v. ,:

f]  !

~. .

BEFORE THE; ..

. UNITED STATES NUCLEAR REGULATORY COMMISSION D 1

.i i

l' In the Matter of the Facility. 0perating License)

')  ;

of )

)

.PUBLIC SERVICE COMPANY OF COLORADO )

Application for Amendment to Appendix A of the Facility Operating License, License No. DPR-34 OF THE PUBLIC SERVICE COMPANY OF COLORADO FOR THE FORT ST. VRAIN NUCLEAR GENERATING STATION This application for Amendment to Appendix A of the Facility Operating License, License No. DPR-34, is submitted for NRC review and approval.

Respectfully submitted, PUBLIC SERVICE COMPANY OF COLORADO By A. Clegg Crawford Vice President Nuclear Operations i l

KELLY, STANSFIELD & 0'DONNELL James K. Tarpey Mark A. Davidson Public Service Company Building l Denver, Colorado 80202 l

Attorneys for Applicant 1.

1 i

8910100242 990930 ,7 FDR ADOCK 0500g{b-g P  !

1

- - _ _ - _ - - _ _ . _ _ _ _ _ _ _ _ . . -- i

l l E L:c.  ; '-

l:. , , , ' ' . ,:

a --

2 4

'. , ~

ATTACHMENT 1 TO P-89382

SUMMARY

OF PROPOSED CHANGES l

1

}.

[" , ,

SUMMARY

OF PROPOSED CHANGES L .

l 1 J

l* > LC014.4.7 This is ' a new LCO that has been added to the current Technical Specifications .to provide additional ' protection if gaseous chlorine is used-on site.

This is very similar. to TSUP LCO 3.3.2.6, c.ilorine Detection and Alarm System'. The format has been . revised slightly,. and the intent and purpose are nearly identical to' TSUP LC0 3.3.2.6.

The APPLICABILITY has been modified for clarification.

'An Action Statement referring to a section that does not exist in the current Technical Specifications has been deleted.

The Basis for LCO 4.4.7 is identical to the Basis for TSUP 3.3.2 6, except that a phrase regarding the initiation of protective actions has been deleted for clarification.

LCO 4.4.8 This is a new LCO that has been added to the current Technical Specifications to provide additional assurance of Control Room habitability under all conditions.

This is very similar to TSUP LCO 3.7.9, ' Control Room Emergency Ventilation System' The format has been revised slightly, and the intent is nearly identical.

A clarification was added to the Action statement requiring the suspension of movement of IRRADIATED FUEL. The phrase 'in the PCRV' was added to clarify that under this Action statement, the movement of IRRADIATED FUEL outside'the PCRV need not stop.

The Basis for LCO 4.4.8 is nearly identical to the Basis for TSUP LCO 3.7.9, with three changes.

First, the reference to a' prefilter has been deleted from the first paragraph in the Basis.

Second, a stateme,nt that the 7-day Action time j specified in the Action section is consistent with l the LWR Standard Technical Specifications was added for explanation of the interval. Third, the phrase 'as required by plant operating procedures'  ;

was deleted from the last paragraph in reference to the control room door being closed.

SR 5.4.14 This surveillance is designed to ensure the operability of the chlorine detection and alarm system. This surveillance requirement is new to the current Technical Specifications, but is

jn:

nearly identical t'o TSUP SR 4.3.2.6.

The' clarification was added that this Surveillance )

4.4.7 Requirement applies only when LC0 is applicable.

l The Basis for SR 5.4.14 is similar to the Basis for TSUP SR 4.3.2.6. The only difference is the ~

.: addition of a reference to identify a specific section o f- the LWR Standard Technical Specifications.

SR 5.4.15 This surveillance is designed to ensure the operability of the control room.' emergency ,

ventilation system. This Surveillance Requirement is new to the current Te'chnical Specifications,

~

but is nearly identical to TSUP SR 4.7.9.

The Basis for SR 5.4.15 is similar to the Basis for TSUP SR 4.7.9. A statement was added that the Surveillance Requirements and SURVEILLANCE INTERVALS. specified are consistent with LWR Standard Technical Specifications. .Also, a discussion of the HEPA filter integrity following

, a fire, chemical release, and area painting was added to the Basis section.