Peripheral Oxide Utility:

Comanche Peak 2 Assembly: JJ83 Face:

1 Date:

15-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 6.2 8.2 9.0 7.8 7.9 7.2 5.7 7.2 8.4 9.0 8.2 7.5 6.6 7.0 8.2 9.7 7.6 9.3 7.4 7.4 8.7 9.2 9.1 8.1 8.0 7.2 7.9 8.7 10.2 8.9 10.1 9.0 8.0 9.1 8.7 11.2 8.8 11.9 10.3 7.9 8.5 9.1 12.2 10.1 10.0 10.6 7.3 8.7 8.5 13.2 10.1 10.8 14.3 7.5 9.2 9.6 14.2 10.0 10.3 10.3 7.7 9.6 10.4 15.2 11.7 11.0 10.7 8.7 9.5 9.2 16.2 10.9 10.6 10.9 9.2 9.5 9.1 17.2 10.3 9.1 11.4 9.3 9.6 8.2 18.2 10.5 10.8 12.8 8.6 10.5 9.6 19.2 10.5 12.0 10.7 8.9 9.5 9.7 20.2 13.4 11.9 12.8 11.1 9.2 8.8 21.2 11.0 11.0 11.6 11.7 9.8 9.3 22.2 11.0 10.1 12.2 10.9 10.0 10.0 23.2 10.7 10.3 10.8 9.2 10.0 11.0 29.7 8.9 10.6 12.2 10.1 7.7 9.7 30.7 10.8 12.8 12.4 9.2 7.3 8.1 31.7 11.7 10.4 10.9 7.9 7.3 8.5 32.7 11.1 12.7 11.4 6.9 7.6 9.7 33.7 9.5 12.0 11.7 7.8 7.9 10.1 34.7 10.6 12.7 11.4 8.3 8.8 9.8 35.7 12.1 10.7 12.7 8.5 8.6 9.1 36.7 11.0 11.4 12.2 7.9 9.0 9.1 37.7 12.2 10.7 13.5 8.5 9.3 9.9 38.7 12.1 12.2 13.0 9.3 9.2 10.0 39.7 12.4 13.0 13.3 10.4 9.2 8.5 40.7 12.6 12.2 13.4 10.1 9.6 8.2 41.7 11.2 12.5 12.4 9.3 10.1 9.1 42.7 11.8 11.7 14.7 10.0 11.1 10.2 43.7 12.0 11.9 13.3 10.4 10.0 9.2 50.3 11.2 12.2 12.2 11.7 9.8 9.0 51.3 11.5 11.0 11.8 10.5 9.3 9.7 52.3 12.7 12.5 10.7 9.8 8.7 10.1 53.3 11.8 13.0 10.6 10.1 9.2 10.5 54.3 11.9 13.1 10.3 10.6 9.2 9.6 55.3 12.0 13.3 11.1 10.5 9.1 9.5 56.3 12.1 12.9 11.3 10.5 8.7 10.9 57.3 12.0 14.2 11.0 10.4 9.1 12.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 Oxide Thickness (microns)

58.3 11.3 16.9 11.1 12.0 10.2 12.3 59.3 11.4 14.6 11.3 13.2 10.7 11.1 60.3 12.7 14.0 12.7 13.1 11.0 11.2 61.3 13.5 14.2 13.1 12.4 11.5 12.0 62.3 11.6 14.4 12.7 12.3 11.7 12.1 63.3 12.4 15.5 13.1 13.8 11.6 12.2 64.3 13.2 15.1 13.2 13.4 11.4 11.8 70.8 10.5 13.2 13.5 10.9 9.9 9.6 71.8 11.7 11.6 12.2 9.9 9.5 10.2 72.8 12.1 12.1 12.1 10.2 9.3 10.1 73.8 12.1 12.8 12.1 10.9 10.7 9.9 74.8 12.6 12.8 12.1 10.9 10.1 9.8 75.8 14.0 12.8 14.3 9.9 10.5 11.5 76.8 14.4 13.7 14.6 9.5 10.8 11.6 77.8 14.0 14.6 13.9 10.4 11.9 11.7 78.8 13.5 14.6 15.2 12.4 11.6 11.2 79.8 13.0 14.0 13.7 11.7 11.4 10.6 80.8 14.2 14.5 13.9 11.9 12.3 10.7 81.8 14.3 14.8 13.3 11.8 13.3 11.4 82.8 13.3 15.2 13.1 12.6 13.1 11.6 83.8 12.5 15.4 13.8 13.9 12.9 11.4 84.8 13.1 14.6 13.7 13.4 12.2 11.2 91.4 11.6 15.8 12.2 11.7 10.7 11.3 92.4 10.9 16.5 12.2 11.7 10.7 10.7 93.4 11.8 15.8 11.4 12.3 11.0 10.0 94.4 12.4 15.4 11.3 13.1 11.0 9.3 95.4 11.8 15.3 10.7 13.4 11.6 10.3 96.4 12.6 15.9 11.6 13.1 12.2 12.2 97.4 12.9 17.1 12.0 13.6 12.6 11.7 98.4 12.9 17.0 12.4 14.8 13.2 11.9 99.4 12.9 18.1 12.7 15.3 13.1 11.0 100.4 12.6 17.3 12.7 15.0 13.6 11.7 101.4 13.6 17.5 13.8 14.4 14.3 12.1 102.4 14.6 17.4 13.5 14.7 13.8 12.5 103.4 15.2 17.1 14.0 15.1 13.6 12.3 104.4 15.8 16.7 13.1 15.6 14.3 11.9 105.4 13.7 16.2 13.4 15.4 15.3 12.8 111.9 13.2 13.9 13.8 12.0 11.2 11.5 112.9 12.8 13.5 14.8 12.4 12.4 11.4 113.9 13.0 13.1 13.8 13.0 13.0 10.8 114.9 13.2 13.4 13.3 12.5 12.0 11.6 115.9 13.6 15.6 14.9 11.5 12.6 11.9 116.9 13.3 16.0 14.3 12.0 12.7 11.9 117.9 13.8 15.3 15.5 13.9 13.1 11.5 118.9 14.8 15.0 14.8 14.1 12.5 11.5 119.9 13.9 16.0 14.1 14.1 13.2 12.1 120.9 13.7 17.6 15.3 13.6 14.4 12.8 121.9 14.1 17.1 14.7 13.8 13.7 12.7 122.9 15.2 16.2 14.8 14.9 13.3 12.6

123.9 14.5 15.6 16.0 15.4 13.1 13.0 124.9 13.7 15.5 14.4 15.1 13.7 13.2 125.9 13.5 16.0 14.1 14.5 14.0 13.8 132.5 13.2 13.5 12.3 12.6 11.5 9.5 133.5 11.6 11.6 12.6 12.9 11.2 9.9 134.5 12.0 11.7 11.8 12.7 11.0 10.5 135.5 13.2 12.0 10.8 12.3 10.7 11.1 136.5 12.5 12.2 11.7 12.3 11.0 10.3 137.5 11.2 12.3 11.0 11.8 10.6 9.7 138.5 11.0 11.6 9.6 12.3 10.6 9.2 139.5 11.4 11.7 9.8 11.0 10.1 9.2 140.5 11.2 13.4 10.2 10.7 9.3 9.7 141.5 10.0 13.7 9.9 10.2 9.6 9.6 142.5 10.8 11.9 10.4 10.2 9.5 9.2 143.5 11.2 11.1 10.1 10.7 9.8 9.7 144.5 10.4 11.0 9.9 10.1 9.9 10.0 145.5 9.7 11.0 9.8 9.1 10.3 10.3 146.5 9.6 11.0 9.2 9.0 9.7 10.4 max 15.8 18.1 16.0 15.6 15.3 13.8

Peripheral Rod Oxide (Comanche Peak 2, FA JJ83, FACE 1) 20.0 40.0 60.0 80.0 100.0 120.0 14 Axial Elevation (inch)

FR2 FR6 FR8 FR10 FR12 FR14

140.0 160.0