Peripheral Oxide Utility: Comanche Peak 2 Assembly: HH80 Face: 1 Date: 17-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 6.2 11.0 10.7 7.8 10.8 8.0 6.9 7.2 12.0 12.1 8.2 10.3 8.5 8.4 8.2 12.7 12.9 9.8 11.1 10.1 9.7 9.2 12.9 12.8 13.9 12.1 11.3 9.8 10.2 13.5 13.4 13.9 11.9 10.8 10.5 11.2 14.5 14.7 12.3 12.4 11.4 10.6 12.2 16.2 16.3 18.0 12.5 11.8 11.5 13.2 15.1 15.9 14.6 14.9 13.2 11.2 14.2 14.6 16.1 14.1 14.8 12.9 12.3 15.2 15.1 16.0 14.5 13.9 13.2 11.7 16.2 15.5 16.9 15.4 14.1 15.7 12.9 17.2 16.3 17.3 14.7 13.9 14.1 13.1 18.2 15.7 16.8 15.4 14.8 14.5 14.7 19.2 16.5 17.5 16.9 14.0 15.7 14.4 20.2 17.9 18.3 14.5 15.2 15.8 14.5 21.2 16.9 16.9 14.2 16.0 16.1 15.9 22.2 17.6 18.5 13.9 16.8 16.2 14.7 23.2 16.8 15.7 13.9 16.5 14.2 12.6 29.7 15.1 13.1 13.0 15.4 12.3 12.6 30.7 14.1 15.3 13.6 14.8 14.2 12.2 31.7 15.9 14.5 14.3 15.2 13.7 12.8 32.7 18.1 14.6 14.3 16.4 13.0 12.3 33.7 16.3 15.7 14.8 14.4 13.8 13.9 34.7 16.6 16.2 15.1 14.0 14.7 15.1 35.7 18.2 18.5 14.8 17.6 13.5 15.4 36.7 16.2 17.1 15.5 17.8 14.1 15.8 37.7 18.0 17.4 16.4 16.8 15.0 16.9 38.7 17.6 18.8 16.0 16.0 15.9 17.9 39.7 18.3 19.9 16.2 17.6 17.0 17.8 40.7 18.3 18.4 16.0 18.1 15.8 16.7 41.7 17.4 18.7 16.4 18.5 16.7 17.5 42.7 17.7 19.2 17.0 16.7 17.5 18.0 43.7 20.0 18.7 16.7 17.6 17.8 19.3 50.3 18.4 19.4 18.3 16.8 16.7 15.2 51.3 19.4 18.2 20.7 17.8 17.5 15.5 52.3 19.4 19.9 17.6 17.2 16.4 16.1 53.3 21.2 19.8 18.3 17.1 18.1 18.5 54.3 20.4 20.3 18.4 19.3 18.2 17.4 55.3 23.0 19.9 18.8 18.9 16.8 17.6 56.3 24.4 20.5 19.8 20.6 17.5 19.2 57.3 25.9 21.5 19.2 18.3 17.4 19.7

58.3 23.6 23.1 18.7 18.6 17.4 19.2 59.3 24.6 22.7 20.5 20.7 18.3 19.7 60.3 23.0 24.3 20.5 20.2 17.6 19.5 61.3 24.6 23.6 21.5 21.0 19.3 20.7 62.3 24.0 23.8 22.0 20.8 17.9 20.1 63.3 23.6 24.2 21.0 19.8 18.0 19.8 64.3 25.2 24.9 22.6 21.1 18.4 19.6 70.8 20.0 18.8 19.5 18.2 17.3 18.4 71.8 22.3 20.4 19.0 18.6 19.5 18.8 72.8 23.6 20.5 18.5 20.1 18.7 20.6 73.8 24.4 20.7 18.8 22.5 18.9 20.9 74.8 26.1 20.8 20.3 22.5 20.8 23.3 75.8 27.6 22.5 20.1 22.6 20.1 23.5 76.8 26.0 24.0 21.4 23.8 19.5 24.2 77.8 28.4 24.2 22.5 26.5 20.7 25.8 78.8 28.8 25.0 23.2 25.8 20.0 25.6 79.8 30.1 25.1 23.7 26.7 20.6 27.1 80.8 30.1 25.8 24.8 26.8 20.7 27.1 81.8 27.6 26.6 25.3 25.5 20.8 26.4 82.8 28.4 27.3 23.8 27.7 22.5 25.7 83.8 26.6 25.5 24.3 25.7 22.0 24.8 84.8 27.2 24.8 25.2 23.8 22.2 25.4 91.4 25.5 24.5 23.7 24.4 21.9 21.7 92.4 26.9 26.2 24.7 25.4 22.4 23.1 93.4 34.0 27.5 24.2 25.2 23.4 27.4 94.4 40.3 29.3 23.7 27.1 24.3 31.2 95.4 46.0 28.9 24.1 29.0 24.2 34.9 96.4 52.4 29.0 25.8 29.9 24.9 37.1 97.4 54.5 30.4 27.5 33.4 23.5 39.3 98.4 56.3 33.6 28.4 34.6 24.9 40.2 99.4 54.9 36.4 26.8 35.2 25.4 41.4 100.4 53.9 37.0 26.1 33.9 25.0 41.3 101.4 54.8 36.1 27.2 34.8 27.0 40.3 102.4 51.6 35.4 27.6 32.7 26.8 38.3 103.4 45.6 33.8 26.4 30.3 26.0 35.4 104.4 39.5 31.2 26.2 29.8 28.2 32.0 105.4 35.8 29.1 26.4 29.1 27.0 30.3 111.9 39.2 29.7 27.6 31.5 26.0 31.9 112.9 49.9 33.3 29.5 29.8 27.0 38.9 113.9 66.5 36.2 29.8 35.8 26.3 49.0 114.9 79.7 41.3 31.1 41.8 26.3 58.2 115.9 83.8 46.9 32.8 49.0 27.0 65.3 116.9 87.0 50.3 31.9 53.6 28.7 72.8 117.9 90.2 51.5 30.2 53.9 30.9 75.4 118.9 91.6 54.5 29.4 55.9 30.9 77.3 119.9 90.2 56.8 32.0 56.5 34.9 77.2

120.9 90.3 59.0 31.5 53.6 33.0 74.0 121.9 87.4 57.8 30.5 50.7 35.2 67.7 122.9 75.9 54.5 30.0 45.0 34.0 61.3 123.9 62.7 50.2 31.9 39.3 31.2 53.9 124.9 51.8 45.8 32.8 35.6 30.2 47.2 125.9 44.9 41.2 32.1 33.5 29.2 39.0 132.5 34.6 31.7 26.2 27.5 23.1 29.6 133.5 42.0 32.8 26.5 28.7 23.4 34.2 134.5 43.2 33.1 26.3 28.4 22.9 37.9 135.5 43.8 33.4 25.9 28.5 23.5 38.2 136.5 42.2 33.4 24.2 28.7 24.0 38.1 137.5 38.7 31.3 23.6 26.9 23.4 33.4 138.5 37.4 29.7 22.9 26.6 23.5 31.3 139.5 31.0 26.3 22.5 23.2 21.0 28.7 140.5 27.5 24.3 23.1 20.8 19.9 23.2 141.5 24.4 23.4 22.6 21.0 19.8 21.7 142.5 23.1 22.5 21.9 19.5 17.7 19.7 143.5 22.9 22.9 21.1 20.3 18.1 19.0 144.5 21.8 20.1 19.6 21.8 17.3 19.2 145.5 18.1 19.5 16.8 17.2 15.9 15.4 146.5 17.6 18.9 17.1 17.1 17.7 14.5 max 91.6 59.0 32.8 56.5 35.2 77.3

Peripheral Rod Oxide ( Comanche Peak 2, FA HH80, FA 100.0 90.0 80.0 Oxide Thickness (microns) 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 0.0 20.0 40.0 60.0 80.0 100.0 Axial Elevation (inch)

FR2 FR6 FR8 FR10 FR12 FR

A HH80, FACE 1) 100.0 120.0 140.0 160.0 FR12 FR14