ML040360651

From kanterella
Jump to navigation Jump to search
Post Irradiation Examination - Assembly GG19, Face 4, 10/20/03
ML040360651
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 10/20/2003
From:
TXU Electric
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML040360651 (1)


Text

Peripheral Oxide Utility:

Comanche Peak 2 Assembly: GG19 Face:

4 Date:

20-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 5.70 11.23 13.56 13.35 13.45 12.80 10.71 5.74 9.91 11.23 11.35 12.62 11.22 9.11 5.78 9.80 10.67 11.32 11.31 10.70 9.29 5.82 10.65 10.57 11.28 11.45 10.59 10.54 5.86 10.71 10.61 11.50 11.30 10.78 11.35 5.90 10.56 9.97 11.20 12.12 11.22 9.89 5.94 10.72 10.63 11.28 12.02 13.34 10.70 5.98 11.25 10.00 12.03 11.35 12.12 10.71 6.02 11.44 10.75 12.64 11.17 11.24 9.79 6.06 12.08 10.57 12.10 11.99 11.44 10.13 6.10 11.90 10.74 11.99 12.15 10.63 9.15 6.14 10.76 9.95 11.37 11.95 10.61 10.70 6.18 10.49 9.97 11.33 12.04 10.50 10.63 6.22 10.69 10.02 11.28 11.85 10.61 12.07 6.26 9.77 10.58 11.45 12.11 10.81 10.66 6.30 10.66 11.38 11.98 12.10 10.50 11.32 6.34 10.06 14.06 12.01 11.97 11.35 12.19 6.38 10.49 10.67 11.40 12.14 11.26 11.23 6.42 11.47 11.45 11.97 11.97 12.03 10.72 6.46 11.25 11.21 12.13 12.09 11.88 9.86 6.50 12.05 11.30 11.95 12.61 11.44 10.68 6.54 11.43 11.19 12.10 12.76 11.41 12.02 6.58 11.26 12.72 12.12 12.14 11.35 10.57 6.62 12.07 12.12 11.98 12.66 11.37 10.74 6.66 11.96 11.24 12.13 12.11 11.19 11.19 6.70 11.37 12.07 12.01 12.62 11.45 11.43 6.74 11.24 11.13 12.12 12.72 11.12 11.23 6.78 11.90 12.02 12.09 12.74 12.75 12.10 6.82 12.13 11.44 11.95 13.40 12.14 11.96 6.86 12.70 11.21 12.11 13.51 14.03 12.09 6.90 13.52 12.03 11.95 13.95 12.76 11.90 6.94 12.64 12.04 12.03 13.51 12.63 12.71 6.98 12.71 11.99 12.12 13.91 12.12 12.73 7.02 12.87 12.85 12.01 14.20 12.58 11.97 7.06 12.65 12.63 12.08 14.95 12.76 12.15 7.10 12.72 12.78 11.89 14.08 12.60 11.92 7.14 12.61 13.34 12.15 14.89 12.77 11.43 7.18 12.73 13.31 12.84 13.97 12.13 11.15 7.22 12.88 13.51 11.96 13.56 11.97 11.32 7.26 12.60 12.63 12.13 13.29 12.84 11.40 7.30 12.13 13.46 11.99 14.78 11.90 10.60 7.34 11.97 13.40 12.09 14.29 12.83 11.45 7.38 11.37 13.36 12.11 14.74 13.33 11.98 7.42 12.12 12.82 11.92 14.88 12.78 12.07

7.46 12.01 13.29 12.10 14.03 12.84 11.27 7.50 12.03 12.03 11.94 13.48 12.66 12.09 7.54 11.95 12.09 12.02 13.52 12.84 11.85 7.58 12.73 12.54 12.11 13.57 12.59 11.38 7.62 12.71 13.50 11.23 13.49 11.95 11.46 7.66 12.73 11.97 12.10 13.26 12.66 12.00 7.70 12.82 12.72 11.98 14.21 12.02 12.14 7.74 12.65 14.21 12.04 13.98 12.09 11.98 7.78 12.69 14.00 12.08 14.07 12.67 12.07 7.82 12.63 12.76 11.31 14.91 14.23 12.63 7.86 13.49 12.61 11.41 14.08 14.09 12.76 7.90 13.50 12.77 11.25 13.48 12.78 13.41 7.94 12.58 12.82 12.01 13.36 13.40 12.73 7.98 12.12 13.36 12.69 13.41 13.41 13.57 8.02 11.94 13.44 12.74 14.00 13.93 11.88 8.06 12.79 14.09 13.55 13.41 14.84 13.53 8.10 13.49 15.60 12.58 13.52 14.91 12.62 8.14 13.39 14.23 12.02 13.31 14.77 12.16 8.18 12.79 14.07 12.61 14.13 13.51 12.57 8.22 13.24 13.49 12.73 13.98 14.05 13.51 8.26 12.66 14.67 12.12 14.17 14.88 14.84 8.30 12.66 14.83 12.55 14.16 14.00 13.99 8.34 12.61 14.23 12.04 14.06 12.70 13.49 8.38 12.03 13.34 11.98 12.79 12.74 13.32 8.42 12.00 14.18 11.94 12.60 12.59 13.51 8.46 12.82 14.01 12.82 12.70 12.85 13.28 8.50 13.33 13.35 11.90 13.40 12.54 13.41 8.54 12.62 13.62 12.08 12.78 12.83 14.21 8.58 12.83 15.38 11.84 13.53 12.71 13.96 8.62 13.35 13.50 12.04 13.29 13.36 14.29 8.66 12.69 13.33 12.16 14.19 12.59 13.34 8.70 12.01 13.37 11.87 13.98 12.60 14.11 8.74 12.65 14.15 12.07 14.13 12.84 12.70 8.78 12.80 14.75 12.60 14.91 14.07 12.77 8.82 12.64 14.17 13.44 14.70 14.17 12.58 8.86 12.75 14.11 12.83 14.81 16.21 13.48 8.90 13.22 14.65 13.31 14.76 12.74 12.84 8.94 13.40 14.20 12.84 14.87 12.58 13.35 8.98 14.23 14.05 12.69 14.06 12.80 14.17 9.02 13.33 14.17 12.80 14.06 12.71 16.86 9.06 14.19 14.94 12.87 14.95 11.99 16.25 9.10 14.01 14.16 12.61 14.71 12.82 12.57 9.14 15.59 14.91 12.80 14.86 12.59 13.46 9.18 14.89 15.43 12.60 13.91 12.75 13.39 9.22 14.01 14.13 12.71 14.88 12.62 12.01 9.26 13.50 14.90 12.78 16.33 12.75 12.15 9.30 13.35 14.72 12.63 17.56 12.79 10.54 9.34 13.47 14.91 12.82 14.90 12.69 11.40 9.38 13.40 14.07 12.65 14.05 12.80 11.27 9.42 13.40 14.81 12.85 14.92 13.34 12.01 9.46 13.49 14.24 13.60 14.05 15.58 11.81 9.50 13.35 15.45 12.59 14.07 13.36 13.46

9.54 13.50 15.54 12.85 14.30 12.76 12.79 9.58 13.51 14.67 12.70 14.70 13.26 11.87 9.62 13.35 15.49 12.78 14.87 13.44 12.14 9.66 13.46 14.22 12.17 14.75 12.86 11.96 9.70 15.50 14.75 11.98 14.80 13.32 12.07 9.74 14.84 14.78 12.73 14.18 14.23 11.89 9.78 14.06 13.97 12.64 13.96 14.03 12.09 9.82 14.79 14.77 12.75 14.17 14.80 12.60 9.86 14.19 16.34 12.88 13.99 14.03 12.71 9.90 13.96 17.50 13.33 14.11 14.15 13.57 9.94 13.48 14.83 12.79 14.75 14.24 12.62 9.98 14.06 14.87 12.55 14.87 14.68 13.56 10.02 14.12 13.99 13.45 14.95 15.56 13.31 10.06 14.25 14.19 13.48 14.66 14.72 14.20 10.10 14.04 13.36 13.26 14.27 18.41 15.35 10.14 14.21 14.12 13.52 14.66 20.30 14.20 10.18 13.94 14.19 14.03 15.62 13.50 14.21 10.22 14.13 14.08 13.40 15.35 13.44 14.15 10.26 14.31 14.81 13.56 14.23 14.06 12.86 10.30 13.32 14.00 13.31 14.19 13.52 13.32 10.34 14.15 14.87 13.48 14.04 13.38 12.78 10.38 14.71 15.65 13.41 14.11 14.24 13.37 10.42 14.82 17.55 14.16 15.45 14.03 14.22 10.46 14.96 19.84 14.19 14.09 14.10 14.74 10.50 15.39 14.72 14.01 14.80 14.03 15.50 10.54 15.62 15.48 14.89 14.15 13.40 16.31 10.58 14.06 15.62 15.39 14.95 13.52 15.41 10.62 14.82 14.71 14.17 15.37 14.04 15.64 10.66 14.25 14.82 14.23 17.66 13.50 13.32 10.70 14.07 16.02 14.07 15.41 14.01 12.73 10.74 13.51 16.11 14.16 14.79 14.20 11.87 10.78 13.37 14.91 14.72 14.92 14.03 12.73 10.82 13.46 15.39 14.90 15.52 13.35 13.38 10.86 14.24 16.19 14.90 15.64 12.57 13.44 10.90 14.64 16.11 14.70 15.37 12.69 12.83 10.94 14.22 16.21 15.59 15.48 12.86 13.27 10.98 14.09 16.38 15.45 15.37 13.32 14.17 11.02 13.47 16.13 15.60 16.22 13.49 14.10 11.06 13.48 16.18 15.50 15.57 12.66 14.29 11.10 14.13 15.48 14.81 17.55 13.41 14.71 11.14 14.94 15.53 14.92 15.66 13.31 15.48 11.18 14.07 15.61 14.67 15.45 14.19 12.19 11.22 14.08 15.41 13.39 16.28 15.52 11.34 11.26 13.45 15.60 13.35 16.18 14.00 12.13 11.30 13.39 17.55 14.07 16.15 14.20 11.90 11.34 13.52 15.51 14.90 15.66 13.32 12.08 11.38 13.27 15.60 14.00 15.42 13.55 11.92 11.42 13.38 15.43 14.20 16.30 14.03 12.11 11.46 14.07 16.28 14.08 15.43 13.46 12.75 11.50 14.00 16.31 14.76 14.89 13.47 12.64 11.54 14.24 15.48 14.93 14.88 14.15 12.84 11.58 14.79 14.88 14.81 14.70 14.25 12.69

11.62 14.15 15.38 14.86 15.60 13.31 14.87 11.66 14.23 15.56 15.47 14.81 12.80 13.35 11.70 14.07 15.70 15.62 14.81 11.88 14.24 11.74 14.24 14.74 15.53 14.64 12.77 14.69 11.78 13.38 14.86 14.66 17.62 12.57 16.97 11.82 13.44 15.35 14.94 15.54 12.76 16.98 11.86 13.53 15.45 14.77 16.20 14.12 16.79 11.90 13.24 15.61 14.15 14.87 14.16 14.98 11.94 13.53 15.41 14.12 16.87 14.24 18.21 11.98 13.36 15.51 14.76 14.90 14.75 18.39 12.02 13.43 16.87 15.61 13.99 14.15 14.00 12.06 14.13 16.22 15.50 14.05 13.38 14.11 12.10 14.00 17.01 14.89 16.36 13.46 14.08 12.14 14.27 15.37 15.52 16.11 13.41 14.79 12.18 14.07 15.61 14.82 16.27 13.36 15.63 12.22 14.09 15.42 14.22 16.20 12.84 14.09 12.26 14.75 14.81 14.09 16.19 12.66 14.20 12.30 14.86 14.91 14.86 16.21 13.46 15.31 12.34 14.20 15.30 15.47 16.19 13.29 17.68 12.38 14.89 15.68 14.07 14.92 14.28 13.91 12.42 15.43 15.43 14.88 13.96 14.04 14.17 12.46 14.70 15.54 14.78 14.90 14.13 14.84 12.50 14.88 15.65 15.48 15.46 14.16 14.10 12.54 14.94 16.77 15.43 15.59 14.06 14.25 12.58 14.70 16.90 16.28 14.91 15.61 13.34 12.62 14.91 18.41 15.65 14.77 15.43 14.12 12.66 14.04 16.81 15.29 15.58 14.90 14.76 12.70 14.89 16.30 15.65 15.37 14.66 14.89 12.74 15.64 16.20 16.04 14.81 14.13 14.65 12.78 15.38 15.56 16.23 14.68 14.90 14.90 12.82 15.53 15.59 17.10 16.27 14.07 15.64 12.86 16.10 17.57 17.50 16.39 14.21 15.36 12.90 15.51 14.91 18.39 14.70 15.43 15.60 12.94 15.65 14.04 16.78 15.57 16.27 15.40 12.98 16.85 15.47 16.19 15.41 13.36 14.84 13.02 17.65 16.15 17.06 15.57 14.12 15.46 13.06 17.54 16.23 16.78 16.16 14.79 16.88 13.10 16.21 14.93 16.26 16.29 14.81 16.90 13.14 16.38 14.71 15.36 15.60 14.95 16.95 13.18 16.19 14.89 15.47 16.03 14.70 17.79 13.22 16.30 16.19 16.38 16.25 14.90 22.47 13.26 16.14 15.52 16.11 17.56 14.70 26.33 13.30 14.87 15.65 16.31 19.10 14.81 17.49 13.34 14.87 15.37 14.70 15.57 14.67 16.29 13.38 14.74 15.58 14.83 15.50 14.17 16.07 13.42 14.18 16.19 15.69 15.60 14.95 15.54 13.46 14.05 15.40 15.40 14.65 14.03 15.62 13.50 15.58 15.64 14.88 15.62 14.90 14.69 13.54 14.84 15.49 13.99 14.68 14.67 14.23 13.58 14.79 15.48 15.57 15.50 14.83 15.39 13.62 15.57 16.32 16.31 15.61 14.71 14.16 13.66 14.76 16.90 16.17 15.38 14.13 14.00

13.70 14.84 19.07 15.61 16.29 13.39 14.15 13.74 14.77 17.53 15.42 16.82 14.08 15.51 13.78 14.69 17.68 16.22 15.54 14.93 15.47 13.82 14.90 17.78 15.52 14.76 14.76 14.83 13.86 14.72 18.93 14.78 14.82 14.88 14.82 13.90 15.62 17.66 14.90 14.92 14.71 14.96 13.94 15.39 16.08 14.09 14.75 16.25 16.13 13.98 14.87 16.86 14.84 16.27 14.69 12.76 14.02 15.61 17.78 14.84 16.05 14.83 13.45 14.06 15.38 16.15 16.05 15.60 14.90 13.45 14.10 16.97 15.53 16.37 15.59 14.67 14.78 14.14 18.19 16.16 16.87 16.06 15.60 15.42 14.18 16.99 17.68 17.60 17.07 14.65 14.29 14.22 14.96 17.74 14.70 14.70 14.93 13.32 14.26 13.40 16.87 14.75 15.51 15.39 14.88 14.30 13.38 16.95 14.91 15.31 14.87 16.95 14.34 13.99 16.82 15.39 15.53 14.72 19.82 14.38 15.54 17.53 16.28 15.74 14.84 14.65 14.42 15.65 18.38 16.14 15.40 15.61 15.54 14.46 16.85 19.02 16.23 17.03 16.82 15.58 14.50 16.26 16.31 17.04 16.87 15.61 15.41 14.54 16.21 16.98 18.25 16.23 14.72 15.58 14.58 16.98 16.95 20.51 16.15 14.88 15.38 14.62 16.33 18.46 19.02 15.40 15.34 17.71 14.66 15.46 18.36 17.59 15.65 16.97 16.82 14.70 15.56 18.37 17.00 16.14 15.57 17.05 14.74 16.84 17.63 16.78 16.22 16.21 17.55 14.78 16.99 16.88 17.71 16.77 15.61 15.48 14.82 17.00 17.68 16.89 16.98 14.70 15.64 14.86 16.83 17.53 16.19 16.99 14.84 14.07 14.90 17.01 19.12 16.31 16.10 14.71 14.24 14.94 16.82 17.74 17.63 17.07 14.99 14.68 14.98 16.96 17.53 17.72 16.11 15.45 14.82 15.02 16.99 16.97 17.53 16.21 14.78 14.71 15.06 16.19 18.16 17.68 16.16 14.29 14.86 15.10 17.05 17.63 16.90 16.27 14.00 15.53 15.14 16.86 17.03 16.10 17.01 14.91 14.18 15.18 17.74 16.82 17.03 16.85 15.42 13.56 15.22 17.51 16.95 17.49 17.00 17.73 14.01 15.26 16.94 16.13 17.68 16.86 17.50 12.77 15.30 16.99 16.89 16.74 16.20 17.61 12.72 15.34 16.04 17.73 16.18 17.01 17.03 13.46 15.38 16.26 16.08 16.31 16.84 16.14 13.27 15.42 17.53 16.98 15.47 16.96 16.29 13.40 15.46 16.95 16.94 15.53 16.14 17.52 13.59 15.50 17.78 16.92 15.41 17.63 17.03 14.63 15.54 16.77 17.07 14.81 16.86 16.11 14.15 15.58 16.93 18.24 15.62 16.25 15.47 13.99 15.62 16.00 19.81 16.17 15.63 15.56 14.24 15.66 15.56 16.17 15.61 16.18 14.86 14.66 15.70 16.32 16.16 16.13 16.27 18.47 15.57 15.74 16.75 15.60 15.50 16.85 18.25 16.13

15.78 17.68 16.19 15.56 16.26 17.05 15.58 15.82 15.38 17.65 16.16 16.23 16.84 15.63 15.86 15.61 19.06 16.30 16.17 16.27 14.05 15.90 16.36 16.13 16.08 17.03 18.31 13.57 15.94 15.42 16.95 15.61 16.08 14.15 14.63 15.98 15.58 17.57 14.83 16.25 14.25 14.16 16.02 15.35 18.33 15.54 16.05 13.33 13.36 16.06 16.30 18.42 15.59 16.95 16.30 14.17 16.10 16.31 16.85 16.13 16.38 15.51 13.37 16.14 15.39 16.23 16.34 16.13 14.17 13.38 16.18 15.62 15.51 16.17 16.31 13.92 13.56 16.22 15.43 15.53 14.81 16.17 14.86 14.05 16.26 16.21 15.54 15.56 16.92 16.90 14.20 16.30 15.59 15.45 15.45 16.82 16.03 14.05 16.34 16.16 14.91 14.91 17.51 14.96 13.49 16.38 15.61 15.34 15.45 17.73 14.72 14.66 16.42 15.46 16.22 16.17 18.24 14.83 16.27 16.46 14.87 19.88 15.63 15.54 13.40 17.76 16.50 15.62 19.63 15.38 16.09 14.09 15.42 16.54 16.10 17.03 15.62 16.22 14.79 14.21 16.58 17.03 16.03 15.37 17.04 14.80 15.45 16.62 14.74 15.59 16.18 17.49 14.93 14.90 16.66 15.57 16.37 15.01 17.03 15.49 13.99 16.70 16.28 14.72 15.46 17.52 16.26 14.81 16.74 16.20 15.53 15.51 17.60 17.60 15.40 16.78 16.31 16.14 14.71 15.49 18.43 16.99 16.82 17.63 18.25 14.91 16.11 16.76 16.29 16.86 16.21 19.15 14.96 17.03 14.91 16.19 16.90 15.36 16.85 14.72 18.18 14.89 16.30 16.94 16.23 16.31 16.25 18.36 14.82 14.76 16.98 14.98 17.70 16.18 18.22 15.65 15.54 17.02 15.36 17.50 15.54 18.35 16.84 14.70 17.06 14.89 16.27 16.31 19.16 15.61 16.25 17.10 15.31 15.46 16.86 17.59 15.49 13.53 17.14 15.56 14.80 16.96 16.95 14.86 13.94 17.18 15.63 15.68 16.83 16.88 15.38 14.25 17.22 16.77 16.15 17.73 17.61 15.50 13.28 17.26 17.04 16.95 18.36 18.92 16.26 13.48 17.30 16.77 16.21 18.29 17.61 15.45 13.38 17.34 16.94 15.50 18.42 17.73 14.90 12.75 17.38 17.06 16.32 18.81 18.27 14.69 12.61 17.42 16.79 16.79 17.61 19.85 14.17 13.40 17.46 17.71 16.16 18.20 18.27 14.71 14.98 17.50 16.06 14.88 17.50 18.39 16.95 16.14 17.54 16.29 15.41 17.78 19.08 16.15 15.59 17.58 15.61 15.62 18.21 18.93 18.33 16.09 17.62 14.75 16.85 17.60 21.30 21.33 16.95 17.66 15.62 17.72 18.22 19.65 20.40 16.77 17.70 15.48 17.64 18.36 17.75 15.59 16.95 17.74 16.25 16.05 18.51 18.14 16.89 15.63 17.78 16.34 16.99 17.57 19.05 17.63 15.41 17.82 16.17 16.87 18.41 19.14 16.74 16.28

17.86 15.60 17.56 18.25 18.29 15.54 16.88 17.90 15.41 16.97 17.68 17.71 16.34 17.64 17.94 16.27 16.82 17.04 17.61 16.86 13.95 17.98 15.46 16.98 16.16 18.36 15.60 14.19 18.02 15.46 15.50 16.27 18.28 16.13 14.15 18.06 15.54 15.54 16.14 18.26 16.34 16.89 18.10 15.38 16.32 16.22 18.48 16.75 18.47 18.14 15.53 16.13 16.37 17.55 17.72 16.18 18.18 15.36 16.27 16.84 19.11 17.65 14.88 18.22 14.88 17.48 16.96 19.60 17.54 14.71 18.26 14.95 16.84 17.57 19.06 16.34 15.58 18.30 14.67 17.73 17.64 19.78 15.35 15.47 18.34 15.54 18.20 17.06 18.22 15.63 16.88 18.38 15.38 16.98 16.88 17.78 16.18 20.57 18.42 16.16 16.79 17.00 18.28 14.13 19.65 18.46 17.03 16.96 15.40 17.65 14.70 16.30 18.50 16.79 17.79 16.90 18.31 18.41 13.29 18.54 16.93 16.85 16.18 16.97 18.47 14.15 18.58 16.75 15.64 16.13 17.00 18.16 14.12 18.62 16.11 15.46 18.40 17.57 19.13 15.58 18.66 15.64 16.22 14.68 18.41 17.52 17.57 18.70 16.86 17.66 14.89 18.95 16.23 16.20 18.74 17.62 16.83 14.69 19.76 16.84 15.68 18.78 16.81 17.70 16.82 19.64 17.72 15.51 18.82 16.14 18.48 16.38 18.35 14.88 16.98 18.86 15.65 20.24 15.42 18.39 16.81 16.17 18.90 16.13 19.87 15.50 19.60 16.29 14.91 18.94 16.25 18.33 16.05 19.21 16.85 15.37 18.98 16.84 17.61 17.00 18.29 16.99 14.17 19.02 17.63 17.01 16.29 18.35 16.90 14.90 19.06 15.65 16.90 15.43 18.19 18.33 13.25 19.10 14.79 16.92 15.59 18.97 18.90 13.56 19.14 15.58 17.48 15.42 19.16 17.65 14.03 19.18 15.41 16.93 16.22 18.30 16.30 15.56 19.22 15.53 19.92 17.71 18.38 16.05 14.75 19.26 15.63 16.14 16.93 18.28 14.92 15.54 19.30 16.06 16.90 16.30 19.84 14.59 15.39 19.34 17.03 18.36 15.43 19.71 16.27 15.58 19.38 16.90 18.27 15.56 19.75 16.86 18.46 19.42 16.31 16.30 15.53 20.59 17.67 17.61 19.46 15.61 16.85 15.47 20.29 18.26 14.92 19.50 15.43 17.67 16.31 20.48 17.68 16.82 19.54 15.60 18.46 16.14 20.31 17.00 17.61 19.58 15.42 20.40 16.96 20.44 18.25 19.69 19.62 17.71 21.21 16.98 19.90 19.08 19.05 19.66 16.28 18.94 15.50 19.61 18.27 17.62 19.70 16.81 18.33 16.36 21.31 18.42 17.64 19.74 17.03 17.03 16.15 21.69 19.61 17.07 19.78 16.13 17.55 16.99 21.94 16.94 15.39 19.82 16.23 18.33 16.26 21.75 16.98 19.79 19.86 16.11 17.55 16.13 21.85 17.50 21.08 19.90 16.14 20.50 17.73 21.97 18.49 15.66

19.94 17.00 22.63 17.54 22.46 17.55 16.05 19.98 17.55 23.14 19.87 23.35 17.70 16.26 20.02 16.16 19.82 18.87 22.52 18.18 16.33 20.06 16.06 18.16 18.33 23.35 17.72 16.17 20.10 15.61 16.94 18.44 21.83 17.46 16.36 20.14 15.62 16.27 18.29 21.79 17.66 16.20 20.18 16.10 16.87 18.36 20.53 17.63 14.84 20.22 15.52 16.95 17.44 21.09 17.62 15.47 20.26 16.17 18.14 17.66 21.86 17.01 16.93 20.30 16.82 18.33 18.41 22.43 18.18 16.06 20.34 17.01 17.77 18.97 21.77 20.55 16.21 20.38 16.85 17.48 18.43 21.99 21.66 17.72 20.42 16.94 18.30 17.46 21.06 21.87 18.93 20.46 16.72 20.50 17.03 21.24 21.89 19.22 20.50 16.94 22.55 17.00 20.33 21.79 17.44 20.54 17.05 21.24 16.84 20.50 22.70 17.66 20.58 17.44 18.85 17.73 20.52 21.72 18.97 20.62 16.95 18.40 16.84 20.39 21.19 19.08 20.66 17.52 18.30 16.30 19.87 23.26 18.29 20.70 16.83 19.02 16.29 19.71 24.74 18.39 20.74 17.75 19.18 16.11 19.77 23.14 17.70 20.78 17.52 18.33 15.60 19.72 21.24 17.55 20.82 17.67 19.01 16.11 19.02 19.15 17.68 20.86 18.12 19.69 16.92 19.14 18.90 19.69 20.90 18.38 19.75 16.15 18.22 19.81 21.22 20.94 17.73 18.42 16.14 18.40 18.20 18.15 20.98 17.51 18.31 16.38 17.45 18.35 18.33 21.02 18.32 18.31 16.11 18.40 17.53 17.59 21.06 18.17 18.36 16.21 19.18 18.43 16.90 21.10 19.12 18.98 16.84 19.04 19.02 15.63 21.14 18.47 19.85 16.85 19.08 19.02 14.77 21.18 16.84 18.90 15.63 18.32 17.75 15.59 21.22 17.01 19.08 14.78 19.04 16.17 14.72 21.26 16.82 19.12 14.90 18.90 15.61 15.60 21.30 16.32 20.39 15.40 18.41 16.11 17.51 21.34 16.36 16.96 15.45 18.46 18.35 15.59 21.38 16.85 16.82 14.96 18.85 18.18 16.22 21.42 16.89 17.61 14.67 19.10 16.94 17.45 21.46 16.81 17.75 14.80 18.21 16.26 19.87 21.50 16.99 17.56 15.35 18.39 16.78 17.49 21.54 16.29 17.00 16.25 18.95 17.74 15.59 21.58 15.47 17.52 17.03 19.04 16.81 15.52 21.62 15.58 19.04 16.17 18.46 17.71 14.78 21.66 15.41 22.71 16.27 18.25 17.61 16.11 21.70 16.96 18.92 16.08 17.68 21.12 16.18 21.74 17.04 18.39 15.43 17.46 19.64 16.25 21.78 15.43 18.91 15.61 17.64 16.21 15.35 21.82 16.27 17.54 16.82 18.43 16.36 15.62 21.86 16.06 16.34 16.31 18.97 16.82 15.41 21.90 16.23 17.51 15.45 19.11 18.42 17.68 21.94 15.62 19.04 16.97 17.56 18.22 16.78 21.98 15.42 16.77 16.31 17.73 17.67 17.62

22.02 16.30 19.14 16.19 17.60 18.93 14.81 22.06 16.15 19.16 16.27 19.10 21.14 14.81 22.10 16.28 16.82 15.48 19.16 19.10 14.96 22.14 17.04 16.96 16.16 18.18 16.10 15.45 22.18 15.50 17.60 16.32 18.44 17.81 17.04 22.22 15.56 16.90 15.52 17.50 18.22 18.96 22.26 15.41 16.98 16.33 18.27 19.08 16.95 22.30 15.54 17.53 15.31 18.40 18.89 14.66 22.34 15.60 18.41 15.58 17.52 19.06 14.84 22.38 15.45 18.36 16.30 18.42 18.22 15.52 22.42 15.66 18.28 16.82 17.48 18.27 16.92 22.46 15.51 19.11 16.30 18.42 16.32 17.01 22.50 16.30 19.74 16.16 18.97 16.20 16.03 22.54 16.89 20.41 15.59 18.28 16.28 17.72 22.58 16.83 19.85 15.45 18.50 16.07 16.89 22.62 17.04 18.22 16.26 18.28 15.63 17.04 22.66 16.17 18.43 17.05 19.07 16.08 17.70 22.70 16.95 18.21 16.79 18.98 16.25 17.73 22.74 16.22 18.36 16.96 18.42 16.28 18.44 22.78 16.81 19.87 17.42 17.71 16.89 18.92 22.82 16.29 19.69 17.01 16.88 17.01 18.46 22.86 16.11 18.41 17.07 17.67 17.51 20.40 22.90 16.31 18.98 16.13 17.52 15.50 20.29 29.25 14.63 15.97 18.63 19.89 18.52 21.93 29.29 14.59 15.17 16.46 18.59 18.42 20.35 29.33 14.65 14.63 15.99 18.53 19.22 18.59 29.37 15.13 15.12 16.53 18.64 17.14 18.60 29.41 15.29 15.31 17.22 17.80 17.21 18.45 29.45 15.80 15.80 16.46 18.63 17.10 18.62 29.49 15.38 16.61 17.35 19.63 17.28 17.78 29.53 18.56 15.82 18.41 19.94 17.92 18.63 29.57 15.20 16.66 18.47 18.48 18.47 18.41 29.61 14.64 15.79 18.34 18.55 17.99 19.19 29.65 15.81 15.99 17.24 19.05 18.40 18.47 29.69 15.29 16.49 15.74 19.22 23.93 18.43 29.73 14.58 15.97 17.22 19.71 24.33 19.29 29.77 14.67 15.80 16.46 19.87 16.58 20.42 29.81 14.52 16.67 15.97 19.87 17.14 17.90 29.85 14.72 16.54 16.51 19.74 16.58 17.82 29.89 14.53 15.33 17.29 19.31 16.49 19.14 29.93 16.02 15.18 16.62 19.73 16.53 21.08 29.97 15.90 15.37 17.24 19.94 17.33 17.87 30.01 20.59 16.43 18.55 19.74 18.47 18.62 30.05 17.14 15.37 17.87 19.23 19.28 17.78 30.09 18.45 16.40 17.32 19.09 19.04 17.94 30.13 17.94 17.27 17.10 19.23 19.15 17.11 30.17 18.36 17.83 17.93 19.68 18.59 16.52 30.21 15.91 16.53 17.11 19.26 18.52 17.04 30.25 15.18 15.91 17.26 19.78 17.11 17.28 30.29 15.29 15.96 16.47 19.17 17.90 16.64 30.33 15.19 16.59 17.32 18.63 17.95 17.83 30.37 15.95 15.98 17.80 18.41 17.76 18.56

30.41 16.51 17.25 18.54 19.34 19.15 18.45 30.45 17.91 17.89 17.77 18.50 20.38 18.51 30.49 16.38 17.16 17.26 19.27 20.61 18.33 30.53 15.34 17.17 18.43 19.14 18.48 19.24 30.57 15.91 18.56 19.20 19.91 18.11 19.26 30.61 16.37 19.78 19.14 19.00 17.74 19.73 30.65 15.90 18.56 19.25 19.26 17.87 22.64 30.69 16.46 17.78 19.76 19.09 17.80 15.85 30.73 17.24 18.59 19.18 19.25 18.52 16.54 30.77 18.37 17.11 19.08 19.67 19.30 16.47 30.81 18.56 17.89 17.89 19.85 19.13 17.17 30.85 16.55 19.03 18.36 19.73 19.24 17.78 30.89 16.03 17.85 19.24 19.87 18.42 17.14 30.93 15.78 17.73 18.42 19.94 18.61 17.31 30.97 15.42 17.21 18.49 20.50 18.42 17.76 31.01 15.90 17.09 18.51 20.59 19.30 18.64 31.05 16.51 17.84 17.79 21.12 19.05 19.06 31.09 17.28 17.12 18.58 21.28 19.85 19.17 31.13 17.04 17.99 19.17 21.12 18.55 18.44 31.17 17.94 17.80 18.64 21.21 18.41 17.88 31.21 17.15 17.83 19.15 21.10 19.31 18.64 31.25 15.95 17.19 19.92 21.19 19.72 18.43 31.29 15.84 17.22 19.76 20.97 20.51 18.54 31.33 15.95 17.82 19.28 20.49 21.09 17.76 31.37 16.56 18.59 20.42 21.17 21.89 19.21 31.41 17.33 17.82 19.95 21.87 27.88 17.06 31.45 17.16 17.89 19.08 21.23 25.88 17.22 31.49 17.14 17.73 18.54 21.04 23.03 17.89 31.53 17.22 17.95 17.73 21.30 23.85 18.57 31.57 17.10 17.13 17.89 20.41 21.94 17.28 31.61 15.91 17.88 17.81 21.31 21.22 17.74 31.65 15.82 19.09 18.64 20.40 21.28 17.31 31.69 15.34 18.60 19.05 20.61 20.45 17.16 31.73 17.12 18.47 18.49 19.72 21.27 17.83 31.77 17.93 17.95 18.39 19.83 25.07 17.76 31.81 17.14 18.37 18.57 19.87 24.58 17.88 31.85 16.64 18.61 18.41 20.58 22.44 17.30 31.89 16.50 21.12 18.52 20.40 22.56 16.46 31.93 16.62 21.25 19.12 19.90 21.71 16.68 31.97 16.63 18.50 18.55 20.49 21.24 16.47 32.01 16.41 18.60 19.18 19.81 18.56 17.31 32.05 16.61 18.49 19.94 20.59 19.14 18.34 32.09 17.15 19.20 21.29 20.48 19.27 17.92 32.13 17.24 18.60 20.48 20.61 19.82 19.73 32.17 17.75 19.10 19.96 20.41 19.93 21.19 32.21 18.59 19.23 19.70 19.96 19.10 21.26 32.25 19.07 19.13 19.92 20.42 19.22 19.10 32.29 18.62 19.86 19.85 20.54 19.22 19.88 32.33 17.84 17.79 19.95 20.42 19.25 18.48 32.37 15.32 18.59 19.76 19.87 19.69 18.55 32.41 15.29 18.41 20.01 19.73 19.21 18.40 32.45 15.09 20.48 19.75 20.48 19.15 18.56

32.49 15.96 18.41 21.29 20.35 19.21 17.97 32.53 18.39 19.31 20.42 20.53 18.60 17.88 32.57 17.85 18.47 20.57 21.13 18.47 19.91 32.61 17.80 19.26 21.00 21.84 18.67 22.39 32.65 15.99 19.13 21.19 22.59 18.39 19.29 32.69 15.17 17.21 19.77 22.49 19.22 19.06 32.73 15.33 17.82 19.20 22.56 19.82 19.15 32.77 15.81 17.92 21.04 21.10 19.83 17.72 32.81 16.68 19.06 21.21 21.31 19.02 17.90 32.85 15.88 19.19 21.07 20.40 19.86 17.91 32.89 15.92 19.00 20.55 21.20 18.59 17.72 32.93 16.60 19.93 19.71 21.16 18.37 17.31 32.97 16.48 19.83 21.19 22.46 19.28 17.00 33.01 15.99 21.29 21.15 23.06 19.13 17.80 33.05 15.83 19.75 21.24 23.21 19.27 18.43 33.09 15.38 19.95 21.15 21.17 19.05 19.18 33.13 15.23 20.39 19.85 21.80 19.24 19.81 33.17 15.33 21.26 20.57 21.85 19.05 19.85 33.21 15.86 21.75 21.04 21.05 19.80 19.27 33.25 16.06 20.64 21.87 21.33 18.34 18.49 33.29 15.24 20.46 21.75 21.08 18.53 18.61 33.33 15.96 20.61 21.91 21.26 18.55 18.51 33.37 15.91 19.89 21.17 21.10 19.02 19.26 33.41 16.41 19.95 21.26 21.92 19.93 19.09 33.45 16.50 19.78 21.81 21.72 19.75 19.88 33.49 15.87 19.92 23.96 20.61 20.60 19.85 33.53 15.94 19.91 22.32 20.43 21.69 21.10 33.57 16.43 21.77 20.65 21.27 25.22 19.94 33.61 17.29 23.19 19.76 21.04 21.15 18.49 33.65 16.47 20.50 19.97 21.93 19.75 18.66 33.69 16.66 21.81 20.44 21.94 19.71 18.44 33.73 17.19 22.34 19.94 21.20 20.58 18.52 33.77 17.17 21.89 19.73 21.27 19.83 18.44 33.81 17.28 23.66 20.61 21.09 19.88 19.26 33.85 16.41 21.16 21.07 21.31 19.97 19.32 33.89 16.57 21.65 22.56 21.78 21.08 19.06 33.93 17.21 21.96 22.44 21.94 24.59 21.30 33.97 17.24 21.74 23.19 21.70 21.02 21.09 34.01 17.12 21.19 19.85 21.84 21.16 19.81 34.05 17.32 20.50 19.83 21.73 20.44 19.74 34.09 16.50 21.21 18.44 21.93 19.84 19.87 34.13 16.61 23.02 18.64 21.08 19.74 19.19 34.17 16.52 21.28 19.05 21.21 19.19 17.86 34.21 15.81 20.40 19.29 21.10 18.60 18.61 34.25 17.20 19.92 19.80 21.23 19.17 18.45 34.29 17.04 21.08 19.15 21.12 19.34 19.23 34.33 17.89 21.26 19.06 21.12 19.72 18.48 34.37 17.16 20.42 18.57 21.28 19.95 18.49 34.41 16.00 20.60 19.06 21.71 19.75 18.38 34.45 16.46 18.40 19.21 21.30 20.57 19.23 34.49 16.67 19.29 19.13 21.71 19.77 18.63 34.53 16.49 19.82 19.89 20.60 19.82 17.73

34.57 17.33 19.87 19.17 20.37 19.75 18.62 34.61 17.25 18.41 18.48 20.59 18.56 18.99 34.65 16.47 19.97 18.58 19.81 19.26 19.20 34.69 16.57 19.84 19.18 20.60 18.47 19.65 34.73 17.09 19.94 17.98 21.08 19.26 21.88 34.77 17.91 19.82 18.43 20.61 19.04 21.12 34.81 17.11 20.64 18.00 20.41 19.24 20.49 34.85 17.27 20.53 17.26 19.84 19.09 19.22 34.89 17.79 19.04 17.99 19.92 19.19 18.39 34.93 17.33 19.29 19.06 19.87 19.66 18.54 34.97 16.49 19.06 19.92 19.96 19.82 17.78 35.01 16.59 19.23 19.80 19.72 18.49 18.52 35.05 16.59 19.06 19.22 21.29 18.52 18.40 35.09 16.43 19.26 19.12 20.43 19.30 18.54 35.13 16.58 19.12 19.25 20.53 19.80 19.18 35.17 17.15 19.18 19.71 20.41 19.92 19.76 35.21 17.26 19.74 21.89 20.51 19.74 21.32 35.25 17.74 20.55 19.81 20.44 19.94 22.41 35.29 18.62 19.09 19.91 21.22 20.45 19.92 35.33 19.78 19.21 18.50 21.12 21.88 19.78 35.37 21.29 19.72 18.56 21.13 18.37 19.26 35.41 20.52 19.24 17.70 20.56 19.33 19.77 35.45 20.52 19.83 18.47 19.85 19.78 17.83 35.49 18.56 19.23 18.38 20.68 20.47 17.30 35.53 17.73 19.14 17.94 19.77 20.60 17.13 35.57 17.16 19.21 19.06 19.89 20.47 17.93 35.61 18.45 19.08 18.63 21.13 20.61 17.80 35.65 17.94 18.57 19.04 21.93 21.76 17.94 35.69 18.42 19.09 19.82 21.03 21.88 18.34 35.73 19.91 19.25 19.71 21.18 19.09 19.23 35.77 19.78 19.72 19.81 20.44 19.19 18.54 35.81 17.30 19.31 19.84 21.13 18.39 19.06 35.85 17.84 19.07 18.51 21.03 19.18 20.61 35.89 17.14 19.23 18.61 21.13 19.20 22.40 35.93 16.58 19.73 19.85 21.15 19.17 19.87 35.97 17.07 20.56 20.62 21.15 18.63 18.40 36.01 17.86 20.45 19.87 21.29 19.11 18.58 36.05 19.85 19.28 19.22 21.17 19.96 19.14 36.09 19.23 19.75 19.20 21.31 20.47 19.19 36.13 19.08 19.29 18.63 20.42 20.56 19.33 36.17 17.36 20.49 19.81 19.98 19.76 19.04 36.21 17.13 22.00 20.66 19.74 20.49 19.26 36.25 17.87 21.10 19.87 21.23 20.38 18.43 36.29 18.52 21.30 19.95 21.72 20.56 19.21 36.33 18.35 21.87 20.41 22.48 20.48 19.19 36.37 18.52 21.28 20.64 21.75 20.41 19.13 36.41 17.75 21.74 20.38 21.81 19.30 19.32 36.45 17.93 21.29 20.67 21.65 19.12 19.76 36.49 17.11 21.12 20.47 21.25 19.98 20.59 36.53 18.64 22.49 21.25 21.18 19.75 19.71 36.57 18.49 21.85 21.10 21.20 20.53 20.50 36.61 19.30 21.76 21.92 21.93 21.10 22.41

36.65 17.86 21.88 21.69 21.69 21.31 20.51 36.69 17.11 23.10 21.88 21.24 21.03 20.57 36.73 17.34 23.21 22.47 21.75 20.52 20.45 36.77 17.14 21.70 21.83 21.90 19.17 20.62 36.81 17.31 21.23 20.48 21.67 18.43 27.73 36.85 17.84 21.00 21.19 21.26 19.27 26.64 36.89 17.86 20.58 21.73 21.77 19.73 22.47 36.93 18.44 21.06 21.90 21.91 19.90 21.93 36.97 19.27 22.48 21.08 21.03 20.38 19.68 37.01 21.08 21.71 21.27 22.58 20.54 19.88 37.05 18.59 20.50 21.05 22.37 19.73 19.95 37.09 17.15 20.48 21.23 21.22 19.84 19.12 37.13 18.45 19.92 21.08 20.57 19.65 18.59 37.17 17.99 19.76 21.19 20.46 21.23 18.42 37.21 18.38 19.83 20.35 21.24 21.83 18.61 37.25 19.85 20.35 19.87 21.70 19.85 17.76 37.29 19.01 20.64 19.12 20.59 19.99 17.85 37.33 17.91 19.80 17.90 21.11 20.41 18.37 37.37 18.42 19.94 19.17 21.25 24.61 18.57 37.41 19.31 19.69 19.87 21.12 25.06 19.14 37.45 18.41 20.60 20.41 21.75 21.84 19.71 37.49 18.65 19.78 19.21 21.78 22.42 20.58 37.53 17.86 19.94 19.82 21.83 21.82 20.39 37.57 17.72 18.97 19.14 21.73 20.27 19.89 37.61 19.23 20.61 19.11 21.84 21.19 21.06 37.65 19.77 19.83 19.90 21.07 20.53 23.16 37.69 19.23 19.26 18.63 21.22 21.01 19.05 37.73 19.04 19.84 19.15 21.88 21.28 19.26 37.77 20.58 19.93 19.30 21.82 21.72 19.28 37.81 19.10 19.75 19.08 21.24 21.31 19.80 37.85 18.63 19.89 18.65 21.08 20.33 19.28 37.89 19.86 19.23 18.47 21.96 19.86 18.42 37.93 17.86 19.86 18.64 21.03 19.81 18.51 37.97 17.89 19.90 19.72 21.26 19.78 19.06 38.01 18.52 19.81 20.64 21.11 19.76 19.27 38.05 19.25 19.20 19.78 21.87 19.78 19.23 38.09 21.75 18.41 19.96 21.74 20.58 19.15 38.13 19.97 19.28 19.12 21.91 21.05 19.99 38.17 19.04 19.91 19.92 21.67 21.30 19.09 38.21 19.28 19.20 19.75 21.23 21.06 19.28 38.25 19.71 19.66 19.93 21.82 20.56 20.37 38.29 20.66 19.86 19.07 21.90 19.70 19.23 38.33 19.88 20.33 19.25 21.27 19.75 19.00 38.37 19.11 20.59 18.43 21.05 20.43 19.22 38.41 20.57 21.08 18.61 21.97 20.51 19.24 38.45 19.73 19.23 18.37 21.69 21.21 19.05 38.49 18.47 19.80 19.94 21.27 20.39 19.32 38.53 18.43 19.86 19.74 21.12 20.61 19.73 38.57 18.58 19.82 19.90 21.89 21.75 20.55 38.61 18.41 19.90 20.33 21.70 19.93 19.81 38.65 19.22 19.67 19.92 21.88 19.71 20.58 38.69 19.11 20.56 19.11 21.74 19.86 22.42

38.73 19.30 20.37 19.18 21.26 19.02 19.18 38.77 19.12 21.28 19.81 21.03 19.85 19.93 38.81 19.25 19.72 19.21 21.17 19.18 19.83 38.85 19.21 20.57 20.44 21.23 20.33 19.97 38.89 19.04 20.43 19.27 21.19 21.30 19.77 38.93 19.14 20.56 19.72 21.91 21.11 19.86 38.97 17.11 20.37 19.96 21.01 20.58 19.72 39.01 17.33 21.30 19.71 21.24 21.67 19.96 39.05 17.78 21.03 20.55 22.40 21.87 19.08 39.09 17.96 21.91 20.46 23.24 21.08 18.58 39.13 18.47 20.41 20.52 22.43 21.11 18.64 39.17 18.57 21.31 21.02 21.84 21.66 18.42 39.21 17.15 21.72 21.20 22.40 19.21 19.24 39.25 17.26 21.26 19.13 22.55 19.15 19.77 39.29 17.20 21.18 19.90 22.42 19.06 20.50 39.33 17.11 20.52 19.13 22.56 19.30 19.74 39.37 17.88 20.50 19.84 21.76 19.78 19.83 39.41 18.43 20.46 19.90 21.07 20.56 21.81 39.45 22.53 20.54 19.23 21.24 19.75 23.04 39.49 21.74 20.40 18.62 21.01 19.26 22.55 39.53 19.27 20.52 18.54 21.31 19.08 21.09 39.57 19.06 20.46 19.21 22.42 19.27 21.91 39.61 17.93 21.22 19.76 22.55 19.04 22.40 39.65 18.54 20.35 19.99 22.37 19.19 23.22 39.69 17.94 19.86 19.76 21.92 19.19 22.41 39.73 16.64 20.47 20.55 21.74 20.37 22.55 39.77 16.37 20.55 20.47 21.85 20.62 21.83 39.81 17.25 19.71 20.60 21.76 19.81 22.46 39.85 17.81 19.92 19.73 21.79 20.59 22.63 39.89 18.55 19.80 19.26 21.68 21.07 21.73 39.93 18.41 19.81 18.43 22.50 19.20 22.50 39.97 19.29 20.41 19.30 23.07 19.81 22.45 40.01 17.11 19.91 19.08 22.53 19.19 22.49 40.05 17.91 19.74 18.61 22.55 19.03 22.37 40.09 18.56 19.94 19.08 22.41 19.25 23.84 40.13 16.52 21.11 18.57 22.60 19.89 24.01 40.17 17.91 21.28 19.17 22.36 19.84 23.04 40.21 17.05 21.12 19.25 22.58 20.00 22.58 40.25 17.20 19.97 18.43 22.38 19.11 22.32 40.29 17.17 20.51 18.56 21.90 19.91 23.22 40.33 17.96 20.58 17.79 21.73 19.75 24.42 40.37 17.82 20.53 17.85 21.89 19.87 25.18 40.41 17.28 19.81 18.84 21.74 20.38 22.47 40.45 17.02 19.83 19.78 22.55 20.58 21.71 40.49 17.96 19.78 19.08 22.41 21.17 21.27 40.53 17.92 20.53 18.51 22.55 20.54 20.44 40.57 17.80 19.71 18.31 23.02 20.59 20.55 40.61 18.58 19.76 18.62 23.85 21.06 21.74 40.65 18.43 19.82 18.39 24.61 21.29 21.20 40.69 18.52 19.86 19.22 23.19 20.34 19.68 40.73 17.76 20.40 19.10 23.32 20.57 19.78 40.77 17.89 20.45 18.57 23.15 20.44 20.65

40.81 19.80 21.08 18.49 22.64 20.47 19.07 40.85 20.64 19.92 18.56 22.41 20.39 19.95 40.89 20.47 20.45 18.57 22.57 21.27 20.42 40.93 21.29 20.52 19.25 23.12 21.10 21.24 40.97 22.51 20.47 19.24 23.15 21.84 21.78 41.01 21.03 20.54 19.76 23.07 21.88 21.81 41.05 21.18 19.73 19.99 22.48 21.75 21.71 41.09 18.48 19.91 19.20 21.95 21.96 19.85 41.13 17.96 19.75 19.24 21.72 21.05 21.93 41.17 18.44 20.65 19.21 22.59 21.27 20.34 41.21 19.91 20.38 19.90 23.03 21.72 21.96 41.25 19.14 21.24 19.12 23.95 23.19 21.07 41.29 19.92 21.09 19.96 24.44 23.84 21.26 41.33 21.21 21.95 19.76 23.90 23.93 20.42 41.37 19.87 21.77 20.03 24.51 24.36 20.55 41.41 19.14 22.63 19.67 23.95 23.22 20.43 41.45 18.98 23.79 19.93 22.37 22.54 22.54 41.49 19.23 25.30 19.07 22.58 22.55 21.84 41.53 19.77 23.15 19.90 22.41 23.25 20.49 41.57 20.57 24.65 19.78 22.56 23.75 19.87 41.61 19.04 24.52 19.96 23.17 23.30 21.09 41.65 18.67 24.63 19.71 23.21 22.46 21.24 41.69 18.51 23.87 20.55 21.91 21.85 20.47 41.73 18.62 23.85 20.39 21.76 21.85 21.26 41.77 19.86 26.62 19.89 21.93 21.90 21.67 41.81 19.72 23.09 19.73 21.79 21.88 22.56 41.85 20.58 23.17 18.52 22.61 21.78 21.87 41.89 20.46 24.40 19.80 22.34 22.60 22.47 41.93 19.90 23.24 19.86 22.58 22.45 21.22 41.97 19.73 23.03 19.78 22.39 23.25 21.08 42.01 21.21 24.49 19.87 22.59 21.73 21.22 42.05 22.44 24.48 19.00 23.10 19.97 21.06 42.09 21.97 23.85 19.22 23.86 19.70 21.92 42.13 19.17 23.07 18.96 23.72 20.53 21.66 42.17 19.80 23.15 19.97 23.83 21.12 24.54 42.21 19.86 22.37 19.82 23.71 21.85 24.62 42.25 20.43 22.55 19.89 23.25 21.85 23.13 42.29 21.94 23.06 19.87 22.56 21.09 21.92 42.33 21.08 21.90 19.92 23.22 21.96 21.64 42.37 20.61 21.07 19.85 23.27 21.70 21.21 42.41 20.40 21.23 19.82 22.47 21.90 21.10 42.45 19.96 20.37 19.87 23.24 21.75 21.11 42.49 21.83 20.57 19.21 22.40 22.62 22.44 42.53 20.50 20.49 19.31 22.61 21.68 19.18 42.57 20.53 20.58 19.12 21.67 21.18 19.32 42.61 20.35 20.40 19.28 21.85 19.93 20.44 42.65 21.23 21.29 19.14 21.77 21.72 20.59 42.69 21.08 21.69 19.91 21.22 24.65 19.73 42.73 19.90 21.23 19.77 22.38 22.44 19.87 42.77 20.46 20.50 19.96 22.49 22.57 19.75 42.81 18.59 21.26 19.07 22.38 22.39 19.31 42.85 18.41 21.13 19.31 21.84 22.55 19.72

42.89 18.62 20.56 19.81 21.89 19.76 22.46 42.93 17.86 19.94 20.57 21.87 19.90 21.24 42.97 17.05 19.87 20.40 22.66 19.75 20.37 43.01 17.93 19.87 19.96 23.13 20.60 19.86 43.05 18.45 19.18 19.10 23.96 19.71 21.05 43.09 19.25 19.17 19.26 23.08 19.89 20.56 43.13 19.08 19.72 19.74 23.24 19.96 19.10 43.17 17.93 20.46 19.23 21.69 19.73 19.18 43.21 18.51 19.70 18.41 22.55 19.93 19.12 43.25 18.54 20.59 19.25 22.34 20.40 19.15 43.29 17.22 21.65 19.77 23.26 20.58 19.28 43.33 17.16 19.86 19.91 23.10 19.07 19.08 43.37 16.55 19.78 19.73 22.45 19.85 19.24 43.41 16.48 19.89 19.26 22.28 20.42 19.05 43.45 17.26 19.73 19.06 21.78 21.17 19.83 49.80 17.79 20.42 19.04 23.75 20.55 23.91 49.84 17.31 19.35 17.95 22.60 19.07 23.11 49.88 17.19 18.53 18.49 22.39 20.50 18.50 49.92 17.30 19.13 18.53 21.90 20.99 19.83 49.96 16.57 19.69 18.40 21.19 19.88 18.62 50.00 15.71 19.90 19.27 21.06 20.45 19.05 50.04 15.90 20.40 19.07 21.25 20.51 19.98 50.08 15.77 19.31 19.32 22.43 19.80 19.03 50.12 16.00 19.18 19.17 21.79 20.55 19.34 50.16 16.46 19.17 18.53 21.74 20.39 19.13 50.20 15.96 18.51 18.59 22.56 21.24 18.59 50.24 15.88 19.11 19.01 23.02 19.82 17.86 50.28 16.50 19.94 19.30 22.62 20.60 17.08 50.32 16.56 19.03 19.19 23.00 20.47 17.27 50.36 15.11 19.89 19.22 23.95 20.58 17.80 50.40 14.64 19.73 18.38 22.45 19.92 18.62 50.44 15.05 19.23 19.93 22.44 19.03 19.12 50.48 16.61 19.91 19.70 22.50 18.58 19.24 50.52 16.53 20.39 19.90 23.07 18.40 19.10 50.56 17.34 20.59 20.55 23.17 18.54 19.31 50.60 17.20 19.70 20.52 23.15 19.09 20.37 50.64 16.50 19.22 19.18 23.24 19.88 20.61 50.68 15.98 19.80 19.81 22.36 20.38 19.83 50.72 17.11 20.59 19.20 22.58 20.58 19.94 50.76 17.21 20.46 19.06 22.40 19.76 19.81 50.80 16.40 19.90 21.22 22.59 20.62 19.95 50.84 17.33 19.89 20.47 23.03 20.44 19.82 50.88 16.40 19.68 19.28 23.98 20.57 20.43 50.92 16.05 19.87 20.46 23.15 20.38 20.60 50.96 15.88 21.06 20.48 23.93 18.57 20.40 51.00 16.51 21.26 18.60 23.22 18.42 18.59 51.04 16.61 21.11 19.04 22.37 18.50 18.45 51.08 15.81 20.62 19.25 22.50 19.27 18.60 51.12 16.55 19.04 19.84 22.47 21.67 19.80 51.16 17.13 20.50 19.28 21.84 22.49 19.92 51.20 16.62 20.51 19.04 22.35 21.12 20.37

51.24 16.53 20.40 19.27 23.91 23.21 21.30 51.28 16.66 21.13 21.82 23.09 23.09 21.77 51.32 15.92 20.41 20.47 22.57 23.22 24.59 51.36 16.48 20.65 19.25 22.37 20.49 23.76 51.40 15.90 21.07 19.00 22.62 20.56 19.27 51.44 15.90 21.97 19.30 23.18 19.82 19.83 51.48 16.67 19.90 19.05 23.04 20.62 19.04 51.52 16.36 19.72 18.60 23.75 20.43 19.88 51.56 18.00 21.27 19.14 23.75 19.87 20.41 51.60 16.49 22.38 19.88 24.53 20.53 19.81 51.64 16.64 22.55 20.51 24.41 20.38 21.80 51.68 16.63 19.78 18.59 23.97 20.53 27.26 51.72 16.40 22.61 17.90 23.77 19.72 20.99 51.76 16.00 21.81 18.50 23.27 20.56 20.61 51.80 16.57 21.29 18.60 23.85 21.05 19.77 51.84 16.63 21.23 19.77 23.96 21.24 19.28 51.88 15.79 20.38 19.92 24.53 21.11 18.44 51.92 16.03 20.51 19.65 23.83 21.83 19.28 51.96 15.77 21.13 19.24 24.52 24.43 17.91 52.00 17.28 23.21 19.13 24.44 21.26 18.44 52.04 17.24 24.43 19.94 23.84 20.50 18.60 52.08 16.42 23.28 19.09 23.13 21.10 19.08 52.12 17.28 21.02 19.91 23.19 21.21 19.27 52.16 17.76 21.22 19.19 24.40 21.70 20.46 52.20 17.94 21.22 19.81 24.53 21.16 20.56 52.24 17.74 20.39 19.85 24.42 21.11 20.38 52.28 17.26 21.16 19.70 24.61 21.90 19.90 52.32 16.55 21.12 19.93 23.71 20.34 20.43 52.36 16.61 21.27 19.78 23.84 20.55 21.94 52.40 17.13 22.40 20.59 23.90 21.03 21.08 52.44 17.17 21.93 20.45 23.78 21.99 19.95 52.48 17.88 21.70 19.85 23.80 21.18 19.86 52.52 17.84 21.89 19.92 23.68 21.24 19.88 52.56 17.90 23.18 20.31 23.89 22.51 19.86 52.60 17.13 22.38 21.81 24.48 23.11 20.46 52.64 17.37 22.62 21.77 24.55 21.17 20.53 52.68 17.16 22.37 21.90 25.15 21.73 21.02 52.72 17.26 23.20 20.46 25.28 22.55 21.17 52.76 16.62 23.06 21.91 24.40 22.43 19.84 52.80 16.43 22.55 21.81 23.99 23.20 18.55 52.84 16.58 23.18 21.22 23.82 23.07 19.13 52.88 16.44 21.10 21.20 23.93 23.30 18.58 52.92 15.96 23.22 21.10 24.52 23.69 19.78 52.96 17.12 22.40 21.21 24.34 21.85 20.59 53.00 17.94 21.80 21.02 23.94 21.81 20.30 53.04 17.79 21.80 22.56 23.74 21.29 21.29 53.08 17.91 22.61 21.76 23.97 21.80 21.81 53.12 16.55 22.39 21.24 25.10 22.45 19.85 53.16 16.37 23.27 21.11 25.23 22.50 19.84 53.20 16.62 22.44 21.26 25.05 21.09 19.69 53.24 16.44 23.15 21.89 25.35 22.53 19.89 53.28 15.34 23.21 21.76 24.41 23.67 21.09

53.32 15.84 23.07 21.88 23.82 22.49 21.18 53.36 16.67 22.53 22.44 23.25 22.48 21.13 53.40 17.24 22.41 23.87 23.68 21.76 21.21 53.44 17.12 24.00 20.35 23.91 21.87 20.40 53.48 17.21 24.48 20.55 25.06 22.58 19.96 53.52 17.79 23.96 21.15 25.29 21.05 20.45 53.56 17.28 23.84 21.24 24.44 21.27 20.59 53.60 17.11 23.82 21.08 24.50 21.05 21.19 53.64 17.97 22.50 21.19 24.41 21.29 21.92 53.68 16.43 23.11 21.80 25.27 22.37 21.23 53.72 15.98 22.55 21.01 26.51 22.59 21.22 53.76 16.67 23.11 21.81 26.67 23.84 23.20 53.80 17.08 23.94 21.78 25.85 23.21 23.72 53.84 17.31 23.84 21.90 26.02 23.16 23.26 53.88 17.11 23.90 21.65 25.89 21.81 23.81 53.92 16.62 23.19 21.29 25.91 22.50 23.21 53.96 16.41 25.05 21.06 26.64 23.70 21.72 54.00 17.34 23.17 21.89 25.07 23.93 21.22 54.04 17.71 23.75 21.26 26.52 21.12 20.37 54.08 17.97 22.55 21.11 26.51 21.24 26.63 54.12 18.54 23.06 21.84 27.24 21.73 24.44 54.16 18.32 21.95 22.46 25.75 21.26 22.58 54.20 19.87 22.43 22.54 26.68 21.06 22.34 54.24 18.43 23.19 21.69 25.80 21.22 22.61 54.28 18.58 24.56 21.19 25.97 20.43 23.15 54.32 18.41 23.06 21.13 26.48 21.93 23.83 54.36 18.00 23.26 21.71 28.01 22.36 21.88 54.40 17.83 23.10 21.76 28.65 22.56 22.30 54.44 19.29 23.93 20.68 28.52 22.57 22.51 54.48 18.54 23.13 21.21 28.01 21.83 19.82 54.52 19.00 23.98 21.66 25.81 21.84 19.83 54.56 21.15 25.19 22.57 25.99 21.02 21.09 54.60 17.86 24.45 22.41 25.13 21.16 21.91 54.64 17.92 24.65 21.89 28.03 22.42 22.40 54.68 17.11 25.83 22.36 27.13 22.54 21.25 54.72 17.98 25.97 22.59 27.30 23.09 19.07 54.76 18.45 24.41 22.48 26.51 24.56 19.97 54.80 18.48 23.94 23.27 26.67 23.11 20.39 54.84 18.49 24.51 23.79 26.58 23.32 19.90 54.88 17.75 24.62 23.08 25.83 21.73 21.22 54.92 18.55 24.48 23.12 25.93 21.89 22.42 54.96 19.04 25.08 23.01 26.44 21.90 22.50 55.00 17.95 25.20 22.57 25.29 23.25 21.71 55.04 18.42 24.42 22.37 25.15 23.25 21.91 55.08 18.60 25.26 23.27 25.93 22.39 21.77 55.12 17.83 25.08 23.75 25.76 24.48 22.53 55.16 17.92 25.32 23.27 26.00 24.39 21.73 55.20 17.92 26.56 23.83 25.85 22.46 21.19 55.24 19.68 25.91 23.95 26.05 23.17 21.08 55.28 19.21 23.83 23.85 25.86 23.22 21.28 55.32 18.51 23.75 23.87 25.20 23.05 21.82 55.36 18.60 25.89 23.13 25.30 23.93 23.28

55.40 18.40 25.06 22.98 24.42 21.69 22.47 55.44 19.30 23.98 23.26 24.49 22.64 22.51 55.48 18.44 23.76 23.02 25.11 22.50 23.27 55.52 19.18 23.89 23.23 26.68 21.83 22.36 55.56 18.59 23.85 24.43 27.82 22.57 23.17 55.60 18.42 24.49 23.96 26.69 23.75 23.07 55.64 19.25 23.82 23.06 26.47 23.90 21.24 55.68 18.50 23.09 23.20 25.95 23.78 20.40 55.72 19.25 23.24 21.87 25.93 23.89 21.28 55.76 19.73 23.71 22.38 25.85 21.64 21.11 55.80 19.98 23.87 23.21 26.02 21.90 21.22 55.84 18.37 23.74 23.76 25.11 21.77 21.81 55.88 17.83 24.66 23.90 25.87 21.89 21.96 55.92 17.88 23.89 24.35 27.23 23.13 21.79 55.96 19.00 24.41 23.94 26.61 23.31 23.17 56.00 19.31 23.95 23.10 26.51 23.21 21.83 56.04 18.42 23.84 23.97 26.67 23.19 22.30 56.08 17.84 22.51 23.19 26.48 22.49 21.84 56.12 18.43 22.37 22.50 25.97 23.19 21.70 56.16 19.96 22.65 22.56 26.51 23.88 21.29 56.20 20.46 22.95 22.38 26.00 22.32 21.74 56.24 20.59 23.96 23.32 25.23 22.63 22.54 56.28 20.48 23.94 23.04 25.05 23.12 22.42 56.32 21.04 23.01 21.85 26.00 23.13 21.93 56.36 19.86 23.83 21.73 25.13 22.41 21.74 56.40 19.78 23.79 21.96 25.83 23.27 21.33 56.44 20.57 23.30 21.75 25.77 22.43 21.67 56.48 21.04 23.08 21.88 26.62 21.94 21.94 56.52 19.95 23.28 21.20 27.15 21.80 21.12 56.56 19.82 23.07 21.09 26.69 21.93 21.89 56.60 20.66 23.87 21.85 25.21 21.83 21.94 56.64 21.09 23.96 21.05 26.01 21.74 20.98 56.68 21.16 24.44 21.17 25.89 21.84 21.29 56.72 21.20 25.21 21.79 24.53 21.69 21.10 56.76 20.44 25.10 21.93 24.59 23.93 21.23 56.80 20.54 24.60 21.80 25.02 25.11 20.42 56.84 20.40 24.43 21.94 25.89 23.25 21.31 56.88 21.25 24.72 22.40 26.53 22.37 21.78 56.92 20.44 23.76 23.24 26.66 22.60 21.91 56.96 21.31 23.88 22.50 25.09 22.40 22.44 57.00 22.48 23.88 22.44 25.29 21.28 23.90 57.04 22.50 24.31 21.27 25.13 21.78 23.89 57.08 20.52 23.86 20.44 25.29 23.16 22.54 57.12 19.74 23.77 21.17 25.15 23.93 21.90 57.16 19.19 23.91 22.37 25.94 22.44 21.04 57.20 19.76 24.40 21.99 25.90 22.55 21.88 57.24 20.56 25.27 21.71 25.73 23.15 22.45 57.28 20.43 23.86 21.92 25.91 23.15 21.85 57.32 21.94 23.69 22.43 25.19 23.13 20.45 57.36 24.39 24.50 22.43 25.89 23.26 21.22 57.40 23.88 23.82 23.19 25.84 22.39 21.67 57.44 22.50 23.27 23.05 25.91 22.58 22.59

57.48 21.65 23.79 23.18 25.09 23.04 21.73 57.52 20.56 23.93 23.07 26.04 23.33 20.62 57.56 21.12 23.84 23.96 25.20 23.15 20.48 57.60 21.88 25.28 24.48 26.02 23.24 20.67 57.64 22.40 25.24 25.31 26.59 23.79 21.09 57.68 23.96 25.05 24.42 27.16 24.01 21.90 57.72 27.16 24.50 25.23 28.02 23.85 21.74 57.76 24.51 23.67 25.90 27.14 24.56 21.13 57.80 23.16 24.59 25.04 27.89 25.25 21.32 57.84 21.71 24.45 25.92 27.15 24.38 21.03 57.88 21.13 23.94 25.80 26.67 23.85 21.16 57.92 21.08 23.79 25.23 27.12 24.48 21.79 57.96 21.24 23.68 24.38 27.37 23.28 24.58 58.00 21.04 24.50 23.95 26.46 24.39 22.39 58.04 21.28 24.47 23.80 27.40 24.56 23.91 58.08 21.74 25.22 23.24 27.17 24.40 23.06 58.12 23.17 27.11 23.80 27.30 25.38 24.67 58.16 23.86 27.40 24.65 28.00 25.15 24.45 58.20 23.76 24.41 23.77 27.28 25.25 24.69 58.24 24.61 25.95 23.79 27.26 25.91 24.45 58.28 23.75 25.92 23.23 27.83 25.79 23.95 58.32 22.51 27.06 22.38 27.26 25.25 25.91 58.36 21.77 27.30 23.27 26.46 24.42 24.40 58.40 20.61 23.16 21.12 27.29 23.19 23.18 58.44 19.12 22.53 21.24 27.12 22.36 23.02 58.48 19.04 22.38 21.03 26.62 22.46 24.60 58.52 19.82 22.58 21.24 25.10 23.16 25.79 58.56 19.76 23.09 21.05 26.00 23.93 26.62 58.60 21.23 24.55 21.29 27.24 23.00 25.79 58.64 21.04 23.88 20.40 28.01 23.28 25.96 58.68 20.65 23.74 20.59 27.21 23.79 27.88 58.72 20.39 23.83 20.50 26.48 23.26 25.99 58.76 21.24 23.72 21.02 26.51 23.79 24.37 58.80 21.26 24.60 21.20 26.39 24.51 22.60 58.84 21.75 23.84 21.09 27.40 24.55 22.48 58.88 20.48 24.62 21.23 27.22 26.39 23.16 58.92 19.09 24.43 21.05 27.29 25.97 23.13 58.96 19.24 24.52 21.93 27.84 23.15 22.42 59.00 19.05 24.56 21.78 27.35 23.17 23.28 59.04 19.95 24.40 21.77 27.21 23.71 21.69 59.08 19.21 24.56 21.21 26.56 23.96 21.27 59.12 19.07 24.53 21.07 27.24 23.77 21.70 59.16 19.24 24.60 21.25 28.06 23.97 22.55 59.20 19.75 25.10 20.40 26.51 23.75 22.42 59.24 19.97 23.96 21.79 26.63 26.02 22.60 59.28 19.70 24.50 21.06 26.63 24.42 23.83 59.32 19.91 23.81 21.97 26.49 23.26 23.17 59.36 19.78 25.23 21.74 27.23 23.95 23.24 59.40 19.83 24.41 20.68 26.50 23.77 22.39 59.44 20.53 24.48 21.18 27.36 23.84 23.84 59.48 19.02 23.70 21.90 27.13 23.71 22.41 59.52 19.27 24.60 22.56 27.33 24.68 21.93

59.56 19.72 23.80 21.74 27.24 24.48 21.65 59.60 19.92 23.95 21.80 27.35 25.88 21.22 59.64 19.73 23.79 21.79 26.42 25.13 21.05 59.68 19.93 23.91 20.58 27.46 25.32 27.36 59.72 19.88 23.91 21.07 27.26 24.41 24.49 59.76 19.77 23.71 21.31 27.24 23.93 21.92 59.80 19.90 24.54 20.41 26.58 23.03 22.56 59.84 19.75 25.71 21.26 25.84 23.25 24.40 59.88 19.23 26.68 21.12 25.18 22.51 21.20 59.92 18.44 25.80 21.19 25.83 22.61 21.10 59.96 18.64 24.66 21.19 26.64 23.87 19.88 60.00 19.14 25.10 21.72 27.20 23.09 20.45 60.04 18.57 24.47 21.25 28.10 23.91 21.88 60.08 19.20 24.54 21.72 28.56 23.74 22.39 60.12 19.65 25.07 21.89 28.08 23.87 23.28 60.16 20.49 25.90 21.77 27.12 25.15 23.11 60.20 19.72 24.45 21.95 26.62 26.61 23.27 60.24 19.29 25.32 22.36 28.69 25.76 22.49 60.28 19.74 25.13 22.63 28.54 24.58 23.18 60.32 20.61 26.72 23.22 28.01 24.47 23.18 60.36 21.85 25.85 23.05 28.48 26.00 23.84 60.40 21.69 25.18 22.58 28.64 23.68 23.88 60.44 20.59 25.99 22.42 29.26 23.94 23.00 60.48 21.09 25.88 22.55 28.64 23.12 24.01 60.52 24.61 25.29 22.46 27.17 23.16 23.05 60.56 21.00 24.39 21.22 27.38 23.89 24.53 60.60 19.25 24.63 21.08 27.18 23.67 25.11 60.64 19.73 25.10 21.28 27.40 23.28 24.58 60.68 20.56 23.90 21.83 27.11 23.10 24.39 60.72 20.48 23.83 21.92 27.31 23.89 23.96 60.76 20.48 24.43 21.83 26.61 23.75 24.49 60.80 20.56 25.23 22.35 27.26 23.97 23.33 60.84 19.77 24.49 22.61 26.64 24.28 23.81 60.88 19.94 24.55 21.75 26.37 24.65 23.12 60.92 19.80 24.41 21.91 27.24 24.58 23.88 60.96 20.01 24.62 21.76 27.24 25.21 24.02 61.00 20.49 24.45 22.58 28.04 26.52 24.52 61.04 19.95 25.25 23.05 27.06 23.10 24.43 61.08 19.89 25.20 22.62 28.09 23.87 23.93 61.12 20.31 25.68 22.40 27.18 23.68 23.70 61.16 20.53 25.88 22.49 27.40 23.82 24.58 61.20 19.73 25.21 21.83 27.28 23.78 24.47 61.24 19.22 25.25 22.34 28.02 23.85 24.61 61.28 19.05 25.05 22.58 26.59 22.29 24.44 61.32 19.35 26.05 22.35 27.18 23.26 24.58 61.36 19.18 25.86 22.58 26.61 24.51 25.25 61.40 19.83 24.62 22.48 26.47 23.99 25.80 61.44 19.95 25.36 23.26 28.03 23.74 26.65 61.48 19.78 24.37 23.17 27.86 23.95 25.87 61.52 19.89 24.54 21.91 27.29 23.20 22.58 61.56 19.75 25.09 21.87 26.48 23.71 23.70 61.60 19.33 24.61 21.70 27.35 24.48 23.88

61.64 19.07 24.48 22.57 27.20 25.09 23.79 61.68 19.83 24.63 21.73 29.45 26.52 23.95 61.72 19.89 24.55 22.51 27.23 29.97 23.84 61.76 20.38 24.51 23.04 26.62 25.94 23.97 61.80 20.47 24.54 23.22 26.53 24.36 23.79 61.84 20.42 25.11 23.74 26.54 23.95 23.91 61.88 21.27 24.50 22.61 27.31 23.75 23.88 61.92 22.43 24.48 23.13 25.79 23.31 23.26 61.96 21.91 25.31 23.30 25.92 23.71 24.49 62.00 22.42 25.13 22.49 25.85 23.93 25.74 62.04 21.76 25.36 21.70 27.36 24.57 25.13 62.08 20.58 25.17 22.45 27.93 23.07 24.40 62.12 19.73 25.14 23.07 29.44 23.89 24.58 62.16 18.58 24.58 23.24 28.44 24.40 24.44 62.20 20.42 24.49 23.07 26.73 24.57 23.93 62.24 23.95 23.88 23.25 26.47 24.41 23.06 62.28 21.78 24.39 22.35 26.65 24.60 22.61 62.32 21.85 25.30 22.60 26.61 25.11 22.44 62.36 21.89 23.75 22.41 25.84 25.28 22.59 62.40 20.39 23.94 22.57 26.70 27.22 23.13 62.44 19.95 23.88 22.40 27.08 27.35 23.22 62.48 19.77 24.43 22.54 27.36 25.85 23.19 62.52 20.56 24.55 22.59 27.18 25.23 25.15 62.56 20.96 24.35 22.33 27.31 25.92 23.23 62.60 21.31 25.26 22.45 27.13 25.06 23.79 62.64 20.55 26.49 22.46 27.40 25.89 23.20 62.68 20.33 24.63 22.53 27.13 27.15 24.37 62.72 21.26 25.91 22.37 27.41 26.03 25.22 62.76 20.45 24.61 21.94 27.26 25.83 25.14 62.80 20.59 25.21 22.40 28.11 25.23 25.27 62.84 21.07 25.14 22.62 27.25 25.12 24.39 62.88 21.25 25.17 21.87 27.23 25.34 24.69 62.92 21.74 25.08 21.84 27.28 25.15 24.47 62.96 20.53 25.94 21.24 27.08 26.00 25.31 63.00 20.58 26.48 21.66 27.23 25.12 25.84 63.04 21.71 26.69 22.51 27.82 25.19 25.99 63.08 21.15 25.12 22.42 27.99 25.20 25.95 63.12 20.37 25.94 22.57 27.14 25.75 25.78 63.16 21.24 25.95 22.32 27.37 26.70 25.87 63.20 22.44 25.85 22.65 27.88 25.13 27.81 63.24 22.61 25.26 22.49 28.13 25.90 27.88 63.28 24.58 25.83 22.58 27.99 25.12 27.86 63.32 25.06 26.67 21.80 27.88 25.22 26.63 63.36 21.16 26.46 21.69 28.08 23.72 25.11 63.40 21.74 25.97 21.83 27.82 23.93 26.03 63.44 21.90 25.13 21.09 27.36 23.11 26.51 63.48 22.38 24.70 21.23 27.13 23.94 26.02 63.52 22.57 24.52 21.72 27.98 23.81 24.98 63.56 22.46 23.71 22.61 27.87 23.97 24.67 63.60 22.63 23.16 22.33 27.28 24.59 23.78 63.64 21.32 23.05 22.64 27.85 24.47 23.93 63.68 19.70 23.93 22.44 28.06 23.88 23.20

63.72 19.91 24.43 22.47 27.17 24.44 23.05 63.76 20.45 25.30 22.56 28.10 24.47 23.85 63.80 21.27 24.50 22.35 25.83 25.12 23.78 63.84 21.05 25.38 22.47 27.37 24.59 24.59 63.88 21.34 25.20 22.43 27.94 24.43 29.27 63.92 21.04 24.45 22.55 27.87 23.96 28.07 63.96 21.15 25.23 21.69 28.65 23.70 26.46 64.00 22.60 25.20 22.54 27.79 24.56 26.69 70.35 20.74 27.03 26.88 33.34 24.00 26.86 70.39 19.78 24.73 26.43 30.72 24.18 25.71 70.43 19.25 24.91 26.91 29.10 24.03 24.04 70.47 20.55 25.39 26.38 28.40 24.86 22.78 70.51 21.46 26.25 26.95 28.40 26.16 23.41 70.55 21.27 24.01 26.37 28.44 26.38 23.55 70.59 21.49 27.82 26.89 27.65 26.15 22.61 70.63 20.62 28.97 27.17 27.76 26.32 22.84 70.67 20.07 24.97 27.52 28.99 26.86 22.74 70.71 20.63 24.80 27.03 29.94 28.56 22.86 70.75 20.63 24.89 26.85 28.95 26.15 24.12 70.79 20.76 26.14 27.85 28.47 26.26 24.97 70.83 22.63 27.78 26.82 27.64 26.14 24.17 70.87 22.13 25.50 27.15 27.82 25.63 24.20 70.91 21.93 25.69 26.83 28.33 26.16 24.14 70.95 21.39 26.15 27.89 29.29 25.74 24.06 70.99 21.31 25.68 28.38 28.99 25.42 24.86 71.03 22.82 25.43 27.81 28.48 27.11 25.47 71.07 21.29 25.68 27.04 28.41 26.16 25.61 71.11 22.15 26.32 27.63 28.47 25.71 25.41 71.15 22.00 26.38 28.43 29.15 25.55 26.30 71.19 24.25 25.54 28.51 29.87 25.68 26.16 71.23 23.47 26.34 29.15 29.88 24.81 26.36 71.27 23.34 25.61 28.28 30.62 24.92 25.48 71.31 24.93 26.87 28.42 29.85 24.90 24.16 71.35 23.33 26.31 28.35 29.73 24.78 24.14 71.39 23.41 26.11 29.85 30.68 26.34 23.47 71.43 21.95 26.25 30.42 31.22 25.49 28.96 71.47 22.10 26.27 29.16 30.58 26.31 29.92 71.51 21.95 26.37 28.37 28.97 26.16 25.52 71.55 22.17 28.19 27.69 29.16 26.34 26.43 71.59 21.33 31.22 28.32 28.95 25.41 26.18 71.63 22.16 26.91 29.22 29.21 25.58 26.36 71.67 22.73 27.08 28.95 29.68 25.44 27.02 71.71 22.02 26.95 29.20 29.87 26.42 26.41 71.75 22.83 28.55 29.00 29.69 26.20 27.59 71.79 22.62 26.88 28.48 30.74 26.36 27.86 71.83 22.76 28.55 28.25 29.83 26.20 26.85 71.87 21.96 28.26 28.48 30.55 26.37 27.81 71.91 21.38 29.18 27.65 30.52 25.58 26.33 71.95 21.93 26.92 28.43 31.27 24.90 26.34 71.99 22.11 27.01 28.37 30.48 24.89 24.85 72.03 21.97 26.94 28.50 30.67 25.53 24.77

72.07 21.44 28.46 29.10 30.49 28.41 24.92 72.11 22.06 29.91 27.77 31.38 26.16 25.41 72.15 22.07 29.68 27.58 31.14 24.95 25.57 72.19 22.08 29.91 28.45 31.33 25.41 27.58 72.23 21.83 28.95 28.22 31.22 26.31 30.56 72.27 22.04 29.14 28.48 31.32 25.55 29.81 72.31 22.74 26.94 27.58 31.17 25.53 29.96 72.35 23.48 27.08 28.52 31.38 25.53 28.28 72.39 23.31 27.71 28.95 31.90 24.90 27.04 72.43 22.81 27.77 27.12 31.36 24.04 26.86 72.47 22.70 27.55 27.65 31.17 24.93 27.83 72.51 22.94 28.56 28.53 32.09 25.43 26.20 72.55 23.30 29.03 28.31 31.93 25.63 26.33 72.59 22.83 28.51 29.26 32.78 26.15 26.91 72.63 22.80 29.05 29.01 32.64 26.35 24.98 72.67 23.30 29.25 29.22 32.27 25.54 24.69 72.71 22.75 28.28 29.08 31.87 26.42 24.25 72.75 21.91 28.48 29.24 31.38 26.21 24.82 72.79 22.11 28.35 29.05 31.21 29.29 24.97 72.83 21.14 27.71 29.29 32.09 29.10 24.87 72.87 20.73 27.04 29.02 32.60 25.73 24.85 72.91 22.05 27.56 29.97 32.13 26.23 26.22 72.95 24.25 27.83 29.70 31.96 26.36 27.61 72.99 22.75 28.25 29.29 32.08 26.26 31.30 73.03 22.74 29.87 29.76 31.86 26.94 27.55 73.07 24.90 29.72 29.95 32.13 26.26 25.63 73.11 21.21 31.32 29.69 32.02 25.51 24.68 73.15 21.39 31.99 29.30 32.74 25.64 24.20 73.19 21.32 31.31 29.73 32.06 26.13 24.05 73.23 21.40 30.51 30.71 32.84 26.31 24.84 73.27 21.27 30.63 29.86 32.76 26.11 24.11 73.31 20.76 29.76 30.71 32.76 25.62 24.88 73.35 21.29 29.21 30.47 32.72 26.13 25.45 73.39 21.46 29.77 31.35 32.60 26.98 24.93 73.43 21.25 29.91 30.56 33.46 26.22 25.43 73.47 22.16 30.44 31.41 33.29 26.99 28.53 73.51 23.44 29.92 31.86 33.47 27.56 28.36 73.55 22.63 31.21 32.13 33.16 29.20 24.25 73.59 22.74 29.70 31.90 33.43 29.73 23.36 73.63 22.63 30.64 30.58 32.50 28.60 22.90 73.67 22.15 29.76 30.53 33.53 29.05 24.02 73.71 22.04 29.87 30.61 33.31 28.54 24.33 73.75 20.75 29.05 31.27 34.28 27.66 24.89 73.79 20.57 29.23 31.32 34.08 27.79 26.36 73.83 20.73 29.75 31.31 34.89 27.71 26.32 73.87 21.33 29.20 31.93 34.11 28.47 26.24 73.91 22.16 32.66 32.06 34.18 26.98 26.35 73.95 22.05 32.09 31.16 33.41 27.03 26.86 73.99 22.73 28.97 30.64 33.47 27.76 27.76 74.03 23.46 29.29 31.17 33.35 27.53 27.58 74.07 21.21 29.78 31.26 32.85 28.46 27.69 74.11 20.76 30.66 30.47 34.01 28.25 29.00

74.15 20.59 29.09 30.63 34.24 28.36 26.27 74.19 21.46 30.55 31.13 33.39 29.69 25.52 74.23 21.23 29.92 31.30 33.52 31.39 26.35 74.27 22.23 30.44 31.11 33.36 27.63 25.48 74.31 22.05 32.05 31.38 32.82 28.43 26.35 74.35 22.18 31.13 31.86 32.60 28.33 26.24 74.39 21.34 32.09 32.00 32.87 28.50 26.36 74.43 20.66 30.43 31.82 32.57 28.32 26.15 74.47 20.74 30.63 32.01 35.09 28.46 26.43 74.51 21.16 29.79 31.88 34.14 28.31 26.25 74.55 22.03 29.89 32.04 34.25 28.53 27.11 74.59 21.97 31.29 31.86 34.16 27.58 26.91 74.63 23.53 32.79 31.38 34.29 28.56 27.04 74.67 22.68 31.92 31.94 32.59 29.05 26.82 74.71 21.46 30.62 32.08 32.88 28.50 29.22 74.75 21.23 31.19 31.16 32.02 28.27 29.81 74.79 21.47 30.65 30.64 32.78 29.23 26.25 74.83 20.56 31.13 29.71 32.78 28.38 26.26 74.87 21.54 31.44 30.44 31.90 28.45 26.26 74.91 21.99 31.90 30.44 32.72 32.79 25.58 74.95 22.00 31.93 30.61 33.47 31.88 25.40 74.99 21.45 32.08 31.18 33.45 27.72 24.90 75.03 21.15 31.24 30.61 33.32 27.63 24.01 75.07 22.12 31.32 30.48 33.46 28.48 24.85 75.11 20.62 31.13 30.64 32.55 28.23 26.21 75.15 21.43 31.35 30.42 33.57 29.15 26.41 75.19 22.00 31.22 30.63 31.85 29.01 26.89 75.23 21.43 30.56 29.75 31.36 30.72 27.02 75.27 23.31 31.13 30.68 32.68 35.50 26.86 75.31 22.91 32.78 30.49 33.43 36.40 27.03 75.35 22.68 34.02 29.92 33.39 26.86 26.16 75.39 24.13 31.32 29.79 33.45 27.05 26.38 75.43 23.48 30.53 29.92 33.39 26.82 26.15 75.47 23.28 30.70 29.75 33.48 27.15 26.36 75.51 24.16 31.17 32.15 33.37 26.88 26.14 75.55 23.38 31.39 31.20 33.49 27.85 25.71 75.59 23.52 31.17 31.40 32.64 26.76 26.16 75.63 22.70 32.76 31.26 32.76 27.84 26.44 75.67 23.59 32.78 31.38 32.51 28.26 28.30 75.71 24.18 32.57 30.55 32.84 28.53 29.22 75.75 24.29 32.83 30.71 33.39 28.43 29.82 75.79 24.16 32.66 30.49 33.52 27.78 29.19 75.83 25.44 31.30 30.70 33.34 27.64 27.65 75.87 26.38 31.97 31.27 33.61 27.79 27.75 75.91 24.68 31.36 30.68 33.32 27.72 27.74 75.95 24.22 31.17 30.46 34.29 28.31 26.99 75.99 24.71 31.35 30.66 34.11 26.99 27.06 76.03 24.24 31.95 30.60 34.31 28.33 28.94 76.07 24.10 32.13 29.94 33.30 27.72 28.43 76.11 25.00 32.72 29.82 33.61 27.54 26.83 76.15 26.24 32.05 30.54 32.68 28.45 27.79 76.19 27.04 30.63 31.31 33.55 29.03 27.63

76.23 26.26 31.21 31.22 34.82 29.89 27.07 76.27 26.97 32.82 31.36 34.33 29.76 28.30 76.31 26.32 33.30 31.99 34.02 30.62 27.84 76.35 26.13 33.44 31.99 33.62 28.35 27.61 76.39 23.46 32.66 32.03 33.40 27.74 32.10 76.43 24.82 32.03 32.03 33.59 27.61 32.64 76.47 24.93 32.65 31.97 33.48 27.81 27.77 76.51 24.70 32.02 31.33 33.39 28.35 27.71 76.55 24.97 31.14 31.87 33.48 28.54 27.84 76.59 24.75 35.76 32.05 32.69 28.36 28.36 76.63 23.51 36.20 32.59 33.46 28.61 27.79 76.67 23.42 34.27 33.46 33.43 28.33 27.62 76.71 22.80 32.64 33.32 34.23 27.76 31.49 76.75 22.75 32.14 32.09 33.32 28.36 29.81 76.79 24.07 32.69 31.24 34.20 28.48 29.20 76.83 24.21 34.15 31.27 34.01 28.44 28.45 76.87 23.35 32.06 31.21 34.20 29.19 27.05 76.91 23.46 31.11 32.78 33.96 29.85 27.01 76.95 22.65 31.26 31.91 34.19 29.86 27.58 76.99 23.49 31.04 31.37 34.07 29.82 27.81 77.03 23.33 35.07 31.24 34.24 29.80 26.86 77.07 23.58 32.65 31.35 34.06 28.51 29.82 77.11 23.39 31.26 31.24 34.19 28.97 28.28 77.15 24.27 30.45 31.99 34.08 29.13 29.12 77.19 23.48 31.33 31.90 34.97 28.35 29.01 77.23 24.09 31.17 31.37 34.73 28.47 28.51 77.27 23.48 30.70 31.20 34.27 29.05 26.98 77.31 23.28 30.39 30.58 33.39 29.19 27.01 77.35 23.57 29.98 31.14 34.26 29.09 27.51 77.39 24.03 30.64 31.38 34.10 29.20 28.50 77.43 24.88 30.57 31.13 34.23 29.14 28.30 77.47 24.07 29.92 32.06 34.11 29.19 27.78 77.51 23.56 29.69 31.87 34.27 29.69 27.61 77.55 23.35 29.90 32.10 34.12 29.23 27.82 77.59 23.50 30.56 31.94 34.23 28.96 29.04 77.63 23.40 30.64 30.68 34.08 29.20 28.52 77.67 22.65 29.79 30.58 34.24 28.96 29.10 77.71 23.46 29.88 30.67 33.31 29.89 27.84 77.75 22.70 29.78 31.19 34.26 29.78 27.71 77.79 22.82 30.68 31.47 34.77 28.43 27.06 77.83 23.36 30.49 31.97 34.23 29.06 27.72 77.87 27.09 29.99 31.40 34.05 29.28 27.01 77.91 26.91 30.54 31.91 34.20 28.40 27.65 77.95 22.89 31.39 32.17 34.12 28.54 26.27 77.99 22.67 30.43 31.13 34.28 29.05 26.98 78.03 23.56 33.63 31.42 34.03 29.98 26.95 78.07 24.14 37.06 31.18 34.99 31.23 27.74 78.11 23.47 34.92 31.44 34.76 29.86 28.23 78.15 23.45 32.79 31.92 34.33 28.46 28.56 78.19 24.66 31.12 31.42 33.47 29.23 29.02 78.23 28.48 32.03 31.36 33.55 28.43 29.12 78.27 24.04 32.64 31.16 33.50 29.09 28.36

78.31 23.52 31.40 30.64 33.54 30.63 28.52 78.35 23.36 31.17 31.13 33.34 30.42 26.97 78.39 23.50 30.56 31.33 33.52 29.89 27.77 78.43 24.04 29.76 31.83 34.15 29.68 28.27 78.47 24.26 30.64 31.32 34.20 29.83 30.61 78.51 26.21 31.11 31.14 34.21 29.73 28.31 78.55 29.19 31.40 31.37 34.14 29.09 28.54 78.59 26.21 29.81 31.12 34.20 29.04 28.24 78.63 26.96 31.41 30.55 34.81 29.83 28.56 78.67 27.08 32.73 30.54 34.25 29.04 30.48 78.71 26.13 34.27 31.16 33.98 29.18 27.83 78.75 24.17 31.95 30.55 33.43 29.05 26.86 78.79 23.36 33.44 31.30 33.27 29.21 32.12 78.83 24.85 33.49 31.14 33.50 29.06 30.53 78.87 25.44 33.30 31.37 32.65 29.95 28.45 78.91 26.32 34.15 31.14 34.17 30.48 29.03 78.95 26.22 34.76 31.38 34.15 30.67 28.54 78.99 27.12 34.85 31.17 33.47 29.75 29.01 79.03 26.11 33.35 31.40 33.41 29.98 30.58 79.07 25.71 33.50 30.55 33.49 29.80 29.82 79.11 24.79 34.01 31.42 33.37 29.99 29.13 79.15 24.21 34.95 31.94 33.43 30.48 29.19 79.19 24.20 34.78 32.12 33.26 29.23 28.27 79.23 24.70 34.29 31.19 33.52 29.16 26.33 79.27 24.92 33.37 31.39 34.80 29.96 25.42 79.31 24.14 33.55 31.37 34.97 30.58 26.33 79.35 24.26 34.02 31.32 34.06 30.65 26.12 79.39 23.31 34.18 31.12 34.28 30.56 27.12 79.43 24.26 33.47 31.35 34.02 29.11 26.89 79.47 24.04 33.39 31.29 33.54 29.21 27.74 79.51 24.96 34.29 32.15 33.34 28.97 27.65 79.55 24.80 33.25 31.92 32.82 29.18 26.98 79.59 24.13 32.69 32.11 33.37 29.79 26.95 79.63 24.87 31.93 32.05 34.32 29.18 27.11 79.67 24.80 32.81 32.75 34.03 29.03 26.93 79.71 24.92 34.06 32.85 34.35 29.87 26.97 79.75 24.84 33.50 32.72 33.23 30.47 26.82 79.79 24.25 31.91 32.77 34.36 30.64 27.16 79.83 24.07 32.12 31.96 34.19 30.46 27.61 79.87 24.25 31.95 32.01 34.27 31.38 28.54 79.91 24.09 32.81 31.24 34.16 31.13 29.04 79.95 23.59 32.77 32.02 34.25 31.40 29.95 79.99 24.01 32.75 31.13 34.07 31.23 29.02 80.03 24.92 32.09 31.36 34.93 30.66 28.52 80.07 25.70 32.60 31.21 34.86 30.45 29.76 80.11 24.04 32.77 31.26 34.85 30.71 28.52 80.15 23.52 31.90 31.16 34.19 31.30 26.86 80.19 23.30 32.70 31.30 34.07 31.39 27.08 80.23 23.44 32.57 31.17 34.31 31.29 27.02 80.27 24.02 34.20 31.33 34.02 30.73 27.64 80.31 24.25 33.29 31.18 34.95 29.73 27.02 80.35 24.07 32.84 31.31 34.70 29.96 26.91

80.39 24.91 33.35 31.23 34.92 29.85 27.03 80.43 24.82 34.24 32.04 33.99 29.85 26.14 80.47 25.59 34.09 31.92 34.07 29.91 25.63 80.51 23.50 32.94 31.35 34.64 38.32 26.14 80.55 23.29 32.68 31.17 35.73 34.20 27.64 80.59 23.45 32.02 32.13 34.73 31.85 25.51 80.63 24.06 32.00 31.90 34.24 31.99 27.02 80.67 24.21 31.87 31.31 34.08 31.27 28.26 80.71 24.00 32.82 31.20 33.53 30.57 29.19 80.75 24.28 31.87 31.37 34.11 31.21 29.00 80.79 24.71 32.10 31.13 33.45 30.57 27.83 80.83 25.01 32.69 32.08 33.30 30.47 26.93 80.87 24.15 33.49 31.90 34.19 29.92 27.08 80.91 24.92 33.30 32.03 35.62 29.64 26.91 80.95 24.18 32.82 31.86 34.94 30.64 27.87 80.99 23.95 31.88 31.44 34.81 29.78 27.68 81.03 24.25 32.13 31.91 34.24 29.96 27.76 81.07 24.11 31.93 32.84 34.08 30.48 26.92 81.11 23.49 32.11 31.94 34.99 30.67 27.73 81.15 24.06 31.96 32.08 34.03 30.51 27.69 81.19 24.23 32.83 31.94 36.48 30.66 29.18 81.23 23.36 33.54 32.13 34.08 31.28 27.77 81.27 24.26 33.31 31.87 34.19 31.33 28.30 81.31 24.75 34.15 32.12 34.86 30.49 28.47 81.35 24.29 33.40 32.72 34.23 30.62 27.59 81.39 24.17 33.52 32.85 34.01 29.78 27.07 81.43 24.75 33.36 32.02 34.24 30.56 27.55 81.47 26.31 32.09 31.39 34.07 30.55 27.05 81.51 24.70 32.64 31.22 35.03 30.42 29.02 81.55 25.50 33.57 32.12 34.14 31.31 28.41 81.59 24.82 34.11 32.67 34.18 31.20 29.69 81.63 25.68 33.56 33.40 33.36 30.61 31.37 81.67 25.45 32.70 32.76 33.52 29.73 28.91 81.71 26.38 32.78 32.74 34.01 30.55 29.16 81.75 25.49 33.46 32.76 35.02 30.47 28.37 81.79 26.40 33.31 32.83 34.84 29.97 29.92 81.83 25.58 33.53 32.76 34.97 29.80 30.43 81.87 24.98 33.25 32.06 34.90 29.87 29.20 81.91 24.91 32.88 32.00 34.31 28.97 29.80 81.95 24.76 33.40 32.02 33.49 30.61 28.46 81.99 24.17 34.93 32.10 33.44 30.53 29.04 82.03 24.15 35.52 31.92 34.24 30.60 28.54 82.07 25.61 32.79 32.09 34.16 30.47 28.33 82.11 23.34 32.64 32.58 34.25 29.90 28.47 82.15 24.27 33.48 32.75 34.90 30.53 28.34 82.19 24.07 33.36 31.85 38.55 30.68 29.25 82.23 23.57 32.84 31.97 36.31 30.53 30.62 82.27 24.01 32.68 31.84 34.95 29.95 30.56 82.31 24.27 32.79 32.84 34.78 30.57 29.10 82.35 24.18 32.68 31.84 33.47 30.62 29.13 82.39 27.01 32.65 31.96 34.00 31.41 29.18 82.43 26.34 33.50 31.92 34.96 30.54 28.93

82.47 24.05 33.27 32.72 34.70 30.56 28.50 82.51 23.41 32.73 32.63 34.96 31.20 28.26 82.55 23.39 33.34 32.83 33.97 31.29 29.20 82.59 24.16 32.77 32.57 34.93 31.22 29.05 82.63 24.04 31.84 32.04 34.06 32.66 29.21 82.67 24.24 32.94 31.86 34.98 34.75 29.77 82.71 24.09 33.34 32.74 34.75 32.74 30.53 82.75 25.70 32.83 31.85 34.20 32.58 31.18 82.79 28.34 32.66 32.08 34.01 32.10 29.94 82.83 24.92 32.78 31.14 34.19 32.64 29.75 82.87 24.22 34.15 32.15 34.02 32.69 29.91 82.91 24.76 33.55 31.88 34.94 31.88 29.00 82.95 24.10 33.46 32.10 35.55 32.10 28.51 82.99 24.12 35.47 31.96 35.64 31.16 30.49 83.03 24.27 34.19 32.06 35.59 30.64 30.64 83.07 24.02 34.10 31.87 36.35 29.79 28.31 83.11 24.93 34.18 32.12 36.16 29.99 29.22 83.15 25.51 33.32 32.63 36.41 30.46 29.77 83.19 24.24 34.29 31.38 36.27 31.42 28.54 83.23 24.17 33.39 31.95 37.16 31.17 27.55 83.27 24.93 33.50 32.15 36.20 31.40 29.28 83.31 24.89 34.82 31.96 36.39 31.09 29.02 83.35 24.01 35.75 32.82 36.91 33.58 30.66 83.39 24.13 33.37 32.69 37.15 32.77 31.32 83.43 24.85 32.84 32.14 37.61 33.50 28.46 83.47 24.86 32.58 31.95 37.19 32.72 29.14 83.51 25.48 32.82 32.79 36.96 32.75 29.09 83.55 24.25 32.70 32.75 37.10 32.67 28.47 83.59 23.99 31.88 32.77 37.02 32.58 27.55 83.63 24.23 32.77 31.94 37.92 32.06 26.30 83.67 24.68 33.25 32.02 36.92 31.16 26.12 83.71 25.02 32.69 32.04 37.15 32.10 26.24 83.75 24.74 33.40 31.91 36.98 33.34 27.68 83.79 26.38 33.47 32.79 36.39 34.94 28.43 83.83 25.54 33.97 32.67 36.30 34.75 28.99 83.87 24.81 33.59 31.29 37.10 34.21 28.55 83.91 25.60 32.64 31.85 37.00 34.19 28.40 83.95 24.04 34.23 32.01 37.19 34.21 28.54 83.99 24.13 34.14 31.82 36.99 34.75 28.35 84.03 24.09 33.55 31.95 38.69 35.01 27.84 84.07 24.92 33.45 31.86 38.48 36.25 28.28 84.11 24.75 33.48 31.97 37.94 37.87 28.58 84.15 25.00 33.47 31.17 37.06 38.46 29.02 84.19 24.71 33.40 31.99 37.26 35.74 27.81 84.23 24.89 33.39 31.94 36.97 33.36 28.37 84.27 26.32 32.52 31.44 37.19 34.20 28.47 84.31 25.60 32.85 31.21 37.67 32.67 29.88 84.35 24.11 32.69 31.33 38.66 32.83 30.56 84.39 23.29 33.52 31.16 38.38 32.65 31.27 84.43 24.24 34.02 31.27 38.61 32.15 31.19 84.47 24.06 34.33 31.19 37.83 31.88 29.15 84.51 24.87 33.34 31.37 37.85 32.08 29.73

84.55 24.12 34.97 31.22 37.84 31.95 29.12 90.90 25.65 31.20 30.67 38.67 32.09 27.09 90.94 24.10 29.92 29.04 35.63 29.70 24.70 90.98 22.08 29.79 29.22 35.06 29.94 24.92 91.02 23.30 31.31 29.01 34.86 31.26 25.55 91.06 24.28 29.71 30.02 35.72 30.66 25.62 91.10 24.05 30.72 29.80 35.45 29.77 24.76 91.14 23.59 31.12 29.99 35.76 31.33 25.66 91.18 23.38 29.98 31.11 35.48 30.57 25.49 91.22 24.18 31.24 29.99 35.02 31.31 26.40 91.26 24.12 34.24 30.54 34.80 31.36 26.20 91.30 23.47 34.18 30.63 35.66 29.77 26.40 91.34 23.47 31.88 30.48 36.24 30.70 26.20 91.38 23.38 32.06 30.70 37.13 32.01 26.42 91.42 23.55 31.13 30.46 37.02 32.81 25.51 91.46 23.96 31.28 30.65 35.66 32.57 26.42 91.50 24.13 31.85 31.88 36.26 30.68 26.79 91.54 24.09 32.04 32.08 36.31 30.39 27.08 91.58 24.21 31.08 30.44 36.21 30.70 26.22 91.62 24.73 31.29 30.66 36.46 31.27 26.42 91.66 24.92 31.88 30.46 36.20 32.08 26.84 91.70 24.74 31.96 29.96 36.41 31.85 27.78 91.74 25.00 31.86 30.33 36.90 32.81 29.03 91.78 25.50 32.72 30.68 37.88 34.77 29.24 91.82 24.96 33.39 29.67 36.23 35.68 28.37 91.86 25.57 33.43 30.58 35.68 34.15 29.26 91.90 24.95 34.05 31.17 36.43 34.96 29.02 91.94 25.52 34.93 33.47 36.26 34.12 29.86 91.98 25.58 34.82 33.99 37.14 34.16 30.56 92.02 24.87 34.19 32.76 37.69 31.94 29.85 92.06 24.04 34.14 31.85 37.91 32.75 29.06 92.10 24.88 34.25 31.33 37.74 33.99 29.92 92.14 24.74 34.81 30.43 37.23 34.25 30.61 92.18 24.88 34.24 30.66 36.96 32.66 28.53 92.22 24.74 34.82 31.20 36.46 35.62 28.44 92.26 24.98 34.37 30.56 36.99 34.90 27.69 92.30 24.74 32.68 31.22 37.15 34.23 28.45 92.34 25.63 34.26 31.42 37.02 34.23 28.36 92.38 25.50 34.23 30.45 37.85 35.55 29.85 92.42 25.64 34.23 32.00 37.73 34.28 30.05 92.46 25.54 34.86 31.91 37.97 31.85 30.56 92.50 24.95 34.20 31.93 37.60 33.58 31.19 92.54 26.95 34.14 32.65 37.10 32.57 28.46 92.58 29.89 34.86 32.74 36.86 32.17 28.38 92.62 26.98 34.87 32.65 37.11 32.65 28.47 92.66 24.68 34.01 33.47 37.68 34.25 29.69 92.70 24.18 34.27 32.51 38.50 34.79 30.58 92.74 24.75 33.98 32.05 38.41 34.24 31.13 92.78 25.62 34.33 31.85 38.50 33.34 30.54 92.82 25.50 34.79 31.97 39.24 34.97 30.43

92.86 26.30 34.95 32.00 40.02 38.40 30.67 92.90 26.24 34.78 32.04 38.63 33.50 31.20 92.94 27.07 35.63 33.43 37.01 33.34 31.39 92.98 25.55 34.85 31.27 37.85 32.76 31.24 93.02 26.46 35.66 31.31 38.41 33.34 29.83 93.06 26.26 36.31 31.36 38.67 35.70 29.09 93.10 26.32 37.15 32.06 38.43 34.73 28.41 93.14 26.24 35.49 32.03 38.65 33.43 29.05 93.18 26.21 35.72 32.81 39.27 34.08 28.48 93.22 26.89 36.24 32.09 39.23 35.66 29.04 93.26 27.64 36.46 32.11 37.69 34.01 29.18 93.30 27.09 35.54 32.00 39.43 35.64 29.82 93.34 26.16 36.44 32.04 39.19 34.10 30.56 93.38 26.34 36.21 32.74 39.26 34.21 30.54 93.42 26.17 37.21 33.59 38.40 33.37 30.65 93.46 26.34 35.52 32.55 38.54 32.81 30.52 93.50 26.18 35.73 32.83 38.35 33.34 31.32 93.54 27.11 37.06 31.99 38.54 32.72 31.87 93.58 27.59 36.40 32.11 39.32 32.81 30.67 93.62 27.78 36.38 32.63 40.04 31.99 31.85 93.66 26.99 35.58 33.55 39.32 32.05 32.04 93.70 27.09 35.68 32.51 39.99 32.74 31.13 93.74 27.01 36.22 32.86 40.19 32.09 31.32 93.78 26.20 37.22 31.88 40.56 32.74 30.45 93.82 27.11 35.44 32.84 40.15 32.79 30.72 93.86 26.82 34.89 31.83 39.98 32.72 31.13 93.90 27.73 34.73 32.08 39.32 33.62 32.13 93.94 28.27 34.93 31.16 39.20 31.86 32.63 93.98 29.16 35.50 31.41 40.09 32.91 31.46 94.02 28.33 35.62 31.04 39.87 32.68 30.48 94.06 27.67 35.46 32.04 40.08 32.72 30.64 94.10 27.61 35.74 31.99 39.84 33.43 29.73 94.14 27.84 34.14 31.29 40.07 33.58 30.01 94.18 26.85 34.19 31.22 39.96 32.57 29.82 94.22 28.54 34.05 31.33 40.00 33.49 29.96 94.26 28.35 34.21 31.97 40.00 33.30 30.51 94.30 29.28 34.11 32.03 39.98 32.05 31.37 94.34 31.28 34.24 31.85 39.79 31.87 31.84 94.38 29.24 34.76 32.88 40.07 32.67 30.70 94.42 28.44 34.27 33.38 39.16 31.88 29.72 94.46 29.08 34.78 33.46 40.07 32.74 30.67 94.50 28.44 34.28 33.36 39.85 31.79 30.52 94.54 26.91 33.38 34.31 40.06 32.70 32.15 94.58 26.24 33.55 34.75 39.93 33.34 34.06 94.62 25.49 33.44 34.85 40.03 34.94 31.37 94.66 28.54 33.61 35.42 40.02 34.15 30.57 94.70 26.92 33.36 35.71 40.10 34.23 32.08 94.74 28.46 34.26 36.13 40.08 34.08 31.16 94.78 28.36 34.21 35.57 39.98 34.19 30.57 94.82 28.55 34.17 35.54 40.15 35.65 31.30 94.86 26.93 34.14 34.84 40.64 34.12 31.22 94.90 26.37 33.50 35.47 40.85 34.97 32.04

94.94 26.98 33.46 35.65 40.57 36.98 32.67 94.98 27.08 34.07 35.66 40.14 38.69 32.78 95.02 26.30 34.92 36.37 39.90 34.78 32.04 95.06 26.27 34.12 35.56 40.09 34.29 31.94 95.10 26.32 34.93 35.63 39.84 33.39 32.03 95.14 26.86 34.03 35.62 40.79 34.26 31.35 95.18 26.99 34.25 34.95 39.85 34.02 31.17 95.22 27.56 33.98 34.98 40.07 33.56 31.36 95.26 27.69 35.59 34.92 39.87 34.09 31.29 95.30 28.35 35.47 35.73 40.01 33.58 31.33 95.34 28.46 35.56 36.26 39.15 34.75 31.28 95.38 28.34 36.27 36.48 40.04 35.01 32.03 95.42 28.51 37.11 34.77 39.93 34.02 30.35 95.46 29.68 37.03 36.42 40.01 34.19 32.05 95.50 29.89 37.02 35.58 40.57 33.30 29.71 95.54 29.06 38.39 35.07 41.48 33.46 30.55 95.58 27.75 38.61 34.84 40.69 32.59 29.79 95.62 27.63 37.64 35.76 40.72 32.75 30.60 95.66 27.77 37.19 34.77 40.83 33.36 31.84 95.70 27.74 37.74 34.97 39.90 34.18 31.94 95.74 27.61 37.21 32.68 40.07 34.09 31.85 95.78 28.51 37.76 32.15 39.93 34.15 31.33 95.82 28.28 37.97 31.84 40.09 34.10 31.12 95.86 29.20 37.68 32.79 39.87 33.52 31.32 95.90 28.30 37.18 32.70 40.79 33.28 31.13 95.94 27.87 36.92 32.83 40.57 34.99 31.37 95.98 26.82 37.88 32.57 40.03 38.51 32.69 96.02 27.74 38.50 32.78 40.61 35.59 30.49 96.06 26.98 37.98 32.57 40.81 34.95 30.44 96.10 27.16 37.75 32.84 41.43 34.87 30.67 96.14 27.74 37.84 32.64 40.74 34.28 31.16 96.18 27.87 37.80 32.72 44.29 34.08 32.04 96.22 27.65 37.02 33.29 43.04 34.29 31.97 96.26 28.47 38.53 32.77 41.36 34.86 32.04 96.30 27.73 37.13 32.67 41.50 34.29 31.23 96.34 27.53 37.13 32.78 41.48 36.23 31.26 96.38 27.11 36.96 33.35 41.48 34.31 31.23 96.42 28.26 37.88 33.53 41.58 33.31 30.68 96.46 27.09 37.03 33.29 39.96 34.23 30.44 96.50 26.96 36.35 32.72 40.85 34.02 31.42 96.54 27.07 36.98 32.64 43.58 32.79 31.10 96.58 26.94 36.35 32.74 42.27 32.66 32.08 96.62 27.75 36.90 33.27 41.36 32.82 31.93 96.66 27.57 35.70 33.56 43.11 34.85 32.08 96.70 27.81 36.24 33.27 41.34 35.64 33.32 96.74 28.34 35.61 33.49 40.80 34.80 35.71 96.78 28.55 35.44 34.23 40.64 34.19 33.35 96.82 26.97 36.46 33.47 40.83 33.38 35.02 96.86 27.82 35.54 34.17 40.58 33.36 32.64 96.90 27.68 36.37 34.16 43.08 33.34 31.38 96.94 27.71 35.53 34.19 41.37 33.56 31.93 96.98 28.40 35.64 32.64 42.24 32.54 31.40

97.02 28.27 36.30 33.57 44.22 32.66 31.83 97.06 28.50 34.97 34.19 42.15 33.23 30.72 97.10 29.01 35.52 34.26 40.65 34.19 30.36 97.14 29.90 35.72 34.10 39.99 34.10 32.12 97.18 26.93 35.49 34.29 39.90 34.12 31.92 97.22 27.75 36.41 34.16 40.04 34.20 31.41 97.26 28.33 36.29 33.52 40.71 33.53 31.23 97.30 28.50 36.46 34.11 41.33 34.17 32.10 97.34 27.64 35.59 34.28 41.60 34.17 31.90 97.38 28.51 35.68 33.36 41.32 34.21 32.14 97.42 28.28 36.18 32.84 41.57 34.79 32.04 97.46 29.21 35.79 33.34 41.29 34.94 32.79 97.50 29.85 35.57 33.55 40.86 34.84 32.76 97.54 27.73 35.73 34.01 40.59 34.26 32.82 97.58 28.45 36.43 33.49 41.53 33.37 32.79 97.62 28.33 36.33 32.60 40.70 33.56 32.06 97.66 29.88 37.13 34.20 40.82 33.39 31.24 97.70 29.75 36.34 34.00 41.39 33.53 33.39 97.74 30.55 37.05 34.24 40.77 33.34 34.18 97.78 29.75 37.57 34.09 40.58 34.27 31.88 97.82 29.87 37.82 34.18 39.96 34.07 32.78 97.86 30.33 37.72 34.10 39.88 34.20 33.27 97.90 29.25 37.79 34.25 40.78 34.11 33.47 97.94 29.70 37.71 34.81 42.78 34.28 34.03 97.98 30.64 37.96 34.85 42.97 34.08 34.95 98.02 31.23 38.47 35.46 42.87 34.25 35.46 98.06 31.40 38.57 35.66 43.77 35.39 36.42 98.10 31.90 39.19 35.46 42.27 37.83 37.72 98.14 31.32 38.64 35.67 41.49 34.06 34.18 98.18 32.67 38.40 35.58 41.61 33.56 34.03 98.22 32.73 38.63 35.61 42.18 34.12 34.26 98.26 29.13 38.42 34.81 42.33 35.66 34.80 98.30 28.97 38.64 35.66 42.03 36.94 35.56 98.34 29.94 38.37 35.64 42.30 35.59 34.76 98.38 31.18 38.64 35.61 42.17 35.47 35.65 98.42 31.28 38.37 35.67 42.24 35.67 36.23 98.46 30.52 39.32 35.53 42.10 34.70 36.47 98.50 31.38 38.37 35.71 42.29 33.54 34.03 98.54 32.63 38.70 36.33 41.30 33.29 34.98 98.58 32.83 37.71 36.52 42.24 33.48 34.06 98.62 31.99 37.74 35.46 41.47 34.00 34.26 98.66 31.39 37.89 35.72 40.70 34.19 34.10 98.70 30.49 37.77 35.50 40.61 34.09 34.98 98.74 29.94 38.64 36.47 40.77 34.21 34.79 98.78 30.55 39.22 35.54 40.57 34.18 34.36 98.82 31.19 39.35 35.71 41.43 34.14 34.01 98.86 31.37 38.47 35.48 42.76 34.18 34.28 98.90 31.14 38.62 35.66 43.77 34.14 33.41 98.94 30.66 38.42 35.47 43.55 34.29 34.20 98.98 31.21 38.59 36.38 42.90 34.17 33.37 99.02 31.32 38.42 35.47 42.83 34.29 32.86 99.06 30.37 37.88 36.41 42.24 34.80 32.73

99.10 30.66 39.26 35.49 43.71 34.24 33.54 99.14 31.17 40.00 35.68 43.58 34.07 32.03 99.18 30.62 39.10 36.18 43.77 34.34 32.08 99.22 30.51 39.36 35.65 41.41 34.11 31.92 99.26 29.24 39.93 36.32 41.57 33.54 31.33 99.30 29.14 40.03 35.66 42.12 33.39 32.05 99.34 28.50 39.79 35.54 42.28 34.25 33.54 99.38 28.40 38.62 35.71 42.09 34.73 33.45 99.42 29.78 39.12 35.46 43.01 34.26 33.53 99.46 29.87 39.29 36.44 42.82 34.71 34.20 99.50 29.70 37.77 36.23 42.25 35.72 36.24 99.54 30.64 37.93 35.68 42.07 33.35 32.04 99.58 30.47 38.35 35.57 42.28 33.39 32.68 99.62 31.46 39.42 36.40 42.87 34.10 32.11 99.66 31.22 38.51 36.29 42.95 34.15 33.28 99.70 31.35 39.42 36.35 42.79 34.71 32.67 99.74 30.52 39.12 36.18 42.96 34.95 32.56 99.78 29.88 40.07 36.40 42.78 34.71 32.84 99.82 29.72 38.56 35.48 44.39 37.13 32.56 99.86 30.01 37.83 35.68 43.72 37.72 31.96 99.90 29.81 37.76 36.21 43.02 34.26 31.92 99.94 30.63 38.64 36.42 42.26 34.19 31.97 99.98 30.56 38.59 35.50 42.10 34.84 31.90 100.02 30.61 38.43 35.68 43.06 35.56 32.05 100.06 31.29 37.85 35.55 43.54 35.57 31.84 100.10 31.85 37.69 36.42 43.03 35.75 32.81 100.14 30.61 39.35 36.31 43.62 35.47 31.86 100.18 30.51 37.75 36.38 44.45 35.73 32.86 100.22 31.23 37.11 37.16 44.30 35.50 32.64 100.26 32.66 37.76 36.35 43.70 34.25 34.15 100.30 33.53 37.16 37.14 44.36 34.84 33.38 100.34 31.83 37.07 37.14 44.45 35.03 33.55 100.38 30.66 37.89 37.14 44.98 34.81 33.30 100.42 30.49 37.60 36.41 45.09 35.70 32.87 100.46 31.41 37.88 37.16 45.77 36.32 33.30 100.50 31.83 37.68 37.01 45.93 36.40 34.35 100.54 32.81 38.56 37.17 45.78 36.22 34.12 100.58 32.75 39.19 36.94 46.75 36.44 32.09 100.62 31.94 39.35 37.88 45.92 35.53 31.99 100.66 31.99 38.48 37.77 45.15 35.66 33.54 100.70 30.43 37.97 37.93 45.31 35.44 34.03 100.74 30.55 39.12 37.67 45.16 35.67 34.33 100.78 31.20 39.44 37.89 44.53 35.47 33.47 100.82 31.32 38.48 38.45 43.57 36.39 34.94 100.86 31.12 38.63 37.93 43.77 36.12 34.94 100.90 30.62 37.77 36.97 43.57 36.43 34.87 100.94 30.45 38.55 37.11 43.72 36.30 35.67 100.98 31.40 39.36 37.01 43.51 36.33 35.72 101.02 31.97 39.24 37.15 44.49 36.32 34.90 101.06 32.82 40.79 36.24 44.25 36.32 34.85 101.10 32.78 40.62 37.89 44.45 35.47 34.21 101.14 31.97 40.72 37.72 45.06 35.63 34.81

101.18 31.37 39.79 37.14 44.54 36.17 34.28 101.22 31.79 39.37 36.98 43.56 36.39 35.40 101.26 31.30 39.86 37.13 43.65 36.86 37.84 101.30 31.93 39.20 36.90 43.52 36.37 32.65 101.34 32.00 39.13 37.84 44.45 36.31 34.12 101.38 31.19 39.32 38.46 43.61 37.11 34.00 101.42 29.88 38.32 38.54 43.78 36.37 34.19 101.46 29.71 38.61 37.63 42.98 35.65 34.78 101.50 29.18 39.11 37.08 42.95 36.38 34.96 101.54 29.04 39.34 37.67 42.29 36.41 34.11 101.58 29.19 39.15 37.82 42.84 35.58 34.92 101.62 30.47 39.26 37.79 43.78 35.67 34.86 101.66 35.04 38.46 37.83 43.55 34.92 34.95 101.70 33.48 38.57 37.71 44.53 34.82 34.08 101.74 30.54 38.45 37.80 43.55 35.03 34.23 101.78 31.27 38.65 36.89 43.70 34.18 33.97 101.82 31.16 38.47 37.84 43.62 34.28 34.25 101.86 31.32 38.53 38.59 43.71 34.87 33.28 101.90 29.78 38.55 38.59 43.64 34.99 33.49 101.94 29.81 37.85 38.61 43.08 37.67 33.28 101.98 29.77 37.63 37.54 43.62 36.46 32.81 102.02 29.18 37.88 37.88 44.42 36.27 33.34 102.06 28.94 38.50 37.76 42.86 37.13 32.79 102.10 29.91 38.62 37.90 43.71 37.09 32.56 102.14 29.05 38.41 37.65 43.70 37.16 32.06 102.18 29.26 38.59 37.90 43.71 35.52 32.63 102.22 29.03 39.22 36.93 43.69 35.64 32.83 102.26 30.63 39.37 37.96 44.32 34.78 33.36 102.30 30.47 38.47 36.96 44.54 35.68 33.52 102.34 30.68 38.70 36.40 43.50 36.20 34.05 102.38 30.53 37.74 36.98 43.04 37.08 35.01 102.42 29.85 38.69 37.11 42.86 36.98 34.08 102.46 29.88 39.15 37.72 42.28 37.10 32.85 102.50 28.99 40.12 37.97 42.09 36.21 32.66 102.54 28.40 39.31 37.64 42.25 37.16 33.59 102.58 29.05 39.34 38.58 42.84 36.20 33.40 102.62 28.57 39.16 37.75 43.71 37.08 32.84 102.66 28.40 38.57 37.89 42.80 39.10 33.28 102.70 28.50 38.56 36.91 42.27 38.59 33.53 102.74 28.97 38.54 38.54 42.75 36.26 33.44 102.78 29.22 38.57 38.38 42.99 35.66 33.46 102.82 28.37 38.49 37.92 42.79 35.45 32.00 102.86 28.51 38.54 37.72 42.98 35.68 33.43 102.90 28.32 38.45 37.17 42.87 35.56 34.18 102.94 28.50 38.57 37.69 43.72 34.90 33.35 102.98 29.12 39.15 37.87 45.25 35.52 33.54 103.02 29.15 38.57 38.29 44.36 36.43 32.59 103.06 29.79 38.37 38.56 43.04 36.16 33.47 103.10 33.43 39.24 38.38 42.89 36.32 33.28 103.14 29.16 39.85 38.61 42.28 36.26 33.41 103.18 29.71 40.86 36.94 42.09 35.72 34.01 103.22 29.85 39.13 37.82 42.29 36.30 34.16

103.26 29.03 39.91 37.71 41.37 36.39 34.88 103.30 29.86 42.14 37.76 41.49 36.97 35.65 103.34 29.68 39.35 37.73 42.06 36.35 36.96 103.38 29.89 39.90 38.59 42.24 36.25 35.68 103.42 29.76 40.09 38.50 42.14 36.46 36.25 103.46 29.91 39.83 38.58 42.24 36.20 35.66 103.50 31.19 40.09 38.01 42.12 36.39 36.20 103.54 31.47 39.83 37.00 42.24 36.23 36.42 103.58 31.12 39.31 37.87 42.10 36.32 35.54 103.62 29.89 40.71 38.45 42.91 36.25 35.71 103.66 29.18 40.02 38.66 42.15 37.81 35.47 103.70 29.03 40.66 39.11 42.15 39.85 36.49 103.74 29.09 39.38 38.63 42.95 39.37 36.88 103.78 28.95 39.13 37.66 42.04 39.13 37.21 103.82 29.25 39.28 38.00 43.05 40.07 36.32 103.86 29.73 40.66 36.90 42.81 39.91 35.05 103.90 29.78 40.06 37.19 43.09 40.73 35.57 103.94 28.27 40.65 37.05 42.88 39.23 35.73 103.98 28.42 40.12 36.40 41.61 39.29 36.33 104.02 29.00 40.63 37.00 42.10 38.49 34.98 104.06 28.54 39.44 38.66 41.51 39.28 35.59 104.10 28.32 39.08 38.42 42.06 39.23 35.68 104.14 28.55 39.43 37.90 42.22 39.31 34.18 104.18 28.30 40.00 38.35 41.26 39.34 34.11 104.22 28.55 39.38 37.91 42.30 38.54 33.47 104.26 27.65 39.88 37.72 42.86 37.94 33.30 104.30 28.36 39.39 37.83 42.88 37.77 34.18 104.34 27.73 40.71 37.67 42.12 38.58 34.73 104.38 28.27 40.09 37.84 42.93 39.22 34.87 104.42 28.44 39.87 38.41 42.05 37.23 36.30 104.46 28.32 40.77 37.92 42.88 36.27 34.84 104.50 28.46 40.04 37.79 40.62 35.76 33.39 104.54 28.24 39.99 38.66 41.50 36.16 34.24 104.58 28.47 39.96 37.72 41.36 35.74 33.39 104.62 29.09 39.99 37.87 41.43 34.80 32.81 104.66 28.54 40.04 37.76 42.30 34.97 31.97 104.70 28.37 39.28 37.88 42.21 35.56 32.04 104.74 28.56 40.04 37.72 43.05 35.73 32.63 104.78 27.58 39.95 37.19 43.54 35.52 33.55 104.82 27.83 39.34 37.63 42.26 35.73 33.35 104.86 29.18 39.93 38.57 43.67 35.56 34.24 104.90 28.26 40.00 36.92 44.49 34.97 34.05 104.94 28.47 41.39 37.84 44.31 34.82 34.24 104.98 28.95 40.65 37.65 45.22 34.97 34.06 105.02 30.64 40.80 37.79 44.25 34.81 34.28 105.06 29.79 40.04 37.75 43.79 34.92 34.79 105.10 30.61 39.27 37.83 43.64 34.12 35.81 111.45 26.85 36.99 35.75 40.15 34.89 33.61 111.49 26.41 37.15 34.76 39.28 34.02 31.87 111.53 26.87 35.67 34.99 39.90 34.99 32.10 111.57 27.81 36.29 35.68 40.10 36.32 33.38

111.61 27.66 37.10 34.75 40.64 34.92 36.43 111.65 27.52 37.65 34.93 40.79 35.55 35.62 111.69 28.50 37.94 34.75 40.65 35.04 36.22 111.73 27.63 37.66 34.92 42.25 34.85 35.04 111.77 27.12 36.97 34.80 41.48 34.92 34.81 111.81 27.76 37.06 34.96 41.33 34.89 34.94 111.85 28.23 37.03 34.88 42.95 35.49 34.81 111.89 27.77 37.90 35.48 42.06 35.70 35.03 111.93 28.31 38.38 35.63 41.57 36.17 34.75 111.97 27.79 37.15 35.54 42.21 35.78 35.74 112.01 27.69 37.13 35.71 42.99 36.30 35.63 112.05 28.22 36.98 36.25 42.88 36.38 34.16 112.09 28.46 36.39 36.35 42.09 36.34 34.19 112.13 28.33 37.66 35.70 42.99 36.17 34.07 112.17 28.47 37.91 35.59 43.55 36.33 33.48 112.21 27.78 38.58 35.64 44.60 36.17 33.40 112.25 27.58 37.73 34.79 44.46 36.43 32.85 112.29 27.78 37.11 35.78 43.74 36.25 32.67 112.33 27.59 37.64 35.65 43.72 35.71 32.86 112.37 27.84 37.92 35.48 42.83 36.37 32.69 112.41 26.96 39.13 34.95 43.03 37.71 32.14 112.45 28.30 38.50 35.53 43.57 39.32 31.24 112.49 28.48 38.54 35.72 43.04 40.67 32.57 112.53 27.64 38.47 36.32 43.58 40.04 32.79 112.57 27.81 37.88 35.73 44.44 37.02 32.65 112.61 28.44 38.39 34.98 44.38 36.47 33.48 112.65 28.27 37.88 34.81 44.29 37.07 34.80 112.69 28.50 37.72 35.63 45.26 37.61 37.23 112.73 27.58 37.66 36.18 44.26 37.08 34.09 112.77 29.26 37.76 35.74 43.79 37.00 33.47 112.81 29.03 38.46 35.57 43.48 38.49 33.48 112.85 28.94 40.82 36.24 42.98 40.02 33.37 112.89 29.26 39.92 36.41 43.71 42.96 32.75 112.93 29.02 40.02 36.31 42.81 39.26 31.92 112.97 30.00 39.34 37.21 43.05 37.16 32.10 113.01 29.01 39.15 36.96 42.84 36.34 33.29 113.05 28.25 38.57 37.18 43.74 36.91 34.23 113.09 30.00 39.22 36.42 44.37 37.82 31.99 113.13 29.01 40.17 36.26 44.34 38.41 32.14 113.17 29.28 41.42 36.34 44.44 37.99 33.50 113.21 29.90 38.45 35.49 44.39 38.47 32.52 113.25 30.43 38.67 36.47 44.46 39.29 32.79 113.29 29.83 39.06 35.63 45.12 37.14 33.41 113.33 29.09 39.42 35.56 45.26 37.65 33.47 113.37 29.95 39.94 36.41 45.11 38.54 34.78 113.41 30.49 40.00 36.98 44.40 39.14 35.72 113.45 31.84 38.56 37.02 45.14 40.01 35.54 113.49 31.26 39.15 36.98 45.73 39.86 35.01 113.53 30.39 38.59 36.51 45.30 40.14 35.56 113.57 32.10 39.21 36.29 45.09 38.48 34.88 113.61 31.31 40.14 36.27 45.96 39.93 34.95 113.65 31.16 39.31 36.40 45.20 39.31 35.45

113.69 31.95 41.39 35.64 45.75 39.22 35.58 113.73 30.47 40.07 36.44 45.93 39.40 35.53 113.77 30.67 39.86 37.68 45.74 39.18 37.09 113.81 31.23 40.09 37.96 46.79 38.70 37.80 113.85 32.59 39.95 37.79 45.73 39.30 36.48 113.89 32.67 40.80 37.66 45.95 39.12 34.92 113.93 32.68 39.98 37.83 45.22 39.37 34.27 113.97 33.56 39.19 38.41 45.74 39.18 34.17 114.01 30.37 39.24 37.19 45.20 39.36 33.38 114.05 31.32 39.14 36.94 45.77 39.98 34.20 114.09 31.29 39.45 37.88 46.07 40.04 33.36 114.13 30.49 39.19 37.90 45.15 42.21 33.48 114.17 30.64 38.41 36.90 46.57 44.31 33.32 114.21 31.22 39.22 37.81 46.61 39.96 32.75 114.25 30.49 39.87 37.71 46.58 39.93 33.35 114.29 30.64 40.11 37.87 46.71 40.02 33.55 114.33 30.47 39.85 37.80 47.25 39.87 34.80 114.37 29.89 40.00 40.07 48.29 40.85 35.68 114.41 29.70 40.74 38.58 45.78 40.67 35.59 114.45 30.58 39.86 37.69 45.89 40.73 36.99 114.49 29.94 41.50 37.85 46.01 40.70 36.35 114.53 30.43 40.62 37.69 45.84 39.90 36.32 114.57 29.89 40.08 38.67 46.65 40.82 36.39 114.61 29.77 39.18 38.61 47.32 40.61 35.45 114.65 29.18 39.95 38.40 47.47 41.56 34.96 114.69 29.08 40.71 38.56 47.45 42.10 35.55 114.73 29.85 39.86 39.22 48.04 42.32 35.70 114.77 29.94 40.83 37.91 46.59 41.36 34.72 114.81 31.12 40.70 37.08 47.39 41.58 34.97 114.85 32.08 40.08 37.15 46.68 42.93 35.56 114.89 32.08 41.45 37.84 46.43 41.41 36.35 114.93 31.23 39.98 38.40 48.21 40.81 35.61 114.97 32.04 40.83 38.55 47.32 39.86 34.82 115.01 32.69 40.58 38.42 48.03 40.86 34.18 115.05 31.35 40.10 39.34 48.84 39.96 33.31 115.09 31.30 41.48 39.27 50.18 40.87 33.55 115.13 31.93 41.35 38.47 50.42 40.75 34.16 115.17 32.83 41.57 39.28 49.54 40.56 35.68 115.21 32.56 41.30 39.95 49.64 40.03 35.62 115.25 32.75 42.34 38.65 48.93 41.42 34.23 115.29 32.78 42.18 39.19 48.08 41.44 34.97 115.33 33.36 42.82 38.64 47.32 42.12 36.20 115.37 32.77 43.06 39.99 46.58 41.59 35.68 115.41 31.93 42.18 39.13 46.76 40.02 34.73 115.45 32.66 43.67 39.31 48.02 40.75 33.50 115.49 32.04 42.90 38.39 48.32 39.95 34.81 115.53 32.59 43.03 39.39 47.33 39.21 35.01 115.57 33.54 42.91 39.26 47.94 40.78 34.93 115.61 33.31 42.82 38.48 48.14 41.35 33.55 115.65 33.52 44.39 39.24 48.82 42.36 34.20 115.69 34.93 43.56 37.77 49.00 41.28 34.10 115.73 32.65 43.72 37.10 48.64 41.45 34.92

115.77 33.46 43.51 37.00 48.25 39.32 34.79 115.81 33.36 44.52 37.94 48.15 39.93 35.61 115.85 33.48 41.51 37.13 50.19 40.74 35.58 115.89 32.75 41.41 37.61 49.65 40.69 33.49 115.93 33.37 42.29 37.13 48.77 40.88 33.37 115.97 33.54 42.12 37.03 49.02 40.87 34.33 116.01 32.69 44.53 37.81 50.30 41.39 34.19 116.05 33.49 43.72 38.38 51.02 40.71 34.16 116.09 34.19 41.95 37.97 50.47 40.69 34.19 116.13 33.40 42.29 37.92 49.63 40.75 33.29 116.17 33.55 43.46 37.64 49.69 40.61 34.25 116.21 31.93 43.10 37.77 48.75 41.67 34.84 116.25 32.82 42.19 37.73 49.01 42.83 36.42 116.29 32.69 42.75 37.17 48.12 44.44 37.00 116.33 32.68 43.66 36.96 48.75 44.39 38.63 116.37 33.44 45.84 37.75 50.45 43.58 36.97 116.41 33.34 45.18 37.81 51.07 42.97 36.32 116.45 32.83 44.34 38.43 51.11 42.03 34.18 116.49 33.49 44.51 40.01 50.97 41.59 34.03 116.53 34.02 43.66 40.67 50.56 41.48 33.47 116.57 32.78 42.03 40.17 49.59 41.39 33.36 116.61 34.08 42.93 40.00 49.48 42.25 34.23 116.65 33.56 42.79 37.74 48.17 42.18 34.77 116.69 35.59 43.82 38.56 48.02 42.15 34.27 116.73 34.71 44.39 39.27 48.15 42.10 33.37 116.77 33.48 45.08 39.34 47.39 42.27 33.53 116.81 32.57 45.11 39.18 48.24 42.78 34.15 116.85 32.86 44.25 40.16 48.05 43.80 33.30 116.89 32.78 43.76 39.19 48.71 43.71 34.85 116.93 33.27 42.81 39.78 46.73 46.53 34.84 116.97 34.17 42.90 38.56 45.79 45.89 34.97 117.01 35.56 43.76 39.05 46.71 45.74 34.72 117.05 35.68 43.58 40.09 45.78 46.67 34.96 117.09 35.62 43.02 39.86 45.29 45.84 34.77 117.13 36.96 42.10 40.83 45.84 45.95 34.33 117.17 36.40 43.04 40.04 46.45 45.09 33.41 117.21 36.23 42.94 39.87 46.76 45.05 35.61 117.25 36.49 41.97 40.81 47.29 44.52 35.74 117.29 36.32 42.99 39.80 47.52 44.36 34.81 117.33 38.45 42.10 38.63 46.59 43.74 34.92 117.37 37.79 42.27 37.67 47.44 43.55 34.05 117.41 36.94 42.93 37.15 47.38 43.79 34.26 117.45 37.19 42.26 37.77 47.19 44.39 33.41 117.49 37.10 42.96 36.26 47.37 44.34 33.58 117.53 37.01 43.57 36.42 46.53 44.49 33.46 117.57 37.03 42.20 36.97 46.72 43.54 33.54 117.61 36.90 42.03 37.18 47.33 43.81 32.72 117.65 38.71 42.34 36.39 46.67 43.58 33.27 117.69 39.91 41.45 36.39 46.61 43.05 33.54 117.73 39.13 41.28 37.13 47.25 42.97 34.77 117.77 37.83 42.22 39.19 47.51 42.83 34.90 117.81 36.94 41.99 41.56 47.27 42.22 34.78

117.85 37.16 43.73 38.43 46.69 42.11 35.68 117.89 37.73 42.03 37.88 45.88 42.18 35.48 117.93 37.60 41.48 38.49 45.97 41.36 36.48 117.97 38.65 41.48 37.72 46.00 41.57 34.90 118.01 39.11 41.32 37.90 45.71 41.52 32.57 118.05 39.46 42.26 37.03 46.80 41.37 33.56 118.09 38.42 43.59 37.18 46.51 42.28 33.37 118.13 39.12 43.79 37.03 46.67 41.37 33.47 118.17 39.36 42.82 37.17 47.31 42.96 33.35 118.21 38.34 42.82 37.76 47.46 42.84 33.61 118.25 36.41 43.02 37.69 46.66 42.27 34.14 118.29 37.87 42.22 37.81 46.46 42.27 34.23 118.33 37.73 41.52 36.97 46.71 44.99 33.54 118.37 37.13 42.13 37.15 46.59 42.98 33.36 118.41 37.67 42.28 36.93 47.51 42.04 33.48 118.45 37.18 44.40 37.88 48.07 42.27 34.84 118.49 39.21 44.39 37.87 49.52 42.87 35.67 118.53 39.12 43.77 37.63 49.72 43.03 34.81 118.57 37.85 43.58 38.55 50.24 41.43 34.99 118.61 37.67 43.04 37.66 51.19 41.30 34.78 118.65 36.46 42.99 37.90 51.03 42.25 34.95 118.69 36.30 42.03 38.51 51.27 44.27 34.25 118.73 36.96 42.30 38.41 51.10 43.02 33.99 118.77 37.79 42.83 37.88 49.56 42.13 35.03 118.81 37.73 43.05 36.99 48.17 41.61 34.81 118.85 37.93 44.38 38.56 48.80 42.18 34.92 118.89 37.02 45.00 38.49 49.66 42.21 34.78 118.93 36.44 43.05 38.66 48.84 42.30 35.71 118.97 37.11 42.79 37.10 49.83 42.12 35.59 119.01 37.67 43.06 38.40 48.82 45.20 36.40 119.05 37.88 42.96 38.64 49.57 45.84 35.67 119.09 38.49 43.02 39.20 48.14 43.76 36.24 119.13 38.59 42.94 39.37 48.05 44.33 37.76 119.17 38.62 43.61 38.37 47.45 44.32 37.74 119.21 37.65 43.01 38.65 47.25 43.82 36.47 119.25 38.62 42.71 38.50 48.22 42.10 34.77 119.29 38.40 42.95 38.38 48.91 42.96 34.93 119.33 38.59 42.95 39.31 49.44 43.62 35.53 119.37 39.96 42.79 38.42 48.92 42.37 36.38 119.41 39.14 42.91 37.91 47.23 42.06 36.35 119.45 38.55 42.80 38.41 48.28 42.27 36.92 119.49 36.94 43.78 39.16 47.34 42.22 36.29 119.53 36.39 45.18 39.31 46.69 42.12 35.56 119.57 37.88 42.87 39.88 46.73 41.50 35.59 119.61 37.66 42.98 40.08 45.77 42.81 36.25 119.65 37.09 42.74 39.23 45.91 43.09 36.57 119.69 37.72 43.78 38.70 45.82 42.15 35.58 119.73 37.92 43.58 39.24 45.95 42.27 35.57 119.77 37.85 43.69 39.20 45.91 42.26 35.61 119.81 38.41 43.72 39.42 46.61 42.71 35.53 119.85 39.32 43.61 39.10 46.72 42.97 34.96 119.89 39.20 43.72 39.45 47.25 42.10 34.76

119.93 39.42 43.56 39.20 46.67 43.78 34.96 119.97 37.83 43.78 39.31 46.52 44.23 34.82 120.01 36.20 43.67 38.91 46.76 43.81 34.97 120.05 35.66 43.54 39.14 47.26 42.90 34.90 120.09 36.21 44.41 38.62 48.09 42.78 35.02 120.13 35.80 44.27 37.64 48.89 43.74 35.66 120.17 36.41 44.54 37.90 48.78 43.65 35.48 120.21 36.14 44.39 38.58 48.94 45.29 35.02 120.25 37.13 44.36 38.37 48.75 44.31 34.09 120.29 37.65 43.74 38.64 49.00 43.86 34.25 120.33 37.92 44.39 38.41 48.17 44.53 34.07 120.37 37.05 43.76 38.56 48.07 43.65 34.98 120.41 36.37 43.51 38.49 47.43 43.67 35.59 120.45 35.72 43.79 37.91 48.18 43.61 36.32 120.49 36.93 42.98 38.61 48.22 44.51 37.91 120.53 37.93 43.61 37.64 48.73 45.06 35.52 120.57 37.90 43.79 38.56 48.98 45.30 35.57 120.61 37.60 43.59 38.41 48.01 45.11 37.08 120.65 38.54 43.78 38.70 48.11 45.19 37.15 120.69 36.99 43.66 38.55 47.53 45.88 36.20 120.73 37.16 43.51 38.49 48.08 45.74 35.78 120.77 37.01 43.62 37.81 47.53 46.00 35.55 120.81 38.34 43.51 38.39 47.25 47.17 34.99 120.85 38.61 43.76 38.55 47.54 48.98 35.73 120.89 38.39 44.34 38.48 47.43 44.34 34.73 120.93 37.85 44.42 37.90 47.94 42.30 35.02 120.97 35.63 44.39 37.88 48.25 42.90 36.22 121.01 36.16 44.30 38.45 48.79 43.52 36.40 121.05 36.30 44.47 38.59 49.78 43.10 35.53 121.09 36.16 43.56 38.43 50.31 42.79 36.54 121.13 36.46 43.74 38.58 50.47 43.65 35.54 121.17 37.11 43.67 38.55 50.41 42.87 35.74 121.21 37.63 44.30 38.62 48.00 43.10 37.03 121.25 40.10 44.57 38.47 48.08 42.19 35.49 121.29 39.88 44.27 37.67 48.07 42.95 34.26 121.33 40.87 44.83 37.87 48.96 42.25 34.78 121.37 38.47 44.99 38.39 48.61 41.39 34.92 121.41 37.64 45.12 37.93 48.89 41.50 34.73 121.45 37.87 44.40 38.49 48.89 42.09 34.93 121.49 36.17 45.00 38.58 48.68 43.05 35.56 121.53 36.42 44.41 38.51 47.38 42.75 35.67 121.57 37.11 45.04 38.37 46.53 43.01 37.06 121.61 36.85 45.22 38.64 48.29 42.18 37.79 121.65 36.39 45.20 39.16 48.91 42.03 34.92 121.69 36.99 44.94 38.61 48.00 42.89 35.54 121.73 37.17 44.47 38.61 48.87 42.09 34.87 121.77 36.37 44.36 37.68 48.84 43.02 35.48 121.81 36.20 44.52 37.96 48.91 42.78 35.75 121.85 36.46 45.19 38.47 48.82 44.51 35.55 121.89 38.38 44.26 38.59 48.96 46.59 36.48 121.93 37.91 44.51 38.40 48.17 44.26 36.26 121.97 37.16 45.08 38.67 47.98 42.28 35.56

122.01 36.97 44.52 38.51 48.11 42.78 35.66 122.05 37.72 44.37 39.92 48.05 43.11 35.54 122.09 37.01 44.46 38.58 48.95 43.55 36.34 122.13 37.18 44.36 39.18 48.79 43.81 36.97 122.17 36.33 44.37 38.63 48.94 44.42 37.15 122.21 36.20 43.74 39.16 48.93 44.16 38.54 122.25 36.34 44.26 38.50 48.74 46.03 37.84 122.29 36.90 44.48 38.58 48.91 44.25 36.24 122.33 37.15 44.44 39.05 48.04 43.82 37.06 122.37 36.34 44.22 39.37 47.48 43.55 37.85 122.41 36.21 44.49 39.12 48.08 42.97 37.61 122.45 37.09 44.29 39.35 47.51 42.95 37.90 122.49 37.68 43.84 39.30 48.19 42.75 36.96 122.53 38.00 44.32 39.12 48.72 42.14 37.14 122.57 39.32 45.08 39.34 48.15 42.15 36.20 122.61 38.40 45.13 38.42 46.58 43.02 37.14 122.65 37.85 45.05 38.64 47.51 42.84 37.00 122.69 37.65 44.44 38.42 47.36 43.13 36.39 122.73 37.17 43.59 37.68 47.27 42.89 36.39 122.77 36.29 43.71 38.61 48.15 42.79 35.44 122.81 36.18 43.72 38.48 48.03 43.63 35.58 122.85 36.40 43.62 38.58 48.98 43.52 36.99 122.89 36.17 43.79 38.48 48.74 43.74 37.18 122.93 37.22 43.55 38.69 48.29 42.87 36.21 122.97 38.62 43.81 38.46 49.63 41.57 35.74 123.01 35.45 43.66 38.39 49.50 42.22 35.58 123.05 36.43 43.51 39.38 49.00 41.33 36.37 123.09 36.26 43.64 39.18 48.74 41.51 36.40 123.13 35.74 43.59 39.32 49.06 41.47 35.49 123.17 35.68 43.82 39.16 48.86 41.56 34.88 123.21 34.02 44.29 39.34 50.51 41.29 36.29 123.25 34.98 44.29 38.61 48.94 42.35 34.92 123.29 35.55 44.54 38.40 47.25 43.57 35.57 123.33 35.72 43.54 37.93 47.45 42.10 35.80 123.37 36.46 44.53 38.43 47.25 41.51 37.05 123.41 35.48 43.65 38.63 47.44 42.89 37.05 123.45 35.66 44.38 39.18 47.26 42.30 36.47 123.49 35.54 42.90 38.59 46.65 41.40 35.49 123.53 36.43 42.86 38.58 47.34 41.59 36.34 123.57 34.86 43.82 38.47 46.66 41.45 40.73 123.61 34.73 43.58 38.59 45.97 41.33 37.88 123.65 34.93 43.02 38.45 45.81 41.55 35.53 123.69 36.27 43.61 37.90 45.25 40.62 35.75 123.73 36.41 44.34 37.84 45.89 41.53 35.63 123.77 35.58 42.27 37.69 45.11 40.65 36.94 123.81 36.25 42.04 38.55 45.09 41.55 37.81 123.85 35.67 42.32 39.20 45.09 42.19 37.74 123.89 36.23 42.14 38.61 45.26 42.13 38.61 123.93 36.48 42.79 38.34 45.81 42.17 39.83 123.97 37.11 42.27 38.56 46.04 41.45 39.38 124.01 38.40 42.10 38.58 45.15 41.53 39.95 124.05 38.65 42.32 39.18 45.22 41.29 40.09

124.09 36.96 41.40 39.29 45.94 41.58 37.79 124.13 36.49 42.28 39.14 45.11 41.39 36.91 124.17 34.89 41.49 39.42 45.23 42.25 36.38 124.21 34.75 42.07 38.53 45.04 42.18 36.99 124.25 34.26 42.30 39.07 46.71 41.30 37.85 124.29 34.80 42.05 39.28 46.62 41.53 37.77 124.33 35.02 41.52 38.47 45.81 42.13 37.91 124.37 34.80 41.53 38.58 45.15 41.52 39.23 124.41 35.56 41.29 37.75 45.04 41.50 38.61 124.45 35.58 42.32 37.88 45.29 41.48 40.04 124.49 36.25 41.35 37.87 45.08 40.73 39.79 124.53 37.11 41.59 37.63 46.02 40.62 39.35 124.57 35.58 41.43 37.84 45.97 41.57 39.76 124.61 35.53 41.40 38.47 45.01 40.70 40.14 124.65 35.55 41.51 38.63 45.18 41.60 40.59 124.69 37.75 41.35 37.75 45.06 41.48 40.83 124.73 35.72 41.48 37.73 45.31 42.09 39.22 124.77 35.54 42.13 37.08 45.20 42.21 38.50 124.81 36.40 42.30 36.99 45.88 42.13 37.79 124.85 37.10 41.49 37.22 45.92 41.56 37.07 124.89 37.67 41.34 37.76 45.00 39.90 37.83 124.93 37.15 40.75 39.38 45.18 40.83 37.56 124.97 36.26 40.61 37.87 44.30 40.70 37.14 125.01 35.54 41.61 37.64 44.60 40.64 37.02 125.05 35.63 40.59 37.91 44.37 40.74 37.21 125.09 34.81 39.82 36.99 45.87 39.85 37.83 125.13 34.99 40.75 37.89 46.74 40.02 38.47 125.17 34.81 40.57 37.74 46.59 39.87 38.54 125.21 35.63 40.78 37.87 45.92 40.15 38.33 125.25 35.66 40.71 37.75 45.73 39.12 38.63 125.29 34.80 40.70 38.48 46.79 38.63 38.40 125.33 35.04 40.82 37.79 45.07 39.29 38.61 125.37 35.58 39.84 37.64 44.37 41.28 38.51 125.41 35.65 40.80 37.92 44.48 40.82 37.88 125.45 34.26 41.33 37.68 43.52 39.78 38.56 125.49 34.82 41.49 37.73 43.01 40.10 38.38 125.53 35.03 40.73 37.82 42.89 39.96 37.07 125.57 34.86 40.66 37.76 43.08 39.24 36.98 125.61 34.93 40.78 37.89 43.67 39.32 37.21 125.65 34.95 40.71 36.97 43.44 38.43 36.26 132.00 31.12 36.38 33.28 34.88 33.46 30.65 132.04 29.90 34.84 32.74 34.00 32.65 30.55 132.08 29.85 34.84 32.59 34.31 32.77 31.85 132.12 29.72 35.68 34.25 34.14 32.57 32.69 132.16 29.90 34.78 33.46 34.76 32.08 31.24 132.20 29.85 34.77 34.06 35.73 32.04 30.58 132.24 29.06 34.99 34.28 34.75 31.86 31.81 132.28 29.23 34.79 34.24 34.97 32.78 32.83 132.32 29.09 34.90 34.05 34.87 32.65 32.76 132.36 29.86 34.95 34.96 35.49 33.52 32.63 132.40 29.10 34.69 34.73 35.66 32.77 33.54 132.44 29.56 34.99 34.95 36.27 32.61 33.32

132.48 29.94 34.96 34.24 36.48 33.47 33.53 132.52 29.90 35.53 34.70 36.39 32.56 32.77 132.56 29.78 35.74 33.56 36.26 32.82 31.93 132.60 29.92 35.54 34.24 35.01 33.34 32.09 132.64 29.18 34.75 33.30 35.52 34.01 31.87 132.68 28.96 35.01 34.17 35.67 34.16 31.42 132.72 31.33 34.86 33.35 36.37 34.12 31.35 132.76 29.10 34.84 33.26 36.31 34.95 31.84 132.80 29.23 34.95 32.68 36.41 34.17 31.21 132.84 29.14 34.10 33.35 36.27 32.68 31.94 132.88 29.73 34.90 33.55 37.06 33.50 32.85 132.92 29.97 34.92 34.90 36.33 33.34 33.36 132.96 29.89 34.79 34.79 36.37 33.55 34.32 133.00 29.06 35.75 34.25 36.39 33.40 37.09 133.04 29.97 36.34 34.02 36.29 33.61 35.46 133.08 29.11 34.82 34.05 36.43 34.19 32.73 133.12 29.03 35.05 33.50 36.31 34.76 31.88 133.16 28.50 35.63 34.06 36.31 34.94 32.18 133.20 29.12 35.48 33.44 36.42 34.08 31.20 133.24 29.01 35.03 33.48 36.17 34.24 31.19 133.28 29.11 34.93 34.08 36.48 34.21 31.42 133.32 29.00 34.69 34.29 35.65 32.61 30.44 133.36 30.06 34.99 34.17 36.33 32.72 31.37 133.40 29.95 35.56 34.02 37.16 32.57 31.87 133.44 29.67 34.79 34.28 36.13 35.06 32.05 133.48 29.22 35.64 34.19 36.39 34.20 32.08 133.52 29.15 35.50 33.29 35.72 33.99 31.82 133.56 29.05 34.93 34.27 35.48 35.65 30.63 133.60 29.23 35.72 34.08 35.74 34.71 30.40 133.64 28.99 36.96 34.32 35.47 34.32 30.61 133.68 29.05 35.74 34.94 36.41 32.73 31.24 133.72 29.18 36.34 36.31 36.33 32.61 30.53 133.76 29.09 35.58 35.74 36.29 34.20 30.65 133.80 29.97 36.44 34.84 36.43 34.08 30.51 133.84 30.58 37.05 33.97 36.26 34.98 29.94 133.88 30.54 36.24 34.98 35.47 34.89 30.39 133.92 30.04 36.47 35.53 34.93 32.73 31.36 133.96 29.16 36.29 34.95 34.81 33.45 31.24 134.00 29.02 36.16 34.90 35.73 33.36 31.26 134.04 27.77 37.13 35.58 35.55 33.50 31.37 134.08 29.81 37.71 35.01 34.75 33.39 31.85 134.12 29.09 37.66 34.96 34.90 34.18 32.82 134.16 29.13 37.87 34.80 35.55 36.33 32.77 134.20 29.04 37.69 34.93 35.76 39.93 31.79 134.24 29.26 38.56 34.73 34.95 39.29 32.00 134.28 29.18 37.71 34.69 34.77 33.36 31.95 134.32 27.65 37.65 34.92 34.95 32.79 32.08 134.36 27.08 37.17 34.76 34.86 32.74 30.51 134.40 27.66 37.06 35.03 35.76 33.34 32.00 134.44 28.26 37.02 34.94 35.61 34.27 31.27 134.48 28.50 37.06 35.52 35.55 34.14 31.23 134.52 28.36 37.06 35.03 35.70 34.99 32.00

134.56 29.80 36.84 34.87 35.54 36.37 31.95 134.60 29.21 37.10 34.78 35.78 34.06 31.38 134.64 29.02 36.26 34.25 35.54 32.05 31.23 134.68 30.01 36.30 34.10 36.12 33.29 31.20 134.72 29.83 37.13 34.90 36.33 34.29 31.32 134.76 29.82 36.97 34.21 36.24 34.94 31.17 134.80 30.64 37.23 34.06 36.48 34.75 31.39 134.84 30.46 36.35 34.26 35.63 34.88 32.00 134.88 30.45 36.25 34.21 36.23 36.98 32.70 134.92 30.63 36.47 33.91 36.41 40.11 31.96 134.96 29.03 36.40 34.17 36.22 37.08 31.21 135.00 29.10 35.50 32.66 37.17 33.27 31.29 135.04 29.08 35.75 32.79 37.15 34.23 31.08 135.08 29.72 34.19 32.81 36.25 34.01 31.38 135.12 29.94 34.08 32.59 35.71 33.55 32.01 135.16 29.87 33.46 32.90 35.61 33.41 31.93 135.20 29.05 32.76 31.97 35.48 33.37 32.01 135.24 29.25 34.01 32.55 35.70 34.98 31.86 135.28 29.09 33.48 32.79 34.68 34.80 32.15 135.32 28.32 34.12 31.93 35.02 35.03 32.01 135.36 27.72 32.61 31.26 34.93 33.34 31.85 135.40 26.92 32.86 31.29 34.12 34.17 31.28 135.44 26.87 32.61 31.93 34.24 33.45 31.21 135.48 27.01 32.75 31.32 34.81 32.68 31.33 135.52 27.68 32.74 30.55 35.01 33.47 30.49 135.56 27.75 31.90 31.16 34.86 33.31 29.91 135.60 28.47 32.75 31.33 34.80 33.50 29.13 135.64 27.67 32.72 30.55 34.21 34.15 29.04 135.68 27.82 32.60 30.40 34.69 33.39 29.92 135.72 28.47 32.84 30.63 34.94 33.54 29.79 135.76 28.42 32.74 31.11 34.21 33.35 29.31 135.80 28.48 32.72 32.12 34.73 33.50 29.08 135.84 29.16 32.10 31.30 34.17 32.79 29.00 135.88 30.40 32.03 31.20 34.09 32.63 29.22 135.92 29.89 31.90 30.67 34.25 34.25 29.00 135.96 26.98 32.09 29.83 34.26 33.30 29.23 136.00 27.59 31.92 29.77 34.06 32.86 29.02 136.04 27.69 31.93 29.97 34.23 31.24 28.38 136.08 26.96 32.12 30.42 34.05 31.05 28.51 136.12 27.06 31.21 30.63 34.29 31.28 27.63 136.16 27.04 31.19 31.30 34.20 31.17 28.50 136.20 27.58 31.32 29.77 33.30 31.35 28.35 136.24 28.54 31.19 29.97 33.50 31.21 28.52 136.28 27.68 31.31 29.79 33.36 30.39 28.38 136.32 26.93 30.53 29.71 33.59 31.36 27.61 136.36 27.07 29.76 30.64 34.19 33.29 27.73 136.40 26.79 31.39 30.46 34.14 32.10 27.56 136.44 26.14 31.30 30.64 34.20 31.97 27.79 136.48 26.31 31.19 30.64 34.07 32.03 27.65 136.52 25.52 30.73 30.51 34.26 31.99 27.76 136.56 26.33 30.62 30.70 33.46 31.94 27.67 136.60 27.03 31.18 29.80 33.37 31.40 27.62

136.64 27.55 31.40 29.60 33.55 31.20 27.73 136.68 26.37 30.57 29.96 33.25 32.08 27.63 136.72 26.34 30.45 29.81 33.47 31.29 27.85 136.76 26.15 31.33 29.14 33.47 31.23 26.99 136.80 26.44 30.54 29.19 33.28 31.31 27.03 136.84 25.52 30.47 29.76 33.53 31.91 27.02 136.88 26.15 31.37 29.98 34.11 31.40 26.95 136.92 26.38 31.29 29.86 33.36 31.27 27.73 136.96 26.14 31.27 29.76 34.15 31.14 27.61 137.00 26.13 30.58 29.92 34.10 32.08 28.48 137.04 26.36 30.45 29.72 34.29 31.88 27.71 137.08 26.11 30.64 29.85 34.16 32.78 28.36 137.12 26.31 30.62 30.54 34.07 33.40 27.78 137.16 26.25 30.46 30.49 33.55 32.60 28.27 137.20 26.10 31.38 29.95 34.06 32.82 27.78 137.24 26.38 31.24 29.16 33.59 32.57 27.68 137.28 25.61 31.11 29.05 33.53 32.15 27.55 137.32 24.65 30.62 29.20 33.35 31.94 28.46 137.36 25.71 31.12 29.03 34.25 31.09 28.34 137.40 25.52 31.13 29.75 33.39 31.31 28.53 137.44 26.88 31.31 29.99 33.58 31.14 28.28 137.48 25.65 30.43 29.75 34.14 32.11 27.77 137.52 25.52 29.72 29.90 33.89 31.20 27.74 137.56 25.44 31.35 29.20 34.12 31.91 27.63 137.60 25.53 31.20 29.72 34.08 32.79 27.77 137.64 25.48 31.37 29.95 34.23 31.88 26.86 137.68 25.63 30.60 28.99 34.10 32.11 27.14 137.72 25.65 30.40 29.04 33.99 31.20 27.61 137.76 26.18 30.70 29.15 34.26 30.42 27.58 137.80 26.47 30.64 29.01 34.10 31.22 27.64 137.84 25.60 29.71 29.24 33.55 31.93 27.71 137.88 25.47 29.89 28.47 33.46 32.17 27.81 137.92 25.71 29.12 28.27 33.36 32.65 27.58 137.96 24.80 29.68 28.48 33.47 33.48 27.76 138.00 24.67 30.57 28.40 34.07 32.74 28.47 138.04 25.66 29.76 29.02 34.31 32.64 27.54 138.08 25.43 29.19 29.13 33.45 32.82 27.03 138.12 25.45 29.98 28.28 33.26 31.90 26.89 138.16 26.25 29.00 28.56 33.54 31.47 27.09 138.20 26.17 29.94 28.47 33.39 32.00 26.83 138.24 25.70 29.13 28.28 33.53 31.81 26.27 138.28 25.55 28.95 27.74 33.49 32.05 26.35 138.32 25.53 29.30 27.62 34.00 31.85 26.92 138.36 24.29 29.18 28.43 33.48 31.35 26.36 138.40 22.72 28.31 27.68 33.30 32.74 26.15 138.44 23.31 28.47 27.62 33.49 33.34 26.38 138.48 22.82 27.74 27.79 32.74 31.29 26.33 138.52 23.36 26.91 27.68 31.92 32.63 25.35 138.56 23.34 27.14 27.57 32.12 31.36 25.63 138.60 23.52 26.23 27.03 31.24 30.58 25.44 138.64 22.67 26.15 26.23 31.24 30.60 24.96 138.68 22.83 26.40 25.61 30.60 29.87 24.17

138.72 22.78 26.12 26.25 30.47 29.04 24.01 138.76 22.70 26.30 25.49 30.71 28.42 24.17 138.80 22.89 26.36 26.33 30.56 28.32 24.05 138.84 22.74 26.20 25.48 30.40 28.55 24.27 138.88 22.68 25.64 25.41 30.61 28.50 24.18 138.92 22.90 25.66 25.65 30.37 28.27 23.49 138.96 22.60 25.49 24.66 30.60 28.51 23.52 139.00 22.60 25.65 24.76 29.76 28.30 24.04 139.04 22.79 25.54 24.88 29.72 27.74 24.23 139.08 22.73 26.27 24.75 29.83 28.35 23.42 139.12 22.81 25.65 24.97 28.93 28.37 23.59 139.16 22.11 25.61 24.28 29.87 27.75 23.48 139.20 22.03 25.48 24.05 29.12 26.89 23.23 139.24 22.17 25.63 25.59 29.01 27.08 23.55 139.28 22.81 25.53 24.81 29.12 26.98 23.99 139.32 22.04 25.37 24.79 29.80 27.62 23.56 139.36 21.48 27.12 24.91 29.90 27.06 24.03 139.40 22.04 25.50 25.48 29.82 26.96 23.48 139.44 21.92 25.53 25.61 29.88 27.04 23.52 139.48 22.11 25.64 25.57 30.67 26.94 23.28 139.52 21.32 26.17 26.21 30.49 29.08 23.49 139.56 21.89 25.62 25.69 30.68 27.04 22.69 139.60 22.74 25.62 25.58 30.49 26.86 22.84 139.64 22.67 25.44 26.10 30.52 27.06 23.47 139.68 22.84 25.69 25.52 30.53 26.23 22.69 139.72 22.81 25.62 25.57 30.49 26.93 23.56 139.76 21.95 25.48 26.35 30.72 26.33 23.35 139.80 22.19 25.65 26.24 29.86 26.88 23.51 139.84 22.06 25.55 26.22 29.01 27.11 23.33 139.88 22.00 25.43 26.40 29.24 27.56 23.55 139.92 22.81 25.66 25.60 29.03 27.72 23.47 139.96 21.97 25.57 25.40 28.51 26.97 23.38 140.00 21.95 25.40 26.30 28.31 26.93 23.51 140.04 22.04 25.65 26.97 29.06 27.08 23.38 140.08 22.00 25.53 27.03 29.22 26.20 23.57 140.12 22.11 25.60 25.66 28.34 25.63 23.42 140.16 22.06 25.62 25.53 28.53 26.36 24.01 140.20 21.97 25.48 26.35 28.36 26.21 23.51 140.24 22.14 25.73 25.40 29.02 27.05 24.03 140.28 22.13 26.32 26.14 29.15 26.16 24.32 140.32 22.73 25.49 25.58 29.01 26.45 24.00 140.36 22.83 25.68 26.91 29.18 26.95 23.37 140.40 23.35 25.55 27.01 29.81 26.11 23.53 140.44 23.30 24.68 26.25 29.70 26.36 23.42 140.48 23.51 25.68 26.26 29.94 26.18 23.50 140.52 24.01 25.57 25.64 29.75 25.63 23.38 140.56 23.34 25.45 25.58 29.20 25.62 22.86 140.60 23.56 25.64 25.45 28.36 25.41 22.70 140.64 22.67 24.79 26.27 28.37 26.36 23.28 140.68 22.83 24.82 26.13 28.51 26.15 22.78 140.72 22.11 25.53 25.65 28.32 26.43 22.61 140.76 22.65 25.44 25.62 28.54 25.58 22.89

140.80 22.89 25.65 25.39 28.41 25.38 22.75 140.84 22.69 24.88 24.96 28.33 25.63 21.96 140.88 23.37 25.44 24.18 27.74 24.74 22.16 140.92 22.84 25.69 24.78 28.33 24.99 22.02 140.96 23.34 25.64 24.92 27.77 24.76 22.14 141.00 22.67 25.48 24.80 26.91 24.17 21.99 141.04 22.75 25.71 24.68 26.14 24.88 22.19 141.08 22.63 25.59 24.10 26.34 24.71 22.03 141.12 22.84 25.52 24.76 25.40 24.98 21.23 141.16 22.79 25.70 24.90 26.36 24.82 22.11 141.20 22.70 24.75 24.81 25.60 24.95 21.91 141.24 22.82 25.43 24.86 25.42 24.21 22.16 141.28 22.69 24.85 24.24 25.69 24.02 22.08 141.32 22.53 24.70 24.69 25.43 24.23 21.91 141.36 22.79 24.80 24.10 25.68 24.05 21.33 141.40 22.65 24.85 24.93 25.47 24.95 22.00 141.44 22.82 24.76 24.02 25.39 24.22 22.14 141.48 22.85 24.91 24.24 25.61 23.98 22.62 141.52 22.60 24.89 24.10 25.41 24.15 22.78 141.56 22.19 24.74 24.10 24.93 24.07 22.81 141.60 22.08 24.90 23.50 24.88 24.21 22.59 141.64 22.68 24.98 23.99 25.42 24.06 22.86 141.68 22.83 24.74 24.11 25.54 23.99 22.01 141.72 21.91 24.97 23.49 24.70 23.41 22.16 141.76 22.65 25.61 23.30 25.00 24.13 21.34 141.80 22.14 25.48 23.55 24.77 24.27 21.96 141.84 21.92 26.38 23.53 24.71 24.10 21.34 141.88 22.04 25.63 23.38 24.82 24.13 21.94 141.92 22.05 24.76 23.55 24.68 24.13 21.49 141.96 21.96 24.91 23.38 24.92 24.14 21.28 142.00 21.48 24.80 23.36 24.15 24.27 21.40 142.04 21.38 25.58 23.50 24.67 23.34 22.04 142.08 21.96 25.58 23.29 24.23 24.24 21.89 142.12 22.13 25.50 23.57 24.68 24.18 22.16 142.16 22.10 25.64 24.15 24.32 24.11 22.69 142.20 22.07 26.27 23.33 24.84 24.09 22.16 142.24 22.11 26.15 24.27 24.07 24.09 21.36 142.28 21.31 26.36 24.73 24.16 23.57 21.23 142.32 22.07 26.28 24.15 24.02 24.23 21.26 142.36 22.18 26.96 24.16 24.27 24.03 21.15 142.40 21.22 27.08 24.81 24.01 24.20 21.44 142.44 21.45 26.99 24.99 24.06 24.11 20.73 142.48 21.34 26.87 24.92 24.31 24.25 21.39 142.52 21.22 27.12 24.82 24.02 23.52 22.10 142.56 21.48 27.67 24.97 24.25 23.28 21.29 142.60 21.37 26.84 24.89 24.12 24.21 22.12 142.64 21.25 27.79 24.70 23.92 24.10 21.92 142.68 21.42 27.63 24.87 24.14 24.28 22.87 142.72 21.32 27.57 25.48 24.05 23.41 21.99 142.76 20.55 27.74 25.69 24.24 23.99 21.96 142.80 20.69 27.67 25.63 24.25 24.14 22.16 142.84 20.52 27.62 24.76 24.74 24.06 22.76

142.88 21.45 27.81 24.97 24.31 24.25 22.13 142.92 21.42 27.62 24.78 24.77 24.06 22.69 142.96 20.51 27.01 24.77 24.20 24.06 21.47 143.00 20.74 27.04 24.95 24.26 23.50 22.82 143.04 20.67 26.91 24.75 24.06 23.35 21.95 143.08 20.53 27.15 24.89 24.21 23.49 21.36 143.12 20.74 26.34 24.93 24.10 23.42 21.25 143.16 20.66 26.88 24.70 24.16 24.16 20.76 143.20 20.50 26.36 24.92 23.55 23.44 20.61 143.24 20.70 25.52 24.10 23.39 23.38 22.04 143.28 19.83 25.49 24.00 23.51 23.50 21.50 143.32 20.01 25.01 24.15 22.74 23.28 21.32 143.36 20.63 24.86 24.03 22.79 23.57 21.38 143.40 19.87 24.74 23.57 22.79 23.41 21.92 143.44 20.07 24.25 24.22 22.67 22.57 22.87 143.48 20.72 24.85 24.03 22.83 22.78 22.05 143.52 20.59 24.75 24.25 22.64 23.33 21.91 143.56 20.05 24.20 24.02 22.85 23.53 22.08 143.60 19.93 24.13 24.00 22.84 22.67 21.90 143.64 19.83 24.09 24.13 22.65 23.31 22.15 143.68 19.29 24.17 24.71 22.84 22.85 21.34 143.72 19.24 24.09 24.21 22.71 22.03 21.35 143.76 19.17 24.21 24.91 22.85 22.15 21.34 143.80 19.98 24.26 24.76 22.78 22.78 21.32 143.84 19.95 23.31 24.96 22.71 22.79 22.15 143.88 19.96 24.25 24.84 22.87 22.81 21.97 143.92 19.20 23.44 24.80 22.01 22.62 22.84 143.96 19.12 22.55 24.91 22.83 23.48 22.12 144.00 20.05 24.22 24.76 22.79 22.69 21.26 144.04 19.33 23.51 24.96 22.64 22.83 21.35 144.08 19.20 23.38 24.90 22.08 24.14 20.57 144.12 19.37 23.55 24.76 21.95 24.07 20.84 144.16 19.25 23.44 24.95 22.05 24.22 21.32 144.20 19.15 24.01 24.71 22.04 24.01 20.55 144.24 19.36 23.50 24.71 21.92 24.28 20.62 144.28 19.19 23.45 24.91 22.20 24.14 20.64 144.32 19.07 23.34 24.71 21.94 23.93 20.73 144.36 19.27 23.56 24.13 22.08 24.15 21.27 144.40 19.82 22.65 24.21 22.11 24.01 21.47 144.44 18.60 22.05 24.09 21.94 24.96 21.36 144.48 18.50 22.87 24.24 22.11 24.87 21.15 144.52 18.47 21.24 24.03 21.21 25.42 21.28 144.56 18.65 21.40 23.34 20.62 25.68 20.49 144.60 18.59 21.39 23.40 19.99 25.50 20.06 144.64 17.78 21.21 22.59 20.57 25.63 19.91 144.68 18.65 21.52 22.83 20.72 25.55 20.02 144.72 18.57 21.33 22.81 19.81 25.64 20.72 144.76 18.43 21.31 22.00 20.63 26.34 21.29 144.80 18.57 20.85 22.15 20.68 26.13 20.64 144.84 18.47 21.36 21.26 20.58 24.92 20.61 144.88 18.39 20.56 21.34 20.73 24.82 20.73 144.92 18.68 20.79 21.39 20.51 24.93 21.28

144.96 18.47 20.62 20.49 20.74 24.80 19.90 145.00 18.53 20.49 21.49 20.65 24.74 19.34 145.04 18.62 21.42 21.33 20.57 25.53 19.20 145.08 18.41 20.49 21.16 20.73 24.74 18.63 145.12 18.00 20.57 21.44 20.56 25.03 18.50 145.16 18.61 20.77 21.28 20.81 24.17 18.69 145.20 18.49 20.61 22.17 21.40 23.96 19.25 145.24 18.64 20.01 21.34 21.23 23.51 19.13 145.28 17.83 20.65 21.33 20.70 23.29 18.58 145.32 17.07 20.53 21.47 20.54 23.55 18.38 145.36 17.23 20.78 22.04 20.80 23.37 17.98 145.40 17.10 19.92 22.64 20.75 22.84 17.69 145.44 17.69 20.56 22.73 20.51 23.37 17.19 145.48 17.87 20.77 21.23 20.02 22.67 17.30 145.52 17.75 20.55 20.76 19.83 21.40 17.05 145.56 17.26 19.78 21.40 20.05 21.28 17.25 145.60 17.96 20.04 21.28 19.27 20.72 17.07 145.64 17.70 20.56 21.38 19.13 20.64 17.27 145.68 17.97 19.93 20.55 19.25 20.55 17.17 145.72 17.29 19.27 21.39 19.20 20.02 17.76 145.76 17.06 19.18 21.29 19.36 19.81 17.12 145.80 17.94 18.63 20.56 19.31 20.01 16.31 145.84 17.77 19.24 20.78 19.08 19.19 17.29 145.88 16.98 19.86 20.02 19.25 19.18 17.72 145.92 17.22 19.35 19.13 19.15 19.24 16.47 145.96 16.98 19.97 19.31 18.66 19.11 17.22 146.00 16.47 20.46 19.93 18.53 19.41 17.78 146.04 16.63 21.46 19.97 19.20 19.22 18.61 146.08 16.33 21.36 20.05 18.64 19.25 16.37 146.12 16.55 20.58 19.85 18.45 18.58 17.33 146.16 16.48 20.08 20.02 18.66 18.46 16.43 146.20 16.35 19.26 20.01 18.50 18.63 16.95