ML040360717

From kanterella
Jump to navigation Jump to search
Post Irradiation Examination - Assembly HH83, Face 3, 10/21/03
ML040360717
Person / Time
Site: Comanche Peak 
Issue date: 10/21/2003
From:
TXU Electric
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML040360717 (1)


Text

Peripheral Oxide Utility:

Comanche 2 Cleaned Assembly: HH83 Face:

3 Date:

21-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 111.9 43.6 32.7 39.4 35.4 29.4 27.1 112.9 57.2 39.2 45.5 37.9 32.3 33.6 113.9 69.9 44.2 51.8 46.9 35.1 39.6 114.9 80.0 49.6 52.9 55.1 35.2 46.0 115.9 80.9 52.1 54.2 57.8 29.9 50.1 116.9 85.2 57.6 60.5 60.6 35.0 56.1 117.9 88.0 59.3 59.7 66.0 30.1 59.8 118.9 90.1 61.2 58.4 64.8 37.4 58.9 119.9 88.4 60.0 56.4 65.2 47.3 59.8 120.9 86.2 56.4 53.7 62.1 50.8 58.9 121.9 80.7 52.0 50.0 60.1 49.9 55.6 122.9 73.2 48.4 47.6 54.8 48.5 48.4 123.9 62.1 42.3 40.5 47.0 43.0 39.1 124.9 49.2 37.5 35.5 39.2 36.3 30.5 125.9 44.2 38.1 34.2 35.0 33.4 28.6 max 90.1 61.2 60.5 66.0 50.8 59.8 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 0.0 Oxide Thickness (microns)

Peripheral Rod Oxide After Crud Clean (Comanche Peak 2, FA HH83, FA 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 0.0 20.0 40.0 60.0 80.0 100.0 120.0 Axial Elevation (inch)

FR2 FR6 FR8 FR10 FR12 FR14

HH83, FACE 3) 120.0 140.0 160.0 FR14