James Davis - Re: Any Correspondence from PNPS on LRA Changes Page I11 From:

James Davis To:

Peter Wen; wilbur jackson Date:

07/24/2006 8:44:18 AM

Subject:

Re: Any Correspondence from PNPS on LRA Changes

Bob, I have not received anything yet. I will pass it on as soon as I do.

Jim

>>> "wilbur jackson" <JacksonWR@msn.com> 07/24/2006 8:40 AM >>>

Jim or Peter --

I believe that the applicant was targeting July 20 as the date from their providing the LRA changes to the NRC.

Has anything been received? Please forward it to me as soon as possible.

Also -- with regard to my questions about the cracking in the jet pump thermal sleeves (recirculation inlet nozzles): The librarian at the public document room did a search for me and we located the PNPS report to the NRC that was requested in the NRC's earlier, related safety evaluation. It is a legacy document, not in ADAMS -- Accession Number 8701150216. Mark Orr got a copy of it, and sent it to me last week. It provided additional information supporting a conclusion that the thermal sleeve cracking was due to IGSCC; so, crack growth would be arrested by PNPS implementation of hydrogen water chemistry. I do not believe there is additional information more recent. than this report, so I do not anticipate asking any additional questions about this.

Best regards, Bob Jackson 615-826-7542 CC:

M Orr

c:\\temp\\GWJ00001.TMP Pae11 c:\\temp\\GWIOOOO1.TMP Page 1 Mail Envelope Properties (44C4COA2.342: 22 : 35346)

Subject:

Creation Date From:

Created By:

Re: Any Correspondence from PNPS on LRA Changes 07/24/2006 8:44:18 AM James Davis JAD @nrc.gov Recipients atlintl.com AM mporr CC (M Orr)

Action Transferred Date & Time 07/24/2006 8:45:17 msn.com AM JacksonWR (wilbur jackson) nrc.gov TWGWPO04.HQGWDOO1 AM PXW (Peter Wen)

AM Transferred 07/24/2006 8:45:17 Delivered 07/24/2006 8:44:28 07/24/2006 8:45:50 Opened Post Office Delivered Route atlintl.com msn.com M

nrc.gov TWGWPO04.HQGWDO01 07/24/2006 8:44:28 A Files MESSAGE Options Auto Delete:

Expiration Date:

Notify Recipients:

Priority:

ReplyRequested:

Return Notification:

Concealed

Subject:

Security:

To Be Delivered:

Status Tracking:

Size 1855 Date & Time 07/24/2006 8:44:18 AM No None Yes Standard No None No Standard Immediate Delivered & Opened