Peripheral Oxide Utility: Comanche Peak 2 Assembly: JW05 Face: 2 Date: 16-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.1 0.1 2.6 -0.5 -0.5 -2.0 -1.6 6.1 0.0 0.6 -0.6 0.4 -1.2 -2.1 7.1 -0.2 1.2 1.2 0.4 -0.4 -1.2 8.1 0.8 2.8 1.1 0.7 -1.1 -2.1 9.1 0.8 1.8 3.8 1.8 0.0 0.0 10.1 0.2 0.4 1.7 1.5 0.3 -0.7 11.1 0.5 1.9 2.5 1.4 3.4 -0.7 12.1 1.3 0.9 2.1 1.4 1.8 0.1 13.1 0.7 1.1 2.9 1.9 1.6 1.2 14.1 2.6 1.6 3.1 1.9 2.1 2.8 15.1 1.9 1.6 3.0 2.4 2.3 2.1 16.1 3.8 1.3 3.7 2.7 1.6 2.0 17.1 2.6 2.8 4.5 2.4 1.4 1.6 18.1 2.4 2.6 4.4 2.5 1.3 0.5 19.1 3.1 3.0 4.2 3.1 1.8 2.2 20.1 2.2 2.7 4.2 2.8 2.9 2.1 21.1 2.4 2.5 3.2 3.0 2.1 2.4 22.1 3.3 3.8 3.6 2.3 3.7 2.2 23.1 2.6 3.2 3.1 2.7 3.2 2.5 29.5 -0.8 1.6 2.0 2.4 1.2 0.8 30.5 -0.4 1.7 2.7 1.2 2.1 1.1 31.5 -0.1 2.3 2.1 1.8 1.4 2.1 32.5 0.0 1.5 1.9 0.4 1.0 2.1 33.5 0.5 2.3 1.8 0.6 1.5 2.4 34.5 0.8 2.6 1.9 0.7 1.7 2.9 35.5 1.8 2.3 1.8 1.0 2.1 1.4 36.5 1.7 3.5 1.9 2.2 1.6 2.2 37.5 2.4 3.7 2.7 2.5 2.8 1.5 38.5 1.8 3.6 2.4 1.7 2.1 2.4 39.5 2.3 4.1 3.9 2.6 3.0 3.1 40.5 2.2 3.2 3.2 1.5 3.1 1.2 41.5 2.6 3.3 4.7 2.3 3.9 2.4 42.5 3.3 3.7 3.7 2.3 3.6 2.4 43.5 2.8 3.7 3.7 2.4 4.1 3.0 50.1 3.6 3.9 3.4 4.2 2.9 1.1 51.1 3.0 5.3 3.6 3.7 1.6 1.5 52.1 3.9 5.2 3.7 3.8 1.5 0.6 53.1 2.9 4.7 3.5 2.4 1.1 0.6 54.1 4.3 3.1 4.2 2.9 1.7 1.2 55.1 4.2 4.7 3.8 3.1 2.8 1.5

56.1 5.6 6.4 4.5 3.1 2.1 2.2 57.1 4.6 6.8 5.2 2.7 4.4 2.0 58.1 4.2 7.5 6.0 3.2 3.7 2.5 59.1 4.8 7.4 7.0 3.0 4.7 3.7 60.1 4.0 7.5 7.2 3.3 4.0 3.8 61.1 3.9 6.1 7.4 4.0 4.3 3.1 62.1 3.7 7.4 8.9 5.7 5.8 3.0 63.1 4.5 5.8 6.9 5.6 4.9 2.9 64.1 5.2 6.8 6.6 6.4 5.8 3.8 70.7 2.3 5.2 5.3 3.9 2.2 3.2 71.7 2.1 4.4 4.4 3.9 3.4 2.4 72.7 1.6 5.4 3.9 3.5 2.4 2.6 73.7 1.8 5.2 4.9 3.6 1.7 2.3 74.7 1.7 6.3 7.2 5.1 2.2 4.4 75.7 2.5 6.9 7.8 4.9 3.0 3.6 76.7 3.6 7.1 7.2 5.1 2.9 5.1 77.7 4.8 7.3 8.4 5.0 4.9 4.6 78.7 4.8 7.9 8.3 5.9 4.0 5.3 79.7 5.1 7.9 9.1 4.5 6.1 5.1 80.7 4.8 6.8 8.1 4.3 5.3 5.8 81.7 5.5 7.5 8.4 4.6 6.5 5.6 82.7 5.2 7.1 8.3 5.8 7.4 6.0 83.7 5.5 8.3 8.4 4.3 6.8 5.9 84.7 4.8 8.1 8.5 5.5 8.7 5.9 91.2 5.2 6.2 7.4 6.6 5.2 4.2 92.2 5.4 5.9 6.5 5.2 3.5 3.6 93.2 6.4 5.7 7.7 5.8 4.8 4.7 94.2 7.2 6.0 6.3 4.7 3.7 4.7 95.2 6.0 5.7 7.0 4.4 4.7 4.7 96.2 7.4 7.3 7.3 5.9 4.8 4.4 97.2 5.8 9.0 8.3 5.9 4.2 4.5 98.2 6.5 8.8 8.6 6.9 5.5 5.0 99.2 5.9 8.3 9.0 7.9 7.0 5.8 100.2 6.0 7.1 9.3 8.8 5.4 6.0 101.2 6.3 9.3 8.9 8.7 6.2 6.2 102.2 6.3 8.0 8.9 8.7 6.8 7.5 103.2 6.1 9.3 9.1 8.4 6.1 6.1 104.2 6.8 10.0 10.3 8.7 6.2 7.2 105.2 6.7 9.5 9.2 7.9 6.6 6.1 111.8 6.5 6.8 6.0 5.6 5.1 4.4 112.8 4.9 6.1 6.0 4.9 5.3 5.0 113.8 6.0 6.6 5.2 6.0 4.9 5.3 114.8 5.5 6.5 5.7 4.1 4.1 5.4 115.8 4.8 7.0 5.1 4.5 5.2 5.2 116.8 4.2 7.3 5.5 4.5 4.2 5.7 117.8 5.0 7.1 6.0 5.9 4.3 5.2 118.8 5.9 7.5 6.0 6.0 6.2 5.7 119.8 5.6 8.0 6.9 7.1 5.7 5.3

120.8 6.1 7.9 6.9 6.8 7.3 5.2 121.8 6.0 8.5 8.2 7.8 6.0 5.8 122.8 6.2 8.2 8.6 7.8 6.3 5.2 123.8 7.2 9.2 8.7 8.9 7.3 5.8 124.8 7.1 8.8 7.7 9.9 7.2 6.3 125.8 6.8 9.2 7.8 8.6 6.8 7.8 132.3 7.4 7.1 8.6 9.1 7.2 6.8 133.3 7.1 7.2 7.3 8.8 6.0 6.0 134.3 7.5 6.9 6.9 8.6 6.2 6.1 135.3 10.2 7.4 6.7 5.9 4.5 5.6 136.3 8.6 6.9 6.1 5.9 4.8 4.3 137.3 7.4 7.1 6.8 7.2 4.9 4.3 138.3 6.4 6.8 8.1 4.9 4.3 3.9 139.3 7.0 7.6 8.9 4.5 4.8 4.4 140.3 8.4 8.6 7.2 4.4 4.3 5.0 141.3 5.9 7.5 6.7 5.3 5.5 4.5 142.3 5.5 9.2 6.6 5.7 5.6 4.7 143.3 4.8 7.3 6.7 5.3 6.5 3.2 144.3 4.6 7.5 6.8 5.6 5.3 4.1 145.3 5.2 6.2 4.5 4.9 2.8 2.0 146.3 3.6 6.1 4.1 5.0 4.0 2.1 max 10.2 10.0 10.3 9.9 8.7 7.8

Peripheral Rod Oxide (Com 50.0 45.0 40.0 Oxide Thickness (microns) 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 0.0 20.0 40.0 60.0 80 Axial Elev FR2 FR6 FR8

xide (Comanche Peak 2, FA JW05, FACE 2) 0 80.0 100.0 120.0 140.0 160.0 Axial Elevation (inch)

R6 FR8 FR10 FR12 FR14