Revised Application for Amend to License DPR-34,proposing Supplemental Changes to Administrative Controls Tech Specs Re Min Shift Crew Composition Requirements & Plant Operations Review Committee
ML20085J487
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 09/28/1983
From: Lee O
PUBLIC SERVICE CO. OF COLORADO
To:
Shared Package
ML20085J484 List:
References
NUDOCS 8310130200
Download: ML20085J487 (4)


Text

-

o

. +

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the Matter of the Facility Operating License)

)

of ) Dccket No. 50-267

)

PUBLIC SERVICE COMPANY OF COLORADO )

Application for Amendment to Appendix A of Facility Operating License License No. DPR-34 0F THE PUBLIC SERVICE COMPANY OF COLORADO FOR THE FORT ST. VRAIN NUCLEAR GENERATING STATION This application for Amendment to Appendix A of Facility Operating License, License No. DPR-34, is submitted for NRC review and approval.

Respectfully submitted, PUBLIC SERVICE COMPANY OF COLORADO By hD

0. R. Lee, Vice President KELLY, STANSFIELD & 0'DONNELL Bryant O'Donnell Robert E. Thompson Public Service Company Building Denver, Colorado 80202 Attorneys for Applicant 8310130200 830928 PDR ADOCK 05000267 P PDR

6 ATTACHMENT 1

SUMMARY

OF PROPOSED CHANGES

O'

SUMMARY

OF PROPOSED CHANGES Section Description Of Change AC 7.1.1 1) Reduced subsection headings from all capital letters to only first letter capitalized.

2) Added subsection 2.1. - sta'ff working guidelines.
3) Added subsection 3.c. - Technical Advisor qualifications.
4) Added Table 7.1-1 - Minimum Shift Crew Composition.
5) Changed Figure 7.1 Administrative and i

Departmental Management Organization Chart.

6) Changed Figure 7.1-2 - Conduct of Operations Chart AC 7.1.2 1) Reduced subsection headings from all capital letters to only first letters capitalized.
2) Subsection 1 revised PORC membership.

AC 7.1.3 1) Reduced subsection headings from all capital letters to only first letters capitalized.

2) Subsection 2 - revised the title of one NFSC member.

i

3) Subsection 7.b.(5) -

revised audit frequency _of the facility Emergency Plan and inplementing procedures.

4) Subsection 7.b.(6) -

revised audit frequency of the facility Security Plan and implementing procedures.

AC 7.1.3 (cont.) 5) Subsection 7.b.(8) - clarified fire protection auditing requirements.

6) Change to Section 7.1.3.7.a(1) to clarify which safety significant changes the Nuclear Facility Safety Committee reviews. This change reflects current Fort St. Vrain practices which are Nuclear Regulatory Commission accepted.

Figure 7.1-2 Revised to reflect current organization.

AC 7.4.c.3 Revised to reflect current adminstrative responsibilities.

._ __ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ _ - _ - -