Rev 4 to Pump & Valve Inservice Testing Program
ML20073C550
Person / Time
Site: Mcguire, McGuire  Duke Energy icon.png
Issue date: 03/31/1983
From:
DUKE POWER CO.
To:
Shared Package
ML20073C549 List:
References
PROC-830331, NUDOCS 8304130221
Download: ML20073C550 (406)


Text

_ _ _ _ _ _ _ _ - - - --

i / x i \

I l

I f Duke Power Company l l

McGuire Nuclear Station i

3 UnMs 1 and 2

! Pump and Valve Inservice Testing Program J

l

\

O

.I 4pogty

~~

s i

l l

l 1

i i

O l

l DUKE POWER COMPAhT McGUIRE NUCLEAR STATION PUMP AND VALVE INSERVICE TESTING

.O UNIT 1 REVISION #4 i

i O ,

l

1 J i i

J t I DUKE POWER COMPANY 1 MCGUIRE NUCLEAR STATION PUMP AND VALVE INSERVICE TESTING PROGRAM Table of Contents Section I. Pump Inservice Testing Program j Introduction and Descrip*. ion ................................. I.1 j 4I II. Valve Inservice Testing Program I Introduction ................................................. II.1 Table of Abbreviations ....................................... II.2 Definition. of Testing Requirements and Alternatives ......... -II.3 General Relief ............................................... II.4 1

l Syttems:

Annulus Ventilation (VE) ..................................... II.5 4 Aux ila ry Fe edwa te r (CA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II.6

Boron Recycle (NB) ........................................... II.7
Breathing Air (VB) ........................................... II.8

, Chemical and Volume Control (NV) ............................. II.9

Component Cooling (KC) ....................................... II.10
Containment Air Release and Addition (VQ) .................... II.11 Containment Air. Return Exchange and Hydrogen Skimmer (VX) .... II.12 Containment Purge Ventilation (VP) ........................... II.13 Containment Spray (NS) ....................................... II.14 Containment Ventilation Cooling Water (RV) ................... II.15

^

Control Area Chilled Water (YC) .............................. II.16 Diesel Generator Engine Fuel Oil (FD) ........................ II.17

Diesel Generator Room Sump Pump (WN) ......................... II.18 Diesel Generator Starting Air (VG) ........................... II.19
Equipment D-contamination (WE) ............................... II.20 Feedwater (CF) ............................................... II.21 j Fire Protection (RF) ......................................... II.22
Ice Condensor Refrigeration (NF) ............................. II.23
Instrument Air (VI) .......................................... II.24

! Liquid Waste Recycle (WL) .................................... II.25

! 41 Main Steam (SM)............................................... II.26 i Main Steam Supply to Auxiliary i Equipment / Turbine Exhaust (SA) ............................. II.27 l Main Steam Vent to Atmosphere (SV) ........................... II.28 i Makeup Demineralized Water (YM) .............................. II.29

Nuclear Sampling (NM) ........................................ II.30
Nuclear Service Water (RN) ................................... II.31 i

Reactor Coolant (NC) ......................................... II.32 Refueling Water (FW) ........................... ............. II.33 Residual Heat Removal (ND) ................................... II.34 Safety Injection (NI) ........................................ II.35 Station Air (VS) ............................................. II.36 Steam Generator Blowdown Recycle (BB) ........................ II.37 s

McGUIRE -~ UNIT 1 Revision 4

t l DUKE POWER COMPANY j MCGUIRE NUCI. EAR STATION PUMP INSERVICE TESTING PROGRAM I

ASME SECTION XI, SUBSECTION IWP i

The inservice testing of ASME Code Class 1, 2, and 3 pumps provided with an emergency power source will be tested as required by Section XI, Subsection

, IWP, of the ASME Boiler and Pressure Vessel Code 1980 Edition, except where

! specific written relief has been granted by the Commission. A description of the proposed inservice testing program, as well as specific requests for

relief f rom code requirements determined to be impractical, is described by

! the following.

!~

j 4 I. The following are specific requests for relief from certain code i requirements.

1 A) IWP-4120 requires the full scale range of each instrument to be three times the reference value or less. This was changed from four times the reference value in the edition of Section XI that was in effect prior to unit licensing. 10CFR, Section 50.55a(g)(4) states that design provisions are excluded from the requirement to

upgrade to subsequent editions of Section XI. Since any cases where j the three-times reference value criterion is not met would require design changes in instrumentation, we will continue to apply the four-times reference value criterion, as interpreted in B) below,

} for instrument accuracy evaluation.

! B) In several cases, instrumentation does not meet the four times 1

reference value criterion. These cases predominantly involve i suction pressure gauges where a larger range is required to

accommodate varying conditions at the suction of the pump. In all cases where the four-times reference value criterion cannot be met, an instrument error evaluation is performed to demonstrate that the

. overall accuracy of the differential pressure measurement is within the limits established by IWP. These cases are RHR discharge,

- nuclear service water suction, and control room chilled water suction gages.

j C) Table IWP-3100-1 establishes the parameters that are to be

] measured. The previous edition of Section 11 specified that in a fixed resistance system, either AP or Q was to be measured, not 4l both. Thecentrifugalchargingpumpsaretestedusingfixedresistancel flow paths, with no flow indication provided. Based on the design i change exclusion provided by 10CRF50.55a(g)(4), we will continue to apply the criterion that'it is not required to. measure flow in a fixed resistance system.

1

! D) Table IWP-4110-1 states that vibration measurement should have an 4 accuracy of i 5%. McGuire has no permanently installed vibration instrumentation. The portable instruments used to measure vibration have an uncertainty of t 11%.

McGUIRE - UNIT 1 I.1-1 Revision-4

II. The following Safety Class 1, 2, and 3 pumps (See Attachment #1 for specific safety class and available instrumentation) will be tested in accordance with the intent of Subsection IWP of the ASME code:

NUCLEAR SERVICE WATER PUMPS (IA, IB)

CONTAINMENT SPRAY PUMPS (IA, IB)

SAFETY INJECTION PUMPS (IA, IB)

MOTOR-DRIVEN AUX. FEEDWATER PUMPS (IA, IB)

TURBINE-DRIVEN AUX. FEEDWATER PUMP (NO. 1)

CENTRIFUGAL CHARGING PUMPS (IA, IB)

COMPONENT COOLING PUMPS (IA1, IA2, IB1, 1B2)

RESIDUAL HEAT REMOVAL PUMPS (IA, IB)

III. The following Safety Class 1, 2, and 3 pumps (See Attachment #1 for specific safety class and available instrumentation) will be tested in accordance with the intent of Subsection IWP, except for the request for relief for the specific requirements determined to be impractical as described below.

A) PUMP: CONTROL AREA CHILLED WATER PUMPS (CRA-P-1, CRA "-2)

SAFETY CLASS: 3 FUN CION: To provide chilled water to air handling units supplying control area air conditioning TEST REQUIREMENTS: 1. Measure pump bearing temperature during inservice testing.

2. Annually run pumps until bearing temperatures stabilize.

BASIS FOR RELIEF: There is no instrumentation installed to measure bearing temperature, and no meaningful data can be obtained from bearing housing surface temperature measurements.

ALTERNATE TESTING: The inservice testing of the Control Area Chilled Water Pumps will be in accordance with the intent of Subsection IWP except that bearing temperature will not be monitored and subsequently the pumps will not be run annually until bearing temperature 4 stabilizes.

IV. The following Safety Class 1, 2, and 3 pumps are provided with insufficient instrumentation to perform any meaningful testing in accordance with the intent of Subsection IWP and therefore the following alternate testing methods, as well as requests for relief from compliance with Subsection IWP, are described by the following. g McGUIRE - UNIT 1 I.1-2 Revision 4 1

l A) PUMP: D/G FUEL OIL TRANSFER PUMPS (IA, IB)  !

SAFETY CLASS: 3 FUNCTION: Diesel generator auxiliary support TEST REQUIREMENT: Test pumps in accordance with Subsection IWP BASIS FOR RELIEF: Pumps contain insufficient instrumentation (See Attachment #1) to perform any meaningful testing in accordance with the intent of Subsection IWP.

ALTERNATE TESTING: Monthly Diesel Generator starting and loading as required by McGuire Technical Specifications is sufficient in assessing the hydraulic condition of the subject auxiliary pumps and demonstrating the capability of the individual components to perform their design function.

The mechanical condition of the subject pumps will be determined from vibration data to be gathered monthly. Flow will be monitored by observing level rise in the day tank.

B) PUMP: D/G ROOM SUMP PUMPS (IA2, IA3, IB2, IB3)

SAFETY CLASS: 3 FUNCTION: Water removal from Diesel Generator rooms TEST REQUIREMENT: Test pumps in accordance with Subsection IWP BASIS FOR RELIEF: Pumps contain insufficient instrumentation (See Attachment #1) to perform any meaningful testing in accordance with Subsection IWP.

ALTERNATE TESTING: Due to the anticipated infrequent normal operation of these pumps, quarterly, each pump will be verified to be capable of performing their design function of removing water from the sump at a rate greater than or equal to 419 gpm.

The time which it takes to pump a known volume 4 from the sump is recorded and converted to a flow rate.

1 O

McGUIRE - UNIT 1 I.1-3 Revision 4

SAFETY RELATED CLASS 1, tND 3 PUMPS PROVIDED WITH AN m" g EMERGENCY POWER SOURCE :n,

.o .

, g C 2 $ $ $ - $ E

5  :  : E 3 & s a O E $ $ $ d u $ e 3 u
  • 5 3 E e e M

& 5 w 3 3 2 t "

4 a .

a 8 3 0 3 .a .0 M M .8 PUMPS Nuclear Service Water Pumps (IA, IB) (RN) 3 QU NR X X X X(1) X X X  ?!C-1574-1.1 Containment Spray Pumps (IA, IB) (NS) 2 QU NR X X X X(1) X(3) X(2)_ X MC-1563-1.1 4 l Restdual IIcat Removal Pumps (IA, IB) (ND) 2 QU NR X X X X(1) X(3) X(2) X MC-1561-1.0 l Safety Injection Pumps (IA, IB) (NI) 2 QU NR X X X X(1) X X X MC-1562-3.0 F/D Aux. Feedwater Pumps (IA, IB) (CA) 3 MO NR X X X X(1) X X X MC-1592-1.1 T/D Aux. Feedwater Pump (No. 1) (CA) 3 MO X X X X X(1) X X _X__ MC-1592-1.1 Cent. Charging Pumps (IA, IB) (NV) 2 __QU_ NR X X NR X(1) X X X MC-1554-3.1 Component Cooling Pumps (IA1, IA2, IB1, 1B2)(KC] 3 QU NR X X X X(1) X X X MC-1573-1.0 4 l Control Area Chilled Water Pumps (CRA-P- 1,2) (YC) 3 QU NR X X X X(1) X X(4) X_ MC-1618-1.0 l D/G Fuel Oil Transfer Pumps (IA, IB) (FD) 3 QU NR - -

X X(1) - -

X MC-1609-3.0 D/G Room Sump Pumps (IA2, IA3, 1B2, IB3)(WN) 3 QU NR - - - - - -

X MC-1609-7.0 NOTES 4l 1. Vibration to be measured with portable instrumentation (Accuracy + 11%).

l

2. Pump contains no bearings, but is close coupled, therefore motor bearing will be monitored.
3. Pump is close coupled, therefore motor lubricant level will be observed.

4l 4. No instrumentation is installed to measure bearing temperature.

LEGEND X - Instrumentation MO - Monthly QU - Quarterly

-- Instrumentation not available NR - Not required for IWP Compliance ( ) - Note I.1-4 McC E - UNIT 1 Revisi

4 I

J s

l 1

DUKE POWER COMPANY.

,i

}

j MCGUIRE NUCLEAR STATION I

i VALVE INSERVICE TESTING PROGRAM i

i ,

i j

Introduction:

! The inservice testing of ASME Code categories A, B, C, and D valves will be j tested as required by Section XI, subsection IW, of the ASME Boiler and i Pressure Vessel Code 1980 Edition except where specific written relief has l been granted by the Commission.

f l

3 '

1 5

j i

i i

i i

i l l

i 1

i 1

1 I

i i l i

1 1

l McGUIRE - UNIT 1 11,1_1 i

.. i

.i 4

TABLE OF ABBREVIATIONS CLASSIFICATION Duke System ANS Valve Designed For Safety Class Code Design Criteria Seismic Loading Class A Class 1, ASME Section III, 1971 Yes 1 B Class 2, ASME Section III, 1971 Yes 2 C Class 3, ASME Section III, 1971 Yes 3 D Class 2, ASME Section III, 1971 No 2 E ANSI B31.1.0 (1967) No NNS F ANSI B31.1.0 (1967) Yes NNS G ANSI B31.1.0 (1967) No -

H Duke Power Company Specifications No -

TEST REQUIREMENTS LT - Leak Test MT - Movement Test Q - Quarterly CS - Cold Shutdown RF - Refueling Outage CT - Cycle and time SP - Setpoint PC - Procedure Check VS - Valve Seating O

McGUIRE - UNIT 1 II.2-1

l I

DEFINITIONS OF TESTING REQUIREMENTS AND ALTERNATIVES j u

Cold Shutdown (CS) Testing will be performed when the unit is in a cold shutdown (Mode 5) whose planned length is of sufficient duration to establish necessary test conditions and to perform the test. In the case of frequent shutdowns, the testing will not be performed more than one per three (3) months.

Testing will commence as soon as the cold shut-down condition is achieved but not later than 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after shutdown, and continue until 4 complete or the plant is ready to return to power. Completion of all valve esting is not a prerequisite to return to power. Any testing not completed at one cold shutdown will be per-formed during any subsequent cold shutdowns that may occur before refueling to meet the code-specified testing frequency.

Cycle and Time (CT) Valve will be tested to verify that its stroke time is less than the maximum allowable stroke time specified by McGuire Nuclear Station.

Leak Test (LT) Valve will be tested to verify that the seat leakage is limited to a specific maximum amount.

Movement Test (MT) Valve will be tested to verify that the valve is operable and/or the valve moves to the position required to fulfill its purpose. No timing is involved.

Quarterly (Q) Testing will be performed at least once per three (3) months.

Refueling Outage (RF) Testing will be performed when the unit is shut down for refueling (Mode 6). Safety valves will be tested periodically per the testing schedule defined in ASME Subsection IWV-3510.

Refueling Outage (RF*) Valve will normally be tested during refueling outages, however, testing is not required more often than once per 24 months per Appendix J to

/'"s. 10CFR50.

k)3 Setpoint (SP) Valve will be tested to verify that it will relieve pressure at its specified setpoint.

McGUIRE - UNIT 1 II.3-l' Revision 4

GENERAL RELIEF TEST REQUIREMENT: Perform trend analyses on category A and B valves as described in IW-3417(a).

BASIS FOR RELIEF: Trend analyses performed on rapid acting valves does not give reliable indication of valve stroke time deterioration.

TESTING ALTERNATIVE: Trend analyses will not be performed on valves that normally operate with cycle times of less 4

than 5 seconds. Maintenance will be initiated if valve time exceeds max. limit.

O l

l O

McGUIRE - UNIT 1 II.4-1 Revision 4

.. - . - . . _ _ = _ - - . - . - . . . _ . - . _ . - - . - . _ _ - - - - - _ . - . . _ _ - . _. . _ _ - _ _

i i

e SYSTEM: ANNULUS VENTILATION 4

FLOW DIAGRAMS: MC-1564-1 i i i '

l i

i s

I l

t a

i l

1 i

l,

,t i

.i 1

l j

i ,

4 i.

1 I

I i

1 1

i i

i t

4 r

4 I

i I

G McGUIRE - UNIT 1 II.5 l 4

- . .__,,-___-..._..._---_.-_---..-.__-..-.._.---___...___.-._._-._-.____-.-_.,___,_.-.._._....i

l l l l n

o i

t t a 2 i l - s i 5 i t v n I e e I R V

s u

l s u k n r n a A m e

R

e e m v v e i i t s s s s s y a a S P P

)3%83Q c wd%$

m $ $l* Yd$

T T T myE01s# $$ L L Q Mq y D r

o g

e C X t

a C

B X X X e

v l

a A X X V

3 3 4 4 2 m3aY oO - - - - -

1 1

I I G G J r

e b

m u

N 1 1 1 1 1 g 4 4 4 4 4 n 6 6 6 6 6 i 5 5 5 5 5 w 1 1 1 1 1 a - - - - -

r C C C C C D M M M M M m$U B B B B B 1

T I

N r U

_ e -

b m E u R

_ N A I 0 1 A B A U e 1 1 S 6 8 G v - - - - - c l E E E _. E E M a V V V V V V I I I _

I I l l l l 4 4 4 4

l l

I G

l 1 i l 1

,1 t

(

(RELIEF FOR VALVE IVE-11) i PAGE DELETED 4

O ,

,i i

i i

l l

l

l 1
l II.5-3 McGUIRE - UNIT 1 Revision 4 l

1 I

i SYSTEM: AUXILIARY FEEDWATER FLOW DIAGRAMS: MC-1592-1.0 MC-1592-1.1 i

I i

i

)

4 t

1 McGUIRE - UNIT 1 II.6-1 ,

1 1

r -

e e e e e O

t m m -

m m a i i i i w t t . t t 2 d e g g e .

e g g e m m m 6 e i n n i i n n F t i i t t i i 1 t t t t 1 y e a a e e a a r l r r l l r r a c e e c c e e p

i y p p y y p l s c o o c c o o i k x r . . . . . . .

u a x x x x x x x A m a a a a a a a e m m m m m m m R . .

m c c c c c c c e e e e e e e e t s s s s s s s s

y 0 0 0 0 0 0 0 S 6 1 1 6 6 1 1 S S

$IE0"*E!a I I S C C C O:?a m3T* X X X X X X

$ES3?a u:

T T T T T T T T T T C M C C H C C C H C y D r

o O

g e C X X X t

a C

B X X X X X X X e

l v

a A V

1 1 1 1 1 4 4 7 6 7

%5 E 8" - - - - - - - - - -

G 1 I J K L C D C G 1

r e

b m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 2 2 2 2 2 2 2 2 2 2 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M C B B B B C C B B B 1 E3" T

I N

r U e

b -

m u E N A A A A R UO 2 6 5 4 6 8 7 4 I 0 1 e 6 6 6 6 6 6 5 5 5 5 v - - - - - - - - - - G l A A A A A A A A A A c a C C C C C C C C C C M V I I I I I 1 I I I I

t

~

r d e t

% a w 3 d e e e e e e -

e m m m m m m 6 e i i i i i i F t t t t t t I I

y e e e e e e

. r l l l l l l a c c c c cy c i y y y y y l

i k s c c c c c c x r . . . . . .

u a .

x x x x x x

. A m a a a a a a e m m m m m m R

m c c c c c c e e e e e e e

- t s s s s s s s

y 0 0 0 0 0 0

_ S 6 6 1 1 6 6

$Yf.d# ?U0 S C

S C

S C

S C

X X X X X X X X 0ae M o#

0 58 a?e uE" T M

T C

T C

T M

T C

T C

T M

T C

T C

T M

y D r

- o g

e C X X X X t

a C

B X X X X X X e

l v

a A V

1 4 4 7 7 1 9 8 8 8 8 1 1

%328" 1 1 K C C D G H K G 1 1

r e

b m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 2 2 2 2 2 2 2 2 2 2 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M H EM B C C B B B B C C B 1 T -

I N

r U e -

b -

m _

J u E N B B R 3 2 4 5 6 0 9 8 0 1 I

( % e v

5 5 4 4 4 5 4 4 4 4 U

- - - - - - - - - - G l A A A A A A A A A A c a C C C C C C C C C C M V 1 I I I I I I I I I 4 , j

l r

e t

a w 4 i d e e e e e e - s e

e i m i m

i t

m i

m i

t m

i t

m

6. vi F t t t I e I R y e e e e e e r l l l l l l a c c c c c c i y y y y y y l s c c c c c c i k x r . . . . . .

u a x x x x x x A m a a a a a a e m m m m m m R . . . .

m c c c c c c e e e e e e e t s s s s s s s

y 0 0 0 0 0 0 S 1 1 6 1 1 1 SY2e" * ?U$ S C

3:EE 3 $" X X T T T T T T T T T T 358U?e u$ C C M C C M C M C M y D r

o g

t e C X X X _ X a .

C B X X X X X X e

l v

a A V

4 4 4 0 1 1 1 1 1 1 3 4 5 5 1

$%3 E 8" J J

K L

C B

B C

C B

r e

b m 0 0 0 0 1 1 1 1 1 1 u . . . . . .

N 1 1 1 1 1 1 1 1 1 1 g 2 2 2 2 2 2 2 2 2 2 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M E3" B B B C C C C C C C I T

I N

r U e -

b m E u R N B B B A 2 8 7 6 8 2 1 0 8 f e 4 3 3 3 1 1 1 1 9 8 G

v - - - - - - - - - -

c l A A A A A A A A A A a C C C C C C C C C C M V I I I 1 I I I I I I l

4

O O O 0 $ System: Auxiliary Feedwater E O E B E E

a  ? d

%  ? e 3 & -  ?

@ Z Valve' Category u O U d

U 8

u H E Y E

H Valve Number Drawing Number A B C D Remarks ICA-7A C MC-1592-1.1 B-10 X CT 10 sec. cycle time ICA-15A C HC-1592-1.1 D-3 X CT 10 sec. cycle time 4 1CA-86A C MC-1592-1.1 C-13 X CT 10 sec. max. cycle time 4 1CA-116B C MC-1592-1.1 E-13 X CT 10 sec, max. cycle time ICA-26 C MC-1592-1.1 I-4 X MT ICA-27 C MC-1592-1.1 I-3 X CT X 60 sec. max. cycle time i

ICA-32. C MC-1592-1.1 I-7 X CT X 60 sec. max. cycle time ICA-31 C MC-1592-1.1 I-7 X HT ICA-22 C MC-1592-1.1 I-10 X MT ICA-20 C MC-1592-1.1 I-11 X CT X 60 sec. max. cycle time I

McGUIRE - UNIT 1 ~

Revision 4

r t

d e

a w

e e 6

O e m m 6 e i i I

F t t I

y e e r l l a c c i y y l s c c i k x r . .

u a x x A m a a e m m R

m c c e e e t s s s

y 0 0 S 1 1 F F

$UEtd# Ig$ R R X X E" ?$ tj$

$ESt?5 g$ T T T T C C M M y D r

o t

g e

a C X X O C

B X X e

v l

a A V

a%$g$ 4 4 8 7 1 1 D D C F r

e b

m 1 1 1 1 u . . . .

N 1 1 1 1 g 2 2 2 2 n 9 9 9 9 i 5 5 5 5 w 1 1 1 1 a - - - -

r C C C C D M M M M 1

mgU C C C C T

I N

r U e -

b m E u R N

l v

e 1

6 1

A 2

6 1

A 5

6 1

A 6

6 1

A IO U

G M

c a C C C C V I I I I

i i

$ MC-1592-1.0 i

a i

{

VALVE: ICA-60, ICA-64, ICA-56, ICA-52, ICA-44, ICA-48, ICA-40, ,

ICA-36 l
CATEGORY: B i

CLASS: C l

t j FUNCTION: Control aux, feedwater flow to S/G's.

i 1

TEST REQUIREMENT: Full stroke exercise and stroke time quarterly BASIS FOR RELIEF: Valves can only be timed when aux, feed receives an auto-start signal

} ALTERNATE TESTING: Valve will be full stroke execised quarterly and I timed during ESF testing.

i i

i

}

i J

i i

1 1

i t

b i

t j

i t

i i

i i

i l McGUIRE - UNIT 1 II.6-7

.w,e -_c.7, ._ . . . , . ,. . ., , ,, ,

4k MC-1592-1.0 k VALUE: ICA-61, ICA-53, ICA-45, ICA-37, ICA-65, ICA-57, ICA-49, ICA-41 CATEGORY: C CLASS: B FUNCTION: Check flow from steam generators to aux. feedwater TEST REQUIREMENT: Full stroke exercise quarterly BASIS FOR RELIEF: Flow through these valves would unnecessarily thermal shock the S/G and feedwater piping.

ALTERNATE TESTING: Valves will be full stroke exercised at cold shutdown.

l O

O II.6-8 McGUIRE - UNIT 1 Revision 4

MC-1592-1.1 i

VALVE: ICA-20, ICA-27, ICA-32 CATEGORY: B l

CLASS: C FUNCTION: Maintains minimum flow for Auxiliary Feedwater Pumps.

TEST REQUIREMENT: Full stroke exercise and stroke time quarterly BASIS FOR RELIEF: This valve automatically regulates to maintain the minimum flow through the pump by monitoring the flow on the suction of the pump. There are not sufficient manual controls on this valve to permit the desired testing.

These valves will operate during testing of the pump and 3 their operability will be verified then.

ALTERNATE TESTING: These valves will be full stroke exercised quarterly and stroke timed during ESF testing.

I McGUIRE - UNIT 1 II.6-9 j

MC-1592-1.1 VALVE: ICA-165, ICA-166 CATEGORY: C CLASS: C 4 FUNCTION: Prevents backflow from Aux. Feedwater System to Nuclear Service Water System TEST REQUIREMENT: Full stroke exercise quarterly BASIS FOR RELIEF: Flow cannot be put through these valves because this would contaminate the aux, feed system with raw water.

ALTERNATE TESTING: Valves will be verified operable during refueling 4 outages by disassembly.

O O

McGUIRE - UNIT 1 II.6-10 Revision 4

I i 1 i .

)

1 1

i SYSTEM: Boron Recycle J

FLOW DIAGRAMS: MC-1556-3.0 l

j

)

i i 1 i

i I

}

i 1

1 i

j 3

1 l

t I

i i

l I

i 1

i I.

1 1

i 1

i 1

O McGUIRE - UNIT 1 II.7-1

-w - - - -- -- ,m. e- . . , ., _ _ . _ . _ . _ _ . . - _ __ _

2 O

e c 7 l e 1 c s 1 y

c 0 e 1 R $

n s e o k m r r i o a t B m e n R o

i m t e a t l s o y s S I

$tg$d* E$gH F F R R m $a& mOgm X 3g0a?& ugh TT TT CL ML l

y D r

o C

g e

t a

C X O

B e

l v

a A X X V

5 3 a%5Eo o G G

r e

b m 0 0 u

N 3 3 g 6 6 n 5 5 i 5 5 w 1 1 a - -

r C C D M M E3u B B 1 T

I N

r U e

b -

m u B E N 0 2 R l

e v

a 6

2 B

N 5

2 B

N

- UO I

G M

c V I I _

J 4

MC-1556-3.0 l'

VALVE: INB-262 i

CATEGORY: A, C

. CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Leak rate performed every 24 months will verify valve closure.

i 4

i I

I i

i i

l t

l l

McGUIRE - UNIT 1 .II.7-3 I

I

! e 1

SYSTEM: BREATHING AIR FLOW DIAGRAMS: MC-1605-3.I i

l l

l l

l l

i i

1 i

I I

1 i

l I

l, I

i McGUIRE - UNIT 1 II.8-1

2 O

r . 8 i c A e I s I g

n 5 i 1 h

t s e a k m e r i r a t B m e n R o

i m t e a t l s o y s S I

$u$63Q w3%$ F R

F R

X

. $ al* %d$

T T T T

.$En1E* M$ CQL MQL y D r

o C

g e

t a

C X O

B e

v l

a A X X V

2 4 G E 3EM oO r

e b

m 1 1 u . .

N 3 3 g 5 5 n 0 0 i 6 6 w 1 1 a - -

r C C D M M 1

.EU B B T

I N

r U e -

b m E u R N B T l

e v

9 4

B 0

5 B

- UO G

M c

a V V V I I

. . . . . - . ...- -. - _. .. .. - .. . . . ~ - .. ..

f i

i

! MC-1605-3.1 i

l

}

! VALVE: IVB-50 1

CATEGORY: A, C 4

l CLASS: B

. FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per 3 months.

i l BASIS FOR RELIEF: The system design does not provide any indication for j verifying valve closure upon flow reversal.

1 i ALTERNATE TESTING: Leak rate test performed every 24 months will verify l valve closure.

i -

i i

i i

i i,

t

}

i I

}

1 4

i i

i 2

t

! McGUIRE - UNIT I II.8-3

SYSTEM: CHEMICAL & VOLUME CONTROL SYSTEM FLOW DIAGRAMS: MC-1554-1.1 j

MC-1554-1.2 MC-1554-1.3 MC-1554-2.0 MC-1554-3.0 MC-1554-3.1 O

McGUIRE - UNIT 1 g ,9,

l o

r t

n 2 e e e e e e -

o _

m c

c m m 9 C m m _ c m i i i i e e e i i t t e t t t s s s t I I

m e e e 5 5 e e e u l 5

1 1 1 l l l l l l c o c c c $ $ $ c c y y y y y V y c c s c c c e e e c d k .

m m m . .

n r . .

x i i i x

x x a a x x a t t t a a a m a a m m l e m m m n n n m a R .

o o o . .

c i i i .

c c

c t t t c c c i

e e e a a a e e e m s s s s e s s l l l h o o o 0 0 _

C 0 0 0 s s s 0 1 1 1 1 6 I I I 1 m

e S S t #D8UM S C s C C S

y ?UE X X X X X E:ae ~ N$"  ! _

T T T T T T T T T T T OESM?& u$ C C M C M C C C C C C y D r

o g

e C X t X a

C X X B X X X X X X X e

v '

l a A V

l 0 3 3 5 5

%B 2 O" 1 1 l 3 3 7 7 7 1 J 1 1

F E C I J K J C D r

e b 2 2 m 1 1 2 2 2 2 u . . 2 2 2 .

1 1 N 1 1 1 1 1 1 1 1 1 g 4 4 - - - 4 4 4 4 4 4 n 5 5 4 4 4 5 5 5 5 5 5 i 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1 1 w 1 1 1 1 1 1 1 - -

a - - 1 1 - - - -

C C r C C - - - C C C C D M M C C C M M M M M M M

M M

_ I

$M B B B B B B A A B A A T I

N r U e -

b m E u A A A R N A B A 7 8 9 4 5 2 1 2 5 5 5 B A A f e 9 9 1 2 2 4 4 4 7 1 2 v - - - - - - - - - - - G l V V V V V V V V V V V c a N N N N N N N N N N N M I I I I I V I I I I I I 4

4

3 r

())

E System: Chemical and Volume Control E O 2

a  ? #

%  ? & 2 3 & ~ ?8 E 2 Valve Category u 0 2U d

o 0 E Y $"

Valve Number Drawing Number " H " h A B C D Remarks f

INV-24B A MC-1554-1.2 D-6 X CT 60 sec, max. cycle time INV-1013C E MC-1554-1.3 F-12 X CT 30 sec. max. cycle time j INV-1012C- E MC-1554-1.3 F-12 X CT 30 sec. max. cycle time lNV-844 E MC-1554-1.3 F-5 X MT INV-1007 B MC-1554-1.3 F-13 X MT X CS INV-1008 B MC-1554-1.3 F-13 X MT X CS INV-1009 B- MC-1554-1.3 F-14 X Mr X CS INV-1010 B MC-1554-1.3 F-14 X MT X CS I

McGUIRE - UNIT 1 II . 9-2a

, Revision 4 New Page

l t

o r

n o e e e e i

t e

m g

i t

e m

g 3

9 C m m m m 9 i i i i n n e t t t t i i I m t t I u e e e e a a l l l l l r r o c c c c e e V y y y y p p i

s c c c c o o t k n r . . . . . .

a a x x x x x x m a a a a a a l e m m m m m m a R c . . . . . .

i c c c c c c m e e e e e e e s s s s s s h

C 5 5 0 0 0 0 1 1 1 1 1 1 m

e 82jed#

t F S S S S s

y E$ $" R C C C C S

3?& ~OY* X X X X X T TT TT T T T T 058a?a u$" C LC LM C C C C y D r

o g

e t

a C X O C

B X X X X X e _

v l

a A X X V

0 2 8 1 8 7 8 9 a%5. 38" F F

B B

K F K r

e b

m 3 3 3 0 0 0 0 u

N 1 1 1 2 2 3 3 g 4 4 4 4 4 4 4 n 5 5 5 5 5 5 5 i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 a - - - - - - -

r C C C C C C C D M H M M M M M 1

E3u B B B B B B B T

I N

r U e -

b C, C, m E u A A 2 A B A B N 2 9 0 1 2 4 5 4 4 0 4 4 4 4 e 8 8 1 1 1 2 2 v - - - - - - -

c l V V V V V V V M a N N N N N N N V I I I I I 1 I

r ,

Ol t C

o r

n o

e m

e m

4 i 9

4 s

n o

i e

i i v t t 1 e

m 1 R u e e l l l o c c V y y l

s c c e k n r . .

a a x x m a a l e m m a R c . .

i c c m e e e s s h

C 0 0 1 1 m

e t

s e?%Ee E S C

S C

y wSg$

S

$$?*%g$ X X X X X E $05l* g$ T T T T T T T C C M M M M M y D r

O C o

g e

t a

C X X X X X B X X e

l v

a A V

0 0 1 1 2 6 1 1 5 e32agO 1 1 1 I E E F F r

e b

m 1 1 1 1 1 1 1 u . . . . . . .

N 3 3 3 3 3 3 3 g 4 4 4 4 4 4 4 n 5 5 5 5 5 5 5 i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 a - - - - - - -

r C C C C C C C D M M H M M M M 1

em U B B B B B B B T

I N

r U e -

b m E u B A R O N l

e v

2 2

2 V

1 2

2 V

3 2

2 V

7 2

2 V

3 3

2 V

1 3

2 V

5 2

2 V

1 1

1 G

M c

a N N N N N N N V I I I I I I I 4

MC-1554-1.1 VALVE: INV-94A, INV-95B CATEGORY: B CLASS: B FUNCTION: a) Provide containment isolation b) Reactor coolant pump seal water discharge line.

TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: Closure of one of these valves during unit operation would inhibit normal seal water flow across the reactor coolant pump number 1 seal. This action could result in damage to the reactor coolant pump seals or the pumps themselves.

ALTERNATE TESTING: Valves will be cycled and timed during cold shutdowns.

O l

l O

McGUIRE - UNIT 1 II.9-5

MC-1554-1.2 VALVE: INV-7B CATEGORY: B CIASS: B I 3 FUNCTION: Letdown containment isolation.

l i

TEST REQUIREMENT: Full stroke exercise and stroke time quarterly t i

BASIS FOR RELIEF: Failure of this valve in closed position could re'sult 4 in loss of PZR level control and could result in a plant shutdown. I i

j ALTERNATE TESTING: Valve will be exercised and times at cold shutdown. l I

j h

J i ,

r 5 ',

1 J e J

t I

t

\

[, r ,4

/

. re-.

i i

c s-g/ . . .

McGUIRE - UNIT 1 . II.9-6 .

Revision 4 6

t

. - , . . - . . . . - - - . ,A..-. . _ . - , . _ , , . . . . , . ,_._.r_,, _ - . . . - , _ ,,m,_,.w, -,rs_,,-.. r . . . _ , . -.m. __.yg'_

I 1

MC-1554-1.2 VALVE: INV-1A, INV-2A CATEGORY: B CLASS: A FUNCTION: Isolate regenerative heat exchanger TEST REQUIREMENT: Cycle and time every three months BASIS FOR RELIEF: Failure of this valve in closed position could result in loss of pressurizer level control ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown

(

l 9 i

l l

l McGUIRE - UNIT 1 II.9-6a Revision 4 New Page

e i

1 j

4 4 l 1

i MC-1554-1.3 l

l 1

I VALVE: INV-1002 js CATEGORY: A, C i i 2

CLASS: B FUNCTION: Provides containment isolation {

! i l TEST REQUIREMENT: Full stroke exercise quarterly l

j - -- BASIS FOR RELIEF: There is no indication of valve closure.

ALTERNATE TESTING: Valve will be verified closed by leak rate test

! performed in accordance with Apperdix J.

E'

,I ..

, d.

i 4

i 4,

1 i

t i

l 4-1 i

/

a p

i:

1 j

McGUIRE - UNIT 1 11,9 7

MC-1554-1.3 O

VALVE: 1hT-1007, lhT-1008, lhT-1009, lhT-1010 CATEGORY: C CLASS: B FUNCTION: Opens on flow from standby makeup pump to reactor coolant pump seals.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: These valves cannot be full or partial stroked during power operation as this would increase boron inventory in the RCS and could result i.. a unit shutdown.

ALTERNATE TESTING: Valves will be full stroked at cold shutdown.

O 1

O 1

l McGUIRE - UNIT 1 II.9-7a Revision 4 New Page l

'g MC-1554-2.0 i

i i VALVE: INV-141A, INV-142B i

CATEGORY: B

! CLASS: B 1

i FUNCTION: Isolates volume control tank upon receipt of a safety

. injection signal.

i l TEST REQUIREMENT: Cycle and time valve every three months.

1 BASIS FOR RELIEF: Closure of one of these valves would isolate the suction i for the charging pumps. This action could result in

] damage to the charging pumps. Seal water for the reactor 4

coolant pumps would also be inhibited. This is undesirable in that damage could be done to the seals.

4 ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

J l \

se i

i I

i I

1

'l l,

i i

i <

l I

McGUIRE - UNIT 1 II.9-8  !

Revision 4 l l

MC-1554-3.0 VALVE: INV-244A, INV-245B CATEGORY: B CLASS: B FUNCTION: Isolates charging to the Reactor Coolant System upon receipt of a safety injection signal.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: If one of these valves were to fail in the closed position during testing, normal and alternate charging I w uld be lost. This could result in a loss of pressurizer 4l level control and could result in a plant trip.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

O O

l McGUIRE - UNIT 1 II 9~9 j Revision 4 l l

1

l MC-1554-3.1 j 4 VALVE: INV-225, INV-231 f CATEGORY: C i 1

! CLASS: B l FUNCTION: Opens on flow from the Centrifugal Charging Pump (s).

i TEST REQUIREMENT: Verify proper valve movement every three months.

i BASIS FOR RELIEF: Valve cannot be full or partial stroke exercised during power operation or cold shutdown because this would result in an increase in the RCS boron

. inventory and could result in a plant shutdown.

4, Full stroke exercising during cold shutdown could result in a low temp. overpressurization of the RCS.

ALTERNATE TESTING: Valve will be full stroked during refueling.

1 4

4 l

I i

1 McGUIRE - UNIT 1 II.9-10 Revision 4

MC-1554-3.1 4 VALVE: INV-223 CATEGORY: C CLASS: B FUNCTION: Opens on flow alignment from FWST TEST REQUIREMENT: Verify proper valve movement every three months.

BASIS FOR RELIEF: Testing of this valve requires opening INV-221A or INV-222B. Failure of one of these valves in the open position aligns the FWST to the suction of the charging pumps with no means of isolating the flow path. This would result in an increase in boron inventory in the 4 RCS and could result in a plant shutdown. Full stroke exercising at cold shutdown could result in a low temperature overpressurization.

ALTERNATE TESTING: Valve will be partial stroked during cold shutdowns and full stroked during refueling.

O O

McGUIRE - UNIT 1 Revision 4

MC-1554-3.1 4

O l VALVE: INV-221A, INV-222B

CATEGORY: B CLASS: B

~

FUNCTION: Aligns fueling water storage tank (FWST) to the suction of the centrifugal charging pumps upon receipt of a safety

injection signal.

4 TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: If one of these were to fail in the open position during testing, the FWST would be aligned to the suction of the 4

charging pumps. This would result in an increase in RCS Boron inventory and could result in a plant shutdown.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

1

\

McGUIRE - UNIT I II'9"I2 Revision 4 '

! SYSTEM: COMPONENT COOLING FLOW DIAGRAMS: MC-1573-1.0 MC-1573-1.1 MC-1573-3.1 l MC-1573-4.0 ,

I l

I l

1 l

l II,jo_1 McGUIRE - UNIT 1

i l

g n

o e

m e

m e

m e

m e

m e

m

~ e o i i i i i t

i t

C t t t t t e e e e e e n l l l l l c

l c

e c c c c y y n y y y y c c o s c c c c p k m r . . . . .

x o a x x x x x C m a a a a a a e m m m m m m R . . .

m c c c c c c e e e e e e e t s s s s s s s

y 0 0 0 0 0 0 1 1 S 6 6 5 5

$2yUy #t" H a E?e ~aQd A Bg@d?a uyH T T T T T T T T T T C C C C M M M M C C y D r

o G

g e C X X X X t

a C

B X X X X X X e

l v

a A V

1 1 0

" MS?o U 7 8 7 8 4 4 1 1 5 1 C C C C F F F F J J r

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 3 3 n 7 7 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M 1

jO C C C C C C C C C C T

I N

r U e -

b m E u

N l

V e

v a

A 1

C K

I 8

2 C

K 1

A 3

C K

1 B

8 1

C K

1 5

C K

1 8

C K

I 1

1 C

K 1

4 C

K 1

1 A

1 5

C K

1 4

5 C

K 1

- W c

M

g n 3 i

l e e e e e e e e 0 o m m m m m m m m 1 o i i i i i i i i .

C t t t t t t t t I I

t e e e e e e e e n l l l l l l l l e c c c c c c c c n y y y y y y y y o s c c c c c c c c p k m r . . . . . . . .

o a x x x x x x x x C m a a a a a a a a e m m m m m m m m R . .

m c c c c c c c c e e e e e e e e e t s s s s s s s s s

y 0 0 0 0 0 0 0 0 S 6 4 6 4 6 6 6 6 s 605 w0g U$s* %3 0 E01l" g T T T T T T T T C C C C C C C C y D r

o (U g e

t a

C C

B X X X X X X X X e

v l

a A V

3 7 7 8 8 2 6 1 9 m3a&g K K K K E D F D r

e b

m 0 0 0 0 1 1 1 1 u . . . .

N 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 n 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M M M M M M M M ag -

1 C C C C C C C C T _

I _

N r U -

e -

b _

m E u A B R

N A 0 B 8 A A B B C( l e

v 0

5 C

3 C

2 3

5 C

2 2

C 6

5 C

7 5

C 8

C 1

8 2

C I

U G

c a K K K K K K K K M V I 1 I 1 I 1 1 1

$ U System: Component Cooling 5 E E B : 0

% a a d

  1. ? e 3 & ~  ?

E 13 Valve Category u O U M O E U $

" # H Remarks Valve Number Drawing Number A B C D 1KC-424B B MC-1573-3.1 L-4 X LT X CS Isolation time $40 sec.

CT 1KC-425A B MC-1573-3.1 L-6 X LT X CS Isolation time $40 sec.

CT IKC-279 B MC-1573-3.1 K-4 X X LT X RF NT 1KC -315B B MC-1573-3.1 L-13 X CT Isolation time $30 sec.

IKC-305B B MC-1573-3.1 D-14 X CT Isolation time $30 sec.

IKC-340 B MC-1573-3.1 E-12 X X LT X RF HT 1KC-338B B MC-1573-3.1 D-12 X LT X CS Isolation time $40 sec.

CT 1KC-320A B MC-1573-3.1 C-10 X LT X CS Isolation time 515 sec.

CT II.10-4 McGUIRE - UNIT 1 O O O

m

, \ ( '

?

O U System: Component Cooling O c

!  : 0

O a *

,  %  ? &

d & ~  ?

E 3 Valve Category u d U i

3 o

8 $

H Y

Valve Number Drawing Nmnber A B C D Remarks 1KC-322 B MC-1573-3.1 C-9 X X LT X RF MT l IKC-280 B MC-1573-3.1 D-1 X X LT X RF MT 1

1 1KC-332B B MC-1573-3.1 D-1 X LT X CS Isolation time $15 sec.

CT a IKC-333A B MC-1573-3.1 G-1 X LT X CS Isolation time $15 sec.

! CT l

4 IKC-47 B MC-1573-4.0 L-12 X X LT X RF MT IKC-429B B MC-1573-4.0 K-12 X LT Isolation time $15 sec.

CT 1KC-430A B MC-1573-4.0 K-10 X LT Isolation time $15 sec.

CT II.10-5 McGUIRE - UNIT 1 Revision 4

MC-1573-3.1 O

VAIXE: IKC-424B, 1KC-425A CATEGORY: A CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit the normal flow cath from the reactor coolant pump motor coolers. This action could result in damage to the pump.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

O i

I i

O McGUIRE - UNIT 1 II.10-6

1 1

J MC-1573-3.1 t

l i

VALVE: 1KC-280 i

4 i CATEGORY: A, C i CLASS: B

} FUNCTION: Provides containment isolation and prevents over-i pressurization of line between IKC-332B and 1KC-333A.

}

} TEST REQUIREMENT: Verify proper valve movement.

} BASIS FOR RELIEF: This valve cannot be practically tested during operation l due to the design of the system.

I j ALTERNATE TESTING: Valve will be verified closed by leak test performed 1 in accordance with Appendix J.

I 1

)

4 1

lO

}

j i

4

}

4 i

l.

i i

I t

l

}

l l

1 4

, McGUIRE - UNIT 1 II.10-7 1

1

, - - . , . ,-,---.m.,,- . - , - , , , - - - - , , ,-- -.,..e-r.,, - - .,,- . ------ - -,n.--., - . . . - - a c. - , - - - , , - - - . , , - - . , , ~ - . - . , . . - , , -

i l

l l

MC-1573-3.1 0:

VALVE: 1KC-322 CATEGORY: A, C CLASS: B FUNCTION: Provides Contai~nment Isolation.

TEST REQUIREMENT: Verify valve seats on flow reversal.

BASIS FOR RELIEF: Testing of this valve during operation is prohibited due to the system design.

ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.

O O

McGUIRE - UNIT 1 II.10-8

i l

i i

MC-1573-3.1 i

J I VALVE: 1KC-279

.1 CATEGORY: A, C 4

i CLASS: B

FUNCTION
Provides containment isolation and prevents over-j pressurization of line between IKC-424B and 1KC-425A.

TEST REQUIREMENT: Verify valve seats on flow out of containment.

l BASIS FOR RELIEF: The system design does not provide a means of verifying

! valve closure upon flow reversal.

1

+

i ALTERNATE TESTING: Valve will be verified shut by_ leak test performed in accordance with Appendix J.

L i

l i

i i

t 4

i j

4 l

l

< l j l s

l McGUIRE - UNIT 1 II.10-9

. - - . . - , - - . . -- . , - - - - . , , .----------.-n- - - , - - - - . . . - - - - . - - - - - - - - - ~ . . - - - - . - , , - - - - - - , _ - - - - - - - - - -. .--

l l

l MC-1573-3.1 VALVE: 1KC-340 CATEGORY: A, C CLASS: B FUNCTION: Provide Containment Isolation.

TEST REQUIREMENT: Verify valve seats on flow reversal once every three months.

BASIS FOR RELIEF: The system design does not provide a means of verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.

O O

McGUIRE . UNIT 1 II.10-10

MC-1573-3.1 l i

VALVE: 1KC-338B j CATEGORY: A j CLASS: B i I

! FUNCTION: Provides containment isolation. l 1

TEST REQUIREMENT: Cycle and time valve every three months.

I BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit flow to the reactor vessel support

, coolers. This action could result in damage to the f reactor vessel.

ll ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

i l

i 1

1 1

i 1

i i

i i

i i

i i

4 3

i

McGUIRE - UNIT 1 II.10-11 4

l l

l l

MC-1573-3.1 O

l l VALVE: IKC-332B, 1KC-333A CATEGORY: A CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of one of these valves in the closed position during testing would inhibit the flow path through the reactor coolant drain tank heat exchanger. No alternate flow path is available, which would force unit shutdown 4

until the valve is repaired. Steam would be released to the RCDT which would become overpressurized.

ALTERNATE TESTING: Valves will be cycled and timed during cold shutdowns.

O l

1 O

l II.10-12 McGUIRE - UNIT 1 Revision *,

l i

i

! l f

MC-1573-3.1

. s VALVE: 1KC-320A I l

CATEGORY: A l

! CLASS: B l

FUNCTION: Provides containment isolation. l TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would isolate flow to the reactor coolant drain tank heat exchanger. This failure would require unit 4 shutdowm until the valve could be repaired due to overpressurization of the RCDT.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

I I

r McGUIRE - UNIT 1 II.10-13 ,

Revision 4 l l

l

_ _ _ - . _ _ . .,. . ~ . = - . . - -

MC-1573-4.0 O

VALVE: 1KC-47 CATEGORY: A, C CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Verify valve seats on flow out of containment.

BASIS FOR RELIEF: This valve cannot be pract ically tested during unit operation due to system design. No instrumentation is installed which can monitor any flow past the check valve.

ALTERNATE TESTING: Valve will be verified shut by leak test performed in accordance with Appendix J.

9 O

II.10-14 McGUIRE - UNIT 1

SYSTEM: CONTAINMENT AIR RELEASE AND ADDITION FLOW DIAGRAMS: MC-1585-1.0 i 1

1 l

O O

McGUIRE - UNIT 1 II.11-1

n i

t i

d o

2 1

O d . . . . 1 A c c c c .

e e e e 1 d s s s s 1 n

a 3 3 3 3 5 $ 5 5 e

s s e e e e a k m m m m e r i i i i l a t t t t e m R e n n n n R o o o o r i i i i i t t t t A a a a a l l l l t o o o o n s s s s e I I I I m

n i

a * * *

  • t n e3%E3 F R

F R

F R

F R

C o wSg ng m ty e

t ,

y s 058ag T T T T T T T T g CQL CQL CQL CQL S

y D r

o t

C g

e a

C O B

e l

v a A X X X X V

4 6 6 3 m38ag - - - -

J J E E r

e b

m 0 0 0 0 u

N 1 1 1 _ 1 g 5 5 5 5 n 8 8 8 8 i 5 5 5 5 w 1 1 1 1 a - - - -

r C Cl C C D  !

t t

?

?

eg B B B B 1 T

I N

r U e

b -

m u E R

N l

e v

a A

1 Q

V B

2 Q

V B

5 Q

V A

6 Q

V 6

U G

f F

c V I I I I

SYSTEM: CONTAINMENT AIR RETURN EXCHANGE AND HYDROGEN SKIMMER FLOW DIAGRAMS: MC-1557-1.0 l

\

.O O

McGUIRE - UNIT I II.12-1

e e _

e g

i t

m g

i t

m g

2O 2

1 n c c

n n .

a e h e i i 1 c s s t t 1 x a a E 5 5 r r 5 $ e e p p n e e o o r s ur k m m .

t e r i i .

em a t t x x Rm m a a i e n n m m rk R o o iS e e i i c

c A v v t a

t a e e n i i s s t e s s l l ng s s o o eo a a s s 0 0 mr P P I I 6 6 nd i y al i t

nd a3%E3N F on wSg$ R C a 3 g$

X m 13$

e t

s y

358ag$ T T T T T T T T T T S g$ L L MQL CQL CQL CQ C" y D r

o i O

g e C X t

a C

B X X e

l v

a A X X X X X V

2 3 2 2 1 3 3 1 1 2 1 m32agO K K J J J I I r

e b

m 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 g 7 7 7 7 7 7 7 n 5 5 5 5 5 5 5 i 5 5 5 5 5 5 5

_ w 1 1 1 1 1 1 1 a

r C C C C C C C D H M M M M  :

I M

. .gU B B B B B B B 1 T

I N

r U e

b -

m E u R N A B l

e v

a 4

3 X

V 0

4 X

V 0

3 X

V 1

3 X

V 3

3 X

V A

1 X

V B

2 X

V

- IO U

G M

c V I I I I I I I

MC-1557-1.0 i

f I I

j. VALVE: IVX-30 l

' j i

j CATEGORY: A, C i

. CLASS: B 1

4 FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

! BASIS FOR RELIEF: The system design does not provide any indication for j verifying valve closure upon flow reversal. '

ALTERNATE TESTING: Valve will be verified shut by leak test performed

) in accordance with Appendix J.

4 h

j l

l 1

)

1 i

i 1

i J

i i

1 d

l O

1 McGUIRE - UNIT 1 II.12-3

..r

/
'

l 1

j SYSTEM: CONTAINMENT PURGE VENTILATION i.

j+ FLOW DIAGRAMS: MC-1576-1.0 i.

1 1

i 1

1 4

1 1

4 i, .,

i t

4 , . \ .i l \s '

g s

\ \

s s k

i t,

, i.

'1 .s s 4

3 s, , \ , e.' is s' \>

) ( /' \ \ '>

s~

( 'i' r .

3l , t

\

t s

.t

, J.

  • ^

l I i d

- ,i ) ,

\.

11 1 (c

+s

.s s

c' s. , .

. 1- ..

s T h .

. , , e

,! , s '\ '+

.,, t._- g i

t \

\

..', )

1

.s

- \ \Sa 'n N 1

g

,! s -

1

, s. s . s -, ,

j  ! ,,' 3. ; N. N. i 1 i s .

's ,

j s \ ,  ;

s '-

  • N , y 3, --

s , ,

, \

tc 1 s

't j

,' i (. 3 g w. 1

\. \s d

,\ , - N s i ' - ; ,,

'l j- \ <

4 .r u j ,.

' ', Ns - 't -

s ' i. i }. / . 4 i ,

\s

\ )- y i s, i w , , ' , \' '- ,

1 k

s g \

4 e s

' ' - \s s i 1- , c 5

3 g - t \ --

j

. s
3. ) c s..

Ts' .

, , -s i s l'

.c \. _ \ -

l ,'s , s:

s ' ,.

~

. ,c s s.

i, i l i

. is.

', s

\ ', ,

4 \i '. . s .3 .,

. . s.s y.1 t, s s

s, i l

l

t. , >

4 r g s j f

. ,{.s). .

< ' q -.

( ,s. s-i s . s';

i s m., .. . ,

t q ;. ' f. v' 5

I,I.13-1 McGUIRE - UNIT 1 ~,..,-

g, . s

. i 3n , >~ 3 m ' yN s) l i - y

- , \  %

, s. ,

\ . .

' 2 'a' 3

r s

b

,NT- .s t w 2.

N

, .y, .  % ; q,y( y%.3-3 ,

n i

t l

o a

2 3

1 O-i t c c c c c c .

n e e e e e e I e s s s s s s I V 3 3 3 3 3 3 e 5 5 5 5 5 5 g

r s e e e e e e u k m m m m m m r i P i i i i i t

a t t t t t t m n n n e n n n n e R o o o o o o i i i m i i i t

n t t t t t a a i a a a a a l l l l l o

l o

t o o o o n s s s s s s o I I I I I I C

m e o3%E3$ F R

F R

F R

F R

F R

F R

t w5g$

- s y $:gN S X X X X X X t3N T T T T T T T T T T T T CQL CQL CQL CQL CQL CQL FEE 1?" g $

y D r

o t

g e

a C O

. C B

e l

v a A X X X X X X V

3 4 3 4 3 4 m3aag0 - - - - - -

I I I I D D r

. e b

m 0 0 0 0 0 0 u

N 1 1 1 1 1 1 g 6 6 6 6 6 6 n 7 7 7 7 7 7 i S 5 5 5 5 5 w I 1 1 1 1 1 a - - - - - -

r C C C C C C D M M M M M M 1

em 0 B B B B B B T

I N

r U e -

b m E u R N I l

v e

B 1

P A

2 P

B 3

P 4

A P

B 6

P 7

A P

- UO G

M c

a V V V V V V V I I I I I I

n

. J o i

t 3 a -

l 3

. i . . . . . . 1 t c c c c c c .

n e e e e e e I e s s s s s s I V

3 3 3 3 3 3 e 5 5 $ 5 $ 5 g

r s e e e e e e u k m m m m m m P r i i i i i i a t t t t t t t u

- n c n n n e n n e 7 o o o o o i o

. m i i i i i n t t t t t t i a a a a a a a l l l l l l t o o o o o o n s s s s s s o I I I I I I C

m 3%Sa %

  • F F

F F

F F

e wSy3 R R R R R R t

_ s y ,

S a" ge X X X X X X

%gs T T T T T T T T T T T T U En1s" ge CQL CQL CQL CQL CQL CQL

- y D r

- o g

e C t

e C

B e

l v

a A X X X X X X V

1 2 1 2 3 4 1 1 1 1

=38Ogo - - - - - -

C C G G F F r

e b

m 0 0 0 0 0 0 u

N 1 1 1 1 1 1 g 6 6 6 6 6 6 n 7 7 7 7 7 7 i 5 5 5 5 5 5 w 1 1 1 1 1 1 a - - - - - -

r C C C C C C D M M M M M M

.gu B B B B B B I T

I N

r U e -

b m E u R

- N A B A B I B A' 0 1 2 3 U e 8 9 1 1 1_ 1 G

v - - - - - -

c l P P P P P P M a V V V V V V V I I I I I I

n i

t l

o a

4 3

1

- O i .

t c c c c c c .

n e e e e e e 1 e s s s s s s 1 V 3 3 3 3 3 3 e 5 5 5 5 5 5 g

r s e e e e e e u k m m m m m m P r i i i i i i a t t t t t t t m n e n n n n n n e R o o o o o o i i i m i i i t t n t t t t a

i a a a a a a l l l l l l o

t o o o o o n s s s s s s o I I I I I I C

  1. 2EUU# * * * * *
  • m EU $" F F F F F F e R R R R R R t

s S

y m" $E* X X X X X X w 3Y*

T T T T T T T T T T T T CQL CQL CQL CQL CQL CQL 35Sa?a uE" y

r D_

o t

C g

e a .l C

O B

e l

v a A X X X X X X V

1 2 1 2 1 2 1 1 1 1 1 1

" M53 o E E

D D

C C

r e

b m 0 0 0 0 0 0 u

N 1 1 1 1 1 1 g 6 6 6 6 6 6 n

7 7 7 7 7 7 i 5 5 5 5 5 5 w 1 1 1 1 1 1 a - - - - - -

r C C C C C C D  !

? M M M  !

! M 1

mEU B B B B B B

_ T I

N r U e -

b m E u

N A B A B A B l

v e

5 1

P 6

1 P

7 1

P 8

1 P

9 1

P 0

2 P

- R6 G

M c

a V V V V V V Y I I I I I I

s MC-1576-1.0

VALVES
IVP-1B, IVP-2A, IVP-3B, IVP-4A, IVP-6B, IVP-7A, IVP-8B,

{ IVP-9A, IVP-10A, IVP-11B, IVP-12A, IVP-13B, IVP-15A, d

IVP-16B, IVP-17A, IVP-18B, IVP-19A, IVP-20B 4

CATEGORY: A CLASS: B

]

j FUNCTION: Provide containment isolation.

1

! TEST REQUIREMENT: Cycle and time valves every three months.

BASIS FOR RELIEF: Technical Specification 4.6.3.4 requires a leak rate test 1

on these valves whenever they are cycled. In addition, q

Technical Specification 4.6.1.9 places severe restrictions on the operational time and alignment permitted for this i{ system during normal operation. IVP-1, IVP-2, IVP-3, and 17P-4 may be opened for only 90 hours0.00104 days <br />0.025 hours <br />1.488095e-4 weeks <br />3.4245e-5 months <br /> a year at power.

4 The rest of the VP valves may not be opened st all during power operation.

) , ALTERNATE TESTING: Valves will be timed whenever the system is operated or l whenever the valves are cycled, and the elapsed time since j the previous test has been three months or greater, j

I i

I 1

1 O

McGUIRE - UNIT 1 II.13-5 Revision 4 1

0

- - - - - - _ _ . _ - . - , a 7, -.,... n. , ,.

I 6

l I

l SYSTEM: CONTAINMENT SPRAY f

, FLOW DIAGRAMS: MC-1563-1.0 l  :

i 1

! l l

! I i

i i

P l

L i

I 4

1 a

i J

l f

I i

I i

i.

s t

J l

3 McGUIRE - UNIT 1 II.14-1 I

i 1 _ _ _ _ . . , _

l 4

y a 2 r -

e e e r p e e e 4 i S m m m m m m 1 v

i i i t

i t

i t

i t I e

t t t R n e e e 1

e e e e l m l l l l l n c c c c c c i y y y y y y a s c c c c c c t k n r . . . . .

x o a x x x x x C m a a a a a a e m m m m m m R . . . .

c m c c c c c e

e e e e e e t s s s s s s s

y 0 0 0 0 0 0 S 1 1 3 3 1 1

$wy8B% w3y$ F F F F R R R R

,$8?*%d$ X X X X myE82E* y$ T T T T T T T T T T C M C M C C M C C M y D r

o g

e C X X X X t

a C

B X X X X X X e

l v

a A V

3 3 2 mBE4gO 5 3 5 3 1 1 1 4 4 2 K K J J G F F 1 1 F F r

e b 0 m 0 0 0 0 0 0 0 0 0 u 1 N 1 1 - 1 1 1 1 1 1 1

- - 3 - - - - - - -

g 3 3 4 3 3 3 3 3 3 3 n 6 6 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D  !

? H M M M M M M M M mm U B B B B B B B B B B 1 T

I

_ N r

e _ U b -

m u E N A B A A A A R 3 6 8 1 8 0 1 2 9 0 e 4 4 3 4 1 2 2 3 2 3 v - - - - - - - - - - C l S S S S S S S S S S c a N N N N N N N N N N M V I I I I I I I I I I l

4

! l  ! , , ; , l 4 _

/ y n _

a 3 o .

r - i p e e e e 4 s S m m m m 1 i _

i i i i . v t t t t t 1 e _

n 1 R _

e e e e e -

m l l l l n c y

c y

c c i y y _

a s c c c c t k n r . . . .

o a x x x x .

C m a a a a _

e m m m m _

R c c c m c .

e e e e e t s s s s _

s ,

y 0 0 0 0 -

S 3 3 1 1

$YEag ?YE F F F F _

R R R R Oa?A ~3Y* X X X X ,

T T T T T T T T _

0"!a? & 24 E" M N C C C M C M _

y D ,

r ,

o g

e C X X X X t

a _

C B X X X X -

e v ,

l a A V

2 3 3 _

2 1 1 1 4 2 4 2 _

%B28" 1 1

B B

C D

D C

B r

e ,

b m 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 n 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M M M M M H M M _

$3U B B B B B B B B 1 T

I .

N r U _

e b - ,

m u F.

N B B D 3 B B S 6 2 3 I e 3 4 3 1 I 1 1 1 U v - - - - - - - - G c

l S S S S S S S S ,

a N N N N N N N N M _

V I I I I I I I I _

4 4 4 4 4

! ,I1 <!! I

MC-1563-1.0 VALVE: INS-30, INS-33, INS-16, INS-13, INS-46, INS-41 CATEGORY: C CLASS: B FUNCTION: Open on flow from the Containment Spray Pumps.

TEST REQUIREMENT. Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design has not provided a means for verifying that the valve opens when flow is initiated for the NS pumps.

4 ALTERNATE TESTING: These valves will be tested during refueling outages by disassembly.

O O

McGUIRE - UNIT 1 II I4-4 Revision 4

. _ - . . _ . . _ .- . .. = _

f MC-1563-1.0 i

i VALVE: INS-21, INS '. <

CATEGORY: C [

CLASS: B '

FUNCTION: Prevent flow path from the Containment Recirculation i Sump to the FWST.  !

TEST REQUIREMENT: Verify proper valve movement once per three months.  !

BASIS FOR RELIEF: Full stroke exercising with flow would require spraying l the reactor building.

4 ALTERNATE TESTING: Valves will be full stroked at refueling by disassembly.

Valves will be partial stroked quarterly. j ,

i 1 i 6

i l

f i

t 5

i i

i i

i McGUIRE - UNIT 1 II.14-5 4

Revision 4

1 I

SYSTEM: CONTAINMENT VENTILATION COOLING WATER

! FLOW DIAGRAMS: MC-1604-3.0 l

4 1

I i

i 4

i i

i i

i l

a l

I f

1 1

I 1

j 1 I

McGUIRE - UNIT 1 II.15-1 1

1

. - - . _ - _ , _ , _ , , . . , , ._ I

" System: Containment Ventilation

@ Cooling Water 0

a #

%  ? m 2

5 a E8

$ 2 Valve Category u 3E 2U M

o u 8

H

$ m E~

Ed Hd Valve Number Drawing Number A B C D Remarks IRV-79A B MC-1604-3.0 K-7 X CT RF* Isolation time $30 sec.

LT 1RV-80B B MC-1604-3.0 K-5 X CT RF* Isolation time $30 sec.

LT 4 l 1RV-32A B MC-1604-3.0 K-10 X CT X CS Isolation time 560 sec. l LT RF*

4 l 1RV-33B B MC-1604-3.0 K-12 X CT X CS Isolation time 560 sec.

LT RF* l 1RV-130A B MC-1604-3.0 J-12 X X MT X RF*

LT 4 l 1RV-77B B MC-1604-3.0 C-10 X CT X CS Isolation time 560 sec.

LT RF* l 4 l 1RV-76A MC-1604-3.0 C-12 X B X CT CS Isolation time $30 sec. l LT RF*

Mc E - UNIT I I1.15-2 Revis 4

t ,  ! i i i 0b n o . .

3 5

i c c 1 t e e .

a s s 1 l 1

. i 0 0 t 3 n

e

< 3-Vr s e e k m m

- t e. r i i na a t t eW m m e n n ng R o o i n i i ai t t tl a a no l l oo o o CC s s I I m

e 1 t

s iUe6$N F R

S y maUE X

hEi# uOY#

TT TT TT 0lEaEm uE ML CL CL y D r

o g

e C X t

a C

B e

v l

a A Z X X V

2 1 7 5 ENcY oO B C C r

e b

m 0 0 0 u

. N 3 3 3 g 4 4 4 n 0 0 0 i 6 6 6 w 1 1 1 a - - -

r C C C D M M M B B B 1 mEU T I

N r U e

b -

m u B A E

. N 6 2 1 R

~ 2 0 0 I e 1 1 1 U f( v - - - G c

l V V V a R R R M V 1 _

1 1 s i I iiI ' ," 1 4 4 e l :

i l

MC-1604-3.0 O

VALVE: IRV-77B, IRV-76A, IRV-32A, IRV-33B CATEGORY: A CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Cycle and time valve once per quarter.

BASIS FOR RELIEF: Failure of one of these valves in the closed position would inhibit cooling flow to the containment. This would result in a steep rise in lower containment 4 temperature which could exceed tech. spec. limits and cause a plant shutdowm.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

. O-l 1

l l O

~

McGUIRE - UNIT 1 Revision 4 l

l 4

MC-1604-3.0 1

i VALVE: 1RV-130, IRV-126 CATEGORY: A, C i CLASS: B i FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indications for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.

I 1

I j McGUIRE - UNIT 1 II.15-5 i

- . _ . . , _ _ , _ _ _ _ . , . . _ . - , _ , . , _ , . , . - - ,, - , ~ . . - - .

SYSTEM: CONTROL AREA CHILLED WATER FLOW DIAGRAMS: MC-1618-1 I

i i

l

(

)

\

l O

l l

McGUIRE - UNIT 1 II.16-1

l l l 4

r e 2 t

a -

W e e e e e e 6 s i

m m m m m m 1

.ve d i i i i i i e t t t t t t I I R l

l e e e e e e i l l l l l l h c c c c c c C y y y y y y s c c c c c c a k e r , . . .

x x

r a x x x x A m a a a a a a e m m m m m m l R o . . . . . .

r c c c e

c e

c e e c

t e e n s s s s s s o

C 0 0 0 0 0 0 4 6 4 4 4 4 m

e t

s #2aUM S

y SUE O ?e ~0Y T T T T T T T T T T 0E!d?a uE C M M C C C M M C C y D r

o g

e C X X X X t

a C

B X X X X X X e

l v

a A V

0 2 2 0 2 4 2 9 1 1 1 2 9 1 1 1 a%SE o 1 1

K K

J H

F C

C D

E

_ r e

b m

u N 1 1 1 1 1 1 1 1 1 1 g 8 8 8 8 8 8 8 8 8 8 n 1 1 1 1 1 1 1 1 1 1 i 6 6 6 6 6 6 6 6 6 6 1 1 1

_ w 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M M C C C C C C C C C C 1

_ T

_ I

_ N U

r e

b -

m E u R N A B B B B I

A 3 4 6 7 3 4 5 9 7 e 2 1 1 1 1 8 9 9 9 2 U v - - - - - - - - - - G l C C C C C C C C C C c a Y Y Y Y Y Y Y Y Y Y M V 1 1 1 1 1 1 1 1 1 1 l l l l l l 4 4 4 4 4 4

l l l l l r 4 -

- e n t

a 3oi W e e e e e 6s m m m m m 1i d i i i i i .v e t t t t t I e l

- l e e e e e IR i l l l l l h c y

c y

c y

c y

c C y

- a k s c c c c c e r . . . . .

r a x x x x x A m a a a a a e m m m m m l

t o

r R

c e

c e

c e

c e

c e

- n s s s s s o

- C 0 0 0 0 0

. 6 6 4 6 4

. m s e etlah

._ t  ?

s y !U$

S

- a :aa dA#

T T T T T

- Oc!a?a a5 C C C C C y D r

o

- g e C .

t a

C B X X X X X e

l v

a A V

4 2 2 2 2 1 1 1 1 1

  1. S2 o F G

_ F E E r

e b

m u

N 1 1 1 1 1 g 8 8 8 8 8 n

-. 1 1 1 1 1 i 6 6 6 6 6

. w 1 1 1 1 1 a - - - - -

r C C C C C D M M M M M

A C C C C C I T

I

. N r U e

b -

m u E

/ N A A B A B R 0 9 9 8 0 I

% e 3 2 3 3 4 U v - - - - - G l C C C C C c a M Y Y Y Y Y .

V 1 1 1 1 1 _

l l l l l 4 4 4 4 4

, j

.l SYSTEM: DIESEL GENERATOR ENGINE FUEL OIL FLOW DIAGRAMS: MC-1609-3.0 MC-1609-3.1 i

+

McGUIRE - UNIT 1 11.17-1 l

l i

O l

e u

2 7

1

- 9 F 1 e 1 n

i g

n E s k

r r o a _

t m a e r R e

n e

G l

e s

e i

D 8UaUM#

m EU E" e

t s

m" $E*

y ~ 3 Y*

S T f 0$8a?a u$H M f f

_ y D r

o C

g e

t a

C X X 9

B e

v l

a A V

3 3 1 1

%S38o E E r

e b

m 0 1 u .

N 3 3 g 9 9 n 0 0 i 6 6 w 1 1

- a - -

- r C C D M M 1

EM C C T

I

_ N r U e -

_ b m E u R N 4 I l

e v

a 2

9 D

F 0

1 D

F

- 4e M

c V I 1

SYSTEM: DIESEL GENERATOR ROOM SUMP PUMP f

l FLOW DIAGRAMS: MC-1609-7.0 I

i f

I l

i l

l l

i l

l l

l 11.18-1 f McGUIRE - UNIT 1 Revision 4

f p

m u

P 2

p - i m 8 s u 1

.i S v I e m IR o

o R

r s o k t t t r u u a a h h r m s s e e n R d d e e e G i i f f l i i e r r s e e e V V i

D m e3ME3N e wSN$

t s r y * :E$

S

%d$

T T T T T T m UE01l* N$ M M M M M M y D r

o g

e C X X X X X X t

a C

B e

v l

a A V

1 1 1 1 1 1 1 1 1 1 1 1 m3$a oO L K J F E D r

e b

m 0 0 0 0 0 0 u

N 7 7 7 7 7 7 g 9 9 9 9 9 9

_ n 0 0 0 0 0 0 i 6 6 6 6 6 6 w 1 1 1 1 1 1 a - - - - - -

r C C C C C C

_ D M M M M M M _

_ 1 C C C C C C

=$U T I

_ N

_ r U e -

b m E u R N I 1 3 5 U e 3 5 7 1 1 1 G

l v - - - - - - c a W W W W W W M V I I I I 1 I 4

d

)

i i SYSTEM: DIESEL GENERATOR STARTING AIR i

i FLOW DIAGRAMS: HC-1609-4.0 i i l

  • l I

I i 4

i 4

I l

i l

l l

i l

l  !!cGUIRE - UNIT 1 II,19 1 l l

.Il lI1 l ll r

O i

A .

2 g -

n 9 1

i t

r 1 a 1 t

S r

o s t

a k

r r a e m n e e R

- G l

e s

e i

D e3%S3N

wSg$

m e

t s ,

y n:g$

S X X X X X X X X Tj$ _

T T T T T T T T 0 EB1?* g$ C C C C C C C C y D r

o t

C g

e a

C O

B X X X X X X X X e

v I l

a A V

2 2 2 2 2 2 2 2 384gO K K I K E F C C r

e b

m 0 0 0 0 0 0 0 u J.

N 4 4 4 4 4 4 4 4 g 9 9 9 9 9 9 9 9 n 0 0 0 0 0 0 0 0 i 6 6 5 6 6 6 6 " 6 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M M M M M M M M 1

.m U C C C C C C C C T

I N

r U e -

b m E u R N I 2 1 4 3 5 6 8 7 l

e v

6 G

6 G

6 G

6 G

6 G

6 G

6 G

6 G

- UO G

M c

V a V I

V I

V I

V I

V I

V I - V I

V I

,l lllI lll l 1ll l l ll l'e

Q MC-1609-4.0 V

VALVE: IVG-61, IVG-62, IVG-63, IVG-64, IVG-65, IVG-66, IVG-67, IVG-68 CATEGORY: B CLASS: C FUNCTION: Starting air solenoid control valves.

TEST REQUIREMENT: Verify valve operability every three months.

BASIS FOR RELIEF: This valve is automatically opened when the diesel generator engine is started. The valve will then close after the engine is started. Failure of this valve to j perform its required function should be indicated by the i diesel's performance when it is periodically tested (once I per 31 days). Direct observation of valve movement is impossible.

ALTERNATE TESTING: Valves will be considered to be functioning properly if l the diesel's starting time is within tech spec. limits.

O

)

l l

l i

l l

O McGUIRE - UNIT 1 II.19-3

i

{

SYSTEM: EQUIPMENT DECONTAMINATION FLOW DIAGRAMS: HC-1568-1.0 l

l l

t 1

1 a

i 1

1 j

i l

}

s 1

I i

i l

1 i

}

i I

1 i

McGUIRE - UNIT 1 II.20-1

. - - -..,,._n. _ - . - . - . - - , . , , - , , - , , , - - . - , , , , , , . , - , , ,

n -

o -

i t 2 a -

i n 0 s i

m 2. vi 1

a 1 e t R n

o c

e D s k

t r n a e m m e _

p R _

i e e u

q v v i i E s s s s a a

P P m

e t

s e3unged *

  • y c F F S ocY$ R R

- i s

, $ E" M u0Y#

T T L L myEE1eem uE

_ y D r

o g

e C X t

a C

B e

l v

a A X X V

8 9 mBeawEO" E E r

e b 0 m 0 u 1 N 1 g 8 8 n 6 6

- i 5 5 1

w -

1 a C r C D M M B B 1 EM" T I

_ N r U e -

b m E u R N

3 3 e 1 2 G

v - -

c l E E a W W M V I I 4

I

(

I SYSTEM: FEEDWATER FLOW DIAGRAMS: MC-1591-1.1 l I

k i

T 1

i i

4

}

i i

.i 4 ,

\

l i

1 i

}

l .

i i

! l i

J. <

i 1

I l

McGUIRE - UNIT I II.21-1

e m w u u n

System: Feedwater c m v u cu G m o e o e u a u e w e -<

u o M

o <

d &

c e co w e w w

c m v e m u Valve Category u w u e o m a m e.4 o e 0 0 Valve Number Drawing Number A B C D Remarks ICF-26 B MC-1591-1.1 11 - 3 X CT X CS Isolation time 5 5 sec.

Q ICF-28 B MC-1591-1.1 II-6 X CT X CS Isolation time $ 5 sec.

Q ICF-30 B HC-1591-1.1 11 - 9 X CT X CS Icolation tispe 5 5 sec.

Q 1CF-35 B MC-1591-1.1 11-13 X CT X CS Isolation time 1 5 sec.

Q f

<- - l 1CF-129 B MC-1591-1.1 11 - 3 X - CT X CS Isolation time $-10 sec. -

Q; f ,/ i

.-- ;L ,  : '_

.- , ~ , .

4 ICF-137 D HC-1591-1.1 11 - 3 X

- CT -

Isolation time <- 10 sec.

q

,. , , , - . ,i ,

ICF-128 B_ HC-1591-l'1 ,,11-6 X , CT , X CS Isolation time $ 10 sec.

g,- , q- ,

-  ?

l .' (

\ ,

l ,

, y

- s II.21 '

((, -

./ s' ,

j

- . 1

/

7.

4

. j) % *. .,

' /

f - 3 o n

. . . . . - i c c c c c . . 1 s

- e e e e e c c

2. vi

~

(., s s s s s e e _

' s s I e _

, i 0 0 0 0 0 I R _

'r 1 1 1 1 1 5 5

, < e _

t a

5 5 5 5 $ 5 5 _

,' w s e e e e e e e d k m m m m m m m e r i i i i i i i

, e a t t t t t t t

- F m e n n n n n n n R o o o o o i

o o i i i i i i m t t t t t t t e a a a a a a a t l l l l l l l

  • . sy o o o o o o o s s s s s s s S I I I I I I I 1

,>Ye835 enUM S C

S C

S C

S C

. - M$8l* MOM X X X X

' f , , . T T T T T T T 0c881?a uM CQ CQ CQ CQ CQ CQ CQ y D
g. ,

r o

!,/.q g e C t

-. a

. , ' s.. .

C B X X X X X X X e

v l

a A V

0 0 3 3 3 6 1 1 1 1 1 9

a. 3am?.O I I

1 1 H H H K K r

e b

m 1 1 1 1 1 1 1 u . . . . . . .

. N 1 1 1 1 1 1 1 g 1 1 1 1 1 1 1 n 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 a - - - - - - -

r C C C C C C C D H H H M M H M B B B B B B B 1 Ee T

I N

r U e

b -

m u E N 6 7 5 6 4 4 5 R r l e

v 3

1 F

2 1

F 3

1 F

2 1

F 3

1 F

0 1

F 0

1 F

I U

G c

a C C C C C C C M V 1 _ I 1 I 1 I 1 4 4 4 4 4

0 U System: Feedwater S 0 E S  : 0 a  ? d#

M  ? a 3 & ~ E E E Valve Category a 0 Y d 8 E U E

Valve Number Drawing Number A B C D Remarks 4l ICF-106 B MC-1591-1.1 K-5 X CT Q

X CS Isolation time 5 5 sec.

K-2 4l ICF-107 B MC-1591-1.1 X CT Q

X CS Isolation time 5 5 sec. l G-12 4l ICF-151 B MC-1591-1.1 X CT Q

10 sec. max. operating time l

4l ICF-153 B MC-1591-1.1 G-11 X CT Q

10 sec. max. operating time l

4l ICF-155 B MC-1591-1.1 G-11 X Q

CT 10 sec. max. operating time l

MC-1591-1.1 C-12 4l ICF-157 B X Q

CT 10 sec. max. operating time l

ICF-17 B MC-1591-1.1 K-3 X CT X CS 5 sec. max. operating time Q

McGUIRE - UNIT 1 II.21-4 Revision 4 O O O

e e e m m m 5 i i i -

t t t 1 2

. g g g n n n 1

- r e

i t

a i

t a

i t

a 1

t r r r

- a e e e w s p p p d k o o o e r e a . . .

F m x x x e a a a R m m m m . . .

e c c c t e e e

_ s s s s y

S 5 5 S

_ EYEEd# ?YEH S C

S S C C 3Eaa 3 e" X X X l

T T T CQ CQ CQ 3lea?& uEH y D

. r o

O t C

g e

a C

B X X X e

v l

a A V

3 6 9 1

. E#22Eu - - -

X K K r

e b

m 1 1 1 u . . .

N 1 1 1 g 1 1 1 n 9 9 9 i 5 5 5 w 1 1 1 a - - -

r C C C D M M M I

B B B 1 EOU T

I N

r U

. e b -

. m u E N R 0 3 2 I e 2 2 3 U v - - - G l

a F

C F

C F

C M c

V I I I

MC-1591-1.1 ,

I l

l VALVE: ICF-26, ICF-28, ICF-30, ICF-35 CATEGORY: B l CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve once per quarter.

BASIS FOR RELIEF: Closure would isolate the Steam Generator feedwater which could result in a severe transient in the Steam Generator which could result in a Unit trip.

ALTERNATE TESTING: Valve will be cycled and timed during told shutdowns.

l O

l

[

l O

l McGUIRE - UNIT 1 11,21 6

J j

l j MC-1591-1.1 l

i

! VALVE: ICF-20, ICF-17, ICF-23, ICF-32 1

a j CATEGORY: B i

! CLASS: F j  !

l FUNCTION: Feedwater control.

) TEST REQUIREMENT: Cycle and time valve once per quarter.

i

! BASIS FOR RELIEF: Closure would isolate the steam generator feedwater which  ;

j could result in a severe transiet in the steam generator 1 which could result in a unit trip.

1 ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

1 i

i i

i 4

l l

i i

i i

i 1

4 I

i i

i 1

McGUIRE - UNIT 1 II.21-7 a

i

l l

l MC-1591-1.1 i O

VALVE: ICF-129, ICF-128, ICF-127, ICF-126 CATEGORY: B CLASS: B FUNCTION: Opens to provide startup feedwater supply to the steam generators.

TEST REQUIREMENT: Cycle and time valve once per three months.

BASIS FOR RELIEF: Cycling valve during power operation could induce unwanted transients in steam generators. This would result in an increase in flow to the main feedwater 4

nozzles causing vibrations in the preheater section of the steam generators.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

O i

l l

l l

l l

O II'2I" McGUIRE - UNIT 1 Revision 4

l

I 1

i i MC-1591-1.1

! I i

j VALVE: ICF-104, ICF-105, ICF-106, ICF-107 CATEGORY: B CLASS: B j

i FUNCTION: Provides tempering flow to steam generators.

TEST REQUIREMENT: Cycle and time valve quarterly.

i j BASIS FOR RELIEF: Cycling this valve during operation could result in loss i of S/G level control and result in a plant trip.

ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

I l

1 i

i 1

1 1

1 i

1 i

l 1

l I i l

i

)

J l

4 k

f 1

McGUIRE - UNIT 1 11.21-9 f

,m - . .. . . . , - _ . - . , - , , - , _ , , - - s.... , .

! SYSTEM: FIRE PROTECTION f FLOW DIAGRAMS: MC-1599-2.2 l

< l 1

l l

l l

l 1

McGUIRE - UNIT 1 II.22-1

n o

i.

t 2

2 2

- e c I e I t

o r

P s

e k r r i a F m e

R

e m v e i t s s s y a S P g

F F 0>Ue65* ?UMCH R R 1

X _

M$ aa ~OMG" ._

T T T

" cE$? & uMOH L MQL y D r

o g t t

C e

a C X O

B e

v l

a A X X V

5 7 _

E E

%23OO r

e b

m 2 2 u

N 2 2 g 9 9 n 9 9 i 5 5 w 1 1 a - -

r C C D M M B D 1 EeHo T

I N

r U e

b -

m u E N 1 3 R 2 2 I l

e v

a 8

F R

8 F

R

. UO C

M c

V I 1 _

l

MC-1599-2.2 f

l VALVE: 1RF-823 1

{ CATEGORY: A, C i

I CLASS: B j FL.?; TION: Prcvide containment isolation.

t TEST REQUIREMENT: Verify proper valve movement once per three months.  :

1 i EASIS FOR RELIEF: The system design does not provide any indication for j verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified shut by leak rate test performed in accordance with Appendix J.

s t

l l

l i

N i.

i i

I i

k i

i i

i i

i 3

t 1

1 i

i I

5 l McGUIRE - UNIT 1 II.22-3 t

, , . . _ _ , _ _ _ . _ . _ , . , _ _ _ , _ _ - . _ , _ . . . - _ . . . ~ , _ , . . .__.. .. .. _ _ ,____.._ , _ , . . . . , _ _ . . . , , . . - - _ ,

1 1

1 l

, SYSTEM: ICE CONDENSER REFRIGERATION l FLOW DIAGRAM 3: MC-1558-4.0 l i

j 5 '

i' 1 l

l I ,

l 4

A i

8 i

i j ..

4 i

i l

i I l T

l i

l t

i McGUIRE - UNIT 1 II.23-1

n o

i t 2 a . . . - i r c c c 3s e

g e

s e

s e

s .

2. vi i I e r 5 5 5 I R f 1 1 1 e

R 5 5 i t s e e e e k m m m s r i i i n a t t t e m d e n n n n R o o o o i i i C t t t a a a e l l l c o o o I s s s I I I m

e e3#E3N * * *

  • t F F F F s wSg$ R R R R y

S

, $ $ E" tj$ X T T T T T T T T CQL CQL CQL MQL fE01s" g$

y D r

o g

e C t X a

C E

e v <

l a A X X X X V

2 3 3 3 1 1 1 1 m32agO K K K F r

e b

m 0 0 0 0 u

N 4 4 4 4 g 8 8 8 8 n 5 5 5 5 i 5 5 5 5 w 1 1 1 1 a - - - -

r C C C C D M M M H mgU B B B B 1 T

I N

r U e -

b m E u B' A A N 3 4 8 9 R 3 3 2 2 I e 2 2 2 2 U v - - - - G l F F F F c a N N N N M V I I I I 4

1 .

1

MC-1558-4.0 J

VALVE: INF-229 i

CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.

i

/-

i s

l l

1 l

I 1

McGUIRE - UNIT 1 II.23-3 1

I 1

SYSTEM: INSTRUMEET AIR FLOW DIAGRAMS: MC-1605-1.2 ,

l MC-1605-1.3 1

i t

l l

i i

l McGUIRE - UNIT 1 II.24-1

r .

2 4

O i . . c 2 A c c e e e s I t s s I n 5 e 5 5 1 m 1 1 $

u r s e e e t k m m m s r i i i n a t t t I m e n n n R o o o

i i i m t t t e a a a t l l l s o o o y s s s S I I I

$dE$dd ?U$ F R

F R

F R

F R

F R

E$?a ~dY# X X T T T T T T T T T T 0E03?a uE" CQL CQL 1 t QL 1 QL 1

CQL y D r

o g

e C X X t

a C

B e

l v

a A X X X X X V

1 2 3 4 5 1 m3a4 oO C E

B E

J r

e b

m 2 2 2 2 3 u

N 1 1 1 1 1 g 5 5 5 5 5 n 0 0 0 0 0 i 6 6 6 6 6 w 1 1 1 1 1 a - - - - -

r C C C C c D  !

?

t

?

?

i t

B B B B B 1 mEU T

I N

r U e

b -

m u B B B .

N 0 8 4 9 9 5 4 2 4 2 e 1 1 1 1 1 v - - - - - C

, l I I I I I c a V V V V V i t

V I I I I I 4 4

,ll

O i r

c c

3 4

2 A e e s s 1 t 1 n 5 5 e 1 1 m $ $

u r s e e t k m m

s. r i i t a t t I m

_ e n n R o o

i i m t t e a a t l l s o o y s s S I I

$YE 4* ?U$H F F F F R R R R 0:ae ~3Y# X X 05!a?& uEH T T T T T T TT MOL r. Q L MQL LCQ y D r

o O C g

e t

a C X X 7, B e

l v

a A X X X X V

3 1 3 1 1 1 4

%RI8 J D D D r

e b

m 3 3 3 3 u

N 1 1 1 1 g 5 5 5 5 n 0 0 0 0 i 6 6 6 6 w 1 1 1 1 a - - - -

r C C C C D M M M M B B B B EM 1

_ T I

N r U e

_ b -

_. m u B E N 0 2 R O

_ 1 0 6 6 6 I e 4 1 1 3 U v - - - - G l I I I I c a V _ VI V V M V I _ I I

< ' 'i ,  ; t  ! l  ; .

I I

MC-1605-1.2 O

VALVE: IVI-124, IVI-149 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

1 ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

9 O

McGUIRE - UNIT 1 II.24-4

l l

l l

l MC-1605-1.3

! VALVE: IVI-40, IVI-161 l

l CATEGORY: A, C i  !

LLASS: B FUNCTION: Provide containment isolation. l l

TEST REQUIREMENT: Verify proper valve movement once per three months.

! BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

4 P

l i

4 l

I McCUIRE - UNIT 1 II.24-5

..__-._---,m--,- - - - - , .-.- . .--.-4 % -. , , , , - - - - , . - , ,. , . _ . -

1 i

i i

SYSTEM: LIQUID WASTE RECYCLE 1

i FLOW DIAGRAMS: MC-1565-1.0 MC-1565-1.1 MC-1565-7.0 f

1 h

i i

i l

1 i

I I

l l

I i

i i

1 j

4 4

i i

?

1 1

4 i

i; d

1 i

k i

McGUIRE - UNIT 1 II.25-1 i

i 4

--. r --- ..m.. - ,., - , m . , - - , - . , . . , - + , - , ,

e _

l c 2 .

y c -

e . . . . 5 R c c c c 2 e e e e e s s s s 1 1

t s 5 5 0 0 1

a 1 1 1 W $ $ $ $

d s e e e e i k m m m m u r i i i i t

q a t t t

_ i m n n L e n n o R o o o i i e i i

t t v t a

t a

m a a i e l l s l l t o o s o o.

s s s a s s y I I P I I S

F F F F P F

$wg634 wdg$ R R R R R R X

gN8?*$g5 T T T T T T T T T T T mgEE1i# g0 CQL CQL L l t QL CQL CQL y D r

o g

e C X t

a C

B e

l v

a A X X X X X X V

4 l 3 3 5 2 1 l 1 m33Yg0 J K J. J L K r

e b

m 0 0 0 1 1 I u . . .

N 1 1 1 1 1 1 g 5 5 5 5 5 5 n 6 6 6 6 6 6 i 5 5 5 5 5 5 w 1 1 1 1 1 1 a - - - - - -

r C C C C C C D M M  !

t M 1 t

l f

mm Y B B B B B B 1 T

l I N

r U e

b -

m u E N A B 4 4 5 6 4 B A e 6 6 2 2 1 2 v - - - - -

L c

l L L L L L V

a W I

W I

W I

W I

W I

WI M

O O O 0 U System: Liquid Waste Recycle

$ 0 E S  : e

a  ? d

%  ? &

3 & ~  ?

E 3 Valve Category u 0 U d

o 8

U E

Valve Number Drawing Number A B C D Remarks lWL-39A B MC-1565-1.1 J-5 X CT RF* Isolation time $10 sec.

Q LT IWL-41B B HC-1565-1.1 K-5 X CT RF* Isolation time $10 sec.

Q LT IWL-321A B MC-1565-7.0 H-7 X CT RF* 15 sec. max. operating time Q

LT 1WL-322B B HC-1565-7.0 I-6 X CT RF* 15 sec. max. operating time Q

LT IWL-385 B MC-1565-7.0 H-7 X X CT X RF*

Q LT McGUIRE - UNIT 1 II.25-3

MC-1565-1.1-VALVE: Ik'L-24 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

l O

l l

P O

McGUIRE - UNIT 1 II.25-4

. . . - . -- .- - . - .. .-. .. . ,=_

i

( MC-1565-7.0

l VALVE
1WL-385 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.  ;

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed m accordance with Appendix J.

i i

1 i

.j 4

i

.1 1

l McGUIRE - UNIT 1 II.25-5 i

. - - - - - . , ,,_.m. _ _ . . . , . . . .m__.-, ..,_,, . ., . - . . . . . . ... ,_.___ , , ,, , _ _ . . . , . . . _ . , . . , . , , . . , . , , . , , , _ . , , , , .

4 SYSTEM: MAIN STEAM FLOW DIAGRAMS: MC-1593-1.0 l

d f

i i

McGUIRE - UNIT 1 II.26-1 l

. Revision 4 l i

_ _ _ _ _ _ _ . . _ . . . - - - - - - - - - - - ' * ~ " ~ ~~

l l l l l l l l 4

2 6 s c

c c

c c

c c

c

2. vi e e e e e e e e e I R

m s s s s s s s s I a

e 5 5 5 5 5 5 5 5 t < 5 5 5 s 5 5 5 S

s e e e e e e e e n k m m m m m m m m i r i i i i i i i i a a t t t t t t t t M m n n e n n n n n n R o o o o - o o o o

i i i i i i i i m t t t t t t t t e a a a a a a a a t l l l l l l l l s o o o o o o o o y s s s s s s s s S I I I I I I I I

$I I c0 # E G S C

S C

S C

S C

S C

S C

S C

S C

O a e ~ y G" X X X X X X X X 3"! ?e gGH T T T T T T T T C C C C C C C C y D r

o g

e C t

a C

B X X X X X X X X e

l v

a A V

3 3 3 3 3 3 3 3 1 1 1 1 1 1 1 1

%3}OV K J 1 1 G F E C B r

e b

m 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 n 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M H M M M M M H B B B B B B B B 1

&o T

I N

r U e -

b -

m u B B B E N B B B A B A B A A A A 0 A 1 A 2 e 1 9 3 1 5 1 7 1 '

I v - - - - -

M M

M

- C l M M M  !

t M c a S S S S S S S S M V I 1 I I 1 I I 1 l l l l l l l l 4 4 4 4 4 4 4 4

1 i

MC-1593-1.0 VALVE: ISM-1AB, ISM-3AB, ISM-5AB, ISM-7AB, ISM-9AB, ISM-10AB, ISM-IIAB, ISM-12AB CATEGORY: B CLASS: B FUNCTION: Main Steam Isolation Valves.

TEST REQUIREMENT: C;rcle and Time Valves Quarterly.

BASIS FOR RELIEF: ISM-1, 3, 5, and 7, MSIV's, cannot be full stroke exercised during power operation since shutting an MSIV could result in a plant shutdown. Tech. Specs.

do not permit isolation of a steam generator. ISM-9 4

10, 11, and 12, MSIV Bypass valves, will be full stroke exercised quarterly. However, these valves cannot be timed at this frequency since this operation will be done utilizing a manual loader.

ALTERNATE TESTING: These valves will be partially stroked at least once per 92 days in accordance with PT/1/A/4250/01A (Main Steam Isolation Valve Movement Test). These valves will be full s stroked and timed at cold shutdown. ISM-9, ISM-le, 4 ISM-11, and ISM-12 will be full stroked quarterly and timed.

McGUIRE - UNIT 1 11.26-3 l

Revision 4

. ..= _ - .

i 1 ,

1-l i

SYSTEM: MAIN STEAM SUPPLY TO AUXILIARY EQUIPMENT / TURBINE EXHAUST FLOW DIAGRAMS: MC-1593-1.2 l

i 1 1 4 l 4 ,

l 4

4 1

i i

4 e

i j

l 1 ,

4 1

7 i

i 4

i

,1 1

4 4

i I

L i

( McGUIRE - UNIT 1 II.27-1 f

-- m___-________ w ---_ + - > , ,,-.*+-#-TF--e- e*9-%'- r -- rweggm**- V gmw--Nwwse-w we9w-w===w--p--wov v--sv-g y ee-e--+vy y7---w--- = - - -erMF-

y O

r at i s 2 l u -

i a e e 7 xh m m 2 ux i i .

AE

  • t t 1 1

ye e e l n l l pi c c pb y y ur s c c S u k T r . .

m/ a x x at m a a en e m m t e H S mp . .

c c ni e e i u s s a q l

f E 0 0 5 5 m

e e3NEey#

t s

y wSum H S

$m$$* YdoM l T

$"8 0 $ l# " eH C C y D r

o t

C g

e a

C O

B X X e

l v

a A V

5 2 m02$8ou F F r

e b

m 2 2 u

N 1 1 g 3 3

_ n 9 9 i 5 5

_ w 1 1

_ a - -

_ r C C D M f

f B B 1 maau

_ T I

N r U e

b -

m u B R E N A A R l

e v

8 4

A 9

4 A

- UO I

G c

a S S M V I I

SYSTEM: MAIN STEAM VENT TO ATMOSPHERE FLOW DIAGRAMS: MC-1593-1.0 l

i i

1 l

l 4

i I

I McGUIRE - UNIT 1 II.28-1

.._.-,---__,-._.,,,,,._,.,,..--.,._,c,-,,- ,_,nn _ ,,, ,-,_.,,,nn_. , m ne w ,n _ , n wm a- w

e r

h e

p s e$ e 2

8 2

- O o m i m

m i t I t t I

A e e

o l l c

t c y y

t s c c n k e r .

x V a x m a a m e m m a R e .

c t c S e e s s n

i 0 0 a 2 2 M

m o3%Eo N e wSy$

t s

y .

S n* g$

tj$

T P P P P P T P P P E EE1?* g $ C S S S S S C S S S

- y D r

o O

g e C X X X X X X X X t

a C

B X X e

v l

a A V

0 0 1 0 8 9 9 1 1 1 8 9 9 1 m38agO K J K J K K I 1 1 I l l

r e

b m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 3 3 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5

_ w 1 1 1 1 1 1 1 1 1 1

_ a - - - - - - - - - -

r C C C C C C C C C C D M M M M M H M M M M B B B B B B B B B B 1 egU T

I N

r U

_ e b -

_ m u

E N R 0 I l

v a

e 1 V

S 2

V S

3 V

S 4

V S

5 V

S 6

V S

7 V

S 8

V S

9 V

S 1

V S

- UO G

M c

V I I I I 1 I I I I I

l\

e r

Oh e p

s o

m i e

m 3

8 2

t t I A I e e o l m t c i y t t s c n k e e r . l V a x c y

m a m e m c a R e . .

t c c S e e s s n _

i 0 0 -

a 2 2 _

M

En@e" -

m EU $*F e .

t s

y S

OE?e ~3Y*

P P T P P P P P T P S S C S S S S S C S OE8a?& uE* E y D r

o g

e C X X X X X X X X t

a C  %

B X X e

l v

a A V

0 1 0 0 1 1 1 8 9 9 1 1 1 8 9 E%SE8o I I G F G F G G D C r

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 3 3 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M H H M M B B B B B B B B B B 1 Edo T

I N

r U e

b -

m u E N R O

1 2 3 4 5 6 7 8 9 0 I

_ e 1 1 1 1 1 1 1 1 1 2 U v - - - - - - - - - - G l V V V V V V V V V V c a S S S S S S S S S S M

_ V I I I I I I I I I I

l!'  ;'  ; i 4 i  !; , '

e r

h e

p s

o 4

8 2

- O m 1 t

A 1 o

t t s n k e r V a m

m e a R e

t .

S n

i a

M m s2a$d#

e t

s EU E" y

S 0$?8 ~O$#

P P P P S S S S

$U0a?& u$H y D r

o O

g _. _

e C X X X X _

t C

a _ _

1 1

e v

l a A V

0 0 1 9 1 1 1 E%420u - - - -

D C D D r

e b

m 0 0 0 0 u

N 1 1 1 1 g 3 3 3 3 n 9 9 9 9 i 5 5 5 5 w 1 1 1 1 a - - - -

r C C C C D M M M M

$$ B B B B 1 T

I N

r_ U e

b m

u E

_ N R 2 3 4 I UO

- 1 e

2 2 2 2 v - - - - G l V V V V c a S S S S M V I I I I

SYSTEM: MAKEUP DEMINERALIZED WATER FLOW DIAGRAMS: MC-1601-2.4 l

l l

I f

2 1

l McGUIRE - UNIT 1 II.29-1 l

l

r e

t a s 2 W di r 9 d o 2 e c z e I I

i s l

a 5 r 1 e

n s e i k m m r i e a t D m e n p R o u i e t k a a l l

f o s

I m

e y28$d#

t *

  • s F F S

y ?YEH R R O$?u ~3$# X TT TT CL ML 0ESa?e u$H y D

- r o

g e C X

_ t

- a C

_ B

_ e v

l a A X X

_ V

_ 1 1 1 1

$ %528" F D r

_ e

_ b

_ m 4 4 u

N 2 2 g 1 1 n 0 0 i 6 6 w 1 1

- a - -

r C C

_ D M H 0M B B 1 T

I N

r U e

b -

m u B E N 5 6 R 1 1 I e 1 1 U v i i

- G l t t c a Y Y M V 1 l

i i

i j MC-1601-2.4 1

) VALVE: n'M-116 ,

I

+

CATEGORY: A, C j CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

{ BASIS FOR RELIEF: The system design does not provide any indication for j verifying valve closure upon flow reversal.

I ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.  ;

1 i

i 1

i 1

1 3

i 1 .

i I

i I

1 McGUIRE - UNIT 1 II.29-3

l l

l SYSTEM: NUCLEAR SAMPLING i

FLOW DIAGRAMS: MC-1572-1.0 MC-1572-1.1 ,

MC-1572-3.0 i

1 .

i I I

[

4 i  !

4  !

4 i

i i

l i

i i

i i

1 1

Y I

1 i

I h i

I I i I

f McGUIRE - UNIT 1 II.30-1

4 g 2 n -

s i . . . . . 0 i i c c c c c 3 v p e e e e e e m s s s s s I R

a I S 5 5 5 5 5 1 1 1 1 1 r $ $ $ $ $

a e s e e e e e l k m m m m m c r i i i i i u a t t t t t N m e n n n n n R o o o o o

i i i i i m t t t t t e a a a a a t l l l l l s o o o o o y s s s s s S I I I I I E2@oU# F F F F F F R

R R R R R EU$

O:?E 0Y*

T T T T T T T T T T T 0E8a?a uEH CQL CQL CQL L CQL CQL y D _

r _

o <

g e L X t ~

a C _

B_

e _ _

l v

a A X X X X X X V

2 3 3 6 4 8 1 E%S28U 'K J K K K K r

e b

m 0 0 0 0 0 0 u

N 1 1 1 1 1 1 g 2 2 2 2 2 2 n 7 7 7 7 7 7 i 5 5 5 5 5 5 w 1 1 1 1 1 1 a - - - - - -

r C C C C C C D M M M M M M

$j B B B B B B 1 T

I r N U

e b -

m u E N B A R A A B 7 6 5 e 3 6 7 6 2 2 U v - - - - - - G l M M M M M M c a N N N N N N M V I I I I I I 4

,r~3 -))

Y). .

s' 0 Y System: Nuclear Sampling d 0 E O : 0 d  ? d

%  ? &

5 e ~  ?

E 2 Valve Category u O U M S Valve Number Drawii.g Number A B C' D Remarks INM-22A B  ?!C-1572-1.0 J-12 X CT RF* Isolation time 515 sec.

Q LT 4 1Nti-68 B 11C-1572-1.0 K-11 X X LT RF*

int!-72B B MC-1572-1.1 I-6 X CT RF* lsolation time $15 sec.

Q LT INti-75B B t1C-1572-1.1 I-8 X CT RF* Isolation time 115 sec.

Q LT IN?t-78B B tlc-1572-1.1 I-9 X CT RF* Isolation time 515 sec.

Q LT INti-81B B ffC-1572-1.1 1-11 X CT RF* Isolation time $15 sec.

Q LT 11.30-3 ficGUIRE - UNIT 1 Revision 4

i l

g n

c c

c c

c c

e p e e e e e e '

m s s s s s s '

a S 5 5 5 5 5 5 1 1 1 1 1 1 r 5 $ $ $ 1 5 a

e s e e e e e e l k m m m m m m c r i i i i i i u a t t t t t t N m _

e n n n n n n R o o o o o o

e i i i i i i m v t t t t t t e i a a a a a a t s l l l l l l s s o o o o o o y a s s s s s s S P I I I I I I f>U E O y ? U E* *
  • F F R R

$E?e ~MY*

4 T T T T T T T T 0ESn?& u$H L CQL CQ CQ C9 CQ CQ y D r

t C

o g

e a

B C X X X X X X e

e l

v a A X X V

9 9 1 2 2 5 6

%R?.8 G E K K I K K r

e b

m 1 1 0 0 0 0 0 u . .

N 1 1 3 3 3 3 3 g 2 2 2 2 2 2 2 n 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1

_ a - - - - - - -

r C C C C C C C

- D M M M M M M M B B B B B B B emu 1 T

I r N U

e b -

_ m

_ u A A B 8 B F.

N A 7 0 7 0 8

_ 1

_ 9 2 8 9 9 9 0 e 6 8 1 1 1 1 2 "

_ v - - - - - - - G l

t i M M t t M M M c a N N N N N N N M V I I I I I 1 I

Vg i n

5 0

l c c c c c c c 3 p e e e e e e e m s s s s s s s I a I S 5 5 5 5 5 5 5 1 1 1 1 1 1 1 r $ 1 1 1 $ 1 $

a c s e e e e e e e 1 k m m m m m m m c r i i i i i i i u a t t t t t t t N m e n n n n n n n R o o o o o o o

i i i i i i i m t t t t t t t e a a a a a a a t l l l l l l l s o o o o o o o y s s s s s s s S I I I I I I I

$UE0d* ?U$

O:?a ~y$

$EPua?& g$ T T T T T T T CQ CQ CQ CQ CQ CQ CQ y D r

o g

e C t

V C a

B X X X X X X X e

l v

a A V

1 2 2 6 8 9 9 1 1 1

%3}O 1 K K I K K I r

e b

m 0 0 0 0 0 0 0 u

N 3 3 3 3 3 3 3 g 2 2 2 2 2 2 2 n 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 a - - - - - - -

r C C C C C C C D M M H H M H H E U B B B B B B B I T

I r N U

e b -

m u A A A B B B A E N 1 7 0 1 7 0 1 R

0 0 1 1 1 2 2 I e 2 2 2 2 2 2 2 U v

( l a

M N

M N

M N

M N

M N

N M

M N

- C M

c V I I I I I I I _

ii  :!4l  ! i

, , 'i } ' '  ! j! , . I

i \

I SYSTEM: NUCLEAR SERVICE WATER i

FLOW DIAGRAMS: MC-1574-1.0 3 MC-1574-1.1

MC-2574-1.1 j MC-1574-2.0
MC-1574-2.1 MC-1574-3.0 j MC-1574-3.1 MC-1574-4.0 1

I 1

}

i i

i i

}

1 a

4

] :.

i i

i 1

i.

l i

I l

l

)

i

' l a

i 1

i' McGUIRE - UNIT 1 II.31-1 l

' l l

1

-_ _ - _ - _ - . - - . _ - - . - . . . . . . - - - . - _ _ . _ - - .. --. .. -. l

r W

t a

e e e e e e e e e e e 2

1 3

- O e m m m m m m m m m m i i i c i i i i i i t

i t t t t 1 i t t t t t vr e e e e e e e 1

e e e l e l l l l l l c

l c

l c

l c c S c c c c c y y y y y y y y y y r s c c c c c c c c c c a k e r , . . . . . . . . .

l a x x x x x x x a

x a

x a

x a

c m a a a a a a u e m m m m m m m m m m N R c

c c c c c c c c c

e e e e e e e e e e m s s s s s s s s s s e 0 0 0 t 0 0 0 0 0 0 0 s 6 6 6 6 6 6 6 6 6 6 y

S 0uy63% w4y

,$ 8 ?* t l; T T T T T T T T T T myE84?* y C C C C C C C C C C y D r

o C

g e

t a

C O

B X X X X X X X X X X e

l v

a A V ~

0 0 1 1 3 3 2 2 1 9 1 1 1 1 1 1 1 1 1 m32ag - - - - - - - - - -

J K K J 1 I F F E C r

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 4 4 4 4 4 4 4 4 4 4 n 7 7 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M mg C C C C C C C C C C 1 T

I N

r U e

b -

m C, C, E u

N A A A B A R l

e v

a A

7 N

R B

2 N

R A

3 N

R 3

1 N

R 2

1 N

R 4

1 N

R S

I N

R 4

A N

R 5

B N

R N

0 1

R I

U C

M c

O V I I I I I I I 1 I I

O i $

$ Y System: Nuclear Service Water e m e 8  % 8 -

m n 8 3 i

1 *

?  %

a l w m

e a Valve Category t 4 g g 3e g a o e e

Valve Number Drawing Number u A B C D H " " Remarks IRN-11B C MC-1574-1.0 F-11 X CT 60 sec. max. cycle time 1RN-1 C MC-1574-1.0 I-10 X CT 60 sec. max. cycle time IRN-301A,C C MC-1574-1.0 G-10 X CT 60 sec. max. cycle time

, IRN-302B C MC-1574-1.0 F-10 X CT 60 sec. max. cycle time IRN-98 C MC-1574-1.0 D-9 X CT 60 sec. max. cycle time

~

IRN-149A C MC-1574-1.0 J-7 X CT 60 sec. max. cycle time i

1RN-152B C MC-1574-1.0 E-7 X CT 60 sec. max. cycle time 1RN-150A C MC-1574-1.0 I-6 X CT 60 sec. max. cycle time 1RN-151B C MC-1574-1.0 F-6 X CT 60 sec. max. cycle time IRN-299A C MC-1574-1.0 K-2 X CT 60 sec. max. cycle time McGUIRE - UNIT 1 II.31-3

'V

- - - . . . * . , . . - , - - - . - - - , . . .-m.,,-,,- -s-,-.--- ..--- m oc. -- i + -, -4=--.

. --,,2-,,~.%.,.

. . - .-g ---

r.~ ,, - - . , , ~i-% v, . -- , -

r 4 e

t a 4 W e e e e e e e e e 1s i

e c i m

i m

i m

i m

i m i m

i m

i m

i m 3.i Ie v

i t t t t t t t t t IR v e e e e e r e e e e e l l l l l l c

l c

l c

l c

S c c c c c y y y y y y y y y r s c c c c c c c c c a k e r . . . . . . . .

x l a x x x x x x x a

x a

c m a a a a a a a u e m m m m m m m m m N R . . . . .

c c c c c c c c c

e e e e e e e e e m s s s s s s s s r e 0 0 t 0 0 0 0 0 0 0 s 6 6 6 6 6 6 6 6 6 y

S S S

$U $$ =* ?U$ C C X X 0$s& ~OU#

T T T T T T T T T 0" =?& u$ C C C C C C C C C y D r

o g

e C t

a C

B X X X X X X X X X e

v l

a A V

2 2 2 1 2 3 2 2 2

$%3 28" K I I I 1 1

1 1 G F F r

e b

m 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 g 4 4 4 4 4 4 4 4 4 n 7 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 5 1 1 w 1 1 1 1 1 1 1 a - - - - - - - - -

r C C C C C C C C C D M M M M M H M M M

$M C C C C C C C C C 1 T

I N-r U e

b C, C, m E u B A A A B A B

_ N 9 A 3 6 7 8 7 3 4 R

_ 7 4 3 9 4 4 9 8 8 T e 2 6 6 2 1 1 2 2 2 U v - -

N N

- - G c

l N N N N N N N

_ a R R R R R R R R R M 1

- V I I 1 I 1 I 1 1 4

O O e

0 Y System: Nuclear Service Water E E

= 0 g a

? &

O a ~  ?

E 2 Valve Category u O U

=

d 8 E Y Valve Number Drawing Number ~A B C D Remarks IRN-21A C MC-1574-1.1 J-2 X CT X CS 60 sec. max. cycle time IRN-16A C MC-1574-1.1 J-3 X CT 60 sec. max. cycle time IRN-22A C MC-1574-1.1 H-5 X CT X CS 60 sec. max. cycle time 4

j 1RN-28 C MC-1574-1.1 J-9 X MT j 1RN-68 C MC-1574-1.1 K-12 X CT 60 sec. max. cycle time IRN-40A C MC-1574-1.1 I-12 X CT 60 sec. max. cycle time i 1RN-41B C MC-1574-1.1 F-12 X CT 60 sec. max. cycle time

1RN-43A C MC-1574-1.1 F-12 X CT 60 sec. max. cycle time t

1RN-18B C MC-1574-1.1 E-2 X CT 60 sec. max. cycle time McGUIRE - UNIT 1 II.31-5 4

a

r e

t W

a e e e e e 6O 1

e m m m m m 3 c i i i i i i t t t t t I v e e I

r e e e e l l l l l S c y

c y

cy c y y c

r s c c c c c a k e r . . . . .

l a x x x x x a

c m a a a a u e m m m m m N R . .

c c c c c

e e e e e m s s s s s e

t 0 0 0 0 0 s 6 6 6 6 6 y

S

$UNed* ?Y$ S C

S C

0:?u ~dY X X T T T T T T 0E8a?& uE C C M C C C y D r

o g

t C

e a

C X O

B X X X X X e

l v

a A V

3 2 2 5 4 9 1 1 1 a%M E8" G C

E B

F F

r e

b m 1 1 1 1 1 1 u . . . . . .

N 1 1 1 1 1 1 g 4 4 4 4 4 4 n 7 7 7 7 7 7 i 5 5 5 5 5 5 w 1 1 1 1 2 2 a - - - - - -

r C C C C C C D M M M M M M EM C C C C C C 1 T

I

- N r U

_ e b -

m u E N B B 1 B A R 6 5 0 6 1 l l

e v

a 2

N R

2 N

R 3

N R

N R

1 4

N R

l N

R

- UO I

G c

V I 1 I 1 2 2 M

v ~ ~.)

$ $ System: Nuclear Service Water c . es 8 $ 6

. 8 8 3 3 1 l 4

,c4 m

$ u w

c l

E E Valve Category u 0 U-3 o E Y, E Valve Number Drawing Number A B C D H " P Remarks 1RN-166 C MC-1574-2.0 J-2 X CT 60 sec. max. cycle time IRN-70A C MC-1574-2.0 D-4 X CT 60 sec. max. cycle time IRN-69A C MC-1574-2.0 K-3 X CT 10 sec. max. cycle time

~

IRN-73A C MC-1574-2.0 I-4 X CT 60 sec. max. cycle time IRN-112 C MC-1574-2.0 J-5 X CT 60 sec. max. cycle time IRN-117 C MC-1574-2.0 J-7 X CT 60 sec. max. cycle time IRN-86A C MC-1574-2.0 D-9 X CT 60 sec. max. cycle time i

1RN-89 C MC-1574-2.0 I-9 X CT 60 sec. max. cycle time 4

1RN-140A C MC-1574-2.0 D-3 X CT 15 sec. max. cycle time McGUIRE - UNIT 1 II.31-7

r t

W e

a e e e e e e e e 8

1 O

e m m m m m m m m 3 c i i i i i i i i I

i t t t t t t t t v e e I

r e e e e e e e l l l l l l l c

l S c y

c y

c y

c y

c y

c y y c

y r s c c c c c c c c a k e r . . . . . . . .

l a x x x x x x x x c m a a a a a a a a u e m m m m m m m n N R . . . . . .

c c c c c c c c

e e e e e e e e m s s s s s s s s e

t 0 0 0 0 5 5 5 0 s 1 6 6 6 1 1 1 6 y

S

$U E0"N ?Y$

O:?a ~3U*

T T T T T T T T

$ESA?e u$" C C C C C C C C y

r o

D __

t C

g e

a C O B X X X X X X X X e

l v

a A V

0 1 2 6 3 7 7 9 1 1 1

%REO" C 1 C l I D C B 1 r

e b

m 1 1 1 1 1 1 1 1 u . . . . . . . .

N 2 2 2 2 2 2 2 2 g 4 4 4 4 4 4 4 4 n 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M M M M 1 i M H M C C C C C C C C 1 M" T I

N r U b

e m

u A A A A A F.

N 3 4 7 6 0 4 l

e v

0 1

N 1

8 N

3 1

N 3

1 N

2 1

N 3

1 N

l I

N 5

8 N

RO I

U G

c a R R R R R R R R M V 1 I I I I I I I

r e

t a 9 W -

e e e e e e e e e 1 e m m m m m m m m m 3 c

i vr i

L e

i t

e i

t e

i t

e i

t e

i t

e i

t e

i t

e i

t e

I I

e l l l l l l l l l S c c c c c c c c c y y y y y y y y y r s c c c c c c c c c

. a k

. e r . . . . . . . . .

. l c

a x x x x a

x x x x x a a a a a a a a m

u e m m m m m m m m m

- N R c c c c c c c c c m

e s

e s

e s

e s

e s

e s

e s

e s s e

e t 0 0 0 0 0 0 0 0 5 s 6 4 6 1 6 6 6 6 1 y

S

.>Ue0.M# EUM.[

~

eU.Ee OM."

UaE.U? 3 uM." T C

T C

T C

T C

T C

T C

T C

T C

T C

y D

. r o

g e C t

a

. C B X X X X X X X X X

_ e v

l a A V

3 2 4 4 4 5 7 9 9 1

$N3EOO J E I K J J D I D

- r e

_ b

_ m 0 0, 0 0 0 0 0 0 0 u

N 3 3 3 3 3 3 3 3 3

- g 4 4 4 4 4 4 4 4 4 n

- 7 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 a - - - - - - - - -

- r C C C C C C C C C D M M M M M M M M M

- E3Ho c C C C C C C C C C 1

- T

. I N

r U e

b -

m u B B B B B E N 0 4 2 3 '0 R

- e 7

1 1

7 1

7 1

6 1

1 2

8 1

2 7

8 1

9 1

0 4

2 I

U v - - - - - - - - - G N N N N l N N N N N c a R R R R R R R R R M V I 1 1 I I 1 1 I 1 3iI  ;  :) ,

0 U System: Nuclear Service Water E O E 8 e a a a 3

%  ? e 4 a ~ #

$ 2 Valve Category u O U M O $ Y $

Valve Number " " " #

  • Remarks Drawing Number A B C D 1RN-204B C MC-1574-3.1 C-5 X CT 15 sec. max. cycle time IRN-182 C MC-1574-3.1 I-3 X CT 60 sec. max. cycle time 1RN-235B C MC-1574-3.1 E-7 X CT 60 sec. max. cycle time IRN-2388 C MC-1574-3.1 I-7 X CT 60 sec. max. cycle time 1RN-227B C MC-1574-3.1 E-10 X CT 15 sec. max. cycle time IRN-231B C MC-1574-3.1 C-10 X CT 15 sec. max. cycle time IRN-215B C MC-1574-3.1 B-11 X CT 15 sec. max. cycle time IRN-186 C MC-1574-3.1 1-12 X CT 60 sec. max. cycle time l McGUIRE - UNIT 1 II.31-10 1 O O O

N.,

3 System: Nuclear Service Water 8 U O -

. 8 3 3 1 s 4

8  ? w g

  • g Valve Category y

t y

a g

v4 O G GD G3 Valve Number " " " " Remarks Drawir.g Number A B C D IRN-252B C HC-1574-4.0 E-2 X CT X CS Isolation time 530 sec.

LT 4 1RN-253A C MC-1574-4.0 C-2 X CT X CS Isolation time $30 sec.

LT 1RN-276A C HC-1574-4.0 J-2 X CT X CS Isolation time 530 sec.

LT 1RN-277B C MC-1574-4.0 1-2 X CT X CS Isolation time $30 sec.

LT 1RN-42A C MC-1574-4.0 B-9 X CT X CS 60 sec. max. cycle time j.

McGUIRE - UNIT 1 II.31-11 Revision 4 1

MC-1574-1.0 ,

VALVE: 1RN-63B, IRN-64A CATEGORY: B CLASS: C FUNCTION: Isolates Nuclear Service Water System Non-essential Header.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit cooling flow to several heat exchangers. This action could result in damage to the 4 equipment served by these heat exchangers. This equipment includes the PD charging pump and the computer room A/C.

ALTERNATE TESTING: This valve will be tested during cold shutdowns. ,

O l

9 l

l McGUIRE - UNIT 1 II.31-12 j Revision 4 t-

i i

\

4

! MC-1574-1.1 I

i VALVE: 1RN-21A, IRN-22A, IRN-25B, IRN-26B CATEGORY: B J

l CLASS: C 1 ,

4 FUNCTION: Regulate to backflush Nuclear Service Water Strainer IA &

i, 1B when D/P setpoint is reached.

4

{ TEST REQUIREMENT: Verify valve operability every three months.

i

) BASIS FOR RELIEF: These valves automatically regulate to provide flow j for backwashing the strainer. These valves are not 1 provided with sufficient manual controls to permit 4 testing. Normal operation should verify valve

! operability.

1 1

1 4 ALTERNATE TESTING: Valves will be timed at cold shutdowns.

3 i

b-f l

.ll

)

1 2

1 1

1

  • J 4

t i

f f

i j

i i

i i f i i

II.31-13 McGUIRE UNIT 1 Revision 4

,.. . . . .. . . _ . . . . _ _ ~ ., , , _ . . . _ . . _ . . _ . 4 , , - _ , _ _ _ . _ . .-.,o .

1 MC-1574-4.0 l llll l VALVE: 1RN-252B, IRN-253A 1

l CATEGORY: A CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: These valves must remain open to maintain cooling water to the Reactor Coolant Pump Motor Air Cooler. If one of these valves were to fail in the closed position during testing, the flow would be restricted. This action could result in damage to the Reactor Coolant Pump Motors.

ALTERNATE TESTING: These valves will be tested during cold shutdowns.

l O

t i

i e

! McGUIRE - UNIT 1 II.31-14 l

l

e 1 MC-1574-4.0 l VALVE: 1RN-276A, IRN-277B CATEGORY: A CLASS: B

)

FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: These valves must remain open to maintain the cooling water flow path for the Reactor Coolant Pump Motor Air Cnolers. If one of these valves were to fail in the closed position during testing, the flow would be restricted. This action could result in damage to the Reactor Coolant Motors.

ALTERNATE TESTING: These valves will be tested during cold shutdowns.

r O

1 O

McGUIRE - UNIT 1 II.31-15

MC-1574-4.0 ,

VALVE: IRN-42A CATEGORY: B  !

CLASS: C I FUNCTION: Isolates Nuclear Service Water System Non-essential Header.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit cooling flow charging pump. This action could result in damage to the equipment served by these heat exchangers. This equipment includes the PD 4

charging pump and the computer room A/C.

ALTERNATE TESTING: This valve will be tested during cold shutdowns.

O J

McGUIRE - UNIT 1 II.31-16 Revision 4

i I

i l SYSTEM: REACTOR COOLANT SYSTEM

~

FLOW DIAGRAMS: MC-1553-2.0 i

t MC-1553-4.0 l

l j

i i

I (

z ,

l i

4 1

d I

i

(

4 4

i 1

i i

i t

! McGUIRE - UNIT 1 II.32-1

$  !! System: Reactor Coolant

$ 0 8  :  !

a s =

%  ? e S a ~  !?

E 2 Valve Category u O Ij O

u 8 0 Y $

Valve Number Drawing Number u A B C D F' " E' Remarks 4 INC-36H A MC-1553-2.0 G-2 X CT X 2.0 second cycle time 4 INC-34A A MC-1553-2.0 G-3 X CT X 2.0 second cycle time 4 1NC-32B A MC-1553-2.0 G-5 X CT X 2.0 second cycle time INC-1 A MC-1553-2.0 K-3 X SP Set at 2485 PSIG INC-2 A MC-1553-2.0 K-4 X SP Set at 2485 PSIG INC-3 A MC-1553-2.0 K-5 X SP Set at 2485 PSIG INC-54A B MC-1553-2.0 11 - 9 X CT Isolation time $10 sec.

LT INC-53B B MC-1553-2.0 11 - 1 0 X CT Isolation time $10 sec.

LT ,

l INC-57 B MC-1553-2.0 F-13 X X LT Passive t

1 l

McG f RE - UNIT 1 II.32-2

4

. . n c c 3 o t e e - i

- n .

s s 2 s l

a c e 0 0 3. vi o s 6 6 I e _

o I R _

C 0 _

1 r $ e e o m m t s e i i

- c k m t t a r i

. e a t e e R m l l e n c c R o y y

i c c e e m t v v e a . . i i t

s l

o x x s s

s s

y s a a a a M M P P

- S I S S * * *

  • n5 a* ?U$H C C F R

F R

F R

F R

$$a& 3TM X X X X X X

~

TT T T T T T T CT CT T T B@0a?& u$e CL C C C C L L PL PL L L

- y D r

o g

e C X X t

_)' a C

. f( V e B X X X X l

v a A X X X X X X X V

4 1 1 1

9 9 1 1 8 8 7 6 7 7

_ =%R28u D H

D B

C 1

J J D C I

- r e

b m 0 0 0 0 0 0 0 0 0 0 0 u

N 2 2 2 2 2 4 4 4 4 4 4 g 3 3 3 3 3 3 3 3 3 3 3 n

- 5 5 5 5 5 5 5 5 5 5 5 i 5 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - - -

r C C C C C C C C C C C D M M M M M M M M M H M m@g B A A A A B B B B B B 1 T

I N

r U e

b -

m C, C, u A A B A E N B 2 3 C C 5 6 1 2 1 9 R 6 7 9 9 4 4 6 5 I 7 9 7 U

e 5 2 2 2 2 1 1 1 1 2 2 v - - - - - - - - - - - G c

l C C C C C C C C C C C a N N N N N N N N N N N M V I I I I I I I I I I I 4

!' , i . . 4

I 1

MC-1553-4.0 VALVE: INC-259, INC-261 CATEGORY: A, C CLASS: B FUNCTION: Thermal overpressurization relief.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASISFOR RELIEF: Valves have no indication of closure.

ALTERNATE TESTING: Valves will be verified shut by leak test performed in accordance with Appendix J.

O I

l l

O i

l l

McGUIRE - UNIT 1 II.32-4 l

l l

MC-1553-2.0 O VALVE: INC-36B, INC-34A, INC-32B CATEGORY: B J

] CLASS: A FUNCTION: Reactor Coolant System PORV.

TEST REQUIREMENT: Full stroke exercise quarterly.

l BASIS FOR RELIEF: PORV's do not serve a safety related function when i unit is at operating temperature and pressure. PORV's protect RCS from low temp. overpressurization.

4 ALTERNATE TESTING: Valves will be tested in accordance with technical specifications which require cycling of PORV every '

18 months.

I i

r i

tai McGUIRE - UNIT 1 II.32-5 Revision 4 New Page f

. - , - , 3 --

,. . . , . , , , ---------m ,- ,- - - - - -, I

MC-1553-2.0 O

VALVE: INC-272A,C, INC-273A,C CATEGORY: B CLASS: A FUNCTION: Reactor Vessel Head Vent TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: Opening of either of these valves during power operation could cause a loss of coolant.

ALTERNATE TESTING: Valves will be cycled at cold shutdown.

O l

II.32-6 O

McGUIRE - UNIT 1 Revision 4 New Page

I 6

l l; MC-1553-2.0 )

VALVE: INC-27, INC-29 i CATEGORY: B i

l CLASS: A 9

FUNCTION: Pressurizer Spray Control f TEST REQUIREMENT: Cycle and time valve quarterly.

BASIS FOR RELIEF: Valve has no open or closed indication.

ALTERNATE TESTING: Valve will be verified operable quarterly by partial stroking. A change in RCS pressure will indicate proper valve operation.

i 3

4 8

t b.

I t

1 4

f McGUIRE -. UNIT 1 II.32-7 Revision 4 New Page

SYSTEM: REFUELING WATER FLOW DIAGRAMS: MC-1571-1.0 l

i l

1 l

l l

l I

?

l.

j t

3 i

l' McGUIRE - UNIT 1 II.33-1 i

1

4 e e e e m m m m i i i i 2 r t t t t -

e g g g g 3 s t

a n n n n 3. vi W i t

i t

i t

i t

I I

e R

g a a a a n r r r r i e e e e l p p p p e s o o o o u k f r . . . .

e a x x x x R m a a a a e m m m m R

e e e e . . .

c m v v v v c c e

c e e e i i i i e t s s s s s s s s s s s s s y a a a a 0 0 0 0 S P P P P 1 1 1 1

$$EOd* ?Y$H F R

F R

F R

O:?8 ~ 3 T*

T T T T T T T T 3ESd?& u$H L L L L CQ CQ CQ CQ y D r

o _

g e C X t

a C

B X X X X e

l v

a A X X X X V

0 1 1 1 s 7 8 2 2 1 1 1 1 a%328u C D C D F F E E r

e b

m 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 g 1 1 1 1 1 1 1 1

. n 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5

_ w 1 1 1 1 1 1 1 1

_ a - - - - - - - -

r C C C C C C C C D H M M M  !

t M H M 1

_ B B B B B B B B

$Mu T

_ I N

r U e -

b m E u R N B A B 1 3 9 3 A 2 e 5 4 1 1 4 3 1 3 v - - - - - - - -

l a

W F

W F

W F

W F

W F

W F

W F

W F M c

V I 1 I 1 1 I 1 I 4 4 4

? .

o ,

vr t e e m

W a i t

g e _

n l _

i c l y e s c u k f r .

_ e a x

_ R m a e m R

._.  : . e m c v e e i t s s

. s s y 0 a S 3 P

$Un634 $Y: S F

- C R

.U 8?4c mO1* X

- T T T T

$ad81oN u " CQ MQ L M y D r

._ o g

_ /

e C X X X t

a C

B X e

_ v l

a A X V

2 1 1 1 1 5 3a028" C B

C I

._ r e

b m 0 0 0 0 u

N 1 1 1 1 g 1 1 1 1 n

_ 7 7 7 7 i 5 5 5 5 w 1 1 1 1 a - - - -

r C C C C D M M M M

$a B B B E 1 _

T _

I N _

r U

_ e b -

m E

.. u N A R 7 8 7 2 I e 2 2 6 5 U _

v - - - - G _

_ l W W W W c M

a F F F F _

V I I I I -

!1i . ;

i 1

MC-1571-1.0 VALVE: IFW-27A CATEGORY: B CLASS: B FUNCTION: Isolates low pressure inj. from RWST.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Closure of this valve would render all low pressure injection inoperable.

ALTERNATE TESTING: Valve will be cycled ard timed at cold shutdown.

O l

l l

9 McCUIRE - UNIT 1 II.33-4

t I

i j SYSTEM: RESIDUAL. HEAT REMOVAL SYSTEM

}

FLOW DIAGRAMS: MC-1561-1.0 l

i i

I l 1

1 l d

I J

1 i

i i

I 1

i McGUIRE - UNIT 1 II.34-1 1

i i

4

l a

v o

m e e e e e e e e e 2

4 O

R m m m m m m m m 3 i i i i i i i i t t t t t t t t t I

_ a I

_ le e e e e e e e e

_ l l l l l l l l l c c c c c c c c l y y y y y y y y a s c c c c c c c c u k d r . . . . . . . .

i a x x x x x x x x s m a a a a a a a a e e m m m m m m m m R R c c c c c c c c

e e e e e e e e m s s s s s s s s e

t 0 0 0 0 0 0 0 0 s 6 6 6 6 6 6 1 1 y

S

$UE0d*#UE S C

S C

O:?a ~OI# X X T T T T T T T T T T

$EBd?a u0" C C C C M M C C C C y D r

o t

C g

e a

C X X O

B X X X X X X e

v l

a A X X V

3 3 2 2 1 1 1 1 8 8 7 7 9 9

$ %578" I 1 1 E 1 1 J D F I I B L r _

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 1 1 1 1 1 1 1 1 1 1 n 6 6 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M H M M M M M M M M EM" A A B B B B B B B B 1 T

I N

r U e

_ b -

m u E N A B A

_ l e

v B

1 D

A 2

D B

4 D

9 1

D 3

2 D

8 D

8 1

D 3

3 D

7 6

D 8

6 D

- 6R U

G c

a N N N N N N N N N M

- N V I I I I I I I I I I

O O O f ,

System: Residual IIcat Removal

$ N

. 8 8 3 3 1  ?

" 4 8

l w

. 4  % 3 g g Valve Category g y g Valve Number U Drawing Number 0 A B C D

$ N $ Remarks 4 IND-71 B MC-1561-1.0 C-4 X MT X RF IND-14 B MC-1561-1.0 D-3 X CT 60 sec. max. cycle time 4 IND-70 B MC-1561-1.0 K-3 X MT X RF IND-58A B MC-1561-1.0 K-3 X CT X CS 60 sec. max. cycle time IND-29 B HC-1561-1.0 J-3 X CT 60 sec. max. cycle time IND-15B B MC-1561-1.0 E-3 X CT 10 sec. max. cycle time o

IND-30A B HC-1561-1.0 I-3 X CT 10 sec. max. cycle time IND-34 B MC-1561-1.0 G-5 X CT 60 sec. max. cycle time I

, McCUIRE - UNIT 1 II.34-3 Revision 4

I 1

i MC-1561-1.0 O

VALVE: IND-1B, IND-2A A

4l CATEGORY: l CLASS: A FUNCTION: Provides suction for Residual Heat Removal pumps during normal cooldown.

TEST REQUIREMENT: Verify proper valve movement every three months.

BASIS FOR RELIEF: These valves have been provided with an interlock which prevents their opening when the Reactor Coolant System 4 pressure is greater than 385 psig.

ALTERNATE TESTING: Valve will be cycled during cold shutdowns.

till O

II.34-4 McGUIRE - UNIT 1 Revision 4

l 1 MC-1561-1.0 t

l 4l VALVE: IND-70 l l 1

I CATEGORY: C 5 l i CLASS: B l

4l FUNCTION: RHR to SI Suction Check. l TEST REQUIREMENT: Full stroke exercise quarterly.

4 BASIS FOR RELIEF: IND-70 cannot be full stroked during power operation i or cold shutdown since the only full flow path is into

. the RCS and this can only be performed during refueling l outages when the reactor head is removed.

J

f. ALTERNATE TESTING: IND-70 will be full stroke exercised at refueling and 4 l' partial stroked quarterly.

i 1

l l

1 i

1 :f i'

j i,

o I

1 4

i i

j i

l i

i i

i s

! I f McGUIRE - UNIT 1 11.34-5 j Revision 4

. _ _ - . _ , . . _ . - _ _ _ _ _ . _ - . _ - - _ . ~ _ _ _-_- , _ . . . . . , -

MC-1561-1.0 O

VALVE: IND-58 CATEGORY: B CLASS: B FUNCTION: Provides suction to the Centrifugal Charging Pumps from the Residual Heat Removal System.

TEST REQUIREMENT: Cycle valve every three months.

BASIS FOR RELIEF: Due to interlocks in the Safety Injection System and the actual Residual Heat Removal System design, it is impossible to test these valves without rendering both trains of Residual Heat Removal and both trains of Safety Injection inoperable during operation.

ALTERNATE TESTING: Cycle and time at cold shutdown.

O O

McGUIRE - UNIT 1 II.34-6

. MC-1561-1.0 O VALVE: IND-71 CATEGORY: C CLASS: B FUNCTION: RER to SI Suction Check.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valve cannot be full stroked at power since the only full flow path is into the RCS and this can only be done with the reactor head removed at refueling.

IND-71 cannot be partial stroked during power since the required valve lineup would render both trains of safety injection inoperable. During cold shutdown,

. both SI pumps are tagged out to prevent a low tempera-ture overpressurization.

ALTERNATE TESTING: Valve will be full stroked at refueling.

l McGUIRE - UNIT 1 II.34-7 Revision 4 New Page

. . . . - . - . - . - - - . - - - - . . . - - - . -- - . - - - . . - . . ~ . . -

i l

-l l

SYSTEM: SAFETY INJECTION FLOW' DIAGRAMS: MC-1562-1.0 ,

MC-1562-2.0 MC-1562-2.1 MC-1562-3.0 MC-1562-3.1 MC-1562-4.0 l

l l l t

I I

l i

4 i

D

,e l

l l.

.i, 9

f i

-i

i i

-i I

L i

i e.

I' McGUIRE - UNIT 1 II.35-1

i t

n o

e m

e m

e m

e m

e m

e m

e m

e m

2 5

3

- O c i i i i i i i i e t t t t t t t t 1 j 1 n e e e e e e e e i l l l l l l l l

_ c c c c c c c c y y y y y y y y y t s c c c c c c c c e k

_ f r . . . . . . . .

a a x x x x x x x x S m a a a a a a a a e m m m m m m m m R

m c c c c c c c c e e e e e e e e e t s s s s s s s s s

y 0 0 0 0 0 0 0 0 S 1 1 1 1 1 1 1 1 o E0d* ED$ F R

F R

E0?E ~O$* X X T T T T T T T T T T OE0a?a u$" C C C C C C C C M M y D r

o O

g e C X X t

a C

B X X X X X X X X e

l v

a A V

0 0 1 1 8 7 5 6 4 4 2 1

%O28" E D

G G

I I

1 1

G G

K r

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 2 2 2 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M Ed B B B B B B B B B A 1 T

I N

r U e

b -

m E u

N A A A R B R A B 1 5 3 A 0 2 5 I l

e v

a 4

I N

5 I

N 4

I N

2 I

N 2

I N

/-

2 I

N 9

I N

1 I

N 1

I N

1 I

N

- UO G

M c -

V I I 1 I 1 1 I I I I

,' llli!

4 _

Oo n

. n 3oi i e 5s t m

_ c i 3. vi e t Ie j IR n e I l c

._ y y

_ t s c e k f r .

a a x S m a e m R .

m c e e

_ t s

_ s y 0 S 6

. $UEed* FUE F R

F R

F R

F R

F R

F R

F R

S C

O:?a OY X X X X X X X X T T T T T T T T 0ESa?a u$ M M M M M M M C y D r

o O

g e C X X X X X X X t

a

_ C B X e

_ l v

a A

_ V

. %5U0" 1 1

1 1

1 1

1 4

I I F F D D K J

_ r e

b m 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 2 g 2 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M H M M M H M M EM" A A A A A A A B 1 T _

I _

N _

r U _

e b -

m E u B R

N 7 8 9 4 1 O 7 4 4 1 I 9 4 5 3 e 1 3 1 3 2 3 3 4 U l

v I I

I I

I I

I

- - G c

I

- a N N N N N N N N M V I I I I I I I I 4

l 4

n 4 o -

i e . 5s t m c 3. vi c i e e t s I e j IR n e 5 I l 1 c 5 y y t s c e e k m f r . i a a x t S m a .

e m n R o

. i m c t e e a t s l s o y 0 s S 6 I

$$E0"

  • EY$H SF SF S SF CR SF CR F

R CR CR C O?& ~ 3 $* X X X X X X TT TT T TT TT TT TT

$ESa?& u$H LM LM C LM LM CL ML y D r

o t

C g

e a

C B

X X X

X X X 4

e v

l a A X X X X X X V

3 3 4 1 4 4 1 1 5 3

%3?8o - - - - - - -

1 1 H E D D K K r

e b

m 0 0 0 0 0 0 0 u

. N 2 2 2 2 2 2 2 g 2 2 2 2 2 2 2

_ n 6 6 6 6 6 6 6

_ i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 a - - - - - - -

r C C C C C C C D M M M H M M M 1

A A B A A B B EMo T I

N r U e

b -

m E u A R N 0 A I 0 1 3 9 0 7 8 l

e v

a 7

I N

7 I

N 4

I N

5 I

N 6

I N

4 I

N 4

I N

- U9 G

M c

V I I I 1 I I I l

4

O 3 >

e 3 U System: Safety Injection 0 E

! E O E  : a *

%  ? u 3 & ~  ?

E E Valve Category u O Y N "

8 E U E

H Valve Number Drawing Number A B C D Remarks INI-81 A MC-1562-2.1 C-3 X X LT X CS MT RF INI-82 A MC-1562-2.1 C-3 X X LT X CS MT RF 4 INI-93 A MC-1562-2.1 C-8 X X MT X CS LT 4 INI-94 A MC-1562-2.1 C-8 X X NT X CS LT INI-95A B MC-1562-2.1 F-11 X CT Isolation time $10 sec.

LT INI-96B B MC-1562-2.1 E-14 X CT Isolation time $10 sec.

LT 4 1NI-436 B MC-1562-2.1 G-11 X X NT X RF* Passive LT McGUIRE - UNIT 1 II.35-5 Revision 4

$ $ System: Safety Injection E $ 0 S  : 0 d  ? #

%  ? a 3 a ~  ?

E 3 Valve Category u 3 $

M o

0 $

H 0

H Valve Number Drawing Number A B C D Remarks INI-334B B MC-1562 3.0 L-11 X CT 10 sec. max. cycle time INI-333B B MC-1562-3.0 L-12 X CT 10 sec. max. cycle time INI-332B B MC-1562-3.0 L-14 X CT 10 sec. max. cycle time 1NI-136B B MC-1562-3.0 C-14 X CT 10 sec. max. cycle time 1NI-103A B HC-1562-3.0 I-14 X CT 10 sec. max. cycle time INI-101 B HC-1562-3.0 F-14 X MT X INI-100B B MC-1562-3.0 F-13 X CT X CS 10 sec. max. cycle time 1NI-135B B MC-1562-3.0 E-14 X CT 10 sec. max. cycle time 1NI-114 B MC-1562-3.0 I-9 X MT INI-115B B MC-1562-3.0 11 - 9 X CT 10 sec. max. cycle time McGUIRE - UNIT 1 11.35-6 O O O

._ _ ._ _ _ ._ __. _ .m__ __ . _ _ _ . _ . _ _ . ..

m w O

h

/

5 E U System: Safety Injection E O E S  : -

a  ? y

%  ? u

. 0 0  % $

g g Valve Category y j g Valve Number Drawing Number A B C D Remarks INI-147A B MC-1562-3.0 G-11 X CT X CS 10 sec. max. cycle time INI-144B B MC-1562-3.0 G-9 X CT 10 sec. max. cycle t.ime 1NI-143 B MC-1562-3.0 F-9 X MT i

INI-116 B MC-1562-3.0 J-9 X MT X RF INI-148 B MC-1562-3.0 D-9 X MT X RF INI-118A B MC-1562-3.0 li-7 X CT 10 sec. max. cycle time INI-150B B MC-1562-3.0 E'-7 X CT 10 sec. max. cycle time INI-120B B MC-1562-3.0 J-7 X CT Isolation time <10 sec.

LT 1NI-121A B MC-1562-3.0 J-6 , X CT Isolation time $10 sec.

McGUIRE - UNIT 1 II.35-7

i n

o

. e e 8

5

- O t c m m 3 c e i i e s t t I j I n 0 e e I l l 1_

< c c y y y t s e c c e k m f r i . .

a a t x x S m a a e n m m R o . .

i m t c c e a e e t l s s s

y o

s 0 0 S I 2 1

$Uho" * ?UE* F R

S C

S C

F R

S C

O$?u ~3U* X X X X X T TT TT TT TT TT T T 0E00?& u0H C LM LM LM LM LN C C y D r

o t

C g

e a

C X X X X X O

B X X X e

v l

a A X X X X X V

4 4 4 3 3 2 3 6

%3?8O K I

1 1

1 I

J G

D r

e b

m 0 0 0 0 0 0 0 0 u

N 3 3 3 3 3 3 3 3 g 2 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 a - - - - - - - -

r C C C C C C C C D M M M M M M M M

@jo B A A A A A B B I T

I N

r U e

b -

m E u B B B R N 2 8 4 9 4 6 3 2 I 2 2 3 2 2 2 8 5 l

e v

a N 1

I 1

I N

1 I

N 1

I N

1 I

1 I

1 I

1 I

- UO G

M c

N N N N V I I I I I I I I

4 Oo i t

n c

9 5

3 i i

n o

s e v j

I I

e n R I

y t s e k f r a a

~ S m e

R

- m e

- t

- s y

S eUEtd* #Ya F R

F R

F R

F R

S C

. OEa ~OY# X X X X X T T TT TT TT TT E@8M?a u:

ML ML LM LM LN y D r

o g

. O t C

e a

C B

X X X X X a

- l v

a A X X X X X V

4 3 3 2 3

- $n528" B B

D

- D I r

e b

m 0 0 0 0 0 u

N 3 3 3 3 3

. g 2 2 2 2 2 n 6 6 6 6 6 i 5 5 5 5 5 w 1 1 1 1 1 a - - - - -

r C C C C C D M M M M M A A A A A 1

$a T

I N

r U e

b -

m u

0 E N 9 6 6 7 5 R O 5 5 5 2 1 I e 1 1 1 1 U v - - - - - G l I I I I I c a N N N N N M V I I I I I 4 4 4

,; 4

iI l ,I l l l 4

0 n 1 o e i e e 5 s t m m m 3 i c i i i t

v e t t I I

e j

e R n e e l I l l c c c y y y y t s c c c e k f r . . .

a a x x x S m a a a e m m m R . .

m c c c e e e e t s s s s

y 0 0 0 1

S 1 1

$Uf md* ?Y$" S C

F R

F R

F R

F R

S C

S C

S C

0?& ~3U# X X X X X X X X

$6Sa?& u$H T C T T._ TMLT_

f f 1 T

M T. T TT_

ML T

C TT M L T

M L T T C T T ML y D r

o g

e C X X X X X X X t

a C

B X X X e

v l

a A X X X X X X X V

1 2 2 1 7 6 5 3 1 8 8 1 5 a%R38 K J

J I

F F

J J 1 I I r

e b

m 1 1 1 1 1 1 1 1 1 1 u . . . . . . . . . .

N 3 3 3 3 3 3 3 3 3 3 g 2 2 2 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 1 1 1 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M 1

B A A A A B A A B A 8do T I

N r U e

b -

m E u A A B R

N 2 1 9 7 5 3 5 6 8 0 I 6 7 6 6 6 7 7 7 7 8 e 1 1 1 1 1 1 1 1 1 1 U v - - - - - - - - - - G l I I I T I I I I I 1 c a N N N N N N N N N N M V I I I I I I I I I 1

- l l l l l l l 4 4 4 4 4 4 4

- . . _ . _ . _ _ _ _ _ ~ . . . . . - . ... - . - - . . . _ . _ _ - - - . . . . - - - - . . .. . -

A .

s System: Safety Inject. ion h

8 $ d m 0 $ 0 3 1 s

  • 4 -

a l w m & E  ?

g g Valve Category g g g U Drawing Number O $ $ $

Valve Number A B C D Remarks 4l INI-181 A MC-1562-3.1 F-5 X X MT X CS l

LT INI-184B B MC-1562-3.1 D-12 X CT X RF 60 sec, max. cycle time INI-1858 B MC-1562-3.1 B-12 X CT X RF 60 sec. max. cycle time INI-358A B MC-1562-4.0 C-12 X CT 10 sec. max. cycle time 1

INI-244B B HC-1562-4.0 F-18 X CT 3 sec. max. cycle time INI-242B B HC-1562-4.0 E-8 X CT 3 sec. max cycle time INI-245A B HC-1562-4.0 F-7 X CT 3 sec. max. cycle time McGUIRE - UNIT 1 11.35-11 Revision 4

l l e

2 n 1 o -

i e e e . . . 5 s t m m m c c c 3 i

_ c i i i e e e v e t t t s s s I e -

j I R n e e e 0 0 1

0 1

_ I l l l 1 c c c $ 5 $ -

y y y y

_ t s c c c e e e e k m m m

_ f r . . . i i i x x a x t a t t

- S m a a a e m m m n n n

_ R o o i o

. . . i i m c c c t t t e e a e a a a c s

- t s l l l s o o o y 3 0 0 s s s S 1 1 I I I

$YE0d# ?U$H O ?e 0$# X X T Tr r TT TT T TT

- $ E" a?& u$H T C C T

C Ln Tr L3 CL CL L CL y D r

o g

e C X X X t

a C

B X X X e

v l

a A X X X X X V

_  %%338 7

5 5

5 3

3 4

2 3

E F F E E E E G G r

_ e b

m 0 0 0 0 0 0 0 0 0 u

N 4 4 4 4 4 4 4 4 4

_ g 2 2 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 5 w

a 1

1 1

1 1

1 1

1 1

r C C C C C C C C C D M M M M M M M M M

$Mo B B B A A A A B B 1 T

I N

r U e

b -

m E u A B A A N 3 8 5 8 9 6 7 6 4 4 5 5 4 4 6 6 3 6 e 2 2 2 2 2 2 2 3 2 l

v I I

I I

I I

I I

I c

a N N N N N N N N N M V 1 I 1 I I 1 I I I l l 4 4

4 3 n C i n

o 1 o

- i 5 s t

c e

c e

3.

1 e vi j p 1 R n s I

y h t s c

- e k e _

f r t a a S m r e e R p m d e e t t s s

_ y e S T

$YN0d* ?U$ F R

F R

F R

F R

O a& ~0Y" X X X X TT TT TT TT 0E8a?& uE LM LM LM LM y D X r

o O

g e C X X X X t

a C

B e

v l

a A X X X X V

6 4 3 2 8

' $M3E8" - - - - -

C C C C I r

e b

m 0 0 0 0 0 u

N 4 4 4 4 4 g 2 2 2 2 2 n 6 6 6 6 6 i 5 5 5 5 5 w 1 1 1 1 1 a - - - - -

r C C C C C D M M M M M Ed A A A A B 1 T

I N

r U e e -

b r m u E u t R N 3 2 1 0 p I O l e

v a

5 2

I N

5 2

I N

5 2

I N

5 2

I N

R u

I s l

l i c

U C

M c

V I I I I UD 4

l MC-1562-1.0 O

VALVE: INI-15, 1NI-354, 1NI-17, 1NI-347, INI-19, 1NI-348, 1NI-21, INI-349 CATEGORY: C CLASS: A

. FUNCTION: Opens on flow from BIT.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Full or partial stroke during power operation would result in thermal shock to injection nozzles. Valve cannot be stroked during shutdown due to possible low temperature overpressurization.

ALTERNATE TESTING: Valve sill be full stroked at refueling.

O l

1 O

McGUIRE - UNIT 1 II.35-14

j j MC-1562-1.0

! VALVE: INI-12 i

i CATEGORY: C

! CLASS: B

} FUNCTION: Opens on flow from BIT.

1 i TEST REQUIREMENT: Full stroke exercise quarterly.

i 1

i BASIS FOR RELIEF: Full or partial stroke during power operation would

! result in thermal shock to injection nozzles. Valve

{ cannot be stroked during shutdown due to possible low l temperature overpressurization.

i l ALTERNATE TESTING: Valve will be full stroked at refueling.

1 i

l 4

i 4

i a

)

i A

i t

4 I

i i

I l

i i

t i

I  ;

1 l McGUIRE - UNIT 1 II.35-15 i

r

- - - - . . - - - ,- - , . - - - , - , , , , - . , - , . - - - - - - - , . . . , , - - ,,,...-,,,,.,,,--.----,n -

MC-1562-2.0 O l VALVE: INI-430A, 1NI-431B CATEGORY: B CLASS: B FUNCTION: Supplies air to low pressure PORV's during blackout.

TEST REQUIREMENT: Cycle time quarterly.

BASIS FOR RELIEF: Valves are interlocked closed when RCS temperature is above 300 'F.

ALTERNATE TESTING: Valves will be cycle timed at cold shutdown.

O l

O McGUIRE - UNIT 1 II.35-16

I I

! i i' MC-1562-2.0 l

! VALVE: INI-48 I

CATEGORY: A, C CLASS: B ,

I-4 FUNCTION: Provides containment isolation.

i l TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF
Valve has no indication of closure.

!; ALTERNATE TESTING: Valve will be verified shut by leak test performed j in accordance with Appendix J.

I t

i I

i 2

.Bv e.. .

i 4

i t .

1 l

d i

I

~

  • f McGUIRE - UNIT 1 II.35-17

(

...,-...,wm, . , , , , , . , , , , , , , , , , , . _ . _ , , , , , , m.g., _m...,

I MC-1562-2.0 4 j MC-1562-2.1 1

4 VALVE: INI-81, 1NI-70, 1NI-59, 1NI-93 1

CATEGORY: A, C i CLASS: A l 4 FUNCTION: Opens on flow from the NI cold leg accumulator to the l l

Reactor Coolant System.

TEST REQUIREMENT: Verify valve opens when Reactor Coolant System pressure decreases below Safety Injection System pressure.

BASIS FOR RELIEF: Valves cannot be full or partial stroked during power operation since the accumulator pressure is % 425 psi 4 and cannot overcome RCS pressure. During cold shutdown exercising these valves could result in a low temperature overpressurization of the RCS.

ALTERNATE TESTING: Valves will be partial stroked during cold shutdowns, but not more often than once per nine months. Valves will be full stroked at refueling.

O O

II.35-18 McGUIRE - UNIT 1 Revision 4

i i I

^

MC-1562-2.1 l

\

l VALVE: INI-436 CATEGORY: A, C CLASS: B j FUNCTION: Provides containment isolation.

a 4

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valve has no indication of closure.

1 4

ALTERNATE TESTING: Valve will be verified shut by leak test performed in accordance with Appendix J.

J l

1 I

j l.

I J

i i

l II.35-19 McGUIRE - UNIT 1 f

)

1

_ _ _ _ _ _ _ _ . _ . _ _ _ _ . - ~ , _ . . _ . . _ . . . _ _ . _ . _ . _ . - , . , , _ _ . _ , ...

..._.._.,,__-....__.._.-_J

4 MC-1562-2.0 MC-1562-2.1 l l

4 VALVE: 1NI-82, 1NI-71, 1NI-60, 1NI-94 CATEGORY: A, C CLASS: A FUNCTION: Opens on flow ~from the NI System to the Reactor Coolant System.

TEST REQUIREMENT: Verify valve opens when Reactor Coolant System pressure decreases below Safety Injection System pressure.

BASIS FOR RELIEF: Valves cannot be full or partial stroked at power since a driving head to force the valves open does not exist.

4 ALTERNATE TESTING: Valve will be full stroked during cold shutdowns, but no more often than once per nine months.

O i

McGUIRE - UNIT 1 II.35-20 Revision 4

4 MC-1562-3.0 i

VALVE: INI-101 CATEGORY: C CLASS: B FUNCTION: Opens on flow from RWST to SI.

TEST REQUIREMENT: Full stroke exercise quarterly.

Bl. SIS FOR RELIEF: Valve cannot be full stroked at power since the SI pumps cannot overcome RCS pressure. During cold j shutdown this valve cannot be full stroked since 4 4 this could result in a low temperature overpressuri-j zation. .

, ALTERNATE TESTING: Valve will be partial stroked quarterly and full 4

stroked at refueling.

i 1

4 O

l i

i i

l 1

l l

McGUIRE - UNIT.1 II.35-21

' Revision 4 l

l l

MC-1562-3.0 9

VALVE: INI-100B, FWST to Safety Injection Pumps CATEGORY: B CLASS: B FUNCTION: Isolates St.fety Injection Pump Suction from FWST.

TEST REQUIREMENT: Cycle and time Valve Quarterly.

BASIS FOR RELIEF: Failure of valve in closed position would isolate suction from FWST to both safety injection pumps.

4l This would render both trains of SI inoperable. l ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

O O

McGUIRE - UNIT 1 II.35-22 Revision 4

i  !

MC-1562-3.0 i

4 l VALVE: INI-147A Safety Injection Pumps Miniflow Header  ;

to FW

) CATEGORY: B i

! CLASS: B i

t 4 FUNCTION: Isolation valve for safety injection miniflow to FWST. l 4

TEST REQUIREMENT: Cycle and time valve quarterly.

BASIS FOR RELIEF: If valve fails in closed position, the recirculation

, flow path for the safety injection pumps is isolated. If l a safety injection signal occurs with NC system pressure l above shutoff head for the pumps, the pumps would not have 4 a flow path. This would result in damage to the pumps.

l ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

4

)

j i

j i

i i 1

i

}

McGUIRE - UNIT I 5~

IRe' vision 4 1

_- - . . . . - . . . _ . ... . . ~ . .. . . . , _ _ _,.- --. , _ ,- , _ _ . . . - , _ _ . -

l l

MC-1562-3.0 j VALVE: 1NI-ll6, 1NI- 148 e ;

1 CATEGORY: C CLASS: B FUNCTION: Opens on flow from the NI Pump (s).

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: Valves cannot be full or partial stroked during power operation since the safety injection pumps cannot overcome RCS pressure. Valves cannot be stroked at 4

cold shutdown since this could result in a low tem-perature overpressurization.

ALTERNATE TESTING: Valve will be cycled open during refueling.

O II.35-24 McGUIRE - UNIT 1 Revision 4

i MC-1562-3.0 l VALVE: INI-128, 1NI-159, IN1-160, 1NI-156, INI-124, 1NI-157 CATEGORY: C

]

j CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIRENENT: Verify proper valve movement once per three months.

i BASIS FOR RELIEF: Valves cannot be full or partial stroked during power operation since the safety injection pumps cannot discharge into the RCS at operating pressure. During 4

cold shutdown, these valves cannot be full or partial

] stroked since this could result in low temperature j overpressurization.

ALTERNATE TESTING: Valves will be cycled open during refueling.

i i

1

'h o

I

\

McGUIRE - UNIT 1 II.35-25 Revision 4

MC-1562-3.0 O

VALVE: INI-129, 1NI-125, 1NI-134, INI-126 CATEGORY: C CLASS: A FUNCTION: Opens on flow from the NI to NC System.

TEST REQUIREMENT: Verify valve opens on flow from safety injection pumps once per three months.

BASIS FOR RELIEF: The discharge pressure of the safety injection pumps (1520 psig) is not sufficient for opening the valve to the Reactor Coolant System (2235 psig) during power operation.

RHR pumps, also, do not develop enough discharge pressure 4

to overcome RCS pressure at power operation.

4l ALTERNATE TESTING: Valve will be full stroke exercised during cold l shutdowns, but not more often than once per nine months.

O O

McGUIRE - UNIT 1 II.35-26 Revision 4

1 2

MC-1562-3.1 3

! VALVE: INI-162A Safety Injection Pumps Cold Leg Inj. Header CATEGORY: B

. CLASS: B FUNCTION: Provides isolation of Safety Injection Pumps from cold legs during hot leg recirculation.

TEST REQUIREMENT: Cycle and time valve quarterly.

BASIS FOR RELIEF: Failure of valve in closed position would completely isolate both trains of safety injection during the initial injection phase.

ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

i l,

1 1

4

)

i 1

1 4

McGUIRE - UNIT 1 II.35-27

i l

MC-1562-3.1 O

VALVE: INI-165, 1NI-167, INI-169, 1NI-171 CATEGORY: A, C CLASS: A FUNCTION: SI discharge check valves.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valves cannot be cycled during power operation since the SI pumps cannot overcome RCS pressure to permit 4 flow through the valves. During cold shutdowns exercising these valves could result in low tempera-ture overpressurization.

ALTERNATE TESTING: Full stroke exercise at refueling.

O O

II.35-28 McGUIRE - UNIT 1 Revision 4

4 MC-1562-3.1 I

, 4l VALVE: INI-180, INI-181, 1NI-175, INI-176 i

j CATEGORY: A, C i

! CLASS: A

.i l FUNCTION: Opens on flow from the ND or NI to NC System.

j TEST REQUIREMENT: Verify valve opens on flow from NI or ND System to i the NC System once per three months.

BASIS FOR RELIEF: The discharge pressure of the NI and ND Pumps is not sufficient for opening the valve to the Reactor Coolant System during power operation.

i l ALTERNATE TESTING: Valve will be tested for proper movement during cold

{ shutdowns, but not more often than once per nine months.

l 1

1 i.

l.

i j

i l

1 l

i i

i 4

McGuire - UNIT 1 II.35-29 Revision-4 4

4 y , . . - - - - .

m ________ n <-_ - . . - , . _ ~ , _ , - . , . , ,

MC-1563-3.1 l

VALVE: INI-184, 1NI-185 I l

I CATEGORY: B l 1

CLASS: B FUNCTION: Isolate the containment sump (1NI-184 isolates train B, 1NI-185 isolates train A). These valves also provide an alternate source for suction to the Residual Heat Removal Pumps.

BASIS FOR RELIEF: Due to interlocks in the Safety Injection System and the actual Residual Heat Removal design, it is impossible to test these valves without rendering both trains of Residual Heat Removal and both trains of Safety Injection 4 inoperable. During cold shutdowns, the RHR pumps are required for decay heat removal.

ALTERNATE TESTING: Full stroke exercise during refueling.

O f

9 McGUIRE - UNIT 1 II.35-30 Revision 4

i 4

MC-1562-4.0 i

l l VALVE: INI-248, INI-249, INI-250, 1NI-251, INI-252, 1NI-253 i} CATEGORY: A, C i.

CLASS: A l

FUNCTION: Open when Reactor Coolant System pressure decreases below 1500 psig during accident conditions.

TEST REQUIREMENT: Verify valves open on flow from upper head injection 3

accumulator.

i BASIS FOR RELIEF: The pressure in the UHI accumulator (1500 psig) is i not sufficient to open the valves into the Reactor Coolant System (2235 psig). At cold shutdown, the

! 4 high velocity water could cause damage to reactor

, internals. This, also, could cause low temperature

overprescurization, j 4 l ALTERNATE TESTING
Valves will be full stroked at refueling by disassembly. l I

1 l

1 4

i.

1 i

1 i

i i

j i

1 4

t McGUIRE - UNIT 1 II.35-31 i

Revision 4

SYSTEM: STATION AIR FLOW DIAGRAMS: MC-1605-2.2 1

1 1

l I

McGUIRE - UNIT 1 II.36-1

2 6

O c 3 e

r s I i I A 5 1

n $

o i s e t k m a r i t a t S m e n R o i

m t e a t l s

y o

s S I

$Y*E04 w5go" F F R R 0.$?* %ye# X TT TT 06a01E" a oH CL HL y D r .

o C

g e

t a

C X O B

e v

l a A X X V

5 5 m0$Mgo" - -

K I r

e b

m 2 2 u

N 2 2 g 5 5 n 0 0 i 6 6 w 1 1 a - -

r C C D M M

.ga B B 1 T

I r N U

e b -

m u E N B l

e v

2 S

1 3

1 S

- RO I

U G

c a V V M V I I

I MC-1605-2.2 i

VALVE: IVS-13 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve move:nent once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified shut by leak test performed in accordance with Appendix J.

10 d

4 t

l l

O McGUIRE - UNIT 1 II.36-3 i

. . - _ . . _ . . . ~ . . . . . . . _ _ . . - . . _ - , _ - - . . . _ _ _ _ . _ _ . . _ _ _ _ . . , . . ,

4 SYSTEM: STREAM LENERATOR BLOWDOWN RECYCLE FLOW DIAGRAMS: MC-1580-1.0 I

.O ma i

McGUIRE - UNIT 1 II.37-1

0 System: Steam Generator Blowdown Recycle E

S E U $-

N E m U M $ uM $"

E 2 Valve Category u OE U M o E UE Valve Number Drawing Number A B C D Remarks BB-1B B HC-1580-1.0 11 - 2 X CT Isolation time $10 sec.

Q BB-5A B MC-1580-1.0 F-2 X CT Isolation time $10 sec.

Q BB-2B B MC-1580-1.0 11- 4 X CT Isolation time slo sec.

Q BB-6A B MC-1580-1.0 F-4 X CT Isolation time $10 sec.

Q BB-3B B HC-1580-1.0 li-10 X CT isolation time $10 sec.

Q BB-7A B MC-1580-1.0 F-10 X CT Isolation time $10 sec.

Q BB-4B B MC-1580-1.0 11 - 1 2 X CT Isolation time $10 sec.

Q McGUIRE - UNIT 1 11.37-2 O O O

l e -

c y 3 c -

e . . . . . 7 R c c c c c 3 e e e e e n s s s s s I w I o 0 0 0 0 0 d 1 1 1 1 1 w $ $ $ $ $

o l s e e e e e B k m m m m m r i i i i i r a t t t t t o m t e n n n n n a R o o o o o r i i i i i e t t t t t n a a a a a e l l l l l

_ G o o o o o s s s s s m I I I I I

. a

. e S

t 3tE3%

. wSga m ,

e *:g&

t

- s 13&

y

. S

. T T T T T mgina?* ye l

CQ CQ Cq CQ CQ y D

, r o

g l t e C

. a C

_ B X X X X X e

l v

a A v

2 3 0 38ago 1 2 4 1 1 F D D D D r

._ e b

m 0 0 0 0 0 u

N 1 1 1 1 1 g 0 0 0 0 0 n 8 8 8 8 8

- i 5 5 5 5 5 w 1 1 1 1 1 a - - - - -

r C C C C C

- D M M M M M

.gu B B B B B 1

T _

I _

r N _

. e

  • U .

b m -

u N E R

O 0 1 2 3 e A 4 4 4 4 I v 8 1 1 1 1 U l - - - - - G a B B B B B c V B B B B B M

' 4 ' ,

i 1

l l 1 i

4 1

l DUKE POWER COMPANY l

i i McGUIRE NUCLEAR STATION 4

l ,.

4 PUMP AND VALVE INSERVICE TESTING i

j UNIT 2 i L I

1 1

l l

l l

l

- DUKE POWER COMPANY (3 MCGUIRE NUCLEAR STATION PUMP AND VALVE INSERVICE TESTING PROGRAM Table of Contents Section I. Pump Inservice Testing Program Introduction and Description ................................. I.1 II. Valve Inservice Testing Program Introduction ................................................. II.1 Table of Abbreviations ....................................... II.2 Definitions of Testing Requirements and Alternatives . . . . . . . . . II.3 General Relief ............................................... II.4 Systems:

i II.5 Annulus Ventilation (VE) .....................................

Aux il a ry Fe e dwa te r ( CA ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II.6 Boron Recycle (NB) ........................................... II.7 Breathing Air (VB) ........................................... II.8 Chemical and Volume Control (NV) ............................. II.9 Component Cooling (KC) ....................................... II.10 Containment Air Release and Addition (VQ) .................... II.11 Containment Air Return Exchange and Hydrogen Skimmer (VX) .... II.12

, gs Containment Purge Ventilation (VP) ........................... II.13 l Containment Spray (NS) ....................................... II.14 Containment Ventilation Cooling Water (RV) ................... II.15 Control Area Chilled Water (YC) .............................. II.16 Diesel Generator Engine Fuel Oil (FD) ........................ II.17 Diesel Generator Room Sump Pump (WN) ......................... II.18 Diesel Generator Starting Air (VG) ........................... II.19 Equipment Decontamination'(WE) ............................... II.20 Feedwater (CF) ............................................... II.21 Fire Protection (RF) ......................................... II.22 Ice Condensor Refrigeration (NF) ............................. 11.23 Instrument Air (VI) .......................................... II.24 Liquid Waste Recycle (WL) .................................... II.25 Main Steam (SM)............................................... II.26 Main Steam Supply to Auxiliary Equipment / Turbine Exhaust (SA) ............................. II.27 i Main Steam Vent to Atmosphere (SV) ........................... II.28 1 Makeup Demineralized Water (YM) .............................. II.29 Nuclear Sampling (NM) ........................................ II.30 Nuclear Service Water (RN) ................................... II.31 Reactor Coolant (NC) ......................................... II.32 Refueling Water (FW) ......................................... II.33 Residual Heat Removal (ND) ................................... II.34 S a f e ty I nj e c ti o n (NI ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II.35 Station Air (VS) ............................................. II.36 Steam Generator Blowdown Recycle (BB) ........................ II.37

\

, \s McGUIRE - UNIT 2

, DUKE POWER COMPANY s MCGUIRE NUCLEAR STATION PUMP INSERVICE TESTING PROGRAM ASME SECTION XI, SUBSECTION IWP i

The inservice testing of ASME Code Class 1, 2, and 3 pumps provided with an emergency power source will be tested as required by Section XI, Subsection IWP, of the ASME Boiler and Pressure Vessel Code 1980 Edition, except where specific written relief has been granted by the Commission. A description of 4 the proposed inservice testing program, as well as specific requests for relief from code requirements determined to be impractical, is described by the following. l i

I. The following are specific requests for relief from certain code j i requirements.

i A) IWP-4120 requires the full scale range of each instrument to be  !

] three times the reference value or less. This was changed from i j four times the reference value in the edition of Section XI that was 1 in effect prior to unit licensing. 10CFR, Section 50.55a(g)(4) states that design provisions are excluded from the requirement to upgrade to subsequent editions of Section XI. Since any cases where the three-times reference value criterion is not met would require  ;

design changes in instrumentation, we will continue to apply the four-times reference value criterion, as interpreted in B) below, for instrument accuracy evaluation.

B) In several cases, instrumentation does not meet the four times reference value criterion. These cases predominantly involve suction pressure gauges where a larger range is required to accommodate varying conditions at the suction of the pump. In all cases where the four-times reference value criterion cannot be met, an instrument error evaluation is performed to demonstrate that the overall accuracy of the differential pressure measurement is within the limits established by IWP. These cases are RHR discharge, nuclear service water suction, and control room chilled water suction gages.

C) Table IWP-3100-1 establishes the parameters that are to be i

measured. The previous edition of Section 11 specified that in a fixed resistance system, either AP or Q was to be measured, not both. The centrifugal charging pumps are tested using fixed resistance flow paths, with no flow indication provided. Based on the design change exclusion provided by 10CRF50.55a(g)(4), we will continue to apply the criterion that it is not required to measure flow in a fixed resistance system.

D) Table IWP-4110-1 states that vibration measurement should have an  ;

accuracy of + 5%. McGuire has no permanently installed vibration l

instrumentation. The portable instruments used to measure vibration ,

i have an uncertainty of + 11%.

! McGUIRE - UNIT 2 I.1-1 I

I f

6

, , , ~ , , , - . . - - . - , - - , , - , - - - . , , ,. ,y- w,--+- ,.4-- - - - , ,c,.,-,

II. The following Safety Class 1, 2, and 3 pumps (See Attachment #1 for specific safety class and available instrumentation) will be tested in accordance with the intent of Subsection IWP of the ASME code:

NUCLEAR SERVICE WATER PUMPS (2A, 2B)

CONTAINMENT SPRAY PUMPS (2A, 2B)

SAFETY INJECTION PUMPS (2A, 2B)

MOTOR-DRIVEN AUX. FEEDWATER PUMPS (2A, 2B)

TURBINE-DRIVEN AUX. FEEDWATER PUMP (NO. 1)

CENTRIFUGAL CHARGING PUMPS (2A, 2B)

COMPONENT COOLING PUMPS (2A1, 2A2, 2B1, 2B2)

RESIDUAL HEAT REMOVAL PUMPS (2A, 2B)

III. The following Safety Class 1, 2, and 3 pumps (See Attachment #1 for specific safety class and available instrumentation) will be tested in accordance with the intent of Subsection IWP, except for the request for relief for the specific requirements determined to be impractical as described below.

A) PUMP: CONTROL AREA CHILLED WATER PUMPS (CRA-P-1, CRA-P-2)

SAFETY CLASS: 3 FUNCTION: To provide chilled water to air handling units supplying control area air conditioning TEST REQUIREMENTS: 1. Measure pump bearing temperature during inservice testing.

2. Annually run pumps until bearing temperatures stabilize.

BASIS FOR RELIEF: There is no instrumentation installed to measure bearing temperature, and no meaningful data can be obtained from bearing housing surface temperature measurements.

ALTERNATE TESTING: The inservice testing of the Control Area Chilled Water Pumps will be in accordance with the intent of Subsection IWP except that bearing temperature will not be monitored and subsequently the pumps will not be run annually until bearing temperature stabilizes.

IV. The follcwing Safety Class 1, 2, and 3 pumps are provided with insufficient instrumentation to perform any meaningful testing in accordance with the intent of Subsection IWP and therefore the following alternate testing methods, as well as requests for relief from compliance with Subsection IWP, are described by the following.

McGUIRE - UNIT 2 I.1-2

l A) PUMP: D/G FUEL OIL TRANSFER PUMPS (2A, 2B)

SAFETY CLASS
3

! l

} FUNCTION: Diesel generator auxiliary support j TEST REQUIREMENT: Test pumps in accordance with Subsection IWP BASIS FOR RELIEF: Pumps contain insufficient instrumentation (See l Attachment #1) to perform any meaningful testing l in accordance with the intent of Subsection IWP.

i ALTERNATE TESTING: Monthly Diesel Generator starting and loading as j required by McGuire Technical Specifications is j sufficient in assessing the hydraulic condition

of the subject auxiliary pumps and demonstrating l j the capability of the individual components to i perform their design function. .

! The mechanical condition of the subject pumps j will be determined from vibration data to be i gathered monthly. Flow will be monitored by l observing level rise in the day tank.

B) PUMP: D/G ROOM SUMP PUMPS (2A2, 2A3, 2B2, 2B3)

SAFETY CLASS
3 if
FUNCTION
Water removal from Diesel Generator rooms j TEST REQUIREMENT: Test pumps in accordance with Subsection IWP 1 '

BASIS FOR RELIEF: -Pumps contain insufficient instrumentation i (See Attachment #1) to perform any meaningful j testing in accordance with Subsection IWP.

ALTERNATE TESTING: Due to the anticipated infrequent normal operation of these pumps, quarterly, each pump j will be verified to be capable of performing their design function of removing water from the

sump at a rate greater than or equal to 419 gpm.

j The time which it takes to pump a known volume

} from the sump is recorded and converted to a j flow rate.

a i

i I McGUIRE - UNIT 2 I.1-3 i

I '

l

. - . , , . - . - . _ . , . . , . , . - .., . . - - - - - . . ~ - ,

SAFETY RELATED CLASS 1, 2 AND 3 PUMPS PROVIDED WITil AN m" EMERGENCY POWER SOURCE > ,o o @

x $ $ ci Y E. U m e - - o 3 5 4 "

% a a 8 e 4 - d "

0 d  ? z 8  %

3  %  % E B x A:

- a 4 3  !? e C

. t u t e 3 . t t t e

% 8. E d a S 8 2 a i PUMPS m H * " A " > '3 "' Q A Nuclear Service Water Pumps (2A, 2B) (RN) 3 QU _ NR X X X X(1) X X X MC-2574-1.1 Containment Spray Pumps (2A, 2B) (NS) 2 QU NR X X X X(1) X(3) X(2) X MC-2563-1.1 Residual IIcat Removal Pumps (2A, 2B) (ND) 2 QU NR X X X X(1) X(3) X(2) X IIC-2561-1.0 Safety Injection Pumps (2A, 28) (NI) 2 QU NR X X X X(1) X X X MC-2562-3.0 M/D Aux. Feedwater Pumps (2A, 2B) (CA) 3 MO NR X X X X(1) X X X MC-2592-1.1 T/D Aux. Feedwater Pump (No. 1) (CA) 3 MO X X X X X(1) X X X MC-2592-1.1 Cent. Charging Pumps (2A, 2B) (NV) 2 QU NR X X NR X(1) X X X MC-2554-3.1 Component Cooling Pumps (2A1, 2A2, 2B1, 2B2) (KC) 3 QU NR X X X X(1) X X X MC-2573-1.0 Control Area Chilled Water Pumps (CRA-P-1,2) (YC) 3 QU NR X X X X(1) X X(4) X MC-1618-1.0 D/G Fuel Oil Transfer Pumps (2A, 2B) (FD) 3 QU NR - -

X X(1) - -

X MC-2609-3.0 D/G Room Sump Pumps (2A2, 2A3, 2B2, 3B3) (WN) 3 QU NR - - - - - -

X MC-2609-7.0 NOTES

1. Vibration to be measured with portable instrumentation (Accuracy 111%).
2. Pump contains no bearings, but is close coupled, therefore motor bearing will be monitored.
3. Pump is close coupled, therefore motor lubricant level will be observed.
4. No instrumentation is installed to measure bearing temperature.

LEGEND X - Instrumentation MO - Monthly QU - Quarterly

- - Instrumentation not available NR - Not required for IWP Compliance ( ) - Note 1.1-4 Mc E - UNIT 2

'l 1

I DUKE POWER COMPANY MCGUIRE NUCLEAR STATION VALVE INSERVICE TESTING PROGRAM

Introduction:

The inservice testing of ASME Code categories A, B, C, and D valves will be tested as required by Section XI, subsection IW, .of the ASME Boiler and

, Pressure Vessel Code 1980 Edition except where specific written relief has been granted by the Commission.

1 i

i r

McGUIRE - UNIT 2 11.1-1 i

.- - . _ _ , - . . - , , , , - . , , , . . . ,-,...a..

TABLE OF ABBREVIATIONS CLASSIFICATION Duke System ANS Valve Designed For Safety Class Code Design Criteria Seismic Loading Class A Class 1, ASME Section III, 1971 Yes 1 B Class 2, ASME Section III, 1971 Yes 2 C Class 3, ASME Section III, 1971 Yes 3 D Class 2, ASME Section III, 1971 No 2 E ANSI B31.1.0 (1967) No NNS F ANSI B31.1.0 (1967) Yes NNS G ANSI B31.1.0 (1967) No -

H Duke Power Company Specifications No -

TEST REQUIREMENTS LT - Leak Test MT - Movement Test Q - Quarterly CS - Cold Shutdown RF - Refueling Outage CT - Cycle and time SP - Setpoint PC - Procedure Check VS - Valve Seating i

l O

McGUIRE - UNIT 2 II.2-1

l DEFINITIONS OF TESTING REQUIREMENTS AND ALTERNATIVES l( '

l Cold Shutdown (CS) Testing will be performed when the unit is in a cold shutdown (Mode 5) whose planned length is of sufficient duration to establish necessary test conditions and to perform the test. In the 4

case of frequent shutdowns, -the testing will not

. be performed more than one per three (3) months.

l' Testing will commence as soon as the cold shut-down condition is achieved but not later than 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after shutdown, and continue until complete or the plant is ready to return to power. Completion of all valve testing is not

. a prerequisite to return to power. Any testing l not completed at one cold shutdown will be per-formed during any subsequent cold shutdowns that may occur before refueling to meet the code-specified testing frequency.

Cycle and Time (CT) Valve will be tested to verify that its stroke time is less than the maximum allowable stroke time specified by McGuire Nuclear Station.

t Leak Test (LT) Valve will be tested to verify that the seat leakage is limited to a specific maximum amount.

l

Movement Test (MT) Valve will be tested to verify that the valve is

! operable and/or the valve moves to the position required to fulfill its purpose. No timing is involved.

Quarterly (Q) Testing will be performed at least once per l

three (3) months.

Refueling Outage (RF) Testing will be performed when the unit is shut down for refueling (Mode 6). Safety valves will be tested periodically per the testing schedule defined in ASME Subsection IWV-3510.

Refueling Outage (RF*) Valve will normally be tested during refueling outages, however, testing is not required more often than once per 2' sonths per Appendix J to 10CFR50.

's( Setpoint (SP) Valve will be tested to verify that it will

', relieve pressure at its specified setpoint.

s McGUIRE - UNIT 2 II.3-1

GENERAL RELIEF TEST REQUIREMENT: Perform trend analyses on category A and B valves as described in IW-3417(a).

l BASIS FOR RELIEF: Trend analyses performed on rapid acting valves does not give reliable indication of valve stroke time deterioration. -

TESTING ALTERNATIVE: Trend analyses will not be performed on valves that normally operate with cycle times of less than 5 seconds. Maintenance will be initiated if valve time exceeds max. limit.

l l

1 l

.z .

0 McGUIRE - UNIT 2 II.4-1

i i

i i

SYSTEM: ANNULUS VENTILATION FLOW DIAGRAMS: MC-2564-1 1

i i

l i

i 4

l l

i i

l l

4 i

1 l

}

} i

! l l

l l

i McGUIRE - UNIT 2 II.5-1 1 - . . _ , _ _ . _ _ _ , _ _ _ , . _ _ ,

n i

l o

t a 2 O

i 5 t

n I e I V

s u

l s u k n r n a A m e

R

e e m v v e i i t s s s s s y a a S P P

$$$0" # ?t$H

$0?e ~jYM T r 3E00?e u$H T L

T L Q MQ rQ t

y D r

o t

C g

e a

C X O B X X X e

l v

a A X X V

3 3 4 4 2

%3t8o 1 1

1 1

G G

J r

e b

m u 1 1 N 1 1 1 g 4 4 4 4 4 n 6 6 6 6 6 i 5 5 5 5 5 w 2 2 2 2 2 a - -

C C

C r C C D M H M M M 2

.yU B B B B B T

_ I N

U r

e -

b m E u R N A I l

e v

0 1

E 1

1 E

A 5

E B

6 E

A 8

E

- UO G

M c

a V V V V V V 2 2 2 2 2

i i

i j

, SYSTEM: AUXILIARY FEEDWATER ,

I l FLOW DIAGRAMS: MC-2592-1.0 j MC-2592-1.1 i

i

)

}

4 l

1 I

l i

e 1

,I i

i i

1 4

1 1

a i

I 1

I McGUIRE - UNIT 2 II.6-1 f

4 i

, .- . _ , _ , . , . _ _ . . . . _ . . . _ . _ . , , _ , - . _ _ - . . _ .. _m- . , --- ~ ,,, . - . ...

r e e d

e t

a w

e i

t e

m g

i t

e m

g e

m e

m i

t m

g i

t m

g 2

6 O

e m n n e i n n i t

i t i i I F t i i t t I t t y e a a e e a a r l r r l l r r a c e e c c e e i y p p y y p p l s c o o c c o o i k .

x r . . . . . .

u a x x x x x x x A m a a a a a a a e m m m m m m m R . . . .

m c c c c c c c e e e e e e e e t s s s s s s s s 0 0 0 y 0 0 0 0 S 6 1 1 6 6 1 1 S S S

$$ae4" Ft$H C C C 3:?& ~dTM X X X X X X T T T T T T T T T T

$E8e?& u$H C M C C M C C C M C y D r

o C

t g

e a

C X X X 0

B X X X X X X X e

l v

a A V

1 1 1 1 1 4 4 7 6 7 a%d?8u G 1 1 1 J K L C 0 C G r_ .

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1 g 2 2 2 2 2 2 2 2 2 2 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 2 2 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M M M M M

Mo C B B B B C C B B B 2 T

I r N U

e b -

m u B, E

N A A A A A A A 0 1 2 6 5 4 6 8 7 4 e 6 6 6 6 6 6 5 5 5 5 v - - - - - - - - - -

G l A A A A A A A A A A c a C C C C C C C C C C M V 2 2 2 2 2 2 2 2 2 2

O O O m u y , y System: Auxiliary Feedwater E $ 6 8 8  !!

1 F Q
  1. E =

m 4 t 4 y y Valve Category y d g U u 0 0 $ $

Valve Number Drawing Number A B C D Remarks 2CA-53 B MC-2592-1.0 H-7 X MT X CS 2CA-52A,B C MC-2592-1.0 K-7 X CT X 60 sec. max. cycle time 2CA-44B C MC-2592-1.0 C-11 X CT X 60 sec. max. cycle time 2CA-45 B MC-2592-1.0 C-9 X MT X CS 2CA-46B B MC-2592-1.0 D-8 X CT 10 sec. max. cycle time

2CA-50B B MC-2592-1.0 G-8 X CT 10 sec. max. cycle time 2CA-49 B MC-2592-1.0 H-8 X MT X CS 2CA-48A,B C MC-2592-1.0 X-8 X CT X 60 sec. max. cycle time 2CA-40B C MC-2592-1.0 G-14 X CT X 60 sec. max. cycle time

. 2CA-41 B MC-2592-1.0 H-14 X MT X CS McGUIRE - UNIT 2 II.6-3

r e

t d

a w

e e

m e

m e

m e

m e

m e

m 4

6 O

e i i i t

i i t

i t I F t t t I

y e e e e e e r l l l l l l a c c c c c c i y y y y y y l s c c c c c c i k x r . .

x x

u a x x a x x a a A m a a a e m m m m m m R , . . .

m c c c c c c e e e e e e e t s s s s s s s

y 0 0 0 0 0 0 S 1 1 6 1 1 1

$jE0#* ?U$H S C

X X

$:aE ~3$M -

jESa?e u$H T T T T T T T T T T C C M C C M C M C M y D

- r o

O g

e C X X X X t

a C

B X X X X X X e

l v

a A V

4 4 4 0 1 1 1 1 3 3 4 5 5 1 E%32O 1 I J K L C B B C C B

_ r e

b m 0 0 0 0 1 1 1 1 1 1 u . . . . . .

N 1 1 1 1 1 1 1 1 1 1 g 2 2 2 2 2 2 2 2 2 2 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 2 2 a - - - - - - - - - -

r C C C C C C C C C C

_ D M M M M M M M M M M B B B C C C C C C C 2

$Mo T

I N

r U e

b -

m u B, E N B B A B A B R U9 2 8 7 6 8 2 1 0 I e 4 3 3 3 1 1 1 1 9 8 v - - - - - - - - - - G l A A A A A A i A A A c a C C C C C C C C C M V 2 2 2 2 2 2 2 2 2

O_ O_ .

5 $

g Ij System: Auxiliary Feedwater 0 0 E 1  : 0

? ? *

% e O E w $

" y Valve Category Ij $ !l 3 0 H

$ Y $

H Valve Number ') Drawing Number ') A B C D k Remarks 2CA-7A C MC-2592-1.1 B-10 X CT 10 sec. cycle time 2CA-15A C MC-2592-1.1 D-3 X CT 10 sec. cycle ti.ne 2CA-86A C MC-2592-1.1 C-14 X CT 10 sec. max. cycle time 2CA-116B C HC-2592-1.1 L-7 X CT 10 sec. max. cycle time 2CA-26 C MC-2592-1.1 I-4 X MT 2CA-27A C MC-2592-1.1 J-5 X CT X 60 sec. max. cycle time 2CA-32 C MC-2592-1.1 I-7 X CT X 60 sec. max. cycle time 2CA-31 C MC-2592-1.1 I-7 X MT 2CA-22 C MC-2592-1.1 I-10 X MT 2CA-20A,B C MC-2592-1.1 I-10 X CT X 60 sec. max. cycle time McGUIRE - UNIT 2 II.6-5

r e

t d

a w

e e

m e

m 6

6 O

e i i I

F t t I

y e e r l l a c c i y y l s c c i k x r . .

u a x x A m a a e m m R

m c c e e e t s s s

y 0 0 S 1 1 F F u> TEE" * $jEH c R R OE?e wjYM X X 3E8n?$ uEH T C

T C

T M

T M

y D r

o g

t C

e a

C X X O

B X X e

l v

a A V

2 2 4 4 1 1 1 1

=BE5$O B B

C G

r e

b m 1 1 1 1 u . . . .

N 1 1 1 1 g 2 2 2 2 n 9 9 9 9 i 5 5 5 5 w 2 2 2 2 a - - - -

r C C C C D M M M M m$U C C C C 2

T I

r N e U b

m -

u C C N 1 2 5 6 E O

6 6 6 6 R e 1 1 1 1 I v - - - - U l A A A A G a C C C C c V 2 2 2 2 M

i i MC-2592-1.0 l O

VALVE: 2CA-60, 2CA-64, 2CA-56, 2CA-52, 2CA-44, 2CA-48, 2CA-40, 2CA-36 CATEGORY: B CLASS: C FUNCTION: Control aux. feedwater flow to S/G's.

TEST REQUIREMENT: Full stroke exercise and stroke time quarterly BASIS FOR RELIEF: Valves can only be timed when aux. feed receives an auto-start signal ALTERNATE TESTING: Valve will be full stroke execised quarterly and timed during ESF testing.

O McGUIRE - UNIT 2 II 6-7

1 l

MC-2592-1.0 l

VALUE: 2CA-61, 2CA-53, 2CA-45, 2CA-37, 2CA-65, 2CA-57, 2CA-49, 2CA-41 CATEGORY: C CLASS: B FUNCTION: Check flow from steam generators to aux. feedwater TEST REQUIREMENT: Full stroke exercise quarterly BASIS FOR RELIEF: Flow through these valves would unnecessarily thermal shock the S/G and feedwater piping.

ALTERNATE TESTING: Valves will be full stroke exercised at cold shutdown.

i O

O McGUIRE - UNIT 2 II.6-8

MC-2592-1.1 VALVE: 2CA-20, 2CA-27, 2CA-32 CATEGORY: B CLASS: C FUNCTION: Maintains minimum flow for Auxiliary Feedwater Pumps.

TEST REQUIREMENT: Full stroke exercise and stroke time quarterly BASIS FOR RELIEF: This valve automatically regulates to maintain the

minimum flow through the pump by monitoring the flow on the suction of the pump. There are not sufficient manual controls on this valve to pennit the desired testing.

These valves will operate during testing of the pump and their operability will be verified then.

ALTERNATE TESTING: These valves will be full stroke exercised quarterly and stroke timed during ESF testing.

O I

l l

l l

McGUIRE - UNIT 2 II.6-9 l

l

MC-2592-1.1 VALVE: 2CA-165, 2CA-166 CATEGORY: C CLASS: C FUNCTION: Prevents backflow from Aux. Feedwater System to Nuclear Service Water System TEST REQUIREMENT: Full stroke exercise quarterly BASIS FOR RELIEF: Flow cannot be put through these valves because this would contaminate the aux, feed system with raw water.

ALTERNATE TESTING: Valves will be verified operable during refueling outages by disassembly.

Ce.

l McGUIRE - UNIT 2 II.6-10 l

1 l

l

l SYSTEM: Boron Recycle FLOW DIAGRAMS: MC-2556-3.0 1

i r

l e

I i

I l

I McGUIRE - UNIT 2 77,7 7

2 O

e c 7 l e 1 c s y 1 c 0 e 1 R <

n s e o k m r r i o a t B m e n R o

i m t e a t l s o y s S I F F

$tE0 # ?j$H R R Oae ~JYM X TT TT m E!a?e

! y$H CL l t L y D r

o t

C g

e a

C X O

B e

v l

a A X X V

5 3

%3T0U G G

_ r e

- b m 0 0 u

N 3 3

_ g 6 6

_ n 5 5 i 5 5 w 2 2 a - -

r C C D  !

1 1

@Mo B B 2 T

I N

r U e

b -

m u B E N 0 2 l

e v

6 2

H 6

2 B

- RO I

U G

c a N N M V 2 2

MC-2556-3.0 VALVE: 2NB-262 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal. ,

ALTERNATE TESTING: Leak rate performed every 24 months will verify valve closure.

4 O

f I

l l

McGUIRE - UNIT 2 II.7-3 l

l .

1 I

i

]

SYSTEM: BREATHING AIR I

FLOW DIAGRAMS: MC-2605-3.1 i

1 l

i i

i T

l i,

4 l

l C

1

/

i l

i McGUIRE - UNIT 2 II.8-1 O

_ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ . _ _ - _ . , . _ _ _ . _ _ _ _ . . _ _ _ , , . . _ _ . . _ _ _ , . _ _ _ _ _ _ . , _ _ _ _ _ _ _ _ . _ _ , . _ _ .._._..s

r .

2 8

O i c A e 1 s 1 g

n 5 i 1 h

t s e a k m e r i r a t B m e n R o

i m t e a t l s o y s S I F F

$t$0"2 ?t$H R R 0 ?e ~jYM X

$E90?e aEH T T T T CQL MQL y D r

o t

C g

e a

C X O

B e

l v

a A X X V

2 4

" 3? ou - -

G E r

e b

m 1 1 u . .

N 3 3 g 5 5 n 0 0 i 6 6 w 2 2 a - -

r C C D M M

$MU B B 2 T

I r N U

e b -

m u E N B R 0

l e

v a

9 4

B V

5 B

V

- UO I

G c

M V 2 2

-_._ _ _ _ .__ _ ~ _ ._ -. __ ._ ...- _

MC-2605-3.1 l

VALVE
2VB-50 l

. CATEGORY: A, C i CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per 3 months.

BASIS FOR RELIEF: The system design does not provide any indication for  !

verifying valve closure upon flow reversal.

t ALTERNATE TESTING: Leak rate test performed every 24 months will verify valve closure.

I 1

l

]

i i

1 1

\

l l

McGUIRE UNIT-2 II.8-3

,w-w guy +. - , yywe e,- y w,+gg-, ,,--

SYSTEM: CHEMICAL & VOLUME CONTROL SYSTEM FLOW DIAGRAMS: MC-2554-1.1 1

MC-2554-1.2 MC-2554-1.3 MC-2554-2.0 MC-2554-3.0 MC-2554-3.1 O

McGUIRE - UNIT 2

-II.9-1

$ lystem: Chemical anel Volume Control E 0 8

e a a s

%  ? & B S a ~ #8 E  ?, Valve Category u 3 Y$

d u

8 $ T E" Valve Number Drawing Number A B C D " " H# Remarks 2NV-94A,C B MC-2554-1.1 J-13 X CT X 10 sec. max. cycle time 2NV-95B B MC-2554-1.1 11-13 X CT X 10 sec. max. cycle time 2NV-12 B MC-2554-1.2 F-11 X MT 2NV-21A A MC-2554-1.2 E-3 X CT 60 sec. max. cycle time 2NV-22 A MC-2554-1.2 C-3 X MT 2NV-457A B MC-2554-1.2 I-7 X CT Isolation time 515 sec.

2NV-458A B MC-2554-1.2 J-7 X CT Isolation time 515 sec.

2NV-459A B MC-2554-1.2 K-7 X CT Isolation time $15 sec.

2NV-7B B MC-2554-1.2 J-10 X CT X CS 10 sec. max. cycle time 2NV-1A A MC-2554-1.2 C-5 X CT X CS 10 sec. max. cycle time 2NV-2A A MC-2554-1.2 D-5 X CT X CS 10 sec. max. cycle time i

II.9-2 e e IRE - UNIT 2 M6c

IG i

(/ (-

U

$ System: Chemical and Volume Control E

E a #

$ E m U R & ~% W8 E  ? Valve Category u $$ $$

M o

8 u H E YE

"" H E"

Valve Number Drawing Number A B C D Remarks 2NV-24B A MC-2554-1.2 D-6 X CT 60 sec. max, cycle time 2NV-1013 E MC-2554-1.3 F-12 X CT 30 sec. max. cycle time 2NV-1012C E MC-2554-1.3 F-12 X CT 30 sec. max. cycle time 2NV-844 E MC-2554-1.3 F-5 X Kr 2NV-1007 B MC-2554-1.3 F-13 X MT X CS 2NV-1008 B MC-2554-1.3 F-13 X MT X CS 2NV-1009 -B MC-2554-1.3 F-14 X Kr X CS 2NV-1010 B MC-2554-1.3 F-14 X MT X CS 4

McCUIRE - UNIT 2 II.9-2a

l e e

~

t o

r n

o e e m

e e i

t m

g i

t m

g 3

9 O

C m m m i i i i n n e t t t t i t

i t

I I

m u e e e e a a l l l l l r r o c c c c e e V y y y y p p s c c c c o o d k n r .

x a a x x x x x m a a a a a a l e m m m m m m a R .

c . . . .

c i c c c c c m e e e e e e e s s s s s s h

C 5 5 0 0 0 0 1 1 1 1 1 1 m

e m3%6 add S S S t F S s

y wduEH R C C C C S

aEmE" X X X X X Y Y*

T TT TT T T T T

  • eE01s* uEH C LC LM C C C C y D r

o t

C g

e a

C X O

B X X X X X e

v l

a A X X V

0 1 8 1 8 7 8 9 mB35uSo - - - - - - -

F F F B B K K r

e b

m 3 3 3 0 0 0 0 u

N 1 1 1 2 2 3 3 g 4 4 4 4 4 4 4 n 5 5 5 5 5 5 5 i 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 a - - - - - - -

r C C C C C C C D M M M M M M M mmMo B B B B B B B 2

T I

r N e U b C, C, m -

_ u A A 2 A B A B E

_ N 2 9 0 1 2 4 5 4 4 4 bR 4 4 0 4 e 8 8 1 1 1 2 2 v - - - - - - - U G

l V V V V V V V a N N N N N N N c V 2 2 2 2 2 2 2 M

.- - . -. - .. . . _ . _ - - - - _ - _ . - - - ~ . .-_ -

O v

O v

5 System: Chemical and Volume Control E

9 0 a #

N 0 m $

S a ~# Fa E  ? Valve Category y $g jg N

o u E E H

YE Ed NN H< Remarks Valve Number Drawing Number A B C D 2NV-222B B MC-2554-3.1 I-1 X CT X CS 10 sec. max. cycle time 2NV-221A B MC-2554-3.1 11 - 1 X CT X CS 10 sec. max. cycle time 2NV-223 B HC-2554-3.1 I-2 X MT X 2NV-227 B MC-2554-3.1 E-6 X MT 2NV-233 B MC-2554-3.1 E-10 X MT 2NV-231 B MC-2554-3.1 F-10 X MT X 2NV-225 B MC-2554-3.1 F-5 X MT X McGUIRE - UNIT 2 '

II.9-4

MC-2554-1.1 VALVE: 2NV-94A,C,2NV-95B CATEGORY: B CLASS: B FUNCTION: a) Provide containment isolation b) Reactcr coolant pump seal water discharge line.

TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: Closure of one of these valves during unit operation

! would inhibit normal seal water flow across the reactor coolant pump number 1 seal. This action could result in damage to the reactor coolant pump seals or the pumps themselves.

ALTERNATE TESTING: Valves will be cycled and timed during cold shutdowns.

O l

O McGUIRE - UNIT 2 II.9-5

MC-2554-1.2 VALVE: 2NV-7B I

l CATEGORY: B CLASS: B

FUNCTION
Letdown containment isolation. -

TEST REQUIREMENT: Full stroke exercise and stroke time quarterly BASIS FOR RELIEF: Failure of this valve in closed position could result in loss of PZR level control and could result in a plant shutdown.

ALTERNATE TESTING: Valve will be exercised and times at cold shutdown.

J c

O i

- hs

.~c.;y McGUIRE - UNIT 2 II.9-6 I

MC-2554-1.2  ;

VALVE: 2NV-1A, 2NV-2A CATEGORY: B CLASS: A FUNCTION: Isolate regenerative heat exchanger TEST REQUIREMENT: Cycle and time every three months BASIS FOR RELIEF: Failure of this valve in closed position could result in loss of pressurizer level control ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown L-

l MC-2554-1.3 1

VALVE: 2NV-1002 1
i j CATEGORY
A, C l t

i i CLASS: B j

4 l FUNCTION: Provides containment isolation i

1 j TEST REQUIREMENT: Full stroke exercise quarterly j i

j BASIS FOR RELIEF: There is no indication of valve closure.

I

! ALTERNATE TESTING: Valve will be verified closed by leak rate test performed in accordance with Appendix J.

l t

i a

i j

a i

i 1

)

i l

4 ,

a 1

i 1

4 1

2 i

2 l

i i

i 1

i i

i i

l McGUIRE - UNIT 2 II.9-7 l

t I

_ , , ~ . , _ - , . . - . . . - , - - . ~ , - . - . . . ~ , . , _ , _ - - . . - . . . - . ~ , . . . . - , . . . - . .

1 1

MC-2554-1.3 x

VALVE: 2 NV-1007, 2 NV-1008, 2 NV-1009, 2 NV-1010 0

CATEGORY: C CLASS: B FUNCTION: Opens on flow from standby makeup pump to reactor coolant pump seals.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: These valves cannot be full or partial stroked during power operation as this would increase boron inventory in the RCS and could result in a unit shutdown.

l ALTERNATE TESTING: Valves will be full stroked at cold shutdown.

L 1

O i

l l

l O

McGUIRE - UNIT 2 II.9-7a

MC-2554-2.0 f

VALVE: 2NV-141A, 2NV-142B CATEGORY: B CLASS: B FUNCTION: Isolates volume control tank upon receipt of a safety injection signal.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Closure of one of these valves would isolate the suction for the charging pumps. This action could result in damage to the charging pumps. Seal water for the reactor coolant pumps would also be inhibited. This is undesirable in that damage could be done to the seals. .

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

G O

McGUIRE - UNIT 2 II.9-8

i l

l j 1

MC- 2554-3.0

( '

l l VALVE: 2NV-244A, 2NV-245B l

CATEGORY: B l

CLASS: B FUNCTION: Isolates charging to the Reactor Coolant System upon receipt of a safety injection signal.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: If one of these valves were to fail in the closed position during testing, normal and alternate charging would be lost. This could result in a loss of pressurizer level control and could result in a plant trip.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

O 1

1 r

l49 McGUIRE - UNIT 2 II,9_9

i MC- 2554-3.1

!.CO VALVE: 2NV-225, 2NV-231 CATEGORY: C CLASS: B i

FUNCTION: Opens on flow from the Centrifugal Charging Pump (s).

TEST REQUIREMENT: Verify proper valve movement every three months.

BASIS FOR RELIEF: Valve cannot be full or partial stroke exercised during power operation or cold shutdown because this would result in an increase in the RCS boron

! inventory and could result in a plant shutdown.

i Full stroke exercising during cold shutdown could I result in a low temp. overpressurization of the RCS.

ALTERNATE TESTING: Valve will be full stroked during refueling.

t I

l

()

1 l

}

i l

l 1

I l

J i

4 1

I 1

McGUIRE - UNIT 2 11.9-10 j l

l 1

MC-2554-3.I VALVE: 2NV-223 CATEGORY: C CLASS: B FUNCTION: Opens on flow alignment from FWST -

TEST REQUIREMENT: Verify proper valve movement every three months.

BASIS FOR RELIEF: Testing of this valve requires opening ,aNV-221A or 2NV-222B. Failure of one of these valves in the open position aligns the WST to the suction of the charging pumps with no means of isolating the flow path. This would result in an increase in boron inventory in the RCS and could result in a plant shatdown. Full stroke exercising at cold shutdown could result in a low temperature overpressurization.

ALTERNATE TESTING: Valve will be partial stroked during cold shutdowns and full stroked during refueling.

O Ot O

F:-

McGUIRE - UNIT 2 I1 9-11

i e MC-2554-3.1 5

l VALVE: 2NV-221A, 2NV-222B l CATEGORY: B 1

, CLASS: B FUNCTION: Aligns fueling water storage tank (FWST) to the suction 1 of the centrifugal charging pumps upon receipt of a safety i injection signal.

I~

TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: If one of these were to fail in the open position during testing, the FWST would be aligned to the suction of the charging pumps. This would result in an increase in RCS j Boron inventory and could result in a plant shutdown.

i ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

)

]

1 i

l J

j J

i

)

i i

I a

i i

i i

< s i

~

l l

McGUIRE - UNIT 2 II.9-12 l

1 J

1 l

1

'l SYSTEM: COMPONENT COOLING l  !

l FLOW DIAGRAMS: MC-2573-1.0 i r

j MC-2573-1.1 )

MC-2573-3.1 l MC-2573-4.0 1

}

i I

i i,

3 i

1 I

i l

i

=

b I

1 i

i l

i l

i 1

1 1

i J

i 4

1 l

'1 1

i I

i i

i McGUIRE - UNIT 2 II.10-1

i l

g n

e e e e e e 2

0

- O o m m m m m m 1 o i i .

i i i i t t t t t I C t I t e e e e e e n l l l l l c

l c

e c c c c y y n y y y y o s c c c c c c p k . .

m r . . . .

o a x x x x x x C m a a a a a a e m m m m m m R . . . . .

m c c c c c c e e e e e e e t s s s s s s s 0 0 y 0 0 0 0 1 1 S 6 6 5 5 m3 hee w4g I0g 1g T T T T T T T T T T 0 aN1E" g C C C C M M M M C C y D r

o O

g e C X X X X t

a C

B X X X X X X e

v l

a A V

1 1 0 7 8 7 8 4 4 1 1 5 1 m3Eag - - - - - - - - - -

C C C C F F F F J J r

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1

1 g 3 3 3 3 3 3 3 3 3 3 n 7 7 7 7 7 7 7 7 5

7 5

7 5

i 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 2 2 a - - - - - - - - -

C r C C C C C C C C C D M M M M M M M M H M m C C C C C C C C C C 2 T

_ I N

r U e

b -

m u B E

N B A l

e v

A 1

C B

2 C

A 3

C 8

1 C

5 C

8 C

1 1

C 4

1 C

5 1

C 4

5 C

- RO I

U G

c a K K K K K K K K K K M V 2 2 2 2 _ 2 2 2 2 2 2

O_ O_

$ j System: Component Cooling 0

6 8 E f.

E d  ? A

%  ? e R e ~  ?

l  ? Valve Category y j j M o E Y E i i- Val.ve Number o Drawing Number u A B C D H M H Remarks 1

i 2KC-50A C MC-2573-1.0 K-7 X CT 60 sec. max. cycle time i

2KC-230A C' MC-2573-1.0 K-7 X CT 40 sec. max, cycle time

]

2KC-53B C MC-2573-1.0 K-8 X CT 60 sec. max. cycle time f

I

) 2KC-228B 'C MC-2573-1.0 K-8 X CT 40 sec. max. cycle time i

4 i

! 2KC-56A C MC-2573-1.1 E-2 X CT 60 sec. max. cycle time 2KC-57A C MC-2573-1.1 D-6 X CT 60 sec. max. cycle time 2KC-81B .C MC-2573-1.1 F-13 X CT 60 sec. max. cycle time 2KC-82B C MC-2573-1.1 D-9 X CT 60 sec. max. cycle time i

McCUIRE - UNIT 2 11.10-3

, - ,. , . - e, - - - . ,w .,r .--,-, e. -+ - - - ~ ~ ,

o System: Component Cooling

$ $ 6 m 0 $ 0 3 1 *

? 4

$ l w 4 "

% 3u

@ g Valve Category g 3 Valve Number Drawing Number A 1 B C D __

Remarks 2KC-424B B MC-2573-3.1 L-4 X LT X CS Isolation time $40 sec.

CT 2KC-425A B MC-2573-3.1 L-6 X LT X CS Isolation time $40 sec.

CT 2KC-279 B MC-2573-3.1 K-4 X X LT X RF MT 2KC-315B B MC-2573-3.1 L-13 X CT Isolation time 530 sec.

2KC-305B B MC-2573-3.1 D-14 X CT Isolation time 530 sec.

2KC-340 B MC-2573-3.1 E-12 X X LT X RF HT 2KC-338B B MC-2573-3.1 D-12 X LT X CS Isolation time $40 sec.

CT 2KC-320A B MC-2573-3.1 C-10 X LT X CS Isolation time $15 sec.

CT II.10-4 McGUIRE - UNIT 2 s O O O

C O O 0 Y System: Component Cooling E O E S $ $

$ a  ? y

  1. ? a 3 a ~ E E  ? Valve Category u O U

'M o E Y $

Valve Number U Drawing Number o A B C D H " H Remarks 2KC-322 B HC-2573-3.1 C-9 X X LT X RF MT 2KC-280 B MC-2573-3.1 D-1 X X LT X RF MT

, 2KC-332B B HC-2573-3.1 D-1 X LT X CS Isolation time 515 sec.

CT 4

2KC-333A B MC-2573-3.1 G-1 X LT X CS Isolation time 515 sec.

CT 1

l 1

2KC-47 B HC-2573-4.0 L-7 X X LT X RF MT 2KC-429B B MC-2573-4.0 K-7 X LT Isolation time $15 sec.

4 CT i

i 2KC-430A B HC-2573-4.0 K-8 X LT Isolation tinae 515 sec.

] CT II.10-5 McGUIRE - UNIT 2

1 MC-2573-3.1 i

1 VALVE: 2KC-424B, 2KC-425A l

CATEGORY: A CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit the normal flow path from the reactor coolant pump motor coolers. This action could result in damage to the pump.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

O O

McGUIRE - UNIT 2 II.10-6

. . -~ - . .- . .

E

.1 MC-2573-3.1 1

l i

O l' :

VALVE: 2KC-280 i

! CATEGORY: A, C 1

1 CLASS: B i

l FUNCTION: Provides containment isolation and prevents over-l pressurization of line between 2KC-332B and 2KC-333A.

i l TEST REQUIREMENT: Verify proper valve movement.

a BASIS FOR RELIEF: This valve cannot be practically tested during operation due to the design of the system.

! ALTERNATE TESTING: Valve will be verified closed by leak test performed i in accordance with Appendix J.

.I

?

1 i

l i

1 4

)

i 4

)

i i

I l 1

1

\

1 i l 2 i 6

i r

l McGUIRE - UNIT 2 II.10-7

1 l

1 l

l MC-2573-3.1 VALVE: 2KC-322 CATEGORY: A, C CLASS: B FUNCTION: Provides Containment Isolation.

TEST REQUIREMENT: Verify valve seats on flow reversal.

BASIS FOR RELIEF: Testing of this valve during operation is prohibited due to the system design.

ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.

O l

l O

l McGUIRE - UNIT 2 II.10-8 i

l

i MC-2573-3.1 VALVE: 2KC-279 i

l CATEGORY: A, C a

i j CLASS: B 1

{ FUNCTION: Provides containment isolation and prevents over-j pressurization of line between 2KC-424B and 2KC-425A.

1 4

j TEST REQUIREMENT: Verify valve seats on flow out of containment.

1 l BASIS FOR RELIEF: The system design does not provide a means of verifying j valve closure upon flow reversal.

i

ALTERNATE TESTING
Valve will be verified shut by leak test performed j in accordance with Appendix J.

i 9

't 1

i 1

i i

i l

i b

i 1

i l McGUIRE - UNIT 2 II.10-9 l

l r

MC-2573-3.1 VALVE: 2KC-340 CATEGORY: A, C CLASS: B FUNCTION: Provide Containment Isolation.

TEST REQUIREMENT: Verify valve seats on flow reversal cace every three months.

BASIS FOR RELIEF: The system design does not provide a means of verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified closed by leak test performed in accordance with Appendix J.

O 1

l l

O McGUIRE - UNIT 2 11,10 10

.- .. . - = . - . .

l' MC-2573-3.1 1

1 VALVE: 2KC-338B )

CATEGORY: A ,

CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit flow to the reactor vessel support j coolers. This action could result in damage to the j reactor vessel.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

1 l

I l

1 I

l l

l l

l l

McGUIRE - UNIT 2 II.10-11

MC-2573-3.1 VALVE: 2KC-332B, 2KC-333A CATEGORY: A CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of one of these valves in the closed position during testing would inhibit the flow path through the reactor coolant drain tank heat exchanger. No alternate flow path is available, which would force unit shutdown until the valve is repaired. Steam would be released to the RCDT which would become overpressurized.

ALTERNATE TESTING: Valves will be cycled and timed during cold shutdowns.

O l

l O

l l McGUIRE - UNIT 2 II.10-12 l

- = .. - . - - - - - . .- - ..._ - _ . . - . . _ _ . . ._ _. _. -

MC-2573-3.1 i

l VALVE: s 2KC-320A l CATEGORY: A CLASS: B l

FUNCTION: Provides containment isolation.

i TEST REQUIREMENT: Cycle and time every three months.

l BASIS FOR RELIEF: Failure of this valve in the closed position during

testing would isolate flow to the reactor coolant drain -

j tank heat exchanger. This failure would require unit i shutdown until the valve could be repaired due to over-

pressurization of the RCDT.  ;

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

I i

i

.i

['

l 4

< A

, g 4 1 G

r-McGUIRE - UNIT 2 II.10-13

MC-2573-4.0 l

VALVE: 2KC-47 -

CATEGORY: A, C CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Verify valve seats on flow out of containment.

BASIS FOR RELIEF: This valve cannot be practically tested during unit operation due to system design. No instrumentation is installed which can monitor any flow past the check valve.

AL~ERNATE TESTING: Valve will be verified shut by leak test performed in accordance with Appendix J.

O O

McGUIRE - UNIT 2 II.10-14

i a

1 j SYSTEM: CONTAINMENT AIR REIIASE AND ADDITION i

FLOW DIAGRAMS: MC-2585-1.0 i

e i

i i

l 4

I l

i l

4 4

i i

a i

i i

F j

i 4

i 1

i McGUIRE - UNIT 2 II.11-1

)

i l

, , , .c-.-,,-, .__.....,,,. ,,,... ~ , , ,- , , _ . , ,,,,,_-, . .,.

l 1)l\lllll 1l 1Il n

o i

t i

d d . . . .

2 1

1

- O A c c c c .

e e e e I d s s s s I n

a 3 3 3 3 5 5 5 5 e

s s e e e e a k m m m m e r i i i i l a t t t t e m R e n n n n R o o o o r i i i i i t t t t A a a a a l l l l t o o o o n s s s s e I I I I m

n i

a # net" * * *

  • t P F F F F n

o Et

  • R R R R C

m % 8E"

waT#

m e

t s

y m%88al" T CQL T T C4L T T CQ T

CQL T

S ,l" y D r

o t

C g

e a

C O

B e

v l

a A X X X X v

4 6 6 3

$%3?8u - - - -

J J E E r

e b

m 0 0 0 0 u

N 1 1 1 1 g 5 5 5 5 n 8 8 8 8 i 5 5 5 5 w 2 2 2 2 a - - - -

r C C C C D 1 t

I P

t 1

t B B B B 2 "o4u T

I r N e U b -

m u E N

l v

a e

A 1

Q V

B 2

Q V

B 5

Q V

6 A

Q V

- RO I

U G

c V 2 2 2 2 M

!\llll llllll

j 1

SYSTEM: CONTAINMENT AIR RETURN EXCHANGE AND HYDROGEN SKIMMER i f FLOW DIAGRAMS: MC-2557-1.0 i,

i a

4 i

4 i

I

]

1 i

i I

l ll j

i 1

4 1

i 1

i e

.t i

l 4

?

i I

l 1

i i

i 1

i l

)

1 1

i.

4 3 McGUIRE - UNIT 2 II.12-1 f

, y -. . -

c--- - , - - -- .-- , , - - - - - - - . - - , .- , . , - . - , , - - -

System: Containment Air Return Exchange and liydrogen Skimmer m $ e 3 5 3 3 8 n w"

$ Valve Category a h M

o 8 EE YE H* ** H<

Ed Valve Number Drawing Number A B C D Remarks 2VX-34 B MC-2557-1.0 K-12 X LT Passive 2VX-40 B MC-2557-1.0 K-3 X LT Passive 2VX-30 B MC-2557-1.0 J-3 X X HT X RF Q

LT 2VX-31A B MC-2557-1.0 J-13 X CT Isolation time 15 sec.

Q LT 2VX-33B B MC-2557-1.0 J-12 X CT Isolation time 55 sec.

Q LT 2VX-1A B MC-2557-1.0 I-2 X CT 60 sec. max. operating time Q

2VX-2B B MC-2557-1.0 I-12 X CT 60 sec. max. operating time Q

II.12-2 McG5E-UNIT 2 e e

MC-2557-1.0 O  ;

VALVE: 2VX-30 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

i TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for i verifying valve closure upon flow reversal.

ALTERNATE TESTING: Valve will be verified shut by leak test performed in accordance with Appendix J.

O 1

I i

O McGUIRE - UNIT 2 II.12-3~

. _ . _ ~ . _ _ _ . , _ . _ . . , _ _ . - _ .

l SYSTEM: CONTAINMENT PURGE VENTILATION l

FLOW DIAGRAMS: MC-2576-1.0 l

1 l

1 i

i 1

i i

i I

l l McGUIRE - UNIT 2 II.13-1 l

n o

i t

l i

a 2

3 1

- O t c c c c c c .

n e e e e e e I e s s s s s s I V 3 3 3 3 3 3 e 5 $ $ $ $ $

g r s e e e e e e u k m m m m m m P r i i i i i i a t t t t t t t m n n e n n n n n e R o o o o o o i i i i m i i n t t t t t t i a a a a a a a l l l l l l o

t o o o o o n s s s s s s o I I I I I I C

sta$d4 * * * * *
  • F F m

e E$EH F R

F R

F R

F R R R t

s . " $E" y

S X X X X X X

$. Y" T T T T T T T T T T T T

" E$a?a uEH CQL CQL CQL CQL CQL CQL y D r

o t

C g

e a

C O

B e

l v

a A X X X X X X V

3 4 3 4 3 4 m3aa$O - - - - - -

I I 1 I D D r

e b

m 0 0 0 0 0 0 u

N 1 1 1 1 1 1 g 6 6 6 6 6 6 n 7 7 7 7 7 7 i 5 5 5 5 5 5 w 2 2 2 2 2 2 a - - - - - -

r C C C C C C D M  !

? M M M M B B B B B emu B 2

_ T I

N r U e

b -

m u E N R l

e v

a B

1 P

V A

2 P

V B

3 P

V 4

A P

V 6

B P

V A

7 P

V

- IO U

G M

c V 2 2 2 2 2 2

i System: Containment Purge Ventilation

. n e

5 3 8 8 B w%

. e a %: SEe g g Valve Category ug g a o oe ee e Valve Number Drawing Number " A B C D H" "" Hq Remarks 2VP-8B B MC-2576-1.0 C-3 X CT X RF* Isolation time 53 sec.

Q LT 2VP-9A B MC-2576- 1. 0 C-4 X CT X RF* Isolation time 53 sec.

Q LT 2VP-10A B MC-2576-1.0 G-11 X CT X RF* Isolation time 53 sec.

Q LT 1

2VP-11B B MC-2576-1.0 G-12 X CT X RF* Isolation time 53 sec.

Q LT

2VP-12A B MC-2576-1.0 F-11 X CT X RF* Isolation time 53 sec.

j 9 j LT I

2VP-13B B HC-2576-1.0 F-12 X CT X RF* Isolation time 53 sec.  ;

Q LT l

McGUIRE - UNIT 2 11.13-3

System: Containment Purge Ventilation m 0 m 3 8 3 E O E mU m

m Y

u Valve Category uo U YE d8 y a ue d

o u 8 EE HM YE

"" H4 Ed Valve Number Drawing Number -A B C D Remarks 2VP-15A B  ?!C-2576-1.0 E-11 X CT X RF* Isolation time 53 sec.

Q LT 2VP-16B B t1C-2576-1.0 E-12 X CT X RF* Isolation time 53 sec.

Q LT 2VP-17A B t!C-2576-1.0 D-11 X CT X RF* Isolation time 53 sec.

Q LT 2VP-18B B MC-2576-1.0 D-12 X CT X RF* Isolation time 53 sec.

Q LT 2VP-19A B 11C-2576-1.0 C-11 X CT X RF* Isolation time 53 sec.

Q LT 2VP-20B B t1C-2576-1.0 C-12 X CT X RF* Isolation time 53 sec.

Q LT McGUIRE - UNIT 2 II.13-4 O O O

MC-2576-1.0 VALVES: 2VP-1B, 2VP-2A, 2VP-3B, 2VP-4A, 2VP-6B, 2VP-7A, 2VP-8B, 2VP-9A, 2VP-10A, 2VP-11B, 2VP-12A, 2VP-13B, 2VP-15A, 2VP-16B, 2VP-17A, 2VP-18B, 2VP-19A, 2VP-20B CATEGORY: A CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Cycle and time valves every three months.

BASIS FOR RELIEF: Technical Specification 4.6.3.4 requires a leak rate test on these valves whenever they are cycled. In addition, Technical Specification 4.6.1.9 places severe restrictions on the operational time and alignment permitted for this system during normal operation. 2VP-1, 2VP-2, 2VP-3, and 2VP-4 may be opened- for only 90 hours0.00104 days <br />0.025 hours <br />1.488095e-4 weeks <br />3.4245e-5 months <br /> a year at power.

The rest of the VP valves may not be opened at all during power operation.

ALTERNATE TESTING: Valves will be timed whenever the system is operated or whenever the valves are cycled, and the elapsed time since the previous test has been three months or greater.

O Q:.-}>

McGUIRE - UNIT 2 II.13-5

'I i

i SYSTEM: CONTAINMENT SPRAY l

FLOW DIAGRAMS: MC-2563-1.0 1

i.

1 1

I, 1

1, i

t i

i l

4 i

i b

i l

l 1

i i l

l McGUIRE - UNIT 2 11,14 1

$ j System: Containment Spray 5 0 $

0

0 ? "

A

%  ? 8 S & m a"

$ 2 Valve Category u $ j M 8 u

0 H

Y M

H U Drawing Number A B C D Remarks Valve Number _

2NS-43A B t1C-2563-1.0 K-5 X CT 10 sec. max. cycle time 2NS-46 B MC-2563-1.0 K-3 X MT X RF 2NS-38B B MC-25643-1.0 J-5 X CT 10 sec. max cycle time 2NS-41 B MC-2563-1.0 J-3 X MT X RF 2NS-18A B MC-2563-1.0 G-13 X CT 30 sec. max. cycle time 2NS-20A B MC-2563-1.0 F-13 X CT 30 sec. max. cycle time 2NS-21 B MC-2563-1.0 F-12 X MT X RF 2NS-32A B MC-2563-1.0 11 - 4 X CT 10 sec. max. cycle time 2NS-29A B MC-2563-1.0 F-4 X CT 10 sec. max. cycle time 2NS-30 B MC-2563-1.0 F-2 X MT X RF II.14-2 Me'IIRE - UNIT 2 o e

O O E

E O E m 0 $ $

3 4  ?  %

E  ? a m 4 a -  ?

$ $ Valve Category u $ U U O E Y $

Valve Number Drawing Number A B C D H " H Remarks 2NS-33 B MC-2563-1.0 11 - 2 X MT X RF 2NS-4 B MC-2563-1.0 B-12 X MT X RF 2NS-3B B MC-2563-1.0 B-13 X CT 30 sec. max. cycle time 2NS-1B B MC-2563-1.0 C-13 X CT 30 sec. max. cycle time 2NS-15B B MC-2563-1.0 D-4 X CT 10 sec. max. cycle time 2NS-16 B MC-2563-1.0 D-2 X MT X RF 2NS-12B B MC-2563-1.0 C-4 X CT 10 sec. max. cycle time 2NS-13 B MC-2563-1.0 B-2 X MT X RF McGUIRE - UNIT 2 11.14-3

MC-2563-1.0 VALVE: 2NS-30, 2NS-33, 2NS-16, 2NS-13, 2NS-46, 2NS-41 CATEGORY: C CLASS: B FUNCTION: Open on flow from the Containment Spray Pumps.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS ?0R RELIEF: The system design has not provided a means for verifying that the valve opens when flow is initiated for the NS pumps.

ALTERNATE TESTING: These valves will be tested during refueling outages by disassembly.

O l

l l

l McGUIRE - UNIT 2 II.14-4

HC-2563-1.0 i O'

VALVE: 2NS-21, 2NS-4 CATEGORY: C 1

CLASS: B FUNCTION: Prevent flow path from the Containment Recirculation Sump to the FWST.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: Full stroke exercising with flow would require spraying the reactor building.

ALTERNATE TESTING: Valves will be full stroked at refueling by disassembly.

Valves will be partial stroked quarterly.

1 o

O McGUIRE - UNIT 2 II.14-5

! l 1

SYSTEM: CONTAINMENT VENTILATION COOLING WATER l FLOW DIAGRAMS: MC-2604-3.0 1

1.

1 4

I i

I 1

1 4

1 1

l l

1 i

i i

i i

}

}

i 4

i i

h l

i McGUIRE - UNIT 2 II.15-1

$ System: Containment Ventilation

@ Cooling Water 0

a d #

N S m U S a ~" #2

$ 2 Vsilve Category u 3$ $$

M o u 8

H

$ YE "N

H Valve Number Drawing Number A B C D Remarks 2RV-79A B MC-2604-3.0 K-7 X CT RF* Isolation time $30 sec.

LT 2RV-80B B MC-2604-3.0 K-5 X CT RF* Isolation time $20 sec.

LT 2RV-32A B MC-2604-3.0 K-10 X CT CS Isolation time <60 sec.

LT X RP 2RV-33B B MC-2604-3.0 K-12 X CT CS Isolation time <60 sec.

~

LT X RF*

2RV-130A B MC-2604-3.0 J-12 X X MT X RF*

LT 2RV-77B B MC-2604-3.0 C-10 X CT CS Isolation time 560 sec.

LT X RF*

2RV-76A B MC-2604-3.0 C-12 X CT CS Isolation time 530 sec.

LT X RF*

McGUIRE - UNIT 2 II.15-2 O O O

._ _ ._______.-__._.._m_ . . . . . _ _ . . _ _ _ . _ _ _ _ . _ . _ _ _ . _ _ _ _ _ _ _ _ . . _ _ . _ _ _ _ _ . . _ _ _ _ . _ . . _ _ . _ -.

O O 3 System: Containment Ventilation

@ Cooling Water 0

. u .

0 Y M e a m a

? 5 mN $*

E  ? Valve Category u $$ th M

o o 0 $

H YE

"" HN Valve Number Drawing Number A B C D Remarks 2RV-126 B MC-2604-3.0 B-12 X X MT X RF*

LT 2RV-102B B MC-2604-3.0 C-7 X CT Isolation time $30 sec.

LT 2RV-101A B MC-2604-3.0 C-5 X CT Isolation time $30 sec.

LT i

2RV-151A C MC-2604-3.1 E-13 X CT 60 sec. max. cycle time 2RV-152B C MC-2604-3.1 E-13 X CT 60 sec. max. cycle time a

4 9

i McGUIRE - UNIT 2 II.15-3 i

MC-2604 3.0 VALVE: 2RV-77B, 2RV-76A, 2RV-32A, 2RV-33B CATEGORY: A CLASS: B FUNCTION: Provide containment isolation. -

TEST REQUIREMENT: Cycle and time valve once per quarter.

BASIS FOR RELIEF: Failure of one of these valves in the closed position would inhibit cooling flow to the containment. This would result in a steep rise in lower containment temperature which could. exceed tech. spec. limits and cause a plant shutdown.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

Cs t

[.

l McGUIRE - UNIT 2 II.15-4

=. _ - _-_ - - _. - - . - .. .. .

i.

1 i

i i

j MC-2604-3.0 i

l VALVE: 2RV-130, 2RV-126 i

CATEGORY: A, C i CLASS: B 4

{ FUNCTION: Provide containment isolation.

1 I TEST REQUIREMENT: Verify proper valve movement once per three months.

4 t

I BASIS FOR RELIEF: The system design does not provide any indications for i verifying valve closure upon flow reversal.

1 1 ALTERNATE TESTING: Valve will be verified closed by leak test performed

in accordance with Appendix J.

I I

1 i

i i

I

)

1 1

e l

f, l

1 i

i

)

}

B i

4

+

i i

McGUIRE - UNIT 2 II.15-5 4 ,, _ . _ _ , , - - - - - . , . . _ - - ,.r. _.. ._ __,_,,._.., r.. . __,,._ , . , _ _ _.y -.. _ _ - ... __, - ,, y

. . - - - . - - . . . . . - . . - - - - - - - _ . - . ~ - . - - _ _ _ - - -.- .._- -.. - -- - . - . .

SYSTEM: CONTROL AREA CHIT. Tin WATER FLOW DIAGRAMS: MC-1618-1 FOR INFORMATION ONLY ,

System is Covered by Unit 1 IW I

i

  • i

!, l I

d i ,

i t t

l

O i

! I F

f 4

i 1

l 4

2 l 4 ,

i -

l 1 i r

I 1

i l

}

i i

l 1

j f

l'

(

i-McGUIRE - UNIT 2 II.16-1

<__.._..-._.___ _ _ u_2. _ _ _ _ . - ~ _ _ _ _ _ _ _ . _ . _ - _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ . - - -

A 0 System: Control Area Chilled Water E

S R 8

%  ? . n 3 a ~" ?8

$ 3 Valve Category u 3E t$

d 8 $

H TE

    • H E"

Valve Number Drawing Number A B C D Remarks 1YC-?A C MC-1618-1 11 - 2 X CT 40 sec. max. cycle time 1YC-13 C MC-1618-1 K-9 X MT 1YC-14 C MC-1618-1 K-10 X MT 1YC-16A C MC-1618-1 J-12 X CT 60 sec. max. cycle time 1YC-17B C MC-1618-1 Il-12 X CT 40 sec. max. cycle time 1YC-83B C MC-1618-1 F-2 X CT 40 sec. max. cycle time 1YC-94 C MC-1618-1 C-9 X MT 1YC-95 C MC-1618-1 C-10 X MT 1YC-99B C MC-1618-1 D-12 X CT 40 sec. max. cycle time 1YC-27B C MC-1618-1 E-14 X CT 40 sec. max. cycle time II.16-2 McGI5-UNIT 2 e e

r

] r e

t 3 a -

W e e e e e . 6 m m m m m 1 d i i i i i .

e t t t t t 1 1

l l e e e e e i l l l l l h c c c c c C y y y y y s c c c c c a k e r . . . . .

r a x x x x x A m a a a a a e m m m m m l R o . . . . .

r c c c c c t e e e e e n s s s s s o '

C 0 0 0 0 0 6 6 4 6 4 m

e #t 8$"

t s

y EY$H S

m" 8E*

~ $ Y" T T T T T 3ESa?& uEH C C C C C y D r

o g

- e C

\ t a

C Is X X X X X e

v l

a A V

4 2 2 2 2 1 1 1 1 1

  1. 328u - - - - -

F G F E E r

_ e b

. m u

N 1 1 1 1 1 g 8 8 8 8 8 n 1 1 1 1 1 i 6 6 6 6 6 w 1 1 1 1 1 a - - - - -

r C C C C C D M M M M M C C C C C 2 E$o T

I r N U

e -

b -

m .

u E N A A B A B R 0 9 9 8 0 I w e v

3 2

3 3

4

- C U

l C C C C C c a Y Y Y Y Y M .

V 1 1 1 1 1

i i

i i

SYSTEM: DIESEL GENERATOR ENGINE FUEL OIL

FLOk' DIAGRAMS: MC-2609-3.0

$ MC-2609-3.1 1

I l

! i i

.i i

I I

l 1

s 1

f i

e i

I A

i 1

i d

i a

i l

1 1

i 1

i 4

)

i i

j t

I I.

i l

II 17-1 l McGUIRE - UNIT 2

l i

O l

e 2

7 O

u 1 F I e I n

i g

n E s k

r r o a t m a e r R e

n e

G l

e s

e i

D m3 80M4 n0EH m $8E*

e t

s ~

  • Y*

y S

35!y E* T T M M uEH y D r

o t

g e

a C X X O C

B e

l v

a A V

3 3 1 1 m3!. ? 8U - -

E E r

e b

m 0 1 u .

N 3 3 g 9 9 n 0 0

_ i 6 6

_ w 2 2 a - -

r C C D M M C C

$Mo 2 T

I N

r U e

b -

m u E N 4 l

e v

2 9

D 0

1 D

- RO I

U G

c a F F M V 2 2

4 r

i f

I SYSTEM: DIESEL GENERATOR ROOM SUMP PUMP f FLOW DIAGRAMS: MC-2609-7.0 i

t i

i E

i t

i I

J I

4.-

i i

l

/

3 McGUIRE - UNIT 2 II.18-1

p m

P u

p m

2 8

- O u 1 S I I

m o

o R

r s o k t t t r u u a a h h r m s s e e n R d d e e e G i i f f l i i e r r s e e e V V i

D e3ME* &

wSMN m

e .

t s 5:$N y

S %d5 05Sa@$ T T T T T T M$ M M M M M H y D r

o t

C g

e a

C X X X X X X O

B e

l v

a A V

1 1 1 1 1 1 1 1 1 1 1 1 m3aa$0 - - - - - -

L K J F E D r

e b

/ m 0 0 0 0 0 0 u

N 7 7 ) 7 7 7 g

9 9 9 9 9 n 0 0 0 0 0 i

w M h'b 2

6 2

6 2

6 2

6 2

a -

r '

C C C C D " P > H M M M C C C C C C m$Y 2 T

I r N e U b -

m u E N

l e

v 3

N 5

N W

7 N

W 1

1 N

W 3

1 N

W 5

1 N

W

- RO I

U G

c a W M V 2 2 2 2 2 2

i 1

i SYSTEM: DIESEL GENERATOR STARTING AIR

! FLOW DIAGRAMS: MC-2609-4.0 1

1 i

1, i

i I

I l

4 5

i 4

I

(

)

i-1 a

i

)

l 1

1 1

i 4

a 1

4

)

1 l

4 i

.l 4

1 McGUIRE - UNIT 2 II,19 1 4

9

-- ,.--e,- ,.,,--,n.-, , . . ,- - - , , . ,.,r,,-ee w, , ,, --_--- ,,.n.-n~ ,-w --- .,, ., , , . . , . o,,--e,- . ,,-w,

System: Diesel Generator Starting Air m 0 e 3 5 3 8 8 B w%

e a a ta SS

@ y Valve Category y @. [$ g3

$ 0 05' NN 0%

Valve Number Drawing Number A B C D Remarks 2VG-62 C MC-2609-4.0 K-2 X CT X 2VG-61 C MC-2609-4.0 K-2 X CT X 2VG-64 C MC-2609-4.0 I-2 X CT X 2VG-63 C MC-2609-4.0 K-2 X CT X 2VG-65 C MC-2609-4.0 F-2 X CT X 2VG-66 C MC-2609-4.0 E-2 X CT X 2VG-68 C MC-2609-4.0 C-2 X CT X 2VG-67 C MC-2609-4.0 C-2 X CT X McGUIRE - UNIT 2 II.19-2 O O O

MC-2609-4.0 i

O VALVE: 2VG-61, 2VG-62, 2VG-63, 2VG-64, 2VG-65, 2VG-66, 2VG-67, 2VG-68 CATEGORY: B CLASS: C FUNCTION: Starting air solenoid control valves.

TEST REQUIREMENT: Verify valve operability every three months.

s BASIS FOR RELIEF: This valve is automatically opened when the diesel generator engine is started. The valve will then close after the engine is started. Failure of this valve to perform its required function should be indicated by the diesel's performance when it is periodically tested (once per 31 days). Direct observation of valve movement is impossible.

ALTERNATE TESTIFG: Valves will be considered to be functioning properly if the diesel's starting time is within tech. spec. limits.

P 4

b l

O McGUIRE - L' NIT 2 II.19-3

i I

i i

i

! SYSTEM: EQUIPMENT DECONTAMINATION 4

FLOW DIAGRAMS: MC-2568-1.0 i

l i

i

)

4 i

1 t

i I

t I

t

.c 1

1 j

4 i

i t

i t

i i

i l McGUIRE - UNIT 2 I II.20-1 i

4 b

J n.,---, - .--- . - --, , , - ,..,-w

n i

t o

a n

2 0

O i 2 m

a 1 1

t n

o c

e D s k

t r n a e m m e p R i e e u

q i v i v

E s s s s a a

P P m

e t

s y e3%63&

  • F F

S wdM$ R R 3$?$

Td$

058dE$ T T M$ L L y D r

o t

C g

e a

C X O B

e v

l a A X X V

8 )

m32$$0 E r

e b

m 0 0 u

N 1 1 g 8 8

_ n 6 6 i 5 5 w 2 2 a - -

r C C D M M mEU B B 2 T

I N

r U e

b -

m u E N

l e

v 3

1 E

3 2

E RO I

U G

c a W W M V 2 2

i I

l l

l, d

I SYSTEM: FEEDWATER I

! FLOW DIAGRAMS: MC-2591-1.1 i

I i

i i

i t

i:

1 1

1 t

t i

l 1

1 1

4 1

1 1

i i

i l

McGUIRE - UNIT 2 II.21-1

\ l 4

. . . . c c

e c

e

. 2O 1

c c c c e 2 e e e e s s s s s s s I 0 0 0 I 1

r 5 5 5 5 1 1 e 5 $

t 5 5 5 5 5 a e e e w s e e e e d k m m m m m m m e r i i i i i i t

i t

e a t t t t t F m n n n e n n n n R o o o o o o o

i i i i i i i t t t t t t t m a a a e a a a a l l t l l l l l s o o o o o o o y s s s s s s s I I I I S I I I m5t50N S S S S S S w4$$ C C C C C C 3:E$ X X X X X X

%M$

088a$$ T T T T T T CQ T

CQ

$$ CQ CQ CQ CQ CQ y D r

o t

C g

e a

C O

B X X X X X X X e

v l

a A V

3 3 6 9 1 3 3 6 mB8a$O 1 1

l I

1 1

1 1

1 1

1 1

1 1

r e

b m 1 1 1 1 1 1 1 u . . . . . . .

N 1 1 1 1 1 1 1

g 1 1 1 1 1 1 1 n 9 9 9 9 9 9 9 5

i 5 5 5 5 5 5 w 2 2 2 2 2 2 2 a - - - - - - -

r C C C C C C C D M M M M M M M 2

B B B B B B B

=$U T I

N U

r e -

b m E u R N 9 7 8 I 6 8 0 5 2 3 2 U l

e v

a 2

F C

2 F

C 3

F C

F 3

C 1

F C

1 F

C 1

F C

- GO M

c V 2 2 2 2 2 2 2

O b V U i '

%/

s' y , y System: Feedwater E E 6 '

. a 8 3 3 1 T 4

w 8

m

? u w

c

. o o +

g g Valve Category g j g U O $ $ $ Remarks Valve Number Drawing Number A B C D 2CF-136 B HC-2591-1.1 H-6 X CT Isolation time 5 10 sec.

2CF-127 B HC-2591-1.1 11 - 1 0 X CT X CS Isolation time 5 10 sec.

Q 4

2CF-135 B HC-2591-1.1 H-10 X CT Isolation time 5 10 sec.

Q 2CF-126 B HC-2591-1.1 H-13 X CT X CS Isolation time 5 10 sec.

9

.2CF-134 B HC-2591-1.1 H-13 X CT Isolation time < 10 sec. -

! q 2CF-104 B HC-2591-1.1 K-13 X CT X CS Isolation time 5 5 sec.

Q

) 2CF-105 B HC-2591-1.1 K-9 X CT X CS Isolation time 5 5 sec.

Q McGUIRE - UNIT 2 II.21-3 l

e e e i

t e

m i

t m

g i

t m

g i

t m

g i

t e

m 4 1

- O c c g 2 e e n n n n g s s i i i i n I t t t t i I r 5 5 a a a a t e r r r r a t < 5 e e e e r a p p p p e w s e e o o o o p d k m m o e r i i . .

x x

e a t t x x x

F m a a a a e n n m m m m a R o o . . .

m

i i .

m t t c c c c .

e a a e e e e c t l l s s s s e s o o s y s s 0 0 0 0 S I I .

1 1 1 1 5

$ N034 *5M$ S C

S C

S C

m$8s* %dE X X X T T T T T T T

.UE81l" ' . d CQ CQ CQ CQ CQ CQ CQ y D r

o C

g e

t a

C O

1 1 X X X X X X X e

l v

a A V

2 1 1 2 5 2 1 1 1 1 3 3aA oO K K

G G

G G

K r

e b

m 1 1 1 1 1 1 1 u . . . . . . .

N 1 1 1 1 1 1 1 g 1 1 1 1 1 1 1

. n 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 a - - - - - - -

r C C C C C C C

_ D M M M M M M M 2

mEU B B B B B B F T

I N

U r

e -

b m E u R N 3 5 7 O

I 6 7 1 0 0 5 5 5 5 7 U e 1 1 1 1 1 1 1 G v - - - - - - -

M c

l F F F F F F F a C C C C C C C V 2 2 2 2 2 2 2

V U m u y , y System: Feedwater

$ $ 6

. 8 8 3 8 1 ?

Q

, 8  ?

w a $ E O g g Valve Category g d g U O $ $ $

Valve Number Drawing Number A B C D Remarks 2CF-20 F MC-2591-1.1 K-6 X CT X CS 5 sec. max. operating time Q

2CF-23 F MC-2591-1.1 K-9 X CT X CS 5 sec. max. operating time Q

2CF-32 F MC-2591-1.1 K-13 X CT X CS 5 sec. max. operating time Q

McGUIRE - UNIT 2 II.21-5

l l

MC-2591-1.1 VALVE: 2CF-26, 2CF-28, 2CF-30, 2CF-35 CATEGORY: B CLASS: B FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve once per quarter.

BASIS FOR RELIEF: Closure would isolate the Steam Generator feedwater which could result in a severe transient in the Steam Generator which could result in a Unit trip.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

O O

McGUIRE - UNIT 2 II.21-6

l I

i MC-2591-1.1 VALVE: 2CF-20, 2CF-17, 2CF-23, 2CF-32 CATEGORY: B ,

i CLASS: F FUNCTION: Feedwater control.

TEST REQUIREMENT
Cycle and time valve once per quarter.

BASIS FOR RELIEF: Closure would isolate the steam generator feedwater which could result in a severe transiet in the steam generator which could result in a unit trip.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

l

\

l l

l r

O I

McGUIRE - UNIT 2 II.21-7

- -. ~ - . _ . - _ - _ . _ . , _ . - . . _ . . - - . . . , . - . . . . - - , . ..

MC-2591-1.1 O

VALVE: 2CF-129, 2CF-128, 2CF-127, 2CF-126 CATEGORY: B CLASS: B FUNCTION: Opens to provide startup feedwater supply to the steam generators.

TEST REQUIREMENT: Cycle and time valve once per three months.

BASIS FOR RELIEF: Cycling valve during power operation could induce unwanted transients in steam generators. This would result in an increase in flow to the main feedwater nozzles causing vibrations in the preheater section of the steam generators.

ALTERIATE TESTING: Valve will be cycled and timed during cold shutdowns.

l O

l l

l 1

- O er McGUIRE - UNIT 2 II.21-8

I J

l MC-2591-1.1

?

I VALVE: 2CF-104, 2CF-105, 2CF-106, 2CF-107 s

! CATEGORY: B f CLASS: B

. FUNCTION: Provides tempering flow to steam generators.

1 j TEST REQUIREMENT: Cycle and time valve quarterly.

i l BASIS FOR RELIEF: Cycling this valve during operation could result in loss j of S/G level control and result in a plant trip.

a ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

l 1

i i

i i

I I

i 1

a i

i t

3 d

1 i

l McGUIRE - UNIT 2 II.21 1

J l'

- - - - - , ~ + -

k 4

(

SYSTEM: FIRE PROTECTION i

i FLOW DIAGRAMS: MC-1599-2.2 i

l I

l J

i l

i McGUIRE - UNIT 2 II.22-1

i n

o 2

2 2

- O t

c 1 e 1 t

o r

P s

e k r r i a F m e

R

e m v e i t s s s y a S P sMy63%

a w?g$ F F R R

,$8?*%Z$ X my$85E* y$ T T T L MQL y D r

o t

C g

e a

C X O

B e

v l

a A X X V

=3EN$O 5 8

1 I r

e b

m 2 2 u

N 2 2

- g 9 9 n 9 9 i 5 5 w 1 1

_ a - -

r C C D M M mEU B B 2 T

I r N U

e b -

m u A E N 2 4 l

e v

a 3

8 F

R 3

8 F

R

- RO I

U C

c M

V I 1

- . . . . . - - ~_

l i

i I

MC-1599-2.2 t

a l VALVE: 1RF-834 i

! CATEGORY: A, C l

CLASS: B

! FUNCTION: Provide containment isolation.

1 TEST REQUIREMENT: Verify proper valve movement once per three months.

} BASIS FOR RELIEF: The system design does not provide any indication for j verifying valve closure upon flow reversal.

i j ALTERNATE TESTING: Valve will be verified shut by leak rate test performed

in accordance with Appendix J.

i i

4 I

t 1

i I

s I

J i

i l

f 4

i i

McGUIRE - UNIT 2 II.22-3 4

. . . ~ _ . , _ _ _ _ . _ . . _ _ . . _._ _. , _ _ . . _ _ _ . , , . . , . . . . . _ - . _ _ - _ _ _ _ . _ . _ _ _ _ _ _ . _ _ _ .

i l

i ,

SYSTEM: ICE CONDENSER REFRIGERATION j FLOW DIAGRAMS: MC-2558-4.0 i

i i

I l

1 l

l

! l

! 1 1

l l

l 4

}

i l

i i

}

t 1

i l McGUIRE - UNIT 2 4

II.23-1 i

i

System: Ice Condenser Hefrigeration E

. 8 e 3 1 3 8  ?

D w%

. a t* SS E o Valve Category M dE N$

U O $ $$ $N Valve Number Drawing Number A B C D Remarks 2NF-233B B MC-2558-4.0 K-12 X CT RF* Isolation time 5 15 sec.

Q LT 2NF-234A B MC-2558-4.0 K-13 X CT RF* Isolation time 5 15 sec.

Q LT 2NF-228A B MC-2558-4.0 K-13 X CT RF* Isolation time 5 15 sec.

Q LT 2NF-229 B MC-2558-4.0 F-13 X X MT RF*

q X LT 1

McGUIRE - UNIT 2 II.23-2 O O O

t MC-2558-4.0 I

l

! VALVE: 2NF-229 CATEGORY: A, C l

1 CLASS: B l

i FUNCTION: Provide containment isolation.

i i

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF
The system design does not provide any indication for ,

i verifying valve closure upon flow reversal.

1 ALTERNATE TESTING: Valve will be verified closed by leak test performed l

l in accordance with Appendix J.

l i

i 1

i i

i i

i i

1 i

e 1

i 1

i i

I a

t J

}

t 1

l

\

l

~

McGUIRE - UNIT 2 _II.23-3 .I

)

t

l 4 SYSTEM
INSTRUMENT AIR i

i

! FLOW DIAGRAMS: MC-2605-1.2 MC-2605-1.3 i

i f

! l

. 1

)

4 9

i l

i i

i l,

4 i

i i,

i t

i i

1 i

i i

i 1

i a

McGUIRE - UNIT 2 II.24-1

r c 2

4 O

i . . e c 2 A c c s e e e s I 5 I t s s n 1 5 e 5 5 1

m 1 1 $

u e e r s e e t k m m m m s r i i i i.

n a t t t t I m n n e n n o R o o o i

i i i m t t t t e a a a a l l l t l s o o o o y s s s s S I I I 1

$u w34 wMM$

  • F F

F F F F R R R R R R X X

.$8s"Yd$

myE 1s* M$ T T T T T T T T TT T T CQL CQL HQL MQL LCQ CQL y D r

o t

g e

a C

X X O

C B

e l

v a A X X X X X X V

1 2 3 4 5 4 1 m32Y$O C E B E D J r

e b

m 2 2 2 2 2 3 u

N 1 1 1 1 1 1 g 5 5 5 5 5 5 n 0 0 0 0 0 0 i 6 6 6 6 6 6 w 2 2 2 2 2 2 a - - - - - -

r C C C C C C D M M M M M M 2

m$U B B B B B B T

I N

U r

e -

b m E u B B A B R N

O 0 8 4 9 2 9 I 5 4 2 4 6 2 U e 1 1 1 1 3 1 G

v - - - - - - c l I I I I I I M

a V V V V V V V 2 2 2 2 2 2

~ - _ - . ... ... _ . . - . . . - _ . . _ _ . - . . . _ . . . . _ _ -.

. v v s m w

$ m U System: Instrument Air E $ 6 m 0 $ 3 3 a

  • F Q 2  ?

w a & E &

E o Valve Category $ M $

U O $ $ $

Valve Number Drawing Number A B C D Remarks 2VI-40 B MC-2605-1.3 J-13 X X MT X RF*

Q LT 2VI-160B B MC-2605-1.3 D-11 X CT RF* Isolation time <15 sec.

Q LT 2VI-161 B MC-2605-1.3 D-13 X X HT X RF*

Q LT

-McGUIRE - UNIT 2 II.24-3

i MC-2605-1.2 VALVE: 2VI-124, 2VI-149 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

O l

l e McGUIRE - UNIT 2 1

I i

l

. I i

i

.j t

j MC-2605-1.3  ;

i VALVE: 2VI-40, 2VI-161 CATEGORY: A, C 4

i CLASS: B i

1 l FUNCTION: Provide containment isolation.

l-4 TEST REQUIREMENT: Verify proper valve movement once per three months.

7 BASIS FOR RELIEF: The system design does not provide any indication for

} verifying valve closure upon flow reversal.

i j ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

l I

.i 1

1 1

i i

i i

4 i

k I

i 1 1 i i

! l 1

4 l

4 T

t McGUIRE - UNIT 2 II.24-5 1

s i

i i

SYSTEM: LIQUID WASTE RECYCLE FLOW DIAGRAMS: MC-2565-1.0 MC-2565-1.1 t

MC-2565-7.0 I

l l

l 4

i j

i l 1

J i

i n

3 3

4 s

,1 4

i 1

I i

l i

i 4

i l

4 i

i I

l 1

l McGUIRE - UNIT 2 II.25-1 l

m u y w y System: Liquid Waste Recycle E $ E m n 8 3 3 1 s 4

2  ?

w m A  % 0

$ o Valve Category M d M U O $ $ $

Valve Number Drawing Number A B C D Remarks 2WL-64A B tlc-2565-1.0 J-3 X CT RF* Isolation time $15 sec.

Q LT 2WL-65B B t1C-2565-1.0 K-5 X CT RF* Isolation time $15 sec.

Q LT 2WL-264 B  ?!C-2565-1.0 J-2 X LT RF* Passive 2WL-24 B ffC-2565-1.1 J-14 X X HT X RF*

Q LT 2WL-1B B flC-2565-1.1 L-11 X CT RF* Isolation time $10 sec.

Q LT 2WL-2A B ffC-2565-1.1 K-13 X CT RF* Isolation time $10 sec.

Q LT 11.25-2 e e

. - UNIT 2 McG6U

g s. ,

~

v -

v '

g '..

m w c p , g System: Liquid Waste Recycle

'~

E  % 6 -

m E $ 0 3 1 l 4 'A E F w -

m A  % &

g g Valve Category g j g U O -

0 $ $

Valve Number Drawing Number A B C D Remarks 2WL-39A B MC-2565-1.1 J-5 X CT RF* Isolation time $10 sec.

Q LT 2WL-41B B MC-2565-1.1 K-5 X CT RF* Isolation time $10 sec.

Q LT 2WL-321A B MC-2565-7.0 H-7 X CT RF* 15 sec. max. operating time Q

LT 2WL-322B B MC-2565-7.0 I-6 X CT RF* 15 sec. max. operating time Q

LT 2WL-385 B MC-2565-7.0 J-5 X X CT X RF*

Q LT I

McGUIRE - UNIT 2 II.25-3

1 I

l MC-2565-1.1 VALVE: 2WL-24 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

O t

l McGUIRE - UNIT 2 II.25-4

O MC-2565-7.0 VALVE: 2WL-385 CATEGORY: A, C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months. i I

BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

O l

O McGUIRE - UNIT 2 II.25-5

(. . . . . .

SYSTEM: MAIN STEAM FLOW DIAGRAMS: MC-2593-1.0 1

I I

P t

I i

l l

F k

I McGUIRE - UNIT 2 11.26-1

2 6

2

- O c c c c c c c c e e e e e e e e I m s s s s s s s s I a 5 5 e 5 5 5 5 1 1 5 5 t 5 5 5 5 5 5 S e e s e e e e e e n k m m m m m m m m i r i i i i i i i i a a t t t t t t t t M m n n e n n n n n n R o o o o o o o o

i i i i i i i i t t t t t m t t t a a e a a a a l l a a t l l l l l l s o o o o o o o o y s s s s s s s s I I I S I I I I I Suy802 w3%$ S S S S S S S S C C C C C C C C

,$$?* %d$ X X X X X X X X m y E81l* %$ T T T T T T T T C C C C C C C C y D r

o t

C g

e a

C O

B X X X X X X X X e

l v

a A V

3 3 3 3 3 3 3 3 m3a4gO 1 1 1 1 1 1 1 1 K J 1 1 G F E C B r

e b

m 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 n 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 a - - - - - - - -

r C C C C C C C C D H M  !

? M M l t

l t

t 2

.* U B B B B B B B B T

I N

U r

e -

b m E u B B B R N B B B A B A B A I l

e v

a A

1 l

i S

A 9

M S

A 3

M S

0 1

t S

A 5

M S

I 1

t S

A 7

t S

2 1

I

?

S

- GO U

i l

c V 2 2 2 2 2 2 2 2

! MC-2593-1.0

{:

VALVE: 2SM-1AB, 2SM-3AB, 2SM-5AB, 2SM-7AB, 2SM-9AB, 2SM-10AB, 2SM-11AB, 2SM-12AB 1

i CATEGORY: B CLASS: B a

~

FUNCTION: Main Steam Isolation Valves.

TEST REQUIREMENT: Cycle and Time Valves Quarterly.

j BASIS FOR RELIEF: 2SM-1, 3, 5, and 7, MSIV's, cannot be full stroke exercised during power operation since shutting an j MSIV could result in a plant shutdown. Tech. Specs.

do not permit isolation of a steam generator. 2SM-9 10, 11, and 12, MSIV Bypass valves, will be full stroke

! exercised quarterly. However, these valves cannot be timed at this frequency since this operation will be done utilizing a manual loader.

ALTERNATE TESTING: These valves will be partially stroked at least once per 92 days in accordance with PT/2 /A/4250/01A (Main Steam Isolation Valve Movement Test). These valves will be full (O~

(

stroked and timed at cold shutdown. 2SM-9, 2SM-10, 2SM-11, and 2SM-12 will be full stroked quarterly and timed.

1 O

{'% McGUIRE - UNIT 2 II.26-3 '

_ _ - _ ~ - _ _ .- -

d j

1

) SYSTEM: MAIN STEAM SUPPLY TO AUXILIARY EQUIPMENT / TURBINE EXHAUST 1,

! FLOW DIAGRAMS: MC-2593-1.2 i

i i

J l

1

)

I I

l

!O j

r I

i l

j i

I i

4 J

]

l 1 l 2

McGUIRE - UNIT 2 II.27-1 1

l l

y r

at i s l u i a e e 2

7 O

xh m m 2 ux i i I

AE t t I

ye e e l n l l pi c c pb y y ur s c c S u k T r . .

m/ a x x at m a a en e m m t e R S mp . .

c c ni e e i u s s a q ME 0 0 5 5 m

e m3UE3$

t s

wSM$

y S .

O" @N tdE my$e1E* M$ T T C C y D r

t o

g e

a C O C

B X X e

v l

a A V

5 5 mB8$8O F G

r e

b m 2 2 u

N 1 1 g 3 3 n 9 9 i 5 5 w 2 2 a - -

r C C D M M mag B B 2 T

I r N e U b -

m u B B E N A A l

e v

8 4

A 9

4 A

RO I

U G

c a S S M V 2 2

SYSTEM: MAIN STEAM VENT TO ATMOSPHERE FLOW DIAGRAMS: MC-2593-1./

MC-2593-1.3 }

O l

O McGUIRE - UNIT 2 II.28-1

h System: Main Steam Vent to Atmosphere 5

m  ? e 3 1 3 8  ? D w%

a 5 #

E$ $E

$ o Valve Category M l@ M3 Y 0 $ $$ $&

Valve Nuniber Drawing Number A B C D Remarks 2SV-13A,B B MC-2593-1.0 L-4 X CT 20 sec. max. cycle time 2SV-14 B MC-2593-1.0 K-5 X SP 2SV-15 B MC-2593-1.0 K-7 X SP 2SV-16 B MC-2593-1.0 K-9 X SP 2SV-17 B MC-2593-1.0 K-10 X SP 2SV-18 B MC-2593-1.0 K-12 X SP 2SV-19A,B B MC-2593-1.0 G-5 X CT 20 sec. cycle time 2SV-20 B MC-2593-1.0 E-5 X SP 2SV-21 B MC-2593-1.0 E-7 X SP 2SV-22 B MC-2593-1.0 E-9 X SP McGUIRE - UNIT 2 11.28-2 9 9 9

_ \ e Vh e s

r p

e e 3

8

_. o m i m

i m 2 t t t I A 1 e e o l l t c c

_ y y t s c c n k e r . .

V a x x m a a m e m m a R e . .

t c c S e e -

s s n

i 0 0 a 2 2 M

e3%53N m w4g$

e t

s y " :5$

S tj$

hE02l* y$ P P T P P P P P T P S S C S S S S S C S y D r

/. o

( ( t g

e a

C X X X X X X X X C

B X X e

v l

a A V

aB2agO 0 2 1 2 1 1 5 6 7 9 1 1 5 6 _

E E L K K K K K G E _

r e

b m 0 0 3 3 3 3 3 3 3 3 u

N 1 1 1 1 1 1 1 1 1 1 g 3 3 3 3 3 3 3 3 3 3 n 9 9 9 9 9 9 9 9 9 9 i 5 5 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 2 2 a - - - - - - - - - -

r C C C C C C C C C C D M M M M M M H H M M B B B B B B B B B B

=$U 2 T

I r N e U b -

m u B, B E N ,

R 3 4 A A 0U e v

2 V

2 V

1 V

2 V

3 V

4 V

5 V

6 V

7 8

I U

G l V V c a S S S S S S S S S S M V 2 2 2 2 2 2 2 2 2 2

! l lllllll(,lt! !1j! l l

e h

r e

p s

4 8

O o 2 m 1 t

A 1 o

t t

s n k e r V a m

m e a R e

t S

n i

l a

t

e3%63%

m e wd$0 t

s y 3$EN S YM$

$0a?* $0 P P P P S S S S y D r

o t

g e

a C X X X X O C

B e

v l

a A V

1 2 7 9 1 1 m38Y o0 - - - -

E E E E r

e b

m 3 3 3 3 u

N 1 1 1 1 g 3 3 3 3 n 9 9 9 9 i 5 5 5 5 w 2 2 2 2 a - - - -

r C C C C D  !

?

?

t

?

B B B B mE$ 2 T

I r N e U b

m -

u N E l

e v

9 V

0 1

V 1

1 V

2 1

V RO I

U G

a S S S S c V 2 2 2 2 M

i s

i i SYSTEM: MAKEUP DEMINERALIZED WATER FLOW DIAGRAMS: MC-1601-2.4 l 1

2, I

i i

1, 1

I l

i l

i 4

i i

1 i

2 4

1 i

i i

l l

l l

t j J

' J i

i l McGUIRE - UNIT 2 II.29-1 i

r e

t W

d a

d s

n o

2 2

9

- 9 e c z e I i s . I l

a 5 r 1 e

n s _ e i k m m r i e a t D m e n p R o u i e t k a a l M o s

I m

e t

3%S3& *

  • s F F S

y wSNO R R 3* EN X td$

h$E1s* M$ TT TT CL HL y D r

o t

C g

e a

C B

X 9

e v

l a A X X V _

8 4 m33a$0 - -

C C r

e b

m 4 4 u

N 2 2 g 1 1 n 0 0 i 6 6 w 1 1 a - -

r C C D M M B B m$0 2 T

I r _ N e _ U b -

m u B E N 5 6 R U9 1 1 I

e 1 1 v - - G l M M c a Y Y M V 2 2

i MC-1601-2.4 I

4

. VALVE: 2YM-116 i

j CATEGORY: A, C CLASS: B

(

.i  !

j FUNCTION: Provides containment isolation.

l TEST REQUIREMENT: Verify proper valve movement once per three months.

t BASIS FOR RELIEF: The system design does not provide any indication for  !

l '

! verifying valve closure upon flow reversal.

j ALTERNATE TESTING: Valve will be verified closed by leak test performed l in accordance with Appendix J.

i 1

4 i

i 1

i i

j i

I 4

1 I

i i

1 l

i I

i i

i i

a l

I

1 i' i McGUIRE - UNIT 2 II.29-3 i

, , -,- e--,-.,- - , - - , --- - , . - , -- - , - --- -----------..,w-.,

SYSTEM: NUCIIAR SAMPLING FLOW DIAGRAMS: MC-2512-1.0 MC-2572-1.1 MC-2572-3.0 O l 1

McGUIRE - UNIT 2 II.30-1

8 m w y , y System: Nuclear Sampling 8 $ E m 8 8 3 3 4  ?

8 s w m A $ 5

@ g Valve Category y j g U O $ $ $

Valve Number Drawing Number A B C D Remarks 2NM-3A B MC-2572-1.0 K-3 X CT RF* Isolation time $15 sec.

Q LT 2Nft-6A B MC-2572-1.0 J-3 X CT RF* Isolation time $15 sec.

Q LT 2NM-7B B MC-2572-1.0 K-6 X CT RF* Isolation time $15 sec.

Q LT 2NM-67 B MC-2572-1.0 K-4 X X LT RF*

2NM-26B B MC-2572-1.0 K-8 X CT RF* Isolation time $15 sec.

Q LT 2NM-25A B MC-2572-1.0 K-12 X CT RF* Isolation time $15 sec.

Q LT II.30-2 e e IRE - UNIT 2 Mec

v A

V m u U m N System: Nuclear Sampling E $ 6 m B 8 8 8 1 *

? 4 a

  • l w m a t 4 E $ Valve Category $ d $

U O $ $ $

Valve Number Drawing Number A B C D Remazks 2NM-22A B HC-2572-1.0 J-12 X CT RF* Isolation time 515 sec.

Q LT 2NM-68 B HC-2572-1.0 K-11 X X LT RF*

2NM-728 B MC-2572-1.1 I-6 X CT RF* Isolation time $15 sec.

Q LT 2NM-75B B MC-2572-1.1 I-8 X CT RF* Isolation time 515 sec.

Q LT 2NM-78B B MC-2572-1.1 I-9 X CT RF* Isolation time $15 sec.

Q LT 2NM-818 B MC-2572-1.1 1-11 X CT RF* Isolation time $15 sec.

Q LT McGU1RE - UNIT 2 11.30-3

$ t System: Nuclear Sampling 5 0 E S : e 3  ?

a a

  • 5 a -  ?

g j Valve Category u j j 0

o 8 E Y $

Valve Number Drawing Number U A B C D b M H Remarks 2NM-69 B MC-2572-1.1 G-9 X LT RF* Passive 2NM-82A B MC-2572-1.1 E-9 X CT RF* Isolation time <15 sec.

Q LT 2NM-187A B  ?!C-2572-3.0 K-1 X CT Isolation time $15 sec.

Q 2N!!-190A i. MC-2572-3.0 K-2 X CT Isolation time $15 sec.

Q 2N?l-1918 B MC-2572-3.0 I-2 X CT Isolat. ion time $15 sec.

Q 2NM-197B B flC-2572-3.0 K-5 X CT Isolation t.ime $15 sec.

Q 2NM-200B B MC-2572-3.0 K-6 X CT Isolation time $15 sec.

Q McGUIRE - UNIT 2 II.30-4 O O O

( 0 V

(../ V E

m u U m U System: Nuclear Sampling E $ 6 m 8 8 3 3 1 E

" 4 1 2 l w m Y I d 4

E o Valve Category M M $

U O $ $ $

Valve Number Drawing Number A B C D Remarks 2NM-201A B MC-2572-3.0 I-6 X CT Isolation time 515 sec.

Q 2NM-207A B MC-2572-3.0 K-8 X CT Isolation time $15 sec.

t Q 2NM-210A B HC-2572-3,0 K-9 X CT Isolation time $15 sec.

Q 2NM-211B B MC-2572-3.0 I-9 X CT Isolation time $15 sec.

Q 2NH-217B B HC-2572-3.0 K-11 X CT Isolation time $15 sec.

Q

, 2NM-220B B MC-2572-3.0 K-12 X CT Isolation time $15 sec.

Q t

2NM-221A B MC-2572-3.0 1-12 X CT Isolation time $15 sec.

Q i

McGUIRE - UNIT 2 11.30-5

SYSTEM: NUCLEAR SERVICE WATER FLOW DIAGRAMS: MC-1574-1.0 MC-1574-1.1 MC-2574-1.1 l

MC-2574-2.0 MC-2574-2.1 MC-2574-3.0 MC-2574-3.1 MC-2574-4.0 1 The valves found on drawing MC-1574-1.0 are shared by both units. They are covered under the Unit 1 Inservice Testing Program, and they are presented here for information only.

l O

O McGUIRE - UNIT 2 II.31-1

m System: Nuclear Service Water E $

m E E o 3 1  ? 3 E w%

m $ T ME E E Valve Category M d M*

C e e a 3%

Valve Number Drawing Number A B C D Remarks IRN-7A C MC-1574-1.0 J-9 X CT 60 sec. max. cycle time IRN-2B C MC-1574-1.0 K-10 X CT 60 sec. max. cycle time IRN-3A C MC-1574-1.0 K-10 X CT 60 sec. max. cycle time IRN-13A C MC-1574-1.0 J-11 X CT 60 sec. max. cycle time IRN-12A,C C MC-1574-1.0 I-11 X CT 60 sec. max. cycle time IRN-14A C MC-1574-1.0 I-13 X CT 60 sec. max. cycle time IRN-15B C MC-1574-1.0 F-13 X CT 60 sec. max. cycle time IRN-4A C MC-1574-1.0 F-12 X CT 60 sec. max. cycle time IRN-5B C MC-1574-1.0 E-12 X CT 60 sec. max. cycle time IRN-10A,C C HC-1574-1.0 G-11 X CT 60 sec. max. cycle time McGUIRE - UNIT 2 I1.31-2 O O O

- - s_ .-

m u y , y System: Nuclear Service Water

$ $ 6 m 8 8 8 3 1 F G

2 E w

" 3 m 4  %

g g Valve Category g d g U O $ $ $

Valve Number Drawing Number A B C D Remarks IRN-11B C MC-1574-1.0 F-11 X CT 60 sec. max. cycle time 1RN-1 C MC-1574-1.0 I-10 X CT 60 sec. max. cycle time 1RN-301A,C C MC-1574-1.0 G-10 X CT 60 sec. max. cycle time IRN-302B C MC-1574-1.0 F-10 X CT 60 sec. max. cycle time IRN-9B C MC-IS74-1.0 D-9 X CT 60 sec. max. cycle time IRN-149A C MC-1574-1.0 J-7 X CT 60 sec. max. cycle time IRN-152B C MC-1574-1.0 E-7 X CT 60 sec. max. cycle time IRN-150A C MC-1574-1.0 I-6 X CT 60 sec. max. cycle time IRN-151Il C MC-1574-1.0 F-6 X CT 60 sec. max. cycle time 1RN-299A C HC-1574-1.0 K-2 X CT 60 sec. max. cycle time McGUIRE - UNIT 2 II.31-3

h , System: Nuclear Service Water m 0 $ o 3 4 *

? 3 2 l wt a 5  % 08

$ $ Valve Category g j g3 U O $ $ $Q Valve Number Drawing Number A B C D Remarks IRN-279B C MC-1574-1.0 K-2 X CT 60 sec. max, cycle time IRN-64A C HC-1574-1.0 I-2 , X CT X CS 60 sec. max. cycle time IRN-63B C HC-1574-1.0 I-2 X CT X CS 60 sec. max. cycle time IRN-296A C MC-1574-1.0 1-1 X CT 60 sec. max. cycle time IRN-147A,C C MC-1574-1.0 11 - 2 X CT 60 sec. max. cycle time IRN-148A C NC-1574-1.0 II-3 X CT 60 sec. max. cycle time 1RN-297B C  !!C- 1574- 1. 0 G-2 X CT 60 sec. max. cycle time IRN-283A,C C MC-1574-1.0 F-2 X CT 60 sec. max. cycle time IRN-284B C MC-1574-1.0 F-2 X CT 60 sec. max. cycle time McCUIRE - UNIT 2 II.31-4 O O O

c v

v e System: Nuclear Service Water

$ N m 0 $ e 3 1 F 3 2 "

l w%

e a 1 SE

$ $ Valve Category  % d  %$

a 0 $ N Aa Valve Number Drawing Number A B C D Remarks 2RN-21A C MC-2574-1.1 J-2 X CT X CS 60 sec. max. cycle time 2RN-16A C MC-2574-1.1 J-3 X CT 60 sec. max. cycle t.ime 2RN-22A C MC-2574-1.1 H-5 X CT X CS 60 sec. max. cycle time 2RN-28 C MC-2574-1.1 J-9 X MT 2RN-68A C MC-2574-1.1 K-12 X CT 60 sec. max. cycle time 2RN-40A C MC-2574-1.1 1-12 X CT 60 sec. max. cycle time IRN-41B C NC-2574-1.1 F-12 X CT 60 sec. max. cycle time IRN-43A C MC-2574-1.1 F-12 X CT 60 sec. max. cycle time 2RN-18B C MC-2574-1.1 E-2 X CT 60 sec. max. cycle time 11.31-5 McGUIRE - UNIT 2

m System: Nuclear Service Water

$ N m 0 $ e 3 1 F 3 e *

? w%

e a t SE

$ $ Valve Category $  % M3 U 0 $ 5 AQ Valve Number Drawing Number A B C D Remarks _

2RN-26B C MC-2574-1.1 G-5 X CT X CS 60 sec. max. cycle time 2RN-25B C MC-2574-1.1 C-4 X CT X CS 60 sec. max. cycle time 2RN-30 C MC-2574-1.1 E-9 X MT 2RN-161B C MC-2574-1.1 B-13 X CT 60 sec. max. cycle time 2RN-41B C MC-2574-1.1 F-12 X CT 60 sec. max. cycle time 2RN-43A C MC-2574-1.1 F-12 X CT 60 sec. max. cycle time 2RN-296A C MC-2574-1.1 1-1 X 60 sec. max. cycle time 2RN-297B C MC-2574-1.1 G-2 X 60 sec. max. cycle time 11.31-6 McGUTRE - UNIT 2 O O O

- . ____ .. . . __ . _ __ .m . _ . . __ . - . _ _ .__ __ __ __

Q Q/ J m

y , System: Nuclear Service Water E $

e E E e 5 a "

s 3 E l w#

m a t SE g Valve Category g g g3 0 0 $ $ O&

Valve Number Drawing Number A B C D Remarks

-2RN-166A C MC-2574-2.0 J-2 X CT 60 see. max. cycle time 2RN-70A C MC-2574-2.0 E-6 X CT 60 sec. max. cycle time 2RN-69A C HC-2574-2.0 I-3 X CT 10 sec. max. cycle time 2RN-73A C MC-2574-2.0 1-6 X CT 60 sec. max. cycle time 2RN-112A C MC-2574-2.0 I-6 X CT 60 sec. max. cycle time 2FN-117A C MC-2574-2.0 I-10 X CT 60 sec. max. cycle time 2RN-86A C MC-2574-2.0 D-12 X CT 60 sec. max. cycle time 2RN-89 C HC-2574-2.0 '

J-12 X CT 60 sec. max. cycle time 2RN-140A 'C . MC-2574-2.0 E-14 X CT _, 15 sec. max. cycle time s s McGUIRE - UNIT 2 - II.31-7

.i- ,

4 9

&, e

. .e _ *_ __ _ . - _ _ _ . _ _ _ _ _ _ _ _ __

m System: Nuclear Service Water m 8 8 e 3 1  ?

3 3 E w#

. 1 *

  • SE E $ Valve Category M d M3 U O N N $&

Valve Number Drawing Number A B C D Remarks 2RN-103A C MC-2574-2.1 C-6 X CT 15 sec. max. cycle time 2RN-81A C MC-2574-2.1 I-3 X CT 60 sec. max. cycle time 2RN-134A C MC-2574-2.1 C-7 X CT 60 sec. max. cycle time 2RN-137A C MC-2574-2.1 11 - 7 X CT 60 acc. max. cycle time 2RN-126A C MC-2574-2.1 D-9 X CT 15 sec. max. cycle time 2RN-130A C HC-2574-2.1 C-10 X CT 15 sec. max. cycle time 2RN-114A C HC-2574-2.1 B-11 X CT 15 sec. max. cycle time 2RN-85A C MC-2574-2.1 I-12 X CT 60 sec. max. cycle time McGUIRE - UNIT 2 II.31-8 O O O

.;: w

'^

w g

-mv' w./ 8/

h , System: Nuclear Service Water E $

m 8 $ e 3 1 s 3

2 l w%

= a t 45 y g Valve Category g j g3 U O $ $ $N Valve Number Drawing Number A B C D Remarks 2RN-170B C MC-2574-3.0 J-2 X CT 60 sec. max. cycle time 2RN-171B C MC-2574-3.0 F-7 X CT 40 sec. max. cycle time 2RN-174B C HC-2574-3.0 I-7 X CT 60 sec. max. cycle time 2RN-162B C MC-2574-3.0 K-7 X CT 10 sec. max. cycle time 2RN-213 C MC-2574-3.0 J-5 X CT 60 sec. max. cycle time 2RN-218 C MC-2574-3.0 J-7 X CT 60 sec. max. cycle time 2RN-187B C MC-2574-3.0 F-12 X CT 60 sec. max. cycle time 2RN-190B C MC-1574-3.0 J-12 X CT 00 sec. max. cycle time 2RN-240B C, MC-2574-3.0 D-13 X CT 15 sec. max. cycle time McGUIRE - UNIT 2 II.31-9

r e 0 t

a 1 W e e e e e e e e 1 e m m m m m m m m 3 i

c i i i i i i t

i t t I i t t t t t v e e e e e I

r e e e e l l l l l l c

l c

l c

S c c c c c y y y y y y y y r s c c c c c c c c a k e r . . . . . . .

x l a x x x x x x x a

c m a a a a a a a u e m m m m m m m m N R . . . . . . .

c c c c c c c c e

e e e e e e e m s s s s s s s s e 0 t 5 0 0 0 5 5 5 s 1 6 6 6 1 1 1 6 y

S o3tE$N wS%$ _

m mE?* t%$

EE1?* %$ T C

T C

T C

T C

T C

T C

T C

T C

y D r

o g

e C t

a C

B X X X X X X X X e

v l

a A V

0 0 1 2 m38e$O 5 3

7 7

1 1

1 1

C I E I E C B I r

e b

1 1 1 1 1 m 1 1 1 u . . . . . . . .

N 3 3 3 3 3 3 3 3 g 4 4 4 4 4 4 4 4 n 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 a - - - - - - - -

r C C C C C C C C D M M M M M M M M mEU C C C C C C C C 2 T

I r N U

e b -

m u B B B B B B B B E N 4 2 5 8 7 1 5 6 0 8 3 3 2 3 1 8 e 2 1 2 2 2 2 2 1 v - - - - - - - -

l N N N N N N N N c a R R R R R R R R M V 2 2 2 2 2 2 2 2 _

[ \ /O b'\

v v -

v_

h . System: Nuclear Service Water m 8 8 .

B 1  ? 3 8 F w#

l m U I Md E $ Valve CateRory  %  % $'

U O $ $ $$

Valve Number Drawing Number A B C D Remarks 2RN-252B C HC-2574-4.0 E-2 X CT X CS Isolation time $30 sec.

LT 1

l 2RN-253A C HC-2574-4.0 C-2 X CT X CS Isolation time $30 sec. l LT l

1 HC-2574-4.0 X Isolation time $30 sec.

2RN-276A C J-2 X CT CS LT 2RN-277B C HC-2574-4.0 I-2 X CT X CS Isolation time 130 sec.

LT 2RN-42A C HC-2574-4.0 B-9 X CT X CS 60 sec. max. cycle time 2RN-63B C HC-2574-4.0 L-10 X CT X CS 60 sec. max. cycle time 2RN-64A C HC-2574-4.0 L-11 X CT X CS 60 sec. max. cycle time l McGUIRE - UNIT 2 11.31-11

MC-1574-1.0 VALVE: IRN-63B, IRN-64A l CATEGORY: B CLASS: C FUNCTION: Isolates Nuclear Service Water System-Non-essential Header.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit cooling flow to several heat exchangers. This action could result in damage to the equipment served by these heat exchangers. This equipment includes the PD charging pump and the computer room A/C.

l ALTERNATE TESTING: This valve will be tested during cold shutdowns.

1 l

b i

l

(

II.31-12 McGUIRE - UNIT 2

l e

MC-2574-1.1 VALVE: 2RN-21A, 2RN-22A, 2RN-25B, 2RN-26B CATEGORY: B j CLASS: C FUNCTION: Regulate to backflush Nuclear Service Water Strainer 2A &

i 2B when D/P setpoint is reached, i

TEST REQUIREMENT: Verify valve operability every three months.

1 BASIS FOR RELIEF: These valves automatically regulate to provide flow

{ for backwashing the strainer. These valves are not provided with sufficient manual controls to permit testing. Normal operation should verify valve i operability.

i j ALTERNATE TESTING: Valves will be timed at cold shutdowns.

1 i

1 l

1 1

i i

i i

l .

1 i

i

\

J McGUIRE - UNIT 2 II.31-13 4

,r,~ * - - , - r- - , , , a

l 1

l MC-2574-4.0 VALVE: 2RN-252B, 2RN-253A CATEGORY: A CLASS: B FUNCTION: Provides containment isolation.

t TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: These valves must remain open to maintain cooling water to the Reactor Coolant Pump Motor Air Cooler. If one of these valves were to fail in the closed position during testing, the flow would be restricted. This action could result in damage to the Reactor Coolant Pump Motors.

ALTERNATE TESTING: These valves will be tested during cold shutdowns.

1 O

l l

r O

McGUIRE - UNIT 2 II.31-14

1 I

i -

MC-2574-4.0 1

4 VALVE: 2RN-276A, 2RN-277B l

CATEGORY: A

)

i CLASS: B

FUNCTION
Provides containment isolation.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: These valves must remain open to maintain the cooling water flow path for the Reactor Coolant Pump Motor Air l

~

Coolers. If one of these valves were to fail in the closed position during testing, the flow would be d

restricted. This action could result in damage to the Reactor Coolant Motors.

ALTERNATE TESTING: These valves will be tested during cold shutdowns.

1 l

J i

f 4

1 1

l l

)

McGUIRE - UNIT 2 II.31-15 i

MC-2574-4.0 (s

VALVE: 2RN-42A CATEGORY: B CLASS: C FUNCTION: Isolates Nuclear Service Water System-Non-essential Header.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit cooling flow charging pump. This action could result in damage to the equipment served by these heat exchangers. This equipment includes the PD charging pump and the computer room A/C.

ALTERNATE TESTING: This valve will be tested during cold shutdowns.

O e.

McGUIRE - UNIT 1 II.31-16

MC-2574-4.0 O

VALVE: 2RN-63B, 2RN-64A CATEGORY: B CLASS: C l FUNCTION: Isolates Nuclear Service Water System Non-essential Header.

TEST REQUIREMENT: Cycle and time valve every three months.

BASIS FOR RELIEF: Failure of this valve in the closed position during testing would inhibit cooling flow to several heat exchangers. This action could result in damage to the equipment served by these heat exchangers. This equipment includes the PD charging pump and the computer room A/C.

ALTERNATE TESTING: This valve will be tested during cold shutdown.

O O

McGUIRE - UNIT 2 II.31-17

i

f

.I l

SYSTEM
REACTOR COOLANT SYSTEM i

FLOW DIAGRAMS: MC-2553-2.0 MC-2553-4.0 l

t

lt

}

l t

i i

i l

1 i

i i

i

\

t 4

)

i i

1 J

f 1

4 J

t l

I I i

i l McGUIRE - UNIT 2 II.32-1 4

i

4 e w

$ . # System: Heat.'or Coolant E $ 8 I m E $ 0 3 1

  • l 2 E E w l

" 5 j m 5 E  !

E $ Valve Category M d M U O $ $ $

Valve Number Drawing Number A B C D Remarks l l

2NC-36B A MC-2553-2.0 G-2 X CT X 2.0 second cycle time l MC-2553-2.0 G-3 X CT X 2.0 second cycle time 2NC-34A A i

MC-2553-2.0 G-5 X CT X 2.0 second cycle time 2NC-32B A 2NC-1 A MC-2553-2.0 K-3 X SP Set at 2485 PSIG 2NC-2 A MC-2553-2.0 K-4 X SP Set at 2485 PSIG 2NC-3 A MC-2553-2.0 K-5 X SP Set. at 2485 PSIG 2NC-54A B MC-2553-2.0 11 - 9 X CT Isolation time $10 sec.

LT 2NC-53B B MC-2553-2.0 11 - 1 0 X CT Isolation time $10 sec.

LT 2NC-57 B MC-2553-2.0 F-13 X X LT Passive 1

l McGUTRE - UNIT 2 II.32-2 O O O l J

U V $

M v4 y e y System: Reactor Coolant 8 $ 6

. 8 8 3 3 1 T Q 8

? w

. 4  % 3

$ $ Valve Category M 'j  %

U O $ $ $

Valve Number Drawing Number A B C D Remarks 2NC-56B B MC-2553-2.0 D-14 X CT Isolation time $10 sec.

LT 2NC-272A,C A MC-2553-2.0 J-9 X CT X CS thx. Cycle time 5,60 sec.

2NC-273A,C A MC-2553-2.0 J-9 X CT X CS Max. Cycle time 5,60 sec.

2NC-29C A MC-2553-2.0 D-11 X CT X 2NC-27C ~

A MC-2553-2.0 C-11 X CT X_ _

~ 2NC-195B B MC-2553-4.0 1-8 X LT Passive 2NC-196A B MC-2553-4.0 H-8 X LT Passive 2NC-141 B MC-2553-4.0 C-9 X PC RF*

LT 2NC-142 B MC-2553-4.0 D-9 X PC RF*

LT 2NC-261 B MC-2553-4.0 C-8 X X LT X RF*

2NC-259 B MC-2553-4.0 H-8 X X LT X RF*

McGUIRE - UNIT 2

MC-2553-4.0 VALVE: 2NC-259, 2NC-261 CATEGORY: A, C CLASS: B FUNCTION: Thermal overpressurization relief.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASISFOR RELIEF: Valves have no indication of closure.

ALTERNATE TESTING: Valves will be verified shut by leak test performed in accordance with Appendix J.

O 1

O McGUIRE - UNIT 2 II.32-4

i s

i MC-2553-2.0 a

l[

i( VALVE: 2 NC-36B . 2NC-34A, 2NC-32B j

CATEGORY: B

]

CLASS: A q FUNCTION: Reactor Coolant System PORV.

} TEST REQUIREMENT: Full stroke exercise quarterly.

f BASIS FOR RELIEF: PORV's do not serve a safety related function when unit is at operating temperature and pressure. PORV's a protect RCS from low temp. overpressurization.

i

)

ALTERNATE TESTING: Valves will be tested in accordance with technical 3 specifications which require cycling of PORV every j 18 months.

i i

i i

i l

1 j

l i

t i

f I

! McGUIRE - UNIT 2 11.32-5 4

4

'=

k

-_ --,.-,--_r.. . . , . . - _ _ - . . - _ . , . . . . . . . , - - ., .___... . . . , _ . - . . . - _ < , - - _ .

,,-.-.,.,,m..--, - - , - . . , . - - -

MC-2553-2.0 VALVE: 2NC-272A,C, 2NC-273A,C O

CATEGORY: B CLASS: A FUNCTION: Reactor Vessel Head Vent TEST REQUIREMENT: Cycle and time every three months.

BASIS FOR RELIEF: Opening of either of these valves during power operation could cause a loss of coolant.

ALTERNATE TESTING: Valves will be cycled at cold shutdown.

O

i

! MC-2553-2.0 II j VALVE: 2NC-27, 2NC-29 CATEGORY: B CLASS: A FUNCTION: Pressurizer Spray Control TEST REQUIREMENT: Cycle and time valve quarterly.

BASIS FOR RELIEF: Valve has no open or closed indication.

ALTERNATE TESTING: Valve will be verified operable quarterly by partial

stroking. A change in RCS pressure will indicate proper i valve operation.

i I

1 i

l l

I 4

i

+

1 .

f I

t McGUIRE - UNIT 2 11.32-7 i

( _ . . - , _ _ _ , . _ . . . _ . ._ _ _ . _ ._

l SYSTEM: REFUELING WATER i FLOW DIAGRAMS: MC-2571-1.0 l

I I

l l

McGUIRE - UNIT 2 II.33-1 I

Ill l\l l 1l 4

lllI t

r e

i t

e m

g i

t e

m g

i t

e m

g i

t e

m g

2 3

3

- e a n n n n W i t

i t

i t

i t

1 1

g a a a a n r r r r i e e e e l p p p p e s o o o o u k f r . . . .

e a x x x x R m a a a a e m m m m R

e e e e . .

c c

m v v v v c c e e e e i i i i e t s s s s s s s s s s s s s y a a a a 0 0 0 0 S P P P P 1 1 1 1 wNS3% w&M$

  • F F

F R R R mM8?*EM$

eU8E1i" $$ T L

T L

T L

T L

T CQ T

CQ T

CQ T

CQ y D r

t C

o g

e a

C B

X X X X X e

e l

v a A X X X X V

0 1 1 1 m3a& oO 7 7

4 5

1 1

1 1

C F G G F F E E r

e b

m 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 g 1 1 1 1 1 1 1 1 n 7 7 7 7 7 7 7 7 i 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 a - - - - - - - -

r C C C C C C C C D M M M M M M M M 2

mEU B B B B B B B B T

I N

U r

e -

b m E u R N B A B 3 A 8c 1 9 3 2 e 5 4 1 1 4 3 I 3 v - - - - - - - -

l a

W F

W F

WF W

F W

F W

F W

F WF M

V 2 2 2 2 2 2 2 2 lf1l'( llllllll l 1l l

,'% 3 r -

e e 3 t m 3 a i W t 1 1

g e n l i c l y e s c u k f r .

e a x R m a e m R

. e m c v e e i t s s s s y 0 a S 3 P S F

$wu 0Q e&gO C R

,$$?* E[N X myE01?#y$ T T T T CQ MQ L M y D r

/ o g

'l% t e C X X X a

C B X e

l v

a A X V

2 1 e385g0 1 1 7 5 C B D I r

e b

m 0 0 0 0 u _

N 1 1 1 1 g 1 1 1 1 n 7 7 7 7 i 5 5 5 5 w 2 2 2 2 .

a - - - -

r C C C C D M M M M m$5 B B B E _

2 _

T _

I r N _

e U -

b m -

u J N A 7 8 7 2 E

R

% e 2 2 6 5 I l

v - - - - U l

a W

F W

F W

F W G c

F V 2 2 2 2 M

MC-2571-1.0 VALVE: 2FW-27A CATEGORY: B CLASS: B FUNCTION: Isolates low pressure inj. from RWST.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Closure of this valve would render all low pressure injection inoperable.

ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

O O

McGUIRE - UNIT 2 II.33-4

SYSTEM: RESIDUAL HEAT REMOVAL SYSTEM FLOW DIAGRAMS: MC-2561-1.0 t

i I

O I

l l

l l

McGUIRE - UNIT 2 II.34-1

O l

a v 2 o -

m e e e e e e e e e 4 3

R m m m m m m m m i i i i i i i i t t t t t t t t t 1 a e e e e 1

e e e e e l l H l l l l l l c c c c c c c c l y y y y y y y y a s c c c c c c c c u k d r . . . . . . . .

i a x x x x x x x x s m a a a a a a a a e e m m m m m m m m R R . . . . . . . .

c c c c c c c c

e e e e e e e e m s s s s s s s s e 0 0 0 0 0 t 0 0 0 s 6 6 6 6 6 6 1 1 y

S e3t5OM S S wSES C C eU$s* td$ X X T T T T T T T T m$I01s* N$ T C

T C C C H M C C C C y D r

t o

g e

a C X X O C

B X X X X X X e

l v

a A X X V

3 3 2 2 1 1 1 1 8 8 7 7 9 9 m3a0 oO - - - - - - - - - -

I 1

1 E 1 1 J D F 1 1 B L r

e b

m 0 0 0 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 1 1 1

_ g 1 1 1 1 1 1 1 1 1 1

- n 6 6 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 2 2 2 a - - - - - - - - - -

_ r C C C C C C C C C C D M M M M M M M M M M

.$U A A B B B B B B B B 2 T

I N

r U e

b -

m u C, E N A B A l

e v

B 1

D A

2 D

B 4

D 9

1 D

3 2

D 8

D 8

1 D

3 3

D 7

6 D

8 6

D RO I

U G

c a N N N N N N N N N N M V 2 2 2 2 2 2 2 2 2 2

n n ( *>

m w y , y System: Residual Heat Removal E $ 6_

m 0 E O B 2 *

?  %

a  ?

G  % 5

$ $ Valve Category y d g 0

o 0 -- $ tE $

Valve Number Drawing Number A B C D Remarks 2ND-71 B MC-2561-1.0 C-4 X MT X RF

~2ND-14 B MC-2561-1.0 D-3 X CT 60 sec. max. cycle time 2ND-70 B MC-2561-1.0 K-3 X MT X RF 2ND-58A B MC-2561-1.0 K-3 X CT X CS 60 sec. max. cycle time 2ND-29A B MC-2561-1.0 J-3 X CT 60 sec. max. cycle time 2ND-15B B MC-2561-1.0 E-3 X CT 10 sec. max. cycle time 2ND-30A B MC-2561-1.0 I-3 X CT 10 sec. max. cycle time 2ND-34 B MC-2561-1.0 G-5 X CT 60 sec. max. cycle time McGUIRE - UNIT 2 II.34-3

1 MC-2561-1.0 VALVE: 2ND-1B, 2ND-2A CATEGORY: A CLASS: A FUNCTION: Provides suction for Residual Heat Removal pumps during normal cooldown.

TEST REQUIREMENT: Verify proper valve movement every three months.

BASIS FOR RELIEF: These valves have been provided with an interlock which prevents their opening when the Reactor Coolant System pressure is greater than 385 psig.

ALTERNATE TESTING: Valve will be cycled during cold shutdowns.

O i

1 O II.34-4 McGUIRE - UNIT 2 i

l MC-2 561-1. 0 VALVE: 2 ND-70 i

CATEGORY: C l

} CLASS: B FUNCTION: RHR to SI Suction Check.

TEST REQUIREMENT: Full stroke exercise quarterly.

1 4

4 BASIS FOR RELIEF: 2ND-70 cannot be full stroked during power operation or cold shutdown since the only full flow path is into l the RCS and this can only be performed during refueling outages when the reactor head is removed.

! ALTERNATE TESTING: 2ND-70 will be full stroke exercised at refueling and i partial stroked quarterly.

1 i

l i

i

+

i 1

1 4

l 4

l (NIs j McGUIRE - UNIT 2 11.34-5 e, w -

p m -w w n - - , - , 4 e - y y e-e,y- , , , - , ,-w7- n ,-- e, y-- ,--- - - . , - , - - - -,n,y- w-,- - - ,, e-,-,, - ,

l MC-2561-1.0 VALVE: 2ND-58 CATEGORY: B CLASS: B FUNCTION: Provides suction to the Centrifugal Charging Pumps from the Residual Heat Removal System.

TEST REQUIREMENT: Cycle valve every three months.

BASIS FOR RELIEF: Due to interlocks in the Safety Injection System and the actual Residual Heat Removal System design, it is impossible to test these valves without rendering both trains of Residual Heat Removal and both trains of Safety Injection inoperable during operation.

ALTERNATE TESTING: Cycle and time at cold shutdown.

O O

l II.34-6 McGUIRE - UNIT 2

I MC- 2561-1. 0 VALVE: 2ND-71 +

CATEGORY: C CLASS: B FUNCTION: RHR to SI Suction Check. .

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valve cannot be full stroked at power since the only full flow path is into the RCS,and this can only be done with the reactor head removed at refueling.

2ND-71 cannot be partial stroked during power since the required valve lineup would render both trains of safety injection inoperable. During cold shutdown, both SI pumps are tagged out to prevent a low tempera-ture overpressurization.

j ALTERNATE TESTING: Valve will be full stroked at refueling. .

W

?

l McGUIRE - UNIT 2 11.34-7

., r (Nj/ .

l

i I SYSTEM: SAFETY INJECTION 4 FLOW DIAGRAMS: MC-2562-1.0 ,

l MC-2562-2.0 i MC-2562-2.1 MC-2562-3.0

MC-2562-3.1 MC-2562-4.0 i

h i

it I

I t

l 1,

j 1

i l

t i

i j

i I

f McGUIRE - UNIT 2 II.35-1 J

- - -n --, -- . - - -. , w

$ t System: Safet.y injection E $ E 8  : a a a  ? "

%  ? a 4 a ~ E

$ 2 Valve Category u j U M 0 $ Y $

Valve Number Drawing Number A B C D H " H Remarke 2NI-9A B MC-2562-1.0 11-12 X CT X CS 10 sec. max. cycle time 2NI-108 B MC-2562-1.0 G-12 X CT X CS 10 sec. max. cycle t.ime 2NI-12 B MC-2562-1.0 G-9 X HT X RF 2NI-15 A MC-2562-1.0 K-7 X MT X RF 2NI-17 A MC-2562-1.0 I-4 X MT X RF 2NI-347 A MC-2562-1.0 I-4 X HT X RF 2NI-19 A MC-2562-1.0 F-4 X MT X RF 2NI-348 A MC-2562-1.0 F-4 X MT X RF 2NI-21 A MC-2562-1.0 C-7 X MT X RF 2NI-349 A "C-2562-1.0 C-7 X MT X RF McGUIRE - UNIT 2 II.35-2 O O O

O D O. y N] N]

$ t System: Safety Injection 5 0 E-B  : e4 a  ?

? e <

5 a ~ F 3  ? Valve Category u j t 3 E Y E Valve Number O Drawing Number u -A B C D H su H Remarks 2NI-354 A MC-2562-1.0 K-7 X MT X RF 2NI-431B B HC-2562-2.0 J-4 X CT X CS 60 sec. max. cycle time 2NI-70 A MC-2562-2.0 H-13 X X LT X CS MT RF 2NI-71 A MC-2562-2.0 H-14 X X LT X CS Pfr RF 2NI-430A B HC-2567-2 9 E-4 X CT X CS 60 sec. max. cycle time 2NI-59 .A MC-256b2.0 D-13 X X LT X CS MT RF 2NI-60 A MC-2562-2.0 D-14 X X LT X CS MT RF McGUIRE - UNIT 2 11.35-3 I

il lllll'

_ i n

o 4

5 O

_ t c c 3 c e e e s s 1 j 1 n 5 0 1

I 1

- y e

_ t s e e k m m f r i i a a t t S m e n n R o o

i i m t t e a a t l l s o o y s s S I I

$ 63% w2u o F R

SF CR SF CR S

C S

C

.8 ?* % 3o* X X X X X TT TT TT TT TT TT TT

{E82l* u o" CL ML LM LM ML NL CL y D r

o t

g e

a C X X X X X O C

B e

l v

a A X X X X X X X V

1 5 3 3 3 8 8 1 82tgo" - - - - - - -

K K C C C C F r

e .

b m 0 0 1 1 1 1 1 u . . . . .

N 2 2 2 2 2 2 2 g 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 a - - - - - - -

r C C C C C C C D M H M M M M M

.. a B B A A A A B 2

T I

N r U e -

b m E u R N A A O

I 7 8 1 2 3 4 5 U e 4 4 8 8 9 9 9 G v - - - - - - - c l I I I I I I I M

a N N N N N N N V 2 2 2 2 2 2 2 1ll l

7"N /N ;G, t

i 3 t System: Safety Injection E O E

! E E E a  ?

%  ? E 3 E ~  ?

E 3 Valve Category a j j O

o E

u E Y E

Valve Number Drawing Number A B C D H H Remarks 2NI-96B B MC-2562-2.1 E-14 X CT Isolation time $10 sec.

LT 2NI-436 B HC-2562-2.1 G-11 X X MT X RF* Passive LT 2NI-334B B HC-2562-3.0 L-11 X CT 10 sec. max. cycle time 2NI-333B B MC-2562-3.0 L-12 X CT 10 sec. max. cycle time 2NI-332B B MC-2562-3.0 L-14 X CT 10 sec. max. cycle time 2NI-136B B MC-2562-3.0 C-14 X CT 10 sec. max. cycle time 2NI-103A B MC-2562-3.0 I-14 X CT 10 sec. max. cycle time a

~2NI-101 B MC-2562-3.0 F-14 X MT X

+^

McGUIRE - UNIT 2 II.35-5

$ Il System: Safety injection E $ E 8 5 5 5 a  ?

? a

  • 3 a -  ?

E 2 Valve Category u 3 Il 3 8 o

5 H

Y H

Valve Number Drawing Number A B C D Remarks 2NI-100B B MC-2562-3.0 F-13 X CT X CS 10 sec. max. cycle time 2NI-135B B MC-2562-3.0 E-14 X CT 10 sec. max. cycle time 2NI-114 B MC-2562-3.0 I-9 X MT 2NI-115B B MC-2562-3.0 11 - 9 X CT 10 sec. max. cycle time 2NI-147A B MC-2562-3.0 G-11 X CT X CS 10 sec. max. cycle time 2NI-144B B MC-2562-3.0 G-9 X CT 10 sec. max. cycle time 2NI-143 B MC-2562-3.0 F-9 X MT 2NI-116 B MC-2562-3.0 J-9 X MT X RF 2NI-148 B MC-2562-3.0 D-9 X MT X RF 2NI-118A B MC-2562-3.0 11 - 7 X CT 10 sec. max. cycle time II.35-6 McGUIRE - UNIT 2 O O O

-- - ._ . . _ _ __ ___ _ _ _ .._m . . . _ . _ . _ . . _ _ _

e j t System: Safety Injection 5 3 8 8

a  ? *

? E 3 e ~  ?

E y Valve Category y j j M

o o 0

H E T M P E

Valve Number Drawing Number A B C D Remarks 2NI-150B B MC-2562-3.0 E-7 X CT 10 sec. max. cycle time 2NI-120B B MC-2562-3.0 J-7 X CT Isolation time $10 sec.

LT 2NI-121A B MC-2562-3.0 J-6 X CT Isolation time $10 sec.

2N1-122B B MC-2562-3.0 K-4 X CT Isolation time $10 sec.

_A 2NI-128 A MC-2562-3.0 I-4 X X LT X RF MT 2NI-134 A MC-2562-3,0 H-4 X X LT X CS Mr 2NI-129 A MC-2562-3.0 I-3 X X LT X CS MT 2NI-124 A MC-2562-3.0 1-3 X X LT X RF MT

< McGUIRE - UNIT 2 I I .3 5-7

$ Y System: Safety Injection E O E

4  ?

%  ? a 3 a ~  ?

2 Valve Category u 3 U 3 8  :

T Valve Number Drawing Number A B C D Remarks 2NI-126 A MC-2562-3.0 J-2 X X LT X CS MT 2NI-183B B MC-2562-3.0 G-3 X CT 20 sec. max. cycle time 2NI-152B B MC-2562-3.0 D-6 X CT 10 sec. max. cycle time 2NI-159 A MC-2562-3.0 B-4 X X MT X RF LT 2NI-160 A MC-2562-3.0 B-3 X X MT X RF LT 2NI-156 A MC-2562-3.0 D-3 X X LT X RF MT 2NI-157 A MC-2562-3.0 D-2 X X LT X RF MT 2NI-125 A MC-2562-3.0 I-3 X X LT X CS MT McGUIRE - UNIT 2 II.35-8 O O O

O v

Ov OL v

s 0 U System: Safety Injection

@ 0 E S E e a  ? #

  1. ? a 3 & -  ?

E 7. Valve Category u .E U M 8 0 Y $

Valve Number Drawing Number A B C D Remarks 2NI-162A B MC-2562-3.1 K-11 X CT X CS 10 sec. max. cycle time 2NI-171 A HC-2562-3.1 J-7 X X MT X RF LT 2NI-169 A MC-2562-3.1 J-6 X X MT X RF LT 2NI-167 A MC-2562-3.1 J-5 X X MT X RF LT 2NI-165 A MC-2562-3.1 J-3 X X MT X RF LT 2N1-173A B MC-2562-3.1 1-12 X CT 10 sec. max. cycle time 2NI-175 A MC-2562-3.1 1-8 X X MT X CS LT McGUIRE - UNIT 2 II.35-9

i t

n o

e m

e m

e m

e m e 0

1 5

3

- 9 c i i i i m e t t t t i 1 j t 1 n e e e e I l l l l e c c cy c l y y y y c t s c c c c y e k c f r . . . .

a a x x x x x

S m a a a a e m m m m a R m m c c c c .

e e e e e c t s s s s e s s y 0 0 0 0 S 1 6 6 1 3 S S S F F UE0d* ? g$ C C C R R 0 ?a ~.j$ X X X X X TT T TT TT T T T T E$Sa?& g$ ?L C tL l

ML C C C C y D r

o t

C g

e a

C X X X X X X X 0

B X e

v l

a A X X X V

2 2 2 2 8 ud,u 8 1 6 5 1 1 1 1 1

1 F F F D B C F r

e b

m 1 1 1 1 1 1 0 0 u . . . . . .

N 3 3 3 3 3 3 4 4 g 2 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 5 w 1 2 2 2 2 2 2 2 a - - - - - - - -

r C C C C C C C C D M M M  !

? M  !

? H  !

t 2

Eb" A B A A B B B B T

I N

U r

e -

b m E u B B A A B i l

N 6 8 0 1 4 5 8 4 l l

e v

a 7

1 I

N 7

1 I

N 8

1 I

N 8

1 I

N 8

1 I

N 8

1 I

N 5

3 I

N 4

2 I

N U

G M

c 0 V 2 2 2 2 2 _ 2 2 2

O O O V V V e

0 Il System: Safety Injection E $ E B

0  ? O a a

  • 3 a -  ?

E 13 Valve Category u $ Ij M 8 E Y E Drawing Number F* "' H Remarks Valve Number A B C D 2NI-242B B MC-2562-4.0 E-8 X CT 3 sec. max. cycle time 2NI-245A B MC-2562-4.0 F-7 X CT 3 sec. max. cycle time 2NI-243A B HC-2562-4.0 E-7 X CT 3 sec. max. cycle time 2N1-258 B MC-2562-4.0 F-5 X CT 10 sec. max. cycle time 2NI-255B B MC-2562-4.0 F-5 X CT 10 sec. max. cycle time 2NI-248 A MC-2562-4.0 E-5 X X LT X MT 2NI-249 A MC-2562-4.0 E-3 X X LT X MT 2NI-266A . A MC-2562-4.0 E-3 X CT Isolation time <10 sec.

LT 2NI-267A A MC-2562-4.0 E-4 X CT Isolation time <10 sec.

LT McGUIRE - UNIT 2 II.35-11

i n

o .

2 1

5 O

t c . 3 c e c e s e 1 j p 1 n 0 s i 1

$ h y

t s e c e k m e f r i t a a t r

S m e e n p R o

i m t d e a e t l t s o s y s e S I T

$ 63Q aSg$ F F F F R R R R

$8?"t3$ X X X X

  • $%1?* g0 T TT TT TT LM TT LM TT LM L CL LM y D X r

o g

e t

a C X X X X X O

C B

e l

v a A X X X X X V

2 3 6 4 3 2 8

%57 ou G G C C

C C I r

e b

n 0 0 0 0 0 0 0 w

N 4 4 4 4 4 4 4 g 2 2 2 2 2 2 2 n 6 6 6 6 6 6 6 i 5 5 5 5 5 5 5 w 2 2 2 2 2 2 2 a - - - - - - -

r C C C C C C C D M M M M M M M

- 2 mgU B B A A A A B T

I N

U r

e e -

b r m u E u t p R O

N 6 4 3 2 1 0 I 3 6 5 5 5 5 u U e 3 2 2 2 2 2 R G v - - -

I I

i s c c l I I I I N N M a N N N N l l i V 2 2 2 2 2 2 UD

I d

t f

MC-2562-1.0 i f

I VALVE: 2NI-9A, 2NI-103 l

CATEGORY: B t

CLASS: B l

FUNCTION: Isolate NV Charging Pumps discharge from the safety ,

injection lines.  ;

TEST REQUIREMENT: Cycle time quarterly BASIS FOR RELIEF: Opening either of these valves would increase the l charging flow into the Reactor Coolant System,  !

resulting in an increase of pressure and a rapid I change in the boron concentration. This would l create a transient and a possible shutdown.

ALTERNATE TESTING: Valve will be cycle timed at cold shutdowns.  !

i e

f t

f i

i I

r I

I e

l l

I McGUIRE - UNIT 2 11.35-13 i

I 1

l MC-2562-1.0 l VALVE: 2NI-15, 2NI-354, 2NI-17, 2NI-347, 2NI-19, 2NI-348, 2NI-21, 2NI-349 CATEGORY: C CLASS: A FUNCTION: Opens on flow from BIT.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Full or partial stroke during power operation would result in thermal shock to injection nozzles. Valve cannet be stroked during shutdown due to possible low temperature overprecsurization.

ALTERNATE TESTING: Valve will be full stroked at refueling.

O O

McGUIRE - UNIT 2 II.35-14

O B MC-2562-1.0 VALVE: 2NI-12 CATEGORY: C CLASS: B FUNCTION: Opens on flow from BIT.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Full or partial stroke during power operation would result in thermal shock to injection nozzles. Valve cannot be stroked during shutdown due to possible low temperature overpressurization.

ALTERNATE TESTING: Valve will be full stroked at refueling.

O i

i a

l O

I McGUIRE - UNIT 2 II.35-IS

MC-2562-2.0 VALVE: 2NI-430A, 2NI-431B CATEGORY: B CLASS: B FUNCTION: Supplies air to low pressure PORV's during blackout.

TEST REQUIREMENT: Cycle time quarterly.

BASIS FOR RELIEF: Valves are interlocked closed when RCS temperature is above 300 F.

ALTERNATE TESTING: Valves will be cycle timed at cold shutdown.

O O

McGUIRE - UNIT 2 II .35- 16

j MC-2562-2.0

) VALVE: 2NI-48 ,

, CATEGORY: A, C

! CLASS: B l

FUNCTION: Provides containment isolation.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valve has no indication of closure.

, ALTERNATE TESTING: Valve will be verified shut by leak test performed i in accordance with Appendix J.

9 i

i i,

'i i

t 9

McGUIRE-- UNIT 2 II.35-17

MC- 2562-2.0 1 MC- 2562-2.1

(+ O VALVE: 2NI-81, 2NI-70, 2NI-59, 2NI-93 CATEGORY: A, C CLASS: A FUNCTION: Opens on flow from the NI cold leg accumulator to the

~

Reactor Caclant System.

TEST REQUIREMENT: Verify valve opens when Reactor Coolant System pressure decreases below Safety Injection System pressure.

BASIS FOR RELIEF: Valves cannot be full or partial stroked during power operation since the accumulator pressure is % 425 psi and cannot overcome RCS pressure. During cold shutdown exercising these valves could result in a low temperature overpressurization of the RCS.

ALTERNATE TESTING: Valves will be partial stroked during cold shutdowns, but not more often than once per nine months. Valves will be full stroked at refueling.

1 O

D McGUIRE - UNIT 2 II.35-18

_ - _ . .. - - . _= -- - . - ._ -

t

MC-2562-2.1 i

i

! VALVE: 2NI-436 CATEGORY: A, C CLASS: B

FUNCTION: Provides containment isolation.

! TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valve has no indication of closure.

ALTERNATE TESTING: Valve will be verified shut by leak test performed in accordance with Appendix J.

l 1

5 k

1 1

i l

O i i McGUIRE - UNIT 2 11.35-19

4 MC-2562-2.0 MC-2 562-2.1 VALVE: 2NI-82, 2NI-71, 2NI-60, 2NI-94 CATEGORY: A, C CLASS: A FUNCTION: Opens on flow from the NI System to the Reactor Coolant System.

TEST REQUIREMENT: Verify valve opens when Reactor Coolant System pressure decreases below Safety Injection System pressure.

BASIS FOR RELIEF: Valves cannot be full or partial stroked at power since a driving head to force the valves open does not exist.

ALTERNATE TESTING: Valve will be full stroked during cold shutdowns, but no more often than once per nine months.

j ,

McGUIRE - UNIT 2 11.35-20 O l( .

1

MC-2562-3.0

, , i VALVE: 2NI-101  !

t CATEGORY: C i

CLASS: B 4 FUNCTION: Opens on flow from RWST to SI. ,

j TEST REQUIREMENT: Full stroke exercise quarterly. {

BASIS FOR RELIEF: Valve cannot be full stroked at power since the SI  ;

pumps cannot overcome RCS pressure. During cold l

, shutdown this valve cannot be full stroked since  !

this could result in a low temperature overpressuri- l zation.  ;

i I

ALTERNATE TESTING: Valve will be partial stroked quarterly and full stroked at refueling. I

, l f

+

1  ;

l 5  !

(

f i

. I i

i

+

i

?

l i

b McGUIRE - UNIT 2 II.35-21 I

I s

,, - - , < - ~ -,n , , --

,.--nc,. - - , < - . , - , -- - -

MC.2562-3.0 C

VALVE: 2NI-100B, FWST to Safety Injection Pumps CATEGORY: B CLASS: B FUNCTION: Isolates Safety Injection Pump Suction from FWST.

TEST REQUIREMENT: Cycle and time Valve Quarterly.

BASIS FOR RELIEF: Failure of valve in closed position would isolate suction from FWST to both safety injection pumps.

This would render both trains of SI inoperable.

ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

{

l O

McGUIRE - LTIT 2 II.35-22

i J

^

l

\ MC-2562-3.0 I

i VALVE: 2NI-147A Safety Injection Pumps Miniflow Header j to W CATEGORY: B 1

I CLASS: B 1

f FUNCTION: Isolation valve for safety injection miniflow to WST.

l TEST REQUIREMENT: Cycle and time valve quarterly.

BASIS FOR RELIEF: If valve fails in closed position, the recirculation flow path for the safety injection pumps is isolated. If a safety injection signal occurs with NC system pressure

! above shutoff head for the pumps, the pumps would not have a flow path. This would result in damage to the pumps.

ALTERNATE TESTING
Valve will be cycled and timed at cold shutdown.

l i

i i

i i

)

4

!l 4

O l l

McGUIRE - UNIT 2 II . 35-23

MC-2562-3.0 VALVE: 2NI-ll6, 2NI-148 CATEGORY: C CLASS: B FUNCTION: Opens on flow from the NI Pump (s).

TEST REQUIREMENT: Verify proper valve movement once per'three months.

BASIS FOR RELIEF: Valves cannot be full or partial stroked during power operation since the safety injection pumps cannot overcome RCS pressure. Valves cannot be stroked at cold shutdown since this could result in a low tem-perature overpressurization.

ALTERNATE TESTING: Valve will be cycled open during refueling.

i l

McGUIRE - UNIT 2 II.35-24 7

i,

N MC-2562-3.0 VALVE
2NI-128, 2NI-159, 2NI-160, 2NI-156, 2NI-124, 2NI-157 l

t CATEGORY: C CLASS: B FUNCTION: Provide containment isolation.

TEST REQUIREMENT: Verify proper valve movement once per three months.

BASIS FOR RELIEF: Valves cannot be full or partial stroked during power operation since the safety injection pumps cannot discharge into the RCS at operating pressure. During cold shutdown, these valves cannot be full or partial stroked since this could result in low temperature j overpressurization.

ALTERNATE TESTING: Valves will be cycled open during refueling.

e 2

l m

U l@

McGUIRE - UNIT 2 II.35-25

MC-2562-3.0 C

VALVE: 2NI-129, 2NI-125, 2NI-134, 2NI-126 CATEGORY: C CLASS: A FUNCTION: Opens on flow from the NI to NC Systes.

TEST REQUIREMENT: Verify valve opens on flow from safety injection pumps once per three months.

BASIS FOR RELIEF: The discharge pressure of the safety injection pumps (1520 psig) is not sufficient for opening the valve to the Reactor Coolant System (2235 psig) during power operation.

RHR pumps, also, do not develop enough discharge pressure to overcome RCS pressure at power operation.

ALTERNATE TESTING: Valve will be full stroke exercised during cold shutdowns, but not more often than once per nine months.

l l

O~

McGUIRE - UNIT 2 11.35-26 1

l i

i

! I l

4 MC-2562-3.1 ,

1 1

VALVE: 2NI-162A Safety Injection Pumps Cold Leg Inj. Header CATEGORY: B CIJ.:,S : B FUNCTION: Provides isolation of Safety Injection Pumps from cold legs during hot leg recirculation.

TEST REQUIREMENT: Cycle and time valve quarterly.

BASIS FOR RELIEF: Failure of valve in closed position would completely isolate both trains of safety injection during the initial injection phase.

ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

l i

i McGUIRE - UNIT 2 II .35- 27 I

l

MC-2562-3.1 VALVE: 2NI-165, 2NI-167, 2NI-169, 2NI-171 CATEGORY: A, C CLASS: A FUNCTION: SI discharge check valves.

TEST REQUIREMENT: Full stroke exercise quarterly.

BASIS FOR RELIEF: Valves cannot be cycled during power operation since the SI pumps cannot overcome RCS pressure to permit flow through the valves. Durir.g cold shutdowns exercising these valves could result in low tempera-ture overpressurization.

ALTERNATE TESTING: Full stroke exercise at refueling.

O i

I l

l l -

McGUIRE - UNIT 2 II.35-28 i

. _ _ _ , . _. -. -. . . - . = . _ - . ._. - ._ . . _ .. . -. .

i i

[ MC-2562-3.1 i

I l

i VALVE: 2NI-180, 2NI-181, 2NI-175, 2NI-176 CATEGORY: A, C l

1 i

CLASS: A FUNCTION: Opens on flow from the ND or NI to NC System.

1

] TEST REQUIREMENT: Verify valve opens on flow from NI or ND System to

the NC System once per three months.

4 BASIS FOR RELIEF: The discharge pressure of the NI and ND Pumps is not

, sufficient for opening the valve to the Reactor Coolant System during power operation.

ALTERNATE TESTING: Valve will be tested for proper movement during cold shutdowns, but not more often than once per nine months.

I i

! \

d i

a 1

i i

~p i

o.

.McGUIRE --UNIT 2 II . 35-29 l

4 3 l, MC-2563-3.1 VALVE: 2NI-184, 2NI-185 CATEGORY: B CLASS: B FUNCTION: Isolate the containment sump (2NI-184-isolates train B, i, 2NI-185 isolates train A). These valves also provide an

'i alternate source for suction to the Residual Heat Removal Pumps.

' BASIS FOR RELIEF: Due to interlocks in the Safety Injection System and the actual Residual Heat Removal design, it is impossible to test these valves without rendering both trains of Residual Heat Removal and both trains of Safety Injection inoperable. During cold shutdowns, the RHR pumps are required for decay heat removal.

i- -

ALTERNATE TESTING: Full stroke exercise during refueling.

l t

I l

l 5

McGUIRE - UNIT 2 II.35-30 1__--__-___--__

MC-2562-4.0 U

k.

l i

.l VALVE: 2NI-248, 2NI-249, 2NI-250, 2NI-251, 2NI-252, 2NI-253 l 1

CATEGORY: A, C I CLASS: A

! FUNCTION: Open when Reactor Coolant System pressure decreases below 1500 psig during accident conditions.

i TEST REQUIREMENT: Verify valves open on flow from upper head injection accumulator.

BASIS FOR RELIEF: The pressure in the UHI accumulator (1500 psig) is i not sufficient to open the valves into the Reactor ,

Coolant System (2235 psig). At cold shutdown, the high velocity water could cause damage to reactor internals. This, also, could cause low temperature overpressurization.

ALTERNATE TESTING: Valves will be full stroked at refueling by disassembly.

4

O C

l r

4 1

O O

McGUIRE - UNIT 2 II.35-31

SYSTEM: STATION AIR FLOW DIAGRAMS: MC-2605-2.2 l

l l

l O

McGUIRE - UNIT 2 II.36-1

c 2

6 3

- e e

r s 1 1

i A 5 l

n <

o i s e t k m a r i t a t S m e n R o

i m t e a t l s o y s S I

$gE a* y:H F R

F R

0 :a e ] ::cr X m 0a? :H TT CL TT HL y D e

r o

g e C X -

t a

C B

e v

l a A X X V

8 8 a% 8u F H

r e

b m 2 2 u

N 2 2 g 5 5 n 0 0 i 6 6 w 2 2 a - -

r C C D H H B B m au 2 T

I N

r U e

b -

m u E N B l

e v

a 2

1 S

V 3

1 S

V

- 8 G

M c

V 2 2

4 A

MC-2605-2.2 i

i l l j VALVE: 2VS-13 i

i CATEGORY: A, C l CLASS: B

} FUNCTION: Provide containment isolation.

l TEST REQUIREMENT: Verify proper valve movement once per three months.

I BASIS FOR RELIEF: The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING
Valve will be verified shut by leak test performed
in accordance with Appendix J.

.i I

i i

4

.i i

l

.i f

1 i

McGUIRE - UNIT 2 II.36-3 i

^

l s

1 i

SYSTEM: STREAM GENERATOR BLOWDOWN RECYCLE

! FLOW DIAGRAMS: MC-2580-1.0 1

i l

1 i

i l

i l

k i

1 1

1 l

i i

.1 l

4 4

i i

i l

i a

1 i

I l

O McGUIRE - UNIT 2 II.37-1

l lllll 1

e 2e l

c y

c -

e . . . .

c c

c

. 7 3

R c c c c e e e e e e e n s s s s s s s I I

w o 0 0 0 1

0 0 1

0 1

0 1

d 1 1 1 w $ 5 < $ $ $ $

o e e l s e e e e e B k m m m m m m m r i i i i i i i r a t t t t t t t o m t e n n n n n n n a R o o o o o o o r i i i i i i i e t t t t t t t a

n a a a a a a e l l l l l l l o

G o o o o o o s s s s s s s m I I I I I I I a

e S

t $t 0$" 4

$$EH m

e m N $ E" t m jY" s

y S

m$a0YE" T CQ T

CQ T

C9 T

CQ T

CQ T

CQ T

C0 uEH y D r

e o

g e C t

a C

B X X X X X X X e

l v

a A V

2 2 0 2 2 4 4 1 1 1 m0 $$O 1 1

F 1

1 F

1 1

. F 1

1 r

e b

m 0 0 0 0 0 0 0 u

N 1 1 1 1 1 1 1 g 0 0 0 0 0 0 0 n 8 8 8 8 8 8 8

' i 5 5 5 5 5 5 5 w 1 1 1 1 1 1 1 a - - - - - - -

r C C C C C C C D  !

? M M M M M M m$U B B B B B B B 2 T

I N

r U e

b -

n u

i E N R Ue I

e B A B A B A B v 1 5 2 6 3 7 4 G l - - - - - - - c a B B B B B B B _

M V B B B B B B B _

T f,f ll t l 1ll 1lll1 l ll (lll

i t O O

" system: Steam Generator Blowdown Recycle j

E B

3 U E m U S

? Valve Category a

u

~#

j@

Fj t." >

4 u

O 1?

Valve Number Drawing Number A B C D H MM H4 Remarks

BB-8A B MC-2580-1.0 F-10 X CT Isolation time $10 sec. ,

-Q BR-140A B MC-2580-1.0 D-2 X CT Isolation time $10 sec.

Q BB-141A B MC-2580-1.0 D,-4 X CT Isolation time 510 sec.

Q BB-142A B MC-2580-1.0 D-13 X CT Isolation time <10 sec.

9 BB-143A B MC-2580-1.0 D-10 X CT Isolation time $10 sec.

Q 4

i

.i McGUIRE - UNIT 2 II.37-3