Peripheral Oxide Utility:

Comanche Peak 2 Assembly: HH82 Face:

4 Date:

21-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 90.90 24.47 25.78 25.83 24.49 26.54 27.36 90.94 23.77 27.06 25.82 24.46 25.84 25.92 90.98 24.43 26.37 25.11 24.46 25.89 26.56 91.02 25.07 27.26 25.68 24.49 26.49 26.38 91.06 25.64 26.65 26.48 24.49 25.83 26.37 91.10 23.57 26.68 26.43 24.48 25.90 26.45 91.14 24.24 25.89 25.59 25.23 26.64 25.76 91.18 24.29 26.51 25.67 24.51 27.30 25.75 91.22 24.35 26.53 26.39 23.82 27.29 25.78 91.26 24.32 27.19 25.57 24.32 25.14 25.78 91.30 24.39 27.94 25.69 25.61 26.46 26.42 91.34 25.03 27.88 27.18 24.27 25.71 26.53 91.38 25.05 28.52 25.71 24.94 26.39 25.91 91.42 25.90 27.11 26.39 25.03 27.17 25.89 91.46 29.40 27.09 26.39 25.06 26.44 26.56 91.50 25.28 27.80 25.76 25.72 26.42 27.25 91.54 25.15 29.26 25.66 25.74 27.76 27.25 91.58 25.28 29.29 26.37 25.62 25.75 27.99 91.62 25.20 29.24 26.37 25.00 25.69 27.81 91.66 25.26 30.78 27.10 25.02 27.14 27.83 91.70 25.15 30.11 26.42 25.83 27.91 29.28 91.74 25.14 30.82 27.81 26.52 27.23 29.19 91.78 25.83 30.11 28.54 26.61 27.23 29.19 91.82 26.53 30.19 27.16 25.13 27.95 29.96 91.86 25.74 30.16 27.11 25.84 25.83 30.65 91.90 25.83 30.73 26.44 25.82 27.28 30.01 91.94 25.08 32.19 27.25 25.13 27.30 29.31 91.98 25.80 34.42 26.52 25.14 28.05 30.04 92.02 25.80 32.04 27.87 25.31 27.99 30.80 92.06 25.83 32.87 28.67 25.83 28.71 32.16 92.10 26.52 32.78 28.01 25.89 29.44 30.10 92.14 26.51 32.04 27.84 25.89 29.94 30.82 92.18 27.05 32.81 28.76 25.92 31.39 30.87 92.22 25.71 33.57 27.30 26.62 30.59 31.49 92.26 25.67 34.22 27.99 25.84 30.62 30.68 92.30 26.41 34.20 28.66 25.86 32.06 30.62 92.34 27.07 35.67 30.79 27.17 30.68 30.59 92.38 27.20 34.39 31.54 27.08 30.59 32.08 92.42 27.25 35.24 30.12 27.05 30.67 32.88 92.46 30.19 35.90 29.39 26.40 30.80 33.62 92.50 28.75 34.41 29.48 28.57 30.79 32.81 92.54 29.51 33.70 29.40 27.88 29.99 31.43 92.58 31.59 35.86 29.40 27.89 29.41 32.17 92.62 28.66 37.28 29.48 27.79 29.54 32.20 92.66 29.37 35.67 29.47 27.78 30.02 31.57

92.70 28.59 37.16 30.14 28.50 30.11 31.56 92.74 28.72 36.39 30.82 29.93 30.11 33.01 92.78 29.39 35.70 30.84 29.24 29.44 32.93 92.82 29.30 34.96 31.48 29.94 28.62 32.14 92.86 29.20 35.03 31.54 29.98 28.00 31.54 92.90 28.63 36.27 32.23 30.77 29.42 32.28 92.94 28.50 35.66 32.23 28.59 28.60 32.25 92.98 29.26 35.76 29.98 29.37 27.92 31.54 93.02 30.65 35.77 30.61 29.35 28.52 32.81 93.06 30.63 35.00 31.32 28.64 29.20 32.82 93.10 30.72 34.17 30.57 28.61 28.56 32.76 93.14 31.37 34.94 29.91 28.02 27.79 33.51 93.18 29.97 34.42 29.91 27.91 27.08 33.55 93.22 31.30 34.38 29.93 29.41 27.17 32.83 93.26 31.34 33.77 29.31 29.35 26.31 32.86 93.30 31.44 34.38 30.65 30.09 27.19 32.87 93.34 31.51 34.44 29.99 30.08 26.57 33.57 93.38 30.87 35.98 31.37 29.39 27.96 33.71 93.42 30.82 36.56 31.31 29.48 27.98 33.68 93.46 30.07 35.83 29.98 29.46 27.96 35.11 93.50 30.81 34.37 30.03 30.84 27.90 35.13 93.54 30.14 34.34 31.38 30.88 27.23 34.41 93.58 30.80 35.18 31.52 31.50 28.70 33.73 93.62 30.74 34.34 30.74 32.28 27.98 34.32 93.66 30.73 34.38 31.47 30.03 27.87 34.28 93.70 30.07 33.62 30.85 29.94 28.06 34.97 93.74 29.99 34.38 30.74 30.60 28.74 34.97 93.78 30.08 34.35 30.83 29.92 28.77 35.01 93.82 29.89 34.93 30.84 30.67 28.70 36.39 93.86 29.29 33.51 30.75 30.65 27.89 36.44 93.90 30.63 33.55 30.83 32.05 29.89 34.87 93.94 32.75 33.52 31.53 32.87 29.26 35.11 93.98 34.95 34.26 32.21 32.85 28.59 34.35 94.02 29.91 34.23 32.34 32.10 28.59 35.13 94.06 30.02 34.19 30.91 32.08 28.46 35.77 94.10 29.96 35.75 30.14 32.17 29.92 35.75 94.14 29.96 36.53 30.83 31.49 29.27 36.57 94.18 30.72 33.57 30.91 31.47 29.24 39.50 94.22 30.84 33.03 30.78 31.47 29.94 37.36 94.26 31.63 32.29 30.10 32.88 28.65 37.29 94.30 33.05 32.97 30.73 34.43 29.39 37.35 94.34 32.26 33.71 30.73 34.28 29.40 37.18 94.38 30.75 33.67 30.70 33.67 29.35 37.79 94.42 31.46 33.60 30.68 33.67 29.38 38.60 94.46 31.46 33.65 31.31 33.65 30.09 38.65 94.50 32.84 33.55 30.59 32.99 30.83 38.57 94.54 34.41 33.65 30.68 34.35 30.87 39.24 94.58 33.65 33.53 30.58 34.51 30.91 38.57 94.62 34.24 33.49 32.01 35.15 32.28 38.59 94.66 32.07 33.52 32.08 37.18 31.49 38.56 94.70 32.15 33.58 32.76 36.34 33.47 39.49 94.74 31.99 33.47 34.91 36.43 30.62 38.73

94.78 32.76 34.34 31.43 37.16 30.61 40.20 94.82 32.08 35.19 32.16 37.20 31.41 40.89 94.86 32.78 34.44 33.47 37.12 30.67 41.66 94.90 33.66 35.19 34.25 37.12 33.49 42.41 94.94 33.67 33.74 33.65 38.60 36.42 41.74 94.98 33.00 34.41 32.95 39.31 37.16 41.73 95.02 34.41 35.14 32.92 40.10 33.52 42.26 95.06 37.39 34.37 32.88 40.03 32.82 42.24 95.10 32.25 33.55 32.86 37.99 31.40 42.27 95.14 32.21 34.38 34.39 38.00 30.71 41.49 95.18 33.02 35.83 35.19 39.35 31.53 42.97 95.22 33.68 35.14 33.67 40.16 30.81 46.86 95.26 34.46 34.24 34.35 39.50 31.52 46.72 95.30 34.37 34.92 35.11 38.73 33.73 43.19 95.34 34.25 34.98 35.02 41.74 34.30 42.33 95.38 35.01 34.97 34.40 42.48 33.09 42.41 95.42 33.50 35.02 35.15 41.11 33.01 42.45 95.46 33.58 35.71 33.62 40.29 32.21 43.29 95.50 33.47 36.29 34.43 40.33 33.02 43.24 95.54 33.48 37.12 34.33 40.99 33.77 45.40 95.58 33.48 35.75 34.40 42.28 33.70 46.92 95.62 34.17 36.66 34.39 40.05 33.77 46.01 95.66 34.96 37.30 34.38 40.83 35.03 43.76 95.70 35.14 37.28 35.13 42.24 32.83 43.72 95.74 34.39 37.30 38.77 41.45 32.07 44.52 95.78 32.24 38.11 40.24 40.03 32.10 44.46 95.82 32.28 36.57 37.28 40.73 32.80 44.47 95.86 32.20 38.74 37.34 42.28 32.73 44.45 95.90 32.19 38.73 35.13 42.30 33.52 45.36 95.94 32.23 37.95 35.88 40.75 34.96 46.79 95.98 32.92 38.67 35.94 41.55 33.58 46.11 96.02 33.65 38.58 36.62 40.76 34.38 47.66 96.06 32.07 38.62 38.10 41.49 32.83 46.06 96.10 32.07 37.78 38.77 42.39 33.64 46.22 96.14 31.39 38.62 38.05 40.12 35.83 46.17 96.18 32.06 38.60 36.58 40.16 36.50 46.17 96.22 31.40 40.17 37.27 41.59 34.39 47.68 96.26 30.71 39.23 35.88 42.45 34.39 48.24 96.30 30.54 38.54 35.10 40.94 33.65 49.04 96.34 30.61 39.26 35.76 40.92 33.69 48.31 96.38 32.17 40.22 35.65 41.60 34.49 48.15 96.42 32.33 40.26 34.93 43.90 35.12 47.51 96.46 33.06 39.48 35.62 43.21 35.75 47.58 96.50 31.58 40.90 35.68 41.68 34.96 47.43 96.54 31.59 41.02 35.72 40.97 34.16 47.55 96.58 31.52 42.38 35.01 40.84 34.29 47.57 96.62 32.21 42.48 35.72 40.79 34.17 53.00 96.66 31.58 42.40 36.41 41.47 33.47 52.95 96.70 31.40 40.96 35.70 40.73 34.94 51.42 96.74 32.24 40.21 34.97 40.89 35.65 51.56 96.78 32.87 40.80 34.94 42.20 35.13 51.51 96.82 32.18 41.58 35.02 42.24 34.20 50.62

96.86 32.11 40.71 35.74 40.79 33.57 50.51 96.90 32.20 43.01 34.98 40.83 33.67 49.79 96.94 33.57 44.51 35.65 40.83 34.37 50.54 96.98 33.56 43.00 35.80 41.67 34.40 52.76 97.02 32.09 41.55 35.77 41.65 33.69 53.56 97.06 30.72 42.47 35.80 42.40 35.13 53.51 97.10 31.33 41.72 35.66 43.97 35.89 53.54 97.14 32.05 41.71 36.56 46.91 35.91 51.26 97.18 34.92 42.45 36.52 43.06 34.37 51.39 97.22 36.63 43.15 35.71 42.47 35.04 51.50 97.26 33.68 46.82 35.07 41.62 34.12 50.63 97.30 32.26 46.10 35.77 42.43 35.00 50.69 97.34 32.24 44.55 36.56 43.92 34.92 53.62 97.38 32.19 42.25 35.10 43.96 35.65 53.76 97.42 32.94 41.59 35.12 43.17 37.84 53.01 97.46 31.52 42.31 36.62 45.41 37.88 52.17 97.50 31.36 42.24 36.57 46.20 37.14 52.02 97.54 32.15 42.28 35.72 43.90 37.25 52.01 97.58 32.85 43.06 35.80 42.41 37.37 52.77 97.62 35.64 45.23 36.57 42.30 37.32 51.94 97.66 31.98 45.15 35.84 42.95 37.21 51.97 97.70 31.99 44.46 37.25 42.92 36.44 54.35 97.74 32.15 43.00 37.30 42.24 37.21 56.04 97.78 32.09 43.17 37.32 42.30 40.94 54.47 97.82 32.81 44.01 38.04 44.50 44.62 54.48 97.86 32.31 43.89 38.07 45.17 39.51 53.66 97.90 32.24 43.21 36.67 44.46 39.53 53.58 97.94 32.35 43.94 35.84 42.25 38.01 54.49 97.98 32.28 46.07 36.58 44.53 38.03 54.55 98.02 32.28 46.95 36.63 43.67 37.20 55.39 98.06 32.26 46.77 36.62 42.43 37.01 57.59 98.10 32.87 46.13 37.37 42.41 36.36 58.20 98.14 32.86 45.23 37.26 42.43 37.08 56.60 98.18 32.87 44.54 38.03 44.65 37.05 55.11 98.22 32.17 45.94 37.34 46.07 36.41 55.11 98.26 32.16 47.53 38.04 44.59 36.46 55.12 98.30 33.60 47.50 36.45 43.90 36.48 55.12 98.34 33.53 46.84 35.80 43.95 35.65 55.06 98.38 33.49 46.11 35.82 43.25 36.49 54.38 98.42 32.05 44.57 35.63 43.98 36.58 56.77 98.46 31.31 43.97 36.46 43.95 37.20 57.58 98.50 30.61 43.98 36.37 44.72 37.22 57.64 98.54 32.10 43.94 37.11 46.10 37.22 55.23 98.58 31.27 44.66 36.40 47.60 37.30 54.49 98.62 31.36 45.38 36.33 43.80 36.60 54.49 98.66 32.20 46.15 35.67 43.69 36.67 53.75 98.70 31.36 46.20 36.43 43.79 36.48 54.48 98.74 32.05 45.44 37.13 43.68 36.41 55.89 98.78 32.92 44.68 37.17 42.97 36.48 57.29 98.82 33.01 44.62 37.13 43.10 40.08 55.88 98.86 32.24 44.55 38.50 43.75 40.08 55.11 98.90 32.21 44.54 38.56 45.26 37.12 54.27

98.94 31.50 46.02 37.09 44.55 35.73 54.32 98.98 31.47 46.03 37.19 43.85 35.68 55.03 99.02 32.24 46.00 36.45 42.46 35.66 54.45 99.06 32.17 47.37 36.40 42.36 35.71 53.68 99.10 32.85 46.83 36.56 41.59 36.35 55.95 99.14 32.17 45.48 36.54 41.67 35.73 58.39 99.18 32.27 45.40 37.26 40.97 36.53 56.82 99.22 32.24 46.21 39.48 42.39 37.27 55.38 99.26 31.37 45.33 38.61 43.87 37.32 56.15 99.30 31.34 45.43 37.17 43.87 37.27 57.58 99.34 32.76 45.47 36.54 42.50 37.95 55.29 99.38 32.12 46.10 36.46 41.71 37.28 55.12 99.42 32.84 46.87 36.57 41.70 38.05 55.72 99.46 32.75 46.10 37.29 41.78 38.08 59.73 99.50 32.16 45.40 37.22 41.70 38.09 59.01 99.54 32.07 45.32 37.30 41.59 40.26 55.88 99.58 32.94 44.53 39.48 44.60 38.53 55.08 99.62 32.21 44.67 39.49 45.92 38.54 55.79 99.66 35.12 45.40 38.81 42.13 39.26 54.36 99.70 35.18 45.38 37.29 41.53 40.05 55.20 99.74 35.20 46.14 36.59 40.75 39.46 57.59 99.78 35.06 46.72 36.65 41.45 38.65 56.07 99.82 35.14 45.17 36.62 42.94 38.58 59.16 99.86 35.12 46.01 37.36 42.24 38.53 60.68 99.90 33.59 45.21 38.80 42.30 39.35 56.87 99.94 33.69 44.46 40.32 43.68 39.40 56.87 99.98 33.64 44.45 39.62 42.94 39.50 56.05 100.02 35.79 46.08 38.82 42.26 37.99 55.99 100.06 34.87 47.73 38.08 41.66 38.69 55.79 100.10 35.11 50.73 37.37 43.24 39.40 56.70 100.14 35.07 48.39 37.34 43.17 39.47 57.38 100.18 34.89 46.91 37.24 43.89 39.53 58.91 100.22 34.22 46.16 37.25 43.87 39.49 59.80 100.26 33.47 43.82 39.46 44.61 40.95 57.61 100.30 33.51 44.62 39.46 46.13 40.99 57.58 100.34 34.25 46.01 37.77 46.22 41.01 56.76 100.38 33.62 46.90 37.78 43.96 38.80 57.54 100.42 33.69 48.97 37.78 43.30 38.60 57.67 100.46 33.68 48.34 37.76 42.45 38.54 58.42 100.50 35.12 46.64 38.59 43.02 37.84 58.31 100.54 33.74 46.03 38.54 42.94 37.91 59.90 100.58 33.57 45.11 38.46 42.18 37.83 59.71 100.62 34.40 45.21 40.11 43.05 39.26 59.03 100.66 34.40 46.02 39.30 43.76 38.54 58.94 100.70 34.37 45.30 37.88 42.95 38.57 55.88 100.74 33.69 45.19 38.60 41.66 37.08 56.64 100.78 34.41 46.68 37.82 40.76 37.16 58.38 100.82 35.14 47.71 37.14 41.47 37.24 56.76 100.86 33.56 45.50 37.07 42.31 37.17 56.75 100.90 33.53 45.45 37.11 43.02 36.43 59.02 100.94 33.51 45.39 37.19 42.94 38.73 59.85 100.98 33.49 45.43 37.80 43.85 40.22 58.40

101.02 33.55 43.90 37.12 45.28 38.78 57.65 101.06 33.48 43.83 38.56 43.01 36.65 56.88 101.10 33.51 43.92 38.73 41.72 37.35 56.78 101.14 32.95 46.72 38.69 42.34 37.27 55.92 101.18 33.75 46.75 38.00 42.40 36.31 55.05 101.22 33.70 45.22 39.40 42.42 36.37 55.88 101.26 33.74 43.89 38.72 42.36 35.74 57.41 101.30 35.12 43.74 39.46 42.50 35.68 56.59 101.34 33.03 43.67 40.97 43.15 36.43 55.06 101.38 32.93 43.89 40.20 44.66 35.70 53.60 101.42 32.30 43.94 39.40 42.47 35.67 53.62 101.46 32.24 44.68 38.70 40.95 36.35 54.42 101.50 33.00 46.21 38.80 40.92 36.45 54.48 101.54 32.29 46.09 38.75 40.92 35.83 53.02 101.58 31.49 43.95 38.78 40.06 35.84 53.75 101.62 30.88 43.14 38.04 40.03 35.76 56.01 101.66 31.53 43.10 38.07 40.76 38.73 54.50 101.70 31.57 43.12 38.08 41.50 38.74 53.77 101.74 31.48 43.13 36.60 42.20 35.09 53.00 101.78 31.46 43.07 36.58 40.81 35.14 52.07 101.82 31.41 42.93 35.92 39.34 36.57 51.26 101.86 31.40 46.06 36.62 39.35 35.91 51.20 101.90 31.42 44.54 36.61 40.03 35.89 52.79 101.94 33.50 43.71 35.84 38.68 35.10 52.80 101.98 32.82 43.00 36.44 38.66 36.51 53.58 102.02 32.76 41.56 37.12 38.72 37.08 52.72 102.06 33.51 42.19 36.35 39.50 35.70 51.42 102.10 33.48 41.60 34.94 40.89 34.97 52.14 102.14 33.51 42.42 34.93 40.19 34.95 50.67 102.18 32.84 43.23 34.94 40.18 34.29 49.12 102.22 32.80 45.41 34.97 39.51 34.30 49.12 102.26 33.49 43.96 35.00 39.54 34.25 49.97 102.30 33.60 44.67 34.94 39.53 34.92 51.54 102.34 34.24 43.07 36.40 38.72 39.39 52.27 102.38 34.83 42.42 40.09 39.26 38.70 51.47 102.42 34.94 42.43 35.67 41.55 36.57 50.46 102.46 35.57 42.47 34.98 40.76 36.59 49.68 102.50 35.09 42.27 34.97 40.09 34.35 49.05 102.54 36.67 43.03 34.92 40.72 35.12 48.97 102.58 33.68 43.65 34.93 40.83 35.14 49.04 102.62 33.76 43.80 34.95 40.06 34.49 49.01 102.66 34.35 41.51 35.04 40.70 35.86 52.01 102.70 33.74 41.50 36.37 41.58 36.43 51.40 102.74 33.69 41.45 37.18 40.87 40.03 50.64 102.78 33.67 43.01 34.29 42.45 35.71 49.17 102.82 35.13 43.10 34.94 42.43 35.73 47.60 102.86 33.03 40.97 35.09 42.45 34.20 48.44 102.90 33.59 43.97 35.17 42.40 34.98 48.31 102.94 32.96 44.66 35.81 41.66 34.93 48.48 102.98 33.65 43.16 37.21 42.38 34.98 49.21 103.02 33.56 40.98 37.27 40.96 36.44 52.97 103.06 34.98 41.71 35.05 41.01 41.66 50.48

103.10 35.00 42.42 34.49 40.99 36.50 48.21 103.14 32.80 40.19 34.39 42.38 35.13 45.99 103.18 32.81 40.89 34.29 39.45 33.74 45.92 103.22 31.34 41.60 34.35 40.04 33.71 45.24 103.26 32.75 42.21 34.34 38.45 34.34 45.38 103.30 32.11 42.31 34.39 38.51 33.64 44.37 103.34 32.75 41.55 33.71 38.57 33.65 45.97 103.38 32.82 40.78 33.67 38.65 33.09 47.60 103.42 32.18 39.40 35.13 37.84 35.18 44.68 103.46 37.34 39.30 33.71 38.57 33.68 43.19 103.50 43.24 40.13 33.03 37.79 32.86 42.51 103.54 40.19 41.03 33.03 36.41 33.50 42.53 103.58 30.90 39.54 33.03 35.73 34.95 42.51 103.62 30.01 40.97 33.02 34.97 35.02 42.50 103.66 31.51 39.61 33.75 35.10 34.28 47.61 103.70 31.52 38.81 34.41 35.09 34.96 57.35 103.74 32.24 39.56 33.60 35.81 35.68 51.18 103.78 30.71 40.22 33.57 34.37 34.24 43.87 103.82 31.54 39.47 33.53 35.09 33.44 43.73 103.86 30.73 39.46 33.44 35.10 33.42 41.55 103.90 30.07 40.11 34.15 34.35 32.83 39.33 103.94 29.90 39.47 34.94 34.39 32.88 37.93 103.98 29.10 38.70 32.75 34.38 32.99 38.05 104.02 30.63 38.62 32.09 33.69 32.92 38.00 104.06 30.61 38.68 32.10 32.93 32.14 39.43 104.10 30.60 37.85 31.38 33.76 33.67 39.57 104.14 30.65 37.80 31.31 34.50 32.96 39.46 104.18 30.68 37.83 32.06 35.13 31.50 38.00 104.22 31.42 38.64 32.80 33.70 32.23 38.08 104.26 31.42 38.64 32.84 32.15 33.03 37.32 104.30 32.74 37.87 31.36 32.74 33.65 37.33 104.34 34.94 38.54 31.40 32.82 35.09 36.45 104.38 31.54 39.32 31.29 32.11 32.88 37.80 104.42 31.56 38.85 32.15 32.06 33.41 40.04 104.46 32.39 37.70 32.14 31.32 35.00 37.54 104.50 30.81 38.02 31.40 31.36 34.22 36.39 104.54 32.21 36.65 32.06 32.80 34.17 35.04 104.58 33.65 36.54 31.33 32.82 34.25 34.29 104.62 32.15 36.65 31.41 32.02 32.82 35.04 104.66 31.51 38.01 31.34 31.34 32.77 34.41 104.70 31.46 38.74 31.47 31.38 33.67 33.62 104.74 30.71 37.32 31.47 31.57 32.93 33.66 104.78 31.46 36.58 32.14 32.27 33.58 33.73 104.82 31.54 37.19 31.48 31.53 34.35 33.71 104.86 30.80 37.24 32.21 31.44 32.12 32.97 104.90 30.82 37.22 32.17 32.92 34.37 32.91 104.94 31.28 35.89 32.30 32.94 34.37 32.14 104.98 31.36 35.11 31.53 31.52 33.01 32.02 105.02 31.41 35.11 31.44 31.58 32.96 31.39 105.06 31.38 34.28 32.24 31.54 33.07 32.10 105.10 31.34 34.21 32.18 32.33 32.99 32.77

111.45 27.45 32.63 33.95 34.60 28.24 32.47 111.49 25.30 32.68 34.79 35.41 26.92 33.17 111.53 26.05 33.90 35.50 36.87 27.59 33.84 111.57 26.74 33.17 34.75 37.66 27.61 33.98 111.61 28.27 34.64 35.52 44.32 28.32 34.83 111.65 27.61 35.41 35.55 45.70 28.95 35.49 111.69 26.91 35.35 34.65 38.98 28.85 35.40 111.73 28.29 36.03 37.53 39.66 28.84 36.11 111.77 27.59 36.15 36.81 39.73 28.34 36.76 111.81 26.16 36.95 35.25 41.25 29.01 36.91 111.85 27.00 36.89 37.54 42.74 29.05 36.20 111.89 27.00 35.54 35.41 42.77 28.22 36.26 111.93 27.61 36.20 35.50 41.31 28.93 36.73 111.97 26.73 38.41 35.51 44.34 28.90 36.74 112.01 26.68 40.63 35.48 44.08 28.92 36.73 112.05 26.78 38.19 35.55 41.17 28.92 37.70 112.09 26.77 38.19 38.44 39.68 29.72 39.00 112.13 26.72 39.72 38.45 39.66 29.04 42.11 112.17 26.02 38.26 36.17 40.56 28.09 40.52 112.21 26.83 38.29 35.27 40.57 29.66 38.94 112.25 27.57 38.94 36.08 39.90 29.67 39.00 112.29 26.84 38.34 36.10 41.30 29.76 39.81 112.33 26.86 39.20 36.81 44.18 29.72 39.08 112.37 26.86 40.60 36.77 44.91 29.85 39.19 112.41 26.93 38.44 36.18 41.87 29.64 39.63 112.45 26.29 37.76 36.18 41.86 28.89 39.60 112.49 26.90 38.44 37.63 40.48 29.55 41.36 112.53 27.58 38.39 36.87 40.58 31.09 40.53 112.57 27.37 38.94 36.19 41.34 31.10 39.90 112.61 27.40 38.99 36.26 41.35 31.13 41.29 112.65 27.46 39.64 36.21 42.09 31.23 41.78 112.69 28.17 41.88 36.01 43.45 30.86 41.19 112.73 28.85 43.43 36.08 43.37 31.04 42.04 112.77 28.81 40.48 36.69 42.65 31.04 42.71 112.81 28.15 39.00 38.27 42.64 31.84 44.33 112.85 28.85 39.83 36.73 42.64 32.53 46.54 112.89 29.75 40.57 36.05 42.80 31.82 44.11 112.93 29.01 40.60 36.96 44.31 31.87 43.33 112.97 29.05 39.27 36.98 44.40 31.79 43.35 113.01 29.75 41.44 36.89 47.22 31.71 44.34 113.05 28.31 43.57 36.97 49.38 31.76 44.30 113.09 29.04 44.30 36.88 44.82 31.87 44.35 113.13 28.35 44.04 38.44 43.44 33.35 45.63 113.17 27.68 44.11 39.75 43.48 34.05 47.04 113.21 27.56 41.88 38.18 44.21 34.61 47.88 113.25 27.50 42.71 36.85 43.48 34.49 47.30 113.29 28.15 42.82 37.47 42.88 34.57 47.21 113.33 28.84 44.30 36.77 44.25 33.98 48.02 113.37 28.93 45.05 36.71 46.39 35.36 48.60 113.41 29.54 46.50 39.02 47.94 37.68 47.82 113.45 29.57 43.60 41.34 47.10 35.53 48.65

113.49 29.71 42.76 42.78 47.17 35.22 50.35 113.53 29.74 42.88 39.79 47.30 35.26 52.57 113.57 29.75 42.05 39.19 46.47 37.38 53.30 113.61 30.46 42.59 40.66 46.51 38.37 51.70 113.65 30.36 43.44 39.98 45.91 37.61 50.96 113.69 30.50 44.03 39.01 46.36 37.66 51.81 113.73 31.17 45.66 38.88 48.64 37.61 52.54 113.77 30.51 45.55 39.74 50.10 38.95 54.29 113.81 30.51 44.19 40.45 48.53 37.56 53.93 113.85 30.33 42.74 41.18 48.02 38.22 54.71 113.89 30.96 43.46 40.51 48.80 39.00 59.32 113.93 30.92 43.50 40.52 49.52 41.34 61.87 113.97 31.04 45.10 39.78 49.52 43.62 62.49 114.01 32.43 44.33 40.63 48.02 41.07 59.58 114.05 33.19 44.33 40.54 48.49 40.42 62.46 114.09 38.20 44.83 41.36 50.15 39.67 64.02 114.13 36.95 46.29 42.10 50.87 39.81 65.48 114.17 31.03 45.73 42.67 49.39 39.79 63.32 114.21 31.17 44.77 44.18 49.47 40.58 61.03 114.25 30.39 44.86 44.91 50.23 41.35 62.62 114.29 31.83 45.52 42.69 50.41 42.59 62.43 114.33 31.90 45.80 41.94 50.23 43.31 60.90 114.37 32.68 45.77 42.01 51.59 43.53 57.77 114.41 32.67 46.50 42.81 51.64 41.19 64.94 114.45 32.59 47.28 43.55 53.11 39.77 66.26 114.49 31.86 48.05 43.55 53.99 40.68 67.23 114.53 31.68 48.85 42.81 51.09 41.22 66.31 114.57 32.48 47.31 42.86 50.94 41.18 63.17 114.61 32.45 48.64 43.61 51.02 42.01 63.20 114.65 32.39 47.02 45.02 50.28 44.17 61.88 114.69 32.45 46.36 43.36 50.05 44.37 61.82 114.73 32.55 46.40 43.39 50.04 42.85 61.04 114.77 32.40 47.22 43.37 50.84 42.74 59.98 114.81 34.72 49.47 41.89 52.57 43.33 59.25 114.85 35.43 48.70 42.79 51.01 43.35 58.61 114.89 34.01 48.01 44.25 50.96 43.36 61.03 114.93 33.28 47.21 41.96 51.09 43.51 64.83 114.97 32.62 48.06 41.37 51.84 45.09 62.69 115.01 33.37 47.24 42.87 51.65 49.60 60.84 115.05 34.02 47.35 43.58 51.64 50.93 62.42 115.09 33.41 47.31 42.07 52.36 45.67 63.14 115.13 33.89 49.49 41.20 52.54 44.16 64.11 115.17 33.84 51.58 41.07 54.12 44.24 64.19 115.21 35.32 49.40 41.97 53.31 44.32 63.51 115.25 33.21 48.58 43.38 51.92 44.34 64.72 115.29 33.16 48.58 41.96 52.53 45.00 66.21 115.33 32.44 47.88 40.48 52.29 49.32 64.90 115.37 31.78 48.80 41.33 52.44 50.08 64.13 115.41 31.86 48.69 42.06 51.62 47.84 65.57 115.45 32.56 49.45 42.04 51.62 46.44 69.54 115.49 33.30 53.33 42.04 53.26 46.48 66.13 115.53 32.67 53.33 42.89 54.83 45.78 65.32

115.57 32.59 52.62 44.33 52.60 46.32 66.02 115.61 33.36 51.87 44.89 51.93 46.40 66.37 115.65 34.81 50.99 45.60 51.57 46.29 70.26 115.69 33.31 50.90 46.37 52.44 48.64 68.01 115.73 32.50 50.83 46.40 53.20 53.24 66.18 115.77 32.43 50.97 51.67 53.25 51.90 67.70 115.81 33.83 50.90 54.79 53.39 48.08 69.46 115.85 35.35 53.87 47.98 55.63 46.93 75.96 115.89 32.37 53.24 44.28 57.24 47.12 71.95 115.93 32.46 50.29 44.98 56.47 47.16 70.43 115.97 33.13 51.12 45.02 54.74 47.96 68.44 116.01 33.31 52.66 45.07 53.85 48.85 73.31 116.05 33.27 53.36 44.40 54.74 51.06 72.64 116.09 34.05 54.16 44.25 54.66 56.24 75.14 116.13 34.08 52.57 44.09 53.33 52.47 78.42 116.17 36.15 52.40 44.11 53.25 48.62 76.82 116.21 35.50 55.51 44.83 54.84 47.14 70.86 116.25 34.81 54.69 45.62 57.24 47.26 74.93 116.29 34.75 50.82 47.83 55.52 47.30 75.19 116.33 34.75 51.68 48.70 54.71 48.11 73.48 116.37 34.55 53.24 50.29 54.65 48.50 75.18 116.41 35.39 53.27 48.02 55.45 53.92 75.27 116.45 35.23 53.26 45.73 54.80 52.40 74.86 116.49 36.09 53.39 48.10 54.84 50.99 74.15 116.53 36.82 56.41 48.84 55.65 54.13 71.65 116.57 36.87 58.03 48.76 56.41 59.55 71.95 116.61 36.94 55.65 47.96 56.47 62.41 75.22 116.65 36.95 54.87 50.09 55.50 57.83 78.43 116.69 36.88 54.72 50.09 54.75 49.42 79.82 116.73 36.97 53.97 51.06 54.56 56.35 79.82 116.77 37.01 53.91 52.32 54.62 66.39 73.36 116.81 37.68 55.36 50.23 55.53 65.59 71.90 116.85 38.39 56.26 48.75 55.62 63.30 71.92 116.89 38.93 57.90 48.69 55.66 53.97 71.92 116.93 37.48 58.73 48.75 56.44 55.41 70.98 116.97 38.26 57.32 48.86 56.29 56.47 70.12 117.01 38.19 57.26 49.58 55.46 53.25 71.07 117.05 38.21 56.37 52.61 53.89 51.09 74.22 117.09 38.17 56.45 51.65 54.62 58.02 76.79 117.13 38.95 57.13 51.62 54.83 64.73 74.41 117.17 38.26 56.91 51.75 54.80 63.30 78.91 117.21 38.31 58.62 49.99 54.04 59.21 78.11 117.25 38.37 60.80 49.36 56.37 56.37 75.91 117.29 37.60 58.50 50.26 59.54 55.70 74.27 117.33 37.71 56.20 51.81 57.74 54.13 74.44 117.37 36.91 56.23 52.60 56.20 57.91 77.57 117.41 36.27 56.41 51.75 56.29 52.49 75.73 117.45 36.94 56.35 51.08 56.32 60.06 79.09 117.49 36.26 57.16 51.15 55.56 63.17 79.92 117.53 36.89 57.99 51.07 55.60 60.92 77.63 117.57 37.49 58.80 50.87 55.65 64.11 75.22 117.61 36.70 60.32 50.09 61.07 68.04 73.54

117.65 37.48 58.72 50.10 61.65 69.61 74.93 117.69 36.87 55.50 50.91 58.55 66.16 76.62 117.73 36.73 55.42 51.02 57.04 60.07 79.85 117.77 36.86 55.45 50.31 56.38 60.22 85.02 117.81 38.27 56.13 50.99 56.35 66.32 82.51 117.85 38.37 56.13 51.77 56.39 62.62 79.98 117.89 38.37 57.15 51.78 55.60 61.86 79.06 117.93 37.57 57.92 51.84 55.58 60.81 77.36 117.97 37.64 58.63 51.86 56.30 64.88 75.12 118.01 37.69 57.93 53.39 57.67 70.87 77.52 118.05 37.72 57.25 53.17 57.08 72.73 78.51 118.09 37.73 57.26 52.40 56.35 70.34 76.67 118.13 39.17 55.72 51.62 57.14 67.22 79.84 118.17 38.94 57.12 50.12 57.28 69.47 80.70 118.21 38.88 58.49 50.89 57.21 70.11 78.42 118.25 41.13 57.74 51.73 56.92 70.12 78.43 118.29 40.36 58.57 51.75 57.87 67.85 75.18 118.33 38.18 60.90 51.10 60.07 73.49 75.83 118.37 38.27 59.26 54.10 62.43 78.40 79.84 118.41 37.46 58.59 53.27 58.73 81.67 81.42 118.45 37.47 58.62 52.63 57.16 82.27 79.23 118.49 37.54 59.41 51.87 56.41 79.89 83.26 118.53 37.65 59.48 51.75 56.47 77.48 80.15 118.57 38.36 58.74 51.59 57.80 73.51 75.85 118.61 38.36 60.35 51.67 58.54 70.36 76.62 118.65 38.35 64.97 52.45 57.03 70.37 75.81 118.69 38.49 63.26 53.99 59.26 64.05 75.94 118.73 39.14 60.86 54.74 61.84 64.03 75.97 118.77 39.97 59.32 54.81 61.76 67.75 76.81 118.81 39.12 59.29 53.31 61.79 67.91 79.79 118.85 38.28 58.57 53.37 59.57 63.42 87.34 118.89 38.95 59.26 52.62 58.51 66.38 86.58 118.93 42.67 58.68 52.61 60.89 63.34 80.76 118.97 40.50 59.55 54.84 60.12 60.10 80.05 119.01 38.27 62.55 55.48 59.35 58.61 80.95 119.05 38.94 63.48 54.05 60.97 59.40 78.11 119.09 38.86 61.85 55.39 62.64 60.17 75.82 119.13 39.77 61.85 56.24 62.60 58.75 76.64 119.17 39.94 63.25 56.97 59.54 60.28 80.77 119.21 40.56 63.12 53.35 59.37 60.80 85.82 119.25 41.31 64.05 53.25 59.27 66.23 83.23 119.29 42.88 63.99 54.14 59.34 64.84 79.00 119.33 40.69 63.29 54.05 58.62 61.76 77.44 119.37 39.82 63.94 54.20 59.53 61.03 74.23 119.41 39.75 64.17 56.54 63.42 57.16 74.41 119.45 39.60 63.34 56.42 64.92 60.97 76.77 119.49 39.68 61.80 54.61 63.50 68.62 80.85 119.53 39.67 61.01 53.95 62.54 67.78 80.71 119.57 40.41 60.32 54.69 60.80 67.85 83.15 119.61 42.03 62.70 55.42 60.86 71.19 82.44 119.65 42.70 63.43 55.53 60.07 67.96 80.77 119.69 40.50 65.40 55.52 60.96 69.61 79.23

119.73 40.48 66.15 56.33 61.02 70.16 80.01 119.77 40.59 64.02 58.69 62.53 70.24 79.90 119.81 39.82 63.23 58.69 64.21 77.34 78.26 119.85 40.67 61.70 57.26 63.37 76.64 76.74 119.89 41.33 60.98 55.64 60.87 78.42 78.39 119.93 42.05 60.95 55.51 60.04 78.43 79.34 119.97 42.74 61.82 56.15 60.90 82.55 76.54 120.01 40.40 62.48 55.54 61.01 78.89 75.78 120.05 40.45 63.41 55.46 61.85 75.70 77.24 120.09 40.44 64.97 57.06 62.63 72.54 79.20 120.13 42.59 63.48 59.41 64.24 62.59 78.40 120.17 42.71 61.75 57.08 63.23 59.42 76.83 120.21 41.99 61.64 56.43 62.36 59.54 80.71 120.25 42.07 61.68 56.42 61.63 64.22 85.64 120.29 42.81 64.07 57.19 60.81 64.72 84.11 120.33 43.44 63.24 57.16 60.90 67.01 78.30 120.37 40.53 61.62 57.27 61.07 61.76 80.07 120.41 40.60 62.34 57.14 59.46 54.84 77.67 120.45 41.35 64.21 61.53 60.33 54.12 77.33 120.49 41.38 61.82 61.70 63.39 54.12 76.64 120.53 41.38 61.02 59.26 61.64 54.73 75.82 120.57 41.97 61.90 57.73 60.15 65.47 76.64 120.61 41.89 61.14 57.78 60.09 66.12 77.66 120.65 42.66 61.07 57.06 60.18 65.59 76.62 120.69 42.69 60.92 57.90 58.73 72.70 75.75 120.73 41.89 61.65 57.18 58.62 71.13 76.66 120.77 41.90 67.01 57.92 58.12 67.94 75.07 120.81 41.98 66.96 59.55 57.92 60.83 74.32 120.85 42.62 64.73 61.03 60.01 57.08 73.56 120.89 42.74 63.15 59.46 59.24 53.92 72.60 120.93 42.02 63.36 58.62 57.79 53.27 74.95 120.97 43.51 63.43 57.73 58.66 56.41 76.57 121.01 44.98 62.57 58.48 58.73 61.12 75.10 121.05 43.59 64.19 58.55 59.47 66.18 74.36 121.09 42.86 64.95 58.42 60.32 64.90 76.90 121.13 42.17 70.39 58.66 59.46 63.21 76.62 121.17 42.57 69.65 61.81 59.24 62.57 73.34 121.21 42.77 67.87 64.06 60.92 52.61 74.12 121.25 41.88 63.10 60.96 60.75 53.30 76.00 121.29 42.63 62.45 58.77 58.60 61.06 77.60 121.33 44.06 60.87 58.75 57.90 61.52 75.25 121.37 42.54 62.43 58.02 57.93 61.60 73.36 121.41 41.91 60.87 57.84 58.72 58.66 73.31 121.45 41.11 61.76 57.71 60.26 53.39 73.49 121.49 40.46 63.35 59.34 59.47 53.29 73.58 121.53 40.53 60.94 60.84 59.26 50.36 74.34 121.57 40.63 60.92 60.21 60.85 48.66 77.53 121.61 40.67 60.24 59.40 60.81 48.65 79.78 121.65 41.33 62.68 57.95 58.72 48.67 77.40 121.69 42.13 63.37 59.52 58.72 52.56 75.85 121.73 41.38 62.36 58.74 57.96 68.83 74.34 121.77 40.66 63.20 58.77 58.01 69.62 75.14

121.81 40.63 66.15 62.65 57.83 60.97 77.54 121.85 39.70 66.21 71.17 58.49 49.42 76.54 121.89 39.63 64.02 80.72 60.12 49.39 73.46 121.93 39.71 61.75 72.58 60.85 48.80 72.72 121.97 40.38 61.02 67.84 59.50 48.73 76.78 122.01 41.94 61.07 60.10 59.38 48.73 80.08 122.05 41.94 60.98 58.55 60.21 50.31 77.50 122.09 41.10 61.04 58.56 58.80 53.11 75.05 122.13 40.60 61.80 57.92 58.75 50.81 73.28 122.17 40.54 66.43 58.71 59.24 47.88 73.49 122.21 40.66 65.57 62.58 58.54 47.21 71.97 122.25 41.37 62.34 61.90 60.81 47.27 71.22 122.29 41.33 60.18 58.73 63.35 47.31 72.65 122.33 41.36 60.01 58.03 60.96 47.03 74.99 122.37 42.84 60.06 57.91 59.55 47.09 75.75 122.41 41.42 60.04 56.95 57.97 48.64 73.57 122.45 39.80 60.90 57.80 58.04 51.02 70.29 122.49 39.56 62.62 57.71 57.07 48.84 73.57 122.53 39.74 63.41 60.85 57.04 48.06 73.36 122.57 41.20 63.39 63.31 56.89 47.35 71.60 122.61 41.19 61.90 61.79 59.37 45.66 71.87 122.65 43.35 61.88 59.48 60.26 46.43 71.10 122.69 47.23 61.11 58.68 58.57 47.13 72.80 122.73 43.48 60.94 57.15 58.02 46.40 75.17 122.77 42.77 60.74 56.45 57.20 46.58 73.27 122.81 42.85 60.13 57.14 57.89 47.31 70.08 122.85 39.82 60.09 58.57 59.35 46.30 69.45 122.89 39.10 61.65 60.80 58.51 45.55 70.32 122.93 39.90 61.77 60.87 57.67 44.84 67.94 122.97 39.12 61.01 57.87 62.52 44.25 65.62 123.01 42.79 64.08 56.15 63.45 44.35 64.63 123.05 42.62 63.41 56.32 58.72 44.28 66.20 123.09 40.43 58.73 56.37 57.25 44.10 67.86 123.13 39.72 59.42 57.98 56.39 45.63 67.17 123.17 36.66 58.85 60.41 55.42 45.67 67.13 123.21 36.78 61.09 59.57 55.48 44.30 66.43 123.25 36.76 64.03 58.69 56.25 43.60 66.09 123.29 36.88 60.77 59.30 57.00 42.81 64.08 123.33 37.62 58.45 57.01 59.38 42.85 65.49 123.37 37.65 58.61 55.44 57.91 42.61 71.80 123.41 37.63 58.65 54.67 56.47 41.92 73.59 123.45 37.72 57.89 54.66 57.97 41.92 67.87 123.49 37.65 59.50 54.80 56.13 45.02 67.75 123.53 37.03 60.13 54.07 54.74 45.03 70.18 123.57 37.01 62.65 54.13 54.72 42.13 74.20 123.61 36.91 67.27 57.16 54.80 41.37 71.93 123.65 36.08 67.22 57.13 56.33 40.41 64.12 123.69 35.24 64.88 55.63 59.42 40.48 64.16 123.73 36.76 65.36 53.99 58.75 39.88 72.54 123.77 35.94 60.72 55.33 55.75 39.07 75.80 123.81 34.56 58.57 53.91 53.93 41.37 71.08 123.85 34.57 59.25 52.35 53.14 45.88 66.32

123.89 33.85 59.37 52.49 53.16 42.63 66.43 123.93 33.99 61.06 53.12 53.13 40.48 71.19 123.97 34.74 61.00 55.53 54.10 39.60 75.76 124.01 34.65 57.20 54.06 54.78 39.09 78.18 124.05 35.49 57.99 52.66 57.24 39.23 76.71 124.09 38.41 60.22 51.10 54.89 38.47 75.07 124.13 35.53 58.73 51.01 52.34 38.41 72.82 124.17 34.84 55.66 49.62 51.68 41.06 71.17 124.21 33.27 55.63 49.46 50.86 42.66 72.53 124.25 33.82 56.25 48.56 50.17 40.43 70.95 124.29 34.58 60.11 50.10 50.24 39.08 68.64 124.33 34.63 63.21 50.87 50.29 38.38 65.00 124.37 33.14 62.48 49.27 51.84 37.72 57.93 124.41 33.17 57.80 50.17 53.30 37.45 57.91 124.45 34.65 56.35 48.71 51.06 38.29 58.46 124.49 34.04 55.53 48.04 48.59 38.18 61.65 124.53 32.47 55.57 48.02 48.64 39.77 62.38 124.57 32.58 57.24 48.72 48.72 40.60 57.92 124.61 32.53 57.97 48.82 48.02 39.20 56.43 124.65 32.59 57.18 51.13 47.99 38.29 55.51 124.69 32.62 56.32 51.12 48.05 38.21 54.67 124.73 34.84 54.61 48.69 48.86 36.78 53.94 124.77 35.51 54.73 47.79 51.02 36.96 54.05 124.81 34.03 52.35 47.16 50.84 37.62 54.90 124.85 33.99 52.35 47.02 47.00 36.95 55.69 124.89 32.38 52.54 47.07 46.37 37.68 53.95 124.93 31.67 52.57 48.70 46.34 37.45 51.70 124.97 31.00 56.37 48.78 45.66 36.78 51.67 125.01 30.99 61.11 47.96 45.74 36.84 51.02 125.05 30.95 59.50 47.30 45.09 36.25 50.25 125.09 31.60 52.60 44.31 46.48 36.21 49.66 125.13 32.52 51.87 43.53 47.79 36.99 49.45 125.17 31.88 51.58 43.59 44.14 36.09 53.13 125.21 31.13 52.37 43.54 43.38 35.26 51.59 125.25 30.42 50.91 42.59 42.71 35.96 48.75 125.29 30.43 50.78 41.92 42.80 36.25 47.31 125.33 31.86 52.38 42.52 42.02 35.44 46.64 125.37 31.92 53.19 42.71 42.11 35.53 47.83 125.41 31.20 50.97 41.17 42.06 34.03 46.32 125.45 33.29 50.29 39.80 42.62 33.94 45.63 125.49 30.43 50.21 39.89 42.72 33.84 45.85 125.53 31.62 49.52 39.15 41.12 34.04 47.22 125.57 31.79 48.83 39.15 41.26 33.25 47.31 125.61 31.71 49.56 39.20 41.31 34.05 47.09 125.65 32.39 49.53 39.20 40.64 34.08 47.88 132.00 26.22 37.52 29.04 31.86 31.23 33.84 132.04 25.45 37.43 29.08 31.13 29.61 33.30 132.08 26.89 37.69 29.63 30.46 28.86 34.10 132.12 27.46 38.43 28.21 29.66 31.14 33.78 132.16 27.49 39.12 28.23 30.46 34.81 33.18 132.20 27.58 38.26 29.86 30.26 31.05 33.35

132.24 29.71 39.00 28.85 30.99 28.86 33.36 132.28 26.88 41.37 28.13 30.46 28.95 33.82 132.32 26.01 40.59 28.29 31.20 29.83 33.85 132.36 26.08 39.83 28.30 30.28 28.86 34.00 132.40 26.72 39.78 29.07 30.96 29.66 34.04 132.44 26.91 38.19 27.53 33.33 29.72 33.96 132.48 26.96 38.37 27.46 32.58 29.78 35.32 132.52 26.04 39.20 29.12 30.29 29.51 35.35 132.56 26.69 38.10 30.51 30.29 29.58 35.55 132.60 27.39 38.93 28.28 30.42 29.71 35.33 132.64 27.58 40.51 27.37 31.14 30.43 35.32 132.68 26.22 39.77 27.59 31.00 29.69 36.17 132.72 26.78 40.61 27.61 31.72 29.51 36.11 132.76 26.75 39.70 27.67 31.79 29.65 35.97 132.80 26.02 38.96 27.42 32.52 29.04 36.05 132.84 26.16 40.60 28.22 33.27 28.91 37.60 132.88 26.90 41.21 28.27 33.19 28.83 36.98 132.92 26.82 41.37 27.66 31.86 29.01 37.44 132.96 28.28 41.86 27.54 31.83 29.04 37.52 133.00 25.34 44.12 27.51 31.95 29.81 37.64 133.04 26.93 42.05 28.14 31.74 28.92 37.72 133.08 27.58 39.89 28.32 31.69 29.00 37.64 133.12 27.57 40.60 27.55 33.20 30.42 37.47 133.16 26.77 41.14 28.19 33.40 29.78 38.38 133.20 27.42 41.14 28.14 32.37 29.62 41.31 133.24 29.01 41.22 28.13 32.44 29.71 42.09 133.28 30.41 41.29 28.24 33.28 29.72 37.53 133.32 26.99 42.84 28.38 33.26 29.75 37.59 133.36 28.07 44.03 27.46 32.43 29.65 38.41 133.40 28.12 41.84 28.19 33.22 30.23 39.16 133.44 28.27 40.54 29.02 33.25 30.45 38.33 133.48 29.07 41.37 28.30 34.81 29.83 40.41 133.52 29.07 41.29 28.19 35.25 29.52 46.52 133.56 29.49 41.22 28.23 35.28 29.65 45.04 133.60 30.23 41.20 28.27 34.73 31.84 43.41 133.64 31.81 42.03 28.31 34.08 31.25 39.70 133.68 29.75 44.32 28.32 33.98 30.23 39.78 133.72 29.75 44.37 28.24 34.65 30.23 39.94 133.76 29.63 41.11 28.84 33.94 30.47 39.74 133.80 29.55 40.57 29.00 34.03 30.46 39.81 133.84 30.37 41.31 29.10 34.78 30.23 40.56 133.88 31.11 40.60 29.77 34.57 30.31 45.09 133.92 31.78 40.54 30.95 34.70 31.14 43.41 133.96 31.78 40.43 31.74 34.79 31.95 40.59 134.00 31.03 41.33 28.95 34.79 30.92 40.51 134.04 29.65 42.85 28.38 34.58 30.23 40.63 134.08 29.67 41.30 27.65 35.27 31.15 41.22 134.12 30.47 40.37 28.17 36.15 30.54 41.81 134.16 31.83 38.92 29.57 37.01 30.25 41.28 134.20 31.74 38.96 30.46 38.25 30.95 41.28 134.24 30.31 39.07 31.20 37.48 31.12 41.88 134.28 30.47 39.91 31.10 36.17 30.46 42.77

134.32 30.43 40.44 32.47 36.22 30.93 41.28 134.36 29.72 42.67 31.11 36.28 30.96 40.57 134.40 28.91 43.51 31.21 36.03 30.41 40.41 134.44 29.52 42.88 32.64 36.06 31.20 40.58 134.48 31.15 39.85 31.67 36.12 31.09 41.29 134.52 31.16 38.99 31.73 36.25 30.34 41.27 134.56 33.26 38.20 32.59 38.31 31.11 45.59 134.60 33.84 38.31 31.86 37.40 31.15 48.03 134.64 30.28 38.35 31.07 36.23 31.03 45.77 134.68 29.02 39.14 31.72 36.28 31.65 42.80 134.72 28.98 40.50 32.49 36.77 31.14 42.73 134.76 28.32 41.04 30.35 36.87 31.15 42.78 134.80 28.20 39.07 31.17 36.90 30.50 43.51 134.84 28.18 38.43 29.55 37.63 30.29 43.46 134.88 29.72 37.56 31.01 41.18 30.38 48.58 134.92 31.77 38.23 31.13 39.66 31.15 57.18 134.96 30.44 37.54 30.39 38.31 31.14 53.29 135.00 28.93 37.68 30.48 37.76 30.27 47.01 135.04 28.90 37.68 30.31 36.73 31.02 44.86 135.08 27.37 37.60 31.04 36.72 30.38 44.96 135.12 27.56 38.23 30.35 36.96 31.23 45.81 135.16 27.64 38.27 30.50 36.99 31.09 44.73 135.20 26.75 38.51 30.32 36.93 30.95 44.88 135.24 26.78 37.78 31.00 38.15 30.47 45.73 135.28 26.69 38.19 31.11 41.96 31.22 48.75 135.32 27.61 39.75 30.46 39.81 30.21 49.30 135.36 26.94 38.35 30.38 37.72 31.03 47.19 135.40 27.54 37.63 30.24 36.71 31.11 47.29 135.44 27.47 38.54 31.03 36.80 30.51 47.42 135.48 27.43 38.94 31.20 37.66 30.28 46.40 135.52 27.61 38.25 30.48 37.10 30.99 46.30 135.56 28.31 36.87 30.28 36.76 30.42 48.77 135.60 28.33 36.99 29.62 38.23 31.17 54.13 135.64 29.61 37.02 29.77 39.14 30.34 57.01 135.68 27.53 37.51 29.82 37.68 30.18 53.17 135.72 27.65 36.73 29.75 36.86 31.84 49.44 135.76 28.30 36.93 28.92 36.70 31.93 48.76 135.80 29.05 37.61 29.69 36.89 31.16 47.19 135.84 28.91 37.68 29.66 36.25 30.87 47.26 135.88 28.86 38.21 29.87 36.23 30.31 46.54 135.92 28.33 38.22 30.22 36.71 29.78 48.79 135.96 27.58 36.90 30.27 37.45 29.74 53.97 136.00 28.39 37.71 30.43 36.82 29.54 56.32 136.04 28.11 36.84 31.87 35.50 31.87 54.84 136.08 27.44 36.80 31.11 35.27 34.05 49.57 136.12 28.23 36.82 30.35 36.12 31.91 47.96 136.16 27.61 36.88 29.62 36.28 31.71 47.92 136.20 28.41 36.95 30.37 36.23 31.80 48.03 136.24 28.09 36.09 30.46 36.14 30.52 48.12 136.28 28.11 36.09 30.21 36.78 31.11 48.57 136.32 28.29 36.90 30.32 38.33 30.25 51.73 136.36 28.98 37.56 30.44 38.43 30.32 53.23

136.40 28.38 36.94 31.16 37.01 31.89 52.50 136.44 28.15 36.14 30.46 36.05 31.21 48.66 136.48 28.14 36.05 28.90 35.43 30.31 48.59 136.52 28.93 36.05 29.64 35.53 30.37 47.23 136.56 29.06 35.35 30.45 35.51 30.45 47.31 136.60 28.36 35.51 29.73 33.93 30.54 47.79 136.64 28.10 35.51 30.42 34.60 30.21 47.82 136.68 28.17 35.29 29.64 36.99 30.29 50.29 136.72 27.53 36.82 28.87 36.22 30.38 51.85 136.76 27.54 36.22 28.94 36.00 32.61 50.16 136.80 28.28 36.25 29.78 36.08 31.64 47.88 136.84 28.93 36.08 29.51 35.48 30.27 48.73 136.88 28.90 35.97 29.56 34.83 29.74 46.57 136.92 28.81 35.42 28.94 33.82 30.51 46.31 136.96 28.25 34.82 29.03 33.93 29.55 46.46 137.00 27.67 34.05 28.96 33.98 30.28 46.54 137.04 27.63 33.84 28.90 35.49 30.41 46.53 137.08 26.02 35.31 28.87 35.94 29.73 47.15 137.12 26.74 35.41 28.94 33.16 31.05 46.37 137.16 27.51 35.45 29.08 32.59 30.37 44.30 137.20 29.05 35.53 28.11 32.65 29.69 43.55 137.24 29.83 34.63 28.13 32.49 29.84 42.58 137.28 28.79 35.34 28.29 31.72 28.94 42.78 137.32 27.47 34.01 28.36 32.52 28.81 42.85 137.36 27.65 33.96 29.10 32.62 28.97 42.76 137.40 28.31 33.32 28.22 32.55 29.00 44.91 137.44 26.22 33.85 28.25 31.65 28.29 44.98 137.48 25.30 33.94 28.23 31.84 28.83 42.80 137.52 26.73 32.57 28.39 31.13 28.23 42.86 137.56 27.57 32.61 28.08 31.25 29.04 43.41 137.60 28.95 32.58 28.13 30.92 29.04 42.58 137.64 29.78 33.25 28.30 30.29 28.15 43.65 137.68 28.14 32.47 28.25 30.39 28.20 44.25 137.72 26.74 34.04 29.07 30.43 28.27 46.43 137.76 27.57 33.37 28.17 30.26 27.68 46.46 137.80 28.24 32.57 27.39 29.67 28.18 43.54 137.84 27.68 32.43 27.58 29.61 28.11 40.37 137.88 25.95 32.48 27.58 30.51 28.34 38.93 137.92 25.33 33.19 27.56 30.33 28.39 38.38 137.96 25.43 34.84 27.47 29.63 28.15 38.47 138.00 25.40 35.34 27.43 29.79 28.19 38.19 138.04 25.57 36.03 28.31 30.50 28.29 38.95 138.08 24.69 36.17 27.64 30.86 28.35 40.54 138.12 24.55 35.49 27.37 32.38 28.13 39.87 138.16 24.63 35.53 28.17 33.36 27.48 37.56 138.20 23.39 35.20 27.60 34.73 27.56 35.28 138.24 23.42 36.03 27.59 34.70 27.61 35.41 138.28 23.32 36.91 28.28 34.60 27.58 35.53 138.32 23.15 36.20 27.44 34.69 28.17 33.91 138.36 22.53 36.21 26.82 34.73 27.57 33.82 138.40 22.67 36.79 27.50 34.84 27.58 34.03 138.44 23.43 36.76 27.00 34.66 27.58 33.98

138.48 22.66 35.42 26.69 34.67 26.73 36.91 138.52 22.59 33.96 26.79 34.73 26.78 38.95 138.56 22.49 33.96 26.22 34.82 26.88 40.57 138.60 22.04 33.93 25.46 34.64 26.96 42.10 138.64 22.04 33.95 26.16 30.94 26.06 42.03 138.68 22.03 33.25 25.39 30.50 26.00 42.58 138.72 21.88 33.31 25.38 29.76 25.42 42.74 138.76 21.88 32.57 25.43 29.46 25.53 42.80 138.80 21.99 31.79 24.85 29.63 25.30 42.63 138.84 22.02 31.78 24.68 29.00 25.40 41.90 138.88 22.06 31.96 24.60 28.30 25.38 42.78 138.92 21.84 31.87 24.76 28.21 25.50 42.91 138.96 21.92 33.29 24.05 27.49 25.31 43.31 139.00 21.95 31.67 24.13 27.55 24.79 42.66 139.04 22.05 32.48 23.94 27.59 24.75 39.16 139.08 22.78 31.14 23.98 26.91 24.84 38.59 139.12 22.45 34.82 24.81 26.64 24.63 37.46 139.16 22.55 34.54 24.89 25.39 25.28 37.52 139.20 22.68 31.70 24.54 25.43 25.53 37.74 139.24 22.73 31.76 24.64 25.53 24.79 37.73 139.28 23.45 31.19 24.74 24.67 25.34 37.44 139.32 22.44 30.47 24.09 24.53 25.36 36.72 139.36 22.51 30.91 24.17 25.37 26.12 37.69 139.40 22.71 30.93 23.94 24.90 24.80 37.68 139.44 21.99 31.05 23.32 24.74 25.36 38.17 139.48 22.06 30.45 23.36 23.95 24.72 37.46 139.52 22.55 29.77 24.15 24.06 24.69 35.42 139.56 22.51 29.58 23.23 24.81 24.78 32.00 139.60 21.89 30.27 23.20 24.68 24.60 31.68 139.64 21.96 31.21 24.04 23.90 24.62 31.71 139.68 21.36 30.43 23.45 24.06 25.39 31.90 139.72 21.86 31.05 24.08 24.05 24.80 32.65 139.76 21.86 30.33 23.91 23.39 24.61 33.07 139.80 22.68 29.57 23.28 23.24 24.70 31.74 139.84 22.68 29.62 23.30 23.32 24.79 32.48 139.88 21.97 29.81 23.44 23.33 24.81 32.68 139.92 22.53 28.89 23.33 23.43 24.60 31.65 139.96 21.92 29.61 23.27 22.60 23.90 31.69 140.00 21.95 29.65 23.32 22.59 24.05 31.13 140.04 21.26 30.38 24.09 22.66 24.10 29.86 140.08 22.07 29.06 22.77 23.46 24.62 28.09 140.12 21.86 28.83 23.27 22.53 23.92 28.25 140.16 21.86 28.14 23.27 22.53 24.74 28.31 140.20 22.01 28.27 23.35 22.73 24.10 28.41 140.24 22.03 28.98 23.40 22.71 24.82 28.27 140.28 21.39 28.42 23.42 21.88 23.81 28.24 140.32 21.07 28.12 23.28 22.52 24.79 28.33 140.36 21.84 27.44 23.19 21.93 24.73 27.68 140.40 21.30 27.56 23.32 22.02 24.78 27.49 140.44 21.28 27.65 23.46 21.93 24.00 27.58 140.48 21.30 26.86 22.48 21.07 23.34 27.63 140.52 21.07 26.79 23.31 21.90 24.06 26.90

140.56 21.14 26.80 23.33 21.29 23.46 25.35 140.60 21.29 26.88 23.37 21.36 23.29 25.38 140.64 20.57 26.25 24.15 21.76 23.91 26.91 140.68 21.33 26.78 23.20 21.08 23.35 26.79 140.72 21.81 26.03 23.20 21.38 23.42 26.70 140.76 21.16 25.99 23.43 21.35 23.25 26.13 140.80 21.26 26.22 23.40 21.14 23.23 25.53 140.84 21.26 26.39 23.92 21.27 23.30 25.28 140.88 21.41 26.05 23.18 21.96 23.41 24.68 140.92 20.46 25.35 23.25 21.39 23.28 24.68 140.96 20.45 25.49 23.37 21.15 23.90 24.84 141.00 20.53 25.48 24.16 21.13 23.39 24.63 141.04 20.59 24.85 22.56 21.23 23.46 23.89 141.08 21.38 24.55 21.91 21.35 23.23 24.03 141.12 21.16 24.62 22.71 21.08 23.39 24.13 141.16 21.13 24.85 22.76 20.49 23.43 23.95 141.20 20.57 24.77 22.62 20.54 23.44 24.76 141.24 20.54 24.13 21.81 20.61 23.27 23.97 141.28 20.67 23.94 22.53 20.45 22.60 24.13 141.32 20.38 25.31 22.61 21.13 23.30 24.58 141.36 20.44 25.47 22.71 21.29 23.41 23.27 141.40 20.60 24.16 22.53 20.70 23.19 24.07 141.44 19.93 24.69 22.56 20.40 23.34 24.18 141.48 20.65 23.88 22.71 20.46 23.44 24.74 141.52 19.82 23.98 22.73 20.51 23.41 23.95 141.56 19.82 23.34 22.61 21.34 23.27 24.78 141.60 20.59 23.47 23.29 21.27 23.37 24.81 141.64 19.91 22.54 22.65 20.42 23.44 23.97 141.68 19.19 22.57 22.64 20.60 23.49 25.37 141.72 19.15 22.64 22.08 20.62 23.17 25.43 141.76 19.83 22.73 21.77 20.58 24.00 24.12 141.80 19.25 22.66 21.86 21.15 23.32 24.58 141.84 19.25 22.54 22.04 21.24 23.39 24.62 141.88 19.23 22.51 22.69 21.31 23.21 23.40 141.92 19.10 23.33 22.73 21.37 22.47 24.08 141.96 19.15 23.44 23.21 20.37 23.34 25.37 142.00 19.89 21.81 23.18 20.48 22.80 25.46 142.04 19.91 22.53 22.65 20.59 22.43 26.92 142.08 19.25 23.43 22.79 20.60 22.51 25.32 142.12 18.46 22.02 22.47 20.45 22.02 25.32 142.16 18.42 22.76 22.60 20.47 22.04 25.43 142.20 18.45 21.83 22.66 20.61 22.49 26.16 142.24 18.54 21.89 22.68 20.00 21.87 26.19 142.28 19.25 21.21 22.68 19.74 21.91 26.06 142.32 18.39 21.35 22.55 19.68 22.00 25.43 142.36 18.41 21.83 22.58 19.89 22.61 27.60 142.40 18.63 21.82 23.41 19.87 22.62 29.00 142.44 18.60 21.88 23.43 19.86 22.67 26.01 142.48 19.24 23.34 23.22 19.81 22.01 26.83 142.52 19.18 23.40 23.22 19.10 21.90 26.18 142.56 19.06 22.52 23.33 19.21 21.87 26.18 142.60 18.53 22.57 23.41 19.29 21.92 26.77

142.64 18.59 23.39 22.73 19.10 22.04 26.12 142.68 18.55 22.78 23.31 19.23 21.23 26.21 142.72 19.12 22.65 23.24 19.24 21.12 26.27 142.76 19.08 21.86 22.65 19.33 21.42 25.44 142.80 19.26 22.53 22.77 19.13 21.30 26.01 142.84 19.21 23.41 22.55 19.13 22.01 26.89 142.88 19.26 21.96 23.17 19.27 21.80 26.88 142.92 19.79 22.52 22.61 19.95 22.62 25.43 142.96 21.82 21.78 22.62 19.70 22.69 26.10 143.00 19.90 21.99 22.80 19.12 22.73 26.84 143.04 19.92 22.62 22.48 19.16 21.86 26.10 143.08 19.98 22.03 22.57 18.60 21.92 26.05 143.12 19.03 21.12 22.04 18.32 21.92 26.83 143.16 19.77 21.16 22.03 18.45 21.97 26.83 143.20 19.86 21.31 21.94 19.23 21.16 26.77 143.24 20.59 22.64 21.23 19.29 21.21 28.21 143.28 22.06 21.34 22.00 19.02 21.33 25.50 143.32 20.42 20.53 22.04 18.34 22.02 24.75 143.36 19.73 21.83 21.33 18.57 21.86 24.82 143.40 19.99 21.26 21.04 18.60 21.21 24.57 143.44 19.95 20.66 21.18 18.32 22.00 24.00 143.48 19.98 21.27 21.25 18.40 22.02 24.08 143.52 19.75 21.11 21.28 18.53 21.10 23.29 143.56 19.78 20.52 21.30 18.64 21.89 23.23 143.60 19.86 20.49 21.90 18.41 21.95 22.65 143.64 19.92 21.33 22.51 18.41 22.77 22.00 143.68 19.97 21.78 21.93 18.56 21.86 21.89 143.72 20.51 21.86 21.99 19.25 21.15 21.87 143.76 20.48 22.70 21.20 18.58 21.31 21.93 143.80 19.93 21.35 21.15 18.40 21.30 21.30 143.84 19.92 21.97 22.00 18.37 21.17 21.09 143.88 20.68 21.11 22.73 19.96 21.13 21.90 143.92 21.20 22.51 22.65 20.60 21.33 20.56 143.96 19.10 22.06 23.93 19.78 21.34 21.29 144.00 19.84 21.34 24.80 19.87 20.49 21.82 144.04 19.89 21.25 24.08 20.59 21.21 20.44 144.08 19.25 21.90 25.55 22.05 20.54 20.51 144.12 19.08 22.54 23.24 21.09 21.31 19.92 144.16 19.09 22.60 23.31 21.22 21.37 20.43 144.20 18.46 20.68 24.10 22.04 21.14 19.78 144.24 18.55 21.03 24.82 21.35 20.47 19.20 144.28 17.91 20.46 23.23 21.23 20.55 19.21 144.32 17.74 20.47 22.61 21.20 19.98 19.12 144.36 17.63 22.00 22.70 21.36 19.79 19.06 144.40 18.37 20.67 21.99 21.46 19.83 19.21 144.44 18.50 20.45 21.97 21.08 19.92 18.51 144.48 17.92 20.46 21.11 22.58 19.96 18.32 144.52 19.11 20.54 21.18 22.02 19.79 19.82 144.56 18.46 19.92 20.57 20.69 19.76 18.57 144.60 17.12 20.72 19.93 20.41 19.18 17.88 144.64 17.15 20.47 20.41 19.71 20.00 18.37 144.68 17.93 19.75 19.06 19.91 19.70 18.42

144.72 18.45 19.89 19.89 19.95 19.84 17.83 144.76 17.11 19.99 19.26 19.11 19.79 17.89 144.80 16.33 19.78 18.46 19.05 20.00 17.66 144.84 17.13 19.81 19.82 19.93 19.67 17.08 144.88 16.52 20.55 18.45 19.95 19.00 17.83 144.92 17.06 19.95 18.57 18.45 19.20 17.95 144.96 16.39 20.03 19.27 19.15 19.31 17.74 145.00 16.48 19.74 17.66 19.21 19.00 18.40 145.04 16.54 19.78 17.64 19.26 19.13 17.90 145.08 16.50 19.27 17.90 18.63 19.10 17.93 145.12 16.39 18.57 17.90 19.15 19.29 17.77 145.16 16.39 18.50 18.56 18.48 19.11 17.06 145.20 16.44 19.05 17.68 17.94 19.01 17.19 145.24 16.47 19.87 17.75 17.87 19.24 17.86 145.28 16.57 19.82 18.49 17.79 19.28 19.02 145.32 16.51 19.27 18.55 17.12 19.18 17.88 145.36 16.42 19.71 16.93 17.13 19.85 17.88 145.40 16.28 18.33 17.71 17.95 19.25 17.86 145.44 16.47 19.96 17.86 16.97 19.25 16.33 145.48 16.58 19.23 17.16 17.09 19.09 16.50 145.52 16.53 18.58 17.22 17.13 19.16 16.50 145.56 17.07 17.67 17.12 17.93 19.25 16.41 145.60 17.18 19.05 17.02 16.33 18.57 16.30 145.64 16.43 18.48 17.22 15.65 18.43 16.45 145.68 16.53 17.88 17.18 15.82 19.06 16.53 145.72 16.43 18.59 16.98 16.48 19.20 17.29 145.76 16.42 17.74 16.34 16.39 18.60 16.39 145.80 16.30 17.71 16.52 16.34 19.72 15.82 145.84 16.54 17.14 17.28 16.51 19.09 15.89 145.88 15.82 17.87 17.15 15.82 18.53 16.37 145.92 16.43 19.20 17.10 15.87 18.58 16.30 145.96 16.31 18.43 17.09 16.40 18.37 15.79 146.00 16.42 17.78 17.14 15.74 18.40 15.82 146.04 15.68 18.51 17.25 16.46 18.46 15.78 146.08 16.61 17.22 17.00 16.53 18.59 15.64 146.12 15.81 17.07 17.06 15.68 18.38 15.85 146.16 16.36 16.98 17.87 15.75 17.77 15.82 146.20 15.83 17.80 18.55 15.75 18.58 16.53