Peripheral Oxide Utility:

Comanche Peak 2 Assembly: JW07 Face:

3 Date:

16-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.1 0.6

-0.9

-0.6 0.0

-0.4

-1.1 6.1 0.5

-0.6

-0.1

-0.6

-0.2

-1.1 7.1 1.0

-0.2 1.2 0.4 0.9

-0.1 8.1 0.5 0.6 1.8

-0.6 0.8 0.0 9.1

-0.1 0.9 2.3

-0.7 1.5

-0.1 10.1

-0.3 2.0 1.1 0.2 1.5 1.0 11.1 0.9 2.5 0.9

-0.1 1.6 0.2 12.1 0.7 1.9 1.1 0.7 1.7 0.9 13.1 1.0 1.7 1.1

-0.1 1.6 0.7 14.1 1.0 1.7 1.4 1.2 1.6 1.2 15.1 0.8 2.3 1.8

-0.2 2.2 1.1 16.1 1.2 1.5 2.5 0.5 2.4 2.2 17.1 1.1 2.5 1.2 2.0 2.9 2.6 18.1 1.8 2.8 1.9 1.0 3.5 1.9 19.1 1.9 2.9 2.6 2.2 3.4 1.2 20.1 2.7 2.9 2.9 1.5 3.0 3.4 21.1 0.6 2.5 2.7 1.6 2.9 1.1 22.1 1.6 3.4 2.3 1.7 4.8 1.5 23.1 1.6 2.2 2.1 1.8 3.0 1.5 29.5 0.2 1.3 2.6 3.4 2.3 2.1 30.5 1.0 2.4 2.0 2.6 1.3 1.5 31.5 1.6 1.0 1.9 3.0 1.1 1.7 32.5 1.4 0.9 1.5 2.9 1.9 2.1 33.5 2.7 0.7 1.9 2.9 2.3 2.0 34.5 1.8 1.2 3.1 2.8 2.7 2.7 35.5 2.8 2.4 2.2 3.2 1.9 1.4 36.5 2.7 1.9 4.8 4.5 2.8 3.4 37.5 2.3 2.8 2.1 3.8 3.3 1.9 38.5 3.6 2.8 3.2 4.4 3.0 2.3 39.5 3.1 3.2 3.8 5.2 4.1 3.2 40.5 2.3 2.9 2.9 5.0 2.8 2.6 41.5 3.4 3.6 3.8 6.2 4.1 3.3 42.5 2.3 1.9 3.6 5.2 3.1 3.1 43.5 2.8 2.9 3.8 6.6 2.8 3.6 50.1 3.6 3.4 3.2 1.8 3.4 1.9 51.1 2.3 3.1 4.5 2.1 2.7 1.1 52.1 3.0 4.4 3.1 1.9 3.4 0.8 53.1 2.8 3.6 4.3 2.3 3.7 1.3 54.1 3.1 4.7 4.0 1.6 4.3 1.5 55.1 3.3 4.8 4.5 2.8 3.9 0.7

56.1 3.9 4.5 4.9 2.0 3.2 2.2 57.1 2.7 5.2 5.0 2.3 4.0 1.5 58.1 2.8 5.3 4.9 2.8 3.6 1.8 59.1 2.2 5.0 4.6 2.2 3.9 2.5 60.1 3.6 5.3 5.5 3.9 4.0 3.8 61.1 2.7 4.3 5.2 3.5 4.0 2.4 62.1 2.9 5.8 5.3 3.9 4.9 3.3 63.1 2.7 5.3 5.1 3.5 4.8 3.2 64.1 4.2 5.1 5.2 3.0 5.0 2.7 70.7 3.2 3.0 2.7 2.8 3.6 2.7 71.7 3.0 2.6 3.9 3.0 3.5 2.3 72.7 4.2 4.0 2.8 2.6 3.3 2.7 73.7 4.4 3.5 3.5 3.1 3.2 2.9 74.7 4.9 3.6 2.3 2.2 4.2 2.5 75.7 4.5 3.1 2.9 2.8 4.9 3.2 76.7 5.0 5.0 3.9 3.5 5.0 3.2 77.7 4.8 4.3 3.7 3.7 4.5 2.7 78.7 4.7 4.9 4.0 5.3 4.8 3.7 79.7 3.9 4.2 2.7 4.2 6.1 3.7 80.7 5.1 5.6 5.1 5.0 6.2 4.7 81.7 3.5 4.9 4.0 5.6 5.7 4.7 82.7 4.6 5.2 4.6 7.1 5.7 4.0 83.7 3.7 5.7 4.9 4.9 7.2 4.9 84.7 3.4 6.2 4.6 4.7 7.2 4.0 91.2 2.6 5.2 5.7 3.3 4.2 3.5 92.2 2.1 4.6 4.8 3.1 3.6 3.0 93.2 2.1 4.4 5.4 2.8 3.8 3.7 94.2 2.4 5.0 4.1 3.7 3.6 2.9 95.2 2.2 4.3 4.8 3.6 3.0 3.6 96.2 3.1 5.3 4.5 4.1 4.1 4.1 97.2 3.7 5.1 5.3 5.1 4.0 4.3 98.2 2.9 6.0 4.6 6.7 5.2 5.0 99.2 3.4 5.9 5.3 7.3 4.1 5.9 100.2 4.1 6.4 6.5 7.1 4.7 6.8 101.2 3.7 6.7 4.9 6.8 4.9 5.9 102.2 3.6 7.9 6.5 7.2 5.9 7.3 103.2 4.5 8.2 7.4 7.7 5.8 6.6 104.2 4.9 8.6 7.9 7.7 6.1 7.6 105.2 4.0 7.5 6.4 7.4 6.4 6.4 111.8 2.9 5.7 5.6 6.4 6.3 4.1 112.8 2.6 5.8 5.0 6.5 5.2 4.7 113.8 3.4 6.1 4.6 6.9 5.3 4.5 114.8 3.2 7.2 5.2 6.2 5.4 4.7 115.8 3.6 7.5 5.4 5.9 5.0 4.9 116.8 4.3 8.5 5.8 6.8 5.4 4.9 117.8 4.9 8.2 6.0 7.3 5.5 5.2 118.8 6.6 9.7 5.8 7.2 6.1 5.2 119.8 7.3 10.2 6.7 6.9 6.1 5.9

120.8 6.3 9.3 6.9 7.0 6.2 5.9 121.8 6.7 9.5 7.3 6.8 7.3 5.9 122.8 6.7 7.7 7.5 7.6 6.5 6.1 123.8 6.7 8.4 7.3 6.9 7.7 5.9 124.8 5.7 7.5 8.4 7.2 7.2 7.1 125.8 5.7 7.9 7.9 7.2 7.1 6.7 132.3 3.1 6.3 6.6 5.1 4.7 4.6 133.3 3.6 6.4 5.8 4.6 4.6 4.1 134.3 4.7 4.1 6.5 4.6 5.1 3.9 135.3 4.2 4.7 6.3 5.1 4.2 3.9 136.3 3.8 4.5 6.6 5.6 4.6 4.2 137.3 4.2 2.6 7.5 5.0 4.0 4.0 138.3 5.8 3.1 7.6 6.9 4.0 3.5 139.3 3.9 3.1 8.1 4.3 3.4 3.1 140.3 3.6 3.5 6.6 5.7 3.6 2.7 141.3 2.7 5.0 7.2 5.1 4.0 3.2 142.3 3.4 2.2 5.7 4.6 3.7 3.2 143.3 3.9 2.6 10.4 5.9 4.1 3.5 144.3 2.9 2.3 6.0 2.8 2.6 2.4 145.3 2.5 2.8 5.4 4.0 2.3 2.4 146.3 4.7 3.9 7.1 3.8 2.6 3.3 max 7.3 10.2 10.4 7.7 7.7 7.6

Peripheral Rod Oxide (Comanche Peak 2, FA JW07, FA 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 20.0 40.0 60.0 80.0 100.0 Axial Elevation (inch)

Oxide Thickness (microns)

FR2 FR6 FR8 FR10 FR12 FR1

A JW07, FACE 3) 00.0 120.0 140.0 160.0 R12 FR14