ML040370074

From kanterella
Jump to navigation Jump to search
Post Irradiation Examination - Assembly JW06, Face 3, 10/16/03
ML040370074
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 10/16/2003
From:
TXU Electric
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML040370074 (1)


Text

Peripheral Oxide Utility:

Comanche Peak 2 Assembly: JW06 Face:

3 Date:

16-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.1

-0.4

-0.2

-0.4

-0.5

-2.2

-0.6 6.1

-1.4 0.1 0.2

-0.8

-1.2

-0.6 7.1 0.0 1.9 0.9 0.2 0.2 0.1 8.1

-0.2 3.2 1.3

-0.2 0.2

-0.4 9.1 0.7 2.8 1.6 0.3 1.5 2.7 10.1 0.8 2.5 2.3 1.0 0.1 4.1 11.1 1.1 3.2 2.7 1.1 0.9 1.8 12.1 0.6 2.9 2.2 3.2 0.3 1.8 13.1 1.2 3.1 2.9 2.0 1.2 1.6 14.1 0.1 2.6 1.8 3.2 2.3 2.1 15.1 1.7 3.6 2.4 2.0 0.9 3.2 16.1 2.9 3.5 2.5 2.9 1.0 4.2 17.1 2.1 4.5 3.1 2.3 1.3 3.2 18.1 3.3 3.6 3.5 3.1 2.0 5.1 19.1 1.3 4.4 2.8 2.9 2.2 4.0 20.1 1.6 4.3 4.9 3.1 3.4 4.6 21.1 2.0 5.5 2.2 4.1 2.1 3.3 22.1 1.5 4.5 1.9 3.0 2.1 3.5 23.1 2.3 5.7 2.7 4.7 2.4 3.5 29.5 1.4 2.2 1.4 2.3 1.3 1.2 30.5 0.1 0.9 3.0 2.5 2.2 1.5 31.5 0.9 1.3 2.1 3.1 1.7 1.8 32.5 0.9 1.1 1.3 2.7 2.4 2.6 33.5 0.2 1.7 2.0 2.8 1.9 2.5 34.5 1.6 1.7 1.6 2.9 2.2 2.9 35.5 1.8 2.2 3.2 3.5 3.5 3.4 36.5 2.2 2.7 1.8 3.8 3.0 3.9 37.5 2.9 3.2 3.0 3.8 3.1 2.7 38.5 2.1 3.1 4.1 4.4 4.0 3.8 39.5 2.9 2.1 2.9 5.1 6.0 2.8 40.5 4.5 3.1 3.8 4.8 4.9 3.5 41.5 3.6 3.7 4.1 5.2 5.3 4.9 42.5 2.7 3.8 4.1 5.0 4.2 4.7 43.5 3.5 2.6 3.7 7.1 5.8 5.8 50.1 2.6 3.8 1.3 3.2 5.7 1.3 51.1 1.8 4.5 0.9 1.9 4.3 1.1 52.1 1.8 4.5 2.5 3.4 4.3 1.5 53.1 2.0 3.5 2.3 2.7 3.4 1.5 54.1 2.3 3.4 3.6 2.9 4.9 2.4 55.1 3.6 4.3 3.3 2.2 4.3 2.6 56.1 2.7 4.5 3.8 1.9 4.0 4.2 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 Oxide Thickness (microns)

57.1 4.4 3.9 5.0 3.3 5.4 4.1 58.1 2.3 4.5 4.8 3.4 4.2 4.5 59.1 2.8 4.1 5.9 5.1 4.5 3.5 60.1 3.5 5.1 5.1 5.2 4.8 4.6 61.1 2.0 4.3 4.7 5.0 3.9 4.0 62.1 2.4 5.1 3.8 5.2 5.4 5.5 63.1 1.2 3.9 3.1 5.1 4.6 5.5 64.1 1.4 5.9 4.2 5.8 4.1 7.9 70.7 4.9 3.8 5.4 4.2 4.7 5.2 71.7 3.6 4.3 4.7 3.8 5.4 3.7 72.7 4.3 4.5 4.8 5.2 4.8 4.6 73.7 4.0 4.9 4.6 4.5 6.7 3.6 74.7 5.2 4.1 5.4 4.4 6.2 6.4 75.7 5.5 5.0 6.5 6.8 7.5 4.8 76.7 5.5 4.9 7.2 6.4 5.8 5.7 77.7 6.0 5.6 7.6 6.4 6.2 4.4 78.7 4.7 6.8 7.0 6.8 6.1 6.1 79.7 5.3 5.5 8.9 8.0 7.0 7.5 80.7 5.0 7.6 7.6 7.6 7.3 7.4 81.7 5.0 7.3 7.5 8.6 7.1 8.3 82.7 5.9 7.9 7.6 8.0 7.7 8.0 83.7 5.4 7.4 8.1 8.4 9.1 8.5 84.7 5.7 7.3 7.1 9.0 7.9 9.9 91.2 2.3 6.3 5.7 5.2 5.5 5.4 92.2 3.1 5.8 3.8 5.7 6.9 7.2 93.2 1.9 6.3 5.4 5.9 6.4 6.9 94.2 2.6 5.9 5.4 5.6 7.5 8.0 95.2 4.1 6.7 6.5 6.4 7.4 7.3 96.2 3.7 7.0 6.4 5.4 6.9 6.2 97.2 5.4 7.7 7.2 7.3 7.3 6.4 98.2 4.6 9.0 8.2 7.3 7.6 7.2 99.2 6.0 9.0 7.4 7.5 7.2 6.1 100.2 5.1 9.0 9.2 9.3 8.8 8.4 101.2 6.0 8.4 7.9 8.1 6.6 7.2 102.2 5.6 9.0 8.5 8.4 7.4 7.7 103.2 5.8 9.0 8.5 8.8 8.3 8.8 104.2 5.7 8.9 7.8 8.0 6.6 7.9 105.2 6.0 8.6 8.1 7.9 8.3 10.1 111.8 4.8 6.7 6.9 7.7 5.4 6.2 112.8 6.2 7.7 6.1 8.2 6.0 5.8 113.8 7.2 6.5 6.9 9.3 6.6 5.4 114.8 7.5 6.9 6.6 8.2 8.3 5.5 115.8 7.7 7.5 7.4 6.3 8.0 5.2 116.8 6.8 7.1 8.1 6.6 7.5 5.8 117.8 8.0 7.7 7.9 8.4 7.7 7.1 118.8 7.2 7.4 9.1 7.7 6.4 6.0

119.8 6.5 9.8 10.0 8.3 7.7 7.1 120.8 7.7 9.7 9.2 8.9 7.6 6.2 121.8 6.1 7.8 8.7 7.8 7.6 7.1 122.8 6.4 7.9 9.3 8.9 7.5 6.4 123.8 5.0 8.0 9.1 9.0 6.6 6.4 124.8 7.5 7.5 9.3 10.4 7.2 7.1 125.8 7.3 8.5 10.8 10.5 7.4 7.0 132.3 6.7 6.9 6.1 6.7 5.7 6.7 133.3 5.5 6.0 4.2 7.0 5.3 6.3 134.3 5.2 5.8 4.1 5.7 5.2 5.6 135.3 5.5 6.9 4.4 5.2 4.8 5.1 136.3 6.6 8.0 5.2 5.0 4.4 5.5 137.3 4.3 5.5 4.8 5.9 4.6 4.7 138.3 4.6 8.0 3.8 6.8 3.3 4.4 139.3 4.1 5.7 4.9 4.6 4.1 3.3 140.3 5.0 6.2 3.3 6.1 3.5 3.9 141.3 6.0 8.6 4.0 7.2 4.4 5.6 142.3 6.0 5.0 3.0 6.4 3.8 3.5 143.3 7.7 6.0 5.0 5.2 5.9 3.8 144.3 5.4 5.3 3.9 6.1 4.0 2.5 145.3 3.0 5.1 2.1 4.9 2.6 2.9 146.3 3.8 5.5 5.2 4.4 2.4 1.9 max 8.0 9.8 10.8 10.5 9.1 10.1

Peripheral Rod Oxide (Comanche Peak 2, FA JW06, FACE 3) 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 20.0 40.0 60.0 80.0 100.0 120.0 Axial Elevation (inch)

(

)

FR2 FR6 FR8 FR10 FR12 FR14

FACE 3) 120.0 140.0 160.0 R14