TXX-16020 ENCLOSURE 3

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 Technical Justification to Support Extended Volumetric Examination Interval for Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle to Safe End Dissimilar Metal Welds February 2016 Author: Alexandria M. Carolan*, Piping Analysis and Fracture Mechanics Verifier: Kiumars Setayesh*, Major Reactor Component Design and Analysis I Anees Udyawar*, Piping Analysis and Fracture Mechanics Approved: John L. McFadden*, Manager, Piping Analysis and Fracture Mechanics Carl J. Gimbrone*, Manager, Major Reactor Component Design and Analysis I

  • Electronicallyapproved records are authenticatedin the electronic document management system.

© 2016 Westinghouse Electric Company LLC All Rights Reserved O Westinghouse

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 FOREWORD This document contains Westinghouse Electric Company LLC proprietary information and data which has been identified by brackets. Coding (a,c,e) associated with the brackets sets forth the basis on which the information is considered proprietary. These codes are listed with their meanings in WCAP-72 11-NP Revision 8 (September 2015), "Proprietary Information and Intellectual Property Management Policies and Procedures."

The proprietary information and data contained in this report were obtained at considerable Westinghouse expense and its release could seriously affect our competitive position. This information is to be withheld from public disclosure in accordance with the Rules of Practice 10CFR2.390 and the information presented herein is to be safeguarded in accordance with 10CFR2.903. Withholding of this information does not adversely affect the public interest.

This information has been provided for your internal use only and should not be released to persons or organizations outside the Directorate of Regulation and the ACRS without the express written approval of Westinghouse Electric Company LLC. Should it become necessary to release this information to such persons as part of the review procedure, please contact Westinghouse Electric Company LLC, which will make the necessaiy arrangements required to protect the Company's proprietary interests.

The proprietary information in the brackets has been deleted in this report. The deleted information is provided in the proprietary version of this report (LTR-PAFM- 16-2-P Revision 0).

Page 2 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 1.0 Introduction Service induced cracking of the nickel-base alloy components and weidments have been occurring more and more fr'equently in recent years, resulting in the need to repair and/or replace these components. Such cracking and leakage have been observed in the reactor vessel upper and bottom head penetration nozzles as well as the dissimilar metal (DM) butt welds of the pressurizer and reactor vessel nozzles exposed to the high reactor coolant temperatures. These Pressurized Water Reactor (PWR) power plant field experiences and the potential for Primary Water Stress Corrosion Cracking (PWS CC) require reassessment of the examination frequency as well as the overall examination strategy for nickel-base alloy components and weldments. Code Case N-770-1 (Reference 1) provides the visual and volumetric inspection guidelines for the primary system piping DM butt welds to augment the current inspection requirements.

In accordance with Code Case N-770-1 guidelines, volumetric examinations are required for the unmitigated DM butt welds at the Reactor Vessel (RV) inlet nozzles every second inspection period not exceeding 7 years. A volumetric examination was previously performed for the Comanche Peak Unit 1 reactor vessel inlet nozzle to safe end DM butt welds during the Spring 2010 Refueling Outage (RFO). The next volumetric examination for the reactor vessel inlet nozzle DM welds is planned during the Spring 2016 RFO in accordance with Code Case N-770-

1. The fracture mechanics evaluation in this report will determine the impact of perfon-ning the volumetric examination on Comanche Peak Unit 1 during the Spring 2019 RFO. The time interval between the previous Unit 1 examination during the Spring 2010 RFO and the planned examination during the Spring 2019 RFO is 9 years, rather than the 7 years allowed by Code Case N-770-1. Therefore, Comanche Peak is seeking relaxation from the ASME Code Case N-770-1 examination requirement to be able to defer the volumetric examination to the Spring 2019 RFO as documented in an earlier relief request from Luminant Generation Company (Reference 2).

The technical justification to support this relief request is developed in this report based on a flaw tolerance analysis. The objective of the flaw tolerance analysis is to determine the largest initial axial and circumferential flaw sizes that could be left behind in service and remain acceptable until the next planned inspection. This maximum allowable initial flaw size can then be compared to a flaw size which would have been detected during the Spring 2010 RFO inlet nozzle DM weld examination based on the inspection detection capability.

The following sections provide a discussion of the methodology, geometry, loading and the flaw tolerance analyses performed to develop the technical justification for deviating from the volumetric examination requirements of Code Case N-770-l.

Page 3 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 2.0 Methodology In order to support the technical justification for deferring the volumetric examination from the Spring 2016 to Spring 2019 RIFO for Comanche Peak Unit 1, it is necessary to demonstrate the structural integrity of the RV inlet nozzle DM welds subjected to the PWSCC growth mechanism.

To demonstrate the structural integrity of the DM welds, it is essential to determine the maximum allowable initial flaw size that would be acceptable in the DM welds for the duration between examinations. This maximum allowable initial flaw size would be the largest flaw size that would remain acceptable until the Spring 2019 R!FO. The maximum allowable initial flaw size for a given plant operation duration can be detenmined by subtracting the PWSCC growth for that plant operation duration from the maximum allowable end-of-evaluation period flaw size, which is determined in accordance with ASME Code Section XI (Reference 3).

To determine the maximum allowable end-of-evaluation period flaw sizes and the crack tip stress intensity factors used for the PWSCC analysis, it is necessary to establish the stresses, crack geometry and the material properties at the locations of interest. The applicable loadings which must be considered consist of piping reaction loads acting at the DM weld regions and the welding residual stresses which exist in the region of interest.

The latest piping loads at the reactor vessel inlet nozzle DM weld locations are from WCAP-10197 (Reference 4). In addition to the piping loads, the effects of welding residual stresses are also considered. For PWSCC, the crack growth model for the DM weld material is based on that given in MRP-1 15 for Alloy 182 weld material (Reference 5). The nozzle geometry and piping loads used in the fracture mechanics analysis are shown in Section 3.0. A discussion of the welding residual stress distributions used for the DM welds is provided in Section 4.0. The determination of the maximum allowable end-of-evaluation period flaw sizes is discussed in Section 5.0.

The maximum allowable initial flaw size will be determined based on the crack growth due to the PWSCC growth mechanism at the RV inlet nozzle DM weld. The PWSCC crack growth is calculated based on the normal operating temperature and the crack tip stress intensity factors resulting from the normal operating steady state piping loads and welding residual stresses as discussed in Section 6.0. Section 7.0 provides the crack growth curves used in developing the technical justification to deviate from the Code Case N-770- 1 guidelines by deferring the volumetric inspection of the RV inlet nozzle DM welds from the Spring 2016 to Spring 2019 RIFO.

Page 4 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 3.0 Nozzle Geometry and Loads The DM weld geometry for the Comanche Peak Unit 1 Reactor Vessel inlet nozzles is based on the nozzle detail drawings (References 6.a and 6.b). The operating temperature of the reactor vessel inlet nozzles is based on the Comanche Peak Unit 1 relief request (Reference 2). The RV inlet nozzle geometry and normal operating temperature used in the analysis are summarized in Table 3-1.

The piping reaction loads at the RV inlet nozzle DM weld locations are based on WCAP- 10197 (Reference 4) and are summarized in Table 3-2. These loads are used in determining the maximum allowable end-of-evaluation period flaw sizes and the PWSCC growth.

Table 3-1 Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle Geometry and Normal Operating Temp*erature Dimension Outside Diameter (in) 33.05 Inside Diameter (in) 27.47 Thickness (in) 2.79 RV Inlet Nozzle Normal Operating Temperature = 555.74°F Table 3-2 Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle Piping Loads Forces Moments Laig(kips) (in-kips)

Fx Mx My Mz (Axial) (Torsion) (Bending) (Bending)

Deadweight 0.29 -180.42 51.67 -451.26 Pressure* 1333.5 100% Normal Thermal 2.5 -5500.74 386.92 -9764.41 Upset Thermal -411.30 -6187.38 -278.30 -11204.14 Faulted Thermal -2102.42 -9059.31 -3518.87 -17346.71 OBE (Operational Basis Earthquake) 137 1752 4893 1496 SSE (Safe Shutdown Earthquake) 164 2133 6267 1754 LOCA/Pipe Break 514 1192 6281 2291

  • Axial force due to normal operating pressure of 2.25 ksi Page 5 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 4.0 Dissimilar Metal Weld Residual Stress Distribution The plant specific welding residual stresses for Comanche Peak Unit 1 were not generated for this analysis; however, the welding residual stresses for the RV inlet nozzle DM weld will be based on South Texas (Reference 7), which has the same DM welding geometry, material, and configuration as Comanche Peak Unit 1. The key similarities between the two plants that are important in the welding residual stresses are the nozzle DM weld thickness, nozzle inside radius, and the safe end length. The DM weld thickness and inside radius along with the safe end length is calculated using dimensions from Reference 6.a and Reference 6.b for Comanche Peak Unit 1 (See Figure 4-1). The DM weld thickness and inside radius along with the safe end length for South Texas Unit 1 are from Reference 6.c and 6.d (See Figure 4-2). Figures 4-1 and Figure 4-2 provide a graphical comparison of these dimensions, which are also tabulated in Table 4-1.

As shown in Table 4-1 and Figures 4-1 and 4-2, the dimensions that are important to justify using South Texas RV inlet nozzle DM welding residual stresses for Comanche Peak are the same; therefore, the South Texas welding residual stresses will be used for Comanche Peak RV inlet nozzle DM weld. Furthermore, the normal operating temperature used in Reference 7 for South Texas Unit 1 is 563°F. The difference in this temperature compared to 555.74°F for Comanche Peak Unit 1 will have an insignificant impact on the welding residual stresses. The complete finite element modeling steps used in the generation of the welding residual stresses are provided below. These steps would be the same for Comanche Peak.

The FEA in Reference 7 is based on a two-dimensional axisymmetric model of the inlet nozzle DM weld region. The FEA model geometry includes a portion of the low alloy steel nozzle, the stainless steel safe end, a portion of the stainless steel piping, the DM weld attaching the nozzle to the safe end, and the stainless steel weld attaching the safe end to the piping. The FEA model also assumes a 3600 inside surface weld repair with a repair depth of 50% through the DM weld thickness, which is consistent with MRP-287 guidance (Reference 8). As documented in the Comanche Peak relief request (Reference 2), the RV inlet nozzle DM weld did not undergo any weld repairs during the original plant construction; therefore, the 50% weld repair through the DM weld thickness is conservative. The following fabrication sequence was simulated in the FEA and matches the information provided in the reactor vessel nozzle details drawings (References 6.a and 6.b for Comanche Peak and References 6.c and 6.d for South Texas):

  • The inlet nozzle was buttered with weld-deposited Alloy 82/182 material. Nozzle and buttering are post weld heat treated (PWHT) at 1,100°F.
  • The inlet nozzle was welded to the safe end ring forging using an Alloy 82/182 weld. The inner diameter of the dissimilar metal weld is machined to finished size.
  • An assumed 50% inside surface weld repair 360° around the circumference was' conservatively simulated in the Alloy 82/182 weld, which is consistent with MRP-287 (Reference 8).
  • Shop hydrostatic test was then performed at a pressure of 3110 psig and a temperature of 300°F.
  • The safe end was then machined for the piping side weld preparation.

Page 6 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-116-2-NP Revision 0

  • The machined safe end was welded to a long segment of stainless steel piping using a stainless steel weld.
  • A plant hydrostatic test was performed at 2485 psig pressure with a temperature of 300 0 F.
  • After the plant hydrostatic test, normal operating temperature and pressure was uniformly applied three times to consider any shakedown effects, after which the model was set to normal operating conditions.

Based on the FEA model, residual stresses at three different paths (centerline of the DM weld, nozzle side of the DM weld, and safe-end side of the DM weld) in the DM weld were obtained.

Additionally, a recommended path was provided, which is a representation of the limiting stress from all three paths through the DM weld. The recommended axial and hoop stress profiles were used in the generation of the crack growth charts to determine the maximum allowable initial flaw sizes (Section 7.0). The 100% normal operating hoop and axial welding residual stresses for the recommended stress profiles are shown in Figure 4-3.

Table 4-1 Comanche Peak Unit 1 and South Texas Unit 1 Dimension Comparison Comanche South 1

_____________ Peak Texas DM Weld Thickness (in) 2.79 2.79 -

Inside Radius (in) 27.47 27.47 Safe End Length (in) 4.06 4.06 Page 7 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 a,c,e Figure 4-1: Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle DM Weld Configuration (References 6.a and 6.b) a,c,e Figure 4-2: South Texas Unit 1 Reactor Vessel Inlet Nozzle DM Weld Configuration (References 6.c and 6.d)

Page 8 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 a,c,e Figure 4-3: Reactor Vessel Inlet Nozzle DM Weld 100% Normal Operating Recommended Residual Stress Profiles Through DM Weld with 50% Inside Surface Weld Repair Page 9 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 5.0 Maximum Allowable End-of-Evaluation Period Flaw Size Determination In order to develop the technical justification to defer the volumetric examination of the RV inlet nozzle DM welds from the Spring 2016 to Spring 2019 RFO, the first step is the determination of the maximum allowable end-of-evaluation period flaw sizes. The maximum allowable end-of-evaluation period flaw size is the size to which an indication is allowe@ to grow until the next inspection or evaluation period. This particular flaw size is determined based on the piping loads, geometry and the material properties of the component. The evaluation guidelines and procedures for calculating the maximum allowable end-of-evaluation period flaw sizes are described in paragraph IWB-3 640 and Appendix C of the ASME Section XI Code (Reference 3).

Rapid, nonductile failure is possible for ferritic materials at low temperatures, but is not applicable to the nickel-base alloy material. In nickel-base alloy material, the higher ductility leads to two possible modes of failure, plastic collapse or unstable ductile tearing. The second mechanism can occur when the applied J integral exceeds the J1c fracture toughness, and some stable tearing occurs prior to failure. If this mode of failure is dominant, then the load-carrying capacity is less than that predicted by the plastic collapse mechanism. The maximum allowable end-of-evaluation period flaw sizes of paragraph IWB-3 640 for the high toughness materials are determined based on the assumption that plastic collapse would be achieved and would be the dominant mode of failure. However, due to the reduced toughness of the DM welds, it is possible that crack extension and unstable ductile tearing could occur and be the dominant mode of failure.

To account for this effect, penalty factors called "Z factors" were developed in ASME Code Section XI, which are to be multiplied by the loadings at these welds. In the current analysis for Comanche Peak, Z factors based on Reference 9 are used in the analysis to provide a more representative approximation of the effects of the DM welds. The use of Z factors in effect reduces the maximum allowable end-of-evaluation period flaw sizes for flux welds and thus has been incorporated directly into the evaluation performed in accordance with the procedure and acceptance criteria given in IWB-3 640 and Appendix C of ASME Code Section XI. It should be noted that the maximum allowable end-of-evaluation period flaw sizes are limited to only 75% of the wall thickness in accordance with the requirements of ASME Section XI paragraph IWB-3640 (Reference 3).

The maximum allowable end-of-evaluation period flaw sizes determined for both axial and circumferential flaws have incorporated the relevant material properties, pipe loadings and geometry. Loadings under normal, upset, emergency and faulted conditions are considered in conjunction with the applicable safety factors for the corresponding service conditions required in the ASME Section XI Code. For circumferential flaws, axial stress due to the pressure, deadweight, thermal expansion, seismic and pipe break loads are considered in the evaluation.

As for the axial flaws, hoop stress resulting from pressure loading is used.

The maximum allowable end-of-evaluation period flaw sizes for the axial and circumferential flaws at the RV inlet nozzle DM welds are provided in Table 5-1. The maximum allowable end-of-evaluation period axial flaw size was calculated with an assumed aspect ratio (flaw length/flaw depth) of 2. The aspect ratio of 2 is reasonable because the axial flaw growth due to PWSCC is limited to the width of the DM weld configuration. For the circumferential flaw, a conservative Page 10 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 aspect ratio of 10 is used.

It should be noted that the resulting maximum allowable end-of-evaluation period flaw sizes were limited by the ASME Code limit of 75% of the weld thickness for both flaw configurations.

Table 5-1 Maximum End-of-Evaluation Period Allowable Flaw Sizes (Flaw Depth/Wall Thickness Ratio - a/t)

Axial Flaw Circumferential Flaw (Aspect Ratio = 2) (Aspect Ratio =10) 0.75 0.75 Page 11 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 6.0 PWSCC Crack Growth Analysis A PWSCC crack growth analysis was performed to determine the maximum allowable initial flaw size that would be acceptable based on ASME Section XI acceptance criteria (Reference 3) for the operating duration from the Spring 2010 to the Spring 2019 RFOs. The maximum allowable initial flaw size for the given plant operation duration is determined by subtracting the crack growth due to PWSCC for the specific plant operation duration from the maximum allowable end-of-evaluation period flaw size shown in Table 5-1.

Crack growth due to PWSCC is calculated for both axial and circumferential flaws using the normal operating condition steady-state stresses. For axial flaws, the stresses included pressure and residual stresses, while for circumferential flaws, the stresses considered are pressure, 100%

power normal thermal expansion, deadweight and residual stresses. The input required for the crack growth analysis is basically the information necessary to calculate the crack tip stress intensity factor (K1 ), which depends on the geometry of the crack, its surrounding structure and the applied stresses. The geometry and loadings for the nozzles of interest are discussed in Section 3.0 and the applicable residual stresses used are discussed in Section 4.0. Once K1 is calculated, PWSCC growth can be calculated using the applicable crack growth rate for the nickel-base alloy material (Alloy 182) from MRP-1 15 (Reference 5). For all inside surface flaws, the governing crack growth mechanism for the RV inlet nozzle is PWSCC.

Using the applicable stresses at the DM welds, the crack tip stress intensity factors can be determined based on the stress intensity factor expressions from API-579 (Reference 10). The through-wall stress distribution profile is represented by a 4 th order polynomial:

0-= 0-"+ 0-1(x/t+ n-2(x/t)2 + - 3 (x/t)3 + 0- 4 (X/t)4 Where:

0-0, 0-, n-2, u-3, and r"4are the stress profile curve fitting coefficients; x is the distance from the wall surface where the crack initiates to the crack tip; t is the wall thickness; and n- is the stress perpendicular to the plane of the crack.

The stress intensity factor calculations for semi-elliptical inside surface axial and circumferential flaws are expressed in the general form as follows:

4I j(/,at tRI)oj(~

j=0 Where:

a = Crack depth c = Half crack length along surface t Thickness of cylinder Page 12 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 R = Inside radius q* = Angular position of a point on the crack front Gj = Gj is influence coefficient forj~th stress distribution on crack surface (i.e., Go, G1, G2, G3, G4)

Q =The shape factor of an elliptical crack is approximated by:

Q =1 + l.464(a/c)" 65 for a/c < 1 or Q = 1 + 1.464(c/a) 1 65

" for a/c > 1 The influence coefficients at various points on the crack front can be obtained by using an interpolation method. Once the crack tip stress intensity factors are determined, PWSCC crack growth calculations can be performed using the crack growth rate below with the applicable normal operating temperature.

The PWSCC crack growth rate used in the crack growth analysis is based on the Electric Power Research Institute (EPRI) recommended crack growth curve for Alloy 182 material (Reference 5):

da ep[Q__ (1 T)]

Where:

da dt = Crack growth rate in rn/sec (in/hr)

Qg = Thermal activation energy for crack growth =130 kJ/mole (31.0 kcal/mole)

R = Universal gas constant = 8.3 14 x 10-3 kJ/mole-K (1.103 x i0-3 kcal/mole-0R)

T = Absolute operating temperature at the location of crack, K (0 R)

Tref = Absolute reference temperature used to normalize data -- 598.15 K (1 076.670 R)

= Crack growth amplitude

= 1.50 x 10-12 at 325°C (2.47 x 10-7 at 617°F) p3 = Exponent = 1.6 K = Crack tip stress intensity factor MPa*/m (ksiblin)

The normal operating temperature used in the crack growth analysis is 555.74°F at the RV inlet nozzle as reported in Reference 2. It should be noted that the fatigue crack growth mechanism is not considered in the crack growth analysis as it is considered to be small when compared to that due to the PWSCC crack growth mechanism at the reactor vessel inlet nozzle for the duration of interest. This is demonstrated by the low fatigue usage factor of 0.01014 at the inlet nozzle location of interest in the reactor vessel analytical report CENC- 1382 (Reference 11). Therefore, it is not necessary to consider fatigue crack growth in the evaluation.

Page 13 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-16-2-NP Revision 0 The PWSCC crack growth rate is highly dependent on the temperature at the location of the flaw, furthermore, the crack growth rate increases as the temperature increases. Therefore, during periods when the plant is not in operation, such as refueling outages or shutdowns, the temperature at the reactor vessel nozzles is low such that crack growth due to PWSCC is insignificant. Therefore, PWSCC crack growth calculation should be determined for the time interval when the plant is operating at full power. The amount of time when the plant is operating at full power is determined based on previous plant operation data and the anticipated outages scheduled until the next inspections. This operation duration at full power is referred to as Effective Full Power Years (EFPY). Plant operation data and projected future outage dates and durations were provided for Comanche Peak Unit 1 and are used to estimate the EFPY between the Spring 2010 to the Spring 2019 RFOs.

The determination of the EFPY based on plant operating data is shown in Table 6-1 for Comanche Peak Unit 1. Based on Table 6.-i, for the time interval between the Spring 2010 RFO and Spring 2019 RFO, Comanche Peak Unit 1 is estimated to operate at full power for 8.51 EFPY. The calculated EFPY values will be used in the determination of the maximum allowable initial flaw sizes in Section 7.0.

Table 6-1 Effective Full Power Year Estimation for Comanche Peak Unit 1 Cycle Refueling Outage EFPY 1RF14 Spring 2010 0 1RF15 Fall 2011 1.39*

1RF16 Spring 2013 1.4039*

1RF17 Fall 2014 1.4344*

1RF18 Spring 2016 1.42"*

1RF19 Fall 2017 1.43"*

1RF20 Spring 2019 1.43"*

I Cumulative EFPY 8.51 Notes: *Based on plant operation data.

    • Estimated based on anticipated outages.

Page 14 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 7.0 Technical Justification for Deferring the Volumetric Examination In accordance with ASME Code Case N-770-1 (Reference 1), the volumetric examination interval for the unmitigated reactor vessel inlet nozzle to safe end DM welds must not exceed 7 years. Comanche Peak Unit 1 is seeking relaxation from the ASME Code Case N-770-1 requirement in order to defer the volumetric examination of the reactor vessel inlet nozzle to safe end DM welds from the Spring 2016 to Spring 2019 RFO as discussed in an earlier relief request (Reference 2). Technical justification can be developed to support deferring the volumetric examination by calculating the maximum allowable initial flaw size that could be left behind in service and remain acceptable between the inspections. This maximum allowable initial flaw size can then be compared to a flaw size which would have been detected during the Spring 2010 RFO inlet nozzle DM weld examination based on the inspection detection capability.

The maximum allowable initial flaw depth is determined by subtracting the amount of PWSCC crack growth for a plant operation duration of 8.51 EFPY from the maximum allowable end-of-evaluation period flaw depth shown in Table 5-1. The end-of-evaluation period flaw depth is calculated based on the guidelines given in paragraph IWB-3 640 and Appendix C of the ASME Section XI Code (Reference 3). The PWSCC crack growth at the Alloy 82/182 weld is calculated based on the normal operating condition, piping loads, and the welding residual stresses at the DM weld as well as the crack growth model in MRP- 115 (Reference 5). The maximum allowable initial flaw depth was calculated for an axial flaw with an assumed aspect ratio of 2.

An aspect ratio of 2 is reasonable for the axial flaw due to the DM weld configuration since any PWSCC axial flaw growth is limited to the width of the weld. For the circumferential flaw, a conservative aspect ratio of 10 is used in the crack growth analysis.

The PWSCC crack growth analysis of the circumferential flaws considered two cases: normal operating piping loads (deadweight and normal thermal loads) with residual stresses from the recommended profile (shown in Figure 4-3) and normal operating piping loads without residual stresses in order to obtain the most limiting crack growth results since a portion of the axial residual stress profile is compressive. It was detelrmined that the case which included only piping loads and no residual stresses was limiting for circumferential flaws. The exclusion of residual stresses in the evaluation is conservative for the circumferential flaw evaluation.

The PWSCC crack growth curves and the maximum allowable initial flaw sizes for an axial flaw and a circumferential flaw are shown in Figures 7-1 and 7-2, respectively. The horizontal axis displays service life in Effective Full Power Years, and the vertical axis shows the flaw depth to wall thickness ratio (alt). The maximum allowable end-of-evaluation period flaw sizes are also shown in these figures for the respective flaw configurations. Based on the crack growth results from Figures 7-1 and 7-2, the maximum allowable initial flaw sizes for the axial and circumferential flaws are tabulated in Table 7-1.

Page 15 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 16-2-NP Revision 0 Table 7-1 Comanche Peak Unit 1 Maximum Allowable Initial Flaw Sizes Axial Flaw Circumferential Flaw (Aspect Ratio = 2) (Aspect Ratio = 10)

Maximum Allowable Initial Flaw Sie(/)0.057 0.336 Flaw Depth (in) 0.160 0.937 Flaw Length (in) 0.320 9.37 The flaw sizes shown in Table 7-1 are the largest axial and circumferential flaw sizes that could be left behind in service and remain acceptable from the Spring 2010 to Spring 2019 RFO for Comanche Peak Unit 1. In accordance with the Ultrasonic Testing (UT) detection and sizing requirements in ASME Section Xl Appendix VIII, Supplement 10 (Reference 3), the minimum required detectable flaw depth is 10% of the wall thickness. Therefore, the maximum allowable initial circumferential flaw size is above the minimum flaw depth requirement per the UT detection capabilities, and thus would have been reasonably detected at the previous inspection of the DM welds.

In addition to the required baseline volumetric UT examination of the RV inlet nozzle DM weld, Comanche Peak also conducted Eddy Current Testing (ET) on the RV inlet nozzle DM welds as noted in Reference 2. The ET examination is an additional means to detecting surface breaking indications on the inside surface of the DM weld. The Comanche Peak qualification process for the FT procedure is the same as that of the qualification procedures used at Farley, which followed the details discussed inReference 12. Per Reference 12, the qualification process and practical trial for the FT procedure is in accordance with European Network for Inspection Qualification (ENIQ) guidelines. More details are provided in Reference 12, which is a Nuclear Regulatory Commission (NRC) request for additional information response provided by Farley for justification of their ET procedure. Based on the qualification guidelines as discussed in Reference 12, the Eddy Current examination is capable of detecting fatigue and intergranular stress corrosion cracking (IGSCC)/ interdendritic stress corrosion cracking (IDSCC) cracks as small as 0.04" deep by 0.24" long.

The Comanche Peak FT inspection procedure (Reference 14) from Spring 2010 required that an indication with a depth of 0.08" and length of 0.28" or more be recorded. For Comanche Peak Unit 1, the maximum initial axial flaw depth is 0.160" and flaw length is 0.320" from Table 7-1, these particular flaw dimensions are greater than the Comanche Peak FT flaw depth of 0.08" and flaw length of 0.28". As a result, the calculated maximum allowable initial axial flaw size is large enough to have been detected during the last Spring 2010 RFO examination of the RV inlet nozzle DM welds at Comanche Peak Unit 1. Similar justification was used in the J.M. Farley Units 1 and 2 and also the South Texas Unit 1 RV inlet nozzle DM weld alternate inservice inspection relief request for axial initial flaw depth less than 10% of the through-wall thickness. Furthermore, the NRC staff in its response to the Farley relief request (Reference 13) and the South Texas relief request (Reference 15) accepted the use of the licensee's FT Page 16 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Rev ision 0 qualification process to justify the acceptability for initial flaw sizes less than 10% of the through-wall thickness when supplemented with volumetric examinations performed by UT as required by the ASME Code Case N-770-1.

Therefore, the maximum allowable initial axial and circumferential flaw sizes in Table 7-1 would have been detected during the Spring 2010 REQ inlet nozzle DM weld examination. Since, there were no indications found during the Spring 2010 RFO for the inlet nozzle DM weld as documented in Reference 2, the technical justification developed in this letter report can be used to defer the volumetric examination for the Comanche Peak Unit 1 RV inlet nozzle DM welds from the Spring 2016 RFO to the Spring 2019 RFO.

Page 17 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 0.8

"- - - ASME Maximum Allowable End-Of-Evaluation Period Flaw Size -

0.7 ... *--- - 4-0.6 1 0.4 -

[,-

I. 0.3 Maximum Initial Flaw Size Allowed During Spring 2010 RFO (a/t) --0.057 0.2 0.1 .. . i 0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Service Life (EFPY)

Figure 7-1: PWSCC Crack Growth Curve for Comanche Peak Unit 1 Inlet Nozzle Axial Flaw (DM weld), Aspect Ratio = 2 Page 18 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 0.8


ASME MxmmAlwbeEdO-vuainPeriod Flaw Size 0.7 --__ ___

0.6--Ealato 0.5 0.4 U Maximum Initial Flaw Size Allowed During Spring 2010 RFO (a/t) = 0.336 0.3 -*

a.

0.2 0.1 0

0 2 4 6 8 10 12 14 16 18 20 22 24 Service Life (EFPY)

Figure 7-2: PWSCC Crack Growth Curve for Comanche Peak Unit 1 Inlet Nozzle Circumferential Flaw (DM weld), Aspect Ratio = 10 Page 19 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0 8.0 Summary and Conclusions A volumetric examination of the reactor vessel inlet nozzle to safe end DM butt welds was performed during the Spring 2010 REO at Comanche Peak Unit 1. The next required volumetric examination is planned during the Spring 2016 RFO in accordance with Code Case N-770-1.

However, the volumetric examination will be deferred to the Spring 2019 REO for the reactor vessel inlet nozzle DM welds. Since the time interval between the previous examination and the planned examination exceeds 7 years, which deviates from the Code Case N-770-1 inspection interval requirements, a relief request (Reference 2) was submitted to the NRC seeking relaxation from the ASME Code Case N-770- 1 examination requirement and to defer the volumetric examination of the inlet nozzle DM welds.

This letter report provides technical justification to support the relaxation request by performing a flaw tolerance analysis to determine the largest initial axial and circumferential flaws that could be left behind in service and remain acceptable between the planned examinations. This maximum allowable initial flaw size can then be compared to any flaw size whieb would have been detected during the previous inlet nozzle DM weld examinations.

Based on the PWSCC crack growth analysis results from Section 7.0, the maximum allowable initial flaw sizes for the reactor vessel inlet nozzle DM welds are tabulated in Table 8-1 for Comanche Peak Unit 1. These allowable initial axial and circumferential flaw sizes have been shown to be acceptable in accordance with the ASME Section XI IWB-3 640 acceptance criteria tharough the Spring 2019 RFO for Comanche Peak Unit 1 taking into account of potential PWSCC crack growth since the last volumetric and surface examinations.

In accordance with the Ultrasonic Testing (UT) detection and sizing requirements in ASME Section XI Appendix VIII, Supplement 10 (Reference 3), the minimum required detectable flaw depth is 10% of the wall thickness. In addition to the UT examination of the RV inlet nozzle DM weld, supplemental Eddy Current Testing (ET) was performed on the RV inlet nozzle DM welds for Comanche Peak Unit 1. Based on the qualification guidelines as discussed in Reference 12, the Eddy Current examination is capable of detecting fatigue and IGSCC/IDSCC cracks as small as 0.04" deep by 0.24" long. The Comanche Peak ET inspection procedure (Reference 14) in Spring 2010 required that an indication with a depth of 0.08" and a length of 0.28" or more be recorded.

Based on the Comanche Peak Unit 1 results in Table 8-1, the calculated maximum allowable initial axial flaw size is large enough to have been detected during the last Spring 2010 RFO examination of the RV inlet nozzle DM welds. Similar justification was used in the J.M. Farley Units 1 and 2 and also for the South Texas Unit 1 RV inlet nozzle DM weld alternate inservice inspection relief request for axial initial flaw sizes less than 10% of the through-wall thickness. Furthermore, the NRC staff in its response to the Farley relief request (Reference 13) and the South Texas relief request (Reference 15) accepted the use of the licensee's ET qualification process to justify the acceptability for initial flaw sizes less than 10% of the through-wall thickness when supplemented with volumetric examinations performed by UT as required by the ASME Code Case N-770- 1. Therefore, deferring the volumetric examination for the Page 20 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 Comanche Peak Unit 1 RV inlet nozzle DM welds from the Spring 2016 RFO allowed by Code Case N-770-l to the Spring 2019 RFO is technically justified.

Table 8-1 Comanche Peak Unit 1 Maximum Allowable Initial Flaw Sizes Axial Flaw Circumferential Flaw (Aspect Ratio = 2) (Aspect Ratio = 10)

Maximum Allowable Initial Flaw Size (a/t)0070.3 Flaw Depth (in) 0.160 0.937 Flaw Length (in) 0.320 9.37 Note: Aspect ratio = flaw length/flaw depth Page 21 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM-1 6-2-NP Revision 0 9.0 References

1. ASME Code Case N-770- 1,Section XI Division 1. "Alternative Examination Requirements and Acceptance Standards for Class 1 PWR Piping and Vessel Nozzle Butt Welds Fabricated with UNS N06082 or UNS W86182 Weld Filler Material With or Without Application of Listed Mitigation Activities." Approval Date December 25, 2009.
2. Letter from Luminant Generation Company LLC to NRC, TXX-15 139, "Comanche Peak Nuclear Power Plant Docket No. 50-445 Revision to Relief Request .1B3-3 for Unit 1 Inservice Inspection for Application of an Alternative to the ASME Boiler and Pressure Vessel Code Section XI Examination Requirements for Reactor Pressure Vessel Cold Leg Weld Inspection Frequency (2007 Edition of ASME Code,Section XI, 2008 Addenda Third Interval Start Date: August 13, 2010 Third Interval End Date: August 12, 2020)," October 15, 2015. (ADAMS Accession Number MLJ5300A 013)
3. ASME Boiler & Pressure Vessel Code, 2007 Edition with 2008 Addenda,Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components."
4. Westinghouse Report WCAP-10 197 Rev. 4, Volume I, "Structural Analysis of the Reactor Coolant* Loop for Comanche Peak Steam Electric Station Units 1 and 2 Analysis of the Primary Coolant Loop Piping," June 2007.
5. Materials Reliability Program: Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 82, 182, and 132 Welds (MRP-1 15), EPRI, Palo Alto, CA: 2004. 1006696.
6. Drawings for RV inlet nozzles:

Comanche Peak Unit 1

a. Combustion Engineering, Inc. Drawing E-10773-121-003, Rev. 01, "Upper Vessel Machining."
b. Combustion Engineering, Inc. Drawing E-10773-121-001, Rev. 03, "Upper Vessel Assembly."

South Texas Unit 1

c. Combustion Engineering, Inc. Drawing, E-1 1073-121-003, Rev. 02, "Upper Vessel Machining."
d. Combustion Engineering, Inc. Drawing, E-1 1073-121-001, Rev. 03, "Upper Vessel Assembly."
7. Dominion Engineering, Inc. Document C-8891-00-01, Rev. 0, "Welding Residual Stress Calculation for South Texas Project Units 1 and 2 RPV Inlet Nozzle DMW," March 2015.
8. Materials Reliability Program: Primary Water Stress Corrosion Cracking (PWSCC) Flaw Evaluation Guidance (MRP-287), EPRI, Palo Alto, CA: 2010, 1021023.
9. Materials Reliability Program: Advanced FEA Evaluation of Growth of Postulated Circumferential PWSCC Flaws in Pressurizer Nozzle Dissimilar Metal Welds (MRP-2 16, Rev. 1): Evaluations Specific to Nine Subject Plants. EPRI, Palo Alto, CA: 2007. 1015400.

Page 22 of 23

Westinghouse Non-Proprietary Class 3 LTR-PAFM- 16-2-NP Revision 0

10. American Petroleum Institute, API 579-1/ASME FFS-1 (API 579 Second Edition), "Fitness-For-Service," June 2007.
11. Combustion Engineering, Inc. Report CENC- 1382, "Addendum 2 to Analytical Report for Comanche Peak Station No. 1 Texas Utilities Services Corporation Reactor Vessel," May 1979.
12. Southern Nuclear Company, Inc. Letter NL-14-1 193, "Joseph M. Farley Nuclear Plant Response to Request for Additional Information Regarding Proposed Alternative to Inservice Inspection Requirements of ASME Code Case N-770-1," Docket Nos. 50-348 and 50-364, Dated August 1, 2014. (ADAMS Accession Number ML14213A484)
13. United States Nuclear Regulatory Commission Letter Dated December 5, 2014, "Joseph M.

Farley, Units 1 and 2, (FNP-ISI-ALT-15, Version 1) Alternative to Inservice Inspection Regarding Reactor Pressure Vessel Cold-Leg Nozzle Dissimilar Metal Welds (TAC Nos. ME 3687 and MF3688)." (ADAMS Accession Number M'L14262A31 7)

14. WesDyne WDI-STD-146, Rev. 9. "ET Examination of Reactor Vessel Pipe Welds Inside Surface," December 2008.
15. United States Nuclear Regulatory Commission Letter Dated August 21, 2015, "South Texas Project, Unit 1 - Request for Relief No. RR-ENG-3-17 for Extension of the Inspection Frequency of the Reactor Vessel Cold-Leg Nozzle to Safe-End Welds with Flaw Analysis (Tac No. MF6 174)." (ADA MS Accession Number ML15218A367)

Page 23 of 23