Mn-54

< 0.003

< 0.005

< 0.005 Co-58

< 0.003

< 0.005

< 0.005 Co-60

< 0.004

< 0.002

< 0.005 Nb-95

< 0.004

< 0.006

< 0.006 Zr-95

< 0.005

< 0.009

< 0.010 Ru-103

< 0.004

< 0.006

< 0.003 Ru-106

< 0.026

< 0.043

< 0.041 Cs-134

< 0.003

< 0.005

< 0.004 Cs-137 0.005 +/- 0.003

< 0.005 0.011 +/- 0.005 Ce-141

< 0.008

< 0.013

< 0.013 Ce-144

< 0.021

< 0.036

< 0.035 Sb-125

< 0.013

< 0.023

< 0.024 77

KPS Table 27.

Slime or aquatic vegetation, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection: Semiannually Sample Description and Concentration (pCi/g wet)

Indicators Control Location K-1b K-1b K-1a Date Collected 06-16-16 06-23-16 08-01-16 Lab Code KSL-3378 KSL-3379 KSL-4041 Gross beta 1.38 +/- 0.07 1.33 +/- 0.10 5.28 +/- 0.11 Sr-89

< 0.010

< 0.041

< 0.02 Sr-90 0.016 +/- 0.003 0.020 +/- 0.010

< 0.007 Be-7 0.22 +/- 0.06 1.37 +/- 0.06

< 0.11 K-40 1.84 +/- 0.09 2.39 +/- 0.08 3.96 +/- 0.17 Mn-54

< 0.002

< 0.003

< 0.006 Co-58

< 0.006

< 0.004

< 0.008 Co-60

< 0.003

< 0.003

< 0.005 Nb-95

< 0.007

< 0.006

< 0.014 Zr-95

< 0.007

< 0.005

< 0.016 Ru-103

< 0.006

< 0.005

< 0.009 Ru-106

< 0.025

< 0.026

< 0.056 Cs-134

< 0.003

< 0.003

< 0.007 Cs-137

< 0.004 0.011 +/- 0.003

< 0.008 Ce-141

< 0.015

< 0.012

< 0.025 Ce-144

< 0.021

< 0.021

< 0.039 Sb-125

< 0.019

< 0.012

< 0.030 Location K-1d K-1k Date Collected 08-01-16 08-01-16 Lab Code KSL-4042 KSL-4043 Gross beta 2.84 +/- 0.22 6.27 +/- 0.12 Sr-89

< 0.056

< 0.018 Sr-90 0.026 +/- 0.013 0.008 +/- 0.004 Be-7 2.29 +/- 0.20 0.18+/-0.05 K-40 2.63 +/- 0.20 4.60+/-0.17 Mn-54

< 0.008

< 0.005 Co-58

< 0.008

< 0.007 Co-60

< 0.018

< b.007 Nb-95

< 0.019

< 0.012 Zr-95

< 0.013

< 0.011 Ru-103

< 0.013

< 0.007 Ru-106

< 0.045

< 0.050 Cs-134

< 0.007

< 0.005 Cs-137 0.024 +/- 0.010

< 0.006 Ce-141

< 0.023

< 0.018 Ce-144

< 0.039

< 0.047 Sb-125 0.054 +/- 0.018

< 0.032 78

KPS Table 27.

Slime or aquatic vegetation, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection: Semiannually Sample Description and Concentration (pCi/g wet)

Indicators Control Location K-1b K-1b K-14 K-9 Date Collected 09-06-16 09-06-16 09-06-16 09-06-16 Lab Code KSL-4728 KSL-4729 KSL-4732 KSL-4730 Gross beta 1.72 +/- 0.08 3.15 +/- 0.12 2.52 +/- 0.12 6.30 +/- 0.10 Sr-89

< 0.018

< 0.035

< 0.025

< 0.017 Sr-90 0.030 +/- 0.006

< 0.014

< 0.011 0.018 +/- 0.005 Be-7 0.29 +/- 0.06 0.83 +/- 0.09 0.91 +/- 0.07 0.58 +/- 0.11 K-40 1.00 +/- 0.07 2.82 +/- 0.11 3.03 +/- 0.12 4.94 +/- 0.19 Mn-54

< 0.004

< 0.004

< 0.005

< 0.008 Co-58

< 0.003

< 0.006

< 0.005

< 0.008 Co-60

< 0.003

< 0.004

< 0.005

< 0.007 Nb-95

< 0.006

< 0.009

< 0.009

< 0.013 Zr-95

< 0.010

< 0.012

< 0.006

< 0.009 Ru-103

< 0.004

< 0.004

< 0.006

< 0.009 Ru-106

< 0.032

< 0.038

< 0.028

< 0.047 Cs-134

< 0.003

< 0.005

< 0.004

< 0.006 Cs-137

< 0.004 0.010 +/- 0.004 0.008 +/- 0.004

< 0.007 Ce-141

< 0.010

< 0.015

< 0.015

< 0.017 Ce-144

< 0.028

< 0.035

< 0.023

< 0.047 Sb-125

< 0.016

< 0.018

< 0.020

< 0.030 Location K-1d Date Collected 10-21-16 Lab Code KSL-5985 Gross beta 0.87 +/- 0.03 Sr-89

< 0.015 Sr-90

< 0.007 Be-7 0.27 +/- 0.04 K-40 2.00 +/- 0.07 Mn-54

< 0.003 Co-58

< 0.003 Co-60

< 0.003 Nb-95

< 0.006 Zr-95

< 0.008 Ru-103

< 0.003 Ru-106

< 0.022 Cs-134

< 0.003 Cs-137 0.012 +/- 0.003 Ce-141

< 0.011 Ce-144

< 0.018 Sb-125

< 0.015 79

KPS Table 28.

Bottom sediment samples, analyses for gross beta, strontium-89, strontium-90, and gamma-emitting isotopes.

Collection: May and November Sample Description and Concentration (pCi/g dry)

Indicator Control Location K-1c K-1d K-1j K-14 K-9 Collection Date 05-02-16 05-02-16 05-02-16 05-02-16 05-02-16 Lab Code KBS-2143 KBS-2144 KBS-2145 KBS-2147 KBS-2146 Gross beta 6.08 +/- 1.04 8.74 +/- 1.18 9.66 +/- 1.23 9.59 +/- 1.26 19.04 +/- 1.39 Sr-89

< 0.073

< 0.050

< 0.050

< 0.058

< 0.066 Sr-90

< 0.029

< 0.020

< 0.021 0.033 +/- 0.014

< 0.028 K-40 5.79 +/- 0.49 4.41 +/- 0.48 6.86 +/- 0.55 6.80 +/- 0.39 13.$3 +/- 0.83 Co-58

< 0.030

< 0.027

< 0.029

< 0.022

< 0.038 Co-60

< 0.017

< 0.017

< 0.011

< 0.011

< 0.024 Cs-134

< 0.013

< 0.017

< 0.012

< 0.011

< 0.020 Cs-137

< 0.016

< 0.016

< 0.017

< 0.014

< 0.027 Location Collection Date 11-01-16 11-01-16 11-01-16 11-01-16 11-01-16 Lab Code KBS-5988 KBS-5989 KBS-5990 KBS-5992 KBS-5991 Gross beta 9.75 +/- 1.53 10.26 +/- 1.63 9.18 +/- 1.52 8.04 +/- 1.60 18.80 +/- 1.98 Sr-89

< 0.073

< 0.086

< 0.060

< 0.082

< 0.071 Sr-90

< 0.032

< 0.037

< 0.025

< 0.034

< 0.031 K-40 6.52 +/- 0.58 5.98 +/- 0.41 6.05 +/- 0.61 3.66 +/- 0.48 12.30 +/- 0.72 Co-58

< 0.024

< 0.018

< 0.026

< 0.021

< 0.030 Co-60

< 0.012

< 0.013

< 0.014

< 0.012

< 0.023 Cs-134

< 0.016

< 0.011

< 0.018

< 0.015

< 0.017 Cs-137

< 0.018

< 0.020

< 0.022

< 0.017

< 0.027 80

2016 Annual Radiological Environ*01ental Operating Report Kewaunee Power Station Part !IL Corrective Actions written during reporting period Dominion Energy Kewaunee, Inc.

CR - Power found off at K-2 Environmental air...

lifil Kewaunee CRS > CR: Power found off at K-2 Environmental air sampler CR.__ID Short description Site Discovery Date{rlme Submitter Submitters Dept Supervisor Unit 1 Mode Unit ISFSI?

Revision #

Long Description Inltial Actions Recom Actlons:

MR Function Exists:

addltlonal Contacts Is this CR associated with Berle Acid Corrosion Control Program Y/N Is the Boric Acid wet, glistening moist or dripping? (ER-AP-BAC-101)

Is the boric acid deposit excessive? (ER-AP-BAC-01)

Is the boric acid dlscolored (e.g, non-white) or Is there any visible degredatlon? (ER-AP-BAC-01)

Does the boric acid appear to originate froma crack p!nhole leek or through a welded connection? (ER-AP-BAC-101)

Page 1of1 669 Power found off at K-2 Environmental air sampler Kewaunee 6/28/2016 9:00 AM Paul A Simon (Generation - 4)CI

2. Radiation Protection Dan J Shannon (Generation - 4) ~l DEF No Power found off at K-2 Environmental air sampler. It appears that power was not turned back on alter 6/21/16 filter change. AJr sampler Is now working as expected.

Notifed Chemistry supervision. Replaced filter and returned power to air sampler

  • Document this event In the 2016 Environmental Monitoring Report (Holschbach/Shannan). Recommended due date end of May 2017.

No No No No No Does the boric acid appear to come from under Insulation or has It run under insulation or Is the source of the leak unknown? (ER-AP-BAC-101)

No Equipment Location Equipment Description Plant System OP-AA-102 Review Reqd?

Operability Assesment Operability Comments Functlonallty Assessment Reportable Condition Reportability Comments Is Equipment Important to Emergency Response WM-KW-100 values 0/RComments Significance (screening)

Potential Repeat (screening)

Previous Issue CRT Comments Work Order#

Comments Status Content Type: Item Version: 17.0 Created at 6/29/2016 11:13 AM by Paul A Simon (Generation - 4) -*

Last modified at 7/12/2016 s:oo PM by System Account No N/A N/A No No Yes Search by "K-2 Environmental Air Sampler" identified the following:

CR88 - K-2 Environmental Alr sampler found not working (07/28/2015)

K-2 Environmental Air Sampler was returned to service on 06/28/2016.

CA(249) to RP (Holschbach/Shannon) to include K-2 Envlronmental Air Sampler being out of service In the 2016 Annual RadJologlcal Environmental Operating Report. Due Date: 05/15/2017 Pending Close http://generationdomnet/sites/kpscrs/Lists/CR/DispForm.aspx?ID=689&Source=http%3A...

3/15/2017

This Page lntentionallyleft Blank

CR - Environmental air samplers found not running...

l~I

~

Kewaunee CRS

  • CR: Environmenta.I air samplers found not running CR_ID Short description Site Discovery oate{Time Submitter Submitters Dept Supervisor Unit 1 Mode Unit ISFSI?

Revision#

Long Description Initial Actions Recom Actions:

MR Function Exists:

addltlonal Canta~

Tag#:

Is this CR associated with Boric Acid Corrosion Control Program Y/N Is the Boric Acid wet, glistening moist or dripping? (ER-AP-BAC-101)

Is the boric acid deposit excessive? (ER-AP-BAC-01) is the boric acid discolored (e.g, non-white) or Is there any visible degredation? (ER-AP-BAC-01)

Does the boric acid appear to originate froma crack pinhole leek or through a welded connection? (ER-AP-BAC-101)

Page 1of2 746 Environmental air samplers found not running Kewaunee 8/16/2016 7:00 AM Paul A Simon (Generation - 4)!;~;1

2. Radiation Protection Dan J Shannon (Generation - 4) ~

N/A No Two of the six environmental air samplers were found not running: K-31 (East Krok substation) and K 41 (Point Beach EOF in Green Bay). The fuses were blown. The hour meter on both of them were noted to be at approximately 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br />, so that means they ran most of the week and failed around 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before replacement. Enough sampling time was accumulated to send the sample media to the envlronmental monitoring program lab for analysis.

Contact SME and RP supervision. RP Instrument Technician replaced both air sample pumps. Initial investigation shows that both pump motors had seized up and required repair.

CA to document this event in the 2016 Annual Radiological Environmental Operating Report (Holschbach/Shannon) -

due date May 31, 2017.

No No No No No Does the boric acid appear to come from under insulatlon or has it run under lnsulatlon or is the source of the leak unknown? (ER-AP-BAC-101)

No Equipment Location Equipment Description Plant System OP-M-102 Review Reqd?

Operability Assesment Operability Comments Functionality Assessment Reportable Condition Reportabllity Comments Is Equipment Important to Emergency Response WM-KW-100 values 0/R Comments Significance (screening)

Potentfal Repeat (screening)

Previous Issue CRT Comments No N/A N/A N/A No No Yes CR Search by "Environmental Air Sampler" Identified the folrowlng:

CR689 - Power found off at K-2 Environmental air sampler (06/28/2016)

CR338 - Hour Meter on Environmental Air Sampler K-41 Was Not Reset (11/17/2015)

CR88 - K-2 Envlromental Air sampler found not working (07 /28/2015)

CR547860 - K-31 Environmental Air Sampler lost power (05/06/2014)

RP Tech replaced both pumps and will repair the non-functional pumps.

CA(268) to RP (Holschbach/Shannon) to document this event in the 2016 Annual RadfologJcal Environmental Operating Report. Due Date: 05/31/2017 http:// generationdomnet/sites/kpscrs/Lists/CR/DispF orm.aspx?ID=7 46&Source=http%3A...

3/15/2017

CR - Environmental air samplers found not running...

Work Order#

Comments Status Content Type: Item Version: 13.0 Created at 8/18/2016 9:02 AM by Paul A Simon (Generation* 4) 1?1 Last modified at 8/31/2016 5:04 PM by System Account Pending Close http:// generationdomnet/sites/kpscrs/Lists/CR/DispF orm.aspx?ID=7 46&Source=http%3A...

3/15/2017

CR-Three REMP Environmental Air Samplers Found...

m Kewaunee CRS > CR: Three REMP Environmental Air Samplers Found Not Running CR.JD Short description Site Discovery Date{Time Submitter Submitters Dept Supervisor Unit 1 Mode Unit ISFSl7 Revision#

Long Description Initial Actions Recom Actions:

MR Function Exists:

additional Contacts Tag#:

Is this CR associated with Boric Acid Corrosion Control Program Y/N Is the Boric Acid wet, glistening moist or dripping? (ER-AP-BAC-101)

Is the boric add deposit excessive? (ER-AP-BAC-01)

Is the boric acid discolored (e.g, non-white) or Is there any visible degredation? (ER-AP-BAC-01)

Does the boric acid appear to originate froma crack pinhole leek or through a welded connection? (ER-AP-BAC-101)

Page 1of2 756 Three REMP Environmental Air Samplers Found Not Running Kewaunee 8/22/2016 9:00 AM Darryl M Holschbach (Generation - 4) [j!J

2. Radiation Protection Dan J Shannon (Generation -4)riJ N/A No Three of the six Radiological Environmental Monitoring Program (REMP) air samplers were found not running on 8/22/16. The environmental air samplers are required by the REMP. Sample collection is performed in accordance with procedure SP-63-164, Environmental Sample Collection.

Air sample pumps at the (allowing locations were found not running prior to a normal weekly run time of 168 hour0.00194 days <br />0.0467 hours <br />2.777778e-4 weeks <br />6.3924e-5 months <br />s:

-Klf at Kewaunee Power Station Meteorological Tower failed after 124 hours0.00144 days <br />0.0344 hours <br />2.050265e-4 weeks <br />4.7182e-5 months <br />.

-K-31 at East Krok Electric Substation failed after lOS Hours

-K41 at Point Beach Emergency off-site Facility (EOF) In Green Bay failed after 86 Hours.

This Is a repeat occurrence (see CR 746). A faulty batch/lot of carbon blades used for air sample pump annual maintenance is suspected to be the cause. As a follow on action to this previous issue, the sample pumps at all six locations were checked and verified to be running properly on 8/19/16. All three failures occurred after this check was completed.

The failed sample pumps have been replaced with rebuilt sample pumps. The sample pumps are being rebuilt with a different batch/lot of carbon vanes.

Contacted SME and RP supervision. RP Instrument Technician replaced all three air sample pumps. More frequent monitoring of air sampler performance In the field is In progress. There Is also telemetric monitoring on the pumps which notifies RP/CY Personel if pump failure occurs.

CA to document this event in the 2016 Annual Radlolog!cal Environmental Operating Report (Holschbach/Shannon)-

due date May 31, 2017.

No No No No No Does the boric acid appear to come from under Insulation or has It run under Insulation or Js the source of the leak unknown? (ER-AP-BAC-101)

No Equipment Location Equipment Description Plant System 63 OP-AA-102 Review Reqd?

No Operablllty Assesment N/A Operability Comments N/A Functionality Assessment N/A Reportable Condition No Reportabllity Comments http://generationdomnet/sites/kpscrs/Lists/CR/DispForm.aspx?ID=756&Source=http%3A...

3/15/2017

CR - Three REMP Environmental Air Samplers Found...

Is Equipment Important to Emergency Response WM-KW-100 values O/R Comments Significance (screening)

PotentJal Repeat (screening)

Previous Issue CRT Comments Work Order#

Comments Status Content Type: Item Version: 17.0 Created at 8/24/2016 10:57 AM by Danyl M Ho~cllbacll (Generation - 4) l!!J Last modified at 8/31/2016 5:08 PM by System Account Page 2 of2 No Yes CR Search by "Environmental Air Sampler" Identified the following:

CR746 - Environmental air samplers found not running (08/16/2016)

CR689 - Power found off at K-2 Environmental air sampler (06/28/2016)

CR338 - Hour Meter on Environmental Air Sampler K-.41 Was Not Reset (11/17/2015)

CRBB - K-2 Envlromental Air sampler found not working (07/28/2015)

CR547860 - K-31 Environmental Afr Sampler lost power (05/06/2014)

As stated, all 3 sample pumps were replaced with rebuilt pumps using a different lot of carbon blades.

CA(269) to RP (Holschbach/Shannon) to document this event In the 2016 Annual Radlologlcal Environmental Operating Report. Due Date: 05/31/2017 Pending Close http:// generationdomnet/sites/kpscrs/Lists/CR/DispF orm.aspx?ID=7 5 6&Source=http%3A...

3/15/2017

CR-K-8 REMP Environmental Air Samplers Found...

li1Bl Kewaunee CRS > CR: K-8 REMP Environmental Air Samplers Found Not Running

-~

CR._ID Short description Site Discovery Date{Time Submitter Submitters Dept Supervisor Unit 1 Mode Unit ISFS!?

Revision #

Long Description Initial Actions Recom Actions:

MR Function Exists:

additional Contacts Tag#:

Is th ls CR associated with Boric Acid Corrosion Control Program Y/N Is the Boric Acid wet, glistening moist or dripping? (ER-AP-BAC-101)

Is the boric acid deposit excessive? (ER-AP-BAC-01)

Is the boric acid discolored (e.g, non-white) or is there any vlslble degredatlon? (ER-AP-BAC-01)

Does the boric acid appear to originate froma crack pinhole leek or through a welded connection? (ER-AP-BAC-101)

Page 1of2 784 K-8 REMP Environmental Air Samplers Found Not Running Kewaunee 9/20/2016 7:40 AM Darryl M HoJschbach (Generation - 4) {ii

2. Radiation Protection Dan J Shannon (Generation - 4)@!!

DEF No One of the six Radiological Environmental Monitoring Program (REMP) air samplers was found not running on 9/20/16. The environmental air samplers are required by the REMP. Sample collection is performed in accordance with procedure SP-63-164, Environmental Sample Collection.

The air sample pump at location K-8 was found not running prior to a normal weekly run time of 168 hours0.00194 days <br />0.0467 hours <br />2.777778e-4 weeks <br />6.3924e-5 months <br />.

K-8 at Saint Isadore the Farmer Church, 18424 Tisch Mills Rd, Tisch Mills stopped running after 93 hours0.00108 days <br />0.0258 hours <br />1.537698e-4 weeks <br />3.53865e-5 months <br />.

The sample pump has been replaced with a rebuilt sample pump on 9/21/16 Contacted SME and RP supervision. RP Instrument Technician replaced the air sample pump CA to document this event In the 2016 Annual Radiological Environmental Operating Report (Holschbach/Shannon) -

due date May 31, 2017.

No No No No No Does the boric acid appear to come from under lnsulatlon or has It run under Insulation or Is the source of the leak unknown? (ER-AP-BAC-101)

No Equipment Location Equipment Description Plant System OP-M-102 Review Reqd?

Operability Assesment Operability Comments Functionality Assessment Reportable Condition Reportablllty Comments Is Equipment Important to Emergency Response WM-KW-100 values O/RComments Significance (screening)

Potential Repeat (screening)

Previous Issue CRT Comments 63 No N/A N/A No No Yes CR Search by "Environmental Air' Sampler" identified the followlng:

CR756 - Three REMP Environmental Air Samplers Found Not Running (08/22/2016)

CR746 - Environmental air samplers found not running (08/16/2016)

CR689 - Power found off at K-2 Environmental air sampler (06/28/2016)

CR338 - Hour Meter on Environmental Air Sampler K-41 Was Not Reset (11/17/2015)

CRSB - K-2 Enviromental Air sampler found not working (07/28/2015)

CR547860 - K-31 Environmental Air Sampler lost power (05/06/2014) http://generationdomnet/sites/kpscrs/Lists/CR/DispForm.aspx?ID=784&Source=http%3A...

3/15/2017

l.

CR-K-8 REMP Environmental Air Samplers Found...

Work Order#

Comments Status Content Type: Item Version: 14.0 Created at 9/21/2016 5:20 PM by Darryl M Ho~chbach (Generation - 4) li!1 Last modified at 9/27/2016 4:58 PM by System Account Page 2 of2 As stated, pump was replaced with a rebuilt pump with acceptable carbon vanes and returned to service.

CA(283) to RP (Holschbach/Shannon) to document this event In the 2016 Annual Radlologlcal Environmental Operating Report. Due Date: 05/31/2017 Pending Close http://generationdomnet/sites/kpscrs/Lists/CR/DispForm.aspx?ID=784&Source=http%3A...

3/15/2017