ML040370076
| ML040370076 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 10/16/2003 |
| From: | TXU Electric |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML040370076 (1) | |
Text
Peripheral Oxide Utility:
Comanche Peak 2 Assembly: JW07 Face:
1 Date:
16-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.1 0.7 2.0 3.0
-1.0
-1.8
-0.6 6.1 1.2 2.2 3.2 0.2
-2.1
-0.6 7.1 0.5 3.0 2.3 1.8
-0.7
-0.6 8.1 2.0 4.2 2.6 2.0
-0.6 4.1 9.1 3.0 4.0 1.6 2.4 0.4 0.9 10.1 2.6 2.6 2.2 1.5 0.5 0.9 11.1 3.1 3.0 2.1 2.7 1.1 1.5 12.1 1.9 2.1 2.1 2.0 3.0 2.3 13.1 2.8 2.1 2.3 3.1 0.6 2.8 14.1 3.7 3.0 3.0 2.0 1.9 2.6 15.1 2.6 2.1 3.2 2.5 2.1 1.8 16.1 3.1 3.3 3.9 2.0 2.3 2.3 17.1 3.8 3.2 3.6 3.0 2.9 1.8 18.1 3.0 3.8 3.6 2.4 2.5 2.2 19.1 3.0 4.9 5.3 2.8 3.9 2.8 20.1 2.9 3.4 4.0 2.6 1.9 2.5 21.1 4.3 4.2 4.6 2.4 2.4 2.5 22.1 5.0 4.1 4.3 3.1 2.4 2.7 23.1 5.3 4.7 4.3 2.2 2.3 3.2 29.5 0.8 2.3 2.3 1.8 1.6 2.1 30.5 0.9 1.4 2.9 1.5 1.3 2.1 31.5 1.7 1.5 2.7 2.4 1.9 2.9 32.5 2.6 0.4 3.0 2.4 1.9 3.0 33.5 3.5 1.0 3.9 2.1 1.5 4.4 34.5 3.1 0.5 2.4 2.9 2.7 2.2 35.5 3.6 0.6 4.0 3.4 4.0 1.8 36.5 3.0 1.5 3.3 2.6 2.9 3.6 37.5 2.7 1.0 3.3 3.5 3.5 2.6 38.5 3.0 3.3 4.6 3.8 3.2 4.7 39.5 3.1 2.7 3.4 3.8 3.7 3.2 40.5 2.4 2.3 3.6 4.1 4.6 4.1 41.5 2.8 3.6 3.9 3.7 5.0 4.4 42.5 3.1 3.0 3.6 3.9 6.4 4.0 43.5 4.4 3.5 3.5 4.9 5.7 3.8 50.1 5.9 3.5 5.1 4.7 3.0 4.4 51.1 5.2 4.1 6.1 4.9 3.2 4.5 52.1 5.7 4.5 6.0 5.4 2.5 4.4 53.1 5.1 4.9 6.2 4.8 3.0 4.2 54.1 4.8 4.0 6.2 5.1 3.6 5.4 55.1 5.3 5.2 6.7 5.4 3.9 4.8 56.1 6.8 5.5 7.2 5.2 5.3 5.6 57.1 5.9 6.1 6.5 6.0 5.1 4.9
58.1 6.4 6.3 7.3 6.3 6.7 5.9 59.1 7.5 5.9 8.6 6.2 5.3 5.0 60.1 6.6 6.0 8.2 5.9 5.2 5.8 61.1 7.3 6.2 9.2 7.0 6.6 6.3 62.1 6.7 6.8 8.8 7.1 6.3 5.6 63.1 7.6 6.6 9.8 9.2 6.5 5.9 64.1 7.8 7.6 8.3 7.7 5.7 6.3 70.7 5.1 4.8 5.2 5.0 4.6 3.7 71.7 5.4 5.8 4.6 5.2 4.3 4.3 72.7 4.9 5.8 4.4 6.6 6.1 4.3 73.7 5.5 7.1 5.8 6.3 6.5 4.2 74.7 5.6 7.1 8.1 8.2 7.1 5.3 75.7 6.0 7.7 7.8 7.2 7.0 4.9 76.7 5.9 8.3 8.5 7.8 6.2 4.6 77.7 7.8 8.7 9.6 9.8 7.4 6.1 78.7 7.1 9.4 9.4 7.9 6.7 5.3 79.7 8.0 10.4 10.2 9.6 8.1 6.8 80.7 6.9 9.8 9.8 9.8 9.1 5.9 81.7 7.3 9.9 8.8 11.6 7.7 7.1 82.7 8.9 10.8 9.7 10.4 7.9 8.2 83.7 7.4 9.4 9.3 9.3 7.3 7.8 84.7 7.3 10.7 9.1 9.4 8.1 6.9 91.2 10.0 10.1 6.5 7.7 6.6 5.2 92.2 10.3 8.0 7.9 8.4 7.4 5.0 93.2 10.2 7.6 7.0 7.7 11.6 4.8 94.2 10.0 7.8 6.6 8.5 8.0 4.7 95.2 10.7 8.6 7.0 7.5 8.2 4.7 96.2 10.2 9.2 7.2 8.4 7.8 4.8 97.2 9.9 9.1 8.2 8.3 8.2 5.1 98.2 10.0 8.6 8.5 8.6 8.6 5.3 99.2 10.7 9.5 9.0 9.7 10.3 5.8 100.2 9.2 9.3 8.0 9.8 8.3 6.7 101.2 8.9 8.8 8.2 9.4 9.1 6.8 102.2 10.1 8.9 8.9 9.1 9.1 7.5 103.2 10.8 8.2 8.1 9.7 9.3 6.8 104.2 11.7 8.5 8.9 10.4 9.5 8.5 105.2 10.5 8.2 9.0 11.3 7.7 7.8 111.8 7.8 8.1 7.5 8.0 9.2 5.5 112.8 8.4 8.9 7.4 7.8 8.8 5.6 113.8 9.2 8.7 7.2 8.6 7.5 6.5 114.8 9.6 8.3 8.1 8.1 7.6 5.7 115.8 8.9 8.3 7.6 8.1 8.2 6.7 116.8 9.6 8.1 8.3 8.9 8.5 5.7 117.8 10.2 8.1 9.4 9.8 8.9 6.7 118.8 9.2 8.9 8.8 9.7 8.2 6.8 119.8 10.6 8.5 9.6 9.4 9.6 8.4 120.8 11.8 9.2 8.9 10.8 8.9 7.4 121.8 10.7 8.9 8.6 10.2 10.0 6.9 122.8 10.9 8.5 8.4 9.9 10.7 8.0
123.8 10.7 9.4 9.1 10.1 10.1 8.1 124.8 9.2 8.9 8.8 10.9 12.0 8.8 125.8 10.0 10.8 11.1 12.4 11.6 7.6 132.3 8.1 8.0 6.2 7.5 6.5 7.1 133.3 9.1 7.1 6.5 7.0 7.9 7.2 134.3 8.7 6.8 7.1 7.3 6.2 8.2 135.3 8.8 8.2 7.9 6.6 6.9 6.2 136.3 8.7 7.7 9.6 7.2 6.5 5.0 137.3 8.2 9.8 8.2 7.1 5.4 4.9 138.3 10.0 8.6 7.2 7.4 5.4 4.6 139.3 8.8 9.0 8.3 8.4 4.3 3.8 140.3 7.5 6.7 11.4 6.8 6.1 5.4 141.3 8.0 6.5 7.3 6.8 6.5 5.2 142.3 7.2 6.6 7.3 5.2 4.5 4.0 143.3 8.7 5.9 6.3 5.6 7.9 5.7 144.3 5.2 6.6 6.1 5.0 5.3 4.3 145.3 5.2 6.4 4.6 4.6 5.3 3.7 146.3 4.0 6.1 5.3 5.8 4.2 5.4 max 11.8 10.8 11.4 12.4 12.0 8.8
Peripheral Rod Oxide (Comanche Peak 2, FA JW07, FAC 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 20.0 40.0 60.0 80.0 100.0 Axial Elevation (inch)
Oxide Thickness (microns)
FR2 FR6 FR8 FR10 FR12 FR14
JW07, FACE 1) 00.0 120.0 140.0 160.0 R12 FR14