Text
Peripheral Oxide Utility:
Comanche Peak 2 Assembly: JW01 Face:
1 Date:
15-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.1
-1.7
-1.0
-0.7
-2.2
-1.4
-2.7 6.1 0.3
-1.6
-2.2
-1.3
-2.2
-1.6 7.1 0.0 0.4
-1.0
-2.0
-1.3
-0.1 8.1 1.6
-0.4
-1.3
-2.0
-1.4
-0.3 9.1 1.0 0.8
-0.5
-1.0 0.1 1.5 10.1 1.3 0.2 0.4
-1.6 0.6 0.8 11.1 0.9 0.1
-0.3
-1.3 0.4 1.5 12.1 1.6 1.8 0.6
-0.9 1.0 1.6 13.1 1.5 1.6 0.3 0.2 1.1 1.5 14.1 0.9 1.6 1.6
-1.0 1.8 1.5 15.1 1.4 1.5 0.8
-0.7 1.1 1.4 16.1 0.5 2.2 1.0 0.4 2.1 2.0 17.1 1.6 1.7 1.7 0.4 1.7 2.2 18.1 1.2 2.0 1.6 0.4 1.5 2.0 19.1 2.3 2.5 2.0 1.4 1.7 2.0 20.1 1.9 2.5 0.9 1.7 1.8 2.5 21.1 1.4 2.2 2.0 1.7 2.8 2.9 22.1 2.2 1.8 2.2 3.2 1.9 4.9 23.1 0.8 2.3 2.7 1.1 2.6 2.4 29.5 0.6 0.5 0.6 1.6 0.0
-0.1 30.5
-0.1 0.5
-0.1 2.7
-0.4 0.0 31.5
-0.5 0.4 0.7 1.9
-0.2 0.6 32.5
-0.4 0.2
-0.6 2.1 0.4 0.5 33.5
-0.4 0.3 0.7 2.4 0.9 1.2 34.5 0.3 0.6 0.4 2.6 1.0 0.8 35.5 1.1 0.7 1.1 2.3 1.3 1.7 36.5 2.0 2.8 0.9 2.4 1.4 2.5 37.5 0.6 2.6 2.3 3.1 3.9 2.5 38.5 1.9 3.4 2.9 2.9 3.7 2.7 39.5 0.8 3.2 2.5 2.5 4.0 2.9 40.5 0.8 2.1 4.5 4.6 3.4 4.0 41.5 1.9 1.6 3.8 3.8 3.9 3.2 42.5 2.1 2.0 3.3 4.4 3.9 3.3 43.5 3.6 2.7 2.8 4.7 2.7 4.3 50.1 2.5 4.8 3.1 3.1 5.5 3.5 51.1 2.1 3.2 3.9 3.7 5.9 3.9 52.1 3.9 3.7 3.3 3.3 5.8 3.2 53.1 4.0 3.6 2.7 4.3 6.0 3.0 54.1 5.1 3.8 5.1 5.1 6.4 4.1 55.1 7.6 4.2 4.1 4.8 6.2 3.8 56.1 7.0 5.3 5.8 5.4 6.3 4.8 57.1 5.9 5.6 5.7 6.2 7.4 5.0 58.1 6.7 5.3 6.7 5.8 7.5 5.7 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 Oxide Thickness (microns)
59.1 7.5 5.6 7.7 7.2 8.1 6.0 60.1 6.9 6.0 8.0 7.4 7.5 6.7 61.1 6.8 6.5 8.4 7.1 8.4 7.4 62.1 6.9 7.4 8.1 6.5 7.5 7.7 63.1 7.3 5.7 7.6 5.5 7.6 7.5 64.1 6.8 6.1 7.9 5.9 7.6 7.9 70.7 2.9 5.1 4.8 4.3 4.1 3.7 71.7 3.8 5.2 6.7 4.8 5.9 5.5 72.7 3.2 4.3 4.7 4.6 5.8 4.6 73.7 3.3 4.4 5.1 5.1 5.3 5.8 74.7 3.9 5.5 6.6 5.6 5.0 4.4 75.7 3.6 5.4 6.8 5.9 5.3 5.3 76.7 4.6 6.4 6.1 6.7 6.1 6.2 77.7 5.1 7.6 6.0 7.1 5.1 5.9 78.7 5.8 8.5 6.6 7.0 5.4 6.7 79.7 5.6 7.8 8.5 8.5 5.7 6.9 80.7 6.1 7.0 6.4 8.2 6.5 6.9 81.7 5.9 8.3 6.9 8.4 5.8 7.9 82.7 6.7 8.1 6.6 7.5 6.3 7.5 83.7 7.0 8.4 7.5 8.0 6.4 7.8 84.7 7.0 9.3 8.0 7.7 7.0 8.5 91.2 5.9 7.6 8.1 7.2 5.2 4.8 92.2 6.0 7.2 6.7 7.3 5.2 6.2 93.2 5.5 6.6 6.2 8.1 5.1 6.4 94.2 5.8 6.4 6.5 7.5 5.4 7.1 95.2 5.6 6.3 7.6 8.4 5.3 6.9 96.2 6.6 7.9 9.2 7.8 5.8 6.7 97.2 7.7 7.8 10.1 8.3 6.9 7.7 98.2 7.5 8.8 11.1 8.5 8.3 7.2 99.2 8.2 9.1 11.7 9.3 7.0 8.6 100.2 7.4 9.6 13.1 9.3 8.6 8.2 101.2 7.0 8.2 11.1 9.2 8.2 7.7 102.2 7.8 9.3 12.4 11.6 9.5 8.3 103.2 8.5 9.7 11.4 11.0 8.9 7.3 104.2 7.2 9.7 11.8 11.6 8.8 7.5 105.2 7.7 9.7 12.3 11.3 8.3 8.0 111.8 6.2 10.5 6.5 7.3 6.2 5.4 112.8 6.4 9.8 5.8 6.8 6.6 5.0 113.8 6.8 8.0 6.1 6.7 6.6 5.9 114.8 8.3 8.7 6.0 7.0 7.2 5.7 115.8 8.1 8.2 7.3 6.9 7.9 6.9 116.8 8.9 9.5 8.5 7.3 8.7 6.0 117.8 9.0 10.4 10.1 8.1 8.4 7.3 118.8 9.3 9.5 9.7 7.7 8.6 7.5 119.8 9.5 11.1 10.7 10.2 10.2 8.6 120.8 9.6 12.0 10.2 9.6 9.8 9.4 121.8 9.8 11.1 10.6 10.3 10.9 9.2 122.8 9.5 10.2 10.3 11.1 11.0 10.0 123.8 8.9 10.4 10.0 9.8 10.2 8.9
124.8 8.8 10.7 11.9 10.7 10.8 10.5 125.8 8.9 10.9 11.1 9.6 10.7 8.6 132.3 7.1 8.7 8.7 7.4 7.1 5.9 133.3 5.9 8.0 7.8 7.1 6.6 6.1 134.3 7.7 8.8 6.9 7.0 6.5 5.3 135.3 7.1 10.0 7.9 6.5 5.6 6.4 136.3 7.9 10.0 6.4 7.1 6.2 5.8 137.3 7.8 11.5 9.2 6.6 6.3 6.1 138.3 7.8 11.5 7.8 6.5 6.6 5.8 139.3 9.3 14.6 9.6 6.5 5.0 5.0 140.3 7.0 10.8 7.3 6.1 5.5 5.8 141.3 8.4 10.5 8.2 6.0 5.5 4.1 142.3 7.2 7.4 9.1 5.4 7.4 5.0 143.3 8.9 7.8 6.9 4.9 5.4 4.0 144.3 6.8 6.4 9.1 3.1 4.5 4.6 145.3 5.6 5.3 7.2 2.7 3.4 3.0 146.3 6.6 6.8 6.4 3.0 3.5 3.0 max 9.8 14.6 13.1 11.6 11.0 10.5
Peripheral Rod Oxide (Comanche Peak 2, FA JW01, FACE 1) 0.0 5.0 0.0 5.0 0.0 5.0 0.0 5.0 0.0 5.0 0.0 0.0 20.0 40.0 60.0 80.0 100.0 120.0 Axial Elevation (inch)
FR2 FR6 FR8 FR10 FR12 FR14
ACE 1) 120.0 140.0 160.0 R14