Peripheral Oxide Utility:

Comanche Peak 2 Assembly: JW05 Face:

4 Date:

16-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.1 0.0

-1.4

-1.5

-3.5

-0.7

-1.5 6.1 0.2

-0.1 0.1

-2.7

-1.7

-2.2 7.1

-0.7

-1.3

-0.8

-2.6

-0.7

-1.4 8.1

-1.3 3.4 0.0

-0.7

-0.7

-0.8 9.1

-0.4

-0.1

-0.1

-0.8 0.2

-0.6 10.1

-1.2

-0.9

-0.7

-0.5 0.7 0.1 11.1

-0.7 2.9 0.2 0.0 1.0 0.1 12.1

-0.9 0.8

-0.6 1.2 1.9 1.4 13.1 0.7 0.6 0.8 1.1 1.4 1.4 14.1 0.2 0.6

-0.3 0.8 1.8 2.2 15.1 0.2 1.0 0.2 1.0 0.8 1.8 16.1 0.6 0.7 0.5 0.9 0.8 1.3 17.1 0.6 2.5 0.7 1.0 1.1 1.7 18.1 1.6 2.4 1.2 1.3 1.0 1.6 19.1 2.2 2.2 1.7 1.6 1.9 2.4 20.1 2.9 2.6 1.4 2.3 2.0 2.1 21.1 2.1 2.5 1.8 1.4 2.5 4.2 22.1 1.0 3.0 0.9 2.5 2.1 2.9 23.1 0.5 3.3 1.2 1.6 1.9 4.0 29.5

-0.3 0.7 1.8 1.1 1.4 1.5 30.5

-0.4 0.6 0.4 1.0 2.3 0.3 31.5

-0.5 0.8 0.5 0.4 0.9 1.1 32.5 1.0 2.0 0.1

-0.1 0.9 1.0 33.5 1.5 2.1

-0.4

-0.2 0.7 1.9 34.5 1.7 5.5 0.9 0.0 1.0 1.4 35.5 2.2 6.1 0.1 0.1 1.2 2.1 36.5 1.2 5.4 1.8

-0.3 1.4 1.5 37.5 3.2 6.0 1.9 1.2 2.5 1.8 38.5 3.1 3.5 2.5 0.3 2.5 2.7 39.5 4.5 3.8 2.5 1.1 3.1 3.0 40.5 3.9 3.5 2.8 0.9 4.0 3.8 41.5 3.0 2.8 4.6 1.2 3.9 3.1 42.5 4.7 2.5 4.9 2.6 5.1 5.0 43.5 2.7 2.5 4.5 0.9 3.5 3.3 50.1

-0.1 3.1 2.5 0.4 0.4 1.4 51.1 1.1 1.3 2.5 1.7 0.4 0.9 52.1 1.1 1.9 1.2 1.5 0.6 0.5 53.1 0.3 1.7 1.7

-0.2 0.1 1.0 54.1 1.4 2.6 1.4 0.8 1.1 1.3 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 Oxide Thickness (microns)

55.1 0.4 2.7 2.4 1.2 0.9 0.3 56.1 1.5 2.1 3.2 1.4 1.2 1.2 57.1 3.4 4.0 3.7 3.0 2.1 1.8 58.1 1.8 2.8 4.5 2.6 1.7 2.2 59.1 1.0 5.2 3.3 3.0 2.0 1.9 60.1 1.2 3.2 3.1 2.7 2.2 1.5 61.1 1.7 4.0 2.4 2.4 3.1 2.7 62.1 3.2 3.2 3.7 3.0 3.7 2.5 63.1 3.9 4.1 3.3 3.4 3.0 2.5 64.1 3.0 4.8 5.0 3.1 3.7 2.8 70.7 0.8 3.0 1.5 1.4 2.0 1.7 71.7 1.3 3.3 2.4 1.9 2.3 2.3 72.7 4.2 2.8 1.4 1.4 1.6 2.2 73.7 1.2 1.8 1.6 5.1 1.4 1.2 74.7 1.6 3.3 0.8 1.2 1.3 1.6 75.7 1.2 1.8 1.1 1.1 1.6 1.9 76.7 2.1 2.5 1.8 2.4 2.3 1.3 77.7 2.5 4.9 1.5 2.2 2.7 2.4 78.7 2.8 2.4 2.4 2.5 3.5 1.7 79.7 2.1 2.6 2.4 2.8 3.1 3.8 80.7 2.2 2.5 3.6 2.5 4.0 3.5 81.7 2.2 5.3 3.7 1.9 3.2 3.6 82.7 2.3 3.1 3.6 3.1 4.4 4.5 83.7 3.2 4.3 6.0 3.1 3.6 4.1 84.7 3.5 5.3 6.4 3.8 5.2 5.5 91.2 2.7 3.7 3.1 1.7 2.5 1.5 92.2 2.4 4.3 3.6 2.5 2.9 4.1 93.2 2.8 4.0 3.0 2.1 2.0 2.2 94.2 1.5 2.7 2.5 1.9 2.8 2.6 95.2 2.9 3.7 4.8 1.7 2.5 1.8 96.2 2.1 4.1 3.8 1.8 2.0 2.5 97.2 3.6 4.5 4.8 3.2 2.6 3.7 98.2 3.8 5.1 4.2 2.6 3.2 3.9 99.2 4.5 5.2 5.8 4.7 3.9 3.6 100.2 4.7 6.0 4.7 4.0 4.4 3.3 101.2 5.1 5.2 4.9 5.5 4.0 4.1 102.2 5.9 6.0 6.3 5.6 4.8 4.5 103.2 4.8 6.5 6.5 6.4 4.4 5.5 104.2 6.3 6.5 7.1 6.1 4.8 5.1 105.2 5.9 9.0 8.0 5.9 6.2 4.2 111.8 3.5 5.3 5.6 3.5 4.4 5.1 112.8 4.6 4.9 4.7 4.6 6.4 4.6 113.8 4.2 4.7 5.3 1.8 5.3 5.9 114.8 4.2 3.4 4.2 1.5 5.0 4.1 115.8 4.3 3.4 4.7 2.3 5.2 6.0 116.8 4.6 2.9 4.6 2.3 5.7 4.6 117.8 6.4 4.7 5.4 2.8 6.0 5.3 118.8 6.0 6.7 6.1 2.7 6.0 5.8 119.8 6.2 5.1 4.6 2.5 5.9 5.2

120.8 6.2 7.3 6.8 3.4 6.9 6.2 121.8 5.7 6.3 5.3 3.8 6.4 5.3 122.8 6.4 6.8 6.8 3.9 6.2 7.0 123.8 6.0 6.7 5.9 5.6 6.6 7.5 124.8 6.6 6.2 5.5 6.1 6.5 6.7 125.8 7.0 8.2 7.0 9.4 7.5 7.5 132.3 3.1 5.9 6.9 1.9 3.9 3.6 133.3 3.7 2.9 4.7 2.0 4.4 2.7 134.3 5.1 3.3 5.8 0.3 3.2 3.8 135.3 4.8 3.8 6.0 0.6 3.3 2.1 136.3 4.1 3.3 7.5 0.3 2.6 2.1 137.3 3.1 4.6 7.2 1.5 3.4 3.9 138.3 2.4 3.2 5.6

-0.1 2.7 2.5 139.3 1.6 3.5 5.8

-0.2 2.8 1.9 140.3 2.1 2.4 4.6 0.1 3.7 3.0 141.3 1.0 3.0 4.9 0.0 2.6 1.8 142.3 1.6 3.1 3.9 1.0 4.8 2.3 143.3 2.2 4.1 5.0 0.4 4.2 1.6 144.3 1.3 3.6 4.8 1.2 3.4 1.1 145.3 2.5 2.0 2.4 1.2 2.0 2.6 146.3 1.1 2.3 3.5 0.6 1.8 1.2 max 7.0 9.0 8.0 9.4 7.5 7.5

Peripheral Rod Oxide (Comanche Peak 2, FA JW05, FACE 4) 0.0 5.0 0.0 5.0 0.0 5.0 0.0 5.0 0.0 5.0 0.0 0.0 20.0 40.0 60.0 80.0 100.0 120.0 Axial Elevation (inch)

FR2 FR6 FR8 FR10 FR12 FR14

4) 0.0 140.0 160.0