Forwards Nonproprietary WCAP-13218 & Proprietary WCAP-13211, NRC Bulletin 88-008 Evaluation of Auxiliary Piping for Comanche Peak,Unit 2. Proprietary Rept Withheld (Ref 10CFR2.790)
ML20092L521
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 02/24/1992
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20034D245 List:
References
IEB-88-008, IEB-88-8, TXX-92078, NUDOCS 9202260315
Download: ML20092L521 (2)


Text

o. ,s, r

" "'"J"

':lllll" = Log # TXX-92078
2 File # 903.6 g ~

Ref. # 10CfR2.790 1UELECTRIC Febru6ry 24. 1992 William J. CaMll. Jr.

Germp s*we Preskimt U. S. Nuclear Regulatory Commission Attn: Document Control Dest Washington. D. C. 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) - UNIT 2 DOCKET NO. 50 446 ANALYSES Of THERHAL STRESSES IN THE RCS BRAtlCH LINES Gentlemen:

TV Electric indicated that the issue of potential thermal stratification effects for the CPSES Unit 2 RCS Branch lines would be submitted before Unit 2 initial criticality. TV Electric has completed analyses of the potential effects of thermal stratification on the CPSES Unit 2 RCS Branch lines. The analyses show that thermal stratification will not affect the integrity of these branch lines and that the requirements of flRC Bulletin 88-08 are satisfied.

The first enclosure consists of five (5) copies of WCAP-13211. titled 'NRC Bulletin 88 08 Evaluation of Auxiliary Piping for Comanche Peak Unit 2" (Proprietary).

The second enclosure consists of five (5) copies of WCAP-13218. titled 'NRC Bulletin 88 08 Evaluation of Auxiliary Piping for Comanche Peat Unit 2" (flon-Proprietary).

The t 'rd enclosure consists of a Westinghouse Application for Withholding Proprieary Information with Accompanying Affidavit CAW-92-269. Proprietary Information Notice and Copyright Hotice.

This submittal contains information proprietary to Westinghouse Electric Corporction it is supported by an affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of 10CFR2.790.

tb/C bY? / lf '

270003 Q0 g

yg q, a 6> .

9202260325 DR 920224 m.oun se Ls.si Den.sanaimot p ADOCK 05000446 PDR