IE Insp Repts 50-250/79-17 & 50-251/79-17 on 790523-25.No Noncompliance Noted.Major Areas Inspected:Concrete Expansion Anchor Testing & Repair Program
ML17338B025
Person / Time
Site: Turkey Point  
Issue date: 06/07/1979
From: Herdt A, Madenos L, Vallish E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML17338B024 List:
References
50-250-79-17, NUDOCS 7908210279
Download: ML17338B025 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100 ATLANTA,GEORGIA 30303 Report Nos. 50-250/79-17 and 50-251/79-17 Licensee:

Florida Power and Light Company 9250 West Flagler Street Miami, Florida 33101 Facility Name:

Turkey Point Nuclear Plant, units 3 6 4 Docket, Nos.

50-250 and 50-251 license Nos.

DPR-31 and DPR-41 Inspection at Turkey Point Nuclear Plant near Homestead, Florida Inspectors:

L.

odenos 2~p=

Date igned Date igned Approved by:

A.

SUMMARY R. Herdt, Section Chief, RCES Branch I

D te Signed Inspection on May 23-25, 1979 Areas Inspected This special, unannounced inspection involved twenty eight inspector hours onsite by two NRC inspectors, of the concrete expansion anchor testing and repair program.

Results No apparent items of noncompliance or deviations were identified.

,e g008$ 109'7P

-2-b.

Bechtel Procedure No. 5177-098-P-1 R2, "Repair Procedure for Concrete Expansion Anchors and Base Plates for Safety Related Pipe Supports".

The following hangers in Unit 4 were inspected and the repair work in progress was observed:

DR"137-035 DR-137"033 NCR-137"013 NCR-137"015 The following Unit 4 hangers, the repairs on which vere completed, were inspected:

DR-137-034 NCR"137"004 NCR-137-013 NCR-137-015 The licensee stated that during the testing and inspection of these anchors in Unit 4 the failures were categorized as functional failures or nonfunc-tional failures, where the functional failure would have resulted in the loss of function of that anchor.

The licensee stated that all functional failures identified would be repaired prior to start"up and that those identified as nonfunctional failureswould be repaired in the future.

/

No items of noncompliance or deviations were identifie DETAILS 1.

Persons Contacted Iicensee Employees

+H. E. Yaeger, Plant Manager

  • S. Brain, Engineering Project Manager
  • D. L. Hartsfield, Superintendent General Construction

+F.

W. Rothermel, Construction Superintendent

  • G. D. Whittier, Sr. Licensing Engineer

+E. F. Baker, QA Engineer

Other licensee employees contacted included construction craftsmen, QC inspectors and Supervisors.

Other Organizations

+A. K. Beckman, Bechtel Resident Engineer

+J.

D. Gregg, Bechtel Lead Resident Engineer

+Attended exit interview 2.

Exit Interview I

The inspection scope and findings were summarized on May 25, 1979, with those persons indicated in Paragraph 1 above.

3.

Licensee Action on Previous Inspection Findings Not inspected.

4.

Unresolved Items Unresolved items were not identified during this inspection.

5.

Concrete Expansions Anchors - Units 3 & 4 In response to IE Bulletin No. 79-02 Florida Power and Light Company (FPL)

initiated a test program to identify and correct deficiencies of the safety-related anchor bolt installations.

The test program covered all anchor bolts used in all the systems that the licensee identified as necessary for cold shutdown of the plant during a Safe Shutdown Earthquake (SSE).

The following procedura for Units 3 S 4 used by the licensee for this work were reviewed:

a.

Quality Instruction (QI) 10.24 RO Inspection and Testing of Concrete Expansion Anchors for Installed Pipe Supports.