'o,,

UNITED STATES

NUCLEAR REGULATORY COMMISSION n

m REGION 11

e 101 MARIETTA ST., N.W SUITE 3100 k

ATLANTA, GEORGIA 30303

Report No. 50-395/82-32 Licensee:

South Carolina Electric and Gas Company P. O. Box 764 Columbia, SC 29218 Facility Name:

V. C. Summer Nuclear Plant Docket No. 50-395 License No. CPPR-94 Inspection at Summer site near Colu bla South Carolina I

y'

'

Inspector:

/1-J. J. Lenahan g'

Date Signed ([X d/[PE Approved by.~T. E. Conlon, Section Chief Date Signed

-

Engineering Inspection Branch Division of Engineering and Technical Programs SUMMARY Inspection on May 6-7, 1982 Areas Inspected This routine, announced inspection involved 8 inspector-hours on site in the areas of reactor building tendon surveillance and the nuclear service water pond.

Results Of the areas inspected, no violations or deviations were identified.

8206220462 820525 PDR ADOCK 05000395 G

PDR

__

. -

_

_

_

_

.

.

-- _

_--. _._

_.

..

.

.

.

J

,

REPORT DETAILS

.

1.

Persons Contacted

,

Licensee Employees

,

'

  • 0. Bradham, Station Manager
  • W. A. Williams, Jr., General Manager, Nuclear Operations
  • S. S. Howze, Nuclear Licensing Engineer
  • J. K. Todd, Nuclear Engineer
  • R. J. Bouknight, Quality Assurance Specialist NRC Resident Inspector
  • J. L. Skolds
  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on May 7,1982, with those persons indicated in paragraph 1 above.

3.

Licensee Action on Previous Inspection Findings Not inspected.

4.

Unresolved Items i

"

Unresolved items were not identified during this inspection.

j 5.

Independent Inspection Effort i

l The inspector examined the nuclear service water pond.

The inspector observed that a deficiency that had been noted by licensee engineers in the j

1981 annual inspection of service water pond concerning growth of vegetation on the embankment slopes had been corrected. Discussions with the licensee

,

personnel disclosed that this was accomplished by spraying the embankment slopes with a herbicide and that the spraying will be repeated whenever j

necessary to prevent vegetation from growing on the embankment slopes.

!

No deviations or violations were identified.

!

6.

Containment Building Tendon Surveillance

,

The inspector examined procedures and quality records relating to the containment building tendon surveillance. Acceptance criteria examined by the inspector appear in the proposed Revision 3 to Reg Guide 1.35, FSAR Section 3.8.1.7.2, and the proposed Summer Tech Spec 4.6.1.6.1.

Details of the inspection were as follows:

i

t

,n. - -,, -

--n-w-

,,,.--,--r,-,,

, -,,,. - - -

v

- -, - -

+~---w

,,----,-r--


+-------e-

-,---w--

- - - ~ -, -

~v---

~---- " ~ '

'--'"-*r*

,.

'.

a.

Review of-Tendon Surveillance Procedures The inspector examined the following procedures which control the tendon surveillance activities:

(1)' Specification SP-228, " Surveillance of Reactor Building Post Tensioning System" (2)

INRYC0 Surveillance Program - Quality Control Manual (3)- Engineering Change Notices (ECN) numbers 1943,'2163, and 2198 6.

Review of Quality Records Relating to Tendon Surveillance Activities The inspector examined the following ~ records relating to tendon surveil-lance.

a.

SCE&G QA Surveillance Report No. 48242, Subject: INRYC0 Surveillance Test Program b.

Suiveillance inspection records for tendons listed in table below.

Th ese records included the results of end anchorage inspection, lift-of f data, and sheathing filler inspection.

TABLE Vertical Tendons Hoop Tendons Dome Tendons V-23 3 AC D-103 V-46 8 BA D-104 V-67 13 CB D-105 V-68 27 CB D-128 V-69 28 CB D-129 V-92 35 AC D-130 V-115 36 AC D-218 37 AC D-219 38 AC D-220 39 AC D-327 40 AC 37 BA 38 BA 39 BA c.

Stressing ram calibration records for ram numbers 8755, 8833, 9361, and 9362 d.

Nonconformance report numbers F1550-001, F1550-004 through 10, and F1550-012

.

_

.

_

.

.,..b

e.

Retensioning data for tendon numbers 8BA, 36AC, 37AC, and 38AC. :This data includes' elongation measurements, thickness of shims, and new lift-off force.

Review of the lif t-off data disclosed that the lift-off force in several tendons was slightly lower than the predicted lower limit values stated in

'

Table 4.6-la of the draft of Technical Specification 4.6.1.6.1.

However, the normalized lift-off forces for these tendons were well above the required minimum values stated in the draft _ technical specifications and were also above those required by design to maintain structural integrity of the containment.

The licensee will address the problem of the actual lif t-off force in the tendons being slightly below the predicted lift-off values in the report on the tendon surveillance inspection. This report will be submitted to NRC.

No violations or deviations were identified.

.

f

I l

!

!

!

-

_

-.

. _ -

.

-

.

_

.-

-

.

. _

. - -