Report 06-0413 Chart 250-200
ML070230396
Person / Time
Site: Comanche Peak  
Issue date: 04/10/2006
From:
Keeler & Long PPG
To:
Office of Nuclear Reactor Regulation
References
06-0413
Download: ML070230396 (7)


Text

Start = Monday, April 10, 2006 12:45:27 PM:000 Span = 0 Day(s) 0 Hour(s) 26 Min(s) 3 Sec(s)

This data has been sampled using a user defined sample period.

Blank cells are padded with the previous data value.

Recorder Name(s)

Recorder Recorder Recorder ID 1

1 1

Serial No.

523359 523359 523359 Scale and Units 0 - 175PSI 0 - 500°F 0 - 500°F Pen No.

3 2

1 Pen Name PRESSURE LOWER AUTO UPPER AUTO Date and Time Sample Sample Sample Monday, April 10, 2006 12:45:32 PM:000 30.1 252.8 252 Monday, April 10, 2006 12:45:37 PM:000 30.1 252.8 251.9 Monday, April 10, 2006 12:45:42 PM:000 30.2 252.8 251.9 Monday, April 10, 2006 12:45:47 PM:000 30.3 252.8 251.9 Monday, April 10, 2006 12:45:52 PM:000 30.2 252.8 251.9 Monday, April 10, 2006 12:45:57 PM:000 30.2 252.8 251.9 Monday, April 10, 2006 12:46:02 PM:000 30.1 252.9 251.9 Monday, April 10, 2006 12:46:07 PM:000 30.2 252.9 251.9 Monday, April 10, 2006 12:46:12 PM:000 30.2 252.9 251.9 Monday, April 10, 2006 12:46:17 PM:000 30.2 252.9 251.9 Monday, April 10, 2006 12:46:22 PM:000 30.2 252.9 251.9 Monday, April 10, 2006 12:46:27 PM:000 30.2 252.9 251.8 Monday, April 10, 2006 12:46:32 PM:000 30.2 252.9 251.9 Monday, April 10, 2006 12:46:37 PM:000 30 252.9 251.9 Monday, April 10, 2006 12:46:42 PM:000 30.1 252.9 251.9 Monday, April 10, 2006 12:46:47 PM:000 30.2 252.8 251.9 Monday, April 10, 2006 12:46:52 PM:000 30.2 252.9 251.9 Monday, April 10, 2006 12:46:57 PM:000 30.3 252.9 251.9 Monday, April 10, 2006 12:47:02 PM:000 30.2 252.9 251.8 Monday, April 10, 2006 12:47:07 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:12 PM:000 30.1 252.9 251.8 Monday, April 10, 2006 12:47:17 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:22 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:27 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:32 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:37 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:42 PM:000 30.3 252.9 251.8 Monday, April 10, 2006 12:47:47 PM:000 30.3 252.9 251.7 Monday, April 10, 2006 12:47:52 PM:000 30.3 252.9 251.7 Monday, April 10, 2006 12:47:57 PM:000 30.3 252.9 251.7 Monday, April 10, 2006 12:48:02 PM:000 30.3 252.9 251.7 Monday, April 10, 2006 12:48:07 PM:000 30.3 252.8 251.7 Monday, April 10, 2006 12:48:12 PM:000 26.9 252.8 243.7 Monday, April 10, 2006 12:48:17 PM:000 18.9 252.9 226.9 Monday, April 10, 2006 12:48:22 PM:000 16.7 252.9 217.1 Monday, April 10, 2006 12:48:27 PM:000 16.2 248.9 213.6 Monday, April 10, 2006 12:48:32 PM:000 16 247.7 210.8 Monday, April 10, 2006 12:48:37 PM:000 15.6 247.7 216.9 Monday, April 10, 2006 12:48:42 PM:000 14.7 246.3 215.2 Monday, April 10, 2006 12:48:47 PM:000 14 245.9 210.8 Report 06-0413 Chart 250-200 1 of 7

Monday, April 10, 2006 12:48:52 PM:000 13.6 244.3 209.6 Monday, April 10, 2006 12:48:57 PM:000 13.3 243.2 209 Monday, April 10, 2006 12:49:02 PM:000 13.1 242.9 201 Monday, April 10, 2006 12:49:07 PM:000 12.7 241.5 200.2 Monday, April 10, 2006 12:49:12 PM:000 12.6 241.7 198.4 Monday, April 10, 2006 12:49:17 PM:000 12.8 241.6 200.2 Monday, April 10, 2006 12:49:22 PM:000 13.3 241.7 209.8 Monday, April 10, 2006 12:49:27 PM:000 13 241.8 200.9 Monday, April 10, 2006 12:49:32 PM:000 13 240.4 202.6 Monday, April 10, 2006 12:49:37 PM:000 13 239.3 204.7 Monday, April 10, 2006 12:49:42 PM:000 12.7 238.2 206.7 Monday, April 10, 2006 12:49:47 PM:000 12.3 237.5 201.3 Monday, April 10, 2006 12:49:52 PM:000 11.6 237.5 200.6 Monday, April 10, 2006 12:49:57 PM:000 10.9 237 200.5 Monday, April 10, 2006 12:50:02 PM:000 10.8 236.3 199.1 Monday, April 10, 2006 12:50:07 PM:000 10.6 236.4 198.8 Monday, April 10, 2006 12:50:12 PM:000 10.5 236.5 201 Monday, April 10, 2006 12:50:17 PM:000 10.4 236.5 202.9 Monday, April 10, 2006 12:50:22 PM:000 10.2 236.1 202.8 Monday, April 10, 2006 12:50:27 PM:000 10 235.3 200.8 Monday, April 10, 2006 12:50:32 PM:000 9.6 235.1 202.5 Monday, April 10, 2006 12:50:37 PM:000 9.9 235 202.5 Monday, April 10, 2006 12:50:42 PM:000 9.8 234.9 203.8 Monday, April 10, 2006 12:50:47 PM:000 9.9 234.6 211.9 Monday, April 10, 2006 12:50:52 PM:000 9.6 234.2 202.2 Monday, April 10, 2006 12:50:57 PM:000 9.6 233.8 203.8 Monday, April 10, 2006 12:51:02 PM:000 9.5 233.5 199.9 Monday, April 10, 2006 12:51:07 PM:000 9.7 231.9 203.7 Monday, April 10, 2006 12:51:12 PM:000 9.8 232.2 202.4 Monday, April 10, 2006 12:51:17 PM:000 9.9 231.3 205.1 Monday, April 10, 2006 12:51:22 PM:000 9.8 231.3 199.4 Monday, April 10, 2006 12:51:27 PM:000 9.8 231.8 197.1 Monday, April 10, 2006 12:51:32 PM:000 10 231.3 195.4 Monday, April 10, 2006 12:51:37 PM:000 10.2 230.7 207.1 Monday, April 10, 2006 12:51:42 PM:000 9.7 230.7 197.3 Monday, April 10, 2006 12:51:47 PM:000 9.7 230.5 200.4 Monday, April 10, 2006 12:51:52 PM:000 9.7 230.2 199.1 Monday, April 10, 2006 12:51:57 PM:000 9.6 229.8 196.1 Monday, April 10, 2006 12:52:02 PM:000 9.6 229.2 196.5 Monday, April 10, 2006 12:52:07 PM:000 9.5 229 192.7 Monday, April 10, 2006 12:52:12 PM:000 9.8 228.2 191.5 Monday, April 10, 2006 12:52:17 PM:000 10.9 227.8 204.6 Monday, April 10, 2006 12:52:22 PM:000 10.5 227.6 200.9 Monday, April 10, 2006 12:52:27 PM:000 10.6 227.1 203 Monday, April 10, 2006 12:52:32 PM:000 10.4 226.5 200.7 Monday, April 10, 2006 12:52:37 PM:000 10.3 226.2 203.1 Monday, April 10, 2006 12:52:42 PM:000 10.1 226.1 204.5 Monday, April 10, 2006 12:52:47 PM:000 10 225.7 200.4 Monday, April 10, 2006 12:52:52 PM:000 10 225.3 204.2 Monday, April 10, 2006 12:52:57 PM:000 10.2 225.3 203.2 Monday, April 10, 2006 12:53:02 PM:000 10.1 225.2 199.1 Monday, April 10, 2006 12:53:07 PM:000 10.1 224.9 201.7 Report 06-0413 Chart 250-200 2 of 7

Monday, April 10, 2006 12:53:12 PM:000 10.2 224.7 201.4 Monday, April 10, 2006 12:53:17 PM:000 10.3 224.4 200.7 Monday, April 10, 2006 12:53:22 PM:000 10.3 224.1 201.5 Monday, April 10, 2006 12:53:27 PM:000 10.3 224 201.2 Monday, April 10, 2006 12:53:32 PM:000 10.2 223.7 197.8 Monday, April 10, 2006 12:53:37 PM:000 10 223.6 200.8 Monday, April 10, 2006 12:53:42 PM:000 10 223 201.1 Monday, April 10, 2006 12:53:47 PM:000 9.9 223 201.2 Monday, April 10, 2006 12:53:52 PM:000 10 222.7 201.3 Monday, April 10, 2006 12:53:57 PM:000 10.1 222.7 200.2 Monday, April 10, 2006 12:54:02 PM:000 10.1 222.2 200.4 Monday, April 10, 2006 12:54:07 PM:000 10.2 222.1 200.2 Monday, April 10, 2006 12:54:12 PM:000 10.2 221.9 202.4 Monday, April 10, 2006 12:54:17 PM:000 10.2 221.8 200.8 Monday, April 10, 2006 12:54:22 PM:000 10.2 221.4 200.7 Monday, April 10, 2006 12:54:27 PM:000 10.2 221.4 200.9 Monday, April 10, 2006 12:54:32 PM:000 10.2 221 200.5 Monday, April 10, 2006 12:54:37 PM:000 10.2 220.8 200.9 Monday, April 10, 2006 12:54:42 PM:000 10.2 220.8 201.1 Monday, April 10, 2006 12:54:47 PM:000 10.1 220.5 201 Monday, April 10, 2006 12:54:52 PM:000 10 220.4 202 Monday, April 10, 2006 12:54:57 PM:000 10 220.1 202.4 Monday, April 10, 2006 12:55:02 PM:000 10.1 219.8 198.1 Monday, April 10, 2006 12:55:07 PM:000 10.2 219.3 200.6 Monday, April 10, 2006 12:55:12 PM:000 10.2 219 200.6 Monday, April 10, 2006 12:55:17 PM:000 10.2 218.2 199.6 Monday, April 10, 2006 12:55:22 PM:000 10.2 218.1 201.3 Monday, April 10, 2006 12:55:27 PM:000 10.2 217.9 198.6 Monday, April 10, 2006 12:55:32 PM:000 10.3 217.9 197.5 Monday, April 10, 2006 12:55:37 PM:000 10.4 217.8 202.3 Monday, April 10, 2006 12:55:42 PM:000 10.4 217.4 204.1 Monday, April 10, 2006 12:55:47 PM:000 10.4 216.7 203.4 Monday, April 10, 2006 12:55:52 PM:000 10.3 216.4 202.4 Monday, April 10, 2006 12:55:57 PM:000 10.3 216.3 198.6 Monday, April 10, 2006 12:56:02 PM:000 10.4 216.3 198.7 Monday, April 10, 2006 12:56:07 PM:000 10.4 216.2 201 Monday, April 10, 2006 12:56:12 PM:000 10.4 215.3 199.9 Monday, April 10, 2006 12:56:17 PM:000 10.4 214.7 201.8 Monday, April 10, 2006 12:56:22 PM:000 10.5 214.4 201.3 Monday, April 10, 2006 12:56:27 PM:000 10.4 214.2 199.1 Monday, April 10, 2006 12:56:32 PM:000 10.5 213.9 199 Monday, April 10, 2006 12:56:37 PM:000 10.4 213.8 200.2 Monday, April 10, 2006 12:56:42 PM:000 10.4 213.1 200.3 Monday, April 10, 2006 12:56:47 PM:000 10.4 212.8 200.2 Monday, April 10, 2006 12:56:52 PM:000 10.4 212.5 200.2 Monday, April 10, 2006 12:56:57 PM:000 10.3 212.4 199.7 Monday, April 10, 2006 12:57:02 PM:000 10.4 212 200.3 Monday, April 10, 2006 12:57:07 PM:000 10.4 211.9 200.7 Monday, April 10, 2006 12:57:12 PM:000 10.4 211.6 200.8 Monday, April 10, 2006 12:57:17 PM:000 10.4 211.5 200.2 Monday, April 10, 2006 12:57:22 PM:000 10.4 211.4 200.1 Monday, April 10, 2006 12:57:27 PM:000 10.4 211.3 200.9 Report 06-0413 Chart 250-200 3 of 7

Monday, April 10, 2006 12:57:32 PM:000 10.4 211 200.1 Monday, April 10, 2006 12:57:37 PM:000 10.5 210.9 199.8 Monday, April 10, 2006 12:57:42 PM:000 10.5 210.5 199.6 Monday, April 10, 2006 12:57:47 PM:000 10.5 210.2 199.8 Monday, April 10, 2006 12:57:52 PM:000 10.4 209.8 199.7 Monday, April 10, 2006 12:57:57 PM:000 10.5 209.8 199.7 Monday, April 10, 2006 12:58:02 PM:000 10.6 209.8 200.9 Monday, April 10, 2006 12:58:07 PM:000 10.4 209.7 200.4 Monday, April 10, 2006 12:58:12 PM:000 10.4 209.5 199.6 Monday, April 10, 2006 12:58:17 PM:000 10.3 209.1 199.3 Monday, April 10, 2006 12:58:22 PM:000 10.4 208.8 199.8 Monday, April 10, 2006 12:58:27 PM:000 10.5 208.7 198.8 Monday, April 10, 2006 12:58:32 PM:000 10.4 208.7 199 Monday, April 10, 2006 12:58:37 PM:000 10.3 208.7 197.8 Monday, April 10, 2006 12:58:42 PM:000 10.3 208.6 197.1 Monday, April 10, 2006 12:58:47 PM:000 10.4 208.4 199.3 Monday, April 10, 2006 12:58:52 PM:000 10.2 208 200.6 Monday, April 10, 2006 12:58:57 PM:000 10.1 207.7 199.7 Monday, April 10, 2006 12:59:02 PM:000 10.2 207.6 200.1 Monday, April 10, 2006 12:59:07 PM:000 10 207.6 200.6 Monday, April 10, 2006 12:59:12 PM:000 9.9 207.5 200.6 Monday, April 10, 2006 12:59:17 PM:000 10 207.4 201.6 Monday, April 10, 2006 12:59:22 PM:000 9.9 207.3 201.3 Monday, April 10, 2006 12:59:27 PM:000 9.9 207.2 202 Monday, April 10, 2006 12:59:32 PM:000 9.8 207 202.7 Monday, April 10, 2006 12:59:37 PM:000 9.8 207 203.3 Monday, April 10, 2006 12:59:42 PM:000 9.9 206.9 199.8 Monday, April 10, 2006 12:59:47 PM:000 9.9 206.9 198.9 Monday, April 10, 2006 12:59:52 PM:000 10 206.9 199.7 Monday, April 10, 2006 12:59:57 PM:000 10.1 206.8 200.8 Monday, April 10, 2006 1:00:02 PM:000 10.1 206.7 201.8 Monday, April 10, 2006 1:00:07 PM:000 10.1 206.7 200.2 Monday, April 10, 2006 1:00:12 PM:000 10.1 206.7 200.9 Monday, April 10, 2006 1:00:17 PM:000 10.3 206.7 201.7 Monday, April 10, 2006 1:00:22 PM:000 10.3 206.5 201.7 Monday, April 10, 2006 1:00:27 PM:000 10.4 206.5 199.3 Monday, April 10, 2006 1:00:32 PM:000 10.4 206.5 199.3 Monday, April 10, 2006 1:00:37 PM:000 10.4 206.4 200.4 Monday, April 10, 2006 1:00:42 PM:000 10.4 206.3 201 Monday, April 10, 2006 1:00:47 PM:000 10.2 205.9 201.3 Monday, April 10, 2006 1:00:52 PM:000 10.2 205.9 199.5 Monday, April 10, 2006 1:00:57 PM:000 10.3 206 199.2 Monday, April 10, 2006 1:01:02 PM:000 10.2 206 200.2 Monday, April 10, 2006 1:01:07 PM:000 10.1 206 200.8 Monday, April 10, 2006 1:01:12 PM:000 10 206 201.3 Monday, April 10, 2006 1:01:17 PM:000 10 205.9 199 Monday, April 10, 2006 1:01:22 PM:000 10.1 205.8 199.7 Monday, April 10, 2006 1:01:27 PM:000 10.2 205.8 200.4 Monday, April 10, 2006 1:01:32 PM:000 10.2 205.7 201.9 Monday, April 10, 2006 1:01:37 PM:000 10.2 205.7 201.1 Monday, April 10, 2006 1:01:42 PM:000 10.2 205.6 199.3 Monday, April 10, 2006 1:01:47 PM:000 10.3 205.6 200.4 Report 06-0413 Chart 250-200 4 of 7

Monday, April 10, 2006 1:01:52 PM:000 10.2 205.6 202 Monday, April 10, 2006 1:01:57 PM:000 10.2 205.4 203.1 Monday, April 10, 2006 1:02:02 PM:000 10.2 205.2 203.5 Monday, April 10, 2006 1:02:07 PM:000 10.3 205.2 197.8 Monday, April 10, 2006 1:02:12 PM:000 10.4 205.2 196.6 Monday, April 10, 2006 1:02:17 PM:000 10.4 205.1 198.7 Monday, April 10, 2006 1:02:22 PM:000 10.3 205 200.5 Monday, April 10, 2006 1:02:27 PM:000 10.4 205 201.3 Monday, April 10, 2006 1:02:32 PM:000 10.5 205 200.1 Monday, April 10, 2006 1:02:37 PM:000 10.4 204.9 199.8 Monday, April 10, 2006 1:02:42 PM:000 10.3 204.9 200.9 Monday, April 10, 2006 1:02:47 PM:000 10.3 204.9 202.4 Monday, April 10, 2006 1:02:52 PM:000 10.4 204.8 201.9 Monday, April 10, 2006 1:02:57 PM:000 10.3 204.7 202.3 Monday, April 10, 2006 1:03:02 PM:000 10.3 204.6 203.4 Monday, April 10, 2006 1:03:07 PM:000 10.3 204.5 204 Monday, April 10, 2006 1:03:12 PM:000 10.3 204.5 204.4 Monday, April 10, 2006 1:03:17 PM:000 10.3 204.5 204.7 Monday, April 10, 2006 1:03:22 PM:000 10.1 204.5 205 Monday, April 10, 2006 1:03:27 PM:000 10.2 204.5 205.3 Monday, April 10, 2006 1:03:32 PM:000 10.2 204.4 205.3 Monday, April 10, 2006 1:03:37 PM:000 10.1 204.3 205.4 Monday, April 10, 2006 1:03:42 PM:000 10.1 204.3 205.5 Monday, April 10, 2006 1:03:47 PM:000 10.1 204.3 205.6 Monday, April 10, 2006 1:03:52 PM:000 10.2 204.3 205.9 Monday, April 10, 2006 1:03:57 PM:000 10 204.3 206 Monday, April 10, 2006 1:04:02 PM:000 10.1 204.3 206 Monday, April 10, 2006 1:04:07 PM:000 10.1 204.3 206.1 Monday, April 10, 2006 1:04:12 PM:000 10.1 204.3 206.1 Monday, April 10, 2006 1:04:17 PM:000 10.1 204.3 206.2 Monday, April 10, 2006 1:04:22 PM:000 10.1 204.3 206.2 Monday, April 10, 2006 1:04:27 PM:000 10 204.3 206.2 Monday, April 10, 2006 1:04:32 PM:000 10 204.3 203.9 Monday, April 10, 2006 1:04:37 PM:000 10 204.3 202.3 Monday, April 10, 2006 1:04:42 PM:000 10.1 204.3 201.4 Monday, April 10, 2006 1:04:47 PM:000 10 204.3 200.9 Monday, April 10, 2006 1:04:52 PM:000 10 204.3 201.8 Monday, April 10, 2006 1:04:57 PM:000 10 204.3 202.4 Monday, April 10, 2006 1:05:02 PM:000 10 204.3 201.3 Monday, April 10, 2006 1:05:07 PM:000 10 204.3 200.4 Monday, April 10, 2006 1:05:12 PM:000 10 204.4 200.2 Monday, April 10, 2006 1:05:17 PM:000 10.1 204.4 201.4 Monday, April 10, 2006 1:05:22 PM:000 10.1 204.4 202.5 Monday, April 10, 2006 1:05:27 PM:000 10 204.4 202.9 Monday, April 10, 2006 1:05:32 PM:000 10 204.4 201 Monday, April 10, 2006 1:05:37 PM:000 9.9 204.3 200.5 Monday, April 10, 2006 1:05:42 PM:000 9.9 204.2 200.4 Monday, April 10, 2006 1:05:47 PM:000 9.9 204.1 200.8 Monday, April 10, 2006 1:05:52 PM:000 10 204.1 201.8 Monday, April 10, 2006 1:05:57 PM:000 10 204.1 201.8 Monday, April 10, 2006 1:06:02 PM:000 10 204 201.1 Monday, April 10, 2006 1:06:07 PM:000 10 204 200.8 Report 06-0413 Chart 250-200 5 of 7

Monday, April 10, 2006 1:06:12 PM:000 10 204.1 200.3 Monday, April 10, 2006 1:06:17 PM:000 10 203.8 200.6 Monday, April 10, 2006 1:06:22 PM:000 9.8 203.7 202 Monday, April 10, 2006 1:06:27 PM:000 9.8 203.6 202.5 Monday, April 10, 2006 1:06:32 PM:000 9.7 203.4 201.8 Monday, April 10, 2006 1:06:37 PM:000 9.7 203.4 199.8 Monday, April 10, 2006 1:06:42 PM:000 9.8 203.3 199.4 Monday, April 10, 2006 1:06:47 PM:000 9.5 203.2 200.4 Monday, April 10, 2006 1:06:52 PM:000 9.5 203.2 201 Monday, April 10, 2006 1:06:57 PM:000 9.5 203.3 200.3 Monday, April 10, 2006 1:07:02 PM:000 9.6 203.3 199.7 Monday, April 10, 2006 1:07:07 PM:000 9.6 203.2 200.5 Monday, April 10, 2006 1:07:12 PM:000 9.6 203.2 201.4 Monday, April 10, 2006 1:07:17 PM:000 9.5 203.2 202.2 Monday, April 10, 2006 1:07:22 PM:000 9.5 203.2 201.6 Monday, April 10, 2006 1:07:27 PM:000 9.5 203.2 199.7 Monday, April 10, 2006 1:07:32 PM:000 9.6 203.2 199.7 Monday, April 10, 2006 1:07:37 PM:000 9.6 203.1 200.1 Monday, April 10, 2006 1:07:42 PM:000 9.5 203.1 200.1 Monday, April 10, 2006 1:07:47 PM:000 9.5 203.1 200.8 Monday, April 10, 2006 1:07:52 PM:000 9.7 203.2 201.3 Monday, April 10, 2006 1:07:57 PM:000 9.6 203.2 200.4 Monday, April 10, 2006 1:08:02 PM:000 9.6 203.1 200.4 Monday, April 10, 2006 1:08:07 PM:000 9.6 203.1 200.6 Monday, April 10, 2006 1:08:12 PM:000 9.5 203 197.8 Monday, April 10, 2006 1:08:17 PM:000 9.4 202.9 197.8 Monday, April 10, 2006 1:08:22 PM:000 9.5 202.9 199 Monday, April 10, 2006 1:08:27 PM:000 9.5 202.9 200.1 Monday, April 10, 2006 1:08:32 PM:000 9.6 202.9 200.8 Monday, April 10, 2006 1:08:37 PM:000 9.7 202.9 201.4 Monday, April 10, 2006 1:08:42 PM:000 9.6 202.9 200.7 Monday, April 10, 2006 1:08:47 PM:000 9.5 202.8 200.1 Monday, April 10, 2006 1:08:52 PM:000 9.4 202.8 199.7 Monday, April 10, 2006 1:08:57 PM:000 9.3 202.9 199.8 Monday, April 10, 2006 1:09:02 PM:000 9.6 202.8 198.2 Monday, April 10, 2006 1:09:07 PM:000 9.6 202.8 198.6 Monday, April 10, 2006 1:09:12 PM:000 9.6 202.8 199.5 Monday, April 10, 2006 1:09:17 PM:000 9.5 202.8 200.3 Monday, April 10, 2006 1:09:22 PM:000 9.6 202.7 201 Monday, April 10, 2006 1:09:27 PM:000 9.6 202.7 200.8 Monday, April 10, 2006 1:09:32 PM:000 9.5 202.7 197.9 Monday, April 10, 2006 1:09:37 PM:000 9.4 202.7 197.9 Monday, April 10, 2006 1:09:42 PM:000 9.5 202.7 198.9 Monday, April 10, 2006 1:09:47 PM:000 9.6 202.7 199.7 Monday, April 10, 2006 1:09:52 PM:000 9.5 202.7 200.4 Monday, April 10, 2006 1:09:57 PM:000 9.3 202.6 200.9 Monday, April 10, 2006 1:10:02 PM:000 9

202.7 199.7 Monday, April 10, 2006 1:10:07 PM:000 9.1 202.7 198.7 Monday, April 10, 2006 1:10:12 PM:000 9.2 202.5 198.8 Monday, April 10, 2006 1:10:17 PM:000 9.1 202.5 199.7 Monday, April 10, 2006 1:10:22 PM:000 9.3 202.5 200.7 Monday, April 10, 2006 1:10:27 PM:000 9.2 202.5 201 Report 06-0413 Chart 250-200 6 of 7

Monday, April 10, 2006 1:10:32 PM:000 9.2 202.5 200.9 Monday, April 10, 2006 1:10:37 PM:000 9.1 202.5 197.6 Monday, April 10, 2006 1:10:42 PM:000 9.1 202.4 197.6 Monday, April 10, 2006 1:10:47 PM:000 9.2 202.3 198.8 Monday, April 10, 2006 1:10:52 PM:000 9.2 202.3 199.3 Monday, April 10, 2006 1:10:57 PM:000 9.2 202.3 200.2 Monday, April 10, 2006 1:11:02 PM:000 9.2 202.3 200.7 Monday, April 10, 2006 1:11:07 PM:000 9.3 202.4 201.3 Monday, April 10, 2006 1:11:12 PM:000 9.3 202.4 201.4 Monday, April 10, 2006 1:11:17 PM:000 9.2 202.3 201.7 Monday, April 10, 2006 1:11:22 PM:000 9.1 202.3 199.2 Monday, April 10, 2006 1:11:27 PM:000 9.2 202.3 199.1 Monday, April 10, 2006 1:11:32 PM:000 9.3 202.2 199.5 Report 06-0413 Chart 250-200 7 of 7