IR 05000010/1987003

From kanterella
Revision as of 10:52, 6 December 2021 by StriderTol (talk | contribs) (StriderTol Bot change)
Jump to navigation Jump to search
Partially Withheld Physical Protection Insp Repts 50-010/87-03,50-237/87-12 & 50-249/87-12 on 870326-31 (Ref 10CFR73.21).Violation Noted:Protected Area Barrier Significantly Degraded
ML20206F796
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 04/08/1987
From: Creed J, Madeda T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20206F758 List:
References
50-010-87-03, 50-10-87-3, 50-237-87-12, 50-249-87-12, NUDOCS 8704140366
Download: ML20206F796 (1)


Text

.. .. -_ -

'l U.S. NUCLEAR REGULATORY COMMISSION

REGION III

.

Reports No. 50-10/87003(DRSS); 50-237/87012(DRSS); 50-249/87012(DRSS)

lf Docket Nos. 50-10; 50-237; 50-249 Licenses No. DPR-2; DPR-19; DPR-25

! Licensee: Commonwealth Edison Company Post Office Box 767

Chicago, IL 60690 Facility Name: Dresden Nuclear Power Station, Units 1, 2, and 3 Inspection At: Dresden Site, Morris, Illinois Date of Previous Inspection: January 6-9, 1987 Inspection Conducted: Onsite, March 26, 1987; Office Review, March 30-31, 1987 Type of Irspection: Announced, Special Physical Protection Inspector: 4 1- 1./ev N / ' !27 u

'

4 T.' J. Madeda Date Phys Security Inspector Approved By: / au-t.-

'

[g 87 J_.X/ Creed, Chief Date '

i Safeguards Section

!

Inspection Summary

Inspection on March 26-31, 1987 (Reports No. 50-10/87003(DRSS);

No. 50-237/87012(DRSS); No. 50-249/87012(DRSS)

Areas Inspected: Included a review of the circumstances surrounding the

, degradation of a protected area barrier which was identified in accordance with security event reporting requirements 10 CFR 73.71(c).

Results: The licensee was found to be in compliance with NRC requirements, j except as noted below:

Physical Barrier - Protected Area: A protected area barrier was significantly degrade Additionally, an unresolved item was noted regarding a potentially degraded

} vital area barrier.

!

t

(Details
Unclassified Safeguards Information)

I Enclosure Contafns

' 6 370409 O SAFEGUARDS lilFORMAT10N 87041 OCg OSOOO p g . Upon Separation This -

'

PDR PaDo is DecontrolIcd O

. - - - - - . - , .

- .. .__ ... .. . , . - . - , . - . - . _ . - - .

- . . - . - .