05000301/LER-1998-002, Forwards LER 98-002-00 Re Serious Degradation of Reactor Coolant Pump Component Cooling Water Return Line Check Valve Which May Prevent Closure

From kanterella
(Redirected from 05000301/LER-1998-002)
Jump to navigation Jump to search
Forwards LER 98-002-00 Re Serious Degradation of Reactor Coolant Pump Component Cooling Water Return Line Check Valve Which May Prevent Closure
ML20216G402
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 04/13/1998
From: Dante Johnson
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20216G407 List:
References
NPL-98-0253, NPL-98-253, NUDOCS 9804200336
Download: ML20216G402 (1)


LER-2098-002, Forwards LER 98-002-00 Re Serious Degradation of Reactor Coolant Pump Component Cooling Water Return Line Check Valve Which May Prevent Closure
Event date:
Report date:
3012098002R00 - NRC Website

text

r 7 l

1 i Wisconsin

Electnc POWER COMPANY Point Beoch Nuclear Plant (920) 755-2321 6610 Nuclear Rd., Two Rivers. WI 54241 NPL 98-0253 April 13,1998 Document Control Desk U.S. NUCLEAR REGULATORY COMMISSION Mail Station P1-137 Washington, D C 20555 Ladies / Gentlemen

DOCKET 50-301 LICENSEE EVENT REPORT 1998-002-00 REACTOR COOLANT PUMP COMPONENT COOLING WATER RETURN LINE CHECK VALVE SERIOUSLY DEGRADED POINT BEACH NUCLEAR PLANT. UNIT 2 Enclosed is Licensee Event Report 1998-002-00 for Point Beach Nuclear Plant, Unit 2. This report is provided in accordance with 10 CFR 50.73(aX2Xii), "Any event or condition that resulted in the condition of the nuclear power plant, including its principal safety barriers, being -

seriously degraded." This report describes the discovery of a reactor coolant pump component cooling water return line check valve in a condition that would prevent its closure. This condition could result in loss of component cooling fluid into containment given the unlikely event of the break of a reactor coolant pump component cooling line and the simultaneous failure of a remote operated isolation valve.

If you require additional information, please contact us.

Sinarely, o son j.

Manager, -

Regulatory Services & Licensing Enclosure \ 1 cc: NRC Resident Inspector r

- NRC Regional Administrator NRC Project Manager

's [_

INPO Support Services 9804200336 980413 PDR ADOCK 05000301 S - PDR

.--vd30 A subsMhg ofHismnskfirg Owprrathn  ;

__b